New Data Center and Transport Interconnect Technology

Similar documents
100G and Beyond: high-density Ethernet interconnects

100 GBE - WHAT'S NEW AND WHAT'S NEXT

400GE at the Cost of 4 x 100GE

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

Pivotal Issues for 400 Gb/s Ethernet

Ethernet evolution: what s new and what s next

Ethernet The Next Generation

Future Datacenter Interfaces Based on Existing and Emerging Technologies

Arista 400G Transceivers and Cables: Q&A

Ethernet 100G and Beyond

400G PAM4 The Wave of the Future. Michael G. Furlong - Senior Director, Product Marketing

SLIDE 1 - COPYRIGHT G. Across the country, Across the Data Centre. Tim Rayner. Optical Engineer, AARNet.

Fiber Optic Cabling Systems for High Performance Applications

Delivering100G and Beyond. Steve Jones Phone: blog.cubeoptics.

Higher Speed Ethernet

Objectives for HSSG. Peter Tomaszewski Scientist, Signal Integrity & Packaging. rev3 IEEE Knoxville Interim Meeting, September 2006

Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

CDFP MSA Delivers 400 Gb/s Today

100 Gigabit Ethernet. An Industry Update. John D Ambrosia Chair, IEEE P802.3ba Task Force Senior Scientist, Force10 Networks October 8, 2009

Cisco 100GBASE QSFP-100G Modules

100 GIGABIT ETHERNET. So we ve got 802.3ba, now what do we do with it? Chris Bull Service Provider ANZ

QSFP-DD: Enabling 15 Watt Cooling Solutions

Active Optical Cable. Optical Interconnection Design Innovator 25G SFP28 AOC 10G SFP+ AOC. Shenzhen Gigalight Technology Co.,Ltd.

ETHERNET OPTICS TODAY: 25G NRZ

Disruptive Technologies Shaping Data Center Growth

Optics Modules and Cables Data Sheet

40 Gigabit and 100 Gigabit Ethernet Are Here!

OptiDriver 100 Gbps Application Suite

Objectives for Next Generation 100GbE Optical Interfaces

100G-Optics Next Gen Possible PMD Set

QDR Active Optical Cables. SC 10 New Orleans

DC Network Connectivity

Real World Deployment Experience With 100G Optical Transport & 100GE Technologies. Sterling Perrin Senior Analyst Heavy Reading

Dell Networking Optics and Cables Connectivity Guide

Overview Brochure Direct attach and active optical cables

100GE 500m SMF Parallel and WDM links

Optics Modules and Cables Data Sheet

DELL EMC NETWORKING TRANSCEIVERS AND CABLES

Cisco 25G Transceivers and Cables Enable 25 Gigabit Ethernet over a Fiber or Copper Cable

Fast Lanes and Speed Bumps on the Road To Higher-Performance, Higher-Speed Networking

ETHERNET ROADMAP UPDATE. Scott Kipp October 2014

10GbE and Beyond. Jeff Cain. Joint Techs Council February 13, 2007

Cisco 40GBASE QSFP Modules

Expanding your network horizons

100 Gb/s SMF Standard Broad Market Potential Observations

Alternate Path to Consensus on 400 GbE PMDs

ARISTA WHITE PAPER Arista 7500E Series Interface Flexibility

Arista 7500 Series Interface Flexibility

Cisco 100GBASE QSFP-100G Modules

OFC/NFOEC 2011 Interoperability Demonstration

Reflex Photonics Inc. The Light on Board Company. Document #: LA Rev 3.1 June 2009 Slide 1

QSFP (Quad Small Form-factor Pluggable) Products

IEEE Liaison report (Oct ) T v000 Tom Palkert, Macom

In Support of a 500m objective for 200G Ethernet: Part II

MDI for 4x25G Copper and Fiber Optic IO. Quadra (CFP4 proposal) Connector System

Timeline Implications

40G and 100G Products

ProLabs Introduction. Tuesday 11th October,

400GBase-LR8: A Proposal for 10 km Objective Using 50 Gb/s PAM4 Signaling

Roadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER

40 Gbit/s Small-Form Low-Power Optical Transceiver

Optical Fiber Networks: Industry. and New Options for Networks

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

Next-gen 400 and 200 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation. IEEE Draft 0.3

Optical multi-speed splitting

Data Center architecture trends and their impact on PMD requirements

High Speed Optics and Cabling for Data Center Fabrics

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress

Data Center Connectivity

The Dawn of Channelized Ethernet

Supported Hardware Components

100 GBE AND BEYOND. Diagram courtesy of the CFP MSA Brocade Communications Systems, Inc. v /11/21

Solutions Guide. Pluggable Optics for the Data Center

The Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers.

