Applied Biosystems Attune Cytometric Software version 1.2 Release Notes

Size: px
Start display at page:

Download "Applied Biosystems Attune Cytometric Software version 1.2 Release Notes"

Transcription

1 Applied Biosystems Attune Cytometric Software version 1.2 Release Notes Customer ( you ) must review these notes prior to installing or operating the Attune Cytometric Software version 1.2 ( Attune Software v1.2 ). Attune Software v1.2 Installation (fresh install) NOTE: You must have Administrator privileges to install this software 1. Ensure that Microsoft.NET framework 3.5 SP1 is installed prior to installing the Attune Software v1.2. This software is available from Microsoft Corporation at 2. Insert the Attune Cytometric Software CD - if the installer does not automatically start double click the file: Attune_Setup.exe 3. Click Next to proceed to the License Terms. 4. After reading and accepting the license terms by checking the checkbox, click Next, choose the destination location of the Attune Software v1.2 (default location recommended) and click Next twice. 5. When the installation is complete click Finish. NOTE: The USB driver must also be installed to operate the cytometer from the computer. Upon first connecting with the instrument, user will be instructed to locate the USB device driver. Please follow instructions from the Installation Guide to complete the driver setup. NOTE: When first starting Attune Software v1.2, the default Username is Admin and the default Password is password. Reset as required. Upgrading from a previous Attune Cytometric Software version 1. If the Attune Software v1.2 is installed on a machine with an existing installation of an earlier version of the Attune Cytometric Software, DO NOT uninstall the existing software. 2. Prior to installation, backup the user folder in the Applied Biosystems Attune software directory as a precaution. 6. Insert the Attune Cytometric Software CD -- if the installer does not automatically start, open the CD contents in the Windows Explorer and double click the file: Attune_Setup.exe 3. Click Next to proceed to the License Terms. 4. After reading and accepting the license terms by checking the checkbox, click Next, choose the destination location of the Attune Software v1.2 (default location recommended) and click Next twice. 5. When the installation is complete click Finish. 6. Close all software programs (Example- Word) on the computer and shut down the computer. If the power is still on the Attune Cytometer, push and hold the power button to shut off the power. 7. Unplug the Attune Cytometer power cord for at least 15 seconds (resets the internal electronics). 8. Plug in the Attune Cytometer power cord and restart the computer. System Requirements 1

2 Recommended system: Intel Dual Core 960 OptiPlex computer with 4 GB RAM, Intel Core 2 Duo CPU E GHz processor, 500 GB of free hard disk space, 24 display with a resolution of 1920 x 1200 Windows XP Professional operating system with Service Pack 3 with Microsoft.NET 3.5 framework SP1 NOTE: The Attune Software v1.2 has not been evaluated for operation on other Microsoft operating systems. New Features and Fixes The version Attune Software v1.2 contains the following new features and fixes not found in version 1.1.2: Important Fixes Oval gates now function as expected Instrument LED lights now function as expected Density plots now display data correctly Local (plot specific) Statistics are now reported unambiguously Issue with setting voltages to maximum has been resolved Statistics and backgates derived from bent quad gates now function as expected The workspace now saves reliably Improved over-all stability Compensation Enhancements: Ability to customize the compensation workspace (range and scale) Ability to stop on a gate (Scatter or histogram) Ability to print compensation workspace Overlay and Side by Side samples are now compensated correctly Ability to Save data collected after run complete but Record not pressed Status bar now reflects that compensation is on when available Slider Bar Enhancements Improved resolution of course adjustment to allow +/- 1.0% adjustment Added fine-tune capability with shift+drag to allow +/- 0.1% adjustment Added arrow keys to increment/decrement values Added mouse over to show compensation value Populations now move in real-time FCS file format Enhancements $Spillover implemented for compensation for improved 3 rd party support Exporting legacy FCS files prompts to save compensation to FCS file Flow Rate and Total Volume are saved in FCS file Data segment now stored in floating point number data type for compatibility with FlowJo and other 3 rd party SW 2

3 Ability to export the data within a gate to FCS file FCS Viewer displays spillover matrix, flow rate and total volume Implemented Derived Gates Support for AND, OR and NOT gates Support for nested derived gates Derived Gates can be used as Back Gates, Stop Gates, and Set Population Workspace Enhancements Ability to traverse from object to object (plot/graph) in Zoom-in mode using tab and shift-tab keys LinLog scaling option with configurable linearization parameter (in Advance Tab of IS) Collection Panel Enhancements Replaced Min Volume Needed label with Total Volume Needed to account for total sample needed to run Renamed Draw Volume label with Acquisition Volume to reflect the minimum required volume Number of events recorded now matches with the user s specified stop criteria Experiment Explorer Enhancement User can now use Enter key to select an item in the Experiment Explorer User can now export FCS file by a right click on sample Line items on Experiment Explorer now occupy the full width of the Experiment Explorer panel. User can now select an item without having to point the mouse directly on the text label of the item Changed the language of Remove to Use Global Ability to Apply Global Workspace to all samples Ability to Apply Global Workspace to all samples within a specimen Performance Enhancements Faster login time Faster workspace refresh Faster time to switch between samples Faster time to rename samples Improved response to button click Improved file load time Other Improvements Instrument Serial Number support LOG file now contains software version number to assist tech support Reduced pressure on Sheath Pump to reduce clunking during rinse cycle Enhanced Levy-Jennings Report The file used to store usernames and passwords is now encrypted 3

