Field bus connections Link structure DDL Link structure DDL, bus coupler. Brochure

Size: px
Start display at page:

Download "Field bus connections Link structure DDL Link structure DDL, bus coupler. Brochure"

Transcription

1 Brochure

2 2 Bus coupler with driver link structure DDL, S-design S-design Bus coupler with driver Field bus protocol: ControlNet / EtherNET/IP / MODBUS TCP / TCP/IP Stand-alone bus coupler link structure DDL, S-design S-design Stand-alone bus coupler Field bus protocol: PROFIBUS DP / CANopen / DeviceNet / Interbus-S / PROFINET IO 7 Accessories End plate Base plate Stand-alone bus coupler for DDL 13 Electrical connection technologies Connecting cable, Series CN2 Plug, M12x1, 5-pin, A-coded, straight Socket, M12x1, 5-pin, A-coded, straight for CANopen, DeviceNet screened 1 Socket, M12x1, Series CN2 Socket, M12x1, -pin, A-coded, straight 15 Socket, M12x1, Series CN2 Socket, M12x1, 5-pin, A-coded, straight for CANopen, DeviceNet 16 Socket, M12x1, Series CN2 Socket, M12x1, 5-pin, B-coded, straight screened for PROFIBUS DP 17 Socket, M12x1, Series CN2 Socket, M12x1, -pin, A-coded, straight 18 Plug, M12x1, Series CN2 Plug, M12x1, 5-pin, B-coded, straight screened for PROFIBUS DP 19

3 3 Data final plug, Series CN2 Plug, M12x1, 5-pin, A-coded for CANopen, DeviceNet 20 Data final plug (male), Series CN2 Plug, M12x1, -pin, B-coded for PROFIBUS DP 21 Protective cap M12x1 22

4 link structure DDL, S-design S-design Bus coupler with driver Field bus protocol: ControlNet / EtherNET/IP / MODBUS TCP / TCP/IP Ambient temperature min./max. +5 C / +50 C Protection class IP65 Operational voltage electronics 2 V DC Electronics voltage tolerance -20% / +20% Operating voltage, actuators 2 V DC Actuator voltage tolerance 0% / +10% Total current for actuators 3 A Data transfer bit 128 bit Number of solenoid coils max. 2 Max. power consumption per coil 0.2 ma Max. cable length 0 m Max. number of DDL participants 1 Number of inputs 128 Number of outputs 128 PortValve system Socket (female) D-Sub 25-pin Materials: Housing Stainless steel, Polyarylamide The delivered product may vary from that in the illustration. Technical Remarks Max. current in 0 V line: A You will find assignment schemes for the product in the operating instructions, or contact the nearest AVENTICS sales office. Field bus protocol Communication port Bus IN Communication port Bus OUT ControlNet BNC plug connector BNC plug connector EtherNET/IP MODBUS TCP TCP/IP Plug (male), M12, 5-pin, A-coded Plug (male), M12x1, 5-pin power supply DDL OUT Weight Part No. Plug (male), M12, -pin, A-coded Plug (male), M12, -pin, A-coded Socket (female), M12, 5-pin Socket (female), M12, 5-pin [kg] R Part No. Fig. Note Fig. 1 1) R Fig. 2-1) Manual (English) R The following operating instructions can be found in the Media Center for: ControlNet: R EtherNET/IP: R

5 link structure DDL, S-design S-design Bus coupler with driver Field bus protocol: ControlNet / EtherNET/IP / MODBUS TCP / TCP/IP 5 Fig. 1 1) Bus IN, M12x1, B-coded 2) Bus OUT, M12x1, B-coded 3) DDL, M12, 5-pin ) Power supply plug M12, -pin

6 6 link structure DDL, S-design S-design Bus coupler with driver Field bus protocol: ControlNet / EtherNET/IP / MODBUS TCP / TCP/IP Fig. 2 1) DDL, M12, 5-pin 2) Bus, M12x1, A-coded 3) Power supply plug M12, -pin

