MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM

Similar documents
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM

SPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS VEHICLE DETECTION SYSTEM. SIG:EMS 1 of 6 APPR:MDW:DBP: FHWA:APPR:

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR TRAVEL TIME SYSTEM. UNIV:SRP 1 of 6 ITS:APPR:CLC:DBP:

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MULTI-SENSOR (VIDEO AND RADAR) VEHICLE DETECTION SYSTEM

SPECIAL SPECIFICATION 1303 Lifelink

SPECIAL SPECIFICATION 8506 Radar Advance Detection Devices

SPECIAL SPECIFICATION 8939 Retrofit Existing Fiber Optic Dynamic Message Sign System to LED

SPECIAL SPECIFICATION 7443 Radar Vehicle Sensing Device (RVSD) System Maintenance

SPECIAL SPECIFICATION 8143 Wireless Ethernet Radio System

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR ACCESSIBLE PEDESTRIAN SIGNAL SYSTEM

SPECIAL SPECIFICATION 6230 Fiber Optic RS-232 Data Modem

SPECIAL SPECIFICATION 8885 Wireless Ethernet Radio (Backhaul) Link

SPECIAL SPECIFICATION 6838 Wireless Ethernet Microwave Radio

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

RICHMOND SIGNAL SYSTEM - JAHNKE AND FOREST VIEW SCHOOL DRIVE SPECIAL PROVISIONS FOR THERMAL VEHICLE DETECTION

SPECIAL SPECIFICATION 8371 Field Terminal Server

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

TECHNICAL SPECIAL PROVISION FOR. ITS Automatic Vehicle Identification System (AVI): Financial Project ID:

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

SPECIAL SPECIFICATION 6027 Lane Control Signal Equipment

SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem

SPECIAL SPECIFICATION 6373 Wireless Radio Traffic Management Sites

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SPECIAL SPECIFICATION 6325 Wireless Ethernet Microwave Radio

C-POWER AC AUTOMATIC CONTROL

Governing Standards. All wiring and components shall meet the applicable requirements of the NEC.

SECTION PANELBOARDS

Level-Lance Model 5400A

ROAD COMMISSION FOR OAKLAND COUNTY SPECIAL PROVISION FOR VIDEO SURVEILLANCE MANAGEMENT SYSTEM (VSMS) SOFTWARE

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

SPECIAL SPECIFICATION 1826 Field Ethernet Switch

Emery County Senior Center Green River 06/07

TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT

ITS DEVICE INTEGRATION AND TESTING

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SYSTEM INTEGRATION AND TESTING. ITS:CLC 1 of 19 APPR:JVG:DBP: FHWA:APPR:

SPECIAL SPECIFICATION 6475 CCTV Field Equipment

SPECIAL SPECIFICATION 1816 Traffic Data Collection Subsystem

SmartSensor 105. Installation Guide

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Houston Radar SpeedLane Pro Quick Start Guide

SPECIAL SPECIFICATION 1861 Premium Subrate Data Multiplexer and Distribution Panel

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Addendum # 2. Bid # Scoreboards (Softball Baseball Soccer) Addition Specification on Softball and Baseball

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

iconverter 2-Module Power Chassis

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

1510 MOTOR CONTROLLERS

MODIFIED SPECIAL PROVISION APPROVAL REQUEST (REV ) Date: 11/02/2015 District: 5 Type: Project Specific

VADDIO /CANON BU-SERIES PTZ CAMERAS

Back-UPS RS APC Back-UPS RS 800VA 120V Black

RTMS G4 User Manual. RTMS G4 User Manual Version 5.5 Nov, 2011 PN C

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

Houston Radar SpeedLane Quick Start Guide

OVP2. The Over-Voltage Protector 2 (OVP2) Technical Literature

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)

A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

SPECIAL SPECIFICATION 1252 System Control Unit Console

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console

MODEL 8000MP LEVEL SENSOR

AP-Ext-N User Manual

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM 6392 CCTV FIELD EQUIPMENT

XBR V4 INSTALLATION AND USER GUIDE

MAINTENANCE / INSTALL & TROUBLESHOOT GUIDE FOR MVDS

SPECIAL SPECIFICATION 6287 CCTV Field Equipment

SECTION SURGE PROTECTIVE DEVICES

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System

ROAM Decorative Node Control Specification Guideline Division 16520

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

Surg Sur e P ot r ection

Generic Procurement Specification for a Video Detection Solution for Roadway Applications

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Proven Industrial Reliability for Mission-critical Communications

Project Documentation TMIB Data Sheet

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)

SPECIAL SPECIFICATION 6518 IP Video Codec

SECTION ( ) LIGHTING CONTROL PANELBOARD

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

SPECIAL SPECIFICATION 1986 CCTV Field Equipment

Basketball Shot Clock Set LX2180 Manual

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SYSTEM INTEGRATION AND TESTING. ITS:CLC 1 of 22 APPR:MDW:JVG: FHWA:APPR:

CLIPLINE complete. The modular terminal block system for all applications

FLEX Ex Spring Clamp Terminal Base

Transcription:

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM ITS:CLC 1 of 5 APPR:JVG:DBP:06-29-17 FHWA:APPR:08-02-17 a. Description. This work consists of one or more of the following: 1. Furnish, install, integrate, and test a Microwave Vehicle Detection System (MVDS). The MVDS is a noninvasive detection system installed above ground on the side of the road (i.e., side-fire). Its express purpose is vehicle detection and reporting of specified data by way of the ITS communication network to the designated Advanced Traffic Management System (ATMS) software. The MVDS consists of a radar detection unit pole-mount assembly; mounting hardware; UL approved power supply; lightning and surge protection; all required cable; and communications patch cords. 2. Remove and salvage a MVDS and all required mounting hardware, power supply, cables, patch cords and jumpers. 3. Install a salvaged MVDS and all required mounting hardware, power supply, cables, patch cords and jumpers. b. Materials. 1. Functional Specifications. A. Provide a complete side-fire mounted MVDS. The equipment includes, but is not limited to, a microwave detection unit (sensor within a weatherproof housing), i.e. the detector; composite cable required to connect the microwave detection unit to the power source and the ITS network; various control and communications equipment to be contained within an ITS equipment cabinet (cabinet paid for under a separate special provision); an Ethernet adapter appliance (if required); mounting brackets; and all ancillary equipment and/or incidental items as required to make a complete and fully operational detection system. B. Ensure the detection process utilizes a microwave signal to accurately detect and measure vehicle classification, vehicle volume, speed, true presence (including stopped vehicles), and occupancy in all weather conditions without performance degradation. C. Ensure the design the microwave circuitry within the MVDS utilizes active control that dynamically adjusts to compensate for temperature and aging variations in component performance. D. No field calibration or adjustment after the initial setup is allowed. If calibration or adjustment is required after initial setup, the particular MVDS will be considered defective and must be replaced at no additional cost to the Department.

ITS:CLC 2 of 5 06-29-17 E. Ensure the MVDS unit supports Point-to-Point Protocol (PPP) and Point-to-Multi- Point Protocol (PMPP) via Ethernet communications either by a MVDS internal Ethernet port or vendor-supplied external terminal server and vendor-supplied Ethernet appliances. The MVDS is to be addressable and capable of downloading detection data when polled by the ATMS software. F. Provide a detector capable of switching between data pushing and data polling. G. All traffic measurements or traffic parameter data defined on the plans are to be stored in nonvolatile memory within the MVDS detector. Ensure the MVDS is capable of transferring this traffic parameter data from the detector s nonvolatile memory to the ATMS software by way of a local managed field Ethernet switch (MFES) and ITS communications network. 2. Performance Specifications. Required minimum performance of the MVDS: A. Detection of vehicles in multiple discreet lanes within the detection zone of up to 12 discreet lanes and in both directions providing accurate, real-time presence, volume, average speed and occupancy data. Ensure detections are correctly categorized into 3 length-based classifications. Vehicle detection must occur at a range of 10 feet to 250 feet from the MVDS. B. The reporting of classification, presence, volume, occupancy and speed data for each discreet lane of the 12 travel lane detection zones. C. Accuracy Required. Volume (±5 percent); average speed (±10 percent); occupancy (±10 percent). 3. MVDS Housing and Mounting Hardware Specifications. A. Accomplish connectivity of the MVDS detection unit to external equipment by a composite cable and a single connector. The connector/cable must provide power to the unit and communications into the ITS cabinet. B. Mount the MVDS detection device in a polycarbonate box meeting NEMA 250 Type 4X Enclosure requirements with the electrical connection located at the bottom of the box. C. Provide a universal mounting bracket capable of pole- or wall-mounting of the MVDS. The universal mounting bracket is required to be adjustable on two axes. D. Stainless steel bands with a minimum width of 0.75 inch and 0.025 inch thickness are required to strap the universal mounting bracket to a pole. For wall/bridge mounting, 2 stainless steel expansion bolts with sufficient length and diameter to support a minimum of 40 pounds are required. 4. Power, Communications, and Cable Specifications. A. All power and communications cables are to be a polyurethane-jacketed cable, Belden #9516, outdoor rated Category 5e (CAT-5e), outdoor rated Category 6 (CAT-6),