4 Improved transaction log Removed the Y=0 line on bi-variate plots Shutdown now requires users to Logout Improved tab order and text focus in Instrument Settings/Configuration Known Issues High Priority Issues 1. If a user saves compensation settings as any name besides Default.gcs and then uses the compensation settings in a new experiment, upon logout the association of the compensation settings with that experiment is lost. 2. When slider bars are moved during acquisition, the populations move as expected but the data collected prior to the adjustment is still visible until the CLEAR button is pressed. During RECORD clear cannot be used as it will erase the previously recorded data. 3. When overlaying a file containing <250K events onto a file >250K events, the active data (>250K) will revert to an uncompensated view until F5 is pressed. This only affects the display of data when compensation is applied. 4. It is highly advised that users DO NOT import any FCS files into an experiment until all samples have been acquired. When importing FCS files into an experiment that contains compensation controls, the experiment voltages are updated to those of the imported file when they shouldn t be. If additional samples are then recorded, the voltages may differ from those used to collect the compensation controls resulting in erroneously compensated data. 5. Setting the default folder for data requires that the Users folder is manually copied to the new directory prior to setting the folder option within the Attune Software v Gate names are limited to 50 characters. When derived gates are created where the total name exceeds 50 characters, each individual gate name is truncated to 20 characters. This will most likely affect the naming of nested gates. For example, to create an AND gate comprising 5 gates named Gate1, Gate2, Gate3, Gate4, and Gate5 requires an iterative process: 1 st : Gate1 AND Gate2-15 Characters 2 nd : (Gate1 AND Gate2) AND Gate3-27 Characters 3 rd : ((Gate1 AND Gate2) AND Gate3) AND Gate4-39 Characters 4 th : (((Gate1 AND Gate2) AND Gate3) AND Gate4) AND Gate5 (((Gate1 AND Gate2) AN) AND Gate5-51 Characters Installation and User Management Issues 1. Setting the default folder for data requires that the Users folder is manually copied to the new directory prior to setting the folder option within the Attune Software v DO NOT uninstall the existing version of the Attune software before upgrading. If the Attune Software is uninstalled prior to an upgrade, all users data are programmed to remain intact but the configuration file required to populate the Experiment Explorer is deleted. As a consequence, if the Attune software is re-installed, upon login the experiments will not be visible in the Experiment Explorer. Notwithstanding, backup all user data to help prevent data loss. 4

5 Compensation Issues 1. If a user saves compensation settings to any name besides Default.gcs and then uses the compensation settings in a new experiment, upon logout the association of the compensation settings with that experiment is lost and the compensation settings will need to be reimported. 2. When slider bars are moved during acquisition, the populations move as expected but the data collected prior to the adjustment is still visible until the CLEAR button is pressed. During RECORD clear cannot be used as it will erase the previously recorded data. 3. When overlaying a file containing <250K events onto a file >250K events, the active data (>250K) will revert to an uncompensated view until F5 is pressed. This only affects the display of data when compensation is applied. 4. When using the slider bars, it is essential to click completely on the slider bar handle prior to moving in any direction. Moving the slider bar handle with improper focus results in slow performance. Correct focus can be identified by the location in which the compensation value is displayed while hovering over the handle. 5. Adjusting multiple slider bars without allowing each independent adjustment to fully update the data may result in Attune Software v1.2 instability. For example, if adjusting the X-axis slider on a plot, allow the data to fully refresh prior to adjusting the Y-axis slider. 6. If manual compensation is applied to an experiment (newly created or imported) with disabled parameters and the corresponding compensation workspaces are opened, the X-Axis of the histogram plot will display Open a Sample/FCS file to select a parameter. 7. The Use Compensation button is only available for higher level plots and does not allow toggling compensation on/off at a plot specific level. It is grayed out unless the top level plot is selected. 8. If manual compensation is applied to an experiment (newly created or imported) with disabled channels and the corresponding compensation workspace are opened, the X-axis label of the histogram plots will display Open a Sample/FCS file to select a parameter. 9. Parameters cannot be mix-and-matched to include both height and area measurements when calculating compensation. FSC and SSC are required parameters for setting up compensation. Ensure all required area or height parameters are enabled prior to starting the compensation setup. 10. Undo and delete does not function in the compensation workspace. 11. When printing the compensation workspace, the plots temporarily rearrange so that all plots can be printed without having to scale the plots to fit the page. Upon completion of the print, the plots revert to their original location. File and Data Management Issues 1. It is highly advised that users DO NOT import any FCS files into an experiment until all samples have been acquired. When importing FCS files into an experiment that contains compensation controls, the experiment voltages are updated to those of the imported file 5

6 when they shouldn t be. If additional samples are then recorded, the voltages may differ from those used to collect the compensation controls resulting in erroneously compensated data. 2. If a user opens the Instrument Settings after accepting the update to the experiment voltages (prompted for after importing a FCS file into an experiment that contains no compensation), they may be prompted with a second message indicating that the instrument settings have changed and whether they would like to save the changes. The user must confirm the changes otherwise the voltages will revert to the previously existing settings prior to the import of the new file. 3. Occasionally content in the Experiment Explorer window flutters. To stop the fluttering: expand the width of the Experiment Explorer; click the Reset Windows Layout button on the View tab; or, use the scroll bar on the right side of the Experiment Explorer to move up or down 4. When saving workspaces as a template (*.get) file, the workspace must be saved prior to template creation. Failure to save the workspace will result in a template that utilizes the last saved state of the workspace. 5. The Attune Software v1.2 does not allow renaming of an active experiment name. In order to rename an experiment, open sample from another experiment and rename the desired experiment. 6. If the user prints the Instrument Settings and does not close the PDF and tries to re-print the Instrument Settings, an error message telling the user that The process cannot access the file (Your filename) because it is being used by another process. Make sure the PDF is closed prior to re-printing. 7. Right clicking on the Experiment Explorer followed by a left click action on the Experiment Explorer will result in a ghost image of whatever object has been left clicked. A subsequent left click action will result in normal behavior. 8. Using a template that was created from a sample workspace containing overlays is not recommended. 9. Double clicking either the up or down arrows of the Experiment Explorer scroll bar will open whatever object is highlighted in the explorer tree. Acquisition and Analysis Issues 1. Custom parameters cannot be created during analysis mode. Create custom parameters prior to acquisition of data as they are written to the FCS file. 2. Gate names are limited to 50 characters. When derived gates are created where the total name exceeds 50 characters, each individual gate name is truncated to 20 characters. This will most likely affect the naming of nested gates. For example, to create an AND gate comprising 5 gates named Gate1, Gate2, Gate3, Gate4, and Gate5 requires an iterative process: 1 st : Gate1 AND Gate2-15 Characters 2 nd : (Gate1 AND Gate2) AND Gate3-27 Characters 3 rd : ((Gate1 AND Gate2) AND Gate3) AND Gate4-39 Characters 4 th : (((Gate1 AND Gate2) AND Gate3) AND Gate4) AND Gate5 6

