Motor Control Simulation

Similar documents
Universal Display Simulation

Control Panels, Distribution Panels and Components

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

Standard Instructions Special Instructions High-Speed Instructions SIMATIC S7-200 Programmable Controller System Manual

SMART RELAY SRW 01 V4.0X

Experiment #2 PLC Input Output Wiring Methods. OBJECTIVES After successfully completing this laboratory, you should be able to:

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011

Fundamentals of circuits with contacts

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

onlinecomponents.com

An OR Operation. Or (O) Function I0.4 Q0.1 I0.5 I0.5 I0.4 Q0.1. Input 3. Input 4. Output 2

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

PLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL

Large Frame IEC Contactors

InstrumentationTools.com

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

1. Introduction ALSPA MV DELTA

0 1 CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA-20 27

Safe shutdown of SIRIUS 3RA6 compact starters with IO-Link interface. SIRIUS Industrial Controls, Safety Integrated, IO-Link FAQ 05.

Exercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION

IQM & IQML RANGE CONTROL AND MONITORING FACILITIES. Publication E420E issue 7/02

PLC Fundamentals. Module 3: Programming with Function Blocks. Academic Services Unit PREPARED BY. January 2013

Pretest Programmable Logic Controllers. Unit 1, Task 1

EandT Touchscreen Driver helpviewer

Module 4. Programmable Logic Control Systems. Version 2 EE IIT, Kharagpur 1

Nanotec Electronic GmbH Gewerbestrasse Landsham near Munich Tel: 089/ Fax: 089/

3RT, 3TB, 3TF Contactors for Switching Motors

Contactors and Contactor Assemblies

Applikationen & Tools. Safe switching of IO-Link motor starter combination 3RA27 with safety relay 3SK1. IO-Link. FAQ November 2012

pointofsale available at your local trade outlet

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

SANKALCHAND PATEL COLLEGE OF ENGINEERING, VISNAGAR. ELECTRONICS & COMMUNICATION DEPARTMENT Question Bank- 1

ELECTRICAL CONTROL SYSTEM COMPONENTS

Conveyor Station Exercise 1: Learning about components and their function

DEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual

PLC Programming. Ladder Diagrams

Contactors and Contactor Assemblies

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

2. Acquired the know how about the principle of automation. 3. The capability to understand the PLC based systems and machinery.

OPERATING PANELS. PROGRAMMING Manual EBELT OPERATING PANELS

ELR W1/ 6-24DC. Extract from the online catalog. Order No.:

SENTRON ATC Automatic Transfer Control Device

Revolutionizing control wiring

MFS605/EE605 Systems for Factory Information and Control

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Table of Contents 1. Overview Installation...6

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

NPA Pendant Control Station

PLC Fundamentals. Module 1: Introduction to PLC. Academic Services Unit PREPARED BY. August 2011

PLC Exam 6/18/2014 Name: I. Matching. Match the System memory Data Files to their descriptions.

5000 Series Audio Matrix

Project Planning. Module 4: Practice Exercises. Academic Services Unit PREPARED BY. August 2012

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters

- Electronic Limit Switches - Very Accurate - Easy to use - Robust - Dependable - High Resolution - Non Contact Measurement - Wide Temp.

Section 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents

IEC Power Control Contactors and Contactor Assemblies

Rotator and Controller by Spid. User Manual

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.

Ryan Everaert Application Note Team - I Application Note for Toshiba Bipolar Stepper, Part Number TB6560AHQ

PLC Fundamentals. Module 3: Programming with Function Blocks. Academic Services Unit PREPARED BY. August 2011

Product RS stock no. Mitsubishi no. Description and features Display FX-40DU-E LCD display and function keys directly connected into FX PLC

Course 1 of the Beginners' Course is designed to help you become acquainted with the new user interface of the easysoft programming software.

Allen-Bradley Bulletin 100 Contactors

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

With a digital input we can read two states, a high or low. A switch can be open or closed.

Contactors and Contactor Assemblies

Device manual AS-i PowerSwitch ZB0028 ZB0040

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

Remote units Hands free or telephone handset options available. Master to remote and remote to master calling

Crane Control Class 9004

PLC Fundamentals. Module 1: Introduction to PLC. Academic Services Unit PREPARED BY. January 2013

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

SYMETRIX SOLUTIONS: TECH TIP May 2014

DCN Synoptic Microphone Control. Software User Manual en LBB 3571

A 3-SPEED STEPPER MOTOR

Compressor Controller MAM 890

Getting Started Tutorial

Alarm Distribution Shelf (ADS)

the absence of a signal. produce a result at one or more of their outputs. parallel. Y= AB. interconnected. connected. changed.

FANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook

Courseware Sample F0

N2S and N2SC Series Control Stations

For Immediate Delivery call KMParts.com at (866)

Ocean Controls KTA-224 Modbus IO Module

Motor Control Products Selection Guide

MODULE TITLE : PROGRAMMABLE LOGIC CONTROLLERS TOPIC TITLE : LADDER DIAGRAM PROGRAMMING AND STRUCTURE OF THE PLC TUTOR MARKED ASSIGNMENT 2

PROGRAMMING AND CUSTOMIZING

Certificate of Compliance

C E R T I F I C A T E O F C O M P L I A N C E

1. Introduction. 2. Design. Safety and Emergency Stop Circuit Design Standard. Safety and Emergency Stop Circuit Design Standard.

SECTION 1 Introduction

Note 1: Throughout this manual the Modbus Module Mk2 may simply be referred to as the module.


Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

BRC SERIES 20kW High Voltage Power Supply

EU Declaration of Conformity

Transcription:

Motor Control Simulation 1

1 Simulation operating modes Immediately after the program has been started, the main menu appears on the screen. The mouse pointer is visible in the form of a hand. The operating modes can be selected from the menu bar at the top of the screen by means of the left mouse button. Alternatively, the operating modes can be selected by pressing the corresponding hotkeys on the keyboard. These keys are shown underlined. The main circuit is visible in the upper half of the screen. The line width can be altered using the OPTIONS in the menu bar. The motor with a digital speed display is shown in the lower half of the screen. Additional audio motor noise can be switched on by selecting Sound on in the menu OPTIONS. 1.1 DEMO mode The current motor circuit is displayed in the menu bar at the top of the screen. Motor control is automatic in DEMO mode. This simulation shows possible practice examples for realizing an external control facility. The automatic process here shall be dealt with in exercises in the next chapter and will be replaced by a real control unit. None of the control elements can be activated in DEMO mode. The process can only be observed. Move the mouse pointer to the DEMO option button and briefly click the left mouse button. The mouse pointer moves immediately and simulates the steps for starting the motor circuit. The DEMO mode can be aborted by pressing any key or the left mouse button. 1.2 MANUAL mode All functions of the current motor circuit can be tested in the MANUAL mode, without a control unit connected. All actuators and operating elements are activated with a mouse click, and the response is observed. The status of the operating elements is displayed by LED's. At the same time, it is transmitted to the PC adapter, where real measurements can be performed. The main menu of the program is shown in the bar at the top of the screen. Move the mouse pointer to the OPTIONS button and briefly press the left mouse button. A list of options which can be set now appears in a window. Check whether the parallel interface to which your PC adapter is connected is displayed. If required, you can change the entry using the mouse. Also check whether the Lettering on option is active, so that consistent conditions apply for the following description. 2

Click on the MANUAL button in the menu bar at the top. The program is now in the manual mode. 10 switches now appear on the left-hand edge of the screen and 10 LEDs appear on the right. The simulation has a total of 10 switches or inputs. The motor contactors and signal lamps are labeled with K and H respectively. The corresponding actuator is activated by clicking on a switch with the mouse. The switches can also be actuated using the PC keyboard. To actuate a switch, press Shift together with the corresponding number, e.g. [0] for switch KO. In this example the contactor KO was triggered. Only the contactors which are visible on the screen can be operated. The system is operated by the buttons SO to S4. They can also be actuated by clicking the mouse button or by pressing the corresponding number key on the keyboard. However, they function as switches when the keyboard is operated. Their status is displayed by the LEDs on the right side of the screen. The off-button SO functions as an NC contact and supplies a 1-signal when inactive. Buttons Sl to S4 function as NO contacts. These four operator buttons also have NC contacts, S5 to S8. The fuse also has a NC contact, S9. The status of the LED's can be measured directly from the appropriate outputs of the PC adapter. The numbers of the switches coincide with the numbers of the terminals on the PC adapter. The numbers of the switches on the left side of the screen also coincide with the numbers of the inputs of the PC adapter, with which the system in the next chapter is externally controlled. In the MANUAL operating mode, you can test the switching sequences within the current motor circuit. 1.3 EXTERNAL mode The EXTERNAL mode is similar to the MANUAL mode in terms of screen configuration and operation. However, the actuators are no longer activated via switches but via the inputs of the PC adapter. The operating states of the inputs are indicated by LED's. Check whether the correct parallel interface has been selected in the OPTIONS menu. To activate an actuator, a 1-signal (24 V for PLC and 5 V for TTL mode) has to be applied to the corresponding PC adapter input. For example, if input 7 of the PC adapter is supplied with a 1-signal, the LED H7 lights up. 2 Motor Circuits In the option menu one of the seven motor circuits can be selected. The current circuit is shown at the top of the screen. 3

