C a t p h a n / T h e P h a n t o m L a b o r a t o r y

Similar documents
C a t p h a n 500 and 600 M a n u a l

C a t p h a n 700 M a n u a l

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

C a t p h a n 604 M a n u a l

Lucy Phantom MR Grid Evaluation

S. Guru Prasad, Ph.D., DABR

Image Acquisition Systems

Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Introduction to Positron Emission Tomography

Ch. 4 Physical Principles of CT

Introduction to Biomedical Imaging

A study on image quality provided by a kilovoltage cone-beam computed tomography

Quality control phantoms and protocol for a tomography system

BME I5000: Biomedical Imaging

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

UNCOMPROMISING QUALITY

Design and development of a phantom for tomosynthesis with potential for automated analysis via the cloud

ISO ISO ISO OHSAS ISO

Loma Linda University Medical Center Dept. of Radiation Medicine

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Basics of treatment planning II

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Micro-CT Methodology Hasan Alsaid, PhD

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Evaluation of AutoQA Lite TM Image Quality Measurement Software

Spectral analysis of non-stationary CT noise

MEDICAL IMAGING 2nd Part Computed Tomography

MEDICAL IMAGING 2nd Part Computed Tomography

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

INTERNATIONAL STANDARD

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Basic Radiation Oncology Physics

Fits you like no other

Background. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE /

1. Deployment of a framework for drawing a correspondence between simple figure of merits (FOM) and quantitative imaging performance in CT.

COMPREHENSIVE QUALITY CONTROL OF NMR TOMOGRAPHY USING 3D PRINTED PHANTOM

CALIBRATIONS FOR ANALYZING INDUSTRIAL SAMPLES ON MEDICAL CT SCANNERS

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

INTERNATIONAL STANDARD

Fits you like no other

RADIOMICS: potential role in the clinics and challenges

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

DUE to beam polychromacity in CT and the energy dependence

Multi-Purpose Body Phantom

Modifications for P551 Fall 2014

Digital Image Processing

Medical Imaging BMEN Spring 2016

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste

USING cone-beam geometry with pinhole collimation,

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

ph fax Deming Way Middleton WI USA

Patient Set-ups and Tumor Localizations

TESTING OF THE CIRCLE AND LINE ALGORITHM IN THE SETTING OF MICRO-CT

AAPM Standard of Practice: CT Protocol Review Physicist

RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package.

If it matters to you, it matters to us

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Corso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

Performance Evaluation of the Philips Gemini PET/CT System

Automated Quality Assurance for Image-Guided Radiation Therapy

James R Halama, PhD Loyola University Medical Center

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

Feldkamp-type image reconstruction from equiangular data

Scatter Correction Methods in Dimensional CT

Quick Reference Datasheet For All RIT113 Packages

Financial disclosure. Onboard imaging modality for IGRT

The theory and practical aspects of proton imaging proton radiography (prad) and proton tomography (pct)

[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

ACMP 25th Annual Meeting

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program

LAB DEMONSTRATION COMPUTED TOMOGRAPHY USING DESKCAT Lab Manual: 0

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

Tomographic Reconstruction

Continuation Format Page

Digital phantoms for the evaluation of a software used for an automatic analysis of the Winston-Lutz test in image guided radiation therapy

Centralite CT Moving Laser Patient Positioning System (MRR-1)

7/13/2015 EVALUATION OF NONLINEAR RECONSTRUCTION METHODS. Outline. This is a decades-old challenge

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

DAILY LINAC QA BEAM QA

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Computational Algorithm for Estimating the Gradient Isocenter of an MRI Scanner

Assessment of OSEM & FBP Reconstruction Techniques in Single Photon Emission Computed Tomography Using SPECT Phantom as Applied on Bone Scintigraphy

PC/QCT Bone Mineral Density Software Model

Transcription:

C a t p h a n 5 0 0 / 6 0 0 T h e P h a n t o m L a b o r a t o r y

C a t p h a n 5 0 0 / 6 0 0 Internationally recognized for measuring the maximum obtainable performance of axial, spiral and multi-slice CT scanners. Extensive Research T h e P h a n t o m L a b o r a t o r y and physicist David Goodenough, Ph.D., have worked together to develop the Catphan Phantoms. (Dr. Goodenough has been involved in CT performance testing since the first generation EMI Scanner.) The new Catphan designs are based on over 25 years of scientific research and direct field experience in the evaluation of medical imaging equipment. > >

Convenient Set-Up The Catphan Phantom s patented design includes many exclusive features that make it easy to achieve perpendicular alignment. As all of the test sections are arranged at prescribed intervals from the first module, operators can quickly scan all test sections in a single sequence, eliminating the need to reposition the phantom for each section. In addition, the integral case mount allows the phantom to be positioned in the scanner, supported off the end of the table, eliminating table artifacts. The case is also equipped with a level to aid in positioning. Fast, easy positioning and the universal mount of the Catphan Phantom makes it ideal for daily quality assurance programs on any scanner. Solid-Cast Construction Catphan Phantoms are constructed from modules that fit snugly into a durable 20cm housing. Both the 500 and 600 Catphan models are made from solid-cast materials, eliminating material absorption of water and leaks associated with water bath phantoms, as well as problems related to varied water sources. Modular Design The Catphan modular design allows test modules to be interchanged. As your testing needs change and new modules are developed, you can upgrade test modules that are compatible with your Catphan system. Additionally, the modular design makes the Catphan system ideal for traveling physicists and engineers who conduct comprehensive evaluations of CT scanners at multiple locations, as they are easily transportable and no draining is required between uses. This brochure deals with two primary Catphan models: the Catphan 500 fifth generation model designed to address specific concerns associated with spiral CT scanners and the Catphan 600 sixth generation model designed to evaluate the Fast, easy positioning and the universal mount of the Catphan Phantom makes it ideal for daily quality assurance programs on any scanner. maximum performance potential of multi-slice CT Scanners.

Catphan 500 Designed to evaluate the maximum performance potential of axial and spiral CT scanners. Catphan 600 Designed to evaluate the maximum performance potential of multi-slice CT scanners with enhanced sensitometry samples for radiation therapy planning. CTP401 CTP528 CTP515 CTP486 CTP404 CTP591 CTP528 CTP515 CTP486 Test Module 500 600 CTP401 module with slice width, pixel size and sensitometry (Teflon, Acrylic, LDPE, Air) CTP404 module with slice width, pixel size and sensitometry (Teflon, Delrin Acrylic, Polystyrene, H 2 0, LDPE, PMP, Air) CTP515 low contrast module with supra-slice and subslice contrast targets CTP486 image uniformity module CTP591 module with slice geometry and point source bead module * ** Tests - Summary Scan slice geometry (slice width and slice sensitivity profile)* high resolution (1 to 21 line pairs per cm) phantom position verification patient alignment system check low contrast sensitivity comparative subslice and supra-slice low contrast sensitivity spatial uniformity scan incrementation noise (precision) of CT systems circular symmetry sensitometry (linearity)** pixel (matrix) size point spread function and modulation transfer function (MTF) for the x, y, and z axes* * The CTP591 module contained in the Catphan 600 described in this brochure enables these test measurements to be conducted in multiple slices covering a range of detector positions from a singlescan sequence. This eliminates the need to reposition the table and repeat scans to cover the z axis range of the multi-slice detectors. * * The CTP404 module contained in the Catphan 600 includes 3 additional sensitometry targets along with a small vial for a water sample. See the description for the CTP404 for more details.

