Comms Task Programming

Size: px
Start display at page:

Download "Comms Task Programming"

Transcription

1 MODEL 3000 / ACCESS 4000 Programmer s Manual - Comms Tasks. Rev 5.10 [MENU 7-3-1] p 1 Comms Task Programming Introduction All system communication is controlled by means of Comms Tasks. As the name suggests a Comms Task is a communications task or job that you wish the system to carry out. Because there can be more than one Comms Task, it is also possible for more than one communications task to be operating at once. For example, to configure the system for a review printer you simply allocate one of the available Comms Tasks to perform the review printer function. If you wish an alarms dialer to be operational as well, you simply assign another Comms Tasks the job of being a dialer format such as Contact ID. The number of Comms Tasks available is dependent upon the Memory Configuration. Comms Tasks can either be active or idle. When the system is powered up, all programmed Comms Tasks are set to active so they can immediately start their intended function. If you wish to stop a Comms Task, for example abort a dialer format halfway through reporting, simply set that Comms Tasks to idle. IMPORTANT NOTE: This document covers basic Comms Task format selection and Active/Idle settings. For details of individual Comms Task format programming refer to the Comms Tasks Formats section. Communications Ports Comms Tasks use communications ports to communicate with the outside world. Listed below are the possible communications ports: 3. Comms Port Name Location Description Telecom Control Module PCB Connected to the telephone network or a direct line network and used for upload-download, dialer reporting formats, direct line formats etc. PORT 0 Control Module PCB Only used during installation. Can be used for direct connect upload/download with an adaptor only during installation. UART 1 UART Expander A general purpose RS232 port used for review printers, external PC connections, access control monitoring, special formats such as Securitel, fast modems to dial-up lines. Baud rate programmable. UART 2 UART Expander Same as UART 1 UART 3 UART Expander Same as UART 1 UART 4 UART Expander Same as UART 1 Ethernet Ethernet UART Expander (V5.1 or later) Connected to an Ethernet network and used for communications with Insight software or an IPfast Central Station Receiver. NOTE: The number of UART Ports available will depend upon the version of UART Expander fitted. When a Comms Task is set to carry out a function, for example send data to a review printer, it will be configured to use one of the communications ports listed above. For example a Comms Tasks programmed for a review printer may be configured to use UART Port 3. This means that UART Port 3 cannot be used for any other purpose unless the Comms Task is set to idle. Some Comms Tasks may share ports with other Comms Tasks. For example, a Comms Task programmed as a Contact ID dialer and another programmed as an IRfast format dialer. Although both these tasks are configured to use the Telecom port, when they are not reporting they are not using the port. If both tasks needed to use the Telecom port for reporting at the same time, one Comms Task will use the port first and, when finished, the other Comms Task will use the port.

2 [MENU 7-3-1] p 2 MODEL 3000 / ACCESS 4000 Programmer s Manual - Comms Tasks. Rev 5.10 Comms Task Formats. Comms Task formats describe the job a particular Comms Task is to perform. For example, programming Comms Task CT003 to Contact ID format will invoke a Contact ID dialer using CT003. The programming of options for the Contact ID dialer using CT003 are unique to Comms Task CT003. If another Comms Task, CT005, were also to be programmed to Contact ID format, the Contact ID options for this Comms Task will be separate from those of CT003. This allows the commissioning of dual reporting with each Comms Task using its own Telephone Numbers and options. Listed below and opposite are the possible formats that may be assigned to a Comms Task. Programming of individual formats are explained in more detail in Comms Task Formats in the following sections. Comms Format Section Number Monitor Comms- 1 Answer Call Comms- 2 PC Direct Comms- 3 IRfast Dialer Comms- 4 Contact ID Dialer Comms- 5 EMS Comms- 6 EarthNet Direct Line Comms- 7 (V1 to V4.5 only) Securitel Comms- 8 Printer Comms- 9 External Modem Comms-10 Inet Comms-11 Accept Comms-12 Poll Data Comms-13 PACOM Comms-14 (V3 to V4.5 only) IRfast Backup Dialer Comms-15 See Note 1 CID Backup Dialer Comms-16 See Note 1 GSM Comms-17 See Note 1 SpreadNet Wireless Interface Comms Pulse Dialer Comms-19 Geoquip Comms-21 See Note 2. Under development 8 pin Comms-22 See Note 2 C-Bus Comms-23 See Note 2 Inovonics Wireless Interface Comms-24 See Note 2 PosData DVR Comms-25 See Note 2 Dynalite Comms-26 See Note 2 HPM Comms-27 See Note 2. Under development Insight Comms-28 See Note 2 Insight Internal Modem Comms-29 See Note 2 Insight External Modem Comms-30 See Note 2 SIA Dialer Comms-31 See Note 2 IMPORTANT NOTES: 1) Any Comms Task used as a Backup Task operates as an independent Comms Task and must therefore have all the normal options programmed. i.e. Programming options are not automatically taken from the main Comms Task. 2) Available in Type 2 (CE) Control Modules or later only.