In the following chapters the controls for various circuits are to be developed. The logic diagram has been selected as the representational form, because it is the easiest to apply to the various types of control. There is a demonstration mode DEMO provided for each circuit to present the various exercises. In the MANUAL operating mode the circuit can be dealt with in detail. After developing the control program (logic diagram) the real control system is set up. If a control system is to be assembled out of simulog plug-in elements, these can be taken 1:1 from the logic diagram. When a PLC is used as a control unit then the logic diagram is programmed into the PLC memory either directly or as a statement list. A master copy for the drafting of assignment lists for the respective inputs and outputs can be found on page 19. In chapter 4, Control Examples, you will find additional tips for putting other kinds of controls into operation. 2.1 Self-holding The circuit with a storage function in a contactor control operation is called the self-holding circuit. An NO contact of the contactor is connected parallel to the onbutton as a self-holding contact. An NC contact is used as the off-button, which interrupts the holding current circuit when activated and thus cancels the selfholding action. Two different control circuits for a self-holding function are shown below. What is the difference between the two circuits? 4

The two circuit diagrams should not be converted into function diagrams. Since the S0 is designed as an NC contact, it must be polled for 1-signals. Correctly complete the function diagram on the right. Now the PLC has to be programmed, i.e. the discrete control has to be assembled and tested. Notes on putting the various controls into operation can be found in Chapter 4. Further possibilities: Naturally an RS storage element can also be programmed to perform a self-holding function. In order for the PLC to process all commands one after the other, the last command processed has priority. In the case of reset priority, the reset switching condition of the RC storage element has to be programmed last. 5

2.2 Reversing Circuit We start with the main circuit and the circuit diagram for a reversing control circuit without direct switchover. This means switch-off has to be performed before switchover. The pushbuttons and the contactors arc interlocked (latching). For pushbutton latching there arc two different possibilities: 1. Only the NO contacts of the pushbutton are connected to the PLC. If the NC contact of the pushbutton is needed within the program, then the signal is simply programmed to negate when polled (i.e. it is negated by the programming language). 6

2. All NC and NO contactors of the pushbuttons are connected to the inputs of the PLC and programmed as 1-signal generators without negation in accordance with the circuit diagram. Both possibilities are standard procedures in practice. However, the second possibility provides greater reliability, because when the pushbutton is activated the NC contact always opens first because of the leading make action, before the NO contact closes and thus the latching command (see circuit diagram) is always issued before the switch-on command. The contactor latching also has to be set up in the reversing control circuit. In the PLC program (function diagram) this is performed by negative polling of the mutual outputs, which act as 0- signal generators because they have not been set. Naturally, outside the PLC even more contactor latching has to be carried out in actual operations using their auxiliary contacts. Complete the following function diagram. But here you have to assume that the pushbutton SO is only available via an NC contact and that pushbuttons Sl and S2 are only available via NO contacts. Now the PLC has to be programmed, i.e. the discrete control circuit must be set up and tested. Notes on putting the various controls into operation can be found in Chapter 4. Further possibilities: Naturally, instead of polling NO contacts Sl and S2 with negation, you can also poll the corresponding pushbutton NC contacts S4 and S5 directly. Which modifications have to be carried out in the logic diagram, in order to permit a direct reversal of the rotation direction? 7

2.3 Dahlander Circuit Switching condition for a Dahlander motor When the mains is connected to terminals 1U, IV and 1W the motor rotates at low speed. By connecting the mains to terminals 2U, 2V and 2W and connecting terminals 1U, IV and 1W with a star bridge the motor runs at high speed. A Dahlender circuit operating in clockwise rotation is produced according to the switching conditions provided above for the main circuit. Slow speed: Contactor K3 Fast speed: Contactors K2 and K4 Switching conditions for the control circuit Control of a Dahlander circuit must always be designed so that during switchover the respective switching stage has been completed and released before the next switching stage can be switched on. This fixed sequence is necessary to prevent switching overlaps from arising between low and high speed in the main circuit. Switching overlaps between the main contactors at low speed and the star contactor at high speed would lead to a short-circuit in the main circuit. The control circuit depicted also has the following function: The higher speed can only be switched on via the low speed. Direct switchover between the two speeds is not permitted. 8

