1 Influence of Relevant Fluid Parameters on Pressure Pulsation of a Variable Lubricant Vane Pump Thomas Fischer, development/calculation Jan Fischer, development/testing Nico Jäkel, development/construction Mercedes-Benz Berlin Plant Frankfurt/Main, October

2 Outline 1. Introduction 2. Configuration of the Simulation Model in GT Suite 3. Calibration of the Simulation Model Based on Measurements on the Reduced Main Unit Test Bench 4. Calculation of the Influence of Relevant Fluid Parameters 5. Summary

3 1. Introduction

4 1. Introduction Structure and Function of the Vane-type Pump Pressure port Chain drive Vane type pump Pressure-relief valve Pressure control valve Suction port Electromagnetic valve Lubricant vane type pump of the new inline-4 gasoline engine for Mercedes-Benz passenger cars

5 1. Introduction Structure and Function of the Vane-type Pump Outlet Port Chamber Chamber Inlet Port The fluid is sucked in and displaced by the change in volume of the chambers. The volumetric flow of the pump is proportional to the volume change of the chambers over the rotation angle of the pump rotor.

6 1. Introduction Structure and Function of the Vane-type Pump Outlet Port Chamber Chamber Inlet Port The fluid is sucked in and displaced by the change in volume of the chambers. The volumetric flow of the pump is proportional to the change in volume of the chambers over the rotation angle of the pump rotor. The change in volume of the chambers, and with that, the volumetric flow of the pump, is varied by the displacement of the set collar.

7 1. Introduction Task Description for the Simulation Measurement of the dynamic oil pressure curve on a real engine speed pressure cooler inlet pressure cooler outlet Time [s] Speed over time Pressure on the oil cooler inlet and outlet vs. time

8 1. Introduction Task Description for the Simulation Which factors significantly influence the amplitudes 7000 of the pressure pulsation? 6000 Can the calculated pressure curve be calibrated in 5000 line with the measurements by varying the relevant 4000 influencing factors? 3000 Can the effect of the non-influenceable fluid parameters on the pressure curve be reduced? speed pressure cooler inlet pressure cooler outlet Increasing the robustness of the system Time [s] Measurement of the dynamic oil pressure curve on a real engine Speed over time Pressure on the oil cooler inlet and outlet vs. time

9 1. Introduction Task Description for the Simulation Avoidance of component damage through: 1. Optimization of the components relevant to pressure pulsation during the digital assembly stage, 2. Calculation of reliable load collectives for the technical specifications of components and assemblies, Damage to an oil-water heat exchangers in the test engine 3. Computational validation of component changes.

10 2. Configuration of the Simulation Model in GT Suite

11 2. Configuration of the Simulation Model in GT Suite GT Map The geometry of the conveying chamber and the inlets and outlets are measured in CAD. Engine oil circuit highly simplified

12 2. Configuration of the Simulation Model in GT Suite GT Map The geometry of the conveying chamber and the inlets and outlets are measured in CAD. Engine oil circuit highly simplified

13 2. Configuration of the Simulation Model in GT Suite Modeling of the Fluid Oil-air mixture with a variable proportion of free air in the oil Fluid-Liquid-Aeration Aeration Model Object Initial Gas Fraction Bunsen Coefficient Gas Properties Object Liquid Properties Object Time Constant for free => dissolved Time Constant for dissolved => free Oil Properties Properties of air

14 3. Calibration of the Simulation Model Based on Measurements from the Reduced Main Unit Test Bench

15 3. Calibration of the Simulation Model to Correspond to Measurement Data GT map for the calibration of the vane type pump Simplification of the test rig in the assembly laboratory Adaptation of the simulation model to the simplified test rig

16 3. Calibration of the Simulation Model to Correspond to Measurement Data Comparison of the results with measurements on the reduced Main Unit Test Stand Pressure according to pump over time n=2,800 rpm 2800rpm Measure Time Constant for Free=>Dissolved Air T f=>d =0.05 s 2800rpm GTI-Simulation InitialGasFraction=0 2800rpm GTI-Simulation InitialGasFraction=0,1% time [s] The air in the pressure range is fully dissolved.

17 3. Calibration of the Simulation Model in Line With Measurement Data Comparison of the results with measurements on the reduced Main Unit Test Stand Pressure Good consistency of the calculated pressure curve with the measured pressure curve according to pump over time n=2,800 rpm Time Constant for Free=>Dissolved Air T f=>d =5 s 2800rpm Measure 2800rpm GTI-Simulation InitialGasFraction=0,1% TC(Fr The air is entirely free time [s]

18 4. Calculation of the Influence of Relevant Fluid Parameters

19 4. Calculation of the Influence of Relevant Fluid Parameters Factors Involved in the Calculation Factor Level Initial Gas Fraction 0 0,1 % 5% 10% 20 % Bunsen Coefficient 0,07 0,09 Time Constant for free => dissolved Time Constant for dissolved => free 0,01 0, E-5 1E-2 Oil Properties Oil "A" Oil "B" 2x DOE run with 80 Cases per run

20 4. Calculation of the Influence of Relevant Fluid Parameters Graphic showing the effects of the factors on the amplitude sum of the pressure pulsation Initial gas content and the dissolved time constant have a clear effect The freed time constant has a minimal effect The Bunsen coefficient and oil type have negligible effects

21 4. Calculation of the Influence of Relevant Fluid Parameters Comparison of the results with measurements on the running engine Pressure on the inlet of the oilwater heat exchanger over time n=6,300 rpm T=115 deg speed pressure cooler inlet pressure cooler outlet Time [s]

