Communication Setup Tool for PF900/PF901 Program Controller (WinUCI-PF900)

Size: px
Start display at page:

Download "Communication Setup Tool for PF900/PF901 Program Controller (WinUCI-PF900)"

Transcription

1 Communication Setup Tool for PF900/PF901 Program Controller (WinUCI-PF900) INSTRUCTION MANUAL R RKC INSTRUMENT INC. MAY 2010 IMT01D09-E1 CAUTION This tool can monitor and set all the setup data of the program controller (PF900/PF901) including Engineering setting. Consequently, changes up to the specifications of the program controller are possible. Specification changes shall be made by the customer. Note that RKC will not be responsible when equipment and product loss accompanies specifications changes. NOTICE This manual assumes that the reader has a fundamental knowledge of the principles of electricity, process control, computer technology and communications. The figures, diagrams and numeric values used in this manual are only for purpose of illustration. RKC holds the ownership and copyright of this software and this document. RKC is not responsible for any damage or injury that is caused as a result of using this instrument, instrument failure or indirect damage. RKC is not responsible for any damage and/or injury resulting from the use of instruments made by imitating this instrument. The specifications of the software and the information in this document are subject to change without prior notice. If the specifications of the software do not correspond with the contents of this document, the software specifications have priority. RKC software is licensed for use with one computer and cannot be modified. This software may not be duplicated except for backup purposes. This manual explains how to use the software only. For operation procedures parameters of the controller, refer to the PF900/PF901 Instruction Manual (IMR02L03-E ) or PF900/PF901 User's Manual (IMR02L04-E ). SYMBOLS : This mark indicates important information on installation, handling and operating procedures. : This mark indicates supplemental information on installation, handling and operating procedures. : This mark indicates where additional information may be located. RKC INSTRUMENT INC.

2 CONTENTS 1. OUTLINE...3 Software operating environment... 3 Objective models... 3 Language support... 3 Functions... 3 Caution and restrictions CONNECTIONS Connections for Loader Communication... 4 Wiring method... 5 When using the front loader port... 5 When using the bottom loader port Wiring for Host Communication... 6 Communication terminal number and signal details INSTALLING WinUCI-PF Installing WinUCI-PF To uninstall the setting tool START THE SETTING TOOL...10 Start the setting tool Mode selection When Direct mode is selected Communication parameter setting Communication port check When File mode is selected PARTS DESCRIPTIONS AND MENU LIST Parts Descriptions Pattern Display Pattern display of Monitor and Operation screen Pattern display of Set pattern 1 and Set pattern 2 screen Menu List DATA MONITORING AND SETTING (EXAMPLE)...19 Monitor data in Direct mode Set parameter settings of PF900/PF901 in Direct mode from the PC SAVE PARAMETER SETTING DATA, AND USE BATCH SETTING (EXAMPLE) Save Parameter Settings of PF900/PF901 in the PC Send Parameter Settings of Set Value File (CSV format) to PF900/PF901 by Batch Setting Copy Parameter Settings of the PF900/PF901 to Other PF900/PF Compare Parameter Settings in a Set value File (CSV format) and Those in PF900/PF DISPLAYING TREND GRAPH (EXAMPLE) DISPLAY SOFTWARE VERSION INFORMATION EXIT THE SETTING TOOL IMT01D09-E1

3 1. OUTLINE Software operating environment The following hardware and software requirements have to be met for installing and operating the software: PC on which Windows XP, Windows Vista or Windows 7 runs comfortably without operational or response problem. OS: Windows XP SP2 or later, Windows Vista SP1 or later, Windows 7 Screen resolution: 1024 x 768 pixels (XGA) or higher is recommended Supported font sizes (DPI): Regular size (96 dpi) (Windows XP, Windows Vista, Windows 7) Free serial interface or USB 2.0 port Objective models PF900/PF901 Language support Japanese or English Functions Program controller setting data, including engineering settings, can be monitored and set. All settings in the program controller can be saved as a file on a computer, and all settings in a file can be set in the program controller. The set values saved in a file can be checked against the set values configured in the program controller. Graph of program pattern can be displayed. A trend graph can be displayed. Trend data can be saved in the PC as data record file (CSV format). Can be used in Loader communication and Host communication (only RKC communication). Caution and restrictions Errors may be displayed even if batch setting has been successfully done. Make sure the relevant set data will not affect the control action when such errors are shown. While setting parameters by Direct Mode of the setting tool (WinUCI-PF900), DO NOT change parameter settings of PF900/PF901 by front key operation or other communication to avoid data discrepancies between the setting tool and PF900/PF901. IMT01D09-E1 3

4 2. CONNECTIONS To prevent electric shock or instrument failure, turn off the power before connecting or disconnecting the instrument and peripheral equipment. 2.1 Connections for Loader Communication To connect PF900/PF901 with a PC, the following hardware and connection are necessary. PF900/PF901 is connected to COM-K (USB communication converter manufactured by RKC Instrument) by proprietary loader communication cable, and COM-K is connected to a PC by proprietary USB cable. Personal computer (USB port: Based on USB Ver. 2.0) RKC USB communication converter COM-K COM-K- Loader communication cable W-BV-03 loader communication cable (Standard cable length: 1.5 m supplied with COM-K-3) W-BV-01 loader communication cable (Standard cable length: 1.5 m supplied with COM-K-1) USB cable (Standard cable length: 1 m, COM-K- accessory) USB driver for COM-K * 3: With W-BV-03 loader communication cable (for connecting to the loader communication port in front.) 1: With W-BV-01 loader communication cable (for connecting to the loader communication port at the bottom.) * When using the loader communication, USB driver for COM-K must be installed on the personal computer. The USB driver for COM-K is in the CD-R which comes with PF900/PF901 as compressed file. It also can be downloaded from the official RKC website. COM-K usb_driver.exe Software (self-extracting file) 1 usb_driver.zip Software (ZIP file) 2 Instruction Manual English version IMR01Z01E.pdf COM-K Instruction Manual (PDF file) IMT01D07E.pdf Installation of USB driver for COM-K (PDF file) 1 Execute usb_drier.exe to extract compression files. 2 To use usb_driver.zip, prepare for an appropriate software to extract by a customer. In addition, the USB driver for COM-K can be downloaded from the official RKC website: URL: For the COM-K, refer to the COM-K Instruction Manual (IMR01Z01-E ). The Loader port is only for parameter setup. Loader communication can be used on a PF900/PF901 even when the communication function (option) is not installed. To use Front loader port, Loader communication cable must be W-BV-03. W-BV-03 comes with COM-K-03 from the factory. W-BV-03 is also sold separately for COM-K-N and COM-K-1. 4 IMT01D09-E1

5 Wiring method Connect the PF900/PF901, COM-K, and Personal computer using a USB cable and a Loader communication cable. Make sure the connectors are oriented correctly when connecting. Use only one of the loader ports (front or bottom) at the same time. Do not use both at the same time. Communication port of personal computer USB port: Based on USB Ver. 2.0 Communication settings on the personal computer (The following values are all fixed) Communication speed: bps Start bit: 1 Data bit: 8 Parity bit: Without Stop bit: 1 The device address for loader communication is fixed at 0. The setting of the device address is disregarded. Communication protocol RKC communication protocol (Based on ANSI X subcategories 2.5 and A4) When using the front loader port Use W-BV-03 to connect PF900/PF901 to COM-K. To communicate with PF900/PF901 by the front loader port, PF900/PF901 must be powered ON. Personal computer Connect to USB port USB cable 1 m (COM-K accessory) Connect to USB connector USB communication converter COM-K When using the bottom loader port Use W-BV-01 to connect PF900/PF901 to COM-K. Connect to loader communication connector of PF900/PF901 Connect to loader communication connector Loader communication cable 1.5 m (W-BV-03) [COM-K-3 accessory] PF900/PF901 Front panel view PV TM H:M:S SV 28 PTN SEG RESET RUN FIX MAN HOLD STEP R.SET PTN END MONI PF900 SET $ 40:00 200! 1 1 DO MODE Loader communication connector To communicate with PF900/PF901 by the bottom loader port, PF900/PF901 is not necessary to be powered ON. When monitoring the measured value (PV) or pattern, PF900/PF901 must be powered ON. Personal computer Connect to USB port Connect to USB connector Connect to loader communication connector of PF900/PF901 PF900/PF901 Bottom View USB cable 1 m (COM-K accessory) Connect to loader communication connector USB communication converter COM-K Loader communication cable 1.5 m (W-BV-01) [COM-K-1 accessory] Loader communication connector IMT01D09-E1 5

6 2.2 Wiring for Host Communication PF900/PF901 communicates with host computer by optional host communication function using terminals. The protocol is RKC (ANSI X subcategories 2.5 and A4) or Modbus*. Host communication function can be used when communication function is specified (code: 1, 4, 5, W, or X) when ordering. * This software (WinUCI-PF900) supports only RKC protocol. To check data send/receive status by Modbus communication protocol, use WMsci communication software. WMsci can be downloaded from the official RKC website. URL: For the protocol and specification of Host Communication, refer to PF900/PF901 Instruction Manual (IMR02L03-E ). The cable must be provided by the customer. Communication terminal number and signal details PF900/PF901 裏面 Communication terminal RS-232C Terminal No. Signal name Symbol 25 Signal ground SG (GND) 26 Send data SD (TXD) 27 Receive data RD (RXD) 28 Unused 29 Unused RS-485 Terminal No. Signal name Symbol 25 Signal ground SG 26 Send/Receive data T/R (A) 27 Send/Receive data T/R (B) 28 Unused 29 Unused RS-422A Terminal No. Signal name Symbol 25 Signal ground SG 26 Send data T (A) 27 Send data T (B) 28 Receive data R (A) 29 Receive data R (B) For typical connection between PF900/PF901 and host computer, refer to PF900/PF901 Instruction Manual (IMR02L03-E ). 6 IMT01D09-E1

