Installation Manual. WKC Weigh Modules

Similar documents
Reference Guide METTLER TOLEDO WMH Weighing Platforms

Automated Precision Weighing

Installation Manual. SLP85xD Load cells

Inclinometer. 4-20mA and RS232

Installation Manual. Weigh Modules WMS/WMS Ex Zone 2

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

GSV-1A4 M12/2 M12/2. Highlights

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Absolute encoders - bus interfaces

Installation Manual. Weigh Modules WXS/WXT

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485

TCNM-ACBB1 Installation Manual

Technical data. General specifications. Indicators/operating means

LVX Control Unit. Features:

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Absolute Encoders Multiturn

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Operating Instructions. Modules Fieldbus

EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Light Curtains. Type 4 SG4. Type 4 SG4 Series. 468

English. User Manual Precision and Analytical Balances ML-T

INDUSTRIAL INCLINOMETER ANALOG & RS232 INTERFACE

FIT 7A. Digital load cell dynamic weighing. Special features. Data sheet

Multiturn absolute encoder

Weigh Modules. Maximum Precision for Automation Fast, Flexible, Easy to Integrate

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg.

Absolute encoders - SSI

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

Operating Instructions. Controller for Automatic Mass Comparators from Software Version 1.22 for CC...- L / CCE...- L Model

PHOENIX CONTACT - 05/2007

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8395A...

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Note: the wiring of the dead-man buttons has been changed since October 2001.

Operating Instructions. Modules Fieldbus

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8396A...

MGate 4101-MB-PBS Series

IT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Manual Industry Interfaces

IPC194. ipconv Protocol Converter

Quick Guide. bpro Retail scale

Operating instructions METTLER TOLEDO BD balances

General Operating, Maintenance and Installation Manual

Product Information ECN 1324S EQN 1336S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

M2-iLAN-2 Laser Scanner

HMG 11. Features. Optional Additional incremental output (TTL / HTL) HMG 11. Technical data - mechanical design. Technical data - electrical ratings

Sartorius Comparator. Interface Description for the CC Model Series

Linear Position Transducer HLT 1000-R2

MobileView Junction Box

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00

Thread length (overall length) material

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

Assembly Instructions scancontrol 2700/2750 (500)

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Operating Instructions

SCB-C08 USB to RS232/422/485 Converter

User Manual. Printer P-52RUE

Absolute Encoder Multiturn

PRELIMINARY EAMH 58 B / C - 63 A / D / E BIT PARALLEL - SSI SOLID SHAFT MULTITURN ABSOLUTE ENCODER ORDERING CODE BIT PARALLEL

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

1.1 Functional Description: NO Switch Functional Description: Illumination TECHNICAL DATA AND DIMENSIONAL DRAWINGS...

Component identification

QUINT-BUFFER/24DC/24DC/40

Distance and Position Sensors

PCI Express 4-Port Industrial Serial I/O Cards

Manual Swipe Magnetic Card Reader

USB-COM Plus ISO (USB-COMi SI-M)

Operating instructions. METTLER TOLEDO Bidirectional Data Interface for the J series balances. Option 018

Integrated in the motor Mounting via spread shaft Mounting via plug-in shaft Mounting via hollow shaft Mounting via coupling and solid shaft

FL MC 2000E (SM40) LC

TM221CE40R controller M IO relay Ethernet

Installation instructions Ethernet switch EC / / 2011

AMG 11. Features. Optional. Additional incremental output (TTL / HTL) AMG 11. Technical data - mechanical design. Technical data - electrical ratings

Display Panel BAT 100 LSN. en Operation Guide

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

Digital electropneumatic positioner

Modular controllers CECX

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

HEAVY DUTY INCLINOMETER ANALOG & RS232 INTERFACE

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

standard, short, preferential, top

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Transcription:

Installation Manual Weigh Modules

Table of Contents 1 Installation 3 1.1 Mechanical installation... 3 1.1.1 Support Interface (Support Surface)... 3 1.1.2 Weighing Interface (Weighing Platform)... 3 1.2 Electrical Installation... 5 1.2.1 Typical Configuration... 5 1.2.2 Power Supply... 6 1.2.3 Cables and Wiring... 6 1.3 Pin Assignment of the M12 Connector... 6 1.4 ConBlock / ConBlock IP66 connection safe area... 7 2 Configuration 8 2.1 Communication Protocol... 8 2.2 Checklist for Configuration... 8 2.3 PC Configuration... 9 3 Operation 10 3.1 Operation Limits... 10 3.2 Applying / Removing the Weighing Object... 10 3.3 Transmission of Weight Values... 10 3.4 Tare Function... 11 3.5 Reset (Zero) Function... 11 4 Technical Data 12 4.1 General Data... 12 4.2 Interface Specifications... 13 4.3 Type Designation Code... 14 4.4 Dimensions... 15 4.5 Accessories... 17 Table of Contents 1