7 (((Gate1 AND Gate2) AN) AND Gate5-51 Characters 3. If data is collected (only Run button is pressed) over a previously recorded sample, the user must switch to another sample and then re-open the previous sample to see the original recorded data on the workspace. 4. If data is collected (only Run button is pressed) over a previously recorded sample and the FCS viewer is opened, the data presented is that of the currently collected data and not of the previously recorded sample. In order to see the data corresponding to the recorded sample, the user must switch to another sample (with or without recorded data) and then re-open the previous sample to see the original recorded data. 5. If running more than 4 mls it is essential to rinse between each 4 ml aliquot; do not run more than 4 ml at a time without rinsing. Data on subsequent aliquots can be appended to the previous data by choosing Run, Record, and Append. Append is only available if you do not change samples, transit rates, or instrument settings prior to clicking Run and Record. 6. Backgates can only be applied to higher level plots (e.g.- parent, grandparent, etc) 7. In order to change the LinLog linearization parameter (found on the advance tab of the instrument settings), the global Instrument Settings must be opened to set the new value; otherwise the OK button will be grayed out. 8. When a plot s range is changed via the customize window, changes will not take effect using the Enter key. In order for the entered value to take effect, either click the Close button or set the focus elsewhere in the customize window. 9. Changing the range on a Dot Plot such that either the Y or X-axis minimum is greater than 0 will result in vertical striping on the plot when the sample is re-opened. Resizing the graph, adjusting the range or scale, and setting the plot to a different population will fix the striping issue while the sample is open. 10. Removing a title from a Dot Plot will result in horizontal striping until the plot is resized or a new title is added. 11. The maximum number of workspace objects is limited to 100 objects. 12. If a window becomes frozen or goes missing, clicking the Reset Windows Layout on the View Tab will reset the default position of all windows. Baseline, Performance Test and Levey-Jennings Issues 1. If any channel in the baseline is flagged as anything but Criteria Met the user is now warned and given a recommendation to re-run the baseline. 2. If a user proceeds to run a performance test when a baseline failed due to the inability to reach the target MFI, no delta PMT will be reported. 3. When the target MFI cannot be reached, a PMT value may be reported and consequently a delta PMT. These values should not be reported. However, the criteria is still flagged correctly as Out of Range due to the failure to reach the target MFI. 7

8 System Settings (Language, Fonts, Themes) Issues 1. At this time, the Attune Software v1.2 has only been fully tested using English (United States) as the OS language option. 2. Use of extra large system fonts is not supported and will result in truncation of text throughout the Attune Software v Do not change any system display properties while the Attune Software v1.2 is running. Changing settings such as the Windows Theme and any appearance setting while running the Attune Software v1.2 will result in software instability. 4. Certain fonts will not take effect if selected for plot titles, labels, statistics fonts, and text box fonts. Attune Software v1.2 Stability Issues 1. On rare occasions, unhandled exception errors occur during operation which requires restarting the Attune Software v1.2. If the pumps are running when one of these exceptions occurs the user will either have to immediately restart the Attune Software v1.2 and run either the startup script or stop script or turn off the instrument to avoid the pumps running beyond their stop positions. 2. Adjusting multiple slider bars without allowing each independent adjustment to fully update the data may result in Attune Software v1.2 instability. For example, if adjusting the X-axis slider on a plot, allow the data to fully refresh prior to adjusting the Y-axis slider. 3. Do not change any system display properties while the Attune Software v1.2 is running. Changing settings such as the Windows Theme and any appearance setting while running the Attune Software v1.2 will result in Attune Software v1.2 instability. Hardware Issues: 1. Connecting the waste sensor cable while leaving the waste tubing disconnected will result in increased back pressure and can damage to the fluidics system. This is true for all fluidics bottles and will result in damage or introduction of air into the system 2011 Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners. Windows and Microsoft are registered trademarks of Microsoft Corporation. Intel, Core, and Pentium are trademarks of Intel Corporation. Dell and OptiPlex are trademarks of Dell, Inc. For research use only. Not intended for any human or animal therapeutic or diagnostic use.

Customer ( you ) must review these notes prior to installing or operating the Attune NxT Software version ( Attune Software v1.1.0 ).

Customer ( you ) must review these notes prior to installing or operating the Attune NxT Software version ( Attune Software v1.1.0 ). Life Technologies Attune NxT Software version 1.1.0 Release Notes Customer ( you ) must review these notes prior to installing or operating the Attune NxT Software version 1.1.0 ( Attune Software v1.1.0

More information

Release Notes Life Technologies Attune NxT Software v2.2

Release Notes Life Technologies Attune NxT Software v2.2 Release Notes Life Technologies Attune NxT Software v2.2 In the following pages you will find instructions describing: New software features Known software/system issues with troubleshooting guidance Software

More information

Release Notes Life Technologies Attune NxT Software v2.3

Release Notes Life Technologies Attune NxT Software v2.3 Release Notes Life Technologies Attune NxT Software v2.3 In the following pages you will find instructions describing: New software features Known software/system issues with troubleshooting guidance Software

More information

Canto II Operation Protocol

Canto II Operation Protocol Canto II Operation Protocol Make sure the following actions have been taken before running your samples. Make sure the waste tank is empty and refilled with 500 ml clean (see page 15 for details) Make

More information

Release Notes Thermo Fisher Scientific Attune NxT Software v2.4

Release Notes Thermo Fisher Scientific Attune NxT Software v2.4 Release Notes Thermo Fisher Scientific Attune NxT Software v2.4 In the following pages you will find instructions describing: New software features Known software/system issues with troubleshooting guidance

More information

NovoExpress Software Guide. Software Version 1.2.4

NovoExpress Software Guide. Software Version 1.2.4 NovoExpress Software Guide Software Version 1.2.4 Table of Content 1. Introduction 6 1.1 Revision History...6 1.2 About the NovoExpress Software...6 1.3 Conventions...6 2. Installation 8 2.1 Installation

More information

Release Notes Life Technologies Attune NxT Cytometric Software v 2.0.0

Release Notes Life Technologies Attune NxT Cytometric Software v 2.0.0 Release Notes Life Technologies Attune NxT Cytometric Software v 2.0.0 In the following pages you will find instructions describing: 1. Software installation 2. New software features and fixes 3. Known

More information

FACSLyric TM General User instructions

FACSLyric TM General User instructions flowkon Flow Cytometry User Instructions at the University of Konstanz FACSLyric TM General User instructions In BD FACSuite software, you can measure and analyze samples using either assays or experiments.