7 3. INSTALLING WinUCI-PF900 Installing WinUCI-PF900 CAUTION Log in by user account with administrator status. Exit and close all applications on the PC. If an old version of WInUCI-PF900 is already installed in the PC, uninstall the old version before installing the new version. Screen examples in description are for Windows XP. If other OS is used, screen and name may vary. 1. Save SetupWinUciPF900E_xxxx.msi file in the hard disk of a PC. (xxxx represents a version number.) The file can be copied from the CD-ROM of PF900/PF901 in the PF900/PF901 package, or can be downloaded from the official RKC website. Copy from the PF900/PF901 CD-ROM a) Open WinUCI folder in the PF900/PF901 CD-ROM. b) Copy SetupWinUciPF900E_xxxx.msi in any folder of the hard disk of the PC. WinUCI folder contains the software and the instruction manual. WinUCI SetupWinUciPF900E_xxxx.msi Software Instruction Manual English version IMT01D09E.pdf Setup Tool WinUCI-PF900 Instruction Manual (this manual) Download from the official RKC website Download SetupWinUciPF900E_xxxx.msi from the official RKC website, and save any folder in the hard disk of the PC. URL: 2. Execute SetupWinUciPF900E_xxxx.msi, and Setup Wizard window is displayed. Click [Next] button. Execute When a warning window is displayed Windows XP SP2 or later: When a security alarm message, click [Execute] button. Windows Vista, Windows 7: When user account control window is displayed, click [Continue] or [OK] button. IMT01D09-E1 7

8 3. Select a folder to install the file, then click [Next] button. 4. Click [Next] to start the installation. 8 IMT01D09-E1

9 5. When installation is completed, WinUCI-PF900 Information (ReadmeE.txt) window is displayed. When you have finished reading the WinUCI-PF900 Information window, then click [Next] button. 6. Installation Complete window is displayed. Click [Close] to exit. To uninstall the setting tool To uninstall the setting tool (WinUCI-PF900), use program delete menu in Control Panel of Windows. IMT01D09-E1 9

10 4. START THE SETTING TOOL Start the setting tool 1. Click WinUciPF900 desktop icon, or go to Start menu and select WinUciPF900. The setting tool is opened, and the Mode select screen is displayed. Click a shortcut icon for WinUciPF900.exe. 2. Click the mode button to select Direct or File mode. Mode selection Click the mode button to select Direct or File mode. Direct mode: File mode: Communicate with the controller to monitor and change PF900/PF901 data. Connect PF900/PF901 with the PC, then click [Direct mode] button. Refer to the When Direct mode is selected (P. 11). Open a PF900/PF901 set value file (CSV format) saved in the PC to check parameter settings in the set value file, or copy parameter settings in the set value file to PF900/PF901 as batch setting (for data recovery or copy). Refer to the When File mode is selected (P. 13). 10 IMT01D09-E1

11 When Direct mode is selected 1. Communication parameter screen is displayed. Change the communication parameter settings to match the PF900/PF901, then click [OK] button. Communication parameter setting For loader communication, ckeck [use loader port]. When loader communication is used, communication speed and data bit configuration are fixed, and not necessary to be set. Comm port number: COM1 to COM256 Communication port check (P. 11) Device address: 0 to 99 (Maximum connections: Up to 31 controllers) Speed: 2400 bps 4800 bps 9600 bps bps bps bps Data bit length: 7-bit or 8-bit Parity: Non, Odd or Even Stop bit length: 1-bit, 1.5-bit or 2-bit Send delay : 0 to 500 ms Open Windows Device Manager to check the communication port to be used. Communication port check A communication port must be specified in order to communicate with the PF900/PF901. Communication ports vary by computer. Check as shown below. Click Go to Device manager button to open Device manager. Click + next to Ports (COM & LPT) to display the ports. Click For loader communication, the number following COM in RKC USB-to-Serial Bridge (COM ) is the communication port number. To check communication port on My Computer: Right-click My Computer and open Properties Device Manager. Click + next to Ports (COM & LPT) to display the ports. IMT01D09-E1 11

12 2. Receiving the screen data message is displayed. 3. When data receipt is completed correctly, Monitor screen with PF900/PF901 data will be displayed. Direct mode is shown on the right upper side of the screen. Direct mode is shown. When communication is not possible, the warning message is displayed. Click [OK] and set correct communicate parameter settings, then retry. For the data monitoring and setting of Direct mode, refer to the 6. DATA MONITORING AND SETTING (EXAMPLE) (P. 19). 12 IMT01D09-E1

13 When File mode is selected 1. Open screen is displayed. Choose a set value file (CSV format), and click [Open] button. 2. Monitor screen is displayed. Monitor screen with data in the set value file is displayed. File mode is shown on the right upper side of the screen. File mode is shown. In File mode, it is NOT POSSIBLE to compile and save set value file (CSV format). The following operation may cause malfunction or error because error-check is not performed, so DO NOT PERFORM: Open a set value file, compile it, and execute batch setting. Batch setting in File mode is to copy parameter settings in set value file without any change (for data recovery or copy). IMT01D09-E1 13

14 5. PARTS DESCRIPTIONS AND MENU LIST 5.1 Parts Descriptions Menu bar Mode state monitor Screen transfer tab Screen transfer window Data display area [Send] button [Receive] button [Repeat] checkbox Menu bar: Select and start a function of the setting tool. For details, refer to the 5.3 Menu list (P. 17). Screen transfer window: Click a screen name in the tree display to go to the screen. Screen transfer tab: Data display area: [Send] button: [Receive] button: [Repeat] checkbox: Mode state monitor: Click a tab to go to the screen. Parameter data is displayed. In Direct mode, send and write parameter settings on the screen to PF900/PF901. [Send] button is not displayed on Monitor screen and File mode. Read out monitoring data and parameter setting data from PF900/PF901, and display. [Receive] button is not displayed on File mode. When starting the setting tool or sending data, monitoring data and parameter setting data are read out from PF900/PF901. When Monitor screen remains displayed, data is not updated. To update monitoring data and parameter setting data, click [Receive] button to read out data from PF900/PF901. Automatically update monitoring data and parameter setting data from PF900/PF901 periodically. This function is available for Monitor and Operation screens in Direct mode. To activate this function, check the [Repeat] checkbox. Mode state is displayed. File mode: Displayed when in File mode. Direct mode: Displayed when in Direct mode. RESET: Lit when PF900/PF901 is in Reset mode (RESET). RUN: Lit when PF900/PF901 is in Program control mode (RUN). FIX: Lit when PF900/PF901 is in Fixed set point control mode (FIX). MAN: Lit when PF900/PF901 is in Manual control mode (MAN). 14 IMT01D09-E1

15 5.2 Pattern Display There are two kinds of pattern display, Program pattern display and Output program pattern display. To select the pattern display type, set Output program memory on Set pattern 1 screen. Pattern display of Monitor and Operation screen Program control mode (RUN): Progress of program pattern is displayed. A segment in progress is highlighted in yellow. Reset mode (RESET): Displayed pattern is not in progress, and the first segment from the left is highlighted in yellow. Output pattern display (Segment level) Pattern display (Segment level) Segment repeat display Output program memory: NK 0: Program pattern display (No assignment) 1 to [128/Maximum number of segments] (Up to 99): Output program pattern display Pattern display scale Segment in progress (highlighted in yellow) Time signal memory display Total pattern time Output program pattern display (Output program value) Pattern display scale OUT3 OUT2 OUT1 Segment in progress (highlighted in yellow) Pattern display (Output program value) Total pattern time Pattern display scale: At Program pattern display: Setting limiter low (SL) to Setting limiter high (SH) At Output program pattern display: 5.0 to % Pattern display: At Program pattern display: Segment level At Output program pattern display: Output program Segment repeat display: Displayed on the segment number when Segment repeat is set. Time signal memory display: Time signal memory is displayed. TS1 to TS8 is displayed from top to bottom. Total pattern time: The total time of pattern is displayed (number of Pattern repeat is fixed to 1 in calculation). IMT01D09-E1 15

16 Pattern display of Set pattern 1 and Set pattern 2 screen Programmed pattern is displayed. Program pattern display is as the same as on Monitor and Operation screens, but Segments programmed and shown on the above Level and Time display are in blue. Segment which is programmed and shown on the above Level and Time display (in blue). A program pattern needs to be made and saved in P900/PF901 to display a program pattern. To create a program pattern, refer to PF900/PF901 Instruction Manual (IMR02L03-E ). 16 IMT01D09-E1