Solutions Guide. Pluggable Optics for the Data Center

NGBASE-T Cabling Requirements

25 Gb/s Ethernet Study Group CSD: Technical Feasibility. Joel Goergen - Cisco Matt Brown APM Version goergen_25ge_01_0914d

within IEEE Alan Flatman LAN Technologies

50G and 100G Use Cases. Brad Booth Azure Networking, Microsoft

Technical Feasibility of 4x10G and 10x10G Electrical Interfaces

Path to Consensus on 400 GbE PMDs

802.3bj FEC Overview and Status 400GbE Logic Challenges DRAFT IEEE

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope

IEEE P802.3ba 40 GbE and 100 GbE Standards Update

Trends in Optical Interconnects: Size, Power, Cost Jörg Wieland, GigOptix-Helix AG

Consensus building discussion on next-generation MMF PMDs. Presented by Robert Lingle, Jr. IEEE Interim Huntington Beach, CA January 9 th, 2017

PTX5000 and PTX3000 PICs

Trends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions

Cisco Digital CFP2 Pluggable Optical Module

Optical Transceivers for 100GE

Building Tomorrow s Networks Session #1: New High-Speed and Long Reach Optical Interfaces. January 20, 2018

Pluggable DWDM: Considerations For Campus and Metro DCI Applications

Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables

WHITE PAPER THE CASE FOR 25 AND 50 GIGABIT ETHERNET WHITE PAPER

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

40 and 100 Gigabit Ethernet Overview

100G / Lane Electrical Interfaces for Datacenter Switching - Desirable Solution Attributes

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions

40GBase QSFP+ PSM4 1.5km Optical Transceiver

Transcription:

New Data Center and Transport Interconnect Technology Tom McDermott Fujitsu Network Communications, Inc. October 30, 2014

Changing Requirements Datacenters are expanding in size. Continued need for 100m / MMF intra-dc connection. Growing need for 500m~2km / SMF intra-dc connections. Interest in breakout / fanout capabilities Ethernet WAN / Transport Interconnect. 2km, 10km, 40km continued need. SMF 100GE. 2 nd generation of devices becoming available. Smaller size, lower cost, lower power. 400GE project started. Intra-DC, Inter-DC, and Metro reach objectives. New class of coherent tunable pluggable T/Rs. Metro reach & compatible with ROADMs Optical reach over ROADM still TBD. 1

Some Ethernet PMD Nomenclature 100GBASE-SR4 100GE Short Reach (100 m) over MMF 4 optical lanes 100GBASE-LR4 = 10 km over duplex SMF ER4 = 30 km (40 km with engineering). 100GBASE-CR4 = 4 Copper twin-ax cables (each direction) ~ 5m 100GBASE-KR4 & KP4 = 4 Copper backplane diff traces (each direction) ~ 1m 2

Breakout / Fanout Growing interest in breakout / fanout functionality Increase density in top of rack (TOR) switches Example: a 40GE 40GBASE-SR4 module could be operated in two modes: 4 x 10GE QSFP+ physically smaller than 4 separate 1 x 10GE plugs 1 x 40GE data is striped across the 4 lanes. Provides high-density 10GE fanout from TOR switch Fiber-ribbon to duplex fiber conversion is external. Recent discussion: 100GE 4-lane module (4 x 25G VCSEL): 4 x 25GE 1 x 100GE - An IEEE 802.3 25GE Study Group is underway. - 802.3bm currently balloting 100GBASE-SR4 MMF ribbon Passive 3