More information

FACSLSRFortessa SORP QUICK REFERENCE GUIDE

FACSLSRFortessa SORP QUICK REFERENCE GUIDE FACSLSRFortessa SORP QUICK REFERENCE GUIDE INSTRUMENT: 1. The computer is left on at all times. Note: If not Username: Administrator Password: BDIS 2. Unlock the screen with your PPMS account (UTSW username

More information

FACSAria Fusion SORP QUICK REFERENCE GUIDE

FACSAria Fusion SORP QUICK REFERENCE GUIDE FACSAria Fusion SORP QUICK REFERENCE GUIDE INSTRUMENT: 1. The computer is left on at all times. Note: If not Username: Admin Password: BDIS 2. Ensure the flow cell access door is open. You will want to

More information

Gallios TM Quick Reference

Gallios TM Quick Reference Gallios TM Quick Reference Purpose: The purpose of this Quick Reference is to provide a simple step by step outline of the information needed to perform various tasks on the system. We begin with basic

More information

FlowJo Software Lecture Outline:

FlowJo Software Lecture Outline: FlowJo Software Lecture Outline: Workspace Basics: 3 major components 1) The Ribbons (toolbar) The availability of buttons here can be customized. *One of the best assets of FlowJo is the help feature*

More information

Import Files from Other Applications

Import Files from Other Applications Import Files from Other Applications VenturiOne allows you to import plots, gates and regions from other manufacturer s software. The supported options are Becton Dickinson experiment.zip files, Accuri.c6

More information

Spectrometer Visible Light Spectrometer V4.4

Spectrometer Visible Light Spectrometer V4.4 Visible Light Spectrometer V4.4 Table of Contents Package Contents...3 Trademarks...4 Manual Driver and Application installation...5 Manual Application Installation...6 First Start of the Application...8

More information

Log into the computer using your CU Denver username and password. Log into the DIVA software using your CU and Username and the password flow

Log into the computer using your CU Denver username and password. Log into the DIVA software using your CU and Username and the password flow Log into the computer using your CU Denver username and password Log into the DIVA software using your CU and Username and the password flow When DIVA opens, IF a CST Mismatch pop up box appears, then

More information

LSRFortessa Guide. Cell Evaluation and Therapy Core HO324

LSRFortessa Guide. Cell Evaluation and Therapy Core HO324 LSRFortessa Guide Cell Evaluation and Therapy Core HO324 Before Use: Prime the instrument twice with no tube and arm to the side Ensure that sheath is full and waste is empty To Begin: Log into ilabs tracker

More information

QUADRA-CHEK 2000 Demo User's Manual. Evaluation Unit

QUADRA-CHEK 2000 Demo User's Manual. Evaluation Unit QUADRA-CHEK 2000 Demo User's Manual Evaluation Unit English (en) 06/2018 Contents Contents 1 Fundamentals...7 2 Software Installation...11 3 Basic Operation... 17 4 Software Configuration...41 5 Quick

More information

CyAn ADP Guide. Starting Up

CyAn ADP Guide. Starting Up CyAn ADP Guide Starting Up 1. Check the sheath and waste fluids, if needed, fill and empty: 1. To fill the Sheath Tank: a. Unscrew the top of the tank labeled Sheath Tank, and set it on top of the tank.

More information

UNC Flow Cytometry Core Facility LSR II Operation 2018

UNC Flow Cytometry Core Facility LSR II Operation 2018 Reference: Startup BD FACSDiva 6 Online Course BD Training & elearning 1. Check Sheath and Waste containers: Empty Waste container in the sink Add bleach to the black mark ( ~10% final concentration).

More information

USER GUIDE TO BECKMAN COULTER FC500

USER GUIDE TO BECKMAN COULTER FC500 USER GUIDE TO BECKMAN COULTER FC500 Create a New Protocol Purpose: This procedure describes how to define the parameters and create rough analysis plots for a new experimental set-up. Some protocol templates

More information

FACCalibur Users Guide

FACCalibur Users Guide FACCalibur Users Guide FACSCalibur Start Up Procedure If the Instrument is OFF: 1. Check the sheath and waste tanks. Open the fluidics drawer (front of instrument) and check the levels of sheath fluid

More information

BD FACSMelody Cell Sorter Quick Reference Guide

BD FACSMelody Cell Sorter Quick Reference Guide BD FACSMelody Cell Sorter Quick Reference Guide This guide contains instructions for using the BD FACSMelody cell sorter with BD FACSChorus software version. and later. Workflow Overview The following

More information

Operating Instructions WhiteBoard Software for Mac 1.4

Operating Instructions WhiteBoard Software for Mac 1.4 Operating Instructions WhiteBoard Software for Mac 1.4 Please read these instructions carefully before using this product, and save this manual for future use. Panasonic Corporation 2018 Contents INTRODUCTION...

More information

Unscrew and remove the cap from the waste tank

Unscrew and remove the cap from the waste tank Stanford Cytoflex HTS User Guide 11232015 Starting up 1. Check the sheath fluid level every time you use the cytometer. This ensures that you do not run out of sheath fluid during an experiment. Replenish

More information

User Guide 701P Wide Format Solution Wide Format Scan Service

User Guide 701P Wide Format Solution Wide Format Scan Service User Guide 701P44865 6204 Wide Format Solution Wide Format Scan Service Xerox Corporation Global Knowledge & Language Services 800 Phillips Road Bldg. 845-17S Webster, NY 14580 Copyright 2006 Xerox Corporation.