7 link structure DDL, S-design S-design Stand-alone bus coupler Field bus protocol: PROFIBUS DP / CANopen / DeviceNet / Interbus-S / PROFINET IO Ambient temperature min./max. +5 C / +50 C Protection class IP65 Operational voltage electronics 2 V DC Electronics voltage tolerance -20% / +20% Operating voltage, actuators 2 V DC Actuator voltage tolerance 0% / +10% Total current for actuators 3 A Data transfer bit 128 bit Max. cable length 0 m Max. number of DDL participants 1 Materials: Housing Aluminum, Stainless steel, Polyarylamide The delivered product may vary from that in the illustration. Technical Remarks Max. current in 0 V line: A You will find assignment schemes for the product in the operating instructions, or contact the nearest AVENTICS sales office. Field bus protocol PROFIBUS DP CANopen DeviceNet Interbus-S PROFINET IO Communication port Bus IN Plug (male), M12x1, 5-pin, B-coded Plug (male), M12x1, 5-pin, A-coded Plug (male), M12x1, 5-pin, A-coded Plug (male), M12x1, 5-pin, B-coded Socket (female), M12x1, -pin, D-coded Communication port Bus OUT Socket (female), M12x1, 5-pin, B-coded Socket (female), M12x1, 5-pin, A-coded Socket (female), M12x1, 5-pin, A-coded Socket (female), M12x1, 5-pin, B-coded Socket (female), M12x1, -pin, D-coded power supply DDL OUT Weight Part No. Plug (male), M12x1, -pin, A-coded Plug (male), M12x1, -pin, A-coded Plug (male), M12x1, -pin, A-coded Plug (male), M12x1, -pin, A-coded Plug (male), M12x1, -pin, A-coded Socket (female), M12, 5-pin Socket (female), M12, 5-pin Socket (female), M12, 5-pin Socket (female), M12, 5-pin Socket (female), M12, 5-pin [kg] R R R Part No. Fig. Note Fig. 1 1) R Fig. 3 1) R Fig. 5 1) Fig. 2 1) R Fig. - 1) II 3G Ex na IIB T Gc X The following operating instructions can be found in the Media Center for: PROFIBUS DP: CANopen: R DeviceNet: R Interbus-S: PROFINET IO: R

8 8 link structure DDL, S-design S-design Stand-alone bus coupler Field bus protocol: PROFIBUS DP / CANopen / DeviceNet / Interbus-S / PROFINET IO Fig. 1 1) bus IN, M12x1, B-coded 2) bus OUT, M12x1, B-coded 3) DDL, M12, 5-pin ) Power supply plug M12x1, -pin

9 link structure DDL, S-design S-design Stand-alone bus coupler Field bus protocol: PROFIBUS DP / CANopen / DeviceNet / Interbus-S / PROFINET IO 9 Fig. 2 1) bus IN, M12x1, B-coded 2) bus OUT, M12x1, B-coded 3) DDL, M12, 5-pin ) Power supply plug M12x1, -pin

10 10 link structure DDL, S-design S-design Stand-alone bus coupler Field bus protocol: PROFIBUS DP / CANopen / DeviceNet / Interbus-S / PROFINET IO Fig. 3 1) DDL, M12, 5-pin 2) Bus, M12x1, A-coded, 5-pin 3) Power supply plug M12x1, -pin

11 link structure DDL, S-design S-design Stand-alone bus coupler Field bus protocol: PROFIBUS DP / CANopen / DeviceNet / Interbus-S / PROFINET IO 11 Fig. 1) bus IN, M12x1, D-coded 2) Bus OUT, M12x1, D-coded 3) DDL, M12, 5-pin ) Power supply plug M12x1, -pin

12 link structure DDL, S-design S-design Stand-alone bus coupler Field bus protocol: PROFIBUS DP / CANopen / DeviceNet / Interbus-S / PROFINET IO Fig. 5 10,5 8, ,5 STATUS 5V MNS RUN 120, DDL DeviceNet XPD X7D X1S 1) 2) 3) ) DDL, M12, 5-pin 2) Bus, M12x1, 5-pin 3) Power supply plug M12x1, -pin

13 13 Accessories Base plate Stand-alone bus coupler for DDL Ambient temperature min./max. +5 C / +50 C Materials: Base plate Aluminum Weight Part No. [kg] 0.1 R scope of delivery incl. seal Dimensions ,

14 1 Accessories Connecting cable, Series CN2 Plug, M12x1, 5-pin, A-coded, straight Socket, M12x1, 5-pin, A-coded, straight for CANopen, DeviceNet screened Ambient temperature min./max. Protection class Wire cross-section -25 C / +80 C IP mm² Materials: Housing Housing color Seals Cable color Polyurethane Orange Fluorocaoutchouc Black Technical Remarks The specified protection class is only valid in assembled and tested state. Operational Max. current Cable length L Part No. voltage max. [V AC] [A] [m] Dimensions 5,5 L 3 M12x1 15, M12x1 13,5 6 13, L = cable length

15 15 Accessories Plug pin assignment Pin assignment, socket Stecker_A-Codiert Buchse_A-Codiert (1) BN=brown (2) WH=white 3) BU=blue () BK=black (5) GRN-Y=green-yellow Socket, M12x1, Series CN2 Socket, M12x1, -pin, A-coded, straight Ambient temperature min./max. Protection class -25 C / +90 C IP67 Materials: Housing Seals Polybutyleneterephthalate Fluorocarbon caoutchouc The delivered product may vary from that in the illustration Technical Remarks The specified protection class is only valid in assembled and tested state. Operational voltage Max. current suitable cable-ø min./ max Housing color Weight Part No. AC [V] [A] [mm] [kg] 8 / 8 Black Dimensions 52,5 Ø20 M12x1 SW