17 5.3 Menu List Commands and functions which can start from menus on Menu bar. File menu Direct mode File mode Create setting file (Controller File) [Direct mode]: Read out parameter settings from the connected PF900/PF901, and save as set value file (CSV format). Refer to the 7.1 Save Parameter Settings of PF900/PF901 in the PC (P. 28). Read file (File PC) [Direct mode, File mode]: Open set value file (CSV format) from the PC to the setting tool, and the mode will switch to File mode. Refer to the 7.2 Send Parameter Settings of Set Value File (CSV format) to PF900/PF901 by Batch Setting (P. 30). Batch setting (PC Controller) [File mode]: Copy parameter settings on the setting tool to PF900/PF901 by batch setting. Refer to the 7.2 Send Parameter Settings of Set Value File (CSV format) to PF900/PF901 by Batch Setting (P. 30)). Verify (PC Controller) [File mode]: Confirm whether parameter settings in the set value file (CSV format) is the same as those in PF900/PF901. Refer to the 7.4 Compare Parameter Settings in a Set value File (CSV format) and Those in PF900/PF901 (P. 39). Exit: Exit and close the setting tool. Setting menu Set communication parameter: Set communication parameters. For multi-drop connection, switch PF900/PF901 to communicate by changing communication address. Refer to the Communication parameter setting (P. 11). Set trend praph: Set language: Set parameters for Trend graph display. Refer to the 8. DISPLAYING TREND GRAPH (EXAMPLE) (P. 41). Select language (Japanese/English). IMT01D09-E1 17

18 Mode menu Direct mode/file mode: Select Direct or File mode. Refer to the Mode selection (P. 10). Trend graph ON/Trend graph OFF: Select Trend graph ON or OFF. Refer to the 8. DISPLAYING TREND GRAPH (EXAMPLE) (P. 41). Help manu About WinUCI-PF900: Information on a version of the setting tool. 18 IMT01D09-E1

19 6. DATA MONITORING AND SETTING (EXAMPLE) Data monitoring and setting of PF900/PF901 is available in Direct mode. In Direct mode, parameter settings in PF900/PF901 can be changed from the PC, when the PF900/PF901 is connected with the PC by communication. Direct mode WinUCI-PF900 installed PC. Monitor Click [Receive] button on each screen. Check the [Repeat] checkbox. Data setting Click [Send] button on each screen. PV TM H:M:S SV 28 PTN SEG RESET RUN FIX MAN HOLD STEP R.SET PTN END MONI PF900 SET $ 40:00 200! 1 1 DO MODE Monitor data in Direct mode In Direct mode, data of a connected PF900PF901 with PC by communication can be monitored. Example: Monitor operation status of PF900/PF Connect PF900/PF901 with the PC. 2. Start the setting tool, then click [Direct mode] button. IMT01D09-E1 19

20 3. Communication parameter screen is displayed. Change the communication parameter settings to match the PF900/PF901, then click [OK] button. For loader communication, ckeck [use loader port]. Comm port number: COM1 to COM256 Communication port check (P. 11) Device address: 0 to 99 (Maximum connections: Up to 31 controllers) Speed: 2400 bps 4800 bps 9600 bps bps bps bps Data bit length: 7-bit or 8-bit Parity: Non, Odd or Even Stop bit length: 1-bit, 1.5-bit or 2-bit Send delay : 0 to 500 ms Open Windows Device Manager to check the communication port to be used. 4. Receiving the screen data message is displayed. When data receipt is completed correctly, Monitor screen with PF900/PF901 data will be displayed. Direct mode is shown on the right upper side of the screen. Displayed data on the screen is the one which was read out from PF900/PF901 when the setting tool was started. Direct mode is shown. 20 IMT01D09-E1

21 5. Click [Operation] tab. 6. Operation screen is displayed. Set 1: PROG (Program control mode, RUN) to Operation mode transfer (XM). 7. Operation mode will be switched. Do you want to proceed? screen is displayed. Click the [OK] button. RUN lights. Lights 8. Click [Monitor] tab to go back to Monitor screen. IMT01D09-E1 21

22 9. Data on the screen is updated when going back to Monitor screen. Data of PF900/PF901 on Monitoring screen is updated when the screen is switched and goes to Monitor screen. When Monitor screen remains displayed, data on Monitor screen is not updated. To update monitoring data, click [Receive] to read out data from PF900/PF901. For parameter of Monitor, refer to the PF900/PF901 Instruction Manual (IMR02L03-E ). Update monitoring data Click the [Receive] button. The screen data is updated. Automatically update monitoring data periodically Check the [Repeat] checkbox. Monitoring data is updated from PF900/PF901 periodically. 22 IMT01D09-E1

23 Set parameter settings of PF900/PF901 in Direct mode from the PC In Direct mode, parameter settings of the communicating PF900/PF901 can be changed from the PC on each screen. Before start changing parameter settings of PF900/PF901 from the PC, save all parameter settings in the PC as set value file (CSV format). In case of trouble, parameter settings before the change can be recovered from the file. Refer to the 7.1 Save Parameter Settings of PF900/PF901 in the PC (P. 28). Example: Set event parameters by loader communication from the PC. 1. Go to Monitor screen, referring to Monitor data in Direct mode (P. 19). 2. Click [Event memory] tab. 3. Event memory screen is displayed. Change the event set value. Displayed data on the screen is the one which was read out from PF900/PF901 when the screen was switched. On screens for parameter setting, when the screen is switched to or data is sent, data is read out from PF900/PF901. However, on the following screens, once data was read out from PF900/PF901, data is not updated by switching a screen. To update parameter setting data, click [Receive] to read out data from PF900/PF901. Set pattern 1 screen Set pattern 2 screen Time signal screen PID memory screen Event memory screen Wait memory screen Output program memory screen While setting data of PF900/PF901 in Direct mode, DO NOT change data of PF900/PF901 by other means such as front key operation or using other communication function to prevent data discrepancy between data in PF900/PF901 and those in the setting tool. For parameter of Event setting, refer to the PF900/PF901 Instruction Manual (IMR02L03-E ). IMT01D09-E1 23

24 Setting procedure of data Click a row of the Event memory group number to be changed. Event memory group number Event set values of the selected Event memory group number is displayed at the edit area. Click and change the event set value at the edit area. 4. After new settings are entered, click [Send]. Sending the screen data message is displayed. Sending the screen data message 5. When the data send is completed correctly, the new settings are written and saved in PF900/PF901. When send error occurs, data items which are not sent (set) will be displayed in window. Some data are sent to PF900/PF901 automatically after entering input area. In this case, [Send] button is not necessary to be clicked. 24 IMT01D09-E1

25 7. SAVE PARAMETER SETTING DATA, AND USE BATCH SETTING (EXAMPLE) By using the setting tool, parameter setting data of PF900/PF901 can be saved in the PC, or parameter setting data in a set value file (CSV format) can be sent by batch setting. The setting tool can check if there is any setting data discrepancy between a set value file and PF900/PF901. This chapter explains usage examples. Example 1: Save parameter settings of PF900/PF901 in the PC For Operation procedure, refer to the section 7.1 (P. 28). WinUCI-PF900 installed PC. Save as a set value file (CSV format). Save parameter settings in the PC. Create setting file (Controller File) [Direct mode] PV TM H:M:S SV 28 PTN SEG RESET RUN FIX MAN HOLD STEP R.SET PTN END MONI PF900 SET $ 40:00 200! 1 1 DO MODE Example 2: Send parameter settings of set value file (CSV format) to PF900/PF901 by batch setting Copy parameter settings in set value file without any change (for data recovery or copy) in File mode. This is for copy or recovery of parameter settings. For Operation procedure, refer to the section 7.2 (P. 30). [File mode] Open the set value file (CSV format). Read file (File PC) WinUCI-PF900 installed PC. Do not change any data Copy parameter settings in the set value file to PF900/PF901. Batch setting (PC Controller) [File mode] Parameter settings to be sent can be chosen PV TM H:M:S SV 28 PTN SEG RESET RUN FIX MAN HOLD STEP R.SET PTN END MONI PF900 SET $ 40:00 200! 1 1 DO MODE Parameter setting data of the set value file (CSV format) is copied and saved. Do not change any data in File mode. It is NOT POSSIBLE to save as set value file (CSV format). The following operation may cause malfunction or error because error-check is not performed, so DO NOT PERFORM: Open a set value file, compile it, and execute batch setting. IMT01D09-E1 25

26 Example 3: Copy parameter settings of the PF900/PF901 to other PF900/PF901 Read out parameter setting data from the original PF900/PF901, and save in the PC as set value file (CSV format). Then, open the set value file (without any change) and send data to a new PF900/PF901 using batch-setting to copy the same data as the original. For Operation procedure, refer to the section 7.3 (P. 34). Original WinUCI-PF900 installed PC. Save as a set value file (CSV format). Save parameter setting data in the PC. Create setting file (Controller File) [Direct mode] PV TM H:M:S SV 28 PTN SEG RESET RUN FIX MAN HOLD STEP R.SET PTN END MONI PF900 SET $ 40:00 200! 1 1 DO MODE [File mode] Open the set value file (CSV format). Read file (File PC) WinUCI-PF900 installed PC. Do not change any data Copy parameter settings in the set value file to PF900/PF901. Batch setting (PC Controller) [File mode] Parameter settings to be sent can be chosen PV TM H:M:S SV 28 PTN SEG RESET RUN FIX MAN HOLD STEP R.SET PTN END MONI PF900 New $ 40:00 200! 1 1 DO SET MODE The same data as the original is copied. Do not change any data in File mode. It is NOT POSSIBLE to save as set value file (CSV format). The following operation may cause malfunction or error because error-check is not performed, so DO NOT PERFORM: Open a set value file, compile it, and execute batch setting. 26 IMT01D09-E1

