Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

Similar documents
Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Product information. Hydrostatic. Submersible pressure transmitter VEGABAR 86 VEGABAR 87 VEGAWELL 52. Document ID: 45079

Product information Ultrasonic

Safety instructions Overvoltage protection B81-35

Product information. Radar. Level measurement in bulk solids VEGAPULS 67 VEGAPULS SR 68 VEGAPULS 68 VEGAPULS 69. Document ID: 29427

Operating Instructions

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Product information. Guided Wave Radar. Level measurement in bulk solids VEGAFLEX 82 VEGAFLEX 86. Document ID: 46598

Operating Instructions VEGABAR 17. Process pressure transmitter with metallic measuring cell ma. Document ID: 27636

Safety instructions VEGATOR 121, 122

Indication and adjustment. LG Remote Interface Operating Instructions 06/2015

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Product information. Radar. Level measurement in liquids VEGAPULS WL 61 VEGAPULS 61 VEGAPULS 62 VEGAPULS 63 VEGAPULS 64 VEGAPULS 65 VEGAPULS 66

Operating Instructions VEGABAR 83. Pressure transmitter with metallic measuring cell. Profibus PA. Document ID: 45037

Operating Instructions VEGABAR 82. Pressure transmitter with ceramic measuring cell. Profibus PA. Document ID: 45031

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Operating Instruction

Signal conditioning instruments VEGASCAN 693. Product Information

Ø 11,4 21,5. M9 x 0,5 Ø 12 Ø 11,4. M9 x 0,5 Ø 12. M9 x 0,5

Product information. Radar. Level measurement in liquids VEGAPULS WL 61 VEGAPULS 61 VEGAPULS 62 VEGAPULS 63 VEGAPULS 64 VEGAPULS 65 VEGAPULS 66

VEGAMET 381 VEGAMET 624 VEGAMET 625

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Operating Instructions GWR TDR sensor for continuous level measurement of bulk solids ma/hart - two-wire Rod and cable probe

Safety Manual. VEGABAR series ma/hart - two-wire and slave sensors With SIL qualification. Document ID: 48369

Operating Instructions VEGACONNECT 4 with connection box Interface converter USB - HART/I²C

Operating Instructions. PACTware/DTM Collection 04/2018. Software for adjustment of communication-capable sensors and signal conditioning instruments

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic

Indication and adjustment

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Operating Instructions PLICSCOM. Display and adjustment module. Document ID: 36433

VEGA SOFTWARE AND DISPLAY INSTRUMENTS

Operating Instructions VEGAFLEX 81. TDR sensor for continuous level and interface measurement of liquids. Two-wire 4 20 ma/hart Rod and cable probe

Absolute Encoders Multiturn

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Operating Instructions PLICSCOM. Display and adjustment module. Document ID: 36433

Industrial Hydraulics FAQs

Safety Instructions Cerabar S PMP71, PMP75

BVS UR E Ordering code: BVS001H

Supplementary instructions. Mounting adapter PTB 9. For mounting on the existing mounting bracket (GM-17 ) Document ID: 55643

APS4 Inductive Proximity Sensors

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Operating Instructions PACTware/DTM Collection 07/2010 Installation, first steps

Operating Instructions VEGAFLEX 81. TDR sensor for continuous level and interface measurement of liquids

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

M8, M12, 3-, 4-, 5-, 8-, 12-pin, LED, shielded

Operating Instructions VEGAFLEX 81. TDR sensor for continuous level and interface measurement of liquids ma/hart - four-wire Coax probe

Operating Instructions VEGAFLEX 67

Operating Instructions VEGAFLEX 81. TDR sensor for continuous level and interface measurement of liquids

Operating Instructions GWR TDR sensor for continuous level measurement of bulk solids

WINSTA. Full Line Catalog 2008/2009

Device Configurator ECI-1

Basler Accessories. Technical Specification POWER-I/O-PLC+ CABLE, HRS 12P/OPEN, 10M. Order Numbers

Operating Instructions VEGAFLEX 61 Profibus PA

Basler Accessories. Technical Specification POWER-I/O CABLE HRS 6P/OPEN. Order Numbers

Magnetic Style Safety Interlock Switches

Digital electropneumatic positioner

Operating Instructions. PACTware/DTM Collection 05/2013. Installation, first steps. Document ID: 28243

Operating Instructions VEGAMET 381

Resistance thermometer With spring-loaded tip Model TR55

Operating Instructions VEGAFLEX 81. TDR sensor for continuous level and interface measurement of liquids

