Evaluation of Diffusion Techniques for Improved Vessel Visualization and Quantification in Three-Dimensional Rotational Angiography

Size: px
Start display at page:

Download "Evaluation of Diffusion Techniques for Improved Vessel Visualization and Quantification in Three-Dimensional Rotational Angiography"

Transcription

1 Evaluation of Diffusion Techniques for Improved Vessel Visualization and Quantification in Three-Dimensional Rotational Angiography Erik Meijering 1, Wiro Niessen 1, Joachim Weickert 2, and Max Viergever 1 1 Image Sciences Institute, University Medical Center Utrecht, Heidelberglaan 100, NL-3584 CX Utrecht, the Netherlands. {erik,wiro,max}@isi.uu.nl URL: 2 Computer Vision, Graphics and Pattern Recognition Group, Department of Mathematics and Computer Science, University of Mannheim, D Mannheim, Germany. Joachim.Weickert@uni-mannheim.de URL: Abstract. Three-dimensional rotational angiography (3DRA) is a promising imaging technique which yields high-resolution isotropic 3D images of vascular structures. Raw 3DRA images, however, usually suffer from a high noise level and the presence of other artifacts. For accurate visualization and quantification of vascular anomalies, noise reduction is therefore highly desirable. In this paper we analyze the effects of several linear and nonlinear filtering techniques for that purpose. From the results of in vitro experiments we conclude that edge-enhancing anisotropic diffusion is very suitable for mentioned tasks. However, in view of the computational requirements of this technique, the regularized isotropic nonlinear diffusion scheme may be considered a useful alternative. 1 Introduction Three-dimensional rotational angiography (3DRA) is a relatively new technique for imaging blood vessels in the human body [1 5]. Using a standard C-arm imaging system, this technique yields high-resolution isotropic 3D datasets reconstructed from 2D X-ray angiography images acquired during a 180-degree rotation of the X-ray source-detector combination following a single injection of contrast material. The vascular structures of interest can afterwards be studied from any desired angle by the use of 3D visualization techniques. The absence of overprojections and the high resolution of the resulting datasets make the technique also potentially interesting for quantitative studies. However, visualization of raw 3DRA images is usually unacceptable, due to the high noise level and the presence of reconstruction artifacts and unwanted structures resulting from inhomogeneous surrounding tissue. In order to improve In Medical Image Computing and Computer-Assisted Intervention MICCAI 2001, W. J. Niessen and M. A. Viergever (eds.), vol of Lecture Notes in Computer Science, Springer-Verlag, Berlin, 2001, pp

2 PP-2 Meijering et al. the quality of volume and surface renderings, some form of noise reduction must be applied to the raw data prior to visualization. Although application of noise reduction techniques may result in qualitatively better renderings, the effects of such techniques on the subsequent quantification of vessels and vascular anomalies based on those renderings have not yet been reported in the literature. Analysis of these effects is important, as particular techniques may increase the user-dependency of volume and surface renderings which are generally based on one or more user-defined thresholds and thus the reliability of quantitative measurements obtained from those renderings. In this paper we evaluate several linear and nonlinear diffusion filtering techniques for noise reduction by analyzing their effects on the quality of visualization and the accuracy of quantification of vascular anomalies in 3DRA images. 2 Diffusion Techniques The noise reduction techniques considered in this study are uniform filtering, Gaussian filtering or linear diffusion, regularized isotropic nonlinear diffusion, and edge-enhancing anisotropic diffusion, which are briefly described next. Uniform Filtering. The simplest and computationally cheapest approach to reduce noise in images is to average the grey-values of voxels in a cubic neighborhood around each voxel by means of separable uniform filtering (UF): I(x) =(I 0 U m )(x), x =(x, y, z) X, (1) where I 0 denotes the original 3D image, X IR 3 is the image domain, and U m (x) =u m (x)u m (y)u m (z) denotes the 3D normalized uniform filter given by u m (ξ) =m 1 if ξ 1 2 m, m IN odd, and u m(ξ) =0otherwise. Gaussian Filtering. Another frequently used approach to image smoothing is Gaussian filtering (GF), also implemented by separable convolution: I(x) =(I 0 G σ )(x), x =(x, y, z) X, (2) with G σ (x) =g σ (x)g σ (y)g σ (z), and g σ denoting the Gaussian with standard deviation σ. The process (2) constitutes the solution to the linear diffusion equation t I(x; t) = I(x; t), with σ = 2t and initial condition I(x;0)=I 0 (x). Regularized Isotropic Nonlinear Diffusion. The first nonlinear technique included in this study is the regularized version of the Perona-Malik scheme [6]. This scheme (RPM) is obtained from the linear diffusion equation by including a gradient-dependent diffusivity: ( t I(x; t) = D ( I τ (x; t) 2) ) I(x; t), (3) where the gradient is computed at scale σ n = 2τ, τ > 0. In our study, we used [7] D ( ξ 2) =1 exp ( /(ξ/ζ) 8),whereζ > 0 corresponds to the minimum contrast needed for structures in order to be preserved.

3 Evaluation of Diffusion Techniques in 3DRA PP-3 Edge-Enhancing Anisotropic Diffusion. The second nonlinear diffusion technique (EED) does not only take into account the contrast of an edge, but also its orientation. This is achieved by replacing the scalar-valued diffusivity in (3) by a diffusion tensor [7]: ( t I(x; t) = D ( I τ (x; t) ) ) I(x; t), (4) where D is constructed from the system of orthonormal eigenvectors v 1 I(x; τ), v 2 I(x; τ), v 3 I(x; τ) and v 2, and corresponding eigenvalues λ 1 = D ( I(x; τ) 2) and λ 2 = λ 3 = D(0) = 1, with D as in RPM. With this choice of D, smoothing along edges is preferred over smoothing across them. 3 Vascular Anomalies Currently, 3DRA is used primarily for visualization and subsequent quantification of carotid stenosis and intracranial aneurysms [3 5]. We briefly discuss the measures used for quantification of these anomalies. Carotid Stenosis. For the quantification of the degree of stenosis of the internal carotid artery (ICA) we used the North American Symptomatic Carotid Endarterectomy Trial (NASCET) measure and the common carotid measure (CC) [8], respectively defined as D NASCET =(1 d S /d ICA )andd CC =(1 d S /d CCA ), with d S, d ICA,andd CCA as in Fig. 1. Both measures involve measuring the luminal diameter at the point of maximum stenosis (d S ). The NASCET measure furthermore involves the diameter (d ICA ) of a visible portion of disease-free ICA distal to the stenosis, whereas the CC measure uses the diameter (d CCA )ofthe visible disease-free distal common carotid artery (CCA). Fig. 1. Diameters involved in the different measures for quantification of internal carotid stenosis (left) and intracranial saccular aneurysms (right). Intracranial Aneurysms. For quantification of intracranial aneurysms, several measures were considered. The first is the dome diameter (d D, see Fig. 1), which has been shown to relate significantly to risk of rupture [9]. The second measure considered in this study is the diameter of the aneurysmal neck (d N ), which is important in selecting an appropriate clip in the case of surgical intervention or for predicting successful obliteration of the aneurysmal lumen in the case of endovascular treatment [10]. The ratio between diameters d N and d D of the aneurysm has also been suggested as a guideline in deciding between surgical or endovascular treatment [11].

