PROFIBUS Repeater PRC P PROFIBUS Converter PCF PF P PROFIBUS Converter PCF PF P20.05

Similar documents
PROFIBUS Repeater PRC P PROFIBUS Converter PCF PF P PROFIBUS Converter PCF PF P20.05

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Ethernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.

02. PushPull CONNECTORS

07. har-link Interface Connectors

02. PushPull CONNECTORS

DESINA installation technology

Details of the Han-Terminal block connector Han D AV Han D AV Distributor Han E AV Han ES AV

HARTING News 2007

Industrial Controls Siemens Drives & PLCs

07. har-link INTERFACE CONNECTORS

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.

HARTING. News People Power Partnership

07. har-link Interface Connectors

CONTA-ELECTRONICS. Interface modules

Accessories Fieldbus Box

HARTING econ 3000 Introduction and features

VMEbus systems System description Technical characteristics System description

Applications

04 4E HARTING. Solutions for Industrial Ethernet

HARTING. News People Power Partnership

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

09. DIN Connectors

Technical characteristics A Technical characteristics F.O. termination A Ha-VIS mcon 3100-AV A Ha-VIS mcon 3100-AAV A.

Rotary Measuring Technology Absolute encoders, Multiturn, Profibus-DP

Summary of shell housings and accessories Shell housing A Shell housing D EMC housing

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

CX BD series. Main features MULTIPOLE CONNECTORS CX BD CN

PSI-MOS-PROFIB/FO 850 T

HARTING scon Introduction and features

D-Sub SEaled subminiature D connectors, 2.54 mm pitch

Connect - Contact - Control. Connectors according to UIC VE EP Series. F 121.en

Rotary Measurement Technology Absolute Encoders, Singleturn

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

Directory chapter 05. D-Sub Filter subminiature D connectors, 2.54 mm pitch

TSX SCA 64 connection box

Connector series UIC 558 VE R115. F 120.en

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Rotary Measurement Technology Absolute Encoders, Multiturn

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

Extract from the online catalog

ENCODER. Profibus Multiturn. Series , Key-Features:

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

Description of parts Panel mounting Insert mounting without/with Carrier element Plastic housings

EPIC Circular Connectors CIRCON M23 Series

Ha-VIS mcon 3000 Next Generation Introduction and features

PLC PFC200 Controller PFC200 CS 2ETH RS

Digital electropneumatic positioner

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

PA ROUTERS. The following criteria can be applied when choosing the network transition:

For situations susceptible to interference and safety-related applications

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

5 Fieldbus Technology

revos revos Industrial Multipole Connectors

Fieldbus technology An Overview

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

SUNCLIX Connection technology for photovoltaics

Digital electropneumatic positioner

M12x1 Circular Connectors

HARTING. News People Power Partnership

HARTING. Interface Connectors. People Power Partnership

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Modular Connector System with High Power, Signal, Fibre-Optic, Coaxial Contacts and Pneumatic Valves

Encoders Absolute Singleturn Encoder Types A58CS8

Installation and Setup

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

09. DIN CONNECTORS

VersaMax IP Input Module

CAN 300 PRO, Communication Module

PLIN-LWL Optical Coupler for LIN Data Transmission. User Manual. Document version ( )

PROFIBUS Workshop EN B U I L D I N G P R O C E S S M A N U F A C T U R I N G EUROPEAN FIELDBUS STANDARD. Chapter 1 Date 11/04/99, page 1

Rotary Measuring Technology

FL MC 10/100BASE-T/FO-660

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

Absolute Encoders Multiturn

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

Brief instruction. Version. 3en.