22 4. Calculation of the Influence of Relevant Fluid Parameters Comparison of the results with measurements on the running engine Pressure on the inlet of the oilwater heat exchanger over time n=6,300 rpm T=115 deg speed pressure cooler inlet pressure cooler outlet Time [s]

23 4. Calculation of the Influence of Relevant Fluid Parameters Comparison of the results with measurements on the running engine Pressure on the inlet of the oilwater heat exchanger over time n=6,300 rpm T=115 deg speed Measure real engine Oil Temp pressure 115deg cooler, n=6300rpm inlet GTI-Simulation n=6300rpm pressure DOE-Set cooler 18 outlet Time time [s]

24 4. Calculation of the Influence of Relevant Fluid Parameters Comparison of the results with measurements on the running engine Pressure on the inlet of the oilwater heat exchanger over time n=6,300 rpm T=115 deg Measure real engine Oil Temp 115deg, n=6300rpm GTI-Simulation n=6300rpm DOE-Set time [s]

25 5. Summary Summary The fluid parameters "Initial Gas Fraction" and "Time Constant for free => dissolved" are the main influencing factors on the result of the simulation. Through the variation of the relevant fluid parameters, the simulation result can be very effectively calibrated in line with testing. Reliable load collectives can be calculated with the existing simulation model. The effect of geometric modification can be calculated up to a certain point. The effect of localized pseudo-cavitation effects on complex geometries cannot be calculated.

26 Thank you for your attention! Special thanks to the GT support team.

Co-Simulation von Flownex und ANSYS CFX am Beispiel einer Verdrängermaschine

Co-Simulation von Flownex und ANSYS CFX am Beispiel einer Verdrängermaschine Co-Simulation von Flownex und ANSYS CFX am Beispiel einer Verdrängermaschine Benoit Bosc-Bierne, Dr. Andreas Spille-Kohoff, Farai Hetze CFX Berlin Software GmbH, Berlin Contents Positive displacement compressors

More information

STAR Global Conference 2012 Noordwijk, March 20-21, The InDesA Virtual Test Bench. Dr. Fabiano Bet Dr. Gerald Seider

STAR Global Conference 2012 Noordwijk, March 20-21, The InDesA Virtual Test Bench. Dr. Fabiano Bet Dr. Gerald Seider STAR Global Conference 2012 Noordwijk, March 20-21, 2012 The InDesA Dr. Fabiano Bet Dr. Gerald Seider Company Profile Consulting- & Engineering Services Simulation and Analysis of complex fluid flow and

More information

CFD Simulation of Cavitation in an Internal Gear Pump

CFD Simulation of Cavitation in an Internal Gear Pump CFD Simulation of Cavitation in an Internal Gear Pump Dr. Andreas Spille-Kohoff Jan Hesse CFX Berlin Software GmbH Berlin andreas.spille@cfx-berlin.de Contents Introduction Geometry and mesh Simulation

More information

CFD Simulation of a dry Scroll Vacuum Pump including Leakage Flows

CFD Simulation of a dry Scroll Vacuum Pump including Leakage Flows CFD Simulation of a dry Scroll Vacuum Pump including Leakage Flows Jan Hesse, Rainer Andres CFX Berlin Software GmbH, Berlin, Germany 1 Introduction Numerical simulation results of a dry scroll vacuum

More information

Webinar: TwinMesh for Reliable CFD Analysis of Rotating Positive Displacement Machines

Webinar: TwinMesh for Reliable CFD Analysis of Rotating Positive Displacement Machines Webinar: TwinMesh for Reliable CFD Analysis of Rotating Positive Displacement Machines 14.07.2015 Dipl.-Ing. Jan Hesse Jan.hesse@cfx-berlin.de CFX Berlin Software GmbH Karl-Marx-Allee 90 A 10243 Berlin

More information

MOLLIER DIAGRAM CAN BE IMPROVED!

MOLLIER DIAGRAM CAN BE IMPROVED! MOLLIER DIAGRAM CAN BE IMPROVED! IMPROVED BASIC COOLING CIRCUIT PERFORMANCE EFFICIENCY USING AN ECONOMISER Eng. Jonny Malachi, VP Operations, Mashav Refrigeration and Air Conditioning Engineering Ltd.

More information

Figure 2: Water Into Kerosene, Volume Fraction (Left) And Total Density Of Mixture (Right)

Figure 2: Water Into Kerosene, Volume Fraction (Left) And Total Density Of Mixture (Right) Jared Bottlinger MAE598 Project 3 11/16/17 Task 1 a) Figure 1: Volume Fraction Of Water At 0.4s Task 1 b) Figure 2: Water Into Kerosene, Volume Fraction (Left) And Total Density Of Mixture (Right) Task

More information

Ten Years of Field Experience with Flashing Two-Phase LNG Expanders GASEX 2012

Ten Years of Field Experience with Flashing Two-Phase LNG Expanders GASEX 2012 Ten Years of Field Experience with Flashing Two-Phase LNG Expanders Hans E. Kimmel Research & Development Ebara International Corporation Sparks, Nevada, USA hkimmel@ebaraintl.com GASEX 2012 Conference

More information

LINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ

LINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ Hitachi screw chiller unit widely used for air conditioning and industrial purposes Newly released, equipped with a new screw compressor realizing drastic energy saving and great functionality ( RCUP75AUZ

More information

Two-phase chamber modelling of a twin-screw expander for Trilateral Flash Cycle applications

Two-phase chamber modelling of a twin-screw expander for Trilateral Flash Cycle applications Two-phase chamber modelling of a twin-screw expander for Trilateral Flash Cycle applications Giuseppe Bianchi 1, Stuart Kennedy 3, Obadah Zaher 2, Savvas A. Tassou 1, Jeremy Miller 2, Hussam Jouhara 1

More information

Advances in Turbomachinery Simulation Fred Mendonça and material prepared by Chad Custer, Turbomachinery Technology Specialist

Advances in Turbomachinery Simulation Fred Mendonça and material prepared by Chad Custer, Turbomachinery Technology Specialist Advances in Turbomachinery Simulation Fred Mendonça and material prepared by Chad Custer, Turbomachinery Technology Specialist Usage From Across the Industry Outline Key Application Objectives Conjugate

More information

Thank you for downloading one of our ANSYS whitepapers we hope you enjoy it.