16 16 Accessories Pin assignment Buchse_A-Cod_-p Socket, M12x1, Series CN2 Socket, M12x1, 5-pin, A-coded, straight for CANopen, DeviceNet Ambient temperature min./max. Protection class -0 C / +85 C IP67 Materials: Housing Polyamide Technical Remarks The specified protection class is only valid in assembled and tested state. Operational voltage Max. current suitable cable-ø min./ max Housing color Weight Part No. AC [V] [A] [mm] [kg] 36 / 6 Black Dimensions M 12x1 Ø19,6 5 D0_002

17 17 Accessories Pin assignment Buchse_A-Codiert Socket, M12x1, Series CN2 Socket, M12x1, 5-pin, B-coded, straight screened for PROFIBUS DP Ambient temperature min./max. Protection class -25 C / +90 C IP67 Materials: Housing Seals Brass, nickel-plated Fluorocarbon caoutchouc Technical Remarks The specified protection class is only valid in assembled and tested state. Operational voltage Max. current suitable cable-ø min./ max Housing color Weight Part No. AC [V] [A] [mm] [kg] 8 / 9 silver Dimensions ~ 60 M12x1 Ø

18 18 Accessories Pin assignment Buchse_B-Codiert Socket, M12x1, Series CN2 Socket, M12x1, -pin, A-coded, straight Ambient temperature min./max. Protection class -25 C / +90 C IP67 Materials: Housing Seals Polybutyleneterephthalate Fluorocarbon caoutchouc The delivered product may vary from that in the illustration Technical Remarks The specified protection class is only valid in assembled and tested state. Operational voltage Max. current suitable cable-ø min./ max Housing color Weight Part No. AC [V] [A] [mm] [kg] 8 / 8 Black Dimensions 52,5 Ø20 M12x1 SW

19 19 Accessories Pin assignment Buchse_A-Cod_-p Plug, M12x1, Series CN2 Plug, M12x1, 5-pin, B-coded, straight screened for PROFIBUS DP Ambient temperature min./max. Protection class -25 C / +90 C IP67 Materials: Housing Seals Brass, nickel-plated Fluorocarbon caoutchouc Technical Remarks The specified protection class is only valid in assembled and tested state. Operational voltage Max. current suitable cable-ø min./ max Housing color Weight Part No. AC [V] [A] [mm] [kg] 8 / 9 silver Dimensions ~ 65 M12x1 Ø

20 20 Accessories Pin assignment, B-coded Stecker_B-Codiert Data final plug, Series CN2 Plug, M12x1, 5-pin, A-coded for CANopen, DeviceNet Ambient temperature min./max. Protection class +0 C / +60 C IP67 Materials: Housing Thermoplastic elastomer Technical Remarks The specified protection class is only valid in assembled and tested state. Cable exit Housing color Weight Part No. [kg] straight 180 Black Dimensions 5 1,5 M12x

21 Accessories 21 Pin assignment Stecker_A-Codiert Data final plug (male), Series CN2 Plug, M12x1, -pin, B-coded for PROFIBUS DP Ambient temperature min./max. Protection class -25 C / +80 C IP67 Materials: Housing Thermoplastic elastomer Technical Remarks The specified protection class is only valid in assembled and tested state. PROFIBUS DP bus termination plug Cable exit Housing color Weight Part No. [kg] straight 180 Black Dimensions Ø1,5 2 25,5 1 Ø1 M12x

22 22 Accessories Pin assignment Stecker_B-Cod_-p Protective cap M12x1 1, Ø8,5 M12 x 1 Ø Part No. Type Material Weight [kg] Order quantity [Piece] M12x1 Polyamide

23 AVENTICS GmbH Ulmer Straße Laatzen, GERMANY Phone Fax Find more contact information at Only use the AVENTICS products shown in industrial applications. Read the product documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When integrating the product into applications, note the system manufacturer s specifications for safe use of the product. The data specified only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that the products are subject to a natural process of wear and aging An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. AVENTICS S.à r.l. This document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS S.à r.l.. It may not be reproduced or given to third parties without its consent. PDF online

Field bus connections Link structure BDC Link structure BDC, B-design. Brochure

Field bus connections Link structure BDC Link structure BDC, B-design. Brochure Field bus connections, B-design Brochure Field bus connections, B-design Bus coupler with driver Direct field bus connection (BDC) Bus coupler with driver direct field bus connection Field bus protocol:

More information

Piston rod cylinder Guide cylinders Series MSN. Brochure

Piston rod cylinder Guide cylinders Series MSN. Brochure Brochure 2 ini slide, narrow version Ø 6-6 mm double-acting with magnetic piston cushioning: elastic with integrated ball rail guide 3 overview overview 9 Sensors and sensor mountings, accessories Sensor,