4 PP-4 Meijering et al. 4 Experiments and Results The experiments were carried out on phantoms for which ground truth was available. In this section we describe the phantoms and image acquisition, the method of evaluation, and the results. Phantoms and Image Acquisition. Images were obtained of a carotid anthropomorphic vascular phantom (CAVP) with an asymmetrical stenosis in the ICA, and an intracranial anthropomorphic vascular phantom (IAVP) with a berry aneurysm at the tip of the basilar artery (BA). The phantoms (R. G. Shelley Ltd., North York, Ontario) represent average dimensions of the corresponding vascular structures in the human body: d S = 1.68mm, d ICA = 5.6mm, d CCA =8.0mm, d N =2.6mm, and d D =12.9mm. Each of the phantoms was filled with contrast material (% diluted Ultravist-0, Schering, Weesp) and an Integris V00 C-arm imaging system (Philips Medical Systems, Best) was used to acquire 100 X-ray angiography images (resolution pixels, 10 bits/pixel, see Fig. 2 for examples) during automatic rotation of the C-arm over 180 degrees lasting eight seconds. A modified filtered back-projection algorithm was then applied to generate 3DRA images at resolutions of voxels of size mm 3 and voxels of size mm 3, 16 bits/voxel. Fig. 2. Sample X-ray projection images taken from the rotational angiography runs of the CAVP (left) andtheiavp(right). The images give an impression of the morphology and complexity of the modeled vasculature. Method of Evaluation. We first investigated the capabilities of the filtering techniques to reduce background noise while retaining vessel contrast as much as possible. To this end we measured the contrast-to-noise ratio (CNR) in each of the vessels of interest: CNR = ( I V I B ) 2 /σ 2 B,whereI and σ2 denote image intensity and variance, respectively, and V and B vessel and background regions. For B, a fixed background region was selected in each of the images. The CNR was measured as a function of evolution time, t. This variable is explicitly present in RPM and EED, and together with the temporal step-size t determines the number of iterations of the discretized differential equation to be carried out. For GF we have the relation t = σ 2 /2. For UF we used the same relation, with σ the standard deviation of u m,sothatt = m 2 /24, where m is a discrete variable for which we took values of 1, 3, 5, 7, 9, and 11. To allow a direct comparison of the results of UF and GF, RPM, and EED, the measurements for the latter schemes were carried out at corresponding evolution times t = 0.0 (original), 0.375, 1.042, 2.042, 3.375, and In all experiments,

5 Evaluation of Diffusion Techniques in 3DRA PP-5 the additional parameters of RPM and EED were fixed to σ n =0.5andζ =0.05, which seemed to be appropriate values according to initial experiments. Next, the effects of the techniques on quantification of the vascular anomalies were investigated. Therefore, the diameters d S, d ICA, d CCA, d N,andd D were measured as a function of both t and the threshold parameter θ. Fort we used the same values as in the CNR measurements. The parameter θ is used in practice to separate relevant (vascular) from non-relevant (noise and other) structures in the visualizations, on the base of which quantification takes place. In order to use acquisition independent values for θ, the images were normalized so as to make the average background intensity 0.0 and the average intensity within the vessels 1.0. Together with the ground-truth values, the results allowed for an assessment of both accuracy and robustness to threshold selection of quantitative measurements and their dependency on the filter strength. Finally, we looked at the qualitative (visual) effects of the different noise reduction techniques. These concerned the apparent (not measured) dimensions of the vascular anomalies in 3D visualizations of the filtered 3DRA datasets and their dependency on the user-controlled threshold parameter, as well as the apparent smoothness of the vascular structures in these visualizations. To this end, both exo- and endovascular surface renderings were generated by using a standard Phong shading technique. Results. Because of space limitations we have to confine ourselves here to showing only some of the results and to summarize the overall findings. Examples of CNR measurement results carried out in high-resolution 3DRAs of the CAVP and IAVP are given in Fig. 3. The results showed that the four schemes UF, GF, RPM, and EED reduce noise equally well in vessel segments with a relatively large luminal diameter (typically larger than 10 voxels). For segments with smaller diameters, the nonlinear filtering techniques (RPM and EED) outperformed the linear techniques (UF and GF) for larger evolution times. Whereas the CNR measurements concerned the behavior of the techniques in the background and the interior of vessels, the diameter measurements revealed CNR(t) [db] in stenosis at high res. CNR(t) [db]indomeathighres. 20 UF GF 10 RPM EED UF GF 10 RPM EED Fig. 3. Contrast-to-noise ratio (CNR) as a function of evolution time (t) for the four techniques (UF, GF, RPM, EED), measured in the stenosis (left) and dome (right) in the high-resolution 3DRA reconstruction of the CAVP and IAVP, respectively.

6 PP-6 D NASCET(θ; t) [%]forufathighres t = 0.0 t = 0.4 t = 1.0 t = 2.0 t = 3.4 t = D NASCET(θ; t) [%] for RPM at high res t = 0.0 t = 0.4 t = 1.0 t = 2.0 t = 3.4 t = Meijering et al. D NASCET(θ; t) [%]forgfathighres t = 0.0 t = 0.4 t = 1.0 t = 2.0 t = 3.4 t = D NASCET(θ; t) [%] for EED at high res t = 0.0 t = 0.4 t = 1.0 t = 2.0 t = 3.4 t = Fig. 4. Degree of stenosis (D NASCET) as a function of the user-controlled threshold (θ) and evolution time (t) for the four techniques (UF, GF, RPM, EED), as measured in the high-resolution reconstruction of the CAVP. The true value is D NASCET = 70%. their performance at the transitions from background to vessel. Examples of the results of these experiments are given in Fig. 4. These results showed that, as expected, the linear techniques (UF, GF) dramatically increase the dependency of the measurements on the user-controlled threshold parameter (θ) as the filtering was made stronger (larger t). The RPM scheme, on the other hand, had a negligible influence on this dependency, irrespective of evolution time. The effects of EED on the user-dependency were negligible only in the high-resolution 3DRAs, where all diameters were larger than about five voxels. Finally, examples of exo- and endovascular surface renderings generated from the high-resolution 3DRA images of the CAVP and IAVP after application of the different techniques are shown in Figs. 5 and 6. The renderings show closeups of the vascular anomalies and give a visual impression of the effects of the techniques on the smoothness of the vessel walls and the changes in the apparent dimensions of the anomalies when varying the user-controlled threshold. The renderings support the findings of the quantification experiments: the linear techniques increased the user-dependency of the vascular dimensions, while the negative effects of RPM and EED were marginal. The smoothness of the vessel walls, however, was considerably improved by EED, while most of the noise in these edge regions was retained by RPM.