More information

Technical Note. Display of BD Accuri C6 Software- Generated FCS 3.0 Files Using FlowJo for PC and Mac v7.6. Introduction

Technical Note. Display of BD Accuri C6 Software- Generated FCS 3.0 Files Using FlowJo for PC and Mac v7.6. Introduction Display of BD Accuri C6 Software- Generated FCS 3.0 Files Using FlowJo for PC and Mac v7.6 Contents 1 Introduction 2 Before You Begin 3 Using Global FlowJo Preferences 5 Usinig the Transform Button 5 Saving

More information

MagicInfo VideoWall Author

MagicInfo VideoWall Author MagicInfo VideoWall Author MagicInfo VideoWall Author User Guide MagicInfo VideoWall Author is a program designed to construct a VideoWall layout and create VideoWall content by adding various elements

More information

5 Setting Preferences 15 Preferences 15 Configure Chart Colors 16

5 Setting Preferences 15 Preferences 15 Configure Chart Colors 16 CRITERION Vantage 3 Acquire Training Manual Contents 1 Introduction 3 Collecting Data 3 2 Starting the Program 3 Logging In and Logging Out 3 Logging In 3 Logging in as an Administrator 3 Logging in as

More information

Flow Cytometry & FACS Core Facility

Flow Cytometry & FACS Core Facility ZMBH - Zentrum für Molekulare Biologie der Universität Heidelberg Flow Cytometry & FACS Core Facility BD FACSCanto TM with HTS User's Guide For authorization to use the FACSCanto II cytometer, you first

More information

Thermal Transient Test Installation and Operating Manual

Thermal Transient Test Installation and Operating Manual Thermal Transient Test Installation and Operating Manual 2705A De La Vina Street Santa Barbara, California 93105 Telephone (805) 682-0900 descon@silcom.com www. santabarbaraautomation.com Installation

More information

xponent Version 4.2 RELEASE NOTES

xponent Version 4.2 RELEASE NOTES xponent Version 4.2 RELEASE NOTES Copyright Luminex Corporation, 1996-2013. All rights reserved. Part Number: 89-30000-00-462 Disclaimer Subject to change without notice. Although prepared to ensure accuracy,

More information

Icare CLINIC Icare EXPORT Icare PATIENT app INSTRUCTION MANUAL FOR HEALTHCARE PROFESSIONALS ENGLISH

Icare CLINIC Icare EXPORT Icare PATIENT app INSTRUCTION MANUAL FOR HEALTHCARE PROFESSIONALS ENGLISH Icare CLINIC Icare EXPORT Icare PATIENT app INSTRUCTION MANUAL FOR HEALTHCARE PROFESSIONALS ENGLISH Icare CLINIC (Type: TS02), Icare EXPORT (Type: TS03) and Icare PATIENT (Type: TS04) - Instruction Manual

More information

Flow Cytometry Analysis Software. Developed by scientists, for scientists. User Manual. Version Introduction:

Flow Cytometry Analysis Software. Developed by scientists, for scientists. User Manual. Version Introduction: Flowlogic Flow Cytometry Analysis Software Developed by scientists, for scientists User Manual Version 7.2.1 Introduction: Overview, Preferences, Saving and Opening Analysis Files www.inivai.com TABLE

More information

LiveNX Upgrade Guide from v5.1.2 to v Windows

LiveNX Upgrade Guide from v5.1.2 to v Windows LIVEACTION, INC. LiveNX Upgrade Guide from v5.1.2 to v5.1.3 - Windows UPGRADE LiveAction, Inc. 3500 Copyright WEST BAYSHORE 2016 LiveAction, ROAD Inc. All rights reserved. LiveAction, LiveNX, LiveUX, the

More information

Secure Single Sign On with FingerTec OFIS

Secure Single Sign On with FingerTec OFIS Secure Single Sign On with FingerTec OFIS User Guide CONTENTS 3 1 INTRODUCTION Welcome to OFIS Gateway 4-11 2 INSTALLATION & SETUP Registering Your OFIS Gateway Installing & Setting Up Your OFIS Gateway

More information

Contents. Version 1.5 and later. Introduction Panel Descriptions Sending Still Images to the VR-4HD... 12

Contents. Version 1.5 and later. Introduction Panel Descriptions Sending Still Images to the VR-4HD... 12 VR-4HD RCS is software designed to control the VR-4HD remotely using a computer. By connecting the VR-4HD and a computer via USB, along with operating the unit from the computer, you can also save and

More information

Setup protocol for Firefly particles. On BD LSR II and LSRFortessa cytometers with single tube loader function

Setup protocol for Firefly particles. On BD LSR II and LSRFortessa cytometers with single tube loader function Setup protocol for Firefly particles On BD LSR II and LSRFortessa cytometers with single tube loader function Version 1 Last Updated May 2016 Setup protocol for Firefly particles Contents Introduction

More information

DesktopPlayer for Mac

DesktopPlayer for Mac DesktopPlayer for Mac Getting Started Version 2.6.0 November 2017 Table of Contents About this release... 3 About the Citrix DesktopPlayer for Mac solution... 3 About system memory usage... 3 DesktopPlayer

More information

Instruction Manual HIOKI Standby Power Measurement Software

Instruction Manual HIOKI Standby Power Measurement Software Instruction Manual HIOKI Standby Power Measurement Software This manual explains the free software (HIOKI Standby Power Measurement Software) for the HIOKI Power Meter series only. Please refer to the

More information

Multi-NVR Manager. Quick Start Configuration Usage

Multi-NVR Manager. Quick Start Configuration Usage Multi-NVR Manager Quick Start Configuration Usage 2014. All rights are reserved. No portion of this document may be reproduced without permission. All trademarks and brand names mentioned in this publication

More information

PS-4700/4800Series User ユーザーマニュアル Hardware Manual Manual

PS-4700/4800Series User ユーザーマニュアル Hardware Manual Manual PS-4700/4800Series シリーズ User ユーザーマニュアル GP-4000 Pro-face Manual Series Remote HMI Server Hardware Manual Manual (Atom N270/Core 2 Duo 2 Duo P8400 P8400 Pre-installed 搭載モデル Model) ) Preface Thank you for

More information

RIVA / Athena Pro-Series ECU

RIVA / Athena Pro-Series ECU RIVA / Athena Pro-Series ECU USING SOFTWARE (MAYA) Running Maya for First Time Once installed, Maya is available in the Start menu under Programs -> Maya, or from a desktop short cut, if created. The first

More information

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON TROVIS-VIEW 4 Software TROVIS 6661 Operating Instructions Electronics from SAMSON EB 6661 EN Edition January 2015 Definition of signal words DANGER! Hazardous situations which, if not avoided, will result

More information

SOFTWARE UPDATE NOTIFICATION (SUN) OMNISEC SOFTWARE v10.31: PSS

SOFTWARE UPDATE NOTIFICATION (SUN) OMNISEC SOFTWARE v10.31: PSS SOFTWARE UPDATE NOTIFICATION (SUN) OMNISEC SOFTWARE v10.31: PSS0051-05 Introduction This document details the installation and known issues with OMNISEC v10.31. This release is a maintenance release to