More information

Rodless cylinders Rodless cylinders Series RMC. Brochure

Rodless cylinders Rodless cylinders Series RMC. Brochure Brochure Bosch Rexroth AG Pneumatics -SB Ø 16-32 mm double-acting with magnetic piston Slide bearing guide cushioning: pneumatically, adjustable 4 -SB Ø 16-32 mm double-acting with magnetic piston long

More information

Gripper and vacuum technology Vacuum suction grippers Series SGN. Brochure

Gripper and vacuum technology Vacuum suction grippers Series SGN. Brochure ripper an vacuum technology Vacuum suction grippers Brochure 2 ripper an vacuum technology Vacuum suction grippers F = 1.5-35 N external iameter: 6.3-30 mm external threa 3 F = 1.5-35 N external iameter:

More information

Clamping Device, Series 2709

Clamping Device, Series 2709 Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Pneumatics Service Clamping Device, Series 2709 Technical data Pneumatic Open mechanism Technical Data Type Power transmission

More information

PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP

PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP FBP FieldBusPlug V6 PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP PDP21-FBP PROFIBUS DP FieldBusPlug PROFIBUS DP Fig. 1: PDP21-FBP Fig. 2: PDP21-FBP, plugged to the Universal Motor Controller UMC22-FBP

More information

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B Model Number Cable pull rotary encoder with PROFI- NET interface Features Robust aluminum drum housing Drum travel when cable retracted using threaded spindle Bellows with steel tip Comprehensive accessories

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Piston rod cylinders Standard cylinders ISO 15552, Series ICL. Brochure

Piston rod cylinders Standard cylinders ISO 15552, Series ICL. Brochure Brochure 2 Bosch Rexroth AG Pneumatics Profile cylinder, Ø 32-125 mm Ports: G 1/8 - G 1/2 double-acting with magnetic piston cushioning: pneumatically, adjustable Piston rod: external thread 4 Cylinder

More information

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7

More information

Control block CPX-CM-HPP

Control block CPX-CM-HPP Key features New options for controlling drive technology The control block CPX-CM-HPP makes all of Festo s electric drive technology compatible with all industrial communication interfaces. CPX-CM-HPP

More information

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376 Supplementary instructions Plug connector Harting HAN 8D for continuously measuring sensors Document ID: 30376 Contents Contents 1 For your safety 1.1 Appropriate use... 3 1.2 Impermissible use... 3 1.3

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

Fieldline. Fieldline Modular bus coupler, PROFIBUS, 8 digital inputs 24 V DC, M12 RF-FLM BK PB M12 DI 8 M12

Fieldline. Fieldline Modular bus coupler, PROFIBUS, 8 digital inputs 24 V DC, M12 RF-FLM BK PB M12 DI 8 M12 Modular bus coupler, PROFIBUS, 8 digital inputs 24 V DC, M12 RF-FLM BK PB M12 DI 8 M12 2 Bosch Rexroth AG Electric Drives and Controls Documentation Technical data Local bus interface Designation Local

More information

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1. Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page

More information

MAREX ECS DESIGNED TO PERFORM

MAREX ECS DESIGNED TO PERFORM MAREX ECS DESIGNED TO PERFORM 2 Marex ECS Design Design: A genuine eye-catcher on your bridge Excellent design supports operation in all situations. The straightforward, timeless style of the Marex ECS

More information

standard, short, preferential, top

standard, short, preferential, top ipf electronic gmbh Kalver Straße 27 standard design short design preferential series top series standard, short, preferential, top norm sensing ranges, increased sensing ranges 1100 1 2 1100 norm sensing

More information

Presented By. NicolScales.com Contact Us

Presented By. NicolScales.com Contact Us Presented By Dallas Ft Worth Austin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO Accredited Calibration Company that has provided calibration, repair and sales of

More information

Fieldbus Gateway Type ME43

Fieldbus Gateway Type ME43 Fieldbus Gateway Type ME43 Gateway for Industrial Ethernet and Fieldbus standards Up to 128 input and 128 output variables can be assigned Easy integration in the process control system ensured through

More information

Device Configurator ECI-1

Device Configurator ECI-1 Honsberg Instruments GmbH Tenter Weg 2-8 42897 Remscheid Germany Fon +49 (0) 2191-9672 - 0 Fax - 40 www.honsberg.com info@honsberg.com Device Configurator ECI-1 Handling and operation Connection The device

More information

HM Detailed data sheets for these products can be found on the Contrinex website:

HM Detailed data sheets for these products can be found on the Contrinex website: HM- Detailed data sheets for these products can be found on the Contrinex website: the contrinex network low frequency high frequency KEY ADVANTAGES ü Powerful RS network for LF and HF systems ü Threaded