Thank you for downloading one of our ANSYS whitepapers we hope you enjoy it. Thank you! Thank you for downloading one of our ANSYS whitepapers we hope you enjoy it. Have questions? Need more information? Please don t hesitate to contact us! We have plenty more where this came from.

More information

Life time assessment and plant operation optimization based on geometry scan and strain gauge testing START/STOP optimization

Life time assessment and plant operation optimization based on geometry scan and strain gauge testing START/STOP optimization IGHEM 2014 The 10 th International conference on hydraulic efficiency measurements Itajuba, Brasil September 16 th - 18 th, 2014 XXXXXX Life time assessment and plant operation optimization based on geometry

More information

1 Introduction. Myung Sik Kim 1, Won Jee Chung 1, Jun Ho Jang 1, Chang Doo Jung 1 1 School of Mechatronics, Changwon National University, South Korea

1 Introduction. Myung Sik Kim 1, Won Jee Chung 1, Jun Ho Jang 1, Chang Doo Jung 1 1 School of Mechatronics, Changwon National University, South Korea Application of SolidWorks & AMESim - based Simulation Technique to Modeling, Cavitation, and Backflow Analyses of Trochoid Hydraulic Pump for Multi-step Transmission Myung Sik Kim 1, Won Jee Chung 1, Jun

More information

Speed and Accuracy of CFD: Achieving Both Successfully ANSYS UK S.A.Silvester

Speed and Accuracy of CFD: Achieving Both Successfully ANSYS UK S.A.Silvester Speed and Accuracy of CFD: Achieving Both Successfully ANSYS UK S.A.Silvester 2010 ANSYS, Inc. All rights reserved. 1 ANSYS, Inc. Proprietary Content ANSYS CFD Introduction ANSYS, the company Simulation

More information

Engine Calibration Process for Evaluation across the Torque- Speed Map

Engine Calibration Process for Evaluation across the Torque- Speed Map Engine Calibration Process for Evaluation across the Torque- Speed Map Brian Froelich Tara Hemami Manish Meshram Udaysinh Patil November 3, 2014 Outline : Background Objective Calibration process for torque

More information

A CFD model for orbital gerotor motor

A CFD model for orbital gerotor motor IOP Conference Series: Earth and Environmental Science A CFD model for orbital gerotor motor To cite this article: H Ding et al 2012 IOP Conf. Ser.: Earth Environ. Sci. 15 062006 View the article online

More information

SPEED-UP GEARBOX SIMULATIONS BY INTEGRATING SCORG. Dr. Christine Klier, Sahand Saheb-Jahromi, Ludwig Berger*

SPEED-UP GEARBOX SIMULATIONS BY INTEGRATING SCORG. Dr. Christine Klier, Sahand Saheb-Jahromi, Ludwig Berger* SPEED-UP GEARBOX SIMULATIONS BY INTEGRATING SCORG Dr. Christine Klier, Sahand Saheb-Jahromi, Ludwig Berger* CFD SCHUCK ENGINEERING Engineering Services in computational fluid Dynamics (CFD) 25 employees

More information

CAVITATION OPTIMIZATION FOR RESIDUAL HEAT RE- MOVAL PUMP USING ORTHOGONAL EXPERIMENTAL METHOD BASED ON PUMPLINX

CAVITATION OPTIMIZATION FOR RESIDUAL HEAT RE- MOVAL PUMP USING ORTHOGONAL EXPERIMENTAL METHOD BASED ON PUMPLINX CAVITATION OPTIMIZATION FOR RESIDUAL HEAT RE- MOVAL PUMP USING ORTHOGONAL EXPERIMENTAL METHOD BASED ON PUMPLINX Tingyun Yin, Shouqi Yuan, Yin Luo, Ji Pei, Wenjie Wang ISROMAC 2016 International Symposium

More information

Design Verification of Hydraulic Performance. for a Centrifugal Pump using. Computational Fluid Dynamics (CFD)

Design Verification of Hydraulic Performance. for a Centrifugal Pump using. Computational Fluid Dynamics (CFD) Design Verification of Hydraulic Performance for a Centrifugal Pump using Computational Fluid Dynamics (CFD) Anil S. Akole (Asst. Manager) Center for Design & Research Pentair Water India Private Limited

More information

TPV 1200 BTB. Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 156 / 1214 / E

TPV 1200 BTB. Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 156 / 1214 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES THE PRODUCTION LINE OF HANSA-TMP Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump CONTENTS General Information...

More information

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLO-CAL A portable Liquid Flow Standard FLO-CAL INSTRUMENT Data acquisition and interface tool with flow meter frequency and analog signals.