CTP401/404 Slice Geometry and Sensitometry Module Diameter: 15cm Thickness: 25mm scan slice geometry (slice width) circular symmetry phantom position verification sensitometry (CT number linearity) patient alignment system check pixel (matrix) size scan incrementation Unique Advantages We use a 23 ramp angle instead of the 45 angle commonly used in phantoms to produce a ramp image 2.4 times longer, greatly reducing the effects of imprecise image measurements. Additionally, we use thin wire ramps to reduce the over-range streaking artifacts found in the more commonly used thick ramps, particularly in thin slice geometry (1mm or 2mm slice widths). The two opposing pairs of ramps allow operators to easily verify whether the phantom is correctly aligned with the scanner axis. By measuring the ratio between opposed ramps, gantry angles up to 10 can be verified, avoiding erroneous measurements. The CTP401 test module in the Catphan 500 includes sensitometry samples for Teflon, Acrylic, LDPE and Air. The CTP404 test module used in the Catphan 600 includes sensitometry samples for Teflon, Delrin, Acrylic, Polystryene, LDPE, PMP, Air and a small vial for water. Pixel size can be calculated by counting the number of pixels between the test cylinders in the x and y directions. The module also contains five acrylic spheres to evaluate the scanner s imaging of subslice spherical volumes. The diameters of the acrylic spheres are 2mm, 4mm, 6mm, 8mm, and 10mm. Two sets of opposing wire ramps aligned with the x and y axes are cast into the CTP401/404 module. These ramps are used to measure scan slice geometry, verify phantom position and check the patient alignment system and the scanner table incrementation.

CTP528 High Resolution Module Diameter: 15cm Thickness: 40mm scan slice geometry (slice width and slice sensitivity profile) high resolution (1 to 21 line pairs per cm) point spread function and modulation transfer function (MTF) for the x, y, and z axes Unique Advantages The unique design of the CTP528 minimizes visual artifacts by reducing the amount of high contrast material. The 2mm thick aluminum contrast figures are cast into position on the radial gauge, which has resolution sections ranging from 1 to 21 lines pairs per cm. This radial design pattern eliminates the possibility of streaking artifacts from other test objects. This section, combined with spherical beads rather than wire for MTF measurements, allows operators to avoid the tedious and time-consuming step of positioning and aligning MTF wires with the z axis. The point source beads also eliminate the over-ranging problems and streaking artifacts that occur with MTF wires, because the bead density is volume averaged with the surrounding material.

CTP515 Low Contrast Module Diameter: 15cm Thickness: 40mm low contrast sensitivity comparative subslice and supra-slice low contrast sensitivity Unique Advantages The CTP515 consists of a series of cylindrical rods of various diameters and three contrast levels to measure low contrast performance. The 40mm-long rods provide consistent contrast values at all z-axis positions, thereby avoiding any volume-averaging errors as you scan through the section. The unique subslice test objects enable evaluation of the effectiveness of different scan protocols (pitch, slice width and reconstruction algorhythms) in resolving subslice low contrast objects. For selection of helical and multi-slice image protocols, unique subslice low contrast targets (truncated cylinders) have been included in this module. Comparing the images obtained by scanning the subslice targets with different imaging settings (slice width, pitch and reconstruction algorithms) provides valuable information to assist with the selection of optimal protocols for identifying small low contrast objects such as tumors. Contrast Length Diameters Supra-slice contrast rods 0.3% 40mm 2, 3, 4, 5, 6, 7, 8, 9, 15mm 0.5% 40mm 2, 3, 4, 5, 6, 7, 8, 9, 15mm 1.0% 40mm 2, 3, 4, 5, 6, 7, 8, 9, 15mm Sub-slice contrast rods 1.0% 7mm 3, 5, 7, 9mm 1.0% 5mm 3, 5, 7, 9mm 1.0% 3mm 3, 5, 7, 9mm All of the various samples and the background material have equivalent effective atomic numbers; only the density is varied to produce changes in the effective attenuation coefficients. Subslice targets have a nominal 1.0% contrast and z-axis lengths of 3, 5, and 7mm. For each of these lengths, there are targets with diameters of 3, 5, 7 and 9mm.

