1 DVH Estimates Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience Karen Chin Snyder, MS, DABR AAMD Region V Meeting October 4, 2014

2 Disclosures The Department of Radiation Oncology at Henry Ford Hospital has a research agreement with Varian Medical Systems. The speaker has received speakers honoraria from Varian Medical Systems

3 Varian Medical Systems Fair Balance Safety Statement INTENDED USE STATEMENT Varian Medical Systems linear accelerators are intended to provide stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body where radiation treatment is indicated. SAFETY Radiation treatments may cause side effects that can vary depending on the part of the body being treated. The most frequent ones are typically temporary and may include, but are not limited to, irritation to the respiratory, digestive, urinary or reproductive systems, fatigue, nausea, skin irritation, and hair loss. In some patients, they can be severe. Treatment sessions may vary in complexity and time. Radiation treatment is not appropriate for all cancers. Medical Advice Disclaimer Varian as a medical device manufacturer cannot and does not recommend specific treatment approaches. Individual treatment results may vary. For more information, visit MyVarian.com. FOR HEALTH CARE PROFESSIONALS ONLY

4 Why use Knowledge Based Models? Inverse Planning Variability Dependent on Planner s skill Balancing clinical objectives Iterative process that can be time consuming

5 RapidPlan TM Varian s Solution for Knowledge-Based Planning DVH Estimation Model Tumor Site Specific Trained from existing plans that have accepted OAR tradeoffs Uses principal component analysis for each OAR Different sub-volumes use different DVH estimation Automatic objective generation DVH estimates Automatic objectives The estimated DVH PC coefficient From the structure set of current plan

6 Basic Steps in Creating a KB Model Add Plans to the Model Train and Verify the Model Validate the Model

7 Basic Steps in Creating a KB Model Training Data Set Add Plans to the Model Train and Verify the Model Validation Data Set Validate the Model

8 Adding Plans to the Model Add Plans to the Model Geometry of Targets & OARs Plan Quality Treatment Technique Dose Prescription

9 Adding Plans to the Model Add Plans to the Model Geometry of Targets & OARs Plan Quality Treatment Technique Dose Prescription

10 Geometry of Targets and OARs - Size, Contouring and Physiology of OARs How do you treat at your clinic? Example: Rectum empty, bladder full and PTV expansions - change the overlap region between the OARs and Target - range of volumes of OARs in the model ie, full rectum as outlier

11 Geometry of Targets and OARs - Position of OARs relative to target Amount of Overlap Example: HN: amount of overlap with parotids Lung: RTOG 0915, max doses less than Rx dose. No overlap. - Differing volumes in the in-field region, all scenarios

12 Geometry of Targets and OARs - Position of OARs relative to target Distance of Target to OARs - Differing out-of-field volumes OAR s proximity to Spinal Cord

13 Geometry of Targets and OARs - Size, Contouring and Physiology of OARs Which OARs do you want the model to support? Example: Stomach and Brachial Plexus - Typical location of target compared to extreme locations - Need sufficient number of cases to train the model to give an estimate - OARs can be included without an estimation (fixed objective)

14 Adding Plans to the Model Add Plans to the Model Geometry of Targets & OARs Plan Quality Treatment Technique Dose Prescription

15 Treatment Technique - VMAT, IMRT, both - Gantry Angles - Non-coplanar, coplanar Beam geometry Important in Structure Volume Partitioning - Different out-of-field/in-field/ leaf-transmission and target overlap volumes Target overlap region In-field region Transversal view Leaf-transmission region Out-of-field region Image courtesy of Esa Kuusela, Varian Medical Systemes

16 Adding Plans to the Model Add Plans to the Model Geometry of Targets & OARs Plan Quality Treatment Technique Dose Prescription

17 Dose Prescription - Simultaneous Boost (SIB) - Attach multiple PTVs to the structure - Differing Dose Prescriptions - Scaling of doses - Not ideal for different fractionation schemes S.H. Benedict, K.M. Yenice, D. Followill, et al. Stereotactic body radiation therapy: The report of AAPM Task Group 101 Med Phys, 37 (2010), pp

18 Adding Plans to the Model Add Plans to the Model Geometry of Targets & OARs Plan Quality Treatment Technique Dose Prescription

19 Plan Quality Physician Preferred Dose Distributions PTV coverage - NTO used, Shoulder of DVH, allowable hot spot OAR Sparing Example: Rib sparing in HFHS Lung SBRT Model

20 How Many Plans to Include in the Model Complexity of model, and what you want it to include - Prostate ~40, Prostate w/ LN ~ 70, HN SIB ~ 116, SBRT Lung = 105 Overlap of Data points - Basically the same plan/location - Can always add new interesting cases to the model, will need to re-validate

21 Basic Steps in Creating a KB Model Add Plans to the Model Train and Verify the Model Validate the Model

22 Train and Verify the Model Train the Model Re-Extract Identify Outliers Add Similar Plans Re-plan Re-contour Dosimetric Geometric Remove Plan Evaluate if Plan is Appropriate Neither?

