GTGS 1.5 Installation Verification - Technical Note

Similar documents
Microsoft Windows Authentication Technical Note for GTGS

McAfee Install Instructions: Windows Vista

Immotec Systems, Inc. SQL Server 2008 Installation Document

Print Manager Plus 2010 Workgroup Print Tracking and Control

Immotec Systems, Inc. SQL Server 2008 Installation Document

STS INSTALLATION GUIDE

GE Healthcare. Installation Guide 3.3.1X. escriptmessenger (esm) MARCH GE Healthcare

This tutorial will guide you through the steps of setting up Synapse on Windows 7 64-Bit by utilizing Windows XP Mode.

ASSET TRACKING SYSTEM INSTALLATION GUIDE

Retrieve Download File from CSDI Installation Instructions

Media Writer. Installation Guide LX-DOC-MW5.1.9-IN-EN-REVB. Version 5.1.9

Scholastic Reading Inventory Installation Guide

Installing Sage POS and SQL

Print Audit 5 - Step by Step Walkthrough

Configuring Dynamics GP econnect with Nexonia... 1

29 March 2017 SECURITY SERVER INSTALLATION GUIDE

Surviving Sepsis Campaign

Select the Akeni Pro Server installation file that matches your operating system and double-click on the file.

Abila MIP. Human Resource Management Installation Guide

DOCUMENT TRACKING INSTALLATION GUIDE

IQSweb Reference B. SQL Server 2008 R2 and Express Installation Instructions

FASTT Math Installation Guide

FASTT Math Installation Guide

The Reading Inventory Installation Guide

Step-by-Step Guide to Ansur Executive 3.0 With or without Electronic Signatures

Installing and Using Document Distributor

DOCUMENT TRACKING INSTALLATION GUIDE

Quick Start Guide. PC, Mac, Android & ios

Digital Pack Tutorial - For Mac

Windows 95/98 Infoway Connection Instructions 1/4/2002; rev. 1/9/2002

Digital Data Manager Model 747

Sage Residential Management Versions 9.5 through Installation Guide

Controlsoft Identity and Access Management Software Controlsoft Identity Access Client Software

System 44 Installation Guide

System 44 Next Generation Installation Guide

Pearl Echo.Suite Quick Start Installation Guide

READ 180 Next Generation Installation Guide

Parallels Remote Application Server

NAPCO SECURITY TECHNOLOGIES, INC. 333 Bayview Avenue, Amityville, New York, U.S.A (631) FAX (631)

IS L02-MIGRATING TO SEP 12.1

FASTT Math Installation Guide

Document Management Upgrade Guide

WA2592 Applied Data Science and Big Data Analytics. Classroom Setup Guide. Web Age Solutions Inc. Copyright Web Age Solutions Inc.

LiveNX Upgrade Guide from v5.1.2 to v Windows

VPN Connection - Instructional Document

LiveNX Upgrade Guide from v5.2.0 to v5.2.1

System 44 Installation Guide

TEKLYNX LABEL ARCHIVE

FASTT Math Next Generation Installation Guide

BitDefender Enterprise Manager. Startup guide

December P Xerox FreeFlow Core Installation Guide

Installation Guide Command WorkStation 5.6 with Fiery Extended Applications 4.2

Digital Analytics Installation and Configuration Guide

Installing SQL Server Developer Last updated 8/28/2010

GoPrint Server Migration

Purpose. Target Audience. Windows Machine Requirements. Windows Server Core (No Desktop) Nagios XI. Monitoring Windows Using WMI

VIN Service: Multiple Connections. Mac

VPS instruction. Connecting to the Remote Desktop. Dear Client,

RELEASE NOTES LABEL ARCHIVE May, Table of Contents. System Requirements

MegaTrack. Quick Start Guide

Direct Certification FTP Setup Instructions

Appendix A: Courseware setup

R9.7 erwin License Server:

Resource: Installing Cisco Secure ACS 3.0 and greater for Windows 2000

WA1937 WebSphere Portal 7.0 Programming. Classroom Setup Guide. Web Age Solutions Inc. Copyright 2012 Web Age Solutions Inc. 1

Manual - TeamViewer 3.5

Storage Center. Enterprise Manager 5.5. Installation and Setup Guide

Kaseya 2. Installation guide. Version R8. English

READ 180 Next Generation Installation Guide

Installing the WinSCP Secure FTP Client

Pulse SCADA/HMI. Pulse Smart Login 1.1

SAS Installation Instructions Windows 2003, XP, 2000, NT. Workstation Installation Guidelines

GO-GLOBAL. Gateway API Sample. Version 4.8.2

CompuCal Version 6 Installation Guide (Windows 2008/R2) Release

Contents. 1 Drobo 5C Online User Guide Before You Begin Product Features at a Glance Checking Box Contents...