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

DESINA Installation technology

Accessories / 7XV5662

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

ACP 1703 Ax 1703 CM Fieldbus Interface Ring (3x FO, 1x el.)

modlink msdd Front panel interfaces

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

revos revos Industrial Multipole Connectors 3 48 pole in metal housing Program for Tough Tasks

PAS 300, PROFIBUS Slave Interface Module

Extract from new. Device Connectivity catalogue. HARTING har-flex. People Power Partnership

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

SAC-5P-MS/ 1,0-920/FS SCO

Manual Fiber Optic Interfaces

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Safety switches for hinged doors

Transcription:

Contents chapter age General information............................... 00 Repeater.......................................... 10 Repeater RC 67-10............................... 10.01 Converter......................................... 20 Converter CF 67-10 F660......................... 20.01 Converter CF 20-10 F660......................... 20.05 Converter CF 20-10 GF850......................... 20.08 System cables............................................... 60 Connectors................................................. 70 Accessories................................................ 90 00. 01

An Overview 00 General information about is a multi-vendor, open fieldbus standard for diverse applications in manufacturing, process and building automation. Manufacturer independence and openness are guaranteed by the international standard EN 50 170. makes it possible for devices from different manufacturers to communicate, without special adaptation of the interfaces. is suitable for both fast, time-critical data transmissions as well extensive and complex communication tasks. Amongst others, is based on the following standards: Standard / guidelines EN 50 170 IEC 61 158 IEC 61 784 guideline guideline guideline 2.021 guideline 2.111 guideline 2.122 guideline 2.142 Designation specification Digital data communication for measurement and control fieldbus for use in industrial control systems rofile sets for continuous and discrete manufacturing Data Link Layer Application Layer Fibre optical data transfer for Installation Guideline for -D/FMS GSD Specification (Device Database Files) Interconnection Technology -FMS 00.1 Data transmission -FMS (Fieldbus Message Specification) is the universal solution for communication tasks on the cell level. The powerful FMS services open up a wide range of applications as well as providing greater flexibility. FMS is also suitable for extensive communication tasks. From an historical point of view, - FMS is the forerunner to -D. -D -D (Decentralized eripherals) has been optimised for speed and low connection costs. This variant of has been specially tailored for communication between automation systems and remote periphery devices on the field level. - D is a suitable substitute for the conventional, parallel transmission of signals via 24 V DC or 0/4 20 ma. In contrast to -FMS, a special characteristic boasted by -D is that it does not use layer 7 of the OSI Reference Model. fieldbus works according to the masterslave process. That means there is only ever one active master within the entire bus structure regulating all of the communication across the bus. All other stations function as slaves. Network configurations in which several stations can be configured as masters are possible. In this case, the network functions according to the 'token passing procedure'. That means when a predefined time elapses the currently active master passes on transmission rights (the token) to the next master before becoming inactive, remaining so until it in turn receives the token again. In such a network, all masters are connected in a logical ring structure that determines the order in which the masters receive the token. Transmission technologies Essentially, uses the following transmission technologies: l RS 485 l Fibre-optic cable 00. 02 RS 485 is the most prevalent. This transmission technology uses twisted and shielded two-wire cables. The following table offers a comparison of the two transmission technologies:

An Overview RS485 Fibre-optic cable Data transmission l Digital l Optical l Differential signals to RS485 l Digital Transmission rate 9.6 to 12000 Kbit/s Data security l Hamming distance = 4 l arity bit l Start and end delimiter Cable Twisted and shielded two-wire l Glass fibre cable, type A l olymer optical fibre (OF) Remote powering ossible via additional wires (hybrid cable) Topology Line topology with termination l Star and ring topologies are typical l Line topology possible Number of stations l Up to 32 stations per segment Up to 126 stations per network l without repeaters l Up to 126 stations per network l with repeaters Number of repeaters Maximum of 9 repeaters with Unlimited with signal regeneration signal regeneration (signal propagation time must be observed) Address configuration for the fieldbus Each station on the network is assigned a unique address within the range 000 to 125 (-D) or between 000 and 126 (-FMS). Each address must be assigned only once within the entire bus structure. The address 127 must not be assigned. It is reserved as the global address for 'broadcast' and 'multicast' messages. Device database files (DDBF) Device database files (also known by the German abbreviation GSD) contain characteristics, parameters and configuration data of each station on a network. Each active station on a network has its own DDB file (GSD). The structure and content of the DDB file (GSD) must comply with the guideline 2.122. This is essentially made up of three sections: l General definitions This section contains general information such as manufacturer and device name, version number, and date of manufacture, supported transmission rates as well as signal assignment for the bus connector. l Master definitions All parameters applicable only to master devices are entered into this section. These include, amongst others, the maximum possible number of slaves that can be connected as well as the possible upload and download options available. l Slave definitions This section contains all relevant slave details. These include, amongst others, the number of I/O channels, the definition of diagnostic, configuration and parameter texts as well as the number of possible modules for modular devices. Each manufacturer must present his DDB file(s) (GSD) to the User Organisation when certifying his device. 00.2 Topology networks can be set up as either a line or a tree topology. assive branch lines should be avoided. If a device is used as the first or last station, it is necessary to terminate the network with an active terminating resistor (integrated or switchable) in order to guarantee an error-free communication across the whole bus. Maximum system extension A maximum of 32 stations (1 master and 31 slaves) can be connected in a network. If more than 32 stations are required, repeaters must be used to create appropriate segments. It is recommended that no more than 4 repeaters be used within a network, because these cause signal delays. When used, repeaters count as stations on the bus, although they do not require an address of their own. 00. 03