23 DVH Tool Validation Tools - OAR of each training patient and corresponding estimate Estimate

24 Training Log - Outlier Summary and Metrics - Statistics Summary Validation Tools

25 Validation Tools Regression Plot - DVH PC1 vs Geometric Distribution PC1 2 Std Devs Model Fit

26 Training log Identifying Geometric Outliers - Cook s Distance (CD) : indicates influential point, alerts you when >4 - Modified Z score (mz) 4 : difference between individual and mean Regression Plot: DVH PC1 vs Geometric Distribution PC1 Contouring issues: partially contoured structure

27 Training log Identifying Dosimetric Outliers - Studentized Residual (SR) : measures difference between original and estimated data, threshold of >3 will alert - Areal difference of estimate (da) difference in area between estimated and actual DVH Residual Plot: DVH PC vs Estimated DVH PC1 Original Plan is Higher than Estimate Example: Atypical tradeoff between OARs Original Plan is lower than Estimate

28 Training log Neither? - Cook s Distance (CD) : indicates influential point - Studentized Residual (SR) : measures difference between original and estimated data Regression Plot: DVH PC1 vs Geometric Distribution PC1 Need more data points to fill in regression plot

29 Goodness- of-fit Statistics Overfitting - Chi square: range 0-1, want to be closer to 1 - Coefficient of determination: close to 1

30 Basic Steps in Creating a KB Model Add Plans to the Model Train and Verify the Model Validate the Model

31 Validate the Model The Model Patient Plan Model Estimate Final Dose Calc Estimated Plan Validate DVH Estimation Validate Automatic Priorities Validate the Model

32 Patient Plan vs Estimate For a particular patient geometry, is your model able to give you a good estimate? Validate the DVH Estimation - Do you need to go back and evaluate your training set/re-train model?

33 Model Estimate vs Estimated Plan After optimization and final calculation Validate the Objectives - Are the estimated priorities able to achieve the estimated DVH?

34 Patient Plan vs Estimated Plan How well is your model performing? Are you obtaining clinically acceptable plans? Validate the Overall Model - Use a good range of geometries - Are there exceptions/limitations after validation?

35 Limitations in our Model Issue in cases where the PTV abuts the heart Max heart dose is 34Gy, 95% of PTV to receive 48Gy Needs additional user modification in order to meet the OAR max dose constraint Plan may not meet other planning criteria, GI, 99% PTV coverage, max dose from PTV+2cm Not supported in the current model Fixed PTV objectives Not many patient cases

36 Published Models - Varian Provided Models Publication and Sharing - Intended usage and applicability to your clinic - You can modify Varian Models - Need to be independently validated by you before application to clinic - Easily share models

37 Using a RapidPlan Model Integrated part of the Photon Optimizer - Choose the Model - Match OARs to Model Structure - Match PTV to PTV, and set Target Dose - Generate Estimates and Objectives and optimize. Similar to applying a fixed objective template, but with the knowledge of patient geometry and experience of previous planners

38 Knowledge based models Conclusion - Share knowledge with DVH estimation and automatic objective creation - 3 basic steps in creating your own model - You can create your own models or modify existing models How KB Models can help you - Quality Control of IMRT plans - Standardization - Automation - Inter-institutional sharing

39 Thank You The KB Team at HF: Indrin Chetty, PhD Ajlouni Munther, MD Salim Siddiqui, MD, PhD Jinkoo Kim, PhD Anne Reding, CMD Corey Fraser, CMD Varian: Helen Phillips, Esa Kuusela

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery Lei Ren, Ph.D. Duke University Medical Center 2016 AAPM 58 th annual meeting, Educational Course, Therapy Track Disclosure I have

More information

7/29/2017. Making Better IMRT Plans Using a New Direct Aperture Optimization Approach. Aim of Radiotherapy Research. Aim of Radiotherapy Research

7/29/2017. Making Better IMRT Plans Using a New Direct Aperture Optimization Approach. Aim of Radiotherapy Research. Aim of Radiotherapy Research Making Better IMRT Plans Using a New Direct Aperture Optimization Approach Dan Nguyen, Ph.D. Division of Medical Physics and Engineering Department of Radiation Oncology UT Southwestern AAPM Annual Meeting

More information

Coverage based treatment planning to accommodate organ deformable motions and contouring uncertainties for prostate treatment. Huijun Xu, Ph.D.