27 Example 4: Compare parameter settings in a set value file (CSV format) and those in PF900/PF901 For Operation procedure, refer to the section 7.4 (P. 39). [File mode] Open the set value file (CSV format). Read file (File PC) WinUCI-PF900 installed PC. Do not change any data Compare parameter setting data from the set value file with those from PF900/PF901. Verify (PC Controller) [File mode] PV TM H:M:S SV 28 PTN SEG $ 40:00 200! 1 1 DO RESET RUN FIX MAN HOLD STEP R.SET PTN END MONI SET MODE PF900 Comparison result is displayed. WinUCI-PF900 installed PC. IMT01D09-E1 27

28 7.1 Save Parameter Settings of PF900/PF901 in the PC 1. Connect PF900/PF901 with the PC. 2. Start the setting tool, then click [Direct mode] button. 3. Communication parameter screen is displayed. Change the communication parameter settings to match the PF900/PF901, then click [OK] button. For loader communication, ckeck [use loader port]. Comm port number: COM1 to COM256 Communication port check (P. 11) Device address: 0 to 99 (Maximum connections: Up to 31 controllers) Speed: 2400 bps 4800 bps 9600 bps bps bps bps Data bit length: 7-bit or 8-bit Parity: Non, Odd or Even Stop bit length: 1-bit, 1.5-bit or 2-bit Send delay : 0 to 500 ms Open Windows Device Manager to check the communication port to be used. 4. Receiving the screen data message is displayed. When data receipt is completed correctly, Monitor screen with PF900/PF901 data will be displayed. 28 IMT01D09-E1

29 5. On Monitor screen, select Menu File Create setting file(controller File) on Menu bar. 6. Warning screen is displayed, and click [OK] button. 7. Save as screen is displayed. Select a folder, enter a file name, and click [Save] button. 8. Creating file message is displayed. To discontinue creating set value file, click [Cancel] button. It may take more than 5 minutes to create set value file when PF900/PF901 is the state of factory setting. 9. When the data receipt is completed correctly, parameter setting data of PF900/PF901 is saved as set value file (CSV format). IMT01D09-E1 29

30 7.2 Send Parameter Settings of Set Value File (CSV format) to PF900/PF901 by Batch Setting Send parameter settings in set value file without any change (for data recovery or copy) to PF900/PF901 in File mode. This is for copy or recovery of parameter settings. Do not change any data in File mode. It is NOT POSSIBLE to save as set value file (CSV format). The following operation may cause malfunction or error because error-check is not performed, so DO NOT PERFORM: Open a set value file, compile it, and execute batch setting. Batch setting is possible when a PF900/PF901 has the same specifications as the original PF900/PF901 from which the set value file (CSV format) was created. Step 1: Open the set value file (CSV format). 1. Connect PF900/PF901 with the PC. 2. Start the setting tool, then click [File mode] button. When the setting tool is already open, select Menu File Read File (File PC) on Menu bar. 30 IMT01D09-E1

31 3. Open screen is displayed. Choose a set value file (CSV format), and click [Open] button. 4. Parameter settings in the set value file (CSV format) are displayed on the screen. Step 2: Send parameter settings to PF900/PF901 by batch setting 1. On Monitor screen, select Menu File Batch setting(pc Controller) on Menu bar. 2. Batch setting-set item selection screen is displayed. Check item checkboxes which are sent to PF900/PF901 by batch setting, then click [OK] button. IMT01D09-E1 31

32 3. Communication parameter screen is displayed. Change the communication parameter settings to match the PF900/PF901, then click [OK] button. For loader communication, ckeck [use loader port]. 4. Batch setting message is displayed. Comm port number: COM1 to COM256 Communication port check (P. 11) Device address: 0 to 99 (Maximum connections: Up to 31 controllers) Speed: 2400 bps 4800 bps 9600 bps bps bps bps Data bit length: 7-bit or 8-bit Parity: Non, Odd or Even Stop bit length: 1-bit, 1.5-bit or 2-bit Send delay : 0 to 500 ms Open Windows Device Manager to check the communication port to be used. To discontinue batch setting, click [Cancel] button. When PF900/PF901 is in FIX mode or RUN mode, Warning message screen is displayed. Click [OK] button. It may take more than 10 minutes to send all parameter settings by batch setting. 32 IMT01D09-E1

33 5. When data send is completed correctly, all parameter settings sent to PF900/PF901 are saved in the controller, and the result is displayed in window. IMT01D09-E1 33

34 7.3 Copy Parameter Settings of the PF900/PF901 to Other F900/PF901 This operation is possible when a PF900/PF901 has the same specifications as the original PF900/PF901 from which the set value file (CSV format) was created. Example: Using loader communication, copy parameter settings of the PF900/PF901 to other PF900/PF901. Read out parameter setting data from the original PF900/PF901, and save in the PC as set value file (CSV format). Then, open the set value file (without any change) and send data to a new PF900/PF901 using batch-setting. Step 1: Save parameter settings of the PF900/PF901 in the PC as set value file (CSV format). 1. Connect the original PF900/PF901 to the PC by communication. 2. Start the setting tool, then click [Direct mode] button. 3. Communication parameter screen is displayed. Change the communication parameter settings to match the PF900/PF901, then click [OK] button. For loader communication, ckeck [use loader port]. Comm port number: COM1 to COM256 Communication port check (P. 11) Device address: 0 to 99 (Maximum connections: Up to 31 controllers) Speed: 2400 bps 4800 bps 9600 bps bps bps bps Data bit length: 7-bit or 8-bit Parity: Non, Odd or Even Stop bit length: 1-bit, 1.5-bit or 2-bit Send delay : 0 to 500 ms Open Windows Device Manager to check the communication port to be used. 4. Receiving the screen data message is displayed. When data receipt is completed correctly, Monitor screen with PF900/PF901 data will be displayed. 34 IMT01D09-E1

35 5. On Monitor screen, select Menu File Create File (Controller File) on Menu bar. 6. Warning screen is displayed, and click [OK] button. 7. Save As screen is displayed. Select a folder, enter a file name, and click [Save] button. 8. Creating file message is displayed. To discontinue creating set value file, click [Cancel] button. It may take more than 5 minutes to create set value file when PF900/PF901 is the state of factory setting. 9. When the data receipt is completed correctly, parameter setting data of PF900/PF901 is saved as set value file (CSV format). IMT01D09-E1 35

36 Step 2: Open the set value file (CSV file) which saves parameter settings of the original PF900/PF Connect a new PF900/PF901 to the PC by communication. 2. On Monitor screen, select Menu File Read File(File PC) on Menu bar. 3. Open screen is displayed. Select the set value file (CSV file) which saves parameter settings of the original PF900/PF901, the click [Open] button. 4. The parameter settings in the set value file (CSV file) is displayed on the screen. Step 3: Send and copy parameter settings on the setting tool to the new PF900/PF901 by batch setting. 1. On Monitor screen, select Menu File Batch setting(pc Controller) on Menu bar. 36 IMT01D09-E1

37 2. Batch setting-set item selection screen is displayed. Check item checkboxes which are sent to PF900/PF901 by batch setting, then click [OK] button. 3. Communication parameter screen is displayed. Change the communication parameter settings to match the PF900/PF901, then click [OK] button. For loader communication, ckeck [use loader port]. Comm port number: COM1 to COM256 Communication port check (P. 11) Device address: 0 to 99 (Maximum connections: Up to 31 controllers) Speed: 2400 bps 4800 bps 9600 bps bps bps bps Data bit length: 7-bit or 8-bit Parity: Non, Odd or Even Stop bit length: 1-bit, 1.5-bit or 2-bit Send delay : 0 to 500 ms Open Windows Device Manager to check the communication port to be used. IMT01D09-E1 37

38 4. Batch setting message is displayed. To discontinue batch setting, click [Cancel] button. When PF900/PF901 is in FIX mode or RUN mode, Warning message screen is displayed. Click [OK] button. It may take more than 10 minutes to send all parameter settings by batch setting. 5. When data send is completed correctly, all parameter settings sent to PF900/PF901 are saved in the controller, and the result is displayed in window. 38 IMT01D09-E1

39 7.4 Compare Parameter Settings in a Set value File (CSV format) and Those in PF900/PF Connect PF900/PF901 with the PC. 2. Open the set value file (CSV format), referring to Step 1: Open the set value file (CSV format) (P.30). Parameter settings in the set value file (CSV format) are displayed on the screen. 3. On Monitor screen, select Menu File Verify(PC Controller) on Menu bar. 4. The set values being read from the File to PC well be compared with the set values being sent to controller. Do you want to proceed? screen is displayed, and click [OK] button. 5. Communication parameter screen is displayed. Change the communication parameter settings to match the PF900/PF901, then click [OK] button. For loader communication, ckeck [use loader port]. Comm port number: COM1 to COM256 Communication port check (P. 11) Device address: 0 to 99 (Maximum connections: Up to 31 controllers) Speed: 2400 bps 4800 bps 9600 bps bps bps bps Data bit length: 7-bit or 8-bit Parity: Non, Odd or Even Stop bit length: 1-bit, 1.5-bit or 2-bit Send delay : 0 to 500 ms Open Windows Device Manager to check the communication port to be used. IMT01D09-E1 39

40 6. Verification message is displayed. To discontinue parameter setting data comparison, click [Cancel] button. It may take more than 5 minutes to perform parameter setting data comparison. 7. When data comparison is completed, the comparison result will be displayed in window. When there is data discrepancy, check those parameter settings. 40 IMT01D09-E1