More information

BD FACSDiva Software Quick Reference Guide for BD FACSCanto Systems with Loader Option

BD FACSDiva Software Quick Reference Guide for BD FACSCanto Systems with Loader Option BD FACSDiva Software Quick Reference Guide for BD FACSCanto Systems with Loader Option This guide contains instructions for using BD FACSDiva software version 6 with BD FACSCanto and BD FACSCanto II systems

More information

INTRODUCTION... 3 INSTALLATION GUIDE FOR ECLIPSE 3.1 AND INSTALLATION GUIDE FOR ECLIPSE 3.3 TO

INTRODUCTION... 3 INSTALLATION GUIDE FOR ECLIPSE 3.1 AND INSTALLATION GUIDE FOR ECLIPSE 3.3 TO INTRODUCTION... 3 INSTALLATION GUIDE FOR ECLIPSE 3.1 AND 3.2... 4 INSTALLATION GUIDE FOR ECLIPSE 3.3 TO 4.3... 23 INSTALLATION GUIDE FOR ECLIPSE 4.4 OR HIGHER... 37 ECLIPSE VIEWERS... 41 DEVICES... 41

More information

VitalView Activity & Data Viewer User Manual. Version 1.3. For Technical Assistance please contact STARR Life Sciences at

VitalView Activity & Data Viewer User Manual. Version 1.3. For Technical Assistance please contact STARR Life Sciences at VitalView Activity & Data Viewer User Manual Version 1.3 For Technical Assistance please contact STARR Life Sciences at 866-978-2779 STARR Life Sciences Corp., 2015 Table of Contents 1.0 Vital View Activity

More information

Administrator Training. IDC TMWeb System. Control Room Technologies. IDC Corporation and. Presented for GM. April 2003 IDC Corporation

Administrator Training. IDC TMWeb System. Control Room Technologies. IDC Corporation and. Presented for GM. April 2003 IDC Corporation IDC TMWeb System Administrator Training Presented for GM By IDC Corporation and Control Room Technologies April 2003 IDC Corporation 2003 1 Topics of Discussion Introduction to the system Steps to setup

More information

Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION.

Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION. Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION. KALUZA C ANALYSIS SOFTWARE Kaluza C Flow Cytometry Analysis Software is built upon our successful Kaluza Analysis research use platform.

More information

LiveNX Upgrade Guide from v5.2.0 to v5.2.1

LiveNX Upgrade Guide from v5.2.0 to v5.2.1 LIVEACTION, INC. LiveNX Upgrade Guide from v5.2.0 to v5.2.1 UPGRADE LiveAction, Inc. 3500 Copyright WEST BAYSHORE 2016 LiveAction, ROAD Inc. All rights reserved. LiveAction, LiveNX, LiveUX, the LiveAction

More information

N2KExtractor. Maretron Data Extraction Software User s Manual

N2KExtractor. Maretron Data Extraction Software User s Manual N2KExtractor Maretron Data Extraction Software User s Manual Revision 3.1.6 Copyright 2017 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com

More information

Setup protocol for Firefly particles. On BD FACSCanto cytometers with single tube loader function

Setup protocol for Firefly particles. On BD FACSCanto cytometers with single tube loader function Setup protocol for Firefly particles On BD FACSCanto cytometers with single tube loader function Version 1 Last Updated May 2016 Setup protocol for Firefly particles Contents Introduction Cytometer requirements

More information

CTIMUX for Panasonic TSP

CTIMUX for Panasonic TSP CTIMUX for Panasonic TSP Installation Manual Version 1.0 3300 N. Main Street, Suite D, Anderson, SC 29621-4128 +1 (864) 642-6103 www.poltys.com 2013 All rights reserved. The information contained in this

More information

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from

More information

About XenClient Synchronizer

About XenClient Synchronizer About XenClient Synchronizer About XenClient Synchronizer About XenClient Synchronizer Synchronizer performs all the administrative tasks for the XenClient Enterprise solution. It keeps a database of all

More information

Wavy for PAS&PWR Ver. 5.0

Wavy for PAS&PWR Ver. 5.0 Kikuchi 07 22 08 Operation Manual Sequence Creation Software Kobayashi 07 22 08 Wavy for PAS&PWR Ver. 5.0 Version 5.0 Prepared: July 22, 2008 KIKUSUI ELECTRONICS CORPORATION IB01809 1 1/34 Note Before

More information

Panaboard Overlayer User's Guide. Image Capture Software for Electronic Whiteboard (Panaboard)

Panaboard Overlayer User's Guide. Image Capture Software for Electronic Whiteboard (Panaboard) Panaboard Overlayer User's Guide Image Capture Software for Electronic Whiteboard (Panaboard) Contents Introduction... 3 Functional Overview... 3 Operation Flow... 3 Abbreviations... 4 Trademarks... 4

More information

DIGIOP ELEMENTS V8.7 NVR Software-only Installation Guide

DIGIOP ELEMENTS V8.7 NVR Software-only Installation Guide DIGIOP ELEMENTS V8.7 NVR Software-only Installation Guide About this installation guide Use this document as a guide to install your DIGIOP ELEMENTS NVR software system. It includes procedures to install

More information

User Guide. VNM Software Decoder. Streaming AV Products. Software Decoder for VN-Matrix 200 Series and 225 Series Rev.

User Guide. VNM Software Decoder. Streaming AV Products. Software Decoder for VN-Matrix 200 Series and 225 Series Rev. User Guide Streaming AV Products VNM Software Decoder Software Decoder for VN-Matrix 200 Series and 225 Series 68-1995-01 Rev. B 02 12 Conventions Used in this Guide In this user guide, the following are

More information

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from

More information

Science is hard. Flow cytometry should be easy.

Science is hard. Flow cytometry should be easy. Science is hard. Flow cytometry should be easy. CFlow User Guide TABLE OF CONTENTS 1 INTRODUCTION TO CFLOW... 1 1.1 Installing CFlow... 1 1.2 Starting CFlow... 1 1.3 CFlow Workspace... 2 1.4 Opening a

More information

Calendar & Buttons Dashboard Menu Features My Profile My Favorites Watch List Adding a New Request...