7 Evaluation of Diffusion Techniques in 3DRA PP-7 UF GF RPM EED θ =0.3 θ =0.5 Fig. 5. Exovascular surface renderings of the IAVP illustrating the effects of the different techniques (UF, GF, RPM, EED) on the smoothness of the vessel walls and the apparent size of especially the neck of the aneurysm when varying the user-controlled threshold parameter (θ). The renderings show a close-up of the neck and the dome of the aneurysm, the BA and both PCAs, at t = UF GF RPM EED θ =0.2 θ =0.4 Fig. 6. Endovascular surface renderings of the CAVP illustrating the effects of the different techniques (UF, GF, RPM, EED) on the smoothness of the vessel walls and the apparent degree of stenosis when varying the user-controlled threshold parameter (θ). The renderings show the ECA (left passage) and the stenosis in the ICA (right passage), viewed from within the CCA, at t =2.042.

8 PP-8 Meijering et al. 5 Discussion and Conclusions Overall, the results of our in vitro experiments suggest that for vessels with sufficiently large luminal diameter, EED is most suitable: the increase in the user-dependency of quantifications and visualizations is considerably less than with UF or GF, and it is better at reducing noise at the vessel walls than RPM. The sub-optimal performance of EED in vessel segments with very small luminal diameters is most probably due to the fact that the amount of blurring in the plane orthogonal to a local gradient is equal in all directions. We suspect that in order for EED to work adequately also in these cases, it is necessary to make a distinction between the directions corresponding to minimal and maximal curvature, which requires the use of second-order information (Hessian). Early experiments with curvature-based anisotropic diffusion schemes [12] have shown promising results, but more elaborate evaluations are required to determine the clinical implications. Other disadvantages of EED are its memory requirements and its relatively high computational cost. If these are decisive factors, RPM may be a reasonable alternative, for which more efficient algorithms exist [7]. References 1. R. Fahrig et al., Use of a C-arm system to generate true three-dimensional computed rotational angiograms: Preliminary in vitro and in vivo results, Am. J. Neuroradiol., vol. 18, 1997, pp B. A. Schueler et al., Three-dimensional vascular reconstruction with a clinical X-ray angiography system, Acad. Radiol., vol. 4, 1997, pp J. Moret et al., 3D rotational angiography: Clinical value in endovascular treatment, Medicamundi, vol. 42, 1998, pp R. Anxionnat et al., 3D angiography: Clinical interest. First applications in interventional neuroradiology, J. Neuroradiol., vol. 25, 1998, pp Y. Trousset et al., A fully automated system for three-dimensional X-ray angiography, in Computer Assisted Radiology and Surgery (CARS 99), Elsevier Science, Amsterdam, 1999, pp F. Catté et al., Image selective smoothing and edge detection by nonlinear diffusion, SIAM J. Num. Anal., vol. 29, 1992, pp J. Weickert, Anisotropic Diffusion in Image Processing, B. G. Teubner, Stuttgart, Germany, P. M. Rothwell et al., Equivalence of measurements of carotid stenosis. a comparison of three methods on 1001 angiograms, Stroke, vol. 25, 1994, pp N. Yasui et al., Subarachnoid hemorrhage caused by previously diagnosed, previously unruptured intracranial aneurysms: A retrospective analysis of 25 cases, Neurosurgery, vol. 39, 1996, pp A. Fernandez Zubillaga et al., Endovascular occlusion of intracranial aneurysms with electrically detachable coils: Correlation of aneurysm neck size and treatment results, Am. J. Neuroradiol., vol. 15, 1994, pp L. Parlea et al., An analysis of the geometry of saccular intracranial aneurysms, Am. J. Neuroradiol., vol. 20, 1999, pp K. Krissian et al., Directional anisotropic diffusion applied to segmentation of vessels in 3D images, in Scale-Space Theory in Computer Vision, vol of Lecture Notes in Computer Science, Springer-Verlag, Berlin, 1997, pp

2D Vessel Segmentation Using Local Adaptive Contrast Enhancement

2D Vessel Segmentation Using Local Adaptive Contrast Enhancement 2D Vessel Segmentation Using Local Adaptive Contrast Enhancement Dominik Schuldhaus 1,2, Martin Spiegel 1,2,3,4, Thomas Redel 3, Maria Polyanskaya 1,3, Tobias Struffert 2, Joachim Hornegger 1,4, Arnd Doerfler

More information

Guide wire tracking in interventional radiology

Guide wire tracking in interventional radiology Guide wire tracking in interventional radiology S.A.M. Baert,W.J. Niessen, E.H.W. Meijering, A.F. Frangi, M.A. Viergever Image Sciences Institute, University Medical Center Utrecht, rm E 01.334, P.O.Box

More information

Comparison of Vessel Segmentations using STAPLE

Comparison of Vessel Segmentations using STAPLE Comparison of Vessel Segmentations using STAPLE Julien Jomier, Vincent LeDigarcher, and Stephen R. Aylward Computer-Aided Diagnosis and Display Lab The University of North Carolina at Chapel Hill, Department

More information

Fast 3D Mean Shift Filter for CT Images

Fast 3D Mean Shift Filter for CT Images Fast 3D Mean Shift Filter for CT Images Gustavo Fernández Domínguez, Horst Bischof, and Reinhard Beichel Institute for Computer Graphics and Vision, Graz University of Technology Inffeldgasse 16/2, A-8010,

More information

Probabilistic Tracking and Model-based Segmentation of 3D Tubular Structures

Probabilistic Tracking and Model-based Segmentation of 3D Tubular Structures Probabilistic Tracking and Model-based Segmentation of 3D Tubular Structures Stefan Wörz, William J. Godinez, Karl Rohr University of Heidelberg, BIOQUANT, IPMB, and DKFZ Heidelberg, Dept. Bioinformatics

More information

Application of level set based method for segmentation of blood vessels in angiography images

Application of level set based method for segmentation of blood vessels in angiography images Lodz University of Technology Faculty of Electrical, Electronic, Computer and Control Engineering Institute of Electronics PhD Thesis Application of level set based method for segmentation of blood vessels

More information

Automatic Cerebral Aneurysm Detection in Multimodal Angiographic Images

Automatic Cerebral Aneurysm Detection in Multimodal Angiographic Images Automatic Cerebral Aneurysm Detection in Multimodal Angiographic Images Clemens M. Hentschke, Oliver Beuing, Rosa Nickl and Klaus D. Tönnies Abstract We propose a system to automatically detect cerebral

More information

Vessel Centerline Tracking in CTA and MRA Images Using Hough Transform

Vessel Centerline Tracking in CTA and MRA Images Using Hough Transform Vessel Centerline Tracking in CTA and MRA Images Using Hough Transform Maysa M.G. Macedo 1, Choukri Mekkaoui 2, and Marcel P. Jackowski 1 1 University of São Paulo, Department of Computer Science, Rua

More information

Edge-Preserving Denoising for Segmentation in CT-Images

Edge-Preserving Denoising for Segmentation in CT-Images Edge-Preserving Denoising for Segmentation in CT-Images Eva Eibenberger, Anja Borsdorf, Andreas Wimmer, Joachim Hornegger Lehrstuhl für Mustererkennung, Friedrich-Alexander-Universität Erlangen-Nürnberg

