Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

Similar documents
1688 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 28, NO. 11, NOVEMBER We call the conventional CTACs single-energy computed tomography

FAST KVP-SWITCHING DUAL ENERGY CT FOR PET ATTENUATION CORRECTION

Quantitative Attenuation Correction for PET/CT Using Iterative Reconstruction of Low-Dose Dual-Energy CT

Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT. y i Poisson I i (E)e R } where, b i

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

Adaptive Reconstruction Methods for Low-Dose Computed Tomography

Workshop on Quantitative SPECT and PET Brain Studies January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET

Splitting-Based Statistical X-Ray CT Image Reconstruction with Blind Gain Correction

Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation

Model-Based Iterative Reconstruction for Dual-Energy X-Ray CT Using a Joint Quadratic Likelihood Model

ML reconstruction for CT

GPU implementation for rapid iterative image reconstruction algorithm

Cardiac Dual Energy CT: Technique

Enhanced material contrast by dual-energy microct imaging

Introduction to Emission Tomography

Projection Space Maximum A Posterior Method for Low Photon Counts PET Image Reconstruction

DICOM. Supplement 188 Multi-Energy CT Imaging. DICOM Working Group 21 Computed Tomography

664 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE 2005

A Weighted Least Squares PET Image Reconstruction Method Using Iterative Coordinate Descent Algorithms

Digital Image Processing

Union of Learned Sparsifying Transforms Based Low-Dose 3D CT Image Reconstruction

Introduc)on to PET Image Reconstruc)on. Tomographic Imaging. Projec)on Imaging. Types of imaging systems

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

DUAL energy X-ray radiography [1] can be used to separate

Axial block coordinate descent (ABCD) algorithm for X-ray CT image reconstruction

Contrast Enhancement with Dual Energy CT for the Assessment of Atherosclerosis

Spectral analysis of non-stationary CT noise

STATISTICAL image reconstruction methods for X-ray

ATTENUATION correction is required for quantitatively

Reconstruction of CT Images from Sparse-View Polyenergetic Data Using Total Variation Minimization

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Ch. 4 Physical Principles of CT

Central Slice Theorem

Image Registration: Warping Without Folding

Statistical Image Reconstruction Algorithms Using Paraboloidal Surrogates for PET Transmission Scans

Spectral CT reconstruction with an explicit photon-counting detector model: a one-step approach

Introduction to Biomedical Imaging

Estimating 3D Respiratory Motion from Orbiting Views

Superiorized polyenergetic reconstruction algorithm for reduction of metal artifacts in CT images

Basics of treatment planning II

Tomographic Reconstruction

The Near Future in Cardiac CT Image Reconstruction

Noise weighting with an exponent for transmission CT

Computer-Tomography II: Image reconstruction and applications

Statistical methods for tomographic image reconstruction

Introduction to Positron Emission Tomography

arxiv: v1 [physics.med-ph] 18 Apr 2016

CT Reconstruction Using Spectral and Morphological Prior Knowledge: Application to Imaging the Prosthetic Knee

Bias-Variance Tradeos Analysis Using Uniform CR Bound. Mohammad Usman, Alfred O. Hero, Jerey A. Fessler and W. L. Rogers. University of Michigan

Ordered subsets algorithms for transmission tomography

Carbondale, IL USA; University of North Carolina Chapel Hill, NC USA; USA; ABSTRACT

PURDUE UNIVERSITY GRADUATE SCHOOL Thesis/Dissertation Acceptance

8/1/2017. Current Technology: Energy Integrating Detectors. Principles, Pitfalls and Progress in Photon-Counting-Detector Technology.

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

1. Deployment of a framework for drawing a correspondence between simple figure of merits (FOM) and quantitative imaging performance in CT.

Statistical Image Reconstruction and Motion Estimation for Image-Guided Radiotherapy

Medical Imaging BMEN Spring 2016

BME I5000: Biomedical Imaging

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Analysis of ARES Data using ML-EM

Incorporation of Prior Knowledge for Region of Change Imaging from Sparse Scan Data in Image-Guided Surgery

Q.Clear. Steve Ross, Ph.D.

Acknowledgments. Nesterov s Method for Accelerated Penalized-Likelihood Statistical Reconstruction for C-arm Cone-Beam CT.

