Release Notes INCA-FLOW V4.6. Release Notes. Page 1 of 12

Similar documents
Release Notes INCA-FLOW V4.4. Release Notes. Page 1 of 13

Release Notes. INCA-QM-BASIC Add-on. Release Notes. Page 1 of 11

Release Notes INCA-RDE V1.0. Release Notes. Page 1 of 11

INCA-MIP Add-on MATLAB Integration Package for INCA 7 Release Notes V INCA-MIP Add-on. Release Notes V Page 1 of 12

MDA 8 preview SP2 Release Notes. Release Notes. Release: March, Page 1 of 8

ETAS RTA Lightweight Hypervisor for SPC58ECxxGHS v1.0.0

LABCAR-FWP V Release Notes LABCAR-FWP V Release Notes. Page 1 of 5

LABCAR-FWP V Release Notes LABCAR-FWP V Release Notes. Page 1 of 6

ES922.1 Version 1.1.0

INCA V7.1.0 Release Notes INCA V Release Notes. Release: March Page 1 of 13

HSP Update Tool V

MDA v7.2.3 Release Notes. MDA v Release Notes. Release: December Page 1 of 13

HSP Update Tool V5.9.0

HSP-SP V Release Notes HSP-SP V Release Notes. Page 1 of 7

MDA V8.3.1 Release Notes MDA V Release Notes. Release: December Page 1 of 10

ETAS CONGRA V1.3.0 Installation Guide

ES6xx Add-On & Hardware Configuration Tool V1.4.0

Daisy Chain Configuration Tool V Release Notes. Release Notes. Page 1 of 7

ETAS ASCMO 5.2 Release Notes. Release Notes. Page 1 of 12

INCA V7.2 INCA Instrument Integration Development Kit V1.2 Quick Start Guide

HSP-SP V Release Notes HSP-SP V Release Notes. Page 1 of 6

Table of Contents ================================================================

ETAS SCODE-ANALYZER Getting Started

INCA V7.2 Service Pack 01 Release Notes. Release Notes. Release: July 19, Page 1 of 20

MDA V8.3.1/1 Release Notes MDA V8.3.1/1. Release Notes. Release: January Page 1 of 11

INCA V7 Performance Tips And Tricks

INCA-FLOW Getting Started

INCA-EIP V7.2 User s Guide

INCA-LIN V6.2. User Manual

ETAS INCA V7.1 Serial Calibration with InCircuit2 INCA User s Guide Supplement

INCA-EIP (Experimental Target Integration Package) V7.0.2 User s Guide

INCA-FLEXRAY V7.2 User Manual

INCA-LIN V7.2 User s Guide

EHOOKS V4.0 PRE-RELEASE

EHOOKS V4.3 User Guide

INCA V7.2 Service Pack 2.2 Release Notes. Release Notes. Release: November Page 1 of 32

MDA Custom Map Control Creation for GPS View V1.1 Tutorial

ASCET-DEVELOPER Release Notes

INCA-ES9xx V7.0.2 Release Notes

CBAM270 XETK ECU Adapter and Power Supply Cable, pre-assembled into PG9 screwing, shield on ECU-Housing, Lemo 1B PHE - JST PHR (10fc-5fc) / Lemo 0B

INCA-FLEXRAY V6.2. User Manual

=============================================================== ===============================================================

INCA-ES5xx V Release Notes

RTA-BSW v3.0.0 RTA-BSW Getting Started Guide Status: Release

INCA-SIP User s Guide

PB4350DAC1 - D/A Module User s Guide

MDA V Release Notes MDA V Release Notes. Page 1 of 21

ETAS RTPC V Release Notes

ASCET 7.2 Getting Started Guide

ASCET-SE V6.3. EHOOKS Target User Guide

ASCET V6.2 Icon Reference Guide

ASCET V6.4. AUTOSAR to ASCET Converter User s Guide

INCA-VLINK V1.3 Getting Started

Product: XETK-T2.1 Rev : 03 Page 1 of 12. Current shipped (hardware state): C011 Current released firmware version: HSP Department MCD/PRM-H

MDA V8.2 User's Guide

RTA-OS V850E2/GHS Release Note - Version ( )