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Technical Data Photoelectric Sensors

Operating Instructions PACTware/DTM Collection 07/2012 Installation, first steps

Mating connectors and cable sets for valves and sensors in hydraulics

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

DRAFT. Basler Accessories. Technical Specification GP-I/O CABLE 6P/OPEN. Order Number

Absolute encoders multiturn

CATALOGUE CAPACITIVE SENSORS KXS

Float switch For industrial applications Model RLS-1000

07. har-link Interface Connectors

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

Level measurement Ultrasonic

Complete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter

Active Distributors AS-i Safety, Active Distributors AS-i

Operating Instructions FIBERTRAC 32. Radiation-based sensor for continuous level and interface measurement ma/hart - four-wire

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

07. har-link INTERFACE CONNECTORS

SW IP67 Waterproof Series - Part Numbering

PHOENIX CONTACT - 01/2008

Product Information. ECI 119 Absolute Rotary Encoder

PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Operating Instructions. VEGAPULS 66 standpipe version ma/hart - four-wire. Document ID: 28742

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Operating Instructions VEGASON 62. Ultrasonic sensor for continuous level measurement ma/hart - four-wire. Document ID: 28779

ST Series - Part Numbering

Quick setup guide VEGAPULS WL 61. Radar sensor for continuous level measurement of water and wastewater ma/hart two-wire. Document ID: 47095

TROVIS-VIEW software TROVIS 6661

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

07. har-link Interface Connectors

Gas-actuated thermometer Stainless steel version Model 73

Accessory Kit for all Designs of Hand-held Pendant Station

Transcription:

Supplementary instructions VEGADIS adapter For connection of an external display and adjustment unit or a slave sensor Document ID: 45250

Contents Contents 1 For your safety 1.1 Appropriate use... 3 1.2 General safety instructions... 3 1.3 Safety instructions for Ex areas... 3 2 Product description 2.1 Configuration... 4 2.2 Principle of operation... 4 3 Mounting 3.1 Mounting preparations... 6 3.2 Installation procedure... 6 4 Connection 4.1 Overview... 8 4.2 External display and adjustment unit... 9 4.3 Slave sensor... 10 5 Supplement 5.1 Technical data... 11 5.2 Dimensions... 12 2 Editing status: 2016-08-10

1 For your safety 1 For your safety 1.1 Appropriate use The VEGADIS-Adapter is an accessory part for connection of an external display and adjustment unit or a slave sensor to an existing plics sensor with double chamber housing. 1.2 General safety instructions The safety information in the operating instructions manual of the respective sensor must be noted. 1.3 Safety instructions for Ex areas Take note of the Ex specific safety instructions for Ex applications. These instructions are attached as documents to the respective sensor with Ex approval and are part of its operating instructions manual. 3

2 Product description 2 Product description Scope of delivery Versions 2.1 Configuration The scope of delivery encompasses: VEGADIS-Adapter Ready-made connection cable (optional) Documentation This operating instructions manual The VEGADIS-Adapter consists of a contact plate, a connection cable with mini plug connector and an M12 x 1 plug. It is available in two different versions for 4 20 ma/hart as well as PA/FF sensors. The optional, ready-made connection cable is available in different plug and colour versions as well as lengths. 1 2 3 4 Fig. 1: Configuration VEGADIS-Adapter 1 Contact plate 2 Mini plug connector 3 Connection cable 4 M12 x 1 plug Function 4 2.2 Principle of operation The VEGADIS-Adapter is used for connection of an external display and adjustment unit VEGADIS 61 or VEGADIS 81to the following plics sensors with double chamber housing: VEGAPULS series 60, hardware from 2.0.0, software from 4.0.0 VEGAPULS 64, 69 VEGAFLEX 80 series VEGABAR series 80 The VEGADIS-Adapter enables also the connection of a slave sensor to a VEGABAR series 80 sensor with double chamber housing and additional current output. Information: For operation of the slave sensor, the version of the master sensor with double chamber housing and additional current output is absolutely necessary.