Abila MIP DrillPoint Reports. Installation Guide

Sharing Data between Applications Connecting 2 PC s running ic/icontrol

Mobile Inventory Tracking & Sales Management Software. Installation Procedure

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Fencing Time Version 4.3

Medical Office Staff User Guide Access to PowerChart

Installation Manual. Fleet Maintenance Software. Version 6.4

CYAN SECURE WEB Installing on Windows

enicq 5 Upgrade Guide

DOCUMENT HISTORY REV. NO. CHANGES DATE. 000 New Document 30 Mar Document Revision:

Multi-factor Authentication Instructions

Access Gateway Client User's Guide

OrthoFlow Server Installation Manual

EasyLobby Database Setup EasyLobby Family of Products Version 10.0

OnBase ver Thick Client Installation Instructions. Install Microsoft SQL Server 2012 Native Client

MX-Contact Instruction Sheet Setting up SQL Replication SQL 2000

LiNC-NXG for Windows 8 Professional, Windows 7 Professional, Vista Business Edition and XP Professional

Quick Links on Google Apps. Information about ACC Google Apps and Mail can be found here at

Eaglesoft 18.1 Installation Instructions

Install SQL Server 2012 with SP1 Express Edition

Interlink Express Desktop Printing Service Installation Guide

What you will need. 1 P a g e

VPN Installation Quick Setup Guide

Deposit Wizard TellerScan Installation Guide

Installation Guide. for 6.5 and all add-on modules

Transcription:

GTGS 1.5 Installation Verification - Technical Note This procedure verifies installation and proper configuration of Affymetrix GeneChip Targeted Genotyping Analysis Software (GTGS) on the Pre-Amp and Post-Amp Lab Workstations, and proper communication with the GCOS Instrument Control Workstation. It is assumed that GTGS settings have already been modified by Affymetrix to communicate with GCOS. This procedure should also be followed to verify system integrity whenever there are network configuration or security changes to the GTGS or GCOS computers. This procedure applies to the standard 3-computer configuration, each of which is connected to the local area network and has a barcode reader: This procedure does not describe how to test all the functions of GTGS, only those that interact with the other computers of the system. It is assumed that if these major functions work, the other components of the software will also work. Part Number 702326 Rev1 page 1 of 7

System configuration worksheet, for your records Who completed this worksheet Date worksheet was completed GCOS Instrument Control Workstation Computer name (on the network) Serial number GCOS version Computer Administrator name Administrator password GTGS Post-Amp Lab Workstation Computer name (on the network) Serial number GTGS version Authentication mode (NT or DB)(DB = SQL authentication) Computer Administrator name Administrator password SQL SA password GTGS Pre-Amp Lab Workstation Computer name (on the network) Serial number Is the Windows Firewall on? Are you using a Proxy server? Antivirus policy Windows updating policy Part Number 702326 Rev1 page 2 of 7

GTGS Installation Verification Procedure NOTE: The system is not considered verified unless you can CIRCLE Yes to all the checkpoints. Unless otherwise stated, do not proceed to the next checkpoint until you can answer Yes to the current checkpoint. Yes No 1. Turn on the GCOS and Lab computers. If they re already on, restart them all. Post-Amp Lab Workstation Verification Yes No 2. Log into Microsoft Windows as a user on the computer s domain (NOT Administrator on this computer ). Yes No 3. Is there a GeneChip TG Software Microsoft Internet Explorer shortcut on the Desktop? Yes No 4. Double-click on the GeneChip TG Software shortcut. Does a web page open containing the Affymetrix logo? NOTE on the following steps: By default, GTGS is configured for DB authentication, which means that when GTGS launches, the user is asked to select their name from a pull-down menu. If this is your configuration, do steps number 5 and 6 and then skip to step number 11 when completed. However, if you switched the application to use Windows NT Authentication (by following the instructions in the document Windows Authentication for GTGS Technical Note), then skip steps number 5 and 6 and continue with step number 7. Yes No 5. (DB only) Click on the GeneChip Targeted Genotyping Analysis Software link in the GeneChip TG Software web page. Does a pull-down menu appear asking for users to select their name? Note: Another dialog may appear the first time the application is launched, asking whether to integrate the application into the desktop. If it does, select No in the dialog. Yes No 6. (DB only) Select the user admin and click OK. Does the application finish starting up without any error messages? Yes No 7. (NT only) Navigate to Start Menu > right-click on My Computer > Manage. Then navigate to System Tools > Local Users and Groups > Groups. Does a local users group named GTGSusers exist on the Post-Amp Workstation? Part Number 702326 Rev1 page 3 of 7