An Overview rogrammable Logic Controller with interface ( Master 000) C with card ( Master 001) Terminating Resistor Bus line Terminating Resistor Maximum system extension without repeater rogrammable Logic Controller with interface ( Master 000) C with card ( Master 001) Terminating Resistor Bus line Terminating Resistor 00. 04 Maximum system extension with repeater

An Overview Maximum length of the bus The required transmission rate plays a decisive role in deciding the maximum length of the bus. The following table provides an overview of the individual transmission rates and the corresponding maximum bus lengths for RS 485: Transmission rate Maximum length per segment 9.60 Kbit/s 1200 m 19.20 Kbit/s 1200 m 45.45 Kbit/s 1200 m 93.75 Kbit/s 1200 m 187.50 Kbit/s 1000 m 500,75 Kbit/s 400 m 1500,75 Kbit/s 200 m 3000,75 Kbit/s 100 m 6000,75 Kbit/s 100 m 12000,75 Kbit/s 100 m The following cables with RS 485 connectors can be used for : l Twisted and shielded two-wire cables l Twisted and shielded hybrid cables As well as the actual cable, hybrid cables also carry integrated wiring for the 24 V DC power supply. Schematic view of cable, two-wire RS485 00.3 Types of cables Furthermore, it should be observed that the set transmission rate applies to the entire bus network and must be supported by all stations (master and slaves). Transmission in accordance with RS 485 Transmissions according to RS 485 specifications require that the cables used have the following characteristics: arameter Characteristic impedance Capacitance per unit length Loop resistance Wire diameter Wire cross-section Terminating resistors Cable Type A acc. to DIN 19 245 part 3 135 to 165 Ω (3 to 20 MHz) < 30 nf/km < 110 Ω/km > 0.64 mm > 0.34 mm² 220 Ω Schematic view of cable, Hybrid cable RS485 Transmissions with fibre-optic cables The following cables are used for transmissions with fibre-optics: l OF 1) 980/1000 µm l HCS 2) 200/230 µm l OF 1) 980/1000 µm, hybrid cables l HCS 2) 200/230 µm, hybrid cables As well as the actual fibre-optic cable, hybrid cables also carry integrated wiring for the 24 V DC power supply. 1) OF = olymer optical fibre 2) HCS = Hard Clad Silica (registered trademark of SpecTran Corporation) 00. 05

An Overview 00.4 Connectors Differences between connectors for RS 485 interfaces are based on their protection class: l In protection class I 20, a 9-pole D-Sub plug-in connector is predominantly used. l In protection class I 65 / I 67, the following alternatives are recommended: l M12 circular connectors according to IEC 61 072-2-101 l Han-Brid connectors in accordance with DESINA recommendations The following figure depicts the pin assignment for a female socket and a male connector with protection class I 20. A terminating resistor is necessary for the first or last station of a section of network. As a rule, a connector with an integrated or switchable terminating resistor is used. When using fibre-optic cables, a distinction is made between crimped or crimpless contacts. Crimpless contacts are generally only used for test purposes or within a confined space. As a rule, Han-Brid connectors are used for hybrid cables with integrated fibre-optics. Fibre Optical cable Data conductors A and B 5 4 3 2 1 1 2 3 4 5 Cables for ower supply 9 8 7 6 6 7 8 9 in assignment for female socket and male socket RS 485 Connection options in the Han-Brid connector for fibre-optics in Signal Description 1 - not assigned 2 - not assigned 3 RxD/TxD- Receive/transmission-data cable A 4 - not assigned 5 DGND Data reference potential 6 V + 5 V DC for external bus termination 7 - not assigned 8 RxD/TxD-N Receive/transmission-data cable B 9 - not assigned in assignment for D-SUB 00. 06