3 MODEL 3000 / ACCESS 4000 Programmer s Manual - Comms Tasks. Rev 5.10 [MENU 7-3-1] p 3 Comms Task Baud Rates IMPORTANT INFORMATION Maximum Baud Rate settings. Whenever more than one Comms Task is programmed it is important to ensure that the combined Baud rate of all Comms Tasks to be active at the same time does not exceed: Type 0 / Type 1 Control Modules: 19,200 Baud. Type 2 Control Modules: 38,400 Baud. eg. On a Type 1 Controller, if a SpreadNet Comms Task, which must communicate at 9600, and a Printer Comms Task, set to 1200, are used concurrently; a PC Direct Comms Task for PC System Management would have to be set to 4800 Baud to ensure that the total Baud rate does not exceed 19,200. In this example, the total Baud rate would be 15,600. When assigning Baud rates, do not forget to include the Baud rate of any Comms Task using the Telecom Port at the same time. (For Contact ID and IRfast formats allow 300 Baud; for Upload/Download formats allow 1200 Baud) Upload / Download. 3. Comms In addition to the general guidelines above, the following should be noted when connecting to a Type 0 or Type 1 Control Module for Upload/Download (PCDirect or ACCEPT Comms Tasks). For Upload/Download applications it is recommended that the Baud rate is set to the default value of 9600 Baud or lower. Baud rates of or above are not recommended and depending on the hardware and cabling used, may result in unreliable communications. UART Port Diagnostics CT001 Status.R.. nnnn Pressing the ON Key whilst the Active/Idle screen is displayed will display the UART Port status screen. This screen can be cleared (reset) when desired by pressing the OFF Key. The following table explains the flags:. Spare Spare for future development. R Retry A Y under this flag means the receive fifo (16 bytes) has overflowed and at least one character has been lost. This will normally cause a retry of some kind.. Spare. Spare Spare for future development. Spare for future development. The R flag may be monitored after communications via this port. In the event that the system places a Y flag under the R, the Status screen should be reset and monitored further. Should a Y flag appear under the R with some regularity, a potential cause would be the baud rate at which the port is attempting to communicate. In such a case the Installer should reduce the baud rate and monitor the effect via the status screen. In the event that lower baud rates do not solve the problem, assistance should be sought from the manufacturer s Service Technician.

4 [MENU 7-3-1] p 4 MODEL 3000 / ACCESS 4000 Programmer s Manual - Comms Tasks. Rev 5.10 Format Ports Used Descriptio n Monitor U ART 0 to 4 For manufacturer's use only. Answer Call Shares Teleco m Answers calls for upload/download, DTMF (Touch-tone) Telephone Remote Control and performs telephone line monitoring. Can be programmed to Callback the computer that initiated the call, for added security. PC Direct Used to allow a PC to be connected permanently to the 3000/4000 system for upload - download or access monitoring. IR Fast Contact ID S hares Teleco m Reports alarm information in Inner Range fast Format (Extended ) S hares Teleco m Reports alarm information in Ademco Contact ID format. EMS U ART 1 to 4 Used to communicate directly with high level lift control equipment. V3 or later. EarthNet Teleco m Reports alarm information in EarthNet Direct Line format via a direct line. Setting an EarthNet Comms Task to "active" will prevent any other Comms Task from sharing the Telecom Port. Securitel U ART 1 to 4 Reports alarm information via a Securitel STU connected to a UART port. Printer U ART 1 to 4 Used to continuously dump review information to a serial printer. External Modem Inet Used to periodically dump external modem. review to a remote PC via a separate line connected to an Allows multiple panels to communicate alarm data and a limited amount of database editin g commands to and from an automation package via an RS232 based network. Contact the Distributor for details. V3.5 or later. Accept Used to permanently connect a PC running ACCEPT System Management Software. V2 or later. Poll Data Allows the 3000/4000 system to be monitored and controlled by an external intelligen t system using Contact ID data format &/or system text. V3 or later. e.g. Guardall NZ Tripad or Santana CCTV Interface. PACOM Allows the 3000/4000 sytem to be monitored and controlled via a PACOM Network. V3 or later. IRfast Backup CID Backup Shares Teleco m GSM SpreadNet 4+2 pulse Shares Teleco m Buffer Reports alarm information in Inner Range format (Extended) when primary Comms forma t fails. S hares Teleco m Reports alarm information in Ademco Contact ID format when primary Comms format fails. Allows secure communications via GSM modem to central stations phones for alarm reporting and remote control. V3.5 or later &/or GSM mobil e Allows the 3000/4000 system to connect directly to a C&K Spreadnet receiver. later. Allows the 3000/4000 format. V3 or later. G eoquip Under development. 8 pin Auxiliary Output s V2 or system to connect directly to Central Stations using the 4+2 Puls e Special purpose Comms Task generated automatically when the GSM Comms Task is used. Allows the 3000/4000 system to activate Auxiliary outputs for 8 different types of alarms with Alarm confirmation (verification) logic for "Intruder" alarms. The Auxiliaries can then be used to trigger inputs on: - 3rd party communicators that support at least 8 pin inputs for reporting. e.g. Redcare STU, 8-pin STU, GSM STU, etc /4000 Zone Inputs for reporting via any other Comms Task such as Contact ID or IRfast. (Not available on Type 0 or 1 Control Modules)

5 MODEL 3000 / ACCESS 4000 Programmer s Manual - Comms Tasks. Rev 5.10 [MENU 7-3-1] p 5 Format Ports Used Descriptio n C-Bus U ART 1 to 4 Allows the 3000/4000 system to communicate directly with a Clipsal C-Bus Controller. V4 or later. (Not available on Type 0 or 1 Control Modules) Inovonics Allows the 3000/4000 system to connect directly to a C&K Spreadnet Receiver. V4 or later. (Not available on Type 0 or 1 Control Modules) PosData DVR Allows a PosData Model BX 4 Channel DVR to be controlled from a 3000/4000 LCD Terminal. (Not available on Type 0 or 1 Control Modules) Dynalite U ART 1 to 4 Allows the 3000/4000 system to communicate directly with a Dynalite Controller. V4.5 or later. (Not available on Type 0 or 1 Control Modules) H PM Under development. Insight Ethernet UART Shares Telecom (via "Insight Internal Modem") Insight Internal Modem Insight External Modem SIA Dialer Used to provide one or more communications paths to Insight Software (V5 or later) and/or an IPfast Central Station Receiver. (Under development) S hares Telecom Used to provide a dialer communications path to Insight Software (V5 or later ) UART 1 to 4 Used to provide a dialer communications path to Insight Softwarr connected to an external modem. (Under development) S hares Teleco m Reports alarm information in SIA format. (V5 or later ) via a separate lin e 3. Comms