Yes No 8. (NT only) Double-click on GTGSusers local user group. Does it contain the domain users that will use GTGS? Yes No 9. (NT only) Log out of Windows, and log in as an authorized NT user in the GTGSusers group. Click on the GeneChip Targeted Genotyping Analysis Software link in the GeneChip TG Software web page. Note: If a security warning appears, click Start to continue launching the application. If the application is running with a Trial license, click No when asked to enter the permanent license and click Accept in the End User License Agreement. Does main application window appear? Yes No 10. (NT only) Log out of Windows, and log in as an NT user who is NOT a member of GTGSusers. Launch GeneChip Targeted Genotyping Analysis Software. Does the following error message appear?: java.sql.sqlexception: [DataDirect][SQLServer JDBC Driver]Login failed for user <username>. Exception Dismiss this message, and then log out of Windows. Log in as an authorized NT user in the GTGSusers group. Yes No 11. Verify that an authorized user can still access the shared GCOS data folder: From the Windows desktop, open any folder window, and type the following into the address bar (using the actual GCOS computer name): \\GCOS_Computer_Name\GCLims\Data Press return. Can you get access to this folder without any error messages? Yes No 12. Log into the Post-Amp Workstation as a user with local administrator privileges (like Administrator ). Navigate to Start Menu > right-click on My Computer > Manage. Using the screenshot below as a guide, navigate to Services and Applications > Services > SQLSERVERAGENT service. Is the Status Started, and the Startup Type Automatic? Keep this window open Part Number 702326 Rev1 page 4 of 7

Yes No 13. Still within the Computer Management window, navigate to Services and Applications > Microsoft SQL Servers > (local) (Windows NT) > Management > SQL Server Agent > Jobs (see figure below): Right-click on the BackupGeno job, and select Start Job. When the job starts, refresh the window by right-clicking on the window containing this job and selecting Refresh. When the Status for BackupGeno is Not Running, does the Last Run Status report Succeeded? Close the Computer Management window Yes No 14. Open Microsoft Notepad on the Post-Amp Workstation, and scan in an array barcode, or any other barcode that s available. Is the cursor blinking on the next line, right below the barcode? Pre-Amp Lab Workstation Verification Yes No 15. Log into Windows as a domain user who should have access to GTGS. Is there a GeneChip TG Software Internet Explorer shortcut on the Desktop? Yes No 16. Double-click on the GeneChip TG Software shortcut. Does a web page with the Affymetrix logo open having? Yes No 17. Double-click on the GeneChip Targeted Genotyping Analysis Software link in the GeneChip TG Software web page. Note: If a security warning appears, click Start to continue launching the application. If the application is running with a Trial license, click No when asked to enter the permanent license and click Accept in the End User License Agreement. Does the application load directly to the main window? Part Number 702326 Rev1 page 5 of 7

Yes No 18. Within the application, select the Projects item in the pull-down menu below the File menu. Right-click on the Projects folder in the tree and select New Assay Project. Select a test assay panel and click OK. Name the project software verification and click Save. Expand the software verification project, and right-click on the Tracking section. See if the Register Exp Info w/ GCOS operation option appears (but do not select it): Is a GCOS operation available? (if not, the GCOS.properties file on the Post-Amp Workstation hasn t been properly configured, and you should not continue.) Yes No 19. Right-click on Tracking section of the same project and select Register Exp Info w/gcos. Do you see the message: Part Number 702326 Rev1 page 6 of 7

Yes No 20. Open Notepad on the Pre-Amp Workstation, and scan in an array barcode, or any barcode that s available. Is the cursor blinking on the next line, right below the barcode? GeneChip Instrument Workstation Verification for GTGS Yes No 21. From the GCOS Instrument Workstation, launch GCOS from Start Menu > Programs > Affymetrix. Click the Expts icon to open a new experiment window. In the Probe Array Types field in this window, does the TrueTag_3K_A array type appear in the pull-down menu? It is required for training. Yes No 22. Do you see the MegAllele Processing tool in the GeneChip Software section of the Shortcut Bar window? You may need to scroll through the tools in this window to find it. Yes No 23. Within GCOS, press the Fluidics button (next to Expts). Does the TrueTag protocol exist in the Protocol menu? Yes No 24. From the GCOS Workstation, open Start Menu > Programs > Accessories > Notepad. Scan an array barcode into Notepad, or any barcode that s available. Is the cursor blinking at the end of the barcode, on the same line? Part Number 702326 Rev1 page 7 of 7