Coverage based treatment planning to accommodate organ deformable motions and contouring uncertainties for prostate treatment. Huijun Xu, Ph.D. Coverage based treatment planning to accommodate organ deformable motions and contouring uncertainties for prostate treatment Huijun Xu, Ph.D. Acknowledgement and Disclosure Dr. Jeffrey Siebers Dr. DJ

More information

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016 Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France Sunday 17 July 2016 AGENDA 1. Introduction 2. Material 3. Optimization process 4. Results 5. Comments 6. Conclusion

More information

Auto-Segmentation Using Deformable Image Registration. Disclosure. Objectives 8/4/2011

Auto-Segmentation Using Deformable Image Registration. Disclosure. Objectives 8/4/2011 Auto-Segmentation Using Deformable Image Registration Lei Dong, Ph.D. Dept. of Radiation Physics University of Texas MD Anderson Cancer Center, Houston, Texas AAPM Therapy Educational Course Aug. 4th 2011

More information

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application Monaco VMAT The Next Generation in IMRT/VMAT Planning Paulo Mathias Customer Support TPS Application 11.05.2011 Background What is Monaco? Advanced IMRT/VMAT treatment planning system from Elekta Software

More information

radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li NCAAPM Spring Meeting 2010 Madison, WI

radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li NCAAPM Spring Meeting 2010 Madison, WI GPU-Accelerated autosegmentation for adaptive radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li agodley@mcw.edu NCAAPM Spring Meeting 2010 Madison, WI Overview Motivation Adaptive

More information

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC GPU applications in Cancer Radiation Therapy at UCSD Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC Conventional Radiotherapy SIMULATION: Construciton, Dij Days PLANNING:

More information

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF Page 1 Quality Assurance of IMRT Delivery Systems - Siemens Lynn J. Verhey, Ph.D. Professor and Vice-Chair UCSF Dept. of Radiation Oncology AAPM 22 Annual Meeting, Montreal Acknowledgments Ping Xia, Ph.D.,

More information

The MSKCC Approach to IMRT. Outline

The MSKCC Approach to IMRT. Outline The MSKCC Approach to IMRT Spiridon V. Spirou, PhD Department of Medical Physics Memorial Sloan-Kettering Cancer Center New York, NY Outline Optimization Field splitting Delivery Independent verification

More information

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them Dose Distributions George Starkschall, Ph.D. Department of Radiation Physics U.T. M.D. Anderson Cancer Center Purpose To familiarize the resident with dose distributions and the factors that affect them

More information

IMRT site-specific procedure: Prostate (CHHiP)

IMRT site-specific procedure: Prostate (CHHiP) IMRT site-specific procedure: Prostate (CHHiP) Scope: To provide site specific instructions for the planning of CHHIP IMRT patients Responsibilities: Radiotherapy Physicists, HPC Registered Therapy Radiographers

More information

Basic Radiation Oncology Physics

Basic Radiation Oncology Physics Basic Radiation Oncology Physics T. Ganesh, Ph.D., DABR Chief Medical Physicist Fortis Memorial Research Institute Gurgaon Acknowledgment: I gratefully acknowledge the IAEA resources of teaching slides

More information

CONTOURING ACCURACY. What Have We Learned? And Where Do We Go From Here? BEN NELMS, PH.D. AUGUST 15, 2016

CONTOURING ACCURACY. What Have We Learned? And Where Do We Go From Here? BEN NELMS, PH.D. AUGUST 15, 2016 CONTOURING ACCURACY What Have We Learned? And Where Do We Go From Here? BEN NELMS, PH.D. AUGUST 15, 2016 FIRST THINGS FIRST Happy Medical Dosimetrist s Week! OUTLINE 1. Objectives 2. The importance of

More information

Monaco Concepts and IMRT / VMAT Planning LTAMON0003 / 3.0

Monaco Concepts and IMRT / VMAT Planning LTAMON0003 / 3.0 and IMRT / VMAT Planning LTAMON0003 / 3.0 and Planning Objectives By the end of this presentation you can: Describe the cost functions in Monaco and recognize their application in building a successful

More information

How would, or how does, the patient position (chin extended) affect your beam arrangement?

How would, or how does, the patient position (chin extended) affect your beam arrangement? 1 Megan Sullivan Clinical Practicum II Parotid Lab July 29, 2016 PLAN 1: IPSILATERAL WEDGE PAIR TECHNIQUE The ipsilateral wedge pair technique consisted of an anterior oblique field at 45 degrees and a

More information

Dosimetric impact of the 160 MLC on head and neck IMRT treatments

Dosimetric impact of the 160 MLC on head and neck IMRT treatments JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 6, 2014 Dosimetric impact of the 160 MLC on head and neck IMRT treatments Prema Rassiah-Szegedi, a Martin Szegedi, Vikren Sarkar, Seth Streitmatter,

More information

iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration

iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration The iplan Contouring Workstation offers unique and innovative capabilities for faster contouring and consistent segmentation

More information

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT Volumetric Modulated Arc Therapy - Clinical Implementation Daliang Cao, PhD, DABR Swedish Cancer Institute, Seattle, WA Acknowledgement David M. Shepard, Ph.D. Muhammad K. N. Afghan, Ph.D. Fan Chen, Ph.D.