More information

48 4 Quantitative 3-D MRA: in vitro and in vivo results Endarterectomy Trial (NASCET) [216] and the European Carotid Surgery Trial (ECST) [92], both e

48 4 Quantitative 3-D MRA: in vitro and in vivo results Endarterectomy Trial (NASCET) [216] and the European Carotid Surgery Trial (ECST) [92], both e True genius resides in the capacity for evaluation of uncertain, hazardous, and conflicting information. W. Churchill, 1874-1965 Chapter 4 Quantitative analysis of vascular morphology from 3-D MRA: in

More information

Comparison of Vessel Segmentations Using STAPLE

Comparison of Vessel Segmentations Using STAPLE Comparison of Vessel Segmentations Using STAPLE Julien Jomier, Vincent LeDigarcher, and Stephen R. Aylward Computer-Aided Diagnosis and Display Lab, The University of North Carolina at Chapel Hill, Department

More information

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT Benedikt Lorch 1, Martin Berger 1,2, Joachim Hornegger 1,2, Andreas Maier 1,2 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg

More information

Evaluation of Hessian-based filters to enhance the axis of coronary arteries in CT images

Evaluation of Hessian-based filters to enhance the axis of coronary arteries in CT images International Congress Series 1256 (2003) 1191 1196 Evaluation of Hessian-based filters to enhance the axis of coronary arteries in CT images S.D. Olabarriaga a, *, M. Breeuwer b, W.J. Niessen a a University

More information

MEDICAL IMAGE NOISE REDUCTION AND REGION CONTRAST ENHANCEMENT USING PARTIAL DIFFERENTIAL EQUATIONS

MEDICAL IMAGE NOISE REDUCTION AND REGION CONTRAST ENHANCEMENT USING PARTIAL DIFFERENTIAL EQUATIONS MEDICAL IMAGE NOISE REDUCTION AND REGION CONTRAST ENHANCEMENT USING PARTIAL DIFFERENTIAL EQUATIONS Miguel Alemán-Flores, Luis Álvarez-León Departamento de Informática y Sistemas, Universidad de Las Palmas

More information

Vessel Explorer: a tool for quantitative measurements in CT and MR angiography

Vessel Explorer: a tool for quantitative measurements in CT and MR angiography Clinical applications Vessel Explorer: a tool for quantitative measurements in CT and MR angiography J. Oliván Bescós J. Sonnemans R. Habets J. Peters H. van den Bosch T. Leiner Healthcare Informatics/Patient

More information

Outline 7/2/201011/6/

Outline 7/2/201011/6/ Outline Pattern recognition in computer vision Background on the development of SIFT SIFT algorithm and some of its variations Computational considerations (SURF) Potential improvement Summary 01 2 Pattern

More information

A Fast Technique for Motion Correction in DSA using a Feature-Based, Irregular Grid

A Fast Technique for Motion Correction in DSA using a Feature-Based, Irregular Grid A Fast Technique for Motion Correction in DSA using a Feature-Based, Irregular Grid Erik H. W. Meijering, Karel J. Zuiderveld, Max A. Viergever Image Sciences Institute, Utrecht University, Heidelberglaan

More information

Three-Dimensional Model-Based Stenosis Quantification of the Carotid Arteries from Contrast-Enhanced MR Angiography

Three-Dimensional Model-Based Stenosis Quantification of the Carotid Arteries from Contrast-Enhanced MR Angiography Three-Dimensional Model-Based Stenosis Quantification of the Carotid Arteries from Contrast-Enhanced MR Angiography Alejandro F. Frangi, Wiro J. Niessen, Paul J. Nederkoorn, Otto E.H. Elgersma, Max A.

More information

Automatic Vascular Tree Formation Using the Mahalanobis Distance

Automatic Vascular Tree Formation Using the Mahalanobis Distance Automatic Vascular Tree Formation Using the Mahalanobis Distance Julien Jomier, Vincent LeDigarcher, and Stephen R. Aylward Computer-Aided Diagnosis and Display Lab, Department of Radiology The University

More information

Classification-based summation of cerebral digital subtraction angiography series for image post-processing algorithms

Classification-based summation of cerebral digital subtraction angiography series for image post-processing algorithms IOP PUBLISHING Phys. Med. Biol. 56 (2011) 1791 1802 PHYSICS IN MEDICINE AND BIOLOGY doi:10.1088/0031-9155/56/6/017 Classification-based summation of cerebral digital subtraction angiography series for

More information

Interactive segmentation of vascular structures in CT images for liver surgery planning

Interactive segmentation of vascular structures in CT images for liver surgery planning Interactive segmentation of vascular structures in CT images for liver surgery planning L. Wang¹, C. Hansen¹, S.Zidowitz¹, H. K. Hahn¹ ¹ Fraunhofer MEVIS, Institute for Medical Image Computing, Bremen,

More information

An Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy

An Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy An Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy Chenyang Xu 1, Siemens Corporate Research, Inc., Princeton, NJ, USA Xiaolei Huang,

More information

Three-Dimensional Data Compression with Anisotropic Diffusion

Three-Dimensional Data Compression with Anisotropic Diffusion Three-Dimensional Data Compression with Anisotropic Diffusion Pascal Peter Mathematical Image Analysis Group, Faculty of Mathematics and Computer Science, Campus E1.7, Saarland University, 66041 Saarbrücken,

More information

Experiments with Edge Detection using One-dimensional Surface Fitting

Experiments with Edge Detection using One-dimensional Surface Fitting Experiments with Edge Detection using One-dimensional Surface Fitting Gabor Terei, Jorge Luis Nunes e Silva Brito The Ohio State University, Department of Geodetic Science and Surveying 1958 Neil Avenue,

More information

A 3-D Modeling Scheme for Cerebral Vasculature from MRA Datasets

A 3-D Modeling Scheme for Cerebral Vasculature from MRA Datasets 3-D Modeling Scheme for Cerebral Vasculature from MR Datasets Zhongyuan Qin, Xuanqin Mou Institute of Image Processing Xi'an Jiaotong University Xi'an, Shaanxi 710049, P. R. China Ruofei Zhang Department

More information

Image Analysis, Geometrical Modelling and Image Synthesis for 3D Medical Imaging

Image Analysis, Geometrical Modelling and Image Synthesis for 3D Medical Imaging Image Analysis, Geometrical Modelling and Image Synthesis for 3D Medical Imaging J. SEQUEIRA Laboratoire d'informatique de Marseille - FRE CNRS 2246 Faculté des Sciences de Luminy, 163 avenue de Luminy,

More information

Frequency split metal artifact reduction (FSMAR) in computed tomography

Frequency split metal artifact reduction (FSMAR) in computed tomography The Johns Hopkins University Advanced Computer Integrated Surgery Group 4 Metal Artifact Removal in C-arm Cone-Beam CT Paper Seminar Critical Review of Frequency split metal artifact reduction (FSMAR)

More information

FINDING THE TRUE EDGE IN CTA

FINDING THE TRUE EDGE IN CTA FINDING THE TRUE EDGE IN CTA by: John A. Rumberger, PhD, MD, FACC Your patient has chest pain. The Cardiac CT Angiography shows plaque in the LAD. You adjust the viewing window trying to evaluate the stenosis