INCA-MIP V16.0 for INCA V7.1 User s Guide

ASCET-DEVELOPER 7.3 Getting Started Guide

Product: XETK-T2.2 Rev : 02 Page 1 of 12. Current shipped (hardware state): A010 Current released firmware version: HSP Department PGA/PRM-H

INCA-FLOW V4.6 - What s new? Guided Calibration for INCA

FlexRay Editor User s Guide

Current shipped hardware state: D010/01 Current released firmware version: HSP Department PGA/PRM-M2. Date Released:

PB1651ADC1 A/D Module User s Guide

INCA V7.2 Getting Started

Network Installation for ES1130 and ES1120 User s Guide

INCA-MIP V16.1 for INCA V7.2 User s Guide

Department PGA/PRM-M2. Date Released: Department NE/PJM. C h a n g e s

ETAM3 XETK/FETK ECU Adapter, SAMTEC FFSD - SAMTEC SFM (10fc - 10fc), 0m11 User s Guide

Current shipped (hardware state): C013/01 Current released firmware version: HSP Department NE/EHE3. Date Released:

ETAS ASCMO MOCA V5.1 User's Guide

ODX-LINK V1.5 ODX-FLASH V1.5 User s Guide

Current shipped (hardware state): C013/01 Current released firmware version: HSP Department PGA/PRM-M2. Date Released:

LABCAR-OPERATOR V5.4.2 User s Guide

Currently shipped for ETK-Mode: B010/01. Currently shipped for FETK-Mode: B010/01. Date Released: Department PGA/PRM-M2

Welcome to the. SACRRA Data Master Application. Administration Guide

MDA V7.2 Getting Started

ASCET Rapid Prototyping V6.4 User s Guide

Current shipped hardware state: B012/01 Current released firmware version: HSP Department NE/EHE3. Date Released:

ASCET V6.3 AUTOSAR User s Guide

LABCAR-OPERATOR V5.4.2 Getting Started

SyncFirst Standard. Quick Start Guide User Guide Step-By-Step Guide

MapMarker Plus Developer Installation Guide

ES585.1 K-Line Interface Compact. User's Guide

Instruction manual. testo easyemission Software

SICAT SUITE VERSION 1.1. Instructions for use English

Current shipped hardware state: C012/02 Current released firmware version: HSP Department NE/EHE3. Date Released:

REVISIONS * The manual number is given on the bottom left of the back cover.

EXPRESSCLUSTER X Integrated WebManager

MapMarker Plus Desktop Installation Guide

QUICK START. DevCom2000 User Manual

ASCET-SE V6.4. EHOOKS Target User Guide

Department PAC-P3. Department PAC-P3. C h a n g e s. 1.0 (10)10A010 - initial version Müller Müller

primoftp Motion Control PMC User Manual No EN-05

Soft Terminal Manual

REVISIONS * The manual number is given on the bottom left of the back cover.

INSTALLATION AND SET UP GUIDE

Unified Messenger 4.02 Installation Guide

LIN Editor User s Guide

NiceLabel Quick Start Guide

Instruction Manual. AP-SoftPrint. Multiwave 3000/ Multiwave ECO and Synthos 3000 Software v2.5

Transcription:

Page 1 of 12

Copyright The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation to this document. The software described in it can only be used if the customer is in possession of a general license agreement or single license. Using and copying is only allowed in concurrence with the specifications stipulated in the contract. Under no circumstances may any part of this document be copied, reproduced, transmitted, stored in a retrieval system, or translated into another language without the express written permission of ETAS GmbH. Copyright 2018 ETAS GmbH, Stuttgart The names and designations used in this document are trademarks or brands belonging to the respective owners. Page 2 of 12

Contents 1 Introduction... 4 1.1 Definitions and Abbreviations... 4 1.2 Conventions... 4 2 Product Definition... 5 2.1 Functions at a Glance... 5 2.2 General Description... 6 2.2.1 Safety Notice... 6 2.2.2 System Prerequisites... 6 2.2.4 Software Prerequisites... 7 2.2.5 Restrictions... 7 2.2.6 Miscellaneous... 7 2.3 Delivery... 7 2.3.1 Used 3rd Party Software... 7 2.4 Installation... 7 2.5 Licensing... 7 2.6 Open Source Software... 7 3 Changes... 8 3.1 What s New with... 8 3.2 Fixed Problems... 9 3.3 Known Issue Reports... 9 3.4 Known Issues... 9 3.4.1 Software related Items... 9 4 Hints... 10 5 Hotfix Information... 11 6 Contact, Support and Problem Reporting... 12 Page 3 of 12