6 [MENU 7-3-1] p 6 MODEL 3000 / ACCESS 4000 Programmer s Manual - Comms Tasks. Rev 5.10 Comms task to program: CT001 This screen allows the programmer to select a Comms Task to programme by using the up and down arrows or by entering a number. CT001 Idle -> Insight The screen has three roles: 1. It allows a Comms Task format to be selected by using the Right Arrow key to cycle through all the available formats. Pressing the OFF key selects None (No format) for this Comms Task and goes to the start of the list of available formats. 2. The 9 key is used to toggle the Comms Task between the Idle state and the Active state. A Comms Task format cannot be changed or programming changes made unless the Comms Task is idle. 3. Pressing HELP, 9 will allow options to be programmed for the particular format chosen for that Comms Task. It is recommended that options are only changed when the Comms Task is idle. Example: Contact ID has been selected for Comms Task CT001 CT002 Idle -> Contact ID CT002 Active -> Contact ID Although a format has been chosen, because the Comms Task is idle, no dialling or reporting will take place. To programme options for the Contact ID dialer using Comms Task CT001 press HELP, 9. To start Comms Task CT001, simply press the 9 key. The display will change to that of the screen on the left. The Contact ID dialer is now operational using CT001. To stop the Contact ID at any time, simply go to the above screen and press the 9 key to toggle the Comms Task back to idle. Defaults In V3 to V4.9x, Comms Task 1 (CT001) is defaulted to PC Direct format on Port 1 at 9600 Baud. In V5 or later, Comms Task 1 (CT001) is defaulted to Insight format on Port 1 at 9600 Baud. Comms Task 1 should not be used for any other format. Programming options and screens will vary depending on the format of Comms Task selected. For details of individual Comms Task format programming refer to the Comms Tasks Formats section.

Inet Comms Task Format

Inet Comms Task Format 11. Inet Comms-11-1 Inet Comms Task Format Purpose. The purpose of the Inet Comms Task is to allow multiple panels to communicate alarm data and a limited amount of database editing commands to and from

More information

Insight Comms Task Format. CT001 Idle -> Insight. CT001 Panel ID: CT001 Port -> to use: 1. CT001 Baud -> Rate: 9600

Insight Comms Task Format. CT001 Idle -> Insight. CT001 Panel ID: CT001 Port -> to use: 1. CT001 Baud -> Rate: 9600 MODEL 3000 / ACCESS 4000 Programmer s Manual - Rev 5.10 Insight Comms-28-1 Insight Comms Task Format This communication format allows the 3000/4000 system to connect to the Insight Upload / Download software.

More information

SIA Dialer Comms Task Format

SIA Dialer Comms Task Format MODEL 3000 / ACCESS 4000 Programmer s Manual - Rev 5.00 SIA Dialer Comms-31-1 SIA Dialer Comms Task Format Dialer Operation - SIA Dialer Format, Level 1. (V5 or later only) SIA Dialer format is used to

More information

T02. Review Messages

T02. Review Messages MODEL 3000 / ACCESS 4000 Programmer s Manual - Rev 5.20 T02. Review s Table - 1 T02. Review s CONTENTS Air-conditioning....2 Area On/Off....2 Auxiliary Events....2 Comms Task messages. General....3 Comms

More information

IRfast Comms Task Format

IRfast Comms Task Format IRfast Comms-4-1 IRfast Comms Task Format Dialer Operation - IRfast The Model 3000 and Access 4000 panels can communicate in IRfast dialer format to a suitably equipped Central Station. IRfast can be used

More information

Model 3000 & Access 4000

Model 3000 & Access 4000 Programming Manual. Memory Configurations. Rev 5. Page 1 Model 3000 & Memory Configurations V5.1 Contents Memory Size.... 2 Memory Configuration... 2 Determining the Memory Size and Configuration.... 2

More information

4+2 Pulse Comms Task Format. CT001 Client Code: CT001 PABX No.-> None. CT001 PABX No.-> TN000. CT001 1st No.-> None. CT001 2nd No.

4+2 Pulse Comms Task Format. CT001 Client Code: CT001 PABX No.-> None. CT001 PABX No.-> TN000. CT001 1st No.-> None. CT001 2nd No. MODEL 3000 / ACCESS 4000 Programmer s Manual - Rev 3.00 4+2 Pulse Comms-19-1 4+2 Pulse Comms Task Format The 4+2 Pulse format transmits 4 client code and 2 alarm digits to a Central Station using bursts

More information

Still provides for large security installations, but expands the access control capabilities.

Still provides for large security installations, but expands the access control capabilities. MODEL 3000 / ACCESS 4000 Programmer s Manual - Mem. Default. Rev 5.0 [MENU 7-5-2] p 1 Memory Defaulting Memory Configuration Options There are a range of Memory Configurations available in the Model 3000/4000.