More information

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology VALIDATION OF DIR Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology Overview Basics: Registration Framework, Theory Discuss Validation techniques Using Synthetic CT data & Phantoms What metrics to

More information

Optimization in Brachytherapy. Gary A. Ezzell, Ph.D. Mayo Clinic Scottsdale

Optimization in Brachytherapy. Gary A. Ezzell, Ph.D. Mayo Clinic Scottsdale Optimization in Brachytherapy Gary A. Ezzell, Ph.D. Mayo Clinic Scottsdale Outline General concepts of optimization Classes of optimization techniques Concepts underlying some commonly available methods

More information

Current state of multi-criteria treatment planning

Current state of multi-criteria treatment planning Current state of multi-criteria treatment planning June 11, 2010 Fall River NE AAPM meeting David Craft Massachusetts General Hospital Talk outline - Overview of optimization - Multi-criteria optimization

More information

Photon beam dose distributions in 2D

Photon beam dose distributions in 2D Photon beam dose distributions in 2D Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2014 Acknowledgments! Narayan Sahoo PhD! Richard G Lane (Late) PhD 1 Overview! Evaluation

More information

Using a research real-time control interface to go beyond dynamic MLC tracking

Using a research real-time control interface to go beyond dynamic MLC tracking in partnership with Using a research real-time control interface to go beyond dynamic MLC tracking Dr. Simeon Nill Joint Department of Physics at The Institute of Cancer Research and the Royal Marsden

More information

Title: Toward Truly Optimal IMRT Dose Distribution: Inverse Planning with Voxel- Specific Penalty

Title: Toward Truly Optimal IMRT Dose Distribution: Inverse Planning with Voxel- Specific Penalty Type of the article: Original article Title: Toward Truly Optimal IMRT Dose Distribution: Inverse Planning with Voxel- Specific Penalty Authors: Pavel Lougovski (1), Jordan LeNoach (1), Lei Zhu (1), Yunzhi

More information

Radiation therapy treatment plan optimization

Radiation therapy treatment plan optimization H. Department of Industrial and Operations Engineering The University of Michigan, Ann Arbor, Michigan MOPTA Lehigh University August 18 20, 2010 Outline 1 Introduction Radiation therapy delivery 2 Treatment

More information

Image Guidance and Beam Level Imaging in Digital Linacs

Image Guidance and Beam Level Imaging in Digital Linacs Image Guidance and Beam Level Imaging in Digital Linacs Ruijiang Li, Ph.D. Department of Radiation Oncology Stanford University School of Medicine 2014 AAPM Therapy Educational Course Disclosure Research

More information

A Fully-Automated Intensity-Modulated Radiation Therapy Planning System

A Fully-Automated Intensity-Modulated Radiation Therapy Planning System A Fully-Automated Intensity-Modulated Radiation Therapy Planning System Shabbir Ahmed, Ozan Gozbasi, Martin Savelsbergh Georgia Institute of Technology Ian Crocker, Tim Fox, Eduard Schreibmann Emory University

More information

8/3/2017. Contour Assessment for Quality Assurance and Data Mining. Objective. Outline. Tom Purdie, PhD, MCCPM

8/3/2017. Contour Assessment for Quality Assurance and Data Mining. Objective. Outline. Tom Purdie, PhD, MCCPM Contour Assessment for Quality Assurance and Data Mining Tom Purdie, PhD, MCCPM Objective Understand the state-of-the-art in contour assessment for quality assurance including data mining-based techniques

More information

An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors

An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 13, NUMBER 4, 2012 An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors

More information

ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD. Moe Siddiqui, April 08, 2017

ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD. Moe Siddiqui, April 08, 2017 ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD Moe Siddiqui, April 08, 2017 Agenda Background IRCU 50 - Disclaimer - Uncertainties Robust optimization Use Cases Lung Robust 4D

More information

CHAPTER 9 INFLUENCE OF SMOOTHING ALGORITHMS IN MONTE CARLO DOSE CALCULATIONS OF CYBERKNIFE TREATMENT PLANS: A LUNG PHANTOM STUDY

CHAPTER 9 INFLUENCE OF SMOOTHING ALGORITHMS IN MONTE CARLO DOSE CALCULATIONS OF CYBERKNIFE TREATMENT PLANS: A LUNG PHANTOM STUDY 148 CHAPTER 9 INFLUENCE OF SMOOTHING ALGORITHMS IN MONTE CARLO DOSE CALCULATIONS OF CYBERKNIFE TREATMENT PLANS: A LUNG PHANTOM STUDY 9.1 INTRODUCTION 9.1.1 Dose Calculation Algorithms Dose calculation