1 Introduction 1.1 Definitions and Abbreviations Term/Abbreviation EHI HSP HW KIR PR SW Definition ETAS Help Desk International Hardware Service Pack Hardware Known Issue Report For severe Problem Reports which occur after a release, ETAS has introduced the Known Issue Report to inform affected customer immediately. The current Known Issues of former versions can be found on the ETAS website: http://www.etas.com/kir Problem Report Software 1.2 Conventions The following typographical conventions are used in this document: Choose File Open. Click OK. Press <ENTER>. The "Open File" dialog box is displayed. Select the file setup.exe A distribution is always a one-dimensional table of sample points. Menu commands are shown in boldface. Buttons are shown in boldface. Keyboard commands are shown in angled brackets. Names of program windows, dialog boxes, fields, etc. are shown in quotation marks. Text in drop-down lists on the screen, program code, as well as path- and file names are shown in the Courier font. General emphasis and new terms are set in italics. Page 4 of 12

2 Product Definition 2.1 Functions at a Glance INCA -FLOW is used for documentation and automation of recurring calibration processes. By modeling the calibration task in the form of a flowchart the calibration engineer is able to design a graphic image of the manual calibration task. INCA-FLOW enables the calibration engineer to focus on its key task of the modeling and implementation of a calibration methodology and not on the syntax of a programming language. The tool allows the calibration engineer without programming knowledge to implement an calibration process / methodology. INCA-FLOW provides a library of base methods which can be used by the calibration engineer by drag-and- drop to build his process step by step. The parameters of each base method are graphically interactive and intuitive to use. These so-called basic methods have the most diverse tasks : Reading and writing parameters Input and output methods Design methods (e.g. Polyfit ) optimization methods (e.g. simplex algorithm ) iteration methods Condition Queries ( bits variables) bypass methods (e.g. freely configurable controller ) stimuli generator (e.g. sine, square waves, APRBS ) cycle generator (e.g. FTP75 cycle) Interface to Matlab Mathematical / Statistical Methods ( formula editor, FFT, filtering, histogram, mean, Min- /Max-Bestimmung, standard deviation, etc. ) Visualization methods (measurement channels over time, histograms, visualization and production of maps and characteristics) The involvement of external measurement equipment such as thermal scanning, AD and lambda scan is guaranteed by the link to INCA. Project and Process Configuration Calibration processes can be modeled and exports and thus passed from one engineer to another engineer. The application programmer has the ability to create for recurring similar processes of several basic methods, so-called library methods. These are then automatically managed in a separate library and can as the base methods with drag and drop be installed in the flow chart. They can also be imported and exported. Calibration and measurement parameters are to be defined as the variables themselves own centrally managed in the database. Page 5 of 12

2.2 General Description 2.2.1 Safety Notice Calibration activities influence the behavior of the ECU and the systems controlled by the ECU. This may result in unexpected behavior of the vehicle and thus can lead to safety critical situations. Only well trained personnel should be allowed to perform calibration activities. Sending CAN messages influences the behavior of the CAN bus network and the systems connected to it. This may result in unexpected behavior of the vehicle and thus can lead to safety critical situations. Only well trained personnel should be allowed to perform CAN message sending activities. Calibrate measurement (Write to RAM) activities influence the behavior of the ECU and the systems controlled by the ECU. This may result in unexpected behavior of the vehicle and thus can lead to safety critical situations. Only well trained personnel should be allowed to perform calibrate measurements activities. 2.2.2 System Prerequisites Certain system requirements must be fulfilled to install and work with INCA-FLOW. The minimum system requirements for using INCA-FLOW are as follows: > 1600 MHz CPU > Operating systems: Microsoft WINDOWS 10 > 1 GB RAM > Hard disk with a minimum of 500 GB of free space > XGA graphics card with XGA monitor and a resolution of at least 1024 x 768 with 16 bit colors The recommended system requirements for using INCA-FLOW are as follows: > 2 GHz dual-core CPU > Operating systems: Microsoft WINDOWS 10 > 2 GB RAM > Hard disk with 1 GB of free space > CD-ROM drive for installation > SXGA graphics card with SXGA monitor and a resolution of at least 1280 x 1024 with 32 bit colors Page 6 of 12