CTP486 Uniformity Module Diameter: 15cm Thickness: >40mm spacial uniformity (noise) noise (precision) of CT systems Unique Advantages The CTP486 does not leak and is not damaged by exposure to freezing temperatures because it does not use water. While water is generally considered the standard calibration material, many physicists prefer using our CTP486 solid-image uniformity module because it provides consistent results, is much more convenient to use than modules using water-filled tanks, and eliminates variations due to different water sources. The CTP486 module is cast from a uniform material that has a CT number within 2% (0-20H) of water. This solid material s high radial and axial uniformity makes it an ideal substitute for water. It has been thoroughly tested over a wide variety of variables in the x, y and z planes and has proven stable in all applications.

CTP591 Bead Geometry Module Diameter: 15cm Thickness: 40mm slice width for thin slices slice width for thick slices MTF and SSP with two size point sources test on multiple slices in a multi-slice sequence Unique Advantages The CTP591 Bead Geometry Module contains both coarse ramps with 1mm z axis increments and precision ramps with.25mm z axis increments. To maintain a strong signal with an appropriate diameter, the coarse ramps use 0.28mm diameter tungsten carbide beads while the precision ramps use 0.18mm tungsten carbide beads. The use of beads enables quick assessment and comparison of slice thickness in a multi-slice sequence verifying consistency across the detector area. The unique ramps are positioned in opposed pairs to eliminate errors caused by non-perpendicular alignment. There are 2 pairs of coarse ramps and 1 pair of precision ramps. The coarse ramps each contain 39 beads, transversing all but the last millimeter of the 40mm module. The precision.25mm ramps each contain 25 beads covering a 6mm range. For detailed MTF and SSP calculations, two isolated beads 0.28mm and.018mm in diameter are located in the mid plane of the module. For thin slice high resolution measurements, a 50µ diameter steel MTF wire runs through the full 40mm thickness of the module. Note: This module is ideal for efficient processing by automated software. The IRIS has developed new CT Auto QA software that is specifically designed to measure slice thickness using the bead ramps and calculates the MTF from the offset wire and the two isolated bead impulse sources.

Also available from The Phantom Laboratory Contact Us The Phantom Laboratory is internationally recognized for producing dependable, high-precision phantoms for evaluating the performance of medical imaging and radiation therapy equipment. Magphan Phantom Designed to perform a wide range of precision performance evaluations of Magnetic Resonance Imaging (MRI) Scanners. Specphan Phantom A New Test Tool For Single Photon Emission Computed Tomography (SPECT) and Coincidence Detection Systems. RANDO Phantom Comprehensive verification of the complete treatment planning sequence. The RSVP Phantom Provides stereotactic localization and dose verification for radiosurgery machines. The Phantom Patient A full-body phantom with the dimensions of an average-size male patient, indispensable for training technicians in the use of radiography equipment. Sectional Phantoms Sectional Phantoms are ideal for training, calibration, and research. Liqui-Phil Phantoms Hollow phantoms that can be filled with liquid for nuclear medicine and MRI studies. Custom & OEM Phantoms Designed and manufactured to order. Call for details. Please contact The Phantom Laboratory if you have any questions about our products. PHONE: 518-692-1190 / 800-525-1190 FA: 518-692-3329 MAIL: The Phantom Laboratory, P.O. Box 511, Salem, NY 12865-0511 USA E-MAIL: General info: info@phantomlab.com Eileen Gerdes, Manager Order Desk and Quality Systems: gerdes@phantomlab.com Bonnie Hanlon, Manager Production and Purchasing: hanlon@phantomlab.com Joshua Levy, President levy@phantomlab.com WEB: www.phantomlab.com The Phantom Laboratory is committed to the manufacture of high quality products. Our comprehensive quality system is registered in compliance with the internationally recognized ISO 9001:2000 standards.