More information

Accurate Quantification of Small-Diameter Tubular Structures in Isotropic CT Volume Data Based on Multiscale Line Filter Responses

Accurate Quantification of Small-Diameter Tubular Structures in Isotropic CT Volume Data Based on Multiscale Line Filter Responses Accurate Quantification of Small-Diameter Tubular Structures in Isotropic CT Volume Data Based on Multiscale Line Filter Responses Yoshinobu Sato 1, Shuji Yamamoto 2, and Shinichi Tamura 1 1 Division of

More information

Outlines. Medical Image Processing Using Transforms. 4. Transform in image space

Outlines. Medical Image Processing Using Transforms. 4. Transform in image space Medical Image Processing Using Transforms Hongmei Zhu, Ph.D Department of Mathematics & Statistics York University hmzhu@yorku.ca Outlines Image Quality Gray value transforms Histogram processing Transforms

More information

Modeling and preoperative planning for kidney surgery

Modeling and preoperative planning for kidney surgery Modeling and preoperative planning for kidney surgery Refael Vivanti Computer Aided Surgery and Medical Image Processing Lab Hebrew University of Jerusalem, Israel Advisor: Prof. Leo Joskowicz Clinical

More information

Fuzzy-Based Extraction of Vascular Structures from Time-of-Flight MR Images

Fuzzy-Based Extraction of Vascular Structures from Time-of-Flight MR Images 816 Medical Informatics in a United and Healthy Europe K.-P. Adlassnig et al. (Eds.) IOS Press, 2009 2009 European Federation for Medical Informatics. All rights reserved. doi:10.3233/978-1-60750-044-5-816

More information

Blood Particle Trajectories in Phase-Contrast-MRI as Minimal Paths Computed with Anisotropic Fast Marching

Blood Particle Trajectories in Phase-Contrast-MRI as Minimal Paths Computed with Anisotropic Fast Marching Blood Particle Trajectories in Phase-Contrast-MRI as Minimal Paths Computed with Anisotropic Fast Marching Michael Schwenke 1, Anja Hennemuth 1, Bernd Fischer 2, Ola Friman 1 1 Fraunhofer MEVIS, Institute

More information

MR IMAGE SEGMENTATION

MR IMAGE SEGMENTATION MR IMAGE SEGMENTATION Prepared by : Monil Shah What is Segmentation? Partitioning a region or regions of interest in images such that each region corresponds to one or more anatomic structures Classification

More information

Generalizing vesselness with respect to dimensionality and shape Release 1.00

Generalizing vesselness with respect to dimensionality and shape Release 1.00 Generalizing vesselness with respect to dimensionality and shape Release 1.00 Luca Antiga 1 August 3, 2007 1 Medical Imaging Unit Mario Negri Institute, Bergamo, Italy email: antiga at marionegri.it Abstract

More information

Digital Image Processing

Digital Image Processing Digital Image Processing SPECIAL TOPICS CT IMAGES Hamid R. Rabiee Fall 2015 What is an image? 2 Are images only about visual concepts? We ve already seen that there are other kinds of image. In this lecture

More information

Respiratory Motion Estimation using a 3D Diaphragm Model

Respiratory Motion Estimation using a 3D Diaphragm Model Respiratory Motion Estimation using a 3D Diaphragm Model Marco Bögel 1,2, Christian Riess 1,2, Andreas Maier 1, Joachim Hornegger 1, Rebecca Fahrig 2 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg 2

More information

Nearly automatic vessels segmentation using graph-based energy minimization

Nearly automatic vessels segmentation using graph-based energy minimization Nearly automatic vessels segmentation using graph-based energy minimization Release 1.00 M. Freiman 1, J. Frank 1, L. Weizman 1 E. Nammer 2, O. Shilon 2,, L. Joskowicz 1 and J. Sosna 3 July 16, 2009 1

More information

Improved Non-Local Means Algorithm Based on Dimensionality Reduction

Improved Non-Local Means Algorithm Based on Dimensionality Reduction Improved Non-Local Means Algorithm Based on Dimensionality Reduction Golam M. Maruf and Mahmoud R. El-Sakka (&) Department of Computer Science, University of Western Ontario, London, Ontario, Canada {gmaruf,melsakka}@uwo.ca

More information

Foveal Algorithm for the Detection of Microcalcification Clusters: a FROC Analysis

Foveal Algorithm for the Detection of Microcalcification Clusters: a FROC Analysis Foveal Algorithm for the Detection of Microcalcification Clusters: a FROC Analysis Marius George Linguraru a,b, Michael Brady a and Ruth English c a Medical Vision Laboratory, University of Oxford, Ewert

More information

Package vesselr. R topics documented: April 3, Type Package

Package vesselr. R topics documented: April 3, Type Package Type Package Package vesselr April 3, 2017 Title Gradient and Vesselness Tools for Arrays and NIfTI Images Version 0.2.1 Maintainer Jordan D. Dworkin Simple functions for calculating

More information

Automatic Optimization of Segmentation Algorithms Through Simultaneous Truth and Performance Level Estimation (STAPLE)

Automatic Optimization of Segmentation Algorithms Through Simultaneous Truth and Performance Level Estimation (STAPLE) Automatic Optimization of Segmentation Algorithms Through Simultaneous Truth and Performance Level Estimation (STAPLE) Mahnaz Maddah, Kelly H. Zou, William M. Wells, Ron Kikinis, and Simon K. Warfield

More information

Optical Flow Method for Blood Flow Velocimetry Based on Digital X-Ray Subtraction Angiography: A Brief Review

Optical Flow Method for Blood Flow Velocimetry Based on Digital X-Ray Subtraction Angiography: A Brief Review Optical Flow Method for Blood Flow Velocimetry Based on Digital X-Ray Subtraction Angiography: A Brief Review Zifeng Yang* Department of Mechanical and Materials Engineering, Wright State University, Dayton,

More information

Edge and local feature detection - 2. Importance of edge detection in computer vision

Edge and local feature detection - 2. Importance of edge detection in computer vision Edge and local feature detection Gradient based edge detection Edge detection by function fitting Second derivative edge detectors Edge linking and the construction of the chain graph Edge and local feature

More information

Obtaining Feature Correspondences

Obtaining Feature Correspondences Obtaining Feature Correspondences Neill Campbell May 9, 2008 A state-of-the-art system for finding objects in images has recently been developed by David Lowe. The algorithm is termed the Scale-Invariant

More information

Analysis of Functional MRI Timeseries Data Using Signal Processing Techniques

Analysis of Functional MRI Timeseries Data Using Signal Processing Techniques Analysis of Functional MRI Timeseries Data Using Signal Processing Techniques Sea Chen Department of Biomedical Engineering Advisors: Dr. Charles A. Bouman and Dr. Mark J. Lowe S. Chen Final Exam October

More information

Quantitative IntraVascular UltraSound (QCU)