More information

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv) Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface

More information

Industrial Hydraulics FAQs

Industrial Hydraulics FAQs Industrial Hydraulics FAQs FAQ Title: Z versus K or K0 in model code Category: Proportional & Servo Valves Sub-Category: Directional Control Valves Bosch Rexroth Corporation Hydraulics 5 City Line Road

More information

11 PROFIBUS Fieldbus Connector

11 PROFIBUS Fieldbus Connector 750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm 5 < 36,7mm < 372 mm < 54 mm < 36 mm / 42 in < 5-6 mm / 022 in < 0 mm / 0394 in The fieldbus connector links a PROFIBUS device

More information

Measuring modules CPX-CMIX

Measuring modules CPX-CMIX Key features At a glance Movement and measurement in one, as an integral component of the valve terminal CPX the modular peripheral system for decentralised automation tasks. The modular design means that

More information

Absolute encoders - modular bus covers

Absolute encoders - modular bus covers BMMH 58 flexible with blind hollow shaft Features Encoder single- or multiturn / bus cover Robust magnetic sensing Resolution: singleturn bit, multiturn 8 bit Modular fieldbus interfaces CANopen /DeviceNet/EtherCAT/EtherNet-IP

More information

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456 Supplementary instructions Plug connector Harting HAN 7D For point level sensors Document ID: 446 Contents Contents For your safety.... Appropriate use.... General safety instructions.... Safety instructions

More information

Fieldline. 4 digital inputs, 4 digital inputs/outputs RF-FLM DIO 8/4 M8

Fieldline. 4 digital inputs, 4 digital inputs/outputs RF-FLM DIO 8/4 M8 4 digital inputs, 4 digital inputs/outputs 2 Bosch Rexroth AG Electric Drives and Controls Documentation Technical data Local bus interface Designation Local bus M8 connector Supply for module electronics

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

Intelligent Positioning Drive GEL 6111 CANopen, PROFIBUS DP, Ethernet etc.

Intelligent Positioning Drive GEL 6111 CANopen, PROFIBUS DP, Ethernet etc. Intelligent Positioning Drive GEL 6111 CANopen, PROFIBUS DP, Ethernet etc. Technical Information Version 11.10 Features Nominal torque 5 Nm Self-locking system for wear-free holding torque On-board controls

More information

PROFIBUS Fieldbus Connector 634

PROFIBUS Fieldbus Connector 634 750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm < 36,7mm < 372 mm < 54 mm < 36 mm / 142 in < 5-6 mm / 022 in < 10 mm / 0394 in The fieldbus connector links a PROFIBUS

More information

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected

More information

Multipole and Fieldbus

Multipole and Fieldbus > Series 3 Plug-In valve islands Valve Islands > 016 Series 3 Plug-In valve islands, Multipole and Fieldbus New versions Plug-In system for Series 3 solenoid valves, G1/8 port. Valve functions: x3/, 5/

More information

PLIN-LWL Optical Coupler for LIN Data Transmission. User Manual. Document version ( )

PLIN-LWL Optical Coupler for LIN Data Transmission. User Manual. Document version ( ) PLIN-LWL Optical Coupler for LIN Data Transmission User Manual Document version 1.1.1 (2017-01-27) Relevant products Product Name Model Part number PLIN-LWL IPEH-004049 All product names mentioned in this

More information

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES Online data sheet i10-e0454 Lock i10 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i10-e0454 Lock 6045056 The actuator has to be ordered separately. See "Accessories"

More information

Temperature module. 4 inputs for thermocouples

Temperature module. 4 inputs for thermocouples 2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs, M12 Thermocouples (TC) M12 Technical data S67-AI4-UTH-M12 Local bus interface Designation System bus M12 connector, B-coded, 5-pin,

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6 Type designation Ident no. 1545030 Number of channels 6 Dimensions (W x L x H) 172 x 145 x 77.5 mm Cable max. 50 m between interface and read/write head 3 decimal rotary coding switches for the adjustment

More information

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10 Model Number Features Solid shaft 0 Bit multiturn Free of wear magnetic sampling High resolution and accuracy Mechanical compatibility with all major encoders with fieldbus interface Status LEDs Description

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive

More information

System Control Unit (SCU)

System Control Unit (SCU) ystem Control Unit (CU) Fieldbus coupler for Industrial Ethernet and Fieldbus standards Up to 28 input and 28 output variables can be assigned Easy integration in the process control system ensured through

More information

Distance and Position Sensors

Distance and Position Sensors Distance and Position Sensors SENSORS FOR DISTANCE AND POSITION Using various measuring techniques, HYDAC offers different distance and position sensors for a wide array of mobile and stationary applications.