Calendar & Buttons Dashboard Menu Features My Profile My Favorites Watch List Adding a New Request... remitview User Guide 1 TABLE OF CONTENTS INTRODUCTION... 3 Calendar & Buttons... 3 GETTING STARTED.... 5 Dashboard.... 7 Menu Features... 8 PROFILE.... 10 My Profile... 10 My Favorites... 12 Watch List...

More information

Compatibility with graphing calculators 32 Deleting files 34 Backing up device files 35 Working with device screens 36 Capturing device screens 36

Compatibility with graphing calculators 32 Deleting files 34 Backing up device files 35 Working with device screens 36 Capturing device screens 36 Contents Introduction to the TI Connect Window 1 TI Connect Window 1 Opening the TI Connect Window 2 Closing the TI Connect Window 4 Connecting and disconnecting TI handheld devices 4 Using Task Shortcuts

More information

LadibugTM Visual Presenter Image Software User Manual

LadibugTM Visual Presenter Image Software User Manual LadibugTM Visual Presenter Image Software User Manual 1 Contents 1. Introduction... 3 2. System requirement... 3 3. Install Ladibug TM... 4 3.1 In Windows XP/ Vista... 4 3.2 In Windows MAC... 6 4. Connection...

More information

BD CellQuest Pro Acquisition Tutorial

BD CellQuest Pro Acquisition Tutorial BD CellQuest Pro Acquisition Tutorial Introduction This tutorial guides you through a CellQuest Pro Acquisition run like the one demonstrated in the CellQuest Pro Acquisition Movie on the BD FACStation

More information

BD Influx Standard Operation Protocol - Basic Operation

BD Influx Standard Operation Protocol - Basic Operation Optimizing the drop phase BD Influx Standard Operation Protocol - Basic Operation 1. Verify the 2-tube holder with dummy 15ml tube is in place on the sort stage 2. Select 2 tube holder 2 way sort as the

More information

Getting Started in FCS Express for Previous FlowJo Users

Getting Started in FCS Express for Previous FlowJo Users Getting Started in FCS Express for Previous FlowJo Users The instructions below emphasize similarities and differences between FCS Express 5 and FlowJo v10 and are meant to serve as a translation guide

More information

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL Copyright 2002, Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted

More information

Web Self Service Administrator Guide. Version 1.1.2

Web Self Service Administrator Guide. Version 1.1.2 Version 1.1.2 Web Self Service Administrator Guide Version 1.1.2 Copyright and Trademark Notice Use of the product documented in this guide is subject to your prior acceptance of the End User License Agreement.

More information

Contributor Pro 6.2. Release Notes

Contributor Pro 6.2. Release Notes 6.2 Release Notes Contributor Pro System Requirements Operating System Contributor Pro runs on the following versions of Windows: Windows 8 Windows 7 Windows XP Professional Windows Vista Software Requirements

More information

P3PC ENZ0. Troubleshooting. (installation)

P3PC ENZ0. Troubleshooting. (installation) P3PC-3702-01ENZ0 Troubleshooting (installation) Introduction Thank you for purchasing the color image scanner ScanSnap S1500/S1500M/S1300i/S1300/ S1100 (hereinafter referred to as "the ScanSnap"). This

More information

Web Console Setup & User Guide. Version 7.1

Web Console Setup & User Guide. Version 7.1 Web Console Setup & User Guide Version 7.1 1 Contents Page Number Chapter 1 - Installation and Access 3 Server Setup Client Setup Windows Client Setup Mac Client Setup Linux Client Setup Interoperation

More information

KYOCERA Net Viewer User Guide

KYOCERA Net Viewer User Guide KYOCERA Net Viewer User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable

More information

Waters Empower 2 Service Pack G

Waters Empower 2 Service Pack G R E L E A S E N O T E S Waters Empower 2 Service Pack G Empower 2 Service Pack G enhances LDAP capabilities. These release notes also address the following information and instructions: System and software

More information

Central Monitoring by Center V2

Central Monitoring by Center V2 CHAPTER 9 Central Monitoring by Center V2 With Center V2, central monitoring station (CMS) can be deployed immediately because it brings multiple GV systems together into an integrated interface, allowing

More information

BD CellQuest Pro Software Acquisition Tutorial

BD CellQuest Pro Software Acquisition Tutorial BD CellQuest Pro Software Acquisition Tutorial This tutorial guides you through a typical acquisition using BD CellQuest Pro software. If you are already familiar with previous versions of BD CellQuest

More information

Administrator s Guide

Administrator s Guide Administrator s Guide 1995 2011 Open Systems Holdings Corp. All rights reserved. No part of this manual may be reproduced by any means without the written permission of Open Systems, Inc. OPEN SYSTEMS

More information

LEGENDplex Data Analysis Software Version 8 User Guide

LEGENDplex Data Analysis Software Version 8 User Guide LEGENDplex Data Analysis Software Version 8 User Guide Introduction Welcome to the user s guide for Version 8 of the LEGENDplex data analysis software for Windows based computers 1. This tutorial will

More information

Flowlogic. User Manual. Developed by scientists, for scientists. Version Flow Cytometry Analysis Software

Flowlogic. User Manual. Developed by scientists, for scientists. Version Flow Cytometry Analysis Software Flowlogic Flow Cytometry Analysis Software Developed by scientists, for scientists User Manual Version 7.2.1 www.inivai.com TABLE OF CONTENTS FlowLogic 7.2.1 - Introduction... 5 Layout Overview GateLogic,

More information

Performer to DP2 Hot Folder Reference Manual Rev There is only one file involved with installing the Performer to DP2 Hot Folder.

Performer to DP2 Hot Folder Reference Manual Rev There is only one file involved with installing the Performer to DP2 Hot Folder. Performer to DP2 Hot Folder Reference Manual Rev. 07.11.05 Install Files: There is only one file involved with installing the Performer to DP2 Hot Folder. The installer file is named PP2DP2_1.x.x.EXE.