More information

Axial Channel Water Jacket Cooling

Axial Channel Water Jacket Cooling 28 November 2017 Motor-CAD Software Tutorial: Axial Channel Water Jacket Cooling Contents 1. Description... 1 2. Setting up the housing and axial channels... 2 3. Setting the water jacket fluid and flow

More information

98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98

98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98 Series Back Pressure and Type Relief VL000 Valves FIELDVUE Valve Link Fisher Controls August Bulletin.: The Series (figure ) is used for back pressure or relief applications in liquid, gas, air, and steam

More information

PARAMETRIC STUDY AND OPTIMIZATION OF CENTRIFUGAL PUMP IMPELLER BY VARYING THE DESIGN PARAMETER USING COMPUTATIONAL FLUID DYNAMICS: PART I

PARAMETRIC STUDY AND OPTIMIZATION OF CENTRIFUGAL PUMP IMPELLER BY VARYING THE DESIGN PARAMETER USING COMPUTATIONAL FLUID DYNAMICS: PART I Journal of Mechanical and Production Engineering (JMPE) ISSN 2278-3512 Vol.2, Issue 2, Sep 2012 87-97 TJPRC Pvt. Ltd., PARAMETRIC STUDY AND OPTIMIZATION OF CENTRIFUGAL PUMP IMPELLER BY VARYING THE DESIGN

More information

Flow Measurement Applications

Flow Measurement Applications Flow Measurement Applications ONICON has been a leading provider of the flow and energy measurement solutions required by the HVAC industry for the past 30 years. As the need for accurate and reliable

More information

CFD grid generation and analysis of screw compressor with variable geometry rotors

CFD grid generation and analysis of screw compressor with variable geometry rotors CFD grid generation and analysis of screw compressor with variable geometry rotors S Rane, A Kovacevic, N Stosic, M Kethidi City University London, Centre for Positive Displacement Compressor Technology,

More information

Thermal and Flow Modeling & Validation of an Exhaust Gas Particulate Matter Sensor

Thermal and Flow Modeling & Validation of an Exhaust Gas Particulate Matter Sensor Thermal and Flow Modeling & Validation of an Exhaust Gas Particulate Matter Sensor A. Lourdhusamy, B. Henderson, J. Steppan, V. Wang, J. Fitzpatrick, K. Allmendinger EmiSense Technologies, LLC Salt Lake

More information

Putting the Spin in CFD

Putting the Spin in CFD w h i t e p a p e r Putting the Spin in CFD insight S U M MARY Engineers who design equipment with rotating components need to analyze and understand the behavior of those components if they want to improve

More information

The VARIO Chemistry-pumping units with adaptive vacuum control

The VARIO Chemistry-pumping units with adaptive vacuum control The VARIO Chemistry-pumping units with adaptive vacuum control Self-optimizing vacuum for productivity and efficiency Optimize laboratory processes with VACUUBRAND VARIO technology Vacuum applications

More information

Creation and Validation of a High-Accuracy, Real-Time-Capable Mean-Value GT-POWER Model

Creation and Validation of a High-Accuracy, Real-Time-Capable Mean-Value GT-POWER Model 1 Creation and Validation of a High-Accuracy, Real-Time-Capable Mean-Value GT-POWER Model Tim Prochnau Advanced Analysis and Simulation Department Engine Group International Truck and Engine Corporation

More information

Digital Design for Centrifugal Fans

Digital Design for Centrifugal Fans Digital Design for Centrifugal Fans John Abbitt, Sam Lowry Department of Mechanical & Aerospace Engineering, University of Florida / Simerics, Inc. Abstract An objective in the curriculum in the Department

More information

CFD Simulation of a Dry Scroll Vacuum Pump Including Leakage Flows

CFD Simulation of a Dry Scroll Vacuum Pump Including Leakage Flows Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 CFD Simulation of a Dry Scroll Vacuum Pump Including Leakage Flows Jan Hesse CFX Berlin

More information

Screw-Type Flow Meter SVC

Screw-Type Flow Meter SVC Screw-Type Flow Meter SVC Description Screw-type flow meters belong to the group of positive displacement flow meters. Two measuring spindles (pos. 2) with a screw-shaped profile engage with each other.

More information

OPTIMIZATION OF AXIAL HYDRAULIC TURBINES RUNNER BLADES USING HYDRODYNAMIC SIMULATION TECHNIQUES

OPTIMIZATION OF AXIAL HYDRAULIC TURBINES RUNNER BLADES USING HYDRODYNAMIC SIMULATION TECHNIQUES Scientific Bulletin of the Politehnica University of Timisoara Transactions on Mechanics Special issue The 6 th International Conference on Hydraulic Machinery and Hydrodynamics Timisoara, Romania, October

More information

Application. Automation Studio is now compatible with Windows 8.

Application. Automation Studio is now compatible with Windows 8. March 2013 Application Automation Studio is now compatible with Windows 8. 2 Quick Access to Translations A new Translation Manager quick access button was added to the toolbar. It is also possible to

More information

Screw-Type Flow Meter SVC

Screw-Type Flow Meter SVC Screw-Type Flow Meter SVC Description Screw-type flow meters belong to the group of positive displacement flow meters. Two measuring spindles (pos. 2) with a screw-shaped profile engage with each other.