More information

Part no.: CML720i-T R-M12 Light curtain transmitter

Part no.: CML720i-T R-M12 Light curtain transmitter Technical data Basic data Series 720 Operating principle Throughbeam principle Device type Transmitter Contains Accessories for the use of the BT-2R1 Application Object measurement Optical data Operating

More information

AS-Interface Bus Control System

AS-Interface Bus Control System AS-Interface Bus Control System Versatile system easily expandable Dedicated modules linked to Nugget Valve Islands Overall Fieldbus control achieved via gateway Complete range of accessories EMC compliant

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type 8695 can be combined with Compact stainless steel design Integrated analog valve position registration (Teach function) Coloured illuminated

More information

Standard PROFINET IO. RoHS. High shaft load capacity. High protection level. Flexible

Standard PROFINET IO. RoHS. High shaft load capacity. High protection level. Flexible The encoders Sendix 5868 and 5888 with PROFINET interface and optical sensor technology are ideal for use in all applications with PROFINET technology. The encoder supports the isochronous (IRT) mode and

More information

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W Duct Sensor CO₂ / Humidity / Temperature For combined measurement of CO₂, relative humidity and temperature in the duct. Dual channel CO₂ technology. The measured values are output via BACnet. NEMA 4X

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Mating connectors and cable sets for valves and sensors in hydraulics

Mating connectors and cable sets for valves and sensors in hydraulics Mating connectors and cable sets for valves and sensors in hydraulics RE 08006/0. Replaces: 04. /4 Table of contents See page to 5 Features Mating connectors and cable sets for the electrical connection

More information

Service case with test unit for servo-valves without integrated electronics

Service case with test unit for servo-valves without integrated electronics Service case with test unit for servo-valves without integrated electronics RE 29681/05.11 Replaces: 06.10 1/6 Type VT-SVTSY-1 Series 1X H6100_d Table of contents Contents Page Features 1 Ordering code

More information

Modular I/O system. Power module

Modular I/O system. Power module 2 Bosch Rexroth AG Electric Drives and Controls Documentation Supply module Connection: 1x M23 / 6x M12 The passive feed module is used to supply voltage to IndraControl S67 components. Thanks to options

More information

Transponder-coded. with guard locking

Transponder-coded. with guard locking Transponder-coded safety switch CTP with guard locking The safety switch CTP The new safety switch CTP combines the proven principle of operation of electromechanical safety switches with guard locking

More information

Automated Precision Weighing

Automated Precision Weighing Automated Precision Weighing Smart Load-Cell Technology The load cell, with Monobloc technology, is at the core of the SLF6-Series load cells and guarantees the highest precision and reliability. A robust

More information

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W Duct Sensor CO₂ / Humidity / Temperature Duct air quality sensor for combined detection of CO₂, relative humidity and temperature. Designed for control and monitoring applications. Type Overview Type Output

More information

Level and temperature switch Nivotemp NT-M, NT-MD

Level and temperature switch Nivotemp NT-M, NT-MD Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible

More information

Online data sheet. C4C-EB10530A10000 detec SAFETY LIGHT CURTAINS

Online data sheet. C4C-EB10530A10000 detec SAFETY LIGHT CURTAINS Online data sheet C4C-EB10530A10000 detec A B C D E F Ordering information Type Part no. C4C-EB10530A10000 1219563 Included with delivery with every device: 1 system connecting cable with flying leads

More information

Sensor Actuator Interface. Catalogue

Sensor Actuator Interface. Catalogue C T L O G U E 8 2011 2012 ensor ctuator Interface Catalogue CTLOGUE 8 ensor ctuator Interface Contents ensor ctuator Interface Introduction ensor and actuator cables Fieldbus, data cables and accessories

More information

M12x1 Circular Connectors

M12x1 Circular Connectors M12x1 Circular Connectors Agenda 1. Introduction M12x1 Circular Connectors 2. M12x1 X-coded 3. M12x1 D-coded 4. Accessories and Nomenclature 3 / 2015 Product Presentation M12x1 Page 2 M12x1 Circular Connectors

More information

Interfaces Service and Field

Interfaces Service and Field Interfaces Service and Field Front Panel Interfaces Interfaces Service Receptacles Cable Entry Systems 02 TRANSFORMATOREN 03 MODLINK MSDD THE CONNECTION TO THE OUTSIDE WORLD A safe bet MARKET REQUIREMENTS

More information

Product Information. Inductive Proximity Switches IN

Product Information. Inductive Proximity Switches IN Product Information IN IN Reliable. Non-contact. Easy assembly. Inductive proximity switches IN Inductive proximity switches are used to scan the current status of automation components. They are offered

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic

More information

Low frequency High frequency

Low frequency High frequency Low-frequency Technology Highlights: ü All-metal components for aggressive operating environments ü Embeddable transponders ü Transponders can be written to and read through metal ü Memory of transponders:

More information

More Precision. wiresensor // Draw-wire displacement sensors

More Precision. wiresensor // Draw-wire displacement sensors More Precision wiresensor // Draw-wire displacement sensors 24 Low-cost draw-wire displacement sensors wiresensor MK analog - Robust plastic housing - Customized versions for OEM - Potentiometer, current

More information

FIT 7A. Digital load cell dynamic weighing. Special features. Data sheet

FIT 7A. Digital load cell dynamic weighing. Special features. Data sheet FIT 7A Digital load cell dynamic weighing Special features - Accuracy class up to C4 and maximum scale interval factor Y up to 25,000 with OIML R60 test report - Off-center load compensated (OIML R76)

More information

LFC Liquid Flow Controller

LFC Liquid Flow Controller LFC Liquid Flow Controller Type 879 can be combined with High dynamic control through fast flow measurement Applicable for liquid dosing up to 600 ml/min (6 l/h) No moving parts in medium Fieldbus optional

More information

Product type designation. Control elements. Installation type/mounting

Product type designation. Control elements. Installation type/mounting Datasheet SIMATIC HMI KP32F PN, KEY PANEL, 32 SHORT-STROKE KEYS WITH MULTI-COLOR LED'S, PROFINET INTERFACES WITH PROFISAFE, 16DI+16DI/DO, 4 SAFETY DI PINS, 24V DC LOOP THROUGH CONFIGURABLE FROM STEP7 V5.5

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Digital electropneumatic Positioner for the integrated mounting on process

Digital electropneumatic Positioner for the integrated mounting on process Digital electropneumatic Positioner for the integrated mounting on process control valves Compact, robust stainless Steel design Easy start-up by automatic X-Tune function Contact-free position sensor

More information

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H VM series Cylindrical M2 in AC inductive sensors warranty features warranty Output: cable and M2 plug cable exit Models with 2 wires IP67 protection degree Multivoltage 20...253 Vac web contents Application

More information

07. har-link Interface Connectors

07. har-link Interface Connectors . Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

Bus Capable. Compact. Flexible. WSG Intelligent Gripper

Bus Capable. Compact. Flexible. WSG Intelligent Gripper WSG Bus Capable. Compact. Flexible. WSG Intelligent Gripper Servo-electric 2-finger parallel gripper with highly precise gripping force control and long stroke Field of Application A ll-purpose, ultra-flexible

More information

Fieldbus slave modules w/o I/Os

Fieldbus slave modules w/o I/Os tem SLIO Fieldbus slave modules w/o I/Os tem 500S tem 300S tem 100V Order number Figure Type IM 053CAN, CANopen slave IM 053DN, DeviceNet slave IM 053DP, PROFIBUS-DP slave IM 053EC, EtherCAT slave General

More information

User Manual Gateway component for EtherNet/IP

User Manual Gateway component for EtherNet/IP User Manual Gateway component for EtherNet/IP PR100066 1/7/2016 Table of Contents KUNBUS GmbH Table of Contents 1 General Information... 3 1.1 Disclaimer... 3 1.2 Notes Regarding this User Manual... 4

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

exlink Mining Electrical connectors for mining

exlink Mining Electrical connectors for mining exlink Mining Electrical connectors for mining I What is exlink? I What is exlink? exlink is a complete system for connecting and disconnecting products electrically. This system is available in different

More information

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet WTX120 Legal-for-trade industrial weighing terminal Special features - Connection of up to 8 SG load cells (350 ohm) via plug terminals - Display resolution up to 30,000, legal for trade up to 10,000e

More information

Linear Position Transducer HLT 1000-R2

Linear Position Transducer HLT 1000-R2 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and

More information

Valve island VM10 with EtherNet/IP Interface 8, 10, 12 or 16 stations. Operation & Service Manual

Valve island VM10 with EtherNet/IP Interface 8, 10, 12 or 16 stations. Operation & Service Manual Valve island VM10 with EtherNet/IP Interface 8, 10, 12 or 16 stations Operation & Service Manual Change history: The Change history reflects all changes of the, which were done after the initial release.

More information

RE 50220/ Type ABZMS-40. Component series 1X Maximum operating pressure 1 bar 1/10

RE 50220/ Type ABZMS-40. Component series 1X Maximum operating pressure 1 bar 1/10 Float switch with two switching contacts, two programmable switching outputs for temperature, alternatively one programmable switching output and one analog output with display and control unit E 50220/07.0

More information

07. har-link INTERFACE CONNECTORS

07. har-link INTERFACE CONNECTORS . INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

80265 series, 3/2 Indirect solenoid actuated poppet valve

80265 series, 3/2 Indirect solenoid actuated poppet valve > > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,

More information

Environmentally Sealed

Environmentally Sealed Weather-Pack 16 Metri-Pack 19 AMP Superseal 24 Ampseal 16 27 M12 Network 30 DIN Connectors 31 Schlemmer / Din Conduit Sealed 32 Schlemmer / Din Contact Sealed 34 Ideal for applications requiring protection