Quantitative IntraVascular UltraSound (QCU) Quantitative IntraVascular UltraSound (QCU) Authors: Jouke Dijkstra, Ph.D. and Johan H.C. Reiber, Ph.D., Leiden University Medical Center, Dept of Radiology, Leiden, The Netherlands Introduction: For decades,

More information

DETECTING and extracting blood vessels in magnetic resonance

DETECTING and extracting blood vessels in magnetic resonance 1224 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 26, NO. 9, SEPTEMBER 2007 Weighted Local Variance-Based Edge Detection and Its Application to Vascular Segmentation in Magnetic Resonance Angiography Max

More information

Artistic Stylization of Images and Video Part III Anisotropy and Filtering Eurographics 2011

Artistic Stylization of Images and Video Part III Anisotropy and Filtering Eurographics 2011 Artistic Stylization of Images and Video Part III Anisotropy and Filtering Eurographics 2011 Hasso-Plattner-Institut, University of Potsdam, Germany Image/Video Abstraction Stylized Augmented Reality for

More information

Phantom-based evaluation of a semi-automatic segmentation algorithm for cerebral vascular structures in 3D ultrasound angiography (3D USA)

Phantom-based evaluation of a semi-automatic segmentation algorithm for cerebral vascular structures in 3D ultrasound angiography (3D USA) Phantom-based evaluation of a semi-automatic segmentation algorithm for cerebral vascular structures in 3D ultrasound angiography (3D USA) C. Chalopin¹, K. Krissian², A. Müns 3, F. Arlt 3, J. Meixensberger³,

More information

GENERAL AUTOMATED FLAW DETECTION SCHEME FOR NDE X-RAY IMAGES

GENERAL AUTOMATED FLAW DETECTION SCHEME FOR NDE X-RAY IMAGES GENERAL AUTOMATED FLAW DETECTION SCHEME FOR NDE X-RAY IMAGES Karl W. Ulmer and John P. Basart Center for Nondestructive Evaluation Department of Electrical and Computer Engineering Iowa State University

More information

A Comprehensive Method for Geometrically Correct 3-D Reconstruction of Coronary Arteries by Fusion of Intravascular Ultrasound and Biplane Angiography

A Comprehensive Method for Geometrically Correct 3-D Reconstruction of Coronary Arteries by Fusion of Intravascular Ultrasound and Biplane Angiography Computer-Aided Diagnosis in Medical Imaging, September 20-23, 1998, Chicago IL Elsevier ICS 1182 A Comprehensive Method for Geometrically Correct 3-D Reconstruction of Coronary Arteries by Fusion of Intravascular

More information

3D Guide Wire Navigation from Single Plane Fluoroscopic Images in Abdominal Catheterizations

3D Guide Wire Navigation from Single Plane Fluoroscopic Images in Abdominal Catheterizations 3D Guide Wire Navigation from Single Plane Fluoroscopic Images in Abdominal Catheterizations Martin Groher 2, Frederik Bender 1, Ali Khamene 3, Wolfgang Wein 3, Tim Hauke Heibel 2, Nassir Navab 2 1 Siemens

More information

A Quadrature Filter Approach for Registration Accuracy Assessment of Fundus Images

A Quadrature Filter Approach for Registration Accuracy Assessment of Fundus Images A Quadrature Filter Approach for Registration Accuracy Assessment of Fundus Images Kedir M. Adal 1,3, Rosalie Couvert, D.W.J. Meijer, Jose P. Martinez 2, Koenraad A. Vermeer 1, L.J. van Vliet 3 1 Rotterdam

More information

Automatic No-Reference Quality Assessment for Retinal Fundus Images Using Vessel Segmentation

Automatic No-Reference Quality Assessment for Retinal Fundus Images Using Vessel Segmentation Automatic No-Reference Quality Assessment for Retinal Fundus Images Using Vessel Segmentation Thomas Köhler 1,2, Attila Budai 1,2, Martin F. Kraus 1,2, Jan Odstrčilik 4,5, Georg Michelson 2,3, Joachim

More information

Super-resolution Reconstruction of Fetal Brain MRI

Super-resolution Reconstruction of Fetal Brain MRI Super-resolution Reconstruction of Fetal Brain MRI Ali Gholipour and Simon K. Warfield Computational Radiology Laboratory Children s Hospital Boston, Harvard Medical School Worshop on Image Analysis for

More information

Respiratory Motion Compensation for C-arm CT Liver Imaging

Respiratory Motion Compensation for C-arm CT Liver Imaging Respiratory Motion Compensation for C-arm CT Liver Imaging Aline Sindel 1, Marco Bögel 1,2, Andreas Maier 1,2, Rebecca Fahrig 3, Joachim Hornegger 1,2, Arnd Dörfler 4 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg

More information

Filters. Advanced and Special Topics: Filters. Filters

Filters. Advanced and Special Topics: Filters. Filters Filters Advanced and Special Topics: Filters Dr. Edmund Lam Department of Electrical and Electronic Engineering The University of Hong Kong ELEC4245: Digital Image Processing (Second Semester, 2016 17)

More information

Depth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences

Depth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences Depth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences Jian Wang 1,2, Anja Borsdorf 2, Joachim Hornegger 1,3 1 Pattern Recognition Lab, Friedrich-Alexander-Universität

More information

Generation of Triangle Meshes from Time-of-Flight Data for Surface Registration

Generation of Triangle Meshes from Time-of-Flight Data for Surface Registration Generation of Triangle Meshes from Time-of-Flight Data for Surface Registration Thomas Kilgus, Thiago R. dos Santos, Alexander Seitel, Kwong Yung, Alfred M. Franz, Anja Groch, Ivo Wolf, Hans-Peter Meinzer,

More information

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION Frank Dong, PhD, DABR Diagnostic Physicist, Imaging Institute Cleveland Clinic Foundation and Associate Professor of Radiology

More information

Cerebral Artery Segmentation with Level Set Methods

Cerebral Artery Segmentation with Level Set Methods H. Ho, P. Bier, G. Sands, P. Hunter, Cerebral Artery Segmentation with Level Set Methods, Proceedings of Image and Vision Computing New Zealand 2007, pp. 300 304, Hamilton, New Zealand, December 2007.