More information

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays Sotiri Stathakis Outline Why IMRT/VMAT QA AAPM TG218 UPDATE Tolerance Limits and Methodologies for IMRT Verification QA Common sources

More information

A hybrid framework for optimizing beam angles in radiation therapy planning

A hybrid framework for optimizing beam angles in radiation therapy planning A hybrid framework for optimizing beam angles in radiation therapy planning Gino J. Lim and Laleh Kardar and Wenhua Cao December 29, 2013 Abstract The purpose of this paper is twofold: (1) to examine strengths

More information

Tumor motion during liver SBRT

Tumor motion during liver SBRT Tumor motion during liver SBRT - projects at Aarhus University Hospital - Per Poulsen, Esben Worm, Walther Fledelius, Morten Høyer Aarhus University Hospital, Denmark SBRT: Stereotactic Body Radiation

More information

FAST, precise. qa software

FAST, precise. qa software qa software FAST, precise Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, rotational or brachytherapy plans no film, no phantoms, no linac

More information

A Fully-Automated Intensity-Modulated Radiation Therapy Planning System

A Fully-Automated Intensity-Modulated Radiation Therapy Planning System A Fully-Automated Intensity-Modulated Radiation Therapy Planning System Shabbir Ahmed, Ozan Gozbasi, Martin Savelsbergh Georgia Institute of Technology Tim Fox, Ian Crocker, Eduard Schreibmann Emory University

More information

arxiv: v3 [physics.med-ph] 6 Dec 2011

arxiv: v3 [physics.med-ph] 6 Dec 2011 Multicriteria VMAT optimization David Craft, Dualta McQuaid, Jeremiah Wala, Wei Chen, Ehsan Salari, Thomas Bortfeld December 5, 2011 arxiv:1105.4109v3 [physics.med-ph] 6 Dec 2011 Abstract Purpose: To make

More information

Accounting for Large Geometric Changes During Radiotherapy. Disclosures. Current Generation DIR in RT 8/3/2016

Accounting for Large Geometric Changes During Radiotherapy. Disclosures. Current Generation DIR in RT 8/3/2016 Accounting for Large Geometric Changes During Radiotherapy Geoff Hugo, Ph.D. Department of Radiation Oncology Virginia Commonwealth University, Richmond, Virginia, USA Disclosures Research support: Philips

More information

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 ICARO Vienna April 27-29 2009 Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 M. Saiful Huq, Ph.D., Professor and Director, Dept. of Radiation

More information

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE QA SOFTWARE FAST, PRECISE Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, VMAT, SRS and brachytherapy plans no film, no phantoms, no linac

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT 3 ADVANCING CANCER TREATMENT SUPPORTING CLINICS WORLDWIDE RaySearch is advancing cancer treatment through pioneering software. We believe software has un limited potential, and that it is now the driving

More information

Two Effective Heuristics for Beam Angle Optimization in Radiation Therapy

Two Effective Heuristics for Beam Angle Optimization in Radiation Therapy Two Effective Heuristics for Beam Angle Optimization in Radiation Therapy Hamed Yarmand, David Craft Department of Radiation Oncology Massachusetts General Hospital and Harvard Medical School, Boston,

More information

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy Data ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy The ModuLeaf Mini Multileaf

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT The RayPlan treatment planning system makes proven, innovative RayStation technology accessible to clinics that need a cost-effective and streamlined solution. Fast, efficient and straightforward to use,

More information

Radiotherapy Plan Competition TomoTherapy Planning System. Dmytro Synchuk. Ukrainian Center of TomoTherapy, Kirovograd, Ukraine

Radiotherapy Plan Competition TomoTherapy Planning System. Dmytro Synchuk. Ukrainian Center of TomoTherapy, Kirovograd, Ukraine Radiotherapy Plan Competition 2016 TomoTherapy Planning System Dmytro Synchuk Ukrainian Center of TomoTherapy, Kirovograd, Ukraine Beam Geometry 6MV fan beam 3 jaw options 1.0, 2.5 and 5 cm 64 leaves binary

More information

Analysis of RapidArc optimization strategies using objective function values and dose-volume histograms

Analysis of RapidArc optimization strategies using objective function values and dose-volume histograms JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 11, NUMBER 1, WINTER 2010 Analysis of RapidArc optimization strategies using objective function values and dose-volume histograms Mike Oliver, a Isabelle

More information

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays Your Most Valuable QA and Dosimetry Tools THE GOLD STANDARD FOR 2D ARRAYS The MapCHECK 2 is the world s most selected independent 2D measurement array.