More information

red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection

red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection High accuracy for heavy duties: Mass Flow Meters & Controllers with IP67 & Ex Protection

More information

Analog input module. 4 inputs, voltage and current

Analog input module. 4 inputs, voltage and current 2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 inputs: M12, 0 to 20 ma, 4 to 20 ma, ±20 ma, 0 to 10 V, ±10 V Technical data S67-AI4-U/I-M12 Local bus interface Designation System bus M12

More information

M8/M12 Connector. PCA/EX9/EX500 Series. Reduction in wiring time. Conforming to IEC Fieldwireable Connectors

M8/M12 Connector. PCA/EX9/EX500 Series. Reduction in wiring time. Conforming to IEC Fieldwireable Connectors / Connector /EX9/EX00 Series Fieldwireable Connectors Reduction in wiring time The man-hours can be decreased because no exclusive tools (such as solder, crimped terminal) are required.also, the wire length

More information

Absolute encoders - modular bus covers Solid shaft with clamping or synchro flange Optical single and multiturn encoders 13 bit ST / 16 bit MT

Absolute encoders - modular bus covers Solid shaft with clamping or synchro flange Optical single and multiturn encoders 13 bit ST / 16 bit MT Features Encoder single- or multiturn / bus cover Optical sensing method Resolution: singleturn 13 bit, multiturn 16 bit Clamping or synchro flange CANopen /DeviceNet/EtherCAT/EtherNet-IP SAEJ1939/PROFINET/POWERLINK/Profibus/SSI

More information

ABSOLUTE ROTARY ENCODER INTERBUS

ABSOLUTE ROTARY ENCODER INTERBUS Main Features - Compact and heavy duty industrial model - Interface: Remote-Bus - ENCOM-Profile: K (programmable) - Housing: 58 mm - Shaft: 6 or 10 mm, hollow- 15 mm - Resolution: max. 25 Bit =,554,42

More information

Flow. Flow. N/en

Flow. Flow. N/en / poppet valves electromagnetic actuated, directly controlled G /4 or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to, 0 - mbar For a.c. solenoid systems with integrated

More information

MPreC - Pressure Relief Device Order specification sheet

MPreC - Pressure Relief Device Order specification sheet - Pressure Relief Device Order specification sheet -Series LARGE MESSKO PRESSURE RELIEF DEVICE Complete the Order-N o by choosing the specific add-on s: e.g.: LMPRD 685-08-22-N01-00 Order-N o : Parameter

More information

Inductive displacement measurement system model series IE25P with programmable analogue interface

Inductive displacement measurement system model series IE25P with programmable analogue interface Inductive displacement measurement system Document No.: IE 12781 BE Date: 05.01.16 Contactless, wear-free sensor system Analogue interface Measuring range programmable Measuring range up to 0 mm Stainless

More information

More Precision. wiresensor // Draw-wire displacement sensors

More Precision. wiresensor // Draw-wire displacement sensors More Precision wiresensor // Draw-wire displacement sensors 22 Low-cost draw-wire displacement sensors wiresensor MK88 analog - Robust plastic housing - Customized versions for OEM - Potentiometer, current

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

Float switch For industrial applications Model RLS-1000

Float switch For industrial applications Model RLS-1000 Level measurement Float switch For industrial applications Model RLS-000 WIKA data sheet LM 50.0 Applications Level measurement of liquids in machine building Control and monitoring tasks for hydraulic

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

Electrical adapters, Sub-D socket, 9-pin Technical data

Electrical adapters, Sub-D socket, 9-pin Technical data Electrical adapters, Sub-D socket, 9-pin Fieldbus adapter FBA Fieldbus adapter Sub-D, 9-pin on M12 or screw terminal, for CANopen and DeviceNet General technical data Electrical connection 1 Straight socket,

More information

HARTING. Interface Connectors. People Power Partnership

HARTING. Interface Connectors. People Power Partnership 11 5 HARTING Interface Connectors People Power Partnership Directory chapter 00 Modular metric high speed connectors, 2.0 mm pitch Page connector system general information......................... 00.04

More information

Control hardware. IndraControl L75

Control hardware. IndraControl L75 2 Bosch Rexroth AG Electric Drives and Controls Documentation Advantages: Scalable hardware platform Standardized communication interfaces Optional extension through function and technology modules Ideal

More information

Digital I/O modules. 8 inputs/outputs, M8

Digital I/O modules. 8 inputs/outputs, M8 2 Bosch Rexroth AG Electric Drives and Controls Documentation Digital I/O module 8 inputs/outputs 0.5 A per channel M8 Technical data S67-DIO8-M8 Local bus interface Designation System bus M12 connector,

More information