Density Evolution 10GE 100GE 2002 2014 Front-Panel Bandwidth Density (GB per 10 mm) 73 58.4 37.7 QSFP28 CFP4 (2008-2010) CXP (MMF) (2014) 29.2 27.4 QSFP (MMF) QSFP+ (MMF) (2006) (2013) CPAK CFP2 (2012) (2012) 13.7 7.30 5.45 (2002) SFP+ XFP 4 x SFP+ 4 x XFP CFP (x 4) (2010) (x 4) 10G Port Bandwidth 40G 100G 4

100GE Package Evolution Today: CFP: 10x10MSA, 100GBASE-LR4 100GBASE-ER4 100GBASE-SR10 Future: Digital DWDM Coherent CFP 100G CFP2 QSFP28 CFP4 Today: CFP2: 100GBASE-LR4, 100GBASE-ER4 10x10MSA? (v2), Future: Analog Coherent DWDM 10 x 10G Digital Electrical I/O + 4 x 25G Digital Electrical I/O + 4 x 25G Analog I/O 10 x 10G Digital Electrical I/O QSFP28: 100GBASE-SR4, 100GBASE-CR4 (copper) 4 x 25G Digital Electrical I/O 5

CFP / CFP2 / CFP4 Client Devices Gen 1 10 x 10G Digital 10:4 Gearbox + Retime 4 x Driver 4 x Receiver 4 x TOSA + WDM WDM + 4 x ROSA Optical I/O ~24w CFP Client Gen 2 4 x 25G Digita al (10x10MSA version is 10 parallel channels at 10G) 4 x Retime + Driver 4 x Receiver + Retime Integrated Multidevice TOSA+ROSA + WDMs Optical I/O 8~12w CFP2 Client Future 4 x 25G Analog 4 x Retime + Driver 4 x Receiver + Retime 4 x VCSEL 4 x PIN Optical I/O 100m ~4.5w CFP4 or QSFP28 Client Fujitsu Proprietary and Confidential 6

100GBASE-SR10 vs. 100GBASE-SR4 Generation 1, CFP form factor : Generation 2, QSFP28 form factor CAUI-10 Electrical Interface 10 x retime & VCSEL driver 10 x PIN receive amp & retime 10 fiber MMF 10 fiber MMF MPO optical connector Generation 1 100GBASE-SR10 10G / lane CFP CAUI-4 Electrical Interface 4 x retime & VCSEL driver 4 x PIN receive amp & retime 4 fiber MMF 4 fiber MMF QSFP28 MPO optical connector Generation 2 100GBASE-SR4 25G / lane 7

QSFP28 Client Device IEEE 802.3bm considered retimer-less interface for 20m (resulting in ~1.5w QSFP28), but rejected. 100m MMF requires retimer. 20m market was too small to develop independent interface type from 100m. Might be used in future very short reach applications. Proprietary Active Optical Cable interfaces adopted QSFP28 / 1.5w form factor. 4 x 25G Analog 4 x Driver 4 x Lim Amp 4 x VCSEL 4 x PIN Optical I/O ~1.5w QSFP28 Client Fujitsu Proprietary and Confidential 8

Package Trends 100GE Client Optics 1 st generation: CFP: for MMF and SMF (actual) 2 nd generation: CFP2, CPAK (actual) 3 rd generation: CFP4, QSFP28 (forecast, actual) CFP CFP2 CFP4 QSFP28 9

Some 400GE Adopted Objectives Some Initial Ideas Support a BER of better than or equal to 10-13 at the MAC/PLS service interface (or the frame loss ratio equivalent) Provide appropriate support for OTN Specify optional Energy Efficient Ethernet (EEE) capability for 400 Gb/s PHYs Provide physical layer specifications which support link distances of: At least 100 m over MMF At least 500 m over SMF At least 2 km over SMF At least 10 km over SMF 25G x 16 VCSEL looks promising for MMF Small package (CDFP?), new 16-position MMF MT/MP connector. Potential for very high density and lower cost. Several formats including 4λ-DMT and 8λ-PAM4 being studied for duplex SMF. 10