2 Table of Contents

1 Installation 1.1 Mechanical installation 1.1.1 Support Interface (Support Surface) Observe the following when designing the support interface for the weigh module: Wherever possible, provide a vibration-free support surface for the weigh module. The maximum permissible slope (angle from horizontal) of 0.5 % must not be exceeded. Determine the floor properties in the location where the system is to be set up. Make sure that no building oscillations are transferred to the support surface via the floor The support surface has to be stiff because a stable mechanical base is mandatory for precise and fast weighing results. The support surface must be absolutely level to prevent the base plate from twisting. Take care that no vibrations are transmitted via the connecting cable. Important: Avoid temperature influences over the support surface to the weigh module. Mounting the weigh module on the support surface Use the 4 mounting holes (1) (Ø 5.5 mm) at the bottom plate to fasten the weigh module to the support surface. 1 1.1.2 Weighing Interface (Weighing Platform) When building a custom weighing platform, the following needs to be considered in order to achieve the best weighing performance. Material of the Weighing Platform The material has to be selected from electrically conductive material in order to prevent the accumulation of electrostatic charges. Weight and stiffness Light and stiff weighing platforms are less susceptible to vibrations. The preload range of the weigh module is limited to the weight of the adapter weighing pan. Custom weighing platforms which are built on the top of the adapter weighing pan will reduce the weighing range of the weigh module by their weight. Eccentricity A custom weighing platform has to be designed so that the center of gravity of the weighing platform lies at the primary loading axis or as close as possible. The primary loading axis goes through the center point of the adapter weighing pan (1). 1 Installation 3

Overload protection limits B A D B C D Please take are of the overload protection limits specified in the table below. The weigh module can be damaged if these limits are exceeded. Weigh module A Max. compression B Max. lateral force C Max. uplift force D Max. rotating torque 204 4 kg 1.5 N 15 N 1 Nm 603 6 kg 2 N 20 N 1.3 Nm 6002 20 kg 20 N 50 N 3 Nm Mounting the weighing platform 1 Take off the adapter weighing pan (2) from the load receiver. 3 3 2 Use the 4 M3 threaded mounting holes (3) to fasten the custom weighing platform onto the adapter weighing pan when there is no contact to the load receiver. 2 3 Put the weighing interface consisting of custom weighing platform and adapter weighing pan on the load receiver (black plastic adapter). Important Only mount the custom weighing pan to the adapter weighing pan when there is no contact to the load receiver. Otherwise the load cell can be damaged due to overload forces during installation. 4 Installation

1.2 Electrical Installation 1.2.1 Typical Configuration weighing modules can be connected to the control system via the standard M12 cable (12 pins). The terminal strip called "ConBlock" which is provided by METTLER TOLEDO as an accessory can be used to facilitate the wiring. 10 7 9 8 6 5 1 4 2 3 Pos. Item Dexcription Item number 1 weigh module Various models available, weighing platform included 2 Connection cable M12 female molded cable connector 12 pins, shielded right angled, free cable end Cable length: 1.5 / 5 m Cable jacket: PUR/PVC 3 ConBlock Terminal block with dedicated service interface 4 Subnet cable To connect the weigh module to a fieldbus module: D-Sub 9 male < > open ends 5 Fieldbus module Various models available, incl. connection cable for configuration See order information See [Accessories } Page 17] 6 Customer cable Fieldbus cable 3 rd party item 7 PLC Control system 8 Customer cable For communication with PLC via RS232 or RS422 interface (recommended) 9 RS232 cable Customer interface for configuration and service 10 PC or laptop For configuration and service Installation 5