More information

18 3 Model-based quantitation of 3-D MRA images investigation [91, 92]. These findings support the relevance of accurate measurement techniques of vas

18 3 Model-based quantitation of 3-D MRA images investigation [91, 92]. These findings support the relevance of accurate measurement techniques of vas People seldom improve when they have no other model but themselves to copy after. O. Goldsmith, 1730-1774 Chapter 3 Model-based quantitation of 3-D Magnetic Resonance angiographic images Abstract Quantification

More information

Color Space Invariance for Various Edge Types in Simple Images. Geoffrey Hollinger and Dr. Bruce Maxwell Swarthmore College Summer 2003

Color Space Invariance for Various Edge Types in Simple Images. Geoffrey Hollinger and Dr. Bruce Maxwell Swarthmore College Summer 2003 Color Space Invariance for Various Edge Types in Simple Images Geoffrey Hollinger and Dr. Bruce Maxwell Swarthmore College Summer 2003 Abstract This paper describes a study done to determine the color

More information

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging 1 CS 9 Final Project Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging Feiyu Chen Department of Electrical Engineering ABSTRACT Subject motion is a significant

More information

Carotid Lumen Segmentation and Stenosis Grading Challenge

Carotid Lumen Segmentation and Stenosis Grading Challenge Carotid Lumen Segmentation and Stenosis Grading Challenge Reinhard Hameeteman Maria Zuluaga Leo Joskowicz Moti Freiman Theo van Walsum version 1.00 may 07, 2009 This document contains a description of

More information

Total Variation Regularization Method for 3D Rotational Coronary Angiography

Total Variation Regularization Method for 3D Rotational Coronary Angiography Total Variation Regularization Method for 3D Rotational Coronary Angiography Haibo Wu 1,2, Christopher Rohkohl 1,3, Joachim Hornegger 1,2 1 Pattern Recognition Lab (LME), Department of Computer Science,

More information

Multiscale Blood Vessel Segmentation in Retinal Fundus Images

Multiscale Blood Vessel Segmentation in Retinal Fundus Images Multiscale Blood Vessel Segmentation in Retinal Fundus Images Attila Budai 1, Georg Michelson 2, Joachim Hornegger 1 1 Pattern Recognition Lab and Graduate School in Advanced Optical Technologies(SAOT),

More information

Filtering and Edge Detection. Computer Vision I. CSE252A Lecture 10. Announcement

Filtering and Edge Detection. Computer Vision I. CSE252A Lecture 10. Announcement Filtering and Edge Detection CSE252A Lecture 10 Announcement HW1graded, will be released later today HW2 assigned, due Wed. Nov. 7 1 Image formation: Color Channel k " $ $ # $ I r I g I b % " ' $ ' = (

More information

MEDICAL IMAGE COMPUTING (CAP 5937) LECTURE 4: Pre-Processing Medical Images (II)

MEDICAL IMAGE COMPUTING (CAP 5937) LECTURE 4: Pre-Processing Medical Images (II) SPRING 2016 1 MEDICAL IMAGE COMPUTING (CAP 5937) LECTURE 4: Pre-Processing Medical Images (II) Dr. Ulas Bagci HEC 221, Center for Research in Computer Vision (CRCV), University of Central Florida (UCF),

More information

Computer Vision I - Filtering and Feature detection

Computer Vision I - Filtering and Feature detection Computer Vision I - Filtering and Feature detection Carsten Rother 30/10/2015 Computer Vision I: Basics of Image Processing Roadmap: Basics of Digital Image Processing Computer Vision I: Basics of Image

More information

IMAGE PROCESSING FOR MEASUREMENT OF INTIMA MEDIA THICKNESS

IMAGE PROCESSING FOR MEASUREMENT OF INTIMA MEDIA THICKNESS 3rd SPLab Workshop 2013 1 www.splab.cz IMAGE PROCESSING FOR MEASUREMENT OF INTIMA MEDIA THICKNESS Ing. Radek Beneš Department of Telecommunications FEEC, Brno University of Technology OUTLINE 2 Introduction

More information

An ICA based Approach for Complex Color Scene Text Binarization

An ICA based Approach for Complex Color Scene Text Binarization An ICA based Approach for Complex Color Scene Text Binarization Siddharth Kherada IIIT-Hyderabad, India siddharth.kherada@research.iiit.ac.in Anoop M. Namboodiri IIIT-Hyderabad, India anoop@iiit.ac.in

More information

3D Vascular Segmentation using MRA Statistics and Velocity Field Information in PC-MRA

3D Vascular Segmentation using MRA Statistics and Velocity Field Information in PC-MRA 3D Vascular Segmentation using MRA Statistics and Velocity Field Information in PC-MRA Albert C. S. Chung 1, J. Alison Noble 1, Paul Summers 2 and Michael Brady 1 1 Department of Engineering Science, Oxford

More information

SUMMARY: DISTINCTIVE IMAGE FEATURES FROM SCALE- INVARIANT KEYPOINTS

SUMMARY: DISTINCTIVE IMAGE FEATURES FROM SCALE- INVARIANT KEYPOINTS SUMMARY: DISTINCTIVE IMAGE FEATURES FROM SCALE- INVARIANT KEYPOINTS Cognitive Robotics Original: David G. Lowe, 004 Summary: Coen van Leeuwen, s1460919 Abstract: This article presents a method to extract

More information

gruvi Edge Aware Anisotropic Diffusion for 3D Scalar Data graphics + usability + visualization Simon Fraser University Burnaby, BC Canada.

gruvi Edge Aware Anisotropic Diffusion for 3D Scalar Data graphics + usability + visualization Simon Fraser University Burnaby, BC Canada. gruvi graphics + usability + visualization Edge Aware Anisotropic Diffusion for 3D Scalar Data Zahid Hossain Torsten Möller Simon Fraser University Burnaby, BC Canada. Motivation Original Sheep s heart

More information

NIH Public Access Author Manuscript Proc Soc Photo Opt Instrum Eng. Author manuscript; available in PMC 2014 October 07.

NIH Public Access Author Manuscript Proc Soc Photo Opt Instrum Eng. Author manuscript; available in PMC 2014 October 07. NIH Public Access Author Manuscript Published in final edited form as: Proc Soc Photo Opt Instrum Eng. 2014 March 21; 9034: 903442. doi:10.1117/12.2042915. MRI Brain Tumor Segmentation and Necrosis Detection

More information

Total Variation Regularization Method for 3-D Rotational Coronary Angiography

Total Variation Regularization Method for 3-D Rotational Coronary Angiography Total Variation Regularization Method for 3-D Rotational Coronary Angiography Haibo Wu 1,2, Christopher Rohkohl 1,3, Joachim Hornegger 1,2 1 Pattern Recognition Lab (LME), Department of Computer Science,

More information

Rigid and Deformable Vasculature-to-Image Registration : a Hierarchical Approach

Rigid and Deformable Vasculature-to-Image Registration : a Hierarchical Approach Rigid and Deformable Vasculature-to-Image Registration : a Hierarchical Approach Julien Jomier and Stephen R. Aylward Computer-Aided Diagnosis and Display Lab The University of North Carolina at Chapel

More information

Linköping University Post Print. Phase Based Level Set Segmentation of Blood Vessels

Linköping University Post Print. Phase Based Level Set Segmentation of Blood Vessels Post Print Phase Based Level Set Segmentation of Blood Vessels Gunnar Läthén, Jimmy Jonasson and Magnus Borga N.B.: When citing this work, cite the original article. 2009 IEEE. Personal use of this material

More information

A Hybrid Method for Coronary Artery Stenoses Detection and Quantification in CTA Images

A Hybrid Method for Coronary Artery Stenoses Detection and Quantification in CTA Images A Hybrid Method for Coronary Artery Stenoses Detection and Quantification in CTA Images İlkay Öksüz 1, Devrim Ünay 2, Kamuran Kadıpaşaoğlu 2 1 Electrical and Electronics Engineering, Bahçeşehir University,