More information

Use of Deformable Image Registration in Radiation Therapy. Colin Sims, M.Sc. Accuray Incorporated 1

Use of Deformable Image Registration in Radiation Therapy. Colin Sims, M.Sc. Accuray Incorporated 1 Use of Deformable Image Registration in Radiation Therapy Colin Sims, M.Sc. Accuray Incorporated 1 Overview of Deformable Image Registration (DIR) Algorithms that can deform one dataset to another have

More information

Interactive Treatment Planning in Cancer Radiotherapy

Interactive Treatment Planning in Cancer Radiotherapy Interactive Treatment Planning in Cancer Radiotherapy Mohammad Shakourifar Giulio Trigila Pooyan Shirvani Ghomi Abraham Abebe Sarah Couzens Laura Noreña Wenling Shang June 29, 212 1 Introduction Intensity

More information

TRAJECTORY- BASED TREATMENT PLANNING AND DELIVERY FOR CRANIAL RADIOSURGERY

TRAJECTORY- BASED TREATMENT PLANNING AND DELIVERY FOR CRANIAL RADIOSURGERY TRAJECTORY- BASED TREATMENT PLANNING AND DELIVERY FOR CRANIAL RADIOSURGERY JAMES ROBAR, PHD, FCCPM LEE MACDONALD, MSC CHRISTOPHER THOMAS, PHD, MCCPM DALHOUSIE UNIVERSITY, CANADA CLASS SOLUTIONS IN SRS/SRT

More information

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT Anand P Santhanam Assistant Professor, Department of Radiation Oncology OUTLINE Adaptive radiotherapy for head and

More information

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers Krista Chytyk MSc student Supervisor: Dr. Boyd McCurdy Introduction The objective of cancer radiotherapy

More information

The Dose Junction Issue Associated with Photon Beams for Large Volume Radiation Therapy and the Sensitivity to Set-up Error

The Dose Junction Issue Associated with Photon Beams for Large Volume Radiation Therapy and the Sensitivity to Set-up Error Research Article imedpub Journals http://www.imedpub.com/ Journal of Medical Physics and Applied Sciences The Dose Junction Issue Associated with Photon Beams for Large Volume Radiation Therapy and the

More information

State-of-the-Art IGRT

State-of-the-Art IGRT in partnership with State-of-the-Art IGRT Exploring the Potential of High-Precision Dose Delivery and Real-Time Knowledge of the Target Volume Location Antje-Christin Knopf IOP Medical Physics Group Scientific

More information

An Automatic Approach for Satisfying Dose-Volume Constraints in Linear Fluence Map Optimization for IMPT

An Automatic Approach for Satisfying Dose-Volume Constraints in Linear Fluence Map Optimization for IMPT Journal of Cancer Therapy, 2014, 5, 198-207 Published Online February 2014 (http://www.scirp.org/journal/jct) http://dx.doi.org/10.4236/jct.2014.52025 An Automatic Approach for Satisfying Dose-Volume Constraints

More information

Comparison of 3D and 2D gamma passing rate criteria for detection sensitivity to IMRT delivery errors

Comparison of 3D and 2D gamma passing rate criteria for detection sensitivity to IMRT delivery errors Received: 13 February 2018 Revised: 7 May 2018 Accepted: 24 May 2018 DOI: 10.1002/acm2.12389 RADIATION ONCOLOGY PHYSICS Comparison of 3D and 2D gamma passing rate criteria for detection sensitivity to

More information

Dose Calculation and Optimization Algorithms: A Clinical Perspective

Dose Calculation and Optimization Algorithms: A Clinical Perspective Dose Calculation and Optimization Algorithms: A Clinical Perspective Daryl P. Nazareth, PhD Roswell Park Cancer Institute, Buffalo, NY T. Rock Mackie, PhD University of Wisconsin-Madison David Shepard,

More information

Secondary 3D Dose QA Fully Automated using MOSAIQ's IQ Engine. MOSAIQ User Meeting May Antwerp

Secondary 3D Dose QA Fully Automated using MOSAIQ's IQ Engine. MOSAIQ User Meeting May Antwerp Secondary 3D Dose QA Fully Automated using MOSAIQ's IQ Engine MOSAIQ User Meeting May 31 2013 - Antwerp Contents Project goal and collaboration Secondary 3D Dose QA project justification Secondary 3D Dose

More information

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays Your Most Valuable QA and Dosimetry Tools THE GOLD STANDARD FOR 2D ARRAYS The MapCHECK 2 is the world s most selected independent 2D measurement array.