41 8. DISPLAYING TREND GRAPH (EXAMPLE) The Trend graph screen can show Measured value (PV), Set value (SV), Manipulated output value (MV) [heat-side and cool-side]. Trend data can be saved in the PC as data record file (CSV format). Parameter name shown on the graph and current monitored value Display scale for Measured value (PV) and Set value (SV) Trend graph display area (The number of the display data: 500) Y-grid width Display scale for Manipulated output value (MV) [heat-side and cool-side] Recorded time of the oldest data (the first data from the left ) Select Trend graph ON or OFF. Currently selected ON/OFF state has a check mark Sampling cycle time and Y-grid width Recorded time of the oldest data (the first data from the right) Sampling cycle time and display scale (left/right) can be set in Graph setting screen (P. 42). To display Graph setting screen, select Menu Setting Set Trend graph on Menu bar. Display Trend graph 1. Go to Monitor screen, referring to Monitor data in Direct mode (P. 19). 2. Click [Trend graph] in Screen transfer window: 3. Trend graph screen is displayed. 4. On Trend graph screen, select Menu Setting Set trend graph on Menu bar. IMT01D09-E1 41

42 5. Trend graph setting screen is displayed. Set parameter of Trend graph. Sampling rate: Set sampling cycle time of Trend graph. Setting range: Cycle:1s (Grid: 2 minutes) Cycle:2s (Grid: 4 minutes) Cycle:3s (Grid: 5 minutes) Cycle:4s (Grid: 6 minutes) Cycle:5s (Grid: 10 minutes) Cycle:10s (Grid: 15 minutes) Cycle:15s (Grid: 30 minutes) Cycle:20s (Grid: 30 minutes) Cycle:30s (Grid: 60 minutes) Cycle:60s (Grid: 120 minutes) Measured value (PV), Set value (SV), MV1 [heat-side], MV2 [cool-side]: Line color for the item is displayed. Parameters available on the trend graph and graph colors are fixed. Other parameters can not be displayed on the trend graph. Vertical scale: Set display scale for Trend graph. File record, Data logging folder: Select Data record (logging) On or Off. To save logged data, specify a folder to save the file at [Record folder], and check the [File record] checkbox. When Trend graph function is turned on, data record (logging) starts and creates a data record file (CSV format). When Trend graph function is turned off, data record stops. The data record (logging) file is created by using the date and time when Trend graph is turned on. FP900_ _ csv Date Time 6. Click [OK] button. Trend graph is shown on Trend graph screen according to the settings. Data record (logging) started at 16:43:45 on August 6 th of IMT01D09-E1

43 7. Check the [Trend ON] checkbox, then Trend graph is started. When the box of [File record] (in Graph setting screen) is checked, data record file (CSV format) is created to save logging data. To stop Treng graph: Check the [Trend OFF] checkbox. Trend graph ON/OFF can be switched in Direct mode only. If [Trend ON/OFF] checkbox is not displayed, the setting tool is in File mode. Click [Mode] [Direct mode] on Menu bar, and switch to Direct mode. To switch Trend graph ON/OFF on screens other than [Trend graph] screen, click [Mode] [Trend graph ON], or [Trend graph OFF] on Menu bar. Displays when ON/OFF state is selectable. IMT01D09-E1 43

44 9. DISPLAY SOFTWARE VERSION INFORMATION Click [Help] [Version information] on Menu bar. About WinUCI-PF900 screen is displayed. Version number 10. EXIT THE SETTING TOOL Click [File] [Exit] on Menu bar. All Rights Reserved, Copyright 2010, RKC INSTRUMENT INC. The first edition: MAY 2010 [IMQ00] RKC INSTRUMENT INC. HEADQUARTERS: 16-6, KUGAHARA 5-CHOME, OHTA-KU TOKYO JAPAN PHONE: ( ) info@rkcinst.co.jp FAX: ( ) IMT01D09-E1 MAY 2010

Communication Setup Tool for SRZ Series Digital Controller (Win UCI-SRZ)

Communication Setup Tool for SRZ Series Digital Controller (Win UCI-SRZ) Communication Setup Tool for SRZ Series Digital Controller (Win UCI-SRZ) INSTRUCTION MANUAL IMT01D08-E1 NOTE This tool can monitor and set all the setup data of the controller (SRZ Series) including engineering

More information

Communication Setup Tool for RB Series Single Loop Controller (Win UCI-RB)

Communication Setup Tool for RB Series Single Loop Controller (Win UCI-RB) Communication Setup Tool for RB Series Single Loop Controller (Win UCI-RB) INSTRUCTION MANUAL IMT01D06-E3 NOTE This tool can monitor and set all the setup data of the controller (RB Series) including engineering

More information

Digital Controller FB100 FB400 FB900. Communication Instruction Manual IMR01W04-E6 RKC INSTRUMENT INC.

Digital Controller FB100 FB400 FB900. Communication Instruction Manual IMR01W04-E6 RKC INSTRUMENT INC. Digital Controller FB1 FB4 FB9 Communication Instruction Manual RKC INSTRUMENT INC. IMR1W4-E6 Modbus is a registered trademark of Schneider Electric. Company names and product names used in this manual

More information

Data setting software MEXE02

Data setting software MEXE02 HM-40143 Data setting software MEXE02 OPERATING MANUAL Before Use Thank you for purchasing an Oriental Motor product. This operating manual describes product handling procedures and safety precautions.

More information

DriveWizard Plus Instruction Manual

DriveWizard Plus Instruction Manual DriveWizard Plus Instruction Manual To properly use the product, read this manual thoroughly. MANUAL NO. TOEP C730600 20C Table of Contents Safety Symbols and Markings...4 Manual Overview...5 Related Manuals...5

More information

Type PUM. Instruction Manual. Parameter loader for multi-loop module-type temperature controller (PUM) Note

Type PUM. Instruction Manual. Parameter loader for multi-loop module-type temperature controller (PUM) Note Instruction Manual Type PUM Parameter loader for multi-loop module-type temperature controller (PUM) INP-TN5A0201d-E International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,

More information

OS Update. Application. User s Guide. (ClassPad OS Version 3.04)

OS Update. Application. User s Guide. (ClassPad OS Version 3.04) For ClassPad 330 E OS Update (ClassPad OS Version 3.04) Application User s Guide CASIO Education website URL http://edu.casio.com ClassPad website URL http://edu.casio.com/products/classpad/ ClassPad register

More information

INSTALLING THE PS3 XBOX READY SOFTWARE:

INSTALLING THE PS3 XBOX READY SOFTWARE: INSTALLING THE PS3 XBOX READY SOFTWARE: 1. Insert the Installation CD to CD-ROM drive and execute Ready_Setup.exe NOTE: If it is the first time for the target USB disk using under this software, the software

More information

Data editing software EZED3

Data editing software EZED3 HL-17149 Data editing software EZED3 OPERATING MANUAL Thank you for purchasing an Oriental Motor product. This Operating Manual describes product handling procedures and safety precautions. Please read

More information

INST.NO. INE-919. DI5000 Setting Software

INST.NO. INE-919. DI5000 Setting Software INST.NO. INE919 DI5000 Setting Software Table of contents 1. Introduction... 1 2. System Requirement... 3 21 Operation Condition of the Software... 3 3 How to Setup... 4 31. Installation... 4 311. New

More information

Engineering Tool for PC SDWP001 Operating Manual

Engineering Tool for PC SDWP001 Operating Manual Inverter HF-520/HF-X20 Series SF-520 Series Engineering Tool for PC SDWP001 Operating Manual 1 Manual No. DM2308E-1 Table of Contents Safety Symbols and Markings...4 Safety Notes and Instructions...4 Manual

More information

Type PUM. Instruction Manual. Parameter loader for multi-loop module-type temperature controller (For version or later) Note

Type PUM. Instruction Manual. Parameter loader for multi-loop module-type temperature controller (For version or later) Note Instruction Manual Type PUM Parameter loader for multi-loop module-type temperature controller (For version 2.2.0 or later) INP-TN5A1634a-E International Sales Div Sales Group Gate City Ohsaki, East Tower,

More information

RB100/RB400 RB500/RB700 RB900

RB100/RB400 RB500/RB700 RB900 RB SERIES Digital Temperature Controller RB/RB4 RB5/RB7 RB9 Communication Instruction Manual RKC INSTRUMENT INC. IMR2C6-E3 Modbus is a registered trademark of Schneider Electric. Company names and product

More information

User Manual version 1.4 PROG DB. DATA STORAGE PROGRAM for W SERIES weight indicators (Options: OPZWUSB_ ; OPZWDATIPC)

User Manual version 1.4 PROG DB. DATA STORAGE PROGRAM for W SERIES weight indicators (Options: OPZWUSB_ ; OPZWDATIPC) User Manual version 1.4 PROG DB DATA STORAGE PROGRAM for W SERIES weight indicators (Options: OPZWUSB_ ; OPZWDATIPC) Load Cell Central follows a policy of continuous improvement and reserves the right

More information

See Clean. Installation and Set Up Guide V with Confidence. 3M Clean-Trace Data Trending Software. 3M Food Safety

See Clean. Installation and Set Up Guide V with Confidence. 3M Clean-Trace Data Trending Software. 3M Food Safety 3M Food Safety 3M Clean-Trace Hygiene Monitoring System See Clean with Confidence 3M Clean-Trace Data Trending Software Installation and Set Up Guide V.5.03 Contents Page 3 Page 4 Page 7 Page 9 Page 11

More information

Module Type Controller SRZ. Communication Extension Module Z-COM. Host Communication Instruction Manual IMS01T23-E3 RKC INSTRUMENT INC.