Han-InduNet Repeater RC 67-10 General description Advantages The Repeater RC 67-10 with automatic transmission rate detection offers a high degree of protection due to a robust metal housing. It can be used directly in industrial environments. Thus it is possible to reduce termination time to set up networks. l High protection degree I 67 l Suitable for the use directly in industrial environments l All terminals are connectorized All terminals are connectorized, thus a secure and quick assembly is guaranteed. All interfaces are protected against overvoltages. l Hybrid wiring possible l Signal regeneration l lug & lay installation l T-functionality Technical characteristics Housing and Assembly Housing robust metal housing of zinc die cast Dimensions 45 x 120 x 87 (W x D x H in mm, without connector) Assembly 35 mm standard rail acc. to DIN EN 60 715 panel mounting fixation for upright assembly panel mounting fixation for flat assembly ower Supply Input voltage Current consumption 24 V DC (18 30 V DC) typical 250 ma (at 24 V DC) Interface Supported bus structures point to point, star topology, line topology Data transmission rate automatic transmission rate detection, max. 12 MBit/s Cable acc. to DIN EN 50 170 Terminals all connectorized with Han-Brid Cu connector Maximum cable length acc. to DIN EN 50 170 Environmental conditions Degree of protection I 67 Operating temperature 0 C to +55 C Operating humidity 30% to 95%, not condensing 10. 01

Han-InduNet Identification art No. Drawing Dimensions in mm RC 67-10 Repeater for star and line topology Han-Brid Cu: male, female, female 20 70 304 3641 Accessories art No. Drawing Dimensions in mm Set for assembly on standard rail acc. to DIN EN 60 715 20 80 000 0003 Set for panel mounting upright assembly 20 80 024 0001 Set for panel mounting flat assembly 20 80 024 0002 10. 02 Stock items in bold type

Connectors and cables for RC 67-10 Connectors for Han-Brid Cu Identification art No. Han-Brid Cu-female Female insert Han-Brid Cu 09 12 006 3111 Hood, metal, top entry, metric, with glued sealing 19 20 003 1443 Sealing screw for hood 09 20 000 9918 Cable gland metric M20, metal, I65, for cable diameter 6 to 12 mm 19 00 000 5082 rotection cover Han 3A, metal, with glued sealing 09 20 003 5425 Han-Brid Cu-male Male insert Han-Brid Cu 09 12 006 3001 Hood, metal, top entry, metric, with glued sealing 19 20 003 1443 Sealing screw for hood 09 20 000 9918 Cable gland metric M20, metal, I65, for cable diameter 6 to 12 mm 19 00 000 5082 rotection cover Han 3A, metal, with glued sealing 09 20 003 5425 Crimp contacts Contacts Wire gauge Stripping Diameter [mm²] AWG length art No. Han D Cu male contacts for Han-Brid Cu-male silver plated 0.14-0.37 26-22 0.90 mm 8 mm 09 15 000 6104 0.50 20 1.10 mm 8 mm 09 15 000 6103 0.75 18 1.30 mm 8 mm 09 15 000 6105 1.00 18 1.45 mm 8 mm 09 15 000 6102 1.50 16 1.75 mm 8 mm 09 15 000 6101 2.50 14 2.25 mm 6 mm 09 15 000 6106 gold plated 0.14-0.37 26-22 0.90 mm 8 mm 09 15 000 6124 0.50 20 1.10 mm 8 mm 09 15 000 6123 0.75 18 1.30 mm 8 mm 09 15 000 6125 1.00 18 1.45 mm 8 mm 09 15 000 6122 1.50 16 1.75 mm 8 mm 09 15 000 6121 2.50 14 2.25 mm 6 mm 09 15 000 6126 Han D Cu female contacts for Han-Brid Cu-female silver plated 0.14-0.37 26-22 0.90 mm 8 mm 09 15 000 6204 0.50 20 1.10 mm 8 mm 09 15 000 6203 0.75 18 1.30 mm 8 mm 09 15 000 6205 1.00 18 1.45 mm 8 mm 09 15 000 6202 1.50 16 1.75 mm 8 mm 09 15 000 6201 2.50 14 2.25 mm 6 mm 09 15 000 6206 gold plated 0.14-0.37 26-22 0.90 mm 8 mm 09 15 000 6224 0.50 20 1.10 mm 8 mm 09 15 000 6223 0.75 18 1.30 mm 8 mm 09 15 000 6225 1.00 18 1.45 mm 8 mm 09 15 000 6222 1.50 16 1.75 mm 8 mm 09 15 000 6221 2.50 14 2.25 mm 6 mm 09 15 000 6226 Cables for Cu-Connection Type of fibre Drawing Cable length* art No. Hybrid cable Cu-Cu 4 x 1.5 mm², contacts silver plated 2 x 0.3 mm², contacts silver plated 1.5 m 3.0 m 5.0 m 20 88 651 0015 20 88 651 0030 20 88 651 0050 pre-assembled on both sides, 10.0 m 20 88 651 0100 metal hood, top entry 15.0 m 20 88 651 0150 Cable length* 30.0 m 20 88 651 0300 * Other cable lengths and configurations on request Accessories for Cu assembly Tool Accessories Wire gauge art No. HARTING Service Crimping tool 0.14 to 2.5 mm² 09 99 000 0021 HARTING Crimping tool 09 99 000 0110 Locator 09 99 000 0111 Stock items in bold type 10. 03