More information

Investigation of mixing chamber for experimental FGD reactor

Investigation of mixing chamber for experimental FGD reactor Investigation of mixing chamber for experimental FGD reactor Jan Novosád 1,a, Petra Danová 1 and Tomáš Vít 1 1 Department of Power Engineering Equipment, Faculty of Mechanical Engineering, Technical University

More information

Optimization of under-relaxation factors. and Courant numbers for the simulation of. sloshing in the oil pan of an automobile

Optimization of under-relaxation factors. and Courant numbers for the simulation of. sloshing in the oil pan of an automobile Optimization of under-relaxation factors and Courant numbers for the simulation of sloshing in the oil pan of an automobile Swathi Satish*, Mani Prithiviraj and Sridhar Hari⁰ *National Institute of Technology,

More information

Future Trends Part - 1 A New CAD & CAE AIES Ltd

Future Trends Part - 1 A New CAD & CAE AIES Ltd Future Trends Part - 1 A New CAD & CAE Process @ AIES Ltd Dr Ian McLuckie April 2016 ian.mcluckie@aiesl.co.uk 1 Future Trends - CAD & CAE There is a lot of discussion about how we need bigger and faster

More information

SOLUTIONS ONICON. Innovative HVAC Flow and Energy Measurement Solutions PRECISE, RELIABLE, TRUSTED

SOLUTIONS ONICON. Innovative HVAC Flow and Energy Measurement Solutions PRECISE, RELIABLE, TRUSTED Innovative HVAC Flow and Energy Measurement Solutions PRECISE, RELIABLE, TRUSTED SOLUTIONS ONICON Flow and Energy Measurement CHILLED WATER HOT WATER DOMESTIC WATER CONDENSER WATER NATURAL GAS STEAM SYSTEMS

More information

30 th Anniversary Event. New features in Opera By Nigel Atkinson, PhD. OPTIMIZER Automatically selects and manages multiple goalseeking

30 th Anniversary Event. New features in Opera By Nigel Atkinson, PhD. OPTIMIZER Automatically selects and manages multiple goalseeking FEA ANALYSIS General-purpose multiphysics design and analysis software for a wide range of applications OPTIMIZER Automatically selects and manages multiple goalseeking algorithms INTEROPERABILITY Built-in

More information

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes s 1 598 Flow sensor for liquids in DN10 25 pipes QVE3000.0xx QVE3100.0xx Vortex flow sensor made from robust red brass Output signal: DC 0 10 V or 4 20 ma Flow range: 1.8 150 l/min Used for temperature

More information

Application of SolidWorks & AMESim based Updated Simulation Technique to Back-flow Analysis of Trochoid Hydraulic Pump for Lubrication

Application of SolidWorks & AMESim based Updated Simulation Technique to Back-flow Analysis of Trochoid Hydraulic Pump for Lubrication Application of SolidWorks & AMESim based Updated Simulation Technique to Back-flow Analysis of Trochoid Hydraulic Pump for Lubrication Seung Won Jeong #, Won Jee Chung #, Man Su Kim #, Myung Sik Kim* #

More information

PRESSURE DROP AND FLOW UNIFORMITY ANALYSIS OF COMPLETE EXHAUST SYSTEMS FOR DIESEL ENGINES

PRESSURE DROP AND FLOW UNIFORMITY ANALYSIS OF COMPLETE EXHAUST SYSTEMS FOR DIESEL ENGINES PRESSURE DROP AND FLOW UNIFORMITY ANALYSIS OF COMPLETE EXHAUST SYSTEMS FOR DIESEL ENGINES André Bergel 1 Edson L. Duque 2 General Motors Global Propulsion Systems South America 12 E-mail: andrebergel84@yahoo.com.br

More information

USER S MANUAL. TurboCharger Analyser Compact

USER S MANUAL. TurboCharger Analyser Compact USER S MANUAL TurboCharger Analyser Compact USE OF THE ORIGINAL EXHAUST (TURBINE HOUSINGS) FOR BEST TEST SIMULATION SIMPLE TO WORK WITH TO REDUCE THE TESTING TIME AMPLE AND WELL-LIT WORK AREA INDEX Introduction

More information

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline

More information

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOR INTO THE INLET GUIDE VANE SYSTEM (IGV)

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOR INTO THE INLET GUIDE VANE SYSTEM (IGV) University of West Bohemia» Department of Power System Engineering NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOR INTO THE INLET GUIDE VANE SYSTEM (IGV) Publication was supported by project: Budování excelentního

More information

2008 International ANSYS Conference

2008 International ANSYS Conference 2008 International ANSYS Conference Simulation Driven Product Development using ANSYS Technology Padmesh Mandloi Rahul Kumar Samir Kadam 2008 ANSYS, Inc. All rights reserved. 1 ANSYS, Inc. Proprietary

More information

Standard Circulating Pumps

Standard Circulating Pumps Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Seal-less circulator with flanged connection. Two speed, manually adjustable to match

More information

Rotary Volumetric Machines with a Rotating Piston/Cylinder

Rotary Volumetric Machines with a Rotating Piston/Cylinder Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1998 Rotary Volumetric Machines with a Rotating Piston/Cylinder Z. Gnutek Technical University

More information

Optimisation of liquid flow in cavitation tunnel using CFD method

Optimisation of liquid flow in cavitation tunnel using CFD method Optimisation of liquid flow in cavitation tunnel using CFD method Robert Jasionowski 1,*, and Waldemar Kostrzewa 1 1 Maritime University of Szczecin, Institute of Basic Technical Sciences, 2-4 Willowa

More information

ONE DIMENSIONAL (1D) SIMULATION TOOL: GT-POWER

ONE DIMENSIONAL (1D) SIMULATION TOOL: GT-POWER CHAPTER 4 ONE DIMENSIONAL (1D) SIMULATION TOOL: GT-POWER 4.1 INTRODUCTION Combustion analysis and optimization of any reciprocating internal combustion engines is too complex and intricate activity. It

More information

Application of CFD Tools in Building Engineering and Fire Simulation

Application of CFD Tools in Building Engineering and Fire Simulation Application of CFD Tools in Building Engineering and Fire Simulation Daniel Barrero, Juan Abanto, Marcelo Reggio, J-P. Hardy, Benoît Ozell SimBuild 2004 Boulder, Colorado, USA, 4-6/8/2004 Presentation

More information

E.G.S. PILLAY ENGINEERING COLLEGE (Autonomous)

E.G.S. PILLAY ENGINEERING COLLEGE (Autonomous) E.G.S. PILLAY ENGINEERING COLLEGE (Autonomous) Approved by AICTE, New Delhi Affiliated to Anna University, Chennai Accredited by NAAC with A Grade Accredited by NBA (CSE, EEE, MECH) NAGAPATTINAM 611 002.