Module Type Controller SRZ. Communication Extension Module Z-COM. Host Communication Instruction Manual IMS01T23-E3 RKC INSTRUMENT INC. Module Type Controller SRZ Communication Extension Module Z-COM Host Communication Instruction Manual. RKC INSTRUMENT INC. IMS1T23-E3 Modbus is a registered trademark of Schneider Electric. The name of

More information

FRENIC Visual Customizer

FRENIC Visual Customizer Instruction Manual Inverter Support Software FRENIC Visual Customizer for FRENIC-Ace series Thank you for purchasing our high-performance, multipurpose FRENIC-Ace Series inverter. This manual provides

More information

LE840/LE850. Printer Setting Tool Manual Technical Reference

LE840/LE850. Printer Setting Tool Manual Technical Reference LE840/LE850 Printer Setting Tool Manual Technical Reference Table of Contents 1. INTRODUCTION 1 SUPPORTED PRINTERS... 1 FEATURES... 1 OUTLINE OF THE FUNCTIONS... 2 NOTATION... 2 SCREENS USED IN THIS DOCUMENT...

More information

3.1 I-7560 Pin Assignment and Specifications: Introduction

3.1 I-7560 Pin Assignment and Specifications: Introduction 3.1 I-7560 Pin Assignment and Specifications: Introduction The I-7560 adds a Windows serial Com port via its USB connection and is compatible with new & legacy RS-232 devices. USB Plug and Play allows

More information

MF9300. Software setup guide

MF9300. Software setup guide MF900 Software setup guide 0000 79-0 S INTRODUCTION This manual explains how to install and configure the software that is required for the printer function of the machine. The procedure for viewing the

More information

SC100/SC200 Series Multi-Function PID Controller. Users Manual

SC100/SC200 Series Multi-Function PID Controller. Users Manual SC100/SC200 Series Multi-Function PID Controller PC CONFIGURATOR SOFTWARE Model: SCCFG Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/

More information

INST.NO. INE-893. DB600 Setting Software

INST.NO. INE-893. DB600 Setting Software INST.NO. INE893 DB600 Setting Software Table of contents 1. Introduction... 1 2. System Requirement... 3 21 Operation Condition of the Software... 3 3 How to Setup... 4 31. Installation... 4 311. New installation...

More information

6 foot USB to RS-232 Serial Adapter DB-9 Male, FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MM

6 foot USB to RS-232 Serial Adapter DB-9 Male, FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MM 6 foot USB to RS-232 Serial Adapter DB-9 Male, FTDI Chipset Product Manual Coolgear Version 1.0 January 2018 Model Number: USBG-232MM 2 USBG-232MM PRODUCT MANUAL Revision History Revision Date Author Comments

More information

USB TO SERIAL CONVERTER

USB TO SERIAL CONVERTER USB TO SERIAL CONVERTER Quick Installation Guide Windows 7/8/8.1 DA-70158 Step 1: Step 2: Insert CD Driver of this product to the CD-ROM Connect the device to a spare USB port on your PC. If there is an

More information

TM Printer Service and Support Utility for Windows Version 2.xx User s Manual (English)

TM Printer Service and Support Utility for Windows Version 2.xx User s Manual (English) TM Printer Service and Support Utility for Windows Version 2.xx User s Manual (English) Rev. B Table of Contents Introduction...1 Purpose of This Manual and Target Users... 1 Composition of This Manual...

More information

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US I-7560U/7561U/7563U User Manual USB tto RS--232//422//485 Converrtterrss Verr.. 1..0,, Decc.. 2013 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of

More information

MEXE02. Support software OPERATING MANUAL

MEXE02. Support software OPERATING MANUAL HM-60131-5 Support software MEXE02 OPERATING MANUAL This manual describes the MEXE02 Ver. 3.10 and later. The screens and operation procedures in the MEXE02 Ver. 3.10 and later differ from those in versions

More information

B-EX Series B-EX Setting Tool Operation Manual

B-EX Series B-EX Setting Tool Operation Manual TOSHIBA Label Printer B-EX Series B-EX Setting Tool Operation Manual Third Edition: March 1, 2013 Table of Contents 1. INTRODUCTION 1 SUPPORTED PRINTERS... 1 SOFTWARE LICENSE AGREEMENT... 1 FEATURES...

More information

BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING

BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING Thank you for purchasing this product. This manual explains how to install

More information

USB driver and Software Installation. UPS Monitoring and Management Software

USB driver and Software Installation. UPS Monitoring and Management Software USB driver and Software Installation UPS Monitoring and Management Software LEN.MAN.SOF.143 Rev.1.00/2008 Installing USB driver and Easy-Mon X for LEONICS UPS 1. Installing and uninstalling the USB driver

More information

MW100 CAN Bus Module Configuration Tool (MX118-CAN-M30/S1) User s Manual

MW100 CAN Bus Module Configuration Tool (MX118-CAN-M30/S1) User s Manual MW100 CAN Bus Module Configuration Tool (MX118-CAN-M30/S1) User s Manual 1 Contents Before Using the Software... 3 Explanation of Functions... 3 MX118 Part Names and Functions... 3 Operation Guide... 4

More information

Module Type Controller SRZ. Communication Extension Module Z-COM. Instruction Manual IMS01T22-E5 RKC INSTRUMENT INC.

Module Type Controller SRZ. Communication Extension Module Z-COM. Instruction Manual IMS01T22-E5 RKC INSTRUMENT INC. Module Type Controller SRZ Communication Extension Module Z-COM Instruction Manual RKC INSTRUMENT INC. IMS01T22-E5 Modbus is a registered trademark of Schneider Electric. The name of each programmable

More information

SC100/SC200 Series Multi-Function PID Controller. Users Manual

SC100/SC200 Series Multi-Function PID Controller. Users Manual SC100/SC200 Series Multi-Function PID Controller LOOP CONFIGURATION BUILDER SOFTWARE Model: SFEW3E Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510

More information

ANEMOMASTER Measuring Software for Windows MODEL

ANEMOMASTER Measuring Software for Windows MODEL ANEMOMASTER Measuring Software for Windows MODEL 6000-41 Operation Manual KANOMAX JAPAN INC. 07001 12.03 Precautions When Using Kanomax Software Products in Windows Vista or 7 1. Setting icon of the software

More information

testo Comfort Software Basic 5

testo Comfort Software Basic 5 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo Comfort Software Basic 5 Instruction manual 2 1 Contents 1 Contents 1 Contents...

More information

MULTICOM. Clarity Hardware. Code/Rev.: M110/80A Date: 8/15/2018. Fax: Petrzilkova 2583/ Prague 5

MULTICOM. Clarity Hardware. Code/Rev.: M110/80A Date: 8/15/2018. Fax: Petrzilkova 2583/ Prague 5 MULTICOM Clarity Hardware ENG Code/Rev.: M110/80A Date: 8/15/2018 Phone: +420 251 013 400 DataApex Ltd. Fax: +420 251 013 401 Petrzilkova 2583/13 clarity@dataapex.com 158 00 Prague 5 www.dataapex.com The

More information

Portico VT. Installation Guide FOR HEARTLAND MERCHANT USERS JULY 2015 V2.9

Portico VT. Installation Guide FOR HEARTLAND MERCHANT USERS JULY 2015 V2.9 Portico VT Installation Guide FOR HEARTLAND MERCHANT USERS JULY 2015 V2.9 Notice THE INFORMATION CONTAINED HEREIN IS PROVIDED TO RECIPIENT "AS IS" WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING

More information

Install Manual. P2 Software ENGLISH M0509AT5091 -FJ VQT2G26-4

Install Manual. P2 Software ENGLISH M0509AT5091 -FJ VQT2G26-4 Install Manual P2 Software M0509AT5091 -FJ ENGLISH VQT2G26-4 Contents Operating Precautions When Using Windows 1. Before Installing................................................... 3 2. Precautions in

More information

For ClassPad 300. ClassPad Manager. (ProgramLink) Limited Version. User s Guide. RJA

For ClassPad 300. ClassPad Manager. (ProgramLink) Limited Version. User s Guide.  RJA For ClassPad 300 E ClassPad Manager (ProgramLink) Limited Version User s Guide RJA510188-4 http://world.casio.com/edu_e/ Note Display examples shown in this User s Guide are intended for illustrative purposes

More information

Printer Driver Manual Label Printer Rev. 5.00

Printer Driver Manual Label Printer Rev. 5.00 Manual Label Printer Rev. 5.00 http://www.bixolon.com Introduction This printer driver Manual provides information on installation, uninstallation, detailed specifications, and usage of the printer s Windows

More information

USB Port USB Serial DB-9 RS-232 Adapter FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M

USB Port USB Serial DB-9 RS-232 Adapter FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M USB 2.0 4-Port USB Serial DB-9 RS-232 Adapter FTDI Chipset Product Manual Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M 2 USB2-4COM-M PRODUCT MANUAL Revision History Revision Date Author

More information

Mini USB to RS-232 Serial Adapter DB-9 Male Converter. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI.