ITS:CLC 3 of 5 06-29-17 or an approved equal. This cable s minimum rating is 300 volts (V) with a minimum temperature rating of 140 degrees Fahrenheit (F). B. Conductor size. American Wire Gauge (AWG) #24 or larger conductors, as recommended by the MVDS manufacturer. 5. Electrical Specifications. A. The MVDS is to consume no more than 8 watts with a direct current (DC) input between 12 and 24V DC. Automatic recovery from power failure within 15 seconds after resumption of power is required. B. Federal Communications Commission (FCC) certification of the detector is required. Ensure the FCC s identification number is displayed on an external label. Transmission frequency band of 24.125 gigahertz (GHz), using the K band, or another approved spectral band is required. Compliance with 47 CFR Part 15 is required. C. Internal lightning suppression and electrical isolation is required. 6. Environmental Specifications. A. All materials are required to be corrosion resistant and approved by the Engineer. B. Ensure the MVDS s operation is not affected by a minimum vibration of 16.087 feet per second squared (ft/s 2 ) at 30 Hertz and a shock ratio of 160.87 ft/s 2 for 10 millisecond half sine waves. C. Ensure the MVDS has an operational temperature range of -29.2 degrees F to 165 degrees F, without performance variation. D. All system components, while housed in their associated environmental enclosures, are to comply with NEMA TS-2 environmental specifications. Ensure the housing is capable of wind loads of up to 120 miles per hour (MPH) sustained. c. Construction. 1. General Requirements. A. Prior to submitting shop drawings, a pre-construction site survey is to be conducted by a factory-trained and certified representative. The site survey is designed to identify the exact location and details for each detection station. The site survey report is to be submitted to the Engineer for approval, including specific location and detail information. B. Mount detection units in a side-fired configuration. Mount the detector level from side to side. Furnish a laptop computer and software to be used for zone calibration. Detector height and downward pitch angle are to be in accordance with the manufacturer recommendations for the roadway, median width, and number of lanes being detected at each site. C. All detection zones are to be contained within the specified elevation angle as suggested by the manufacturer.

ITS:CLC 4 of 5 06-29-17 D. When installing the detector near metal structures, such as buildings, bridges, or sign supports, mount and aim the detector so the detection zone is not under and does not pass through the structure to avoid distortion and reflection. E. All wires are to be cut to their proper length before assembly. No doubled-back wire/cable to take up slack is allowed. 2. Required Documentation. A. Submit shop drawings that detail the complete detector and all other components to be supplied and constructed to the Engineer for approval. Ensure these drawings detail the exact location and placement of system components and include installation details for the required cables. Install all cabling in accordance with manufacturer recommendations. B. Provide a training and maintenance manual for the MVDS, including detailed specifications and information regarding the inventory of installed assemblies by location and corresponding serial number. 3. Testing. A. Acceptance Test Plan (ATP). Develop and submit to the Engineer for approval an ATP as detailed in the 12SP-826I - System Integration and Testing. B. Detector Test. (1) Provide a radar gun for the verification and calibration of speed detection. Follow manufacturer recommended procedures for calibration. (2) Each installed MVDS s volume counts and speed measurements are to be verified utilizing the MVDS vendor-supplied test software running on a laptop connected locally to the detector communication port. Compare the counts from the detector to visual counts or counts from permanent or temporary traffic detection devices of known accuracy. Compare the speed measured by the detector to the speeds measured by the radar gun. Confirm that the accuracy is within the range required by this special provision. 4. Warranty. Provide MVDS with a standard manufacturer s warranty, transferable to MDOT. The MVDS must carry a warranty (parts, software and labor) of 2 years from the date of shipment with at least 1 year of warranty remaining at the start of burn-in. Furnish warranty and other applicable documents from the manufacturer, and a copy of the invoice showing the date of shipment, to the Engineer prior to final written acceptance. 5. Remove and Salvage. If MVDS remove and salvage is specified in the contract, the following procedures apply: A. Do not damage the ITS cabinet or associated equipment;

ITS:CLC 5 of 5 06-29-17 B. Remove the MVDS, mounting hardware, power supply, and power cabling associated with the MVDS. Disconnect all communication cables from the MVDS and leave them in place unless otherwise directed by the Engineer; C. Notify the Transportation Operations Center (TOC) and the Engineer a minimum of 7 days in advance of the decommissioning of the MVDS hardware; D. Salvage the MVDS, including mounting hardware, power supply, surge protectors (if any) and cabling, as directed by the Engineer. The salvaged equipment is to be stored at a location free of moisture, and rodent/insect intrusion. If the MVDS is to be reinstalled it must be stored until then, otherwise notify the Engineer once the equipment has been salvaged for pickup to be arranged. 6. Install Salvaged. If a salvaged MVDS is to be installed at a location specified in the contract, follow the procedures detailed in section c of this special provision. d. Measurement and Payment. The completed work, as described, will be measured and paid for at the contract unit price using the following pay items: Pay Item Pay Unit Microwave Vehicle Detection System... Each Microwave Vehicle Detection System, Rem and Salv... Each Microwave Vehicle Detection System, Install Salv... Each Microwave Vehicle Detection System consists of a radar detection unit pole or truss mount assembly, pole or truss mounting hardware, UL approved power supply, lightning and surge protection, all required cable, communications patch cords, and any and all ancillary items required for a fully operational MVDS remote site installation.