2 Product description It uses the contact pins of the electronics module for the display and adjustment module PLICSCOM. Thus it is possible to connect external instruments to the sensor, even if the terminals of the electronics module are already occupied by the connection cables to the second housing chamber. Installation The contact plate is inserted into the electronics compartment of the double chamber housing. The M12 x 1 plug is screwed into the housing wall instead of the blind plug. Note: The housing cover without inspection window still fits on the electronics compartment when the adapter is mounted in place. Parallel use of the PLICSCOM display and adjustment module in the sensor and in the external display and adjustment unit VEGADIS 61 or VEGADIS 81 is permitted. However, simultaneous adjustment of the sensor is not possible. 5

3 Mounting 3 Mounting Tools Installation 3.1 Mounting preparations The following tools are required for mounting: Spanner SW 19 or hexagon socket key size 8 for unscrewing the blind plug Spanner SW 17 for screwing in the M12 x 1 plug 3.2 Installation procedure Proceed as follows to mount the adapter: 1. Open the cover of the electronics compartment 1 2 Fig. 2: Position of the electronics compartment and the blind plug on the double chamber housing 1 Electronics compartment 2 Blind plug 2. Unscrew the blind plug on the side of the electronics compartment 3. Loosen the mini plug connector on the adapter 4. Insert the plug through the free opening and screw the M12 x 1 plug connector into the housing 5. Connect mini plug connection to the adapter 6. Place adapter on the electronics (1) and turn it to the right (2), see following illustration: 1 2 6 Fig. 3: Attach the adapter

3 Mounting The mounting of the adapter is finished. 7

4 Connection 4 Connection Electronics compartment 4.1 Overview 1 2 3 Fig. 4: View to the electronics compartment with mounted adapter 1 Adapter plics plus 2 Internal cable connection 3 Plug connector M12 x 1 Wiring plan - 4 20 ma/ HART sensors 1 4 Fig. 5: Top view of the plug connector 2 3 Contact pin Colour, connection cable Terminal, external display and adjustment unit or Slave sensor 1 Brown Terminal 5 2 White Terminal 6 3 Blue Terminal 7 4 Black Terminal 8 Wiring plan - PA/FF sensors 1 4 2 3 8 Fig. 6: Top view of the plug connector

4 Connection Contact pin Colour, connection cable Terminal, external display and adjustment unit or Slave sensor 1 Brown Terminal 5 2 White Terminal 6 3 Blue Terminal 7 4 Black Terminal 8 5 Yellow/green Connection example 4.2 External display and adjustment unit 3 6 1 4 5 Display 2 Fig. 8: Connection example for VEGADIS-Adapter with external display and adjustment unit 1 Signal cable 2 Sensor 3 VEGADIS-Adapter 4 Plug connector M12 x 1 5 Ready-made connection cable (optional) 6 External display and adjustment unit 9

4 Connection Connection example 4.3 Slave sensor 3 6 1 4 5 Connect to Master 2 Fig. 9: Connection example for VEGADIS-Adapter with slave sensor 1 Signal cable 2 Sensor 3 VEGADIS-Adapter 4 Plug connector M12 x 1 5 Ready-made connection cable (optional) 6 Slave sensor 10

5 Supplement 5 Supplement 5.1 Technical data Materials Contact plate M12 x 1 plug Seal Plastic (PBT) 316L FKM Interface to the external display and adjustment unit, slave sensor Data transmission Digital (I²C-Bus) Connection cable Four-wire Sensor version 4 20 ma, 4 20 ma/hart Profibus PA, Foundation Fieldbus Configuration, connection cable Cable length Standard cable Special cable Screened 50 m 1) 25 m Electromechanical data - Connection cable for 4 20 ma/hart sensors Configuration Four cores, insulation, cable jacket Material PVC, PUR Wire cross-section 0.34 mm² (AWG 22) Length max. 50 m (84.04 ft) Min. bending radius at 25 C/77 F 25 mm (0.985 in) Diameter approx. 5 mm (0.315 in) Electromechanical data - Special cable for PA/FF sensors Configuration three cores, inner screen as fourth core, insulation, outer screen, jacket Material PUR Wire cross-section 0.34 mm² (AWG 22) Length max. 25 m (82.021 ft) Min. bending radius at 25 C/77 F 25 mm (0.985 in) Diameter approx. 8 mm (0.197 in) Protection rating Sensor with connected cable ƲƲ Pressure transmitter IP 66/IP 67 ƲƲ Other sensors IP 66/IP 68 (0.2 bar) 1) Slave sensor 25 m 11

5 Supplement 5.2 Dimensions ø 62,5 mm (2.46") 8,9 mm (0.35") 43,5 mm (1.71") M 16x1,5 11 mm (0.43") 7,5 mm (0.30") 87,5 mm (3.45") M 12x1 Fig. 10: Dimensions VEGADIS-Adapter 12

Notes 13

Notes 14

Notes 15

Printing date: All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice VEGA Grieshaber KG, Schiltach/Germany 2016 VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com