More information

MULTIPATH IP USER MANUAL INNER RANGE. For Version 5.0 Software

MULTIPATH IP USER MANUAL INNER RANGE. For Version 5.0 Software MULTIPATH IP USER MANUAL INNER RANGE For Version 5.0 Software Disclaimer: Inner Range / Fratech MultipathIP Client User Manual: Revision 5.0 For MultipathIP Client software version 5.0 May, 2014 Copyright

More information

Telephone and Reporting Setup in ElkRP

Telephone and Reporting Setup in ElkRP Telephone and Reporting Setup in ElkRP 1. To add a telephone, right click on Telephones under Folder items on the left side of the screen. Then select New Telephone. 2. On the New Telephone IDs screen,

More information

LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER)

LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER) Applications Programming Guide - LIFT CONTROL WITH BUTTON FEEDBACK. Rev 4.51 Page 1 LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER) Lift control logic can be used to control Floor security for a

More information

Galaxy ACCeSS Lite Downloader

Galaxy ACCeSS Lite Downloader Galaxy ACCeSS Lite Downloader Installation and Operating Instructions Honeywell Security Table of contents Introduction...3 Note for Galaxy 3 series panels V5.0x...3 Installation...4 Set-up...4 Running

More information

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 1. Installation Requirements 1.1. PC Pentium III processor or higher. Minimum RAM memory: 128 Mbytes Operating system: Windows XP

More information

GETTING STARTED MANUAL

GETTING STARTED MANUAL Management Software for Concept 4000 Security / Access Systems GETTING STARTED MANUAL For Version 5 Software IMPORTANT NOTE: The version of Insight software available for download from the Website may

More information

The Icon Series. Icon 16, Icon 32, Icon 48. Installation and Programming Information. MCM Electronics MCM Electronics MCM Electronics

The Icon Series. Icon 16, Icon 32, Icon 48. Installation and Programming Information. MCM Electronics MCM Electronics MCM Electronics MCM Electronics MCM Electronics MCM Electronics The Icon Series Icon 16, Icon 32, Icon 48 Installation and Programming Information Version 4.5 and 5.0 Icon1648-010999.pm6 Index 1. Inputs. 2. Outputs.

More information

VISTA-128BP/VISTA-250BP Programming Form

VISTA-128BP/VISTA-250BP Programming Form VISTA-128BP/VISTA-250BP Programming Form Some fields are programmed for each partition (shown as shaded fields). If you are programming a multiple-partition system, see the Partition-Specific Fields section

More information

* * ARM MONITOR EXCLUDE MEMORY. HomeSafe Security Panel 5400/16CB. Programming Manual C-Bus Supplement

* * ARM MONITOR EXCLUDE MEMORY. HomeSafe Security Panel 5400/16CB. Programming Manual C-Bus Supplement * * ARM 1 2 3 MONITOR 4 5 6 EXCLUDE 7 8 9 MEMORY P 0 E HomeSafe Security Panel 5400/16CB Programming Manual C-Bus Supplement Contents 1.0 Product Range...3 2.0 Features...3 2.1 Control Panel Features...3

More information

USER MANUAL. Management Software for Concept 4000 Security / Access Systems. For Version 5 Software

USER MANUAL. Management Software for Concept 4000 Security / Access Systems. For Version 5 Software Management Software for Concept 4000 Security / Access Systems USER MANUAL For Version 5 Software IMPORTANT NOTE: The version of Insight software available for download from the Website may be newer than

More information

Section 1 Introduction

Section 1 Introduction Section 1 Introduction The Model 4824 Serial/Parallel Module provides one RS232 serial port and one parallel printer port. Eight 4824s could be used per system. You can use the 4824 for a variety of purposes,

More information

Insight User Manual: Fifth Edition For Insight software version September 19, Copyright Inner Range Pty. Ltd.

Insight User Manual: Fifth Edition For Insight software version September 19, Copyright Inner Range Pty. Ltd. Insight User Manual: Fifth Edition For Insight software version 3.2.1.2 September 19, 2007 Copyright 2006-2007 Inner Range Pty. Ltd. Text and Layout Tim Morris Additional Text Jason Snell Proofing Andy

More information

IRIS Touch Firmware Enhancements and Additions From Version to Version 1.11

IRIS Touch Firmware Enhancements and Additions From Version to Version 1.11 Overview IRIS Touch Firmware Enhancements and Additions From Version 1.9.5 to Version 1.11 This document details enhancements to the feature set of the IRIS Touch from firmware Version 1.9.5 to Version

More information

CONCEPT 3000/Access 4000 User Manual UK Supplement

CONCEPT 3000/Access 4000 User Manual UK Supplement CONCEPT 3OOO & Access 4000. 1 CONCEPT 3000/Access 4000 User Manual UK Supplement Revision 5.70 This manual is intended for use in conjunction with the Concept 4000 User Manual, Revision 5.6 or later. CONTENTS

More information

CT-Interface & IRIS Touch 600 Range Installation Manual

CT-Interface & IRIS Touch 600 Range Installation Manual CT-Interface & IRIS Touch 600 Range Installation Manual Coopers I-ON Panel Range Version 2.0 Table of Contents 1 System Overview... 3 2 IRIS Touch 640 PCB Layout... 3 3 Connections for Coopers I-ON Panel

More information

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0 MCM Electronics MCM Electronics MCM Electronics The Icon Series Installation and Programming Information Icon 8 Version 5.0 TABLE OF CONTENTS 1. 2. 3. Panel Hardware Page 2 Physical Layout. Inputs. Outputs.