More information

Model Based Systems Engineering Engine Control: from concept to validation. Jan Smolders Technical Account Manager

Model Based Systems Engineering Engine Control: from concept to validation. Jan Smolders Technical Account Manager Model Based Systems Engineering Engine Control: from concept to validation Jan Smolders Technical Account Manager Table of Content Model Driven Development MiL SiL HiL Model adaptation to Real-Time Towards

More information

Reliability - Based Robust Design Optimization of Centrifugal Pump Impeller for Performance Improvement considering Uncertainties in Design Variable

Reliability - Based Robust Design Optimization of Centrifugal Pump Impeller for Performance Improvement considering Uncertainties in Design Variable Reliability - Based Robust Design Optimization of Centrifugal Pump Impeller for Performance Improvement considering Uncertainties in Design Variable M.Balamurugan Assistant Professor, Government College

More information

Hydro-Jet Vario

Hydro-Jet Vario Water-Jet Cutting Systems The wide variety of application possibilities for water-jet cutting makes it difficult to properly estimate the cost-effectiveness for all equipment variations up front. With

More information

Electronic SD1, AS 8, ASR 14, ASR 20

Electronic SD1, AS 8, ASR 14, ASR 20 Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................

More information

30 th Anniversary Event. New features in Opera By: Kevin Ward. OPTIMIZER Automatically selects and manages multiple goalseeking

30 th Anniversary Event. New features in Opera By: Kevin Ward. OPTIMIZER Automatically selects and manages multiple goalseeking FEA ANALYSIS General-purpose multiphysics design and analysis software for a wide range of applications OPTIMIZER Automatically selects and manages multiple goalseeking algorithms INTEROPERABILITY Built-in

More information

1 - "F3" means special seals for fire-resistant fluids. Omit if not required

1 - F3 means special seals for fire-resistant fluids. Omit if not required V* DOUBLE VANE PUMPS ORDERING CODE 1 - "F3" means special seals for fire-resistant fluids. Omit if not required - Pump Type: F3 VS 3 1 D 1 A A 1 3 7 VC = 1 vane pump, medium pressure application. VS =

More information

Extension and Validation of the CFX Cavitation Model for Sheet and Tip Vortex Cavitation on Hydrofoils

Extension and Validation of the CFX Cavitation Model for Sheet and Tip Vortex Cavitation on Hydrofoils Extension and Validation of the CFX Cavitation Model for Sheet and Tip Vortex Cavitation on Hydrofoils C. Lifante, T. Frank, M. Kuntz ANSYS Germany, 83624 Otterfing Conxita.Lifante@ansys.com 2006 ANSYS,

More information

Analysis of the dynamic response of pump-turbine runners- Part I: Experiment

Analysis of the dynamic response of pump-turbine runners- Part I: Experiment Analysis of the dynamic response of pump-turbine runners- Part I: Experiment A Presas 1, C Valero 1, X Huang 1, E Egusquiza 1, M Farhat 2 and F Avellan 2 1 Center for Industrial Diagnostics, Technical

More information

Vane Pump Series SDV. Fixed Displacement zp14. Catalogue HY0738-A/CH November Hydraulics. Hydraulics

Vane Pump Series SDV. Fixed Displacement zp14. Catalogue HY0738-A/CH November Hydraulics. Hydraulics SDV Fixed Displacement zp4 Catalogue HY078-/CH November 004 Contents SDV Introduction General applications instructions... Maximum speed... Pressure ratings... Minimum allowable inlet pressure... General

More information

Performance Optimization Of Screw Compressors Based On Numerical Investigation Of The Flow Behaviour In The Discharge Chamber

Performance Optimization Of Screw Compressors Based On Numerical Investigation Of The Flow Behaviour In The Discharge Chamber Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2012 Performance Optimization Of Screw Compressors Based On Numerical Investigation Of The

More information

Virtual Temperature Cycle Test (TCT) for validation of indirect Charge Air Coolers and Exhaust Gas Recirculation Coolers

Virtual Temperature Cycle Test (TCT) for validation of indirect Charge Air Coolers and Exhaust Gas Recirculation Coolers Virtual Temperature Cycle Test (TCT) for validation of indirect Charge Air Coolers and Exhaust Gas Recirculation Coolers STAR Global Conference 2014 Vienna, March 17-19 G. Apostolopoulos, R. Stauch, C.

More information

CPU COOLER OVERVIEW FREEZER SERIES

CPU COOLER OVERVIEW FREEZER SERIES CPU COOLER OVERVIEW FREEZER SERIES Freezer 11 LP Freezer 7 Pro (Rev. 2) Freezer A11 Freezer i11 CO Intel CPU Top-Blow Cooler Compact Multi-Compatible CPU Tower Cooler Compact AMD CPU Tower Cooler Compact

More information

AIChE Spring National Meeting April 25-29, 2004, New Orleans, USA

AIChE Spring National Meeting April 25-29, 2004, New Orleans, USA AIChE Spring National Meeting April 25-29, 2004, New Orleans, USA Two-Phase LNG Expanders Replace Two-Phase Joule-Thomson Valves Dr. Chen-Hwa Chiu Technology Advisor, LNG and Gas Processing ChevronTexaco,

More information

DIP. Spare parts list. Centrifugal pumps 25, 25-US, 35, 35-US, 65, 65-US Atlas Copco Construction Tools AB No c

DIP. Spare parts list. Centrifugal pumps 25, 25-US, 35, 35-US, 65, 65-US Atlas Copco Construction Tools AB No c DIP 5, 5US, 35, 35US, 65, 65US Spare parts list Centrifugal pumps 0 Atlas Copco Construction Tools AB No. 9800 5 0c 003 DIP 5, 5US, 35, 35US, 65, 65US Contents Contents General information................................................................