Notes 10. 04

Han-InduNet Converter CF 67-10 F660 General description Advantages The Converter CF 67-10 F660 offers a high degree of protection due to a robust metal housing. It can be used directly in industrial environments. l High protection degree I 67 l Suitable for the use directly in the industrial environments All terminals are connectorized, thus a secure and quick assembly is guaranteed. The CF 67-10 F660 is suitable for star as well as for line topology. All interfaces are protected against overvoltages. l All terminals are connectorized l ossibility to set up optical bus systems for -FMS/D l lug & lay installation l T-functionality Technical characteristics Housing and Assembly Housing robust metal housing of zinc die cast Dimensions 45 x 120 x 87 (W x D x H in mm, without connector) Assembly 35 mm standard rail acc. to DIN EN 60 715 panel mounting fixation for upright assembly panel mounting fixation for flat assembly ower Supply Input voltage Current consumption 24 V DC (18 30 V DC) typical 250 ma (at 24 V DC) /F.O. Interface Supported bus structures Data transmission rate Terminals Suitable fibre types 660 nm point to point, star topology, line topology automatic transmission rate detection, max. 12 MBit/s all connectorized with Han-Brid Cu and Han-Brid F.O. connector OF 1) 980/1000 µm, max. transmission distance 50 m HCS 2) 200/230 µm, max. transmission distance 300 m Environmental conditions Degree of protection I 67 Operating temperature 0 C to +55 C Operating humidity 30% to 95%, not condensing 1) OF = olymer optical fibre 2) HCS = Hard Clad Silica (registered trademark of SpecTran Corporation) 20. 01

Han-InduNet Identification art No. Drawing Dimensions in mm CF 67-10 F660 Converter for star topology Han-Brid Cu: male Han-Brid F.O.: female, female 20 42 304 3641 CF 67-10 F660 Converter for line topology Han-Brid Cu: female Han-Brid F.O.: male, female 20 42 304 3642 Accessories art No. Drawing Dimensions in mm Set for assembly on standard rail acc. to DIN EN 60 715 20 80 000 0003 Set for panel mounting upright assembly 20 80 024 0001 Set for panel mounting flat assembly 20 80 024 0002 20. 02 Stock items in bold type