More information

DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06

DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06 DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06 Requires Firmware Version: VL/2.17+ Revision History: Version 1.00 02 February 2004 Preliminary release version Version 4.01 21

More information

NDM Configurator. Introduction Page *3. Configuration Files 5. Downloading 17 APPLICATION NOTE

NDM Configurator. Introduction Page *3. Configuration Files 5. Downloading 17 APPLICATION NOTE System 9100 Technical Manual 636.4 Network Communications Section Application Note Issue Date 0896 APPLICATION NOTE NDM Configurator Introduction Page *3 Configuration Files 5 Hardware Requirements *5

More information

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; 1 for UL. 4140XMPT2 PROGRAMMING FORM Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these fields. Standard default (*97) values are shown

More information

FSA-CU Configuration Utility Programming Guide

FSA-CU Configuration Utility Programming Guide FSA-CU Configuration Utility Programming Guide Revision 3 October 2013 Introduction The following guide will show you the basics of the FSA-CU configuration utility program. The CU can be used with the

More information

APPLICATION NOTE. N2 Dial Application. Using N2 Dial...3. Introduction...3. Key Concepts...4

APPLICATION NOTE. N2 Dial Application. Using N2 Dial...3. Introduction...3. Key Concepts...4 FANs 637.5, 1637.5 N2 Dial Section Issue Date 0400 APPLICATION NOTE N2 Dial Application Using N2 Dial...3 Introduction...3 Key Concepts...4 N2 Dial Configuration... 4 Downloading with N2 Dial...*6 Dial-in

More information

SFC-500 Intelligent Addressable Fire Alarm Control Panel Configurator Software

SFC-500 Intelligent Addressable Fire Alarm Control Panel Configurator Software SFC-500 Intelligent Addressable Fire Alarm Control Panel Configurator Software SFC-500 Series Intelligent Addressable Fire Alarm Control Panel Configurator Software SFC-500 Series Programming The SFC-500

More information

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010 16-Input Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

Autodialer ADC Series

Autodialer ADC Series Advanced Life Safety Solutions Autodialer ADC Series Telephone Access System 3 4 5 7 8 9 0 User s Guide LT-883 Rev. 0 April 2005 Autodialer ADC Series Telephone Access System User Guide Contents Introduction...

More information

4 balanced inputs 1 relay output

4 balanced inputs 1 relay output Cardax FT Controller 5000GL provides flexible system architecture with options of GBUS and LOCAL BUS communications to field devices, to meet a wide range of site requirements. Cardax FT Controller 5000GL

More information

Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above.

Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above. Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above. Please note that this manual has been prepared to highlight the new PD6662, BS8243 and EN50131-1 features. RINS1530-1 CHAPTER

More information

GETTING STARTED. Installing the System 2000 Hardware. Configuring Your System 2000 Hardware. Troubleshooting. Configuring Your System 2000 Network

GETTING STARTED. Installing the System 2000 Hardware. Configuring Your System 2000 Hardware. Troubleshooting. Configuring Your System 2000 Network SYSTEM 2000 GETTING STARTED Installing the System 2000 Hardware Whether you are upgrade an existing System 2, or this is a brand new installation, there will be some hardware installation involved. We

More information

AV-4000 GSM AV-4000 DVR

AV-4000 GSM AV-4000 DVR E a s y L o a d e r AV-4000 GSM AV-4000 DVR (for LED keypads) Integrated Alarm Control panel & Communicator Series 4000 Appendix for GSM Alarm Panels Version 1.05 Edition I This product is subject to continuous

More information

eurösec CPX Control Panel User Instructions

eurösec CPX Control Panel User Instructions eurösec CPX Control Panel User Instructions eurösec CPX User Manual Contents User Information... 2 Introduction... 3 User Code Types... 3 Setting The System... 4 Setting & Unsetting via Keyswitch... 4

More information

4140XMPT2 PROGRAMMING FORM

4140XMPT2 PROGRAMMING FORM 414XMPT2 PROGRAMMING FORM Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these fields. Standard default (*97) values are shown

More information

2 IDS LCD Keypad User Manual C Issued March 2009

2 IDS LCD Keypad User Manual C Issued March 2009 2 3 4 Contents 1. Introduction to the IDS LCD Digital Keypad...8 2. Arming the Control Panel...8 2.1 Away Arming...8 2.1.1 How to Away Arm...8 2.1.2 Quick Away Arm Shortcut Key...8 2.2 Stay Arming...9

More information

ETC II Modbus Communications Protocol Reference Guide

ETC II Modbus Communications Protocol Reference Guide ETC II Modbus Communications Protocol Reference Guide SATEC Ltd. BG0595 Rev. A1 Every effort has been made to ensure that the material herein is complete and accurate. However, the manufacturer is not

More information

Metasys Integrator Northern Application

Metasys Integrator Northern Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0900 APPLICATION NOTE Metasys Integrator Northern Application lntroduction Page *3 Application Details

More information

Ademco Group Compass Network Downloader

Ademco Group Compass Network Downloader Ademco Group Compass Network Downloader Table of Contents Section 1. Introduction Chapter 1: Chapter 2: Chapter 3: Welcome...1-1 Key Features...1-1 System Requirements...1-2 Using This Manual...1-2 Windows

More information

IDEA. User s Guide. Part No IDE02 Issue 1-0, April 1995 Printed in U.S.A. (183)

IDEA. User s Guide. Part No IDE02 Issue 1-0, April 1995 Printed in U.S.A. (183) IDEA User s Guide Part No. 17500IDE02 Issue 1-0, April 1995 Printed in U.S.A. (183) 4 FOREST PARKWAY, SHELTON, CONNECTICUT 06484 TEL: 203-926-5400 FAX: 203-929-0535 This manual has been developed by Nitsuko

More information

ADVANCED USER S GUIDE

ADVANCED USER S GUIDE ADVANCED USER S GUIDE MFC-7360 MFC-7360N MFC-7460DN MFC-7470D MFC-7860DW Not all models are available in all countries. Version A SAF/GLF User's Guides and where do I find it? Which manual? What's in it?

