NO. REVISION/ISSUE 1 12/21/16 CV-1.0
NO. REVISION/ISSUE 1 01/18/17 2 07/05/17 3 07/27/17 FIRST FLOOR PLAN A-1.0
NO. REVISION/ISSUE 1 12/21/16 2 7/27/17 SECOND FLOOR PLAN A-2.0
NO. REVISION/ISSUE 1 01/11/17 2 07/05/17 3 07/24/17 FIRST FLOOR LIFE SAFETY PLAN LS-1.0
NO. REVISION/ISSUE 1 12/21/16 2 7/24/17 SECOND FLOOR LIFE SAFETY PLAN LS-2.0
(E)8"X14" S/A DUCT (E)10"X8" S/A DUCT RTU 1 (E)24"x6" S/A (E) ROOF MOUNTED GOOSENECK VENT (E) EXH. FAN (E)24"x6" S/A (E)12"x12" R/A TRX (E)12"x10" S/A 6"Ø FLEX DUCT W/ FIRE DAMPER RTU 2 TRX TRX (E)12"X8" S/A DUCT (E)10"X8" S/A DUCT TRX (E)16"X8" S/A DUCT TRX (E)22"X12" S/A DUCT (E)18"X12" S/A DUCT TRX TRX TRX (E)10"x6" S/A (E)14"x6" S/A R/A R/A (E)12"X12" S/A DUCT NO. REVISION/ISSUE 1 01/09/17 2 03/22/17 10"Ø S/A 10"Ø S/A 10"Ø S/A (E)12"x10" S/A (E)12"X12" S/A DUCT 10"Ø S/A 10"Ø S/A 10"Ø S/A (E)18"X10" EXH DUCT 11-18-16 (E) BAROMETRIC EXH DAMPER FIRST FLOOR MECHANICAL PLAN M-1.0
DRY WELL DETAIL FLEXIBLE DUCT SUPPORT DETAIL CONDENSATE DRAIN PIPING DETAIL (E)12"x12" S/A TRX (E)12"x12" S/A (E)14"X14" S/A DUCT (E)14"X14" S/A DUCT 6"Ø DUCT T TRX (E)12"Ø S/A DUCT (E)28"x6" S/A TRX 6"Ø DUCT TRX (E)8"Ø S/A DUCT (E)12"x12" S/A (E)16"x6" S/A FLEX DUCT SYSTEM DETAIL MECHANICAL PLENUM ATTACHMENT DETAIL (PER SMACNA REQUIREMENTS FLEXIBLE DUCT CONNECTION DETAIL (E)12"x12" S/A TRX (E)14"X10" S/A DUCT TRX (E)22"x6" S/A (E)8"Ø S/A DUCT TRX (E)24"x6" S/A (E)6"Ø S/A DUCT W/ V.T.R. (E)MINI-SPLIT 1 NO. REVISION/ISSUE (E)8"x8" S/A 11-18-16 RIGID DUCT HANGER DETAIL W/ V.T.R. SECOND FLOOR MECHANICAL PLAN M-2.0
RTU 1 RTU 2 AHU 2 AHU 1 NO. REVISION/ISSUE MINI-SPLIT CU 1 11-18-16 ROOFTOP MECHANICAL PLAN M-3.0
RISER DIAGRAM NO. REVISION/ISSUE 1 6/23/16 2 11/18/16 FIRST FLOOR ELECTRIC PLAN E-1.0
AMPS TYPE: NEMA 1 AMPACITY: 0 VOLTAGE: 1/240V 3Ø/4W POLE 1 TOTAL KVA 1.5 COND. SIZE WIRE SIZE GEN LI DESCRIPTION PANEL "D" CKT NO. 1 CKT NO. 3 4 50 2 3.0 WATER HEATER 5 6 125 60 MOUNTING: SURFACE DESCRIPTION MAINS: MLO LOCATION: WAREHOUSE FED FROM: MDP WIRE SIZE COND. SIZE TOTAL KVA POLE AMPS 2 RTU 2 10.0 3 70 7 8 GEN LI 1.0 1 9 10 1 1.0 GEN LI 11 12 GEN LI 1.0 1 1 1.0 GEN LI 13 14 GEN LI 1.0 1 2 2 18.75 3.0 PANEL F WATER HEATER 15 17 19 21 23 25 27 29 31 33 35 37 39 41 16 18 22 24 26 28 30 32 34 36 38 40 42 DEMAND LOAD CALCULATIONS TOTAL CONNECTED LOAD (LESS A/C) @ 100% = 9,500 VA 1ST 10,000 VA @ 100% = 9,500 VA REMAINING @ 40% = 0 VA AIR CONDITIONERS @ 65% = 6,500 VA PANEL "F" @ 100% = 18,750 VA TOTAL = 34,750 VA CURRENT PER PHASE (VA) / (240V) *1.732 = 83.60 AMPS 0 OK FEEDERS: (E)(3)3/0 W/ #4 GND. IN 2" COND. NO. REVISION/ISSUE 1 6/23/16 2 11/18/16 SECOND FLOOR ELECTRIC PLAN E-2.0
(E)10"X8" S/A DUCT RTU 1 (E) ROOF MOUNTED GOOSENECK VENT (E) EXH. FAN (E)12"x12" R/A TRX RTU 2 TRX (E)10"X8" S/A DUCT TRX (E)22"X12" S/A DUCT (E)18"X12" S/A DUCT TRX TRX (E)10"x6" S/A (E)14"x6" S/A (E)8"X14" S/A DUCT (E)24"x6" S/A (E)24"x6" S/A (E)12"x10" S/A 6"Ø FLEX DUCT W/ FIRE DAMPER TRX TRX TRX (E)12"X8" S/A DUCT (E)16"X8" S/A DUCT R/A 10"Ø S/A 10"Ø S/A R/A 10"Ø S/A 10"Ø S/A 10"Ø S/A 10"Ø S/A (E)12"x10" S/A (E)12"X12" S/A DUCT (E)12"X12" S/A DUCT (E)18"X10" EXH DUCT (E) BAROMETRIC EXH DAMPER KEY PLAN SCALE: 1/8" = 1'-0" SCOPE OF WORK AREA R/A LLE 6" LE (E)6"Ø S/A DUCT (E)8"x8" S/A W/ V.T.R. W/ V.T.R. (E)MINI-SPLIT 1 SECOND FLOOR PLUMBING ISOMETRIC PLAN SECOND FLOOR PLUMBING PLAN SCALE: 3/8" = 1'-0" NO. REVISION/ISSUE (E)18"X10" EXH DUCT FIRST FLOOR PLUMBING ISOMETRIC PLAN (E) BAROMETRIC EXH DAMPER FIRST FLOOR PLUMBING PLAN SCALE: 3/8" = 1'-0" P-1.0