Impact of X-ray Scatter When Using CT-based Attenuation Correction in PET: A Monte Carlo Investigation

Advanced Multi Material Decomposition of Dual Energy in Computed Tomography Image

STATISTICAL positron emission tomography (PET) image

DUAL energy CT (DECT) is a modality where one and. Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Modeling and Incorporation of System Response Functions in 3D Whole Body PET

Shiyu Xu a, Henri Schurz b, Ying Chen a,c, Abstract

Acknowledgments. High Performance Cone-Beam CT of Acute Traumatic Brain Injury

Image reconstruction for PET/CT scanners: past achievements and future challenges

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

CT imaging using energy-sensitive photon-counting detectors. Disclosure. Vision 20/20 paper

MAXIMUM a posteriori (MAP) or penalized ML image

Review of PET Physics. Timothy Turkington, Ph.D. Radiology and Medical Physics Duke University Durham, North Carolina, USA

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

Quantitative image-based spectral reconstruction for computed tomography

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Image-domain multile-material decomposition for dual-energy CT via total nuclear norm and l 0 norm

STATISTICAL image reconstruction methods have shown

Accelerating CT Iterative Reconstruction Using ADMM and Nesterov s Methods

Physical bases of X-ray diagnostics

Learning Splines for Sparse Tomographic Reconstruction. Elham Sakhaee and Alireza Entezari University of Florida

Development of a multi-axis X-ray CT for highly accurate inspection of electronic devices

Regularization for Uniform Spatial Resolution Properties in Penalized-Likelihood Image Reconstruction

Multilevel Optimization for Multi-Modal X-ray Data Analysis

NOVEL METHODS FOR SCATTER CORRECTION AND DUAL ENERGY IMAGING IN CONE-BEAM CT

Continuous and Discrete Image Reconstruction

Fast iterative beam hardening correction based on frequency splitting in computed tomography

Optimization of scanner parameters for dual energy micro-ct

Some reference material

MOTION of a patient induces artifacts such as streaks

Computer-Tomography I: Principles, History, Technology

Improving Reconstructed Image Quality in a Limited-Angle Positron Emission

x' = c 1 x + c 2 y + c 3 xy + c 4 y' = c 5 x + c 6 y + c 7 xy + c 8

Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels

Penalized-Likelihood Reconstruction for Sparse Data Acquisitions with Unregistered Prior Images and Compressed Sensing Penalties

Transcription:

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration Joonki Noh, Jeffrey A. Fessler EECS Department, The University of Michigan Paul E. Kinahan Radiology Department, The University of Washington SPIE Medical Imaging Feb. 19, 2008 1

Outline Introduction - PET/CT background - CT-based attenuation correction for PET Conventional sinogram decomposition in DE-CT Statistically motivated sinogram restoration in DE-CT - Penalized weighted least squares method - Penalized likelihood method Simulations Conclusions and future works 2/ 17

PET/CT Background I For the th ray, PET measurement is typically modeled as Spatial distribution of radioisotope activity Linear attenuation coefficient (LAC) Needed for PET image reconstruction Attenuation Transmission scans are necessary for PET attenuation correction. For this purpose, the attenuation correction factor (ACF) is defined as follows: Forward projection Evaluated at PET energy The ACF can be obtained from PET transmission scan or X-ray CT scan. 3/ 17

PET/CT Background II Benefits and a challenge of CT-based attenuation correction (CTAC): PET Transmission (511keV) X-ray Transmission (~30-140keV) High noise Long scan time Emission contamination Energy (511keV) matches PET Low noise Short scan time No emission contamination Energies do not match PET Challenge: We need to transform LACs in the range of CT energies (~30 140 kev) to LACs at the PET energy (511keV). However, there is no exact way for this transform. 4/ 17

Conventional CTAC Conventional method for CTAC is bilinear scaling (with a single-kvp source spectrum) [Blankespoor et al., IEEE TNS, 94]. Drawback: ambiguity between bone and non-bone materials with high atomic numbers, e.g., iodine contrast agent. This may cause biases in ACFs and errors can propagate from ACFs to PET images [Kinahan et al., TCRT, 06]. 5/ 17

Proposed Approaches We propose two statistically motivated approaches for DE-CT sinogram restoration, PWLS and PL methods. Why DE-CT instead of bilinear scaling? [Kinahan et al., TCRT, 06] To avoid the ambiguity between bone and iodine contrast agent Why sinogram domain instead of image domain? To compute ACF, we do not have to compute LACs directly. (To avoid potential sources of errors and to reduce computational cost) Why statistical methods? For low radiation dose, statistical methods yield more accurate ACFs. Therefore DE-CT sinogram restoration is promising for better attenuation corrected PET images!! 6/ 17