Mini USB to RS-232 Serial Adapter DB-9 Male Converter. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI. Mini USB to RS-232 Serial Adapter DB-9 Male Converter Product Manual Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI 2 USBG-232MINI PRODUCT MANUAL Revision History Revision Date Author Comments

More information

Utility Software Data Connection For 62S Instruction Manual

Utility Software Data Connection For 62S Instruction Manual (E-Rev1) Utility Software Data Connection For 62S Instruction Manual Please read this instruction manual carefully before installation. LICENSE AGREEMENT READ THE TERMS OF THIS AGREEMENT CAREFULLY. Fujikura

More information

Installation Procedure of IRsolution

Installation Procedure of IRsolution 206-95080E Installation Procedure of IRsolution IRsolution Read the instruction manual thoroughly before you use the product. Keep this instruction manual for future reference. Copyright Shimadzu Corporation

More information

General Specifications

General Specifications General Specifications YSS1000 Setting Software GENERAL The YSS1000 setting software (hereinafter referred to as the YSS1000) is package software to configure the functions of the YS1000 series (hereinafter

More information

General Specifications

General Specifications General Specifications YSS1000 Setting Software Functional Enhancement GENERAL The YSS1000 setting software (hereinafter referred to as the YSS1000) is package software to configure the functions of the

More information

CyberComm Pro Data Acquisition Software Installation & User Guide

CyberComm Pro Data Acquisition Software Installation & User Guide CyberComm Pro 2.2.3 Data Acquisition Software Installation & User Guide ph 1100 and ph 2100 Bench ph and Bench ph/ion Meter Technology Made Easy... 68X090822 rev 1 Aug 2002 2 PREFACE Thank you for selecting

More information

EW SERIES SUPPORT SOFTWARE (FOR EW2C-H-NP, EW2C-H-CC) OWNER'S MANUAL (Ver. 1.0)

EW SERIES SUPPORT SOFTWARE (FOR EW2C-H-NP, EW2C-H-CC) OWNER'S MANUAL (Ver. 1.0) X435178 Ver1.0 EW SERIES SUPPORT SOFTWARE (FOR EW2C-H-NP, EW2C-H-CC) OWNER'S MANUAL (Ver. 1.0) Contents 1. Software 1-1 Overview 2 1-2 System Requirements 2 2. Before You Begin 2-1 Preparation 3 2-2 Connecting

More information

KIDS. Data Acquisition Software Package INE-333D

KIDS. Data Acquisition Software Package INE-333D INE-333D Data Acquisition Software Package KIDS Thank you for your purchase of the data acquisition software KIDS. For using this software correctly and safely, please read this instruction manual thoroughly

More information

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM CONTENTS ABOUT THE SOFTWARE BEFORE INSTALLATION INSTALLING THE SOFTWARE CONNECTING TO A COMPUTER CONFIGURING THE PRINTER DRIVER TROUBLESHOOTING Page

More information

For ClassPad 300 PLUS. ClassPad Manager. Version 2.2 (PROGRAM-LINK TM ) User s Guide.

For ClassPad 300 PLUS. ClassPad Manager. Version 2.2 (PROGRAM-LINK TM ) User s Guide. For ClassPad 300 PLUS E ClassPad Manager Version 2.2 (PROGRAM-LINK TM ) User s Guide RJA510188-4 http://world.casio.com/edu/ http://classpad.net/ Note Display examples shown in this User s Guide are intended

More information

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM 8-Port RS-232 USB to Serial Adapter Data Control Box Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM 2 USB-8COM Product Manual Revision History Revision Date Author Comments

More information

REVISIONS * The manual number is given on the bottom left of the back cover.

REVISIONS * The manual number is given on the bottom left of the back cover. REVISIONS * The manual number is given on the bottom left of the back cover. Print Date * Manual Number Revision Apr., 2002 SH (NA) -080270-A First edition Jun., 2002 SH (NA) -080270-B Correction Section

More information

User s Manual. SLP-F7M Smart Loader Package for the F7M Micro Flow Rate Liquid Flow Meter. No. CP-SP-1423E

User s Manual. SLP-F7M Smart Loader Package for the F7M Micro Flow Rate Liquid Flow Meter. No. CP-SP-1423E No. CP-SP-1423E SLP-F7M Smart Loader Package for the F7M Micro Flow Rate Liquid Flow Meter User s Manual Thank you for purchasing the Smart Loader Package. This manual contains information for ensuring

More information

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

UNIVERSAL SOFTWARE. Universal Software. Data Sheet Universal Software Data Sheet System Requirements: The minimum requirements for using the Software are: 1). Windows XP/Vista/7 2). A minimum of 512 MB RAM 3). 1 GB of hard disk space 4). Microsoft Office

More information

FRENIC Loader 3.3. Instruction Manual. Inverter Support Software. (FRENIC-Mini /Eco/Multi/Ace/MEGA/HF)

FRENIC Loader 3.3. Instruction Manual. Inverter Support Software. (FRENIC-Mini /Eco/Multi/Ace/MEGA/HF) Inverter Support Software FRENIC Loader 3.3 (FRENIC-Mini /Eco/Multi/Ace/MEGA/HF) Instruction Manual INR-SI47-1549d-E Copyright 2008-2014 Fuji Electric Co., Ltd. No part of this publication may be reproduced

More information

Boxed messages as shown below need your special attention. Read them carefully.

Boxed messages as shown below need your special attention. Read them carefully. Introduction Thank you for choosing MEQNET WINDRIVER for Lactate Pro TM 2. This Operating Manual explains how to use this software in order to obtain blood lactate data stored in lactate analyzers manufactured

More information

UG MCAP II & ecap II Smartware & USB Drivers Installation

UG MCAP II & ecap II Smartware & USB Drivers Installation MCAP II & ecap II Smartware & USB Drivers Installation Sept 4, 2008 Copyright 2008 by QEI Inc. ALL RIGHTS RESERVED NOTICE The information in this document has been carefully checked and is believed to

More information

User s Guide QL-720NW

User s Guide QL-720NW User s Guide QL-720NW Be sure to read and understand this guide before using the machine. We recommend that you keep this guide nearby for future reference. Not all models are available in all countries.

More information

SICAM SICAM FCM Configurator

SICAM SICAM FCM Configurator Preface Open Source Software SICAM SICAM FCM Configurator Table of Contents SICAM FCM Configurator 1 Index V02.10 Configuration and Operation E50417-H8940-C592-A3 i NOTE For your own safety, observe the

More information

SoftBank Wireless Assistant Desktop Assistant Client User's Guide

SoftBank Wireless Assistant Desktop Assistant Client User's Guide SoftBank Wireless Assistant Desktop Assistant Client User's Guide Ver.5.5 Rev.1.1 3 Contents Preface Introduction... 4 1 The Personal Edition Desktop Assistant... 4 2 Requirements... 4 Chapter 1 Checking

More information

WinCT-FRD Set Up _EN_ Ver for Windows 10 / Windows 8.1 / Windows 7 / Windows Vista Copyright (c) 2018 A&D Company, Limited.

WinCT-FRD Set Up _EN_ Ver for Windows 10 / Windows 8.1 / Windows 7 / Windows Vista Copyright (c) 2018 A&D Company, Limited. WinCT-FRD Set Up _EN_ Ver. 1.00 for Windows 10 / Windows 8.1 / Windows 7 / Windows Vista Copyright (c) 2018 A&D Company, Limited Setup =================================================================================

More information

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual The USB-COMi-TB USB-to-Industrial Single RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple.

More information

User Manual. Recorder of environmental conditions THBR. Version: 2.0.2

User Manual. Recorder of environmental conditions THBR. Version: 2.0.2 User Manual Recorder of environmental conditions THBR Version: 2.0.2 2 TABLE OF CONTENTS 1. INTENDED USE... 4 2. INSTALLATION... 5 2.1. System requirements... 5 2.2. Installation process... 5 2.3. Program

More information

Measurement Software for Light Scattering Digital Dust Monitor

Measurement Software for Light Scattering Digital Dust Monitor Measurement Software for Light Scattering Digital Dust Monitor MODEL S344-30 Operation Manual Please read this operation manual carefully and understand the warnings described within before operating this

More information

User s Manual. PC-Based Measurement Instruments. Setup Guide for Windows Vista IM E. 1st Edition

User s Manual. PC-Based Measurement Instruments. Setup Guide for Windows Vista IM E. 1st Edition User s Manual PC-Based Measurement Instruments Setup Guide for Windows Vista 1st Edition Thank you for purchasing the PC-Based Measurement Instruments, WE7000. This setup guide describes how to install

More information

The following steps will allow you to install and quickly begin using DevCom2000:

The following steps will allow you to install and quickly begin using DevCom2000: QUICK START DevCom2000 uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed

More information

ECLIPSE LV Series Support Tools

ECLIPSE LV Series Support Tools M374E 07.1.NF.2 (3/3) ECLIPSE LV Series Support Tools (Setup software for ECLIPSE LV series microscopes) Software Manual Introduction Thank you for purchasing the Nikon products. This manual describes

More information

Paperless Recorder VGR-B100. Series

Paperless Recorder VGR-B100. Series Paperless Recorder VGR-B100 Series CE marking RoHS compliant Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! Touch Screen Operation User friendly interface through a 5.7 inch