More information

Control Panel DS7400XiV4-EXP

Control Panel DS7400XiV4-EXP Control Panel DS7400XiV4-EXP Release Notes January 2005 Release Notes for Firmware Version 4.10 Trademarks Cobox is a trademark of Lantronix. 1.0 Remote Programming Compatibility Use RPS-INT L version

More information

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer Slide 1 XT30/XT50 Basic Training Programming- Part 1 Slide 2 Objectives After completing this course you will: 1) Understand how to prepare the panel for programming and how to access the built-in programmer.

More information

Advanced User s Guide

Advanced User s Guide Advanced User s Guide MFC-9140CDN MFC-9330CDW MFC-9340CDW Not all models are available in all countries. Version 0 ARL/ASA/NZ User s Guides and where do I find them? Which Guide? What s in it? Where is

More information

XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors

XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors Name Answer Key Company Address City, State, Zip Instructor Date Your email User Name = Password = XR500/XR100 Command Processor Review 1. may be connected to the LX-Bus. a) Zone expanders c) Output expanders

More information

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series INSTALLATION & OPERATING GUIDE Rev. B P/N 3321515 www.securakeystore.com (800) 878-7829 sales@securakeystore.com COPYRIGHT 2001

More information

660/960 Installation Guide

660/960 Installation Guide 660/960 Installation Guide Compatible Equipment 660: Any Scantronic control panel. 960: All control panels with the Scantronic plug-on footprint pins. 496354 Issue 1 1 of 16 660/960 Introduction The 660/960

More information

Extension module for BACnet over Ethernet / IP and graphic Web functions

Extension module for BACnet over Ethernet / IP and graphic Web functions s 9 265 9263p01 DESIGO PX Extension module for BACnet over Ethernet / IP and graphic Web functions Plugs into the modular automation stations, type PXC...-U PXA30-W2 For operation of the PXC -U automation

More information

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide Control Panel ICP-SOL2-P/ICP-SOL3-P en Quick Reference Guide Control Panel Table of Contents en 3 Table of contents 1 Introduction 6 2 Programming 7 2.1 ICON LCD Codepad Programming 7 2.2 TEXT LCD Codepad

More information

EC-11 Ethernet Converter

EC-11 Ethernet Converter EC-11 Ethernet Converter PSTN Contact ID to TCP Converter Installation and Operations Manual Version 8.H3.MID 1 Table of Contents About EC-11 Ethernet Converter... 3 Circuit Board Layout and Wiring Diagram...

More information

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security System with Scheduling Programming Guide K0376PRV5 2/11 Rev. A Table of Contents Programming Field Settings for UL864 Compliance

More information

VISTA-50P VISTA-50PUL

VISTA-50P VISTA-50PUL VISTA-50P VISTA-50PUL PARTITIONED SECURITY SYSTEM with SCHEDULING Quick Start Step-by-Step Programming Procedure Single And Multiple Partition Programming Forms System Worksheets VISTA50P-PR 8/95 (See

More information

TiSecurityPolyx user manual

TiSecurityPolyx user manual Version 1.0 06/08 - CT TiSecurityPolyx user manual Software for the configuration of the 3485 Burglar Alarm Unit CONTENTS 1. Hardware and Software requirements 4 2. Installation 4 3. Basic concepts 8

More information

You have accessed an older version of a Paradyne product document.

You have accessed an older version of a Paradyne product document. You have accessed an older version of a Paradyne product document. Paradyne is no longer a subsidiary of AT&T. Any reference to AT&T Paradyne is amended to read Paradyne Corporation. Paradyne 6700-A2-GB41-10

More information

Darca Plus Eltek Download ing And Remote Con trol Applica tion

Darca Plus Eltek Download ing And Remote Con trol Applica tion Eltek Downloading And Remote Control Application Copyright Microsoft, Windows 98-SE/ME, Windows NT, Windows 2000/XP, Vista, Windows 7 and Excel are registered trademarks of Microsoft Corporation. This

More information

Triton ATM Configuration

Triton ATM Configuration Triton ATM Configuration Perform each of the following steps for proper ATM set-up. Items 1 through 11 are required to properly set up an ATM for use. The remaining items are optional. The list of optional

More information

Intelligent Monitoring. Taking intelligent monitoring to a higher level

Intelligent Monitoring. Taking intelligent monitoring to a higher level Intelligent Monitoring Taking intelligent monitoring to a higher level SEB NET-PATH : More powerful capabilities than ever before Today s large private enterprise networks and service organizations rely

More information

CONVENIENT INSTALLATION For installation convenience, the SG-SLR is packaged in a desktop Card Cage.

CONVENIENT INSTALLATION For installation convenience, the SG-SLR is packaged in a desktop Card Cage. INTRODUCING THE The is a Single-Line, Multi-Format Digital Receiver designed to interpret a variety of communications formats for the ultimate in convenience and versatility. The will provide features

More information

Ethernet UART System Administrator Setup Guide

Ethernet UART System Administrator Setup Guide Page 1 of 16 Introduction The Ethernet UART board provides the Model 3000/4000 Type 2 Control Module (panel) with: -A 10BaseT Ethernet connection to allow System Management and/or Reporting via the IP

More information

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

Safecom Solution-16 Quick Reference Guide ISSUE 1.10 Safecom Solution-16 Quick Reference Guide ISSUE 1.10 2 Solution-16 Safecom Quick Reference Guide Safecom Solution-16 Quick Reference Guide Copyright 1998 by, SYDNEY, AUSTRALIA Document Part Number MA8016Q

More information

XN120 PC Pro Guide Getting Started Rev 1.2 (January 2007)

XN120 PC Pro Guide Getting Started Rev 1.2 (January 2007) This guide explains the PC programming tool, Pre config files, and common areas to customise from the Pre Config files for the XN120 Telephone System. The guide also explains the various methods of connecting

More information

Hello, and welcome to this presentation of the STM32 Low Power Universal Asynchronous Receiver/Transmitter interface. It covers the main features of

Hello, and welcome to this presentation of the STM32 Low Power Universal Asynchronous Receiver/Transmitter interface. It covers the main features of Hello, and welcome to this presentation of the STM32 Low Power Universal Asynchronous Receiver/Transmitter interface. It covers the main features of this interface, which is widely used for serial communications.