More information

Best Practices: Electronics Cooling. Ruben Bons - CD-adapco

Best Practices: Electronics Cooling. Ruben Bons - CD-adapco Best Practices: Electronics Cooling Ruben Bons - CD-adapco Best Practices Outline Geometry Mesh Materials Conditions Solution Results Design exploration / Optimization Best Practices Outline Geometry Solids

More information

KRAL Electronics BEM 300 and BEM 500.

KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500 Electronic units that are coordinated to KRAL flowmeters and their diverse applications. Coordinated to the flowmeters and their

More information

Applications of ICFD solver by LS-DYNA in Automotive Fields to Solve Fluid-Solid-Interaction (FSI) Problems

Applications of ICFD solver by LS-DYNA in Automotive Fields to Solve Fluid-Solid-Interaction (FSI) Problems Applications of ICFD solver by LS-DYNA in Automotive Fields to Solve Fluid-Solid-Interaction (FSI) Problems George Wang(1 ), Facundo del Pin(2), Inaki Caldichoury (2), Prince Rodriguez(3), Jason Tippie

More information

New Design Strategies for Energy Saving. Intelligent free-cooling

New Design Strategies for Energy Saving. Intelligent free-cooling New Design Strategies for Energy Saving Intelligent free-cooling Intelligent New strategies for energy saving When designing mission critical systems for processing applications or highly technological

More information

The Role of CFD in Real Life Designs

The Role of CFD in Real Life Designs white paper The Role of CFD in Real Life Designs insight SUMMARY This paper relates two heat sinks, a medical suction device, a household oven, and an industrial control valve as examples that illustrate

More information

Axial Fan Optimization Workflow

Axial Fan Optimization Workflow Axial Fan Optimization Workflow Turbomachinery design optimization using TCFD and CAESES Radek Máca, PhD Head CFD Engineer CFD Support radek.maca@cfdsupport.com Ceyhan Erdem Project and Support Engineer

More information

Bartels Micropumps. DE Seite 14

Bartels Micropumps. DE Seite 14 EN DE Seite 14 Bartels Micropumps Micropumps transporting the tiniest amounts of gases or liquids can be considered the heart of microfluidics. In many sectors they have become indispensable. Dosing lubricants,

More information

Final drive lubrication modeling

Final drive lubrication modeling Final drive lubrication modeling E. Avdeev a,b 1, V. Ovchinnikov b a Samara University, b Laduga Automotive Engineering Abstract. In this paper we describe the method, which is the composition of finite

More information

COMPUTATIONAL FLUID DYNAMICS USED IN THE DESIGN OF WATERBLAST TOOLING

COMPUTATIONAL FLUID DYNAMICS USED IN THE DESIGN OF WATERBLAST TOOLING 2015 WJTA-IMCA Conference and Expo November 2-4 New Orleans, Louisiana Paper COMPUTATIONAL FLUID DYNAMICS USED IN THE DESIGN OF WATERBLAST TOOLING J. Schneider StoneAge, Inc. Durango, Colorado, U.S.A.

More information

Heat Exchanger Efficiency

Heat Exchanger Efficiency 6 Heat Exchanger Efficiency Flow Simulation can be used to study the fluid flow and heat transfer for a wide variety of engineering equipment. In this example we use Flow Simulation to determine the efficiency

More information

Advances in Cyclonic Flow Regimes. Dr. Dimitrios Papoulias, Thomas Eppinger

Advances in Cyclonic Flow Regimes. Dr. Dimitrios Papoulias, Thomas Eppinger Advances in Cyclonic Flow Regimes Dr. Dimitrios Papoulias, Thomas Eppinger Agenda Introduction Cyclones & Hydrocyclones Modeling Approaches in STAR-CCM+ Turbulence Modeling Case 1: Air-Air Cyclone Case

More information

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline

More information

WETTING PROPERTIES OF STRUCTURED INTERFACES COMPOSED OF SURFACE-ATTACHED SPHERICAL NANOPARTICLES

WETTING PROPERTIES OF STRUCTURED INTERFACES COMPOSED OF SURFACE-ATTACHED SPHERICAL NANOPARTICLES November 20, 2018 WETTING PROPERTIES OF STRUCTURED INTERFACES COMPOSED OF SURFACE-ATTACHED SPHERICAL NANOPARTICLES Bishal Bhattarai and Nikolai V. Priezjev Department of Mechanical and Materials Engineering

More information

shop online:

shop online: Process systems Liquid ring vacuum pumps Single stage pumps 8 Alpha series single stage liquid ring vacuum pumps 9 AL series single stage liquid ring vacuum pumps 97 Two stage pumps 00 SHR series liquid

More information

Standard Circulating Pumps

Standard Circulating Pumps Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Circulating pumps with flanged connection > Applications: Drinking-water circulation

More information

Unrestricted Siemens AG 2016 Realize innovation.