Form Factor Evolution 400GE Client Gen 1: CDP Client: 400GBASE-??? Ref: oif2012.346.02 Gen 2: CDP2 Client 400GBASE-??? 16 x 25G Digital Electrical I/O CDP CDP2 8 x 50G Digital Electrical I/O XAUI = 10GE XLAUI = 40GE CAUI = 100GE CDAUI = 400GE 16x25G electrical lanes 8x50G electrical lanes CDP4 4x100G electrical lanes?? Far Future: CDP4 Client: 400GBASE-??? Are electrical lanes practical at 100G? Note: originally called CDFP in the OIF presentation. Renamed to CDP. 11

CDFP MSA (for 400GE) March 10, 2014 MSA Rev 1.0 Provides 16 x 25G electrical interface. Optimized for 16-wide VCSEL based MMF. TIA concurrently working on standard for 2 x 16 MMF fiber ribbon and MTO/MTP MMF connector. Could be called 400GBASE-SR16 if IEEE standardized in 2017. Desire by some in IEEE to have a 4 x 100GBASE-SR4 breakout mode of operation. Card cage is small, but cage + plug in roughly the same size as 4 x QSFP28 12

1 Terabit Ethernet IEEE elected to work on 400GE as opposed to 1TE due to significant technical issues. Very small size, low power, low cost and high production volume are key requirements for intra-datacenter optics (TOR Ethernet switch interconnect). Extrapolating current technology: 40 channels x 25G VCSEL. Would require 40-wide MMF fiber ribbon x 2 (80 total fibers). Electrical interconnect to the package would be massive. Faster electrical signaling speeds and multi-level modulation may be possibilities. Not ready for the IEEE application. Proposals for DMT and PAM-4 technology for 400GE. 500m 10km duplex SMF. Future: Might form basis for 1TE Duplex SMF Ethernet client interconnect. 13

Coherent DWDM Packaging Network Optics DWDM Coherent 100G optics moving towards CFP2 form factor. Two approaches: Digital Interface to Optics Places DSP inside the optics package. Pros: well-quantified optical performance. Cons: DSP power consumption makes thermal issues extremely challenging. Analog Interface to Optics. DSP is outside the optics package. Pros: multivendor optical sourcing, low cost, thermal management fits CFP2 package well. CFP4 may become practical later. Cons: PC board layout and DSP placement may impact optical span performance in strong or weak ways (unknown at this time). 14

CFP2 Analog DWDM Coherent Module CFP2 Optical Package DSP ASIC 4 x Driver Laser DP-QPSK Modulator + PBC Local Osc 4 x TIA PBS + Coherent Quad Combiner + 8 x PIN DWDM Coherent Optical I/O 4 x ~32G Analog Analog interface and copper traces between DSP and CFP2 optics will impact the span reach and optical performance. Skew, reflection, attenuation, crosstalk. Quantification of the impact requires actual DSP, PC Board, and optical CFP2 modules, and characterization. Fujitsu Proprietary and Confidential 15

CFP2 Digital DWDM Coherent Module CFP Optical Package CAUI-4 Interface DSP ASIC 4 x Driver Laser DP-QPSK Modulator + PBC Local Osc 4 x TIA PBS + Coherent Quad Combiner + 8 x PIN DWDM Coherent Optical I/O Standard CAUI-4 interface and copper traces between Host and Module. Optical span performance not dependent on host. CFP package currently required due to high power dissipation. Fujitsu Proprietary and Confidential 16

Analog CFP2 Issues Digital CFP Issues Interface to Analog CFP2 DWDM Coherent transceiver. DSP is external to the optics package. Copper traces connect analog I/O from DSP to Optics. Signaling rate is about 32 Gbps. Digitizing rate of DSP ADC is about 64 Gsps. Future generations (class 2, 3) planned to additionally support 16QAM. Analog interface, DSP, copper traces, optical module all have an impact on the optical span performance. Too early to tell how tightly constrained the optical performance will be. Performance may be weakly or strongly impacted by PCB motherboard, DSP, copper traces, and/or optics module changes. Might be addressable with conservative design rules. Might be addressable by complete chain characterization (but this can get complex). Optics + DSP + PCB motherboard to determine performance. Digital module is large due to high power DSP inside optical envelope. Limited supply base for digital version. 17

Copyright 2010 FUJITSU LIMITED 18