1.2.2 Power Supply weigh modules work with 12 to 24 V DC nominal (10 to 29 V DC), input current: 0.84 A 1 Use a stable power supply with no voltage fluctuations. 2 If voltage fluctuations cannot be prevented, use a voltage regulator to deliver a constant voltage value to the weigh module. 3 The power supply must be approved by the respective national test center of the country in which the weigh module will be used. 1.2.3 Cables and Wiring METTLER TOLEDO recommends using standard cables and advises against tailoring cables to extend the cable range. Electromagnetic behavior and the reliability of the data communication are only tested for standard cables. Therefore, no guarantee can be given for longer tailor-made cables. However, if it is inevitable to build a tailor-made cable, a shielded cable must be used to prevent faults in the data transmission and/or weighing results. The shield must be connected to the connector housing on one side and to the system ground on the other side to avoid ground loops. The best grounding scheme may only be determined by trial and error on site. It is important to observe the maximum allowable cable length of the physical transmission medium. Long transmission cables should be isolated against electro-magnetic interference by using shielded cables and twisted pairs. Data cables should be separated and isolated from power lines. Wiring must be correct before powering up the load cell. Confusing the power pins with data pins might damage the load cell. Wires should not be plugged in or unplugged while power is applied to the load cell. 1.3 Pin Assignment of the M12 Connector Connector M12 Pin Signal Cable color * P1 20 1 V DC (Power, 12 V DC) White 2 GND (Ground) Brown 3 RS422 GND (Ground) Green 13.4 4 TXD (RS232) Yellow 8 9 7 6 5 4 12 11 3 10 1 2 5 RTS (RS232 Gray 6 RXD (RS232) Pink 7 CTS (RS232 Blue 8 GND (RS232) Red 9 TX+ (RS422) / B+ (RS485) Orange 10 TX (RS422) / A (RS485) Purple 11 RX+ (RS422) / B+ (RS485) Black 12 RX (RS422) / A (RS485) Violet Shield Braid * Cable color of the METTLER TOLEDO standard cables. RS422 / RS485 configuration The RS422 interface is directly available via the connection terminals. For the RS485 configuration, the following signals must be connected: A : Tx and Rx B+: Tx+ and Rx+ 6 Installation

1.4 ConBlock / ConBlock IP66 connection safe area ConBlock provides the following terminals: System connection side: 10 terminals Weighing platform connection side: 2 x 10 terminals RS232 interface (DSub 9) for configuration and servicing ConBlock connections weighing platform side The weigh module is delivered with a 12 wire open end cable. The corresponding terminals of the ConBlock are identified by the wire color and the respective pin designation: Pin J D H T F K G E A O Color White Brown and green Signal V DC GND Pin L U P C R B S N M Shield Color Orange Black Purple Violet Blue Red Grey Pink Yellow Braid Signal TX+ RX+ TX RX CTS GND INT ConBlock connections system side RTS RXD TXD Shield The connection terminal strip is grouped according to the following functions: RS232 and RS422/RS485 interfaces, input voltages and digital inputs and outputs RS232 RS422 (in) RS422 (through) Power RXD RTS RX+ TX+ RX+ TX+ V DC TXD CTS RX TX RX TX GND GND INT Shield Shield Shield PE Installation 7

2 Configuration 2.1 Communication Protocol weigh modules make use of the MT-SICS communication protocol in order to communicate with control systems. The MT-SICS protocol is defined by METTLER TOLEDO. MT-SICS stands for METTLER TOLEDO Standard Interface Command Set. MT-SICS is an ASCII-based communication protocol with string-type data format. Each string includes 8 data bits representing the letter or digit, and one stop bit. For more information refer to the Reference Manual for MT-SICS Interface Commands, 11781363 (English). This can be downloaded from Documentation 2.2 Checklist for Configuration Before configuring the weigh module, clarify the following points: What sort of weighing process is involved (control weighing or filling to a target weight)? What level of precision must be achieved (expressed in grams)? What level of repeatability is required (expressed in grams)? What weighing rate is required? How heavy is the load supporting device (preload)? Which external weight will be used for checking/adjustment? u http://www.mt.com/ What sort of interference might be present in the environment (vibrations, air draft, electrostatics)? How will the weighing object be applied? To which PLC interface will your system be connected? 8 Configuration

2.3 PC Configuration weigh modules can be configured with MT-SICS commands. For this configuration, the weigh module must be connected to a PC or laptop. In order to configure parameters of the weigh module by a PC or laptop, the following items are needed: Hardware requirements weigh module M12 connection cable RS232 cable with USB converter (if needed) PC or laptop with Windows operating system Software requirements: APW-Link APW-Link software version V2.3 or higher, to configure the weigh module with MT-SICS commands The APW-Link can be downloaded from the following link: Download link u http://www.mt.com/apw-link Following aspects of the weigh module and many more parameters can be configured with APW-Link : Stability criteria (USTB command) Filter properties (M01 command) Filter damping (M02 and FCUT commands) External and internal adjustment and test (C2, TST2, C3, TST3, C7, C8 commands) Update rate for continuous weight transmission (UPD command) For more information refer to the Reference Manual for MT-SICS Interface Commands, 11781363 (English). This can be downloaded from Documentation u http://www.mt.com/ Configuration 9

3 Operation 3.1 Operation Limits When operating weigh modules, the following operation limits have to be observed: The maximum permissible load on the weigh module is defined by the maximum capacity specification of the weigh module (see User Manual). This range includes the custom weighing platform (preload) plus the weighed object and the container. For environmental conditions see User Manual. The specified metrological performance of the weigh module is ensured for the compensated temperature range ( 10... 30 C). 3.2 Applying / Removing the Weighing Object When applying or removing the weighing object on / from the weighing platform, observe the following important rules: Excessive additional forces or vibrations affecting the weighing platform as a result of applying or removing the weighing object can impair the weighing duration and the result. Make sure that you keep additional forces and vibrations to a minimum when applying or removing the weighing object. Lateral impacts should be avoided. The weighing object should come to rest on the weighing platform as quickly as possible once it has been applied. If the weighing object is pushed sideways onto the weighing platform by a feed mechanism, a certain height difference between the weighing platform and the loading/unloading arm should be ensured. The weighing pan should be lower than the loading level and higher than the unloading level. Make sure that the object or its center of gravity is as close to the center of the weighing platform as possible during weighing or that it is always applied in the same way. It is not recommended to move the weigh module toward the weighing object. This kind of setups can cause shock overloads inside the weigh module due to the dynamic movement in a short time. Shock overloads are always difficult for the weigh module to handle and might lead to failure over the long term. 3.3 Transmission of Weight Values The weight values that are transmitted relate either to the zero point or to the point derived from the tare command, depending on whether the previous function executed was a reset to zero or taring. Commands that are normally only completed when a stability criterion is met respond with an abort if the stability has not been achieved within the defined time limit (Timeout, command M67). The following MT-SICS commands can be used to request weight results form the weigh module: MT-SICS command S SI SIR SNR SR Descripiton Transmit stable weight value Transmit weight value immediately (stable, not stable) Transmit weight value immediately and repeat (stable, not stable) Transmit next stable weight value and repeat Transmit weight value and repeat when the weight changes For more information refer to the Reference Manual for MT-SICS Interface Commands, 11781363 (English). This can be downloaded from Documentation u http://www.mt.com/ 10 Operation

3.4 Tare Function In taring the weight value that relates to the current zero point is regarded as the tare weight and is transferred to the tare memory. At the same time, the current displayed weight value is reset to zero. The following MT-SICS commands can be used to execute the tare function: MT-SICS command T TA TAC TI Note Descripiton Adopt current stable weight value as tare weight Set / query tare weight Delete tare weight Adopt weight value as tare weight immediately The taring functions cannot be executed if the current weight value is negative relative to the current zero point. For more information refer to the Reference Manual for MT-SICS Interface Commands, 11781363 (English). This can be downloaded from Documentation 3.5 Reset (Zero) Function u http://www.mt.com/ The reset function defines a new zero point (reference point), the current weight value is reset to zero and the tare memory is cleared. Depending on the configuration, the reset is performed automatically whenever the module is switched on or the stored value is used. The following MT-SICS commands can be used to execute the reset (zero) function: MT-SICS command Z ZI Note Descripiton Adopt current stable weight value as zero point Adopt the current weight value as the zero point immediately For more information refer to the Reference Manual for MT-SICS Interface Commands, 11781363 (English). This can be downloaded from Documentation u http://www.mt.com/ Operation 11

4 Technical Data 4.1 General Data Dimensions Weigh module (L x W x H) Interfaces Interface type Interface update rate Connector Power supply Power supply voltage Input current Materials 245 x 112 x 90.5 (6002C) 245 x 112 x 82 (204C / 603C) RS422, bidirectional, full duplex, 2'400 to 38'400 bps RS485, unidirectional, half duplex, 2'400 to 38'400 bps RS232C, bidirectional, full duplex, 2'400 to 38'400 bps max. 92 Hz M12, 12 pin, male, A-coded 12 to 24 V DC nominal (10 to 29 V DC) 0.84 A Housing, base plate Stainless steel (EN 1.4307 / 304) Weighing pan Stainless steel (EN 1.4307 / 304) Seal between baseplate and housing Surface roughness of housing Ambient conditions NBR 60 Shore A, black, 1000 Ohms N7 (Ra1.6) or better Operating temperature +10 to +30 C Allowable ambient temperature +5 to +40 C Storage temperature 25 C to +70 C Relative humidity Max. height above sea level Warm-up time Max. 80 % at 31 C, decreasing linearly to 50 % at 40 C, non-condensing 4,000 m ( 13,330 ft) At least 30 minutes after power up IP protection (in operational state with weighing platform in place) When weighing IP42 12 Technical Data

4.2 Interface Specifications For the pin assignment see [Pin Assignment of the M12 Connector } Page 6]. RS422/RS485 interface Parameter Interface type Max. cable length Signal level Type of operation Type of transmission Transmission code RS422/RS485 Voltage-controlled interface in accordance with EIA RS422 and EIA RS485 standards (CCITT V.11, DIN 66259 Part 3)) 1200 m Outputs: ±6 V Inputs: ±3 V RS422: full duplex RS485: half duplex bit serial, asynchronous ASCII Baud rates 2'400 to 38'400 Bits/parity Stop bits Handshake Line break 7 Bit/Even, 7 Bit/Odd, 7 Bit/None, 8 Bit/None 1 stop bit Non, XON/XOFF, RTS/CTS <CR><LF> RS232 interface (service interface) Parameter RS232C Interface type Voltage-controlled interface in accordance with EIA RS-232C / DIN 66020 standard(ccitt V.24/V.28) Max. cable length Signal level Type of operation Type of transmission Transmission code 15 m Outputs +5 V... +15 V (R L = 3... 7 kohms) 5 V... 15 V (R L = 3... 7 kohms) full duplex bit serial, asynchronous ASCII Baud rates 2'400 to 38'400 Bits/parity Stop bits Handshake Line break 7 Bit/Even, 7 Bit/Odd, 7 Bit/None, 8 Bit/None 1 stop bit Non, XON/XOFF, RTS/CTS <CR><LF> Inputs +3 V... 25 V 3 V... 25 V Technical Data 13

4.3 Type Designation Code Your weigh module is uniquely identified by the type designation. The type designation can be found on the laser label on your weigh module. 1 C 2 # Designation Values W Weigh K Kit C Compact 1 Capacity and readability 204: 220 g / 0.1 mg 2 Internal adjustment feature C 603: 620 g / 1 mg 6002: 6200 g / 10 mg 14 Technical Data

4.4 Dimensions 204C and 603C Round weighing pan 130.5 82 ±0.5 112 110 ±0.1 59.5 82 45 18 Ø37 Ø5.5 (4x) 11.5 222 6 245 233 ±0.1 Square weighing pan 130.5 82 ±0.5 112 110 ±0.1 59.5 82 45 18 40 34 M3 (4x) Ø5.5 (4x) 11.5 222 6 245 233 ±0.1 Technical Data 15

6002C Round weighing pan 124 90.5 ±0.5 67.5 45 Ø37 112 110 82 ±0.1 18 Ø5.5 (4x) 11.5 6 222 233 ±0.1 245 Square weighing pan 124 90.5 ±0.5 67.5 45 40 34 M3 (4x) 112 110 82 ±0.1 18 Ø5.5 (4x) 11.5 6 222 233 ±0.1 245 16 Technical Data

4.5 Accessories Item Order number Round weighing pan, without threaded holes 30 265 396 Square weighing pan, with threaded holes 30 315 518 Connection cable, 1.5 m 30 295 819 Connection cable, 5 m 30 295 821 ConBlock 11 152 000 Subnet cable 11 141 979 Profibus module 42 102 809 Profinet module 42 102 859 DeviceNet module 42 102 810 Ethernet IP module 42 102 860 CC-Link module 30 038 775 Weight 100 g E2 30 315 527 Weight 200 g E2 30 315 528 Weight 500 g E2 30 315 529 Weight 1 kg E2 30 315 530 Technical Data 17

18 Technical Data

www.mt.com For more information Mettler-Toledo GmbH Industrial 8606 Nänikon, Switzerland www.mt.com Subject to technical changes. Mettler-Toledo GmbH 09/2017 30297212C en 30297212