Unrestricted Siemens AG 2016 Realize innovation. Automation and Standardization of CFD Workflows Dr. Wolfram Kühnel, MAHLE Behr GmbH & Co. KG Unrestricted Siemens AG 2016 Realize innovation. Outline The company Globalization Standardization Automation

More information

Advanced Applications of STAR- CCM+ in Chemical Process Industry Ravindra Aglave Director, Chemical Process Industry

Advanced Applications of STAR- CCM+ in Chemical Process Industry Ravindra Aglave Director, Chemical Process Industry Advanced Applications of STAR- CCM+ in Chemical Process Industry Ravindra Aglave Director, Chemical Process Industry Outline Notable features released in 2013 Gas Liquid Flows with STAR-CCM+ Packed Bed

More information

Validation of CFD Simulation with Scaled Physical Model of Tailings Dissipation Boxes

Validation of CFD Simulation with Scaled Physical Model of Tailings Dissipation Boxes Validation of CFD Simulation with Scaled Physical Model of Tailings Dissipation Boxes José Facusse Ingeniero Mecánico Daniel Manzo Ingeniero Hidráulico PRESENTATION TOPICS Company Overview; Problem Description;

More information

CFD Modeling of a Radiator Axial Fan for Air Flow Distribution

CFD Modeling of a Radiator Axial Fan for Air Flow Distribution CFD Modeling of a Radiator Axial Fan for Air Flow Distribution S. Jain, and Y. Deshpande Abstract The fluid mechanics principle is used extensively in designing axial flow fans and their associated equipment.

More information

Adjoint Solver Workshop

Adjoint Solver Workshop Adjoint Solver Workshop Why is an Adjoint Solver useful? Design and manufacture for better performance: e.g. airfoil, combustor, rotor blade, ducts, body shape, etc. by optimising a certain characteristic

More information

Modeling the Cooling Air Flow in an Electric Generator

Modeling the Cooling Air Flow in an Electric Generator Modeling the Cooling Air Flow in an Electric Generator 6 th OpenFOAMworkshop Pirooz Moradnia, Håkan Nilsson PennState University, USA 2011-06-14 Pirooz Moradnia, Chalmers/ Applied Mechanics/ Fluid Dynamics

More information

WinPump. IMO AB Pump Selection Program Manual from version General. 1 User interface Pump selection _ 3

WinPump. IMO AB Pump Selection Program Manual from version General. 1 User interface Pump selection _ 3 WinPump IMO AB Pump Selection Program Manual from version 3.7.11 1 User interface 2 2.0 Pump selection _ 3 2.1 By operating data 3 2.2 By text entry 3 2.3 By designation search 4 2.4 By Pump family 4 3

More information

PARAMETER LIST DELOMATIC 4, DM-4 GAS CHP CONTROLLER

PARAMETER LIST DELOMATIC 4, DM-4 GAS CHP CONTROLLER PARAMETER LIST DELOMATIC 4, DM-4 GAS CHP CONTROLLER Document no.: 4189340659A SW version 1.33.2 and later Table of contents 1. ABOUT THIS DOCUMENT... 4 GENERAL PURPOSE... 4 INTENDED USERS... 4 CONTENTS/OVERALL

More information

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners Page 1 of 184 Software for the simulation of refrigeration equipment and air conditioners Index Software for the simulation of refrigeration equipment and air conditioners... 1 : application description

More information

Open source software tools for powertrain optimisation

Open source software tools for powertrain optimisation Open source software tools for powertrain optimisation Paolo Geremia Eugene de Villiers TWO-DAY MEETING ON INTERNAL COMBUSTION ENGINE SIMULATIONS USING OPENFOAM TECHNOLOGY 11-12 July, 2011 info@engys.eu

More information

CFD Simulation of a Twin Screw Expander including Leakage Flows

CFD Simulation of a Twin Screw Expander including Leakage Flows Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 CFD Simulation of a Twin Screw Expander including Leakage Flows Rainer Andres CFX Berlin

More information

Fluid Structure Interaction Modeling for Geroler Motor Performance Prediction using FEA and CFD Coupled Approach

Fluid Structure Interaction Modeling for Geroler Motor Performance Prediction using FEA and CFD Coupled Approach flotek.g 2017- Innovative Solutions in Flow Measurement and Control - Oil, Water and Gas August 28-30, 2017, FCRI, Palakkad, Kerala, India Fluid Structure Interaction Modeling for Geroler Motor Performance

More information

Operating instructions Vortex flow meter. SVxxx / / 2015

Operating instructions Vortex flow meter. SVxxx / / 2015 Operating instructions Vortex flow meter SVxxx4 80226711 / 00 06 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...3 3 Functions and features...4

More information

RA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols

RA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols /2.9 Gear Pump Model G2 (Series X For Flange Mounting with SE threaded Ports s to 22... 6 PSI (2 bar....7 in /rev. (22. cm /rev. /2.9 eplaces: 2.92 New principle of sealing the pump body, increases service

More information

EUROPEAN PATENT OFFICE U.S. PATENT AND TRADEMARK OFFICE CPC NOTICE OF CHANGES 554 DATE: AUGUST 1, 2018 PROJECT MP0228

EUROPEAN PATENT OFFICE U.S. PATENT AND TRADEMARK OFFICE CPC NOTICE OF CHANGES 554 DATE: AUGUST 1, 2018 PROJECT MP0228 EUROPEAN PATENT OFFICE U.S. PATENT AND TRADEMARK OFFICE CPC NOTICE OF CHANGES 554 PROJECT MP0228 The following classification changes will be effected by this Notice of Changes: Action Subclass Group(s)

More information

Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves

Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves Case Study Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves Botlek Tank Terminal Case Study - 26th April 2013 Botlek Tank Terminal Case Study - 26th April 2013

More information