Connectors and cables for CF 67-10 F660 Connectors for Han-Brid Cu Identification art No. Han-Brid Cu-female Female insert Han-Brid Cu 09 12 006 3111 Hood, metal, top entry, metric, with glued sealing 19 20 003 1443 Sealing screw for hood 09 20 000 9918 Cable gland metric M20, metal, I65, for cable diameter 6 to 12 mm 19 00 000 5082 rotection cover Han 3 A, metal, with glued sealing 09 20 003 5425 Connectors for Han-Brid F.O. Identification art No. Han-Brid F.O.-male Male insert Han-Brid F.O. 09 12 004 2601 Crimp contact Hood, metal, top entry, metric, with glued sealing 19 20 003 1443 Sealing screw for hood 09 20 000 9918 Cable gland metric M20, metal, I65, for cable diameter 6 to 12 mm 19 00 000 5082 rotection cover Han 3 A, metal, with glued sealing 09 20 003 5425 Han-Brid F.O.-male Male insert Han-Brid F.O. 09 12 004 2603 Crimpless contact Hood, metal, top entry, metric, with glued sealing 19 20 003 1443 Sealing screw for hood 09 20 000 9918 Cable gland metric M20, metal, I65, for cable diameter 6 to 12 mm 19 00 000 5082 rotection cover Han 3 A, metal, with glued sealing 09 20 003 5425 Han-Brid F.O.-male Male insert Han-Brid F.O. 09 12 004 2606 HCS 1) Hood, metal, top entry, metric, with glued sealing 19 20 003 1443 Sealing screw for hood 09 20 000 9918 Cable gland metric M20, metal, I65, for cable diameter 6 to 12 mm 19 00 000 5082 rotection cover Han 3 A, metal, with glued sealing 09 20 003 5425 Han-Brid F.O.-female Female insert Han-Brid F.O. 09 12 004 2711 Crimp contact Hood, metal, top entry, metric, with glued sealing 19 20 003 1443 Sealing screw for hood 09 20 000 9918 Cable gland metric M20, metal, I65, for cable diameter 6 to 12 mm 19 00 000 5082 rotection cover Han 3 A, metal, with glued sealing 09 20 003 5425 Han-Brid F.O.-female Female insert Han-Brid F.O. 09 12 004 2713 Crimpless Hood, metal, top entry, metric, with glued sealing 19 20 003 1443 Sealing screw for hood 09 20 000 9918 Cable gland metric M20, metal, I65, for cable diameter 6 to 12 mm 19 00 000 5082 rotection cover Han 3 A, metal, with glued sealing 09 20 003 5425 Han-Brid F.O.-female Female insert Han-Brid F.O. 09 12 004 2716 HCS 1) Hood, metal, top entry, metric, with glued sealing 19 20 003 1443 Sealing screw for hood 09 20 000 9918 Cable gland metric M20, metal, I65, for cable diameter 6 to 12 mm 19 00 000 5082 rotection cover Han 3 A, metal, with glued sealing 09 20 003 5425 Crimp contacts Contacts Wire gauge Stripping Diameter [mm²] AWG length art No. Han D male contacts for Han-Brid Cu-male / Han-Brid F.O.-male* silver plated 0.14-0.37 26-22 0.90 mm 8 mm 09 15 000 6104 0.50 20 1.10 mm 8 mm 09 15 000 6103 0.75 18 1.30 mm 8 mm 09 15 000 6105 1.00 18 1.45 mm 8 mm 09 15 000 6102 1.50 16 1.75 mm 8 mm 09 15 000 6101 2.50 14 2.25 mm 6 mm 09 15 000 6106 gold plated 0.14-0.37 26-22 0.90 mm 8 mm 09 15 000 6124 0.50 20 1.10 mm 8 mm 09 15 000 6123 0.75 18 1.30 mm 8 mm 09 15 000 6125 1.00 18 1.45 mm 8 mm 09 15 000 6122 1.50 16 1.75 mm 8 mm 09 15 000 6121 2.50 14 2.25 mm 6 mm 09 15 000 6126 * for Han-Brid F.O. the 24 V DC-contacts only 1) HCS = Hard Clad Silica (registered trademark of SpecTran Corporation) Stock items in bold type 20. 03