More information

Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC)

Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC) Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC) NCCAAPM Spring Meeting May 3, 2013 Introduction FFF background Project

More information

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2015 Evaluation of 3D Gamma index calculation implemented

More information

A Mimetic Algorithm for Simultaneous Multileaf Collimator Aperture Shape and Dosimetric Optimization in CyberKnife Robotic Radiosurgery

A Mimetic Algorithm for Simultaneous Multileaf Collimator Aperture Shape and Dosimetric Optimization in CyberKnife Robotic Radiosurgery A Mimetic Algorithm for Simultaneous Multileaf Collimator Aperture Shape and Dosimetric Optimization in CyberKnife Robotic Radiosurgery Matthew R. Witten, Owen C. Clancey, Division of Radiation Oncology,

More information

arxiv: v1 [physics.med-ph] 26 Oct 2009

arxiv: v1 [physics.med-ph] 26 Oct 2009 arxiv:0910.4934v1 [physics.med-ph] 26 Oct 2009 On the tradeoff between treatment time and plan quality in rotational arc radiation delivery 1. Introduction David Craft and Thomas Bortfeld Department of

More information

Transitioning from pencil beam to Monte Carlo for electron dose calculations

Transitioning from pencil beam to Monte Carlo for electron dose calculations Transitioning from pencil beam to Monte Carlo for electron dose calculations Jessie Huang-Vredevoogd (jyhuang4@wisc.edu) University of Wisconsin NCC AAPM October 12, 2019 1 Topics to cover Background RayStation

More information

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS Tomotherapy Physics Machine Twinning and Quality Assurance Emilie Soisson, MS Tomotherapy at UW- Madison Treating for nearly 5 years Up to ~45 patients a day on 2 tomo units Units twinned to facilitate

More information

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS ON SMALL FIELDS AND INTENSITY MODULATED RADIATION THERAPY by Cindy D. Smith A Thesis Submitted to the

More information

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending 3DVH : On The Accuracy Of The Planned Dose Perturbation Algorithm SUN NUCLEAR corporation Your Most Valuable QA and Dosimetry Tools *Patent Pending introduction State-of-the-art IMRT QA of static gantry

More information

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear Delta 4 PT True Volumetric Pre-treatment Verification The difference is clear ScandiDos innovators in advanced volumetric dosimetry solutions ScandiDos ScandiDos is the innovative company that introduced

More information

1. Learn to incorporate QA for surface imaging

1. Learn to incorporate QA for surface imaging Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures*** 1. Learn to incorporate QA for surface imaging into current QA procedures for IGRT. 2. Understand

More information

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC New Technology in Radiation Oncology James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC Technology s s everywhere From the imaging chain To the planning system To the linac To QA..it..it

More information

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA Jennifer R. Clark, M.S., DABR Conflict of Interest Statement: I am an employee of Sun Nuclear Corporation Outline: Platform overview

More information

A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study

A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study Indrin J. Chetty, a) Mihaela Rosu, Neelam Tyagi, Lon H. Marsh, Daniel

More information

Evaluation of fluence-based dose delivery incorporating the spatial variation of dosimetric leaf gap (DLG)

Evaluation of fluence-based dose delivery incorporating the spatial variation of dosimetric leaf gap (DLG) JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 1, 2016 Evaluation of fluence-based dose delivery incorporating the spatial variation of dosimetric leaf gap (DLG) Lalith K. Kumaraswamy,

More information

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1 TPS COMMISSIONING Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1 Conflicts of interest Court receives funding from NIH, CPIRT, Varian and Elekta 4/3/2017 2 Resources your first

More information

A Genetic Algorithm approach to Full Beam Configuration Inverse Planning in Coplanar Radiotherapy

A Genetic Algorithm approach to Full Beam Configuration Inverse Planning in Coplanar Radiotherapy A Genetic Algorithm approach to Full Beam Configuration Inverse Planning in Coplanar Radiotherapy Vitoantonio Bevilacqua Giuseppe Mastronardi Giuseppe Piscopo bevilacqua@poliba.it mastrona@poliba.it giuseppe.piscopo@katamail.com

More information

Chapter 9 Field Shaping: Scanning Beam

Chapter 9 Field Shaping: Scanning Beam Chapter 9 Field Shaping: Scanning Beam X. Ronald Zhu, Ph.D. Department of Radiation Physics M. D. Anderson Cancer Center Houston, TX June 14-18, 2015 AAPM - Summer School 2015, Colorado Spring Acknowledgement

More information

arxiv: v1 [physics.med-ph] 22 Dec 2011

arxiv: v1 [physics.med-ph] 22 Dec 2011 Including Robustness in Multi-criteria Optimization for Intensity Modulated Proton Therapy arxiv:2.5362v [physics.med-ph] 22 Dec 20 Wei Chen, Jan Unkelbach, Alexei Trofimov, Thomas Madden, Hanne Kooy,

More information

Photon Dose Algorithms and Physics Data Modeling in modern RTP

Photon Dose Algorithms and Physics Data Modeling in modern RTP Photon Dose Algorithms and Physics Data Modeling in modern RTP Niko Papanikolaou, PhD Professor and Director of Medical Physics University of Texas Health Science Center of San Antonio Cancer Therapy &

More information

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT CLINICAL COMMISSIONING AND ACCEPTANCE TESTING OF A 3D SURFACE MATCHING SYSTEM Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago Learning Objective Describe acceptance

More information

7/31/ D Cone-Beam CT: Developments and Applications. Disclosure. Outline. I have received research funding from NIH and Varian Medical System.