2.2.4 Software Prerequisites To work with INCA-FLOW you need either one of the following software: INCA V7.1 INCA V7.2 VISION V4.0 2.2.5 Restrictions 2.2.6 Miscellaneous None 2.3 Delivery The software is delivered via download on the ETAS Download Page. 2.3.1 Used 3rd Party Software The 3rd Party Software used by INCA-FLOW is listed in the documentation in the folder \ OpenSourceSoftware. 2.4 Installation For details on installation or licensing see the separate installation instructions document. 2.5 Licensing INCA-FLOW is protected via electronic licensing. In order to run and use the products, a license file is required. The license needs to be installed via the ETAS License Manager. The license manager is opened during the installation and can also be started at a later point as an external program located in the ETAS program folder in the Start menu. The license file can be obtained through a self-service portal on the ETAS website by using the software entitlement you received during the order process or it is provided by your tool coordinator. 2.6 Open Source Software INCA-FLOW contains some open source components which are listed in the Open Source attribution document. This is found in the Documentation part of the CD under OpenSourceSoftware. Page 7 of 12

3 Changes This chapter describes changes with respect to the previous version of INCA-FLOW Add-on 3.1 What s New with New methods: Get software and dataset name TDT analysis Online TDT analysis Query the name of the software and dataset name of an INCA device Changes in methods: Shell execute New parameter Hide window Drivecycle WLTC cycle generation with gearshift calculation MDF read Possibility to use global reference names for signals Other: TDT - Support for MDF4 format - Search & sort mechanism for signals - Adding signal names from MDF file - More explanation and help - Improvement of display functions - Toolbars for 2D and 3D Diagrams Test-bench methods Not useable in standalone processes anymore EDT viewer Showing data point values as tool-tips Improvements Interpreter The start of the process was cancelled if hardware was not available INCA API Removed INCA licence check before connecting to COM API Standalone executable Deactivated methods were activated in standalone process Read file CDFX 2.1 was not supported SI states Fixed error when deleting states or duplicating process Variable management Remove unused elements removed elements used by Excel read/write Please refer to the what s new presentation for more details. Page 8 of 12

3.2 Fixed Problems This section describes the set of fixed problems of the previous versions of INCA-FLOW Addon. Calls fixed in 596279 The start of the process is cancelled if hardware initialization is not done 595645 unable to connect INCA because INCA not licensed 596049 INCA-FLOW crashes when deleting a process state 602539 Deactivated methods were executed in SI process 593796 Unable to read values from CDFX 2.1 file 597665 Duplicating a process leads to a loss of the parameters in the SI States 581909 Error from IncaFlow.Automation Visualization: Save Image block doesn't support user-defined variables 589202 (starting with $) as filename 597222 Input Window: UX inconsistent view between Developer and SI 603406 Method Python is not working with standalone executable 3.3 Known Issue Reports If a product issue develops, ETAS will prepare a Known Issue Report (KIR) and post it on the internet. The report includes information regarding the technical impact and status of the solution. Therefore you must check the KIR applicable to this ETAS product version and follow the relevant instructions prior to operation of the product. The Known Issue Report (KIR) can be found here: http://www.etas.com/kir 3.4 Known Issues This section describes the set of known problems of the released version of INCA-FLOW Add-on. 1. When INCA has a system crash, INCA-FLOW doesn t get updated of the system crash of INCA and hence doesn t switch to Reference page 3.4.1 Software related Items 603706 603020 INCA-FLOW EDT - Performance after Project Configuration Change / Download differences does not clear checksum INCA-FLOW TB Analysis: Control Performance Analysis Library "T_rise 10% 90% of Target value" parameter to be included in the outcome Page 9 of 12

4 Hints None Page 10 of 12

5 Hotfix Information None Page 11 of 12

6 Contact, Support and Problem Reporting For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: ETAS subsidiaries WWW: www.etas.com/en/contact.php ETAS technical support WWW: www.etas.com/en/hotlines.php Page 12 of 12