More information

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation Bastian Bier 1, Chris Schwemmer 1,2, Andreas Maier 1,3, Hannes G. Hofmann 1, Yan Xia 1, Joachim Hornegger 1,2, Tobias Struffert

More information

High Performance GPU-Based Preprocessing for Time-of-Flight Imaging in Medical Applications

High Performance GPU-Based Preprocessing for Time-of-Flight Imaging in Medical Applications High Performance GPU-Based Preprocessing for Time-of-Flight Imaging in Medical Applications Jakob Wasza 1, Sebastian Bauer 1, Joachim Hornegger 1,2 1 Pattern Recognition Lab, Friedrich-Alexander University

More information

Constrained Reconstruction of Sparse Cardiac MR DTI Data

Constrained Reconstruction of Sparse Cardiac MR DTI Data Constrained Reconstruction of Sparse Cardiac MR DTI Data Ganesh Adluru 1,3, Edward Hsu, and Edward V.R. DiBella,3 1 Electrical and Computer Engineering department, 50 S. Central Campus Dr., MEB, University

More information

Projection-Based Needle Segmentation in 3D Ultrasound Images

Projection-Based Needle Segmentation in 3D Ultrasound Images Projection-Based Needle Segmentation in 3D Ultrasound Images Mingyue Ding and Aaron Fenster Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, ON, Canada, N6A 5K8 ^PGLQJDIHQVWHU`#LPDJLQJUREDUWVFD

More information

Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay

Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay Jian Wang, Anja Borsdorf, Benno Heigl, Thomas Köhler, Joachim Hornegger Pattern Recognition Lab, Friedrich-Alexander-University

More information

Image Acquisition Systems

Image Acquisition Systems Image Acquisition Systems Goals and Terminology Conventional Radiography Axial Tomography Computer Axial Tomography (CAT) Magnetic Resonance Imaging (MRI) PET, SPECT Ultrasound Microscopy Imaging ITCS

More information

SIFT: SCALE INVARIANT FEATURE TRANSFORM SURF: SPEEDED UP ROBUST FEATURES BASHAR ALSADIK EOS DEPT. TOPMAP M13 3D GEOINFORMATION FROM IMAGES 2014

SIFT: SCALE INVARIANT FEATURE TRANSFORM SURF: SPEEDED UP ROBUST FEATURES BASHAR ALSADIK EOS DEPT. TOPMAP M13 3D GEOINFORMATION FROM IMAGES 2014 SIFT: SCALE INVARIANT FEATURE TRANSFORM SURF: SPEEDED UP ROBUST FEATURES BASHAR ALSADIK EOS DEPT. TOPMAP M13 3D GEOINFORMATION FROM IMAGES 2014 SIFT SIFT: Scale Invariant Feature Transform; transform image

More information

CHAPTER 2. Morphometry on rodent brains. A.E.H. Scheenstra J. Dijkstra L. van der Weerd

CHAPTER 2. Morphometry on rodent brains. A.E.H. Scheenstra J. Dijkstra L. van der Weerd CHAPTER 2 Morphometry on rodent brains A.E.H. Scheenstra J. Dijkstra L. van der Weerd This chapter was adapted from: Volumetry and other quantitative measurements to assess the rodent brain, In vivo NMR

More information

Panoramic Image Stitching

Panoramic Image Stitching Mcgill University Panoramic Image Stitching by Kai Wang Pengbo Li A report submitted in fulfillment for the COMP 558 Final project in the Faculty of Computer Science April 2013 Mcgill University Abstract

More information

An Advanced Automatic Fuzzy Rule-Based Algorithm for 3D Vessel Segmentation

An Advanced Automatic Fuzzy Rule-Based Algorithm for 3D Vessel Segmentation An Advanced Automatic Fuzzy Rule-Based Algorithm for 3D Vessel Segmentation Mohamed A. Abdou *1, Ashraf El-Sayed 2, Eman Ali 2 1 Informatics Research Institute, City for Scientific, Research & Technology

More information

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION Philips J. Res. 51 (1998) 197-201 FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION This special issue of Philips Journalof Research includes a number of papers presented at a Philips

More information

Optimization of Flow Diverter Treatment for a Patient-specific Giant Aneurysm Using STAR-CCM+ László Daróczy, Philipp Berg, Gábor Janiga

Optimization of Flow Diverter Treatment for a Patient-specific Giant Aneurysm Using STAR-CCM+ László Daróczy, Philipp Berg, Gábor Janiga Optimization of Flow Diverter Treatment for a Patient-specific Giant Aneurysm Using STAR-CCM+ László Daróczy, Philipp Berg, Gábor Janiga Introduction Definition of aneurysm: permanent and locally limited

More information

Computer Vision for HCI. Topics of This Lecture

Computer Vision for HCI. Topics of This Lecture Computer Vision for HCI Interest Points Topics of This Lecture Local Invariant Features Motivation Requirements, Invariances Keypoint Localization Features from Accelerated Segment Test (FAST) Harris Shi-Tomasi

More information

Landmark-based 3D Elastic Registration of Pre- and Postoperative Liver CT Data

Landmark-based 3D Elastic Registration of Pre- and Postoperative Liver CT Data Landmark-based 3D Elastic Registration of Pre- and Postoperative Liver CT Data An Experimental Comparison Thomas Lange 1, Stefan Wörz 2, Karl Rohr 2, Peter M. Schlag 3 1 Experimental and Clinical Research

More information

Lecture 7: Most Common Edge Detectors

Lecture 7: Most Common Edge Detectors #1 Lecture 7: Most Common Edge Detectors Saad Bedros sbedros@umn.edu Edge Detection Goal: Identify sudden changes (discontinuities) in an image Intuitively, most semantic and shape information from the

More information

Segmentation and Grouping

Segmentation and Grouping Segmentation and Grouping How and what do we see? Fundamental Problems ' Focus of attention, or grouping ' What subsets of pixels do we consider as possible objects? ' All connected subsets? ' Representation

More information

Denoising an Image by Denoising its Components in a Moving Frame

Denoising an Image by Denoising its Components in a Moving Frame Denoising an Image by Denoising its Components in a Moving Frame Gabriela Ghimpețeanu 1, Thomas Batard 1, Marcelo Bertalmío 1, and Stacey Levine 2 1 Universitat Pompeu Fabra, Spain 2 Duquesne University,

More information

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Computational Medical Imaging Analysis Chapter 4: Image Visualization Computational Medical Imaging Analysis Chapter 4: Image Visualization Jun Zhang Laboratory for Computational Medical Imaging & Data Analysis Department of Computer Science University of Kentucky Lexington,

More information

Nonlinear Diffusion Scale-Space and Fast Marching Level Sets for Segmentation of MR Imagery and Volume Estimation of Stroke Lesions

Nonlinear Diffusion Scale-Space and Fast Marching Level Sets for Segmentation of MR Imagery and Volume Estimation of Stroke Lesions Nonlinear Diffusion Scale-Space and Fast Marching Level Sets for Segmentation of MR Imagery and Volume Estimation of Stroke Lesions Jerod Weinman 1, George Bissias 1, Joseph Horowitz 2, Edward Riseman

More information