7/31/ D Cone-Beam CT: Developments and Applications. Disclosure. Outline. I have received research funding from NIH and Varian Medical System. 4D Cone-Beam CT: Developments and Applications Lei Ren, PhD, DABR Department of Radiation Oncology Duke University Medical Center Disclosure I have received research funding from NIH and Varian Medical

More information

CARS 2008 Computer Assisted Radiology and Surgery

CARS 2008 Computer Assisted Radiology and Surgery Online External Beam Radiation Planning and Training Felix Hamza-Lup a, Ivan Sopin a, Omar Zeidan b a Computer Science, Armstrong Atlantic State University, Savannah, Georgia, USA b MD Anderson Cancer

More information

Walk Through of CERR Capabilities. CERR: Introduction. Outline. Getting CERR: Control Panel. Documentation Support Community

Walk Through of CERR Capabilities. CERR: Introduction. Outline. Getting CERR: Control Panel. Documentation Support Community Walk Through of CERR Capabilities Aditya P. Apte, Ph.D. Department of Medical Physics Memorial Sloan Kettering Cancer Center New York aptea@mskcc.org AAPM 2015, July 15, 2015 CERR: Computational Environment

More information

enal++: a new and effective off-line correction protocol for rotational setup errors when using a robotic couch

enal++: a new and effective off-line correction protocol for rotational setup errors when using a robotic couch JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015 enal++: a new and effective off-line correction protocol for rotational setup errors when using a robotic couch Daan Martens, 1 Mark

More information

Applied Optimization Application to Intensity-Modulated Radiation Therapy (IMRT)

Applied Optimization Application to Intensity-Modulated Radiation Therapy (IMRT) Applied Optimization Application to Intensity-Modulated Radiation Therapy (IMRT) 2009-05-08 Caroline Olsson, M.Sc. Topics History of radiotherapy Developments that has led to IMRT The IMRT process How

More information

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004 Qalitätssicherung an Multileafkollimatoren Dr. Lutz Müller Würzburg jan 2004 IMRT Verification - present Target Volume Constraints Inverse Planning Algorithm Fluence Map Leaf Sequencer Leaf & Gantry sequence

More information

Trajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy

Trajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy Trajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy Gregory Smyth 1, Jeffrey C Bamber 1, Philip M Evans 2 and James L Bedford 1 1 Joint Department of Physics,

More information

Dynalog data tool for IMRT plan verification

Dynalog data tool for IMRT plan verification Dynalog data tool for IMRT plan verification Poster No.: R-0051 Congress: 2014 CSM Type: Scientific Exhibit Authors: V. Sashin; FOOTSCRAY/AU Keywords: Computer applications, Radiation physics, Experimental,

More information

Beam Orientation Optimization for Intensity Modulated Radiation Therapy using Adaptive l 1 Minimization

Beam Orientation Optimization for Intensity Modulated Radiation Therapy using Adaptive l 1 Minimization Beam Orientation Optimization for Intensity Modulated Radiation Therapy using Adaptive l 1 Minimization Xun Jia 1, Chunhua Men 1, Yifei Lou 2, and Steve B. Jiang 1 1 Center for Advanced Radiotherapy Technologies

More information

Dosimetric Analysis Report

Dosimetric Analysis Report RT-safe 48, Artotinis str 116 33, Athens Greece +30 2107563691 info@rt-safe.com Dosimetric Analysis Report SAMPLE, for demonstration purposes only Date of report: ----------- Date of irradiation: -----------

More information

ADAPTIVE HYBRID SURGERY ANALYSIS

ADAPTIVE HYBRID SURGERY ANALYSIS ADAPTIVE HYBRID SURGERY ANALYSIS Version 1.0 Software User Guide Revision 1.1 Copyright 2015, Brainlab AG Germany. All rights reserved. TABLE OF CONTENTS TABLE OF CONTENTS GENERAL INFORMATION...5 Contact

More information

3DVH FAQs. What is PDP questions

3DVH FAQs. What is PDP questions 3DVH FAQs What is PDP questions 1. Explain the PDP in layman terms. How does PDP work? a. Very simply, PDP uses measured diode data, and compares it to the expected treatment plan data. The differences

More information

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015 JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015 Quantification of dose differences between two versions of Acuros XB algorithm compared to Monte Carlo simulations the effect on clinical

More information

An optