VersaMax IP Input Module

Similar documents
VersaMax IP I/O Module

GFK-2415A March Type of sensor connection

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

VersaPoint I/O Module

IB IL 24 DI 16 IB IL 24 DI 16-PAC

VersaMax IP. Proficy Machine Edition. Publication Reference Chart

IBS IL 24 BK RB-T-2MBD

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

IBS ST (ZF) 24 BK LB-T

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

This data sheet is only valid in association with the IL SYS INST UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

GE Intelligent Platforms. Programmable Control Products. VersaMax* IP. Installation Manual, GFK-2307B

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

AXL E IOL AO1 U M12 R

Diagnostics (Logical) Diagnostics (Physical)

PAC BI-DP BIM and 8701-CA-BI Carrier

AXL E PB DIO16 M12 6P

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

Copyright: December 2017 Nidec Issue: E

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

IBS IL 24 RB-LK-2MBD:

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

SK TU4-PBR Part number:

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

SK CU4-PBR-C Part number:

TURCK Modular Industrial I/O PROFIBUS -DP Products

PA ROUTERS. The following criteria can be applied when choosing the network transition:

Data sheet CPU 115 (115-6BL02)

Digital electropneumatic positioner

Fieldbus Direct Key features

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

SCHMIDT Sensor interface PROFIBUS Instructions for use

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

Digital electropneumatic positioner

User manual BLCDN-8M12LT-8XSG-PD-8XSGPD

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Diagnostics (Physical)

CAN 300 PRO, Communication Module

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE

Allen-Bradley Automation

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications

Data sheet CC 03, Commander Compact (603-1CC21)

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

Data sheet VIPA CPU 115DP (115-6BL22)

Device manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC / / 2013

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Profibus-DPV1 Set in IP20 TI-BL20-DPV1-2

Rotary Measurement Technology Absolute Encoders, Singleturn

ILC 200 IB ILC 200 IB-PAC

BNI PNT Z015. IP67 Modules 16 Input User s Guide

PAS 300, PROFIBUS Slave Interface Module

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804 Digital Input Module with Time Stamp EP-12F4

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

Serial PROFIBUS Interface

MPCR Series Profibus-DP Technical Manual

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

PROFIBUS Discrete I/O Modules

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

Product Information on the Manual

TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES. Pg. 1 di 14

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

SIMATIC S7-300 Product information for the S7-300 Automation System Manual, Module Data

Communication modules. Serial interface module

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP

IndraControl S67. Fieldbus coupler PROFINET

Manual and Protocol Description

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

EH-RIO IP67 Profibus-DP I/O modules

I / O Expander. Instrument for torque control ASL 11/17

SSI-1016H Specifications and Operation Manual

IB IL RS 232 IB IL RS 232-PAC

LVX Control Unit. Features:

Manual Fiber Optic Interfaces

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

Digital I/O modules. 8 inputs/outputs, M8

PHOENIX CONTACT

Rotary Measurement Technology Absolute Encoders, Multiturn

B&R X67_IO_System_V3.14_E. X67 - System

Transcription:

Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm x 160mm x 44.5mm (2.362in. x 6.299in. x 1.752in.) 2-, 3-, and 4-wire -25 C to +60 C (-13 F to +131 F) -25 C to +85 C (-13 F to +185 F) 95%. Slight condensation is permitted occasionally on the outer housing, for short periods. Degree of protection IP67 according to IEC 60529 Class of protection Class 3 according to VDE 0106, IEC 60536 Module Power Features Connection to Profibus-DP using M12 connectors Baud rates up to 12 Mbaud autobaud Connection to digital sensors using M12 connectors Flexible voltage supply Diagnostic and status indicators Short-circuit and overload protection of sensor supply IP67 protection Ordering Information Nominal value Range Current consumption U L at Current consumption U S at 18VDC to 30VDC 35mA typical, 100mA maximum 4.5mA typical plus sensor current 700mA maximum IC676ACC001 VersaMax IP Point Labels, qty 50 IC676ACC002 Protective Caps. Male, for unused I/O connectors and/or outgoing bus and power connectors, qty 5 IC676ACC003 Protective Caps, Female, for unused incoming power connections, qty 5 IC676ACC004 Profibus Network Terminating Resistor IC676ACC005 Profibus Network Tee 1

Module Dimensions Internal Circuit Diagram Isolating transformer LED (status indicators) Optocoupler Digital input Isolated area 2

Module LEDs and Rotary Switches LEDs BF UL US XX Red LED Bus failure ON No cyclic data transmission Profibus not connected; master not online Incorrect settings (configuration via master, station address) Synchronization or parameterization running Timeout expired OFF Module is addressed by Profibus and is in the "cyclic process data exchange" state. Missing module supply (in this state the UL LED also is off because of the missing 24V communications voltage. Green LED Communications power ON Communications power present OFF Red/green LED ON (red) ON (green) OFF Yellow LED ON OFF Communications power not present Voltage supply Sensor voltage overload Voltage supply U S greater than 18V Voltage supply is less than 18 volts Input status indicator Input active Input not active Selecting the Station Address The rotary switches are used to set up the two digits that represent the module's station address. Rotary switch X10 selects the first digit, and switch X1 selects the second digit. The Profibus master addresses the module by means of this station address. The address must be a number from 1 to 99. A new address is only accepted when the module is powered up. 3