More information

WLAN MIERUZZO BASIC SOFTWARE

WLAN MIERUZZO BASIC SOFTWARE DK-5000 Series WLAN MIERUZZO BASIC SOFTWARE USER S MANUAL DK-5005A, DK-5010A, DK-5030A DK-5005B, DK-5010B, DK-5030B DK-5005C, DK-5010C, DK-5030C DK-5005D, DK-5010D, DK-5030D This manual was last revised

More information

Utility Software Data Connection For 22S Instruction Manual

Utility Software Data Connection For 22S Instruction Manual (E-Rev1) Utility Software Data Connection For 22S Instruction Manual Please read this instruction manual carefully before installation. LICENSE AGREEMENT READ THE TERMS OF THIS AGREEMENT CAREFULLY. Fujikura

More information

Gravimetric Gateway Quick Start Tutorial Manual

Gravimetric Gateway Quick Start Tutorial Manual MAGUIRE PRODUCTS INC. GRAVIMETRIC GATEWAY SOFTWARE Gravimetric Gateway Quick Start Tutorial Manual Computer Communications Software for the Maguire Weigh Scale Blenders INSTALLATION OPERATION MAINTENANCE

More information

INSTRUCTION MANUAL FOR GCS-300 COMMUNICATION [OPTION CODE: C5] GCSC3E

INSTRUCTION MANUAL FOR GCS-300 COMMUNICATION [OPTION CODE: C5] GCSC3E INSTRUCTION MANUAL FOR COMMUNICATION [OPTION CODE C5] GCSC3E1 2002.04 To prevent the accidents by mishandling of this controller, please arrange to give this manual into the hands of the operator who actually

More information

Handheld LPC Data Retrieval Software for Windows. Operation Manual

Handheld LPC Data Retrieval Software for Windows. Operation Manual Handheld LPC Data Retrieval Software for Windows MODEL S388-70 Operation Manual Read this manual carefully and understand the warnings described in this manual before operating the product. Keep this manual

More information

Installation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10

Installation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10 Installation Instruction for Hot Disk TPS 7 2.1 2017-05-09 1(44) Installation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10 Installation Instruction for Hot Disk TPS 7 2.1 2017-05-09 2(44)

More information

Firmware, Database, & PC Application Update Installation Instructions

Firmware, Database, & PC Application Update Installation Instructions Firmware, Database, & PC Application Update Installation Instructions IMPORTANT Please read before you begin the installation. To avoid possible errors, it is recommended to install the updates as described

More information

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4 Introduction 1 General safety instructions 2 Automatic Door Controls SIDOOR Operating Instructions Installation 3 Uninstalling the software 4 Sidoor User Software 5 HCS12 Firmware Loader 6 Sidoor Manager

More information

One Expert TM. Handheld Manager, version 1.1. User s Guide

One Expert TM. Handheld Manager, version 1.1. User s Guide One Expert TM Handheld Manager, version 1.1 User s Guide One Expert TM Handheld Manager, version 1.1 User s Guide Notice Every effort was made to ensure that the information in this document was accurate

More information

1-channel Type Temperature Controller with Built-in SSR SB1. Instruction Manual IMR02M04-E1 RKC INSTRUMENT INC.

1-channel Type Temperature Controller with Built-in SSR SB1. Instruction Manual IMR02M04-E1 RKC INSTRUMENT INC. 1-channel Type Temperature Controller with Built-in SSR SB1 Instruction Manual. RKC INSTRUMENT INC. IMR2M4-E1 Modbus is a registered trademark of Schneider Electric. Company names and product names used

More information

MRZJW3- SETUP154E. General-Purpose AC Servo Servo Configuration Software MODEL INSTALLATION GUIDE

MRZJW3- SETUP154E. General-Purpose AC Servo Servo Configuration Software MODEL INSTALLATION GUIDE General-Purpose AC Servo Servo Configuration Software MODEL MRZJW3- SETUP154E INSTALLATION GUIDE Thank you for choosing the Mitsubishi general-purpose AC servo Servo Configuration Software. To optimize

More information

LASER PRINTER. Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING

LASER PRINTER. Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING MODEL: MX-B400P LASER PRINTER Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING Keep this manual close at hand for reference

More information

REVISIONS * The manual number is given on the bottom left of the back cover.

REVISIONS * The manual number is given on the bottom left of the back cover. REVISIONS * The manual number is given on the bottom left of the back cover. Print Date * Manual Number Revision Apr., 2002 SH (NA) -080270-A First edition Jun., 2002 SH (NA) -080270-B Correction Section

More information

MISUMI SUPPORT SOFTWARE. RS-Manager. User s Manual C1 / C21 / C22 / P1 EXWM KE114. Ver. 2.00

MISUMI SUPPORT SOFTWARE. RS-Manager. User s Manual C1 / C21 / C22 / P1 EXWM KE114. Ver. 2.00 MISUMI SUPPORT SOFTWARE RS-Manager User s Manual C1 / C21 / C22 / P1 Ver. 2.00 EXWM14200 KE114 CONTENTS RS-Manager User s Manual Before getting started 1 1. About RS-Manager 2 2. Installing and uninstalling

More information

Wavy for PAS&PWR Ver. 5.0

Wavy for PAS&PWR Ver. 5.0 Kikuchi 07 22 08 Operation Manual Sequence Creation Software Kobayashi 07 22 08 Wavy for PAS&PWR Ver. 5.0 Version 5.0 Prepared: July 22, 2008 KIKUSUI ELECTRONICS CORPORATION IB01809 1 1/34 Note Before

More information

Please read and understand this instruction manual thoroughly before using this product.

Please read and understand this instruction manual thoroughly before using this product. Please read and understand this instruction manual thoroughly before using this product. For Mini-Z ASF 2.4GHz Series and dnano FX Series models I.C.S. USB Adaptor Set Manual Instruction Manual No. 82080

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING

BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING Thank you for purchasing this product. This manual explains how to install

More information

CO 2 Sensor Evaluation Board EM7160

CO 2 Sensor Evaluation Board EM7160 CO 2 Sensor Evaluation Board EM7160 1. Overview Table of Contents 2. Functions of Pins on the CO 2 Sensor Module (CDM7160) 3. Configuration and Output of the Evaluation Board (EM7160) 3-1) Configuration

More information

TOSHIBA Label Printer. BCP Setting Tool Operation Manual

TOSHIBA Label Printer. BCP Setting Tool Operation Manual TOSHIBA Label Printer BCP Setting Tool Operation Manual 3rdEdition: February 23, 2017 TABLE OF CONTENTS 1. INTRODUCTION 3 SUPPORTED PRINTERS... 3 SOFTWARE LICENSE AGREEMENT... 3 FEATURES... 4 OUTLINE OF

More information

PV101-C Configuration Software V3.2. Installation and Operations Manual Section 78

PV101-C Configuration Software V3.2. Installation and Operations Manual Section 78 PV101-C Configuration Software V3.2 Installation and Operations Manual 00-02-0797 08-18-11 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right

More information

file://c:\program Files\ACEAN\Acean Configuration Software\Online_Help_Acean_...

file://c:\program Files\ACEAN\Acean Configuration Software\Online_Help_Acean_... Page 1 of 13 SOMMAIRE 1. Generality 1.1 Wiring diagram 2. Feature description 2.1 Collective addressing Broadcast 2.2 Individual addressing 3. Getting started 3.1 System requirements 3.2 Software installation

More information

Serial 2-Port ExpressCard

Serial 2-Port ExpressCard Serial 2-Port ExpressCard User Manual Ver. 2.00 All brand names and trademarks are properties of their Respective owners. Features and Benefits Fully compliant with ExpressCard Specification 1.0 ExpressCard/34

More information

USB SERIAL ADAPTOR COM PORT INSTRUCTIONS

USB SERIAL ADAPTOR COM PORT INSTRUCTIONS USB SERIAL ADAPTOR COM PORT INSTRUCTIONS No part of this work covered by the copyright hereon may be reproduced, copied, transferred or distributed in any form or by any means -- graphic, electronic, or

More information

UPort 2000 Series User s Manual

UPort 2000 Series User s Manual User s Manual Second Edition, December 2012 www.moxa.com/product 2012 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be

More information

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING AND USEFUL INFORMATION Page 2 8 29 36

More information

Module Type Controller SRX Temperature Control Module for PROFIBUS X-TIO-G Instruction Manual

Module Type Controller SRX Temperature Control Module for PROFIBUS X-TIO-G Instruction Manual Module Type Controller SRX Temperature Control Module for PROFIBUS X-TIO-G Instruction Manual IMS01N0-E3 Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper

More information

testo Comfort Software Basic 5 Instruction manual

testo Comfort Software Basic 5 Instruction manual testo Comfort Software Basic 5 Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 About this document... 4 3 Specifications... 5 3.1. Use... 5 3.2. System requirements... 5 4 First steps... 6

More information

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17 User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3

More information

Eco-POWER METER Data Collection Software KW Monitor Operation Manual

Eco-POWER METER Data Collection Software KW Monitor Operation Manual Eco-POWER METER Data Collection Software KW Monitor Operation Manual Software version: KW Monitor V2.70 Issued on January 2014 Table of Contents Chapter 1 Introduction...1 Chapter 2 Main functions of KW

More information

USER S MANUAL USB TO Serial Adapter

USER S MANUAL USB TO Serial Adapter USER S MANUAL USB TO Serial Adapter 1. Introduction Congratulations on your purchase of the USB-Serial adapter. This device provides a simple and easy way to connect Universal Serial Bus (USB) and Serial

More information