Complete the following function diagram and make an assignment list for your PLC. The indicator lamps H8 and H9 should be triggered parallel to contactors K3 and K4. The auxiliary contactor KH is realized within the PLC control program using a marker. 9

2.4 Reversing Dahlander Circuit The main circuit of a reversing Dahlander circuit is depicted with the following contactor functions: K0 = Reversing contactor - clockwise K1 = Reversing contactor - counterclockwise K2 = Mains contactor for high speed K3 = Mains contactor for low speed K4 = Star contactor for high speed Control circuit diagram 10

After determining the rotation direction, the low or the high speed is switched on each time from 0. Switchover from a low initial speed setting to the high speed should be possible, but switching the setting back from the high to the low speed should not. Reversal of rotation direction and switch back to low speed are only possible if the motor has been switched off first. Complete the function diagram and draw up an assignment list for using the PLC as a control unit. 11

Here there is also the alternative of polling the NC contacts S5 to S8 for the latching of the pushbuttons. 2.5 Star-delta Circuit Main circuit: The motor starts in clockwise rotation direction in the star circuit configuration, if the star contactor K4 and the mains contactor K2 are activated. In delta connection the motor runs, if the delta contactor K3 and the mains contactor K2 are activated. During switchover the star contactor has to deactivate first and then the delta contactor. What happens ifk3 and K4 are deactivated simultaneously? 12

All of the controls for star-delta circuits must fundamentally be designed so that during switchover from star to delta, the star contactor must deactivate first, before the delta contactor may be activated. Otherwise switching overlaps cause shortcircuits in the main circuit. Pushbutton Sl activates the star contactor K4. K4 then activates the mains contactor K2. K4 and K2 are self-holding. The delta contactor K3 is latched by an NC contact of the star contactor K4. By actuating pushbutton S2 the star contactor K4 releases. This cancels the latching of the delta contactor K3 and K3 activates. Switch off is performed using pushbutton S0. Complete the function diagram and draw up an assignment list for using the PLC as a control unit. Further possibilities: Develop an automatic switchover operation by including a time function from the existing circuit diagram. Pushbutton S2 is omitted and replaced by a timer. 2.6 Reversing Star-Delta Circuit The main circuit of a reversing star-delta circuit is depicted with the following contactor functions: K0 = Mains contactor - clockwise rotation Kl = Mains contactor - counterclockwise rotation K3 = Delta contactor K4 = Star contactor 13

Control circuit: The mains contactor K0 is activated for clockwise rotation of the motor by actuating pushbutton S1. K0 is self-holding. For counterclockwise rotation the mains contactor K1 is activated by pressing pushbutton S2. K1 is self-holding. Both contactors are interlocked, i.e. pushbutton and contactor are latched. The mains contactor K0 or the mains contactor K1 activates the star contactor K4 and operates the time relay KT. With a changeover contact KT deactivates the star contactor with time delay and then activates the delta contactor K3. K3 is selfholding and deactivates the time relay. The star contactor K4 and delta contactor 14

K3 are interlocked. The clockwise rotation direction is signaled by the light indicator H9 and counterclockwise rotation is signaled by the light indicator H8. Complete the function diagram and draw up an assignment list for using the PLC as a control unit. 15

2.7 Slip-ring rotor with step starter When the motor is switched on with mains contactor K2 the motor starts with all the step resistors in the rotor circuit connected. During run up the step resistors are short-circuited to the rotor one after the other with a time delay of 1s. 16

Control circuit: Complete the function diagram and draw up an assignment list for using the PLC as a control unit. 17

18

Assignment list for the inputs and outputs System input Active for Control output Description K0 1 Mains contactor K1 1 Mains contactor K2 1 Mains contactor K3 1 Mains contactor K4 1 Star contactor K5 1 Step contactor K6 1 Step contactor H7 1 Light indicator red H8 1 Light indicator yellow H9 1 Light indicator green Commentary System Contact Control in Description Commentary output NO/NC SO NC Pushbutton 0 Sl NO Pushbutton I S2 NO Pushbutton II S3 NO Pushbutton III S4 NO Pushbutton IV S5 NC Pushbutton I S6 NC Pushbutton II S7 NC Pushbutton III S8 NC Pushbutton IV S9 NC Fuse Marker/ Active for Control Description Commentary Timer 1/0 KH 1 Auxiliary contactor KT 1 Timer NO == Normally Open supplies a 1-signal when activated NC = Normally Closed supplies a 0-signal when activated 19