Module Connectors Connector FE BUS IN BUS OUT U LS IN U LS OUT Function Functional earth ground Profibus In Profibus Out Voltage supply in Voltage supply out for additional modules IN1 TO IN8 Inputs 1 to 8 Connection Guidelines Meet Noise Immunity Requirements. Connect FE using a mounting screw, or (when mounting the module on the side or on a non-conductive surface), using a cable connection to the FE connection point. Ensure IP67 Protection. Cover the unused sockets with protective caps (IC676ACC002 and ACC003). Avoid Damage to the Electronics. Supply the sensors with the apropriate voltage U S at the connection points. Avoid Polarity Reversal of the supply voltages U L and U S. Connect the sensors to the correct points as shown on the next page. Profibus Pin Assignments Pin In Out 1 VP VP 2 RxD/TxD-N (A) RxD/TxD-N (A) 3 DGND DGND 4 RxD/TxD-P (B) RxD/TxD-P (B) The thread is used for shielding. 5 Shield Shield Pin Assignment of the Voltage Supply Pin In Out 1 U L +24V U L +24V 2 U S GND U S GND 3 U L GND U L GND 4 U S +24V U S +24V 4

Pin Assignment of the Inputs 1 US +24V 2 See input socket assignments below 3 GND 4 Input 5 FE Input Socket Assignments Two input signals can be connected to each input socket. If both inputs of the same socket are used. the other socket of the pair (1/2, 3/4, 5/6, 7/8) must not be used. Connection Examples 5

Program Data ID number Input address area Process Input Data Format 066B hex 8 bits The 8-Point Input Module provides 8 bits of process data. Connection points are assigned to these 8 bits as shown below: Module Diagnostic Data Bit Number 7 6 5 4 3 2 1 0 Input 8 7 6 5 4 3 2 1 The module also provides 12 bytes of diagnostic data to the master, in the format shown below. Of this data, bytes 0 through 6 are Profibus standard data. Bytes 7 through 12 are specific to this module. If a diagnostic event occurs, the module generates a telegram containing the diagnostic data to the master. The module can read the current diagnostic data at any time. Byte Number Bit 7 Bit 6 Bit 5 Bit 4 Bit 2 Bit 2 Bit 1 Bit 0 Diagnostic Data Byte 0 X X X X X X X X Station Status 1 Byte 1 X X X X X X X X Station Status 2 Byte 2 X X X X X X X X Station Status 3 Byte 3 X X X X X X X X Master address diagnostics Byte 4 0 0 0 0 0 1 1 0 High ID Number Byte 5 0 1 1 0 1 0 1 1 Low ID Number Byte 6 0 0 0 0 0 1 1 1 Diagnostic header Byte 7 M.7 M.6 M.5 M.4 M.3 M.2 M.1 M.0 Module Diagnostics Byte 8 0 0 0 0 0 0 0 0 Reserved Byte 9 0 0 0 0 0 0 0 0 Reserved Byte 10 0 0 0 0 0 0 0 0 Reserved Byte 11 0 0 0 0 0 0 0 0 Reserved Byte 12 X X 0 0 0 0 0 0 Reserved Byte 7, Format of the Module Diagnostics Data Bit Number Used For Comment M.0 - M.2 Reserved 0 M.3 Status of the US Sensor Supply 1 if the Sensor Supply is less than 18V M.4 - M.5 Reserved 0 M.6 Status of the UL Module Supply 1 if the Module Supply is less than 18V M.7 Overload Status of the US Sensor Supply 1 if the Sensor supply is overloaded 6

Technical Data Discrete Inputs Number 8 Nominal input voltage U IN Permissible range Nominal input current U IN Characteristic curve of the current Delay time Permissible cable length to the sensor -30V < U IN < +30VDC 5mA Linear in the range 1V < U IN < 30 V On: 3.1ms typical Off: 4.1ms typical 100m (328.08ft)) Input Characteristic Curve Input voltage (V) Typical input current (ma) -30 < U IN < 0.7 0 3 0.5 6 1.0 9 1.6 12 2.3 15 3.0 18 3.8 21 4.5 24 5.2 27 6.0 30 6.7 Sensor Supply Minimum sensor voltage Nominal current per channel Nominal current per module Overload Protection Short-circuit protection U S - 1V 75mA 600mA Electronic per module Electronic per module Error Messages Short circuit of sensor supply Overload of sensor supply Yes. If an error is triggered by an overload or short circuit of the sensor supply, the module switches off the sensor supply of the channels and reports a peripheral fault to the master. Yes. If the sensor supply US falls below 18V, the module reports a peripheral fault to he master. Profibus Interface Baud Rate, incoming and outgoing Shield connection, incoming and outgoing 12 Mbaud maximum. For transmission rates above 3 Mbaud, T-pieces with integrated series inductance must be used. Direct to FE 7