More information

3M Molecular Detection System Software Upgrade/Installation Instructions

3M Molecular Detection System Software Upgrade/Installation Instructions User Manual Supplement Number: TB.342837.03 Effective Date: March 2018 Supersedes: TB.342837.02 Technology Platform: 3M Molecular Detection System Originating Location: St. Paul, MN 3M Molecular Detection

More information

FileMaker. Mobile 7. User s Guide. For Windows, Mac, Palm OS, and Pocket PC. Companion for Palm OS and Pocket PC

FileMaker. Mobile 7. User s Guide. For Windows, Mac, Palm OS, and Pocket PC. Companion for Palm OS and Pocket PC For Windows, Mac, Palm OS, and Pocket PC FileMaker Mobile 7 Companion for Palm OS and Pocket PC User s Guide 2000-2004 FileMaker, Inc. All Rights Reserved. FileMaker, Inc. 5201 Patrick Henry Drive Santa

More information

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer After completing this tutorial you will be able to: Create an Experiment with the Experiment Wizard in FCAP Array software. Export the Experiment

More information

B-Works 2 User s Guide

B-Works 2 User s Guide B-Works 2 User s Guide UMBWORKS 011413V1 Table of Contents 1. Introduction... 2 2. System Requirements... 2 3. Install B-Works 2... 3 4. Connection to the Hardware... 7 5. Start to Use B-Works 2... 7 6.

More information

Fencing Time Version 4.3

Fencing Time Version 4.3 Fencing Time Version 4.3 Server System Guide October 2017 Copyright 2017 by Fencing Time, LLC. All rights reserved. Table of Contents Table of Contents Table of Contents... 2 Chapter 1: Fencing Time Server

More information

User Manual PDUTracker

User Manual PDUTracker User Manual PDUTracker Management Software for PDU Table of Contents 1. Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. Install and Uninstall... 1 2.1. System Requirement... 1 2.2. Software

More information

KYOCERA Net Viewer 5.3 User Guide

KYOCERA Net Viewer 5.3 User Guide KYOCERA Net Viewer. User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable

More information

Wavy for PAT-T Ver. 5.2

Wavy for PAT-T Ver. 5.2 T.Shimbo 15 6 26 Operation Manual Sequence Creation Software Watanabe 15 6 26 Wavy for PAT-T Ver. 5.2 Version 5.2 Prepared: June, 2015 KIKUSUI ELECTRONICS CORPORATION IB01981 3 1/34 Note Before contacting

More information

BD Lyoplate Human Screen Analysis Instructions For analysis using FCS Express or FlowJo and heatmap representation in Excel 2007

BD Lyoplate Human Screen Analysis Instructions For analysis using FCS Express or FlowJo and heatmap representation in Excel 2007 BD Biosciences Technical Resources Page 1 For use with the BD Lyoplate Human Cell Surface Marker Screening Panel (Cat. No. 560747). Please check that your catalog numbers for the FCS Express Excel templates

More information

Network Management Software ALLNET Zone Controller

Network Management Software ALLNET Zone Controller Network Management Software ALLNET Zone Controller For ALL0558N / ALL02850N / ALL02860ND / ALL02880ND User Manual v1.0 Table of Contents 1. Installation & Un-installation... 4 1.1. Install NMS Suite...

More information

Release Notes RESOLVED NEW NEW

Release Notes RESOLVED NEW NEW 3.5.92 Resolved a bug where pages in batch review were being saved by how they were selected and not how they appeared in the list. Resolved a bug with large PDF files not saving correctly through Drag

More information

Getting Started With the Cisco PAM Desktop Software

Getting Started With the Cisco PAM Desktop Software CHAPTER 3 Getting Started With the Cisco PAM Desktop Software This chapter describes how to install the Cisco PAM desktop client software, log on to Cisco PAM, and begin configuring access control features

More information

Ocularis. Installation & Licensing Guide

Ocularis. Installation & Licensing Guide Ocularis Installation & Licensing Guide On-Net Surveillance Systems, Inc. One Blue Hill Plaza, 7 th Floor, PO Box 1555 Pearl River, NY 10965 Phone: (845) 732-7900 Fax: (845) 732-7999 Web: www.onssi.com

More information

Table of Contents. Logos Imaging Application User s Manual Version Page 1

Table of Contents. Logos Imaging Application User s Manual Version Page 1 Table of Contents About... 4 System Requirements... 5 Uninstall Previous Versions... 5 Install LIA 6.0... 6 Install the Device Drivers... 13 Register... 14 Getting Help... 14 Technical Support... 14 Workspace

More information

This means that pre revisions of AMWorks software may not be able to either open or read the newer database files.

This means that pre revisions of AMWorks software may not be able to either open or read the newer database files. AMWorks Software Version 6.4.0.10 Release Notes April 23, 2007 This document outlines: 1. AMWorks software version information and software compatibility. 2. Important installation guidelines. 3. How to

More information

CITO2 Installation & User Instructions

CITO2 Installation & User Instructions CITO2 Installation & User Instructions DD 56107 Stoneridge Electronics Ltd 1. Installation...4 1.1. System Requirements...4 1.2. Installing CITO2...4 1.3. Uninstalling CITO2...4 2. Starting and closing

More information

Webster Release Notes Rev. A, March 1, 2008

Webster Release Notes Rev. A, March 1, 2008 Webster Release Notes Rev. A, March 1, 2008 Overview This document contains release notes for PolyVision s Webster. Webster Software version 3.6 supports one of the most technologically advanced whiteboard

More information

Basic Tutorial. Data Analysis Software for Flow Cytometry Windows/Mac user documentation

Basic Tutorial. Data Analysis Software for Flow Cytometry Windows/Mac user documentation Basic Tutorial Data Analysis Software for Flow Cytometry Windows/Mac user documentation FlowJo, its tutorials, documentation and web site are copyright FlowJo, LLC 2018. All Rights Reserved. Version 2.0

More information

1 GB RAM USB port 1152x864 minimum screen resolution (1280x720 recommended) 15 GB of hard drive space for full install

1 GB RAM USB port 1152x864 minimum screen resolution (1280x720 recommended) 15 GB of hard drive space for full install System Requirements Windows Microsoft Windows XP, Vista, 7, 8 or 10 2.33GHz or faster x86-compatible processor or Intel Atom 1.6GHz or faster processor for netbooks Mac Mac OS X v10.6, v10.7, v10.8, v10.9

More information

GreenFolders User Manual

GreenFolders User Manual GreenFolders User Manual Welcome! Welcome to GreenFolders the Electronic Records Management Solution. GreenFolders allows you to store and retrieve files with many easy-to-use features for working with

More information