Connectors and cables for CF 67-10 F660 Crimp contacts Contacts Wire gauge Stripping Diameter [mm²] AWG length art No. Han D female contacts for Han-Brid Cu-female / Han-Brid F.O.-female* silver plated 0.14-0.37 26-22 0.90 mm 8 mm 09 15 000 6204 0.50 20 1.10 mm 8 mm 09 15 000 6203 0.75 18 1.30 mm 8 mm 09 15 000 6205 1.00 18 1.45 mm 8 mm 09 15 000 6202 1.50 16 1.75 mm 8 mm 09 15 000 6201 2.50 14 2.25 mm 6 mm 09 15 000 6206 gold plated 0.14-0.37 26-22 0.90 mm 8 mm 09 15 000 6224 0.50 20 1.10 mm 8 mm 09 15 000 6223 0.75 18 1.30 mm 8 mm 09 15 000 6225 1.00 18 1.45 mm 8 mm 09 15 000 6222 1.50 16 1.75 mm 8 mm 09 15 000 6221 2.50 14 2.25 mm 6 mm 09 15 000 6226 * for Han-Brid F.O. the 24 V DC-contacts only 20. 04 F.O. contacts Connector Contact art No. Han-Brid F.O. Crimp contact Hewlett ackard Versatile Link Crimp contacts 20 10 001 7111 Han-Brid F.O. Crimpless contact Hewlett ackard Versatile Link Crimpless contacts 20 10 001 7112 Han-Brid F.O. HCS 1) HCS 1) 20 10 230 7111 Cables for Cu connection Type of fibre Drawing Cable length* art No. Hybrid cable Cu-Cu 4 x 1.5 mm², contacts silver plated 2 x 0.3 mm², contacts silver plated 1.5 m 3.0 m 5.0 m 20 88 651 0015 20 88 651 0030 20 88 651 0050 pre-assembled on both sides, 10.0 m 20 88 651 0100 metal hood, top entry 15.0 m 20 88 651 0150 Cable length* 30.0 m 20 88 651 0300 * Other cable lengths and configurations on request Cables for F.O. connection Type of fibre Drawing Cable length* art No. Hybrid cable Cu-F.O. 4 x 1.5 mm², contacts silver plated 2 x OF 980/1000 µm 1.5 m 3.0 m 5.0 m 20 88 451 0015 20 88 451 0030 20 88 451 0050 pre-assembled on both sides, 10.0 m 20 88 451 0100 metal hood, top entry 15.0 m 20 88 451 0150 Cable length* 30.0 m 20 88 451 0300 * Other cable lengths and configurations on request Accessories for Cu assembly Tool Accessories Wire gauge art No. HARTING Service Crimping tool 0.14 to 2.5 mm² 09 99 000 0021 HARTING Crimping tool 09 99 000 0110 Locator 0.14 to 1.5 mm² 09 99 000 0111 Locator 0.5 to 2.5 mm² 09 99 000 0112 Accessories for F.O. assembly Identification art No. Han-Brid -Crimping tool 09 99 000 0362 olishing set 20 80 001 9914 Abrasive paper in grit size 1000µ 20 80 001 9911 1) HCS = Hard Clad Silica (registered trademark of SpecTran Corporation) Stock items in bold type

Han-InduNet Converter CF 20-10 F660 General description Advantages The Converter CF 20-10 F660 allows to set up networks with OF 1) or HCS 2) fibres (λ = 660 nm). l ossibility to set up optical bus systems for -FMS/D CF 20-10 F660 is suitable for the assembly on standard rail as well as for the assembly directly on the panel within switch cabinets and termination boxes. l Signal regeneration l lug & lay installation All interfaces are protected against overvoltages. l T-functionality Technical characteristics Housing and Assembly Housing robust metal housing of zinc die cast Dimensions 45 x 120 x 87 (W x D x H in mm, without connector) Assembly 35 mm standard rail acc. to DIN EN 60 715 panel mounting fixation for upright assembly panel mounting fixation for flat assembly ower Supply Input voltage Current consumption Interface 24 V DC (18 30 V DC) typical 250 ma (at 24 V DC) 4 pole screw terminal connectorized for redundant power supply /F.O. Interface Supported bus structures Data transmission rate Terminals Suitable fibre types 660 nm point to point, star topology, line topology automatic transmission rate detection, max. 12 MBit/s 2 optical ports 660 nm: H Versatile Link : D-Sub 9pin female OF 1) 980/1000 µm, max. transmission distance 50 m HCS 2) 200/230 µm, max. transmission distance 300 m Environmental conditions Degree of protection I 20 Operating temperature 0 C to +55 C Operating humidity 30% to 95%, not condensing 1) OF = olymer optical fibre 2) HCS = Hard Clad Silica (registered trademark of SpecTran Corporation) 20. 05