More information

Challenger Series Administrators Manual

Challenger Series Administrators Manual Challenger Series Administrators Manual P/N MAADMN-TS1016 REV 07 ISS 20AUG15 Copyright Trademarks and patents Manufacturer Agency compliance Contact information 2015 UTC Fire & Security Australia Pty Ltd.

More information

Doug Fleenor Design, Inc. RS-232 to DMX512 Interface, 2 Generation. March 8, 2010 (Software V1.2)

Doug Fleenor Design, Inc. RS-232 to DMX512 Interface, 2 Generation. March 8, 2010 (Software V1.2) Doug Fleenor Design, Inc. nd RS-232 to DMX512 Interface, 2 Generation March 8, 2010 (Software V1.2) The second generation RS-232 to DMX512 interface has numerous features beyond the original device. The

More information

Colour Graphic Terminal User Manual. Rev 3.1

Colour Graphic Terminal User Manual. Rev 3.1 Integriti. Colour Graphic Terminal User Manual. 1 Colour Graphic Terminal User Manual. Rev 3.1 2013-2014. Inner Range Pty. Ltd. Part Number: 636000U 2 Integriti. Revision 3.1 June 2014. SYSTEM DETAILS

More information

ALERT CONFIGURATION GUIDE SIA DRIVER

ALERT CONFIGURATION GUIDE SIA DRIVER ALERT CONFIGURATION GUIDE SIA DRIVER 1) Installation A) SIA modem installation The SIA modem must be connected to a serial port on the PC (COM1, ) and plugged in an analog phone line. The modem being completely

More information

FPD-7024 Fire Alarm Control Panel Version 1.03

FPD-7024 Fire Alarm Control Panel Version 1.03 FPD-7024 Fire Alarm Control Panel Version 1.03 Program Record Sheet Account Information: Account: Date: Name: Address: Panel Phone #: Contact Phone #: Contact Person: Comments: Panel Location: Notes: Program

More information

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Australian Owned, Designed and Manufactured Master Unit GEN-001 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

This page intentionally left blank

This page intentionally left blank This page intentionally left blank CONCEPT 2000 USER'S MANUAL TABLE OF CONTENTS Basic Concepts...3 AREA...3 USERS...3 ZONES...3 ON And OFF...4 TERMINAL...4 Description Of The Keys...5 Operating your System...7

More information

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup) INPUTS: All inputs: Inputs 1 to 24: Tamper: Panic: Fire: Keyswitch: 16-18VAC: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

More information

PMAC Supplemental Manuals

PMAC Supplemental Manuals PMAC Supplemental Manuals CONTENTS PMAC SMS User's Guide...2 SMS Alarm Manager User's Guide...21 PMAC Alarm Wizard Manual...26 PMAC-SMS USER S GUIDE (under development) Last Updated: 26 th March 2001 By

More information

Product Specification

Product Specification Security Management Software The access control & security management software is designed to provide a range of new benefits to users. Enabling connectivity to Challengers using the Ethernet is its primary

More information

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL 01/2004 Centaur is a registered trademark of Position Technology INC. Pro-Report, Tracker, FrontGuard and FrontView are trademarks of Position Technology Inc.

More information

Triton ATM Configuration

Triton ATM Configuration Triton ATM Configuration Perform each of the following steps for proper ATM set-up. Items 1 through 12 are required in order to properly set up an ATM for use. The remaining items are optional. The list

More information

IrDA lite protocol stack for Atmel AVR microcontrollers

IrDA lite protocol stack for Atmel AVR microcontrollers IrDA lite protocol stack for Atmel AVR microcontroller 1 / 5 IrDA lite protocol stack for Atmel AVR microcontrollers Features: IrDA lite protocol fully implemented in firmware (only IR-transceiver required)

More information

Integriti User Manual. Elite / EliteX LCD Terminal Keypads

Integriti User Manual. Elite / EliteX LCD Terminal Keypads Integriti User Manual Elite / EliteX LCD Terminal Keypads INNER RANGE recommends that all INTEGRITI systems are installed & maintained by FACTORY CERTIFIED TECHNICIANS. For a list of Accredited Dealers

More information

Control Panel Solution 2000 / 3000

Control Panel Solution 2000 / 3000 Control Panel Solution 2000 / 3000 en Quick Reference Guide Control Panel Table of contents en 3 Table of contents 1 Introduction 6 2 Programming 7 2.1 Alphanumeric Codepad Menu Programming 7 2.2 ICON

More information

Serial Interface Module

Serial Interface Module OnQ 363737-01 Serial Interface Module DESCRIPTION The 363737-01 Serial Interface can be used with Model 925 or Model 1050 controller. It allows the controller to be connected to a personal computer or

More information

Extension module for graphic Web functions for one automation station

Extension module for graphic Web functions for one automation station s 9 266 9263p01 DESIGO PX Extension module for graphic Web functions for one automation station Plugs into the modular automation stations, type PXC...-U For operation of the PXC -U automation stations

More information

USER MANUAL. BioPro SA50 Fingerprint & Palm Terminal. Version: 1.0 Date: August Inch TFT Terminal User Manual 1