Measurement Model in DE-CT For the th source spectrum and th ray, sinogram measurement is modeled as a random variable whose mean is Known additive contributions where Sinogram measurement Polychromatic source spectrum LAC can be decomposed with component material basis functions, A simplification gives Spatial distribution of the th material density Mass attenuation coefficient 7/ 17

Conventional Sinogram Decomposition By Ignoring measurement noise and inverting the simplified expression for, we have the following estimate of : Sinogram measurement Smoothing in the radial direction Thus, we have a system of nonlinear equations where, e.g., and Solving nonlinear equations numerically produces the estimates of component sinograms, This conventional sinogram decomposition involves noise amplifying step and yields very noisy restored component sinograms and reconstructed images with streaks after performing FBP. 8/ 17

Penalized Weighted Least Squares (PWLS) I To obtain better component sinogram estimates, we use a statistically motivated method. We jointly fit the bone and soft tissue sinograms to the low and high energy log-scans. PWLS cost function Roughness penalty function where the sinogram matrix is defined as # of total rays The weight matrix (2 x 2 in DECT) are determined based on an approximate variance of. For Poisson distributed measurements and small [Fessler, IEEE TIP, 96], From this, we define the weight matrix for each ray as follows: 9/ 17

Penalized Weighted Least Squares (PWLS) II The roughness penalty function is defined as Regularization parameter First order difference in the radial direction only where the regularization parameters ( and ) control resolution/noise tradeoff. We use the optimization transfer principle to perform PWLS minimization. Using a sequence of separable quadratic surrogates, we arrive at the following equation for update: Due to the non-negativity constraint on sinogram matrix where we precompute the curvature PWLS cost function. that monotonically decreases the 10/ 17

Penalized Likelihood (PL) Approach PWLS uses the logarithmic transform to obtain, so it is suboptimal in terms of noise. To improve ACFs, we propose a PL approach that is fully based on a statistical model. Assuming Poisson distributed raw sinogram measurements leads to the PL cost function: Negative Poisson loglikelihood With the same penalty function as in PWLS, we minimize the PL cost function. Applying the optimization transfer principle yields where we precompute the curvature that monotonically decreases the PL cost function. 11/ 17

Simulations I We simulate two incident source spectra with 80kVp and 140kVp: 80 kvp Spectrum 0 20 57 140 Effective energy ) E ( I 2 140 kvp Spectrum Energy (kev) To simulate low radiation doses, we use 5 x 10 4 photons per ray for the 140kVp spectrum. The total number of rays is 140 (radius) x 128 (angle). 12/ 17

Simulations II NRMS errors obtained from the conventional sinogram decomposition with post smoothing in the radial direction, PWLS decomposition, and PL restoration NRMS error Sinogram of soft tissue Sinogram of bone Image of soft tissue Image of bone ACFs PET image ACF is defined as Sinogram restoration method ( ) Conventional decomp PWLS decomp PL restoration 21% 13% 12% 56% 34% 30% 54% 33% 31% 64% 42% 41% 22% 9% 8% 33% 19% 18% Restored component sinogram PET image is reconstructed as follows: 13/ 17

PWLS vs PL 0.21 0.2 PWLS PL 0.55 PWLS PL 0.19 0.5 0.18 0.45 0.17 0.16 0.4 0.15 0 20 40 60 80 100 0.35 0 20 40 60 80 100 For a given iteration number, PL provides lower NRMS error than PWLS. 14/ 17

Restored Component Sinograms Soft Tissue NRMS error: 21% Post-Smoothed NRMS error: 13% NRMS error: 12% Bone NRMS error: 56% NRMS error: 34% NRMS error: 30% 15/ 17

Reconstructed Component CT Images I NRMS error: 54% NRMS error: 33% NRMS error: 31% 16/ 17

Reconstructed Component CT Images II NRMS error: 64% NRMS error: 42% NRMS error: 41% 17/ 17

Reconstructed PET Images with CTAC NRMS error: 33% NRMS error: 19% NRMS error: 18% 18/ 17

Conclusions and Future Works For low-dose DE-CT, two statistically motivated sinogram restoration methods were proposed for attenuation correction of PET images. The proposed PWLS and PL methods provided lower NRMS errors than the conventional sinogram decomposition in the sinogram domain, in the image domain, and in terms of ACFs. The PL approach had the lowest NRMS errors. Future works will include - experiments with real data. - analysis for approximately uniform spatial resolution in sinograms. - comparison with bilinear scaling using iodine contrast agents. 19/ 17