Han-InduNet Identification art No. Drawing Dimensions in mm CF 20-10 F660 Converter 2 optical ports 660 nm, OF 1) /HCS 2) 20 42 004 3646 Accessories art No. Drawing Dimensions in mm Set for assembly on standard rail acc. to DIN EN 60 715 20 80 000 0003 Set for panel mounting upright assembly 20 80 024 0001 Set for panel mounting flat assembly 20 80 024 0002 20. 06 Hewlett ackard Versatile Link Crimp contacts Hewlett ackard Versatile Link Crimpless contacts 20 10 001 7111 20 10 001 7112 HCS 2) 20 10 230 7111 1) OF = olymer optical fibre 2) HCS = Hard Clad Silica (registered trademark of SpecTran Corporation) Stock items in bold type

Connectors and cables for CF 20-10 F660 Connectors for Fibre Optic OF 1) Identification art No. Hewlett ackard Versatile Link Crimp contacts 20 10 001 7111 Hewlett ackard Versatile Link Crimpless contacts 20 10 001 7112 HCS 2) 20 10 230 7111 Accessories for F.O. assembly Identification art No. Han-Brid -Crimping tool 09 99 000 0362 olishing set 20 80 001 9914 Abrasive paper in grit size 1000 µm 20 80 001 9911 1) OF = olymer optical fibre 2) HCS = Hard Clad Silica (registered trademark of SpecTran Corporation) Stock items in bold type 20. 07

Han-InduNet Converter CF 20-10 GF850 General description Advantages The Converter CF 20-10 GF850 allows to set up networks with glass fibres (λ = 850 nm). l ossibility to set up optical bus systems for FMS/D CF 20-10 GF850 is suitable for the assembly on standard rail as well as for the assembly directly on the panel within switch cabinets and termination boxes. All interfaces are protected against overvoltages. l Signal regeneration l lug & lay installation l T-functionality Technical characteristics Housing and Assembly Housing robust metal housing of zinc die cast Dimensions 45 x 120 x 87 (W x D x H in mm, without connector) Assembly 35 mm standard rail acc. to DIN EN 60 715 panel mounting fixation for upright assembly panel mounting fixation for flat assembly ower Supply Input voltage Current consumption Interface 24 V DC (18 30 V DC) typical 250 ma (at 24 V DC) 4-pole screw terminal connectorized for redundant power supply /F.O. Interface Supported bus structures Data transmission rate Terminals Suitable fibre types 850 nm point to point, star topology, line topology automatic transmission rate detection, max. 12 MBit/s 2 optical ports 850 nm: F-ST : D-Sub 9pin female GI 50 µm / 125 µm, max. transmission distance 2500 m 20. 08 Environmental conditions Degree of protection I 20 Operating temperature 0 C to +55 C Operating humidity 30% to 95%, not condensing

Han-InduNet Identification art No. Drawing Dimensions in mm CF 20-10 GF850 Converter 2 optical ports 850 nm 20 52 004 3626 Accessories art No. Drawing Dimensions in mm Set for assembly on standard rail acc. to DIN EN 60 715 20 80 000 0003 Set for panel mounting upright assembly 20 80 024 0001 Set for panel mounting flat assembly 20 80 024 0002 Stock items in bold type 20. 09

Connectors and cables for CF 20-10 GF850 Connectors for Fibre optic Glass fibres Identification art No. F.O. connector type F-ST for cables Ø 2.8 mm 20 10 125 2212 Accessories for F.O. assembly Identification art No. Fibre stripper 0.3 mm 20 99 000 1046 Fibre stripper 0.18 mm 20 99 000 1046 Epoxy adhesive for glass fibre 20 80 001 9902 Han-Brid -Crimping tool 20 99 000 1031 olishing tool 20 99 000 1095 olishing paper 9 µ-grain size 20 80 001 9912 olishing paper 1 µ-grain size 20 80 001 9913 Tool kit GI-fibre 20 99 000 3015 20. 10