USER MANUAL. BioPro SA50 Fingerprint & Palm Terminal. Version: 1.0 Date: August Inch TFT Terminal User Manual 1 USER MANUAL BioPro SA50 Fingerprint & Palm Terminal Version: 1.0 Date: August. 2017 2.4 Inch TFT Terminal User Manual 1 About This Manual This manual introduces the operation of user interfaces and menu

More information

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 FEATURE DEFINITIONS... 3 TERMINAL DRAWING AND SPECIAL

More information

LX8 emfone. Installation and Configuration. TVL No. 336 Issue No. 1 03/10/2011

LX8 emfone. Installation and Configuration. TVL No. 336 Issue No. 1 03/10/2011 LX8 emfone Installation and Configuration TVL No. 336 Issue No. 1 03/10/2011 Thames Valley Controls Unit 15 Manor Farm Industrial Estate Flint Flintshire CH6 5UY T: +44 (0) 1352 793222 F: +44 (0) 1352

More information

CUSTOMER INFORMATION

CUSTOMER INFORMATION CUSTOMER INFORMATION COMPANY NAME & ADDRESS: CONTACT: PHONE: FAX: NOTES: DATE ENTERED: DATE MODIFIED: 11/2/2010 12:41 P 11/2/2010 12:47 P USER_DEFINED_FIELD1: USER_DEFINED_FIELD2: Vista15PSIA-3 PROGRAMMING

More information

Concepts of Serial Communication

Concepts of Serial Communication Section 6. Serial Communication Communication Using Serial Interfaces: UART and SPI Concepts of Serial Communication Limitations of Parallel Bus Clock skew becomes a serious issue for high speed and long

More information

Identifier Caller ID and Line Monitor

Identifier Caller ID and Line Monitor Identifier Caller ID and Line Monitor This page contains the Identifier description, benefits, uses, technical specifications, and price. The Identifier comes in 2, 4, and 8 line models. These units daisy

More information

Interfacing to Multiple Vortex Devices via Multiple RS-232 Devices Simultaneously

Interfacing to Multiple Vortex Devices via Multiple RS-232 Devices Simultaneously Interfacing to Multiple Vortex Devices via Multiple RS-232 Devices Simultaneously Application Note Polycom Installed Voice Business Group September 2004 Rev. E 1 INTRODUCTION This application note illustrates

More information

Application Bulletin

Application Bulletin INTELLIGENT CONTROLS INC 34 SPRING HILL RD SACO ME 04072 U S A Application Bulletin 000-1351 Rev. D 1250-LTC ASCII Programming Interface Purpose: To instruct technicians in installing and using the 1250-LTC

More information

DAQ Electronics, Inc 262B Old New Brunswick Road, Piscataway, NJ

DAQ Electronics, Inc 262B Old New Brunswick Road, Piscataway, NJ DAQ Electronics, Inc 262B Old New Brunswick Road, Piscataway, NJ 08854-3756 DNP3 Server Configuration CallistoView version 5.0A This is a description of the unique DNP configuration dialogs and files in

More information

Station 2. Inverter. PU connector (Note1)

Station 2. Inverter. PU connector (Note1) using the E500 series drives General This data sheet describes the correct techniques for using E500 series inverters on a standard RS485 serial comms link. Up to 32 inverters may be connected. Max comms

More information

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads... HWZRU;;( Control/Communicator Installation Manual Table of Contents General Description... Ordering Information... Feature Definitions... Programming the LED Keypads... Programming the NX-E...9 Types of

More information

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual FERGUSON BEAUREGARD RTU-5000 Configurator User Manual FERGUSON BEAUREGARD RTU-5000 Configurator User Manual The Ferguson Beauregard RTU-5000 Configurator program and manuals are Copyright 1997-2004 by

More information

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3 THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Digi-modems Issue 3 Contents Com300 & Com2400 Installation Manual Contents 1. Regulatory Requirements... 3 General...3 Approval... 3 REN Rating... 3 2.

More information

VIP-102B IP Solutions Setup Tool Reference Manual

VIP-102B IP Solutions Setup Tool Reference Manual VIP-102B IP Solutions Setup Tool Reference Manual Version 6.3.0.0 For latest updates to this manual please check our website at: http://www.valcom.com/vipsetuptool/default.htm then click on Reference Manual

More information

Extension module for Web functions generic

Extension module for Web functions generic s 9 264 9263p01 DESIGO PX Extension module for Web functions generic Plugs into the modular automation stations, type PXC...-U PXA30-W1 Extension module for PXC -U automation stations in the DESIGO building

More information

rview Produc Ove imil s ac ure at Operating Instructions c F (For Advanced Operations) Facsimile Transceiver ure csimile at Fe Advanced

rview Produc Ove imil s ac ure at Operating Instructions c F (For Advanced Operations) Facsimile Transceiver ure csimile at Fe Advanced Problem Solving Setting Your Machine Network Scanner Feature Basic Facsimile Feature Advanced Facsimile Feature Appendix Advanced Internet Fax Feature Internet Fax/ Email Features Copy Feature Product

More information

INSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE

INSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE SenTech Corporation 5745 Progress Road Indianapolis, Indiana 46241 888/248-1988 FAX 317/248-2014 INSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE ii APPLICABILITY

More information

Technical Manual. for ZX-1004 Caller ID Simulator. For Processor Versions covering all International Caller ID Formats

Technical Manual. for ZX-1004 Caller ID Simulator. For Processor Versions covering all International Caller ID Formats Technical Manual for ZX-1004 Caller ID Simulator For Processor Versions covering all International Caller ID Formats Caller ID.com ZX-1004 Caller ID/Telephone Simulator (Version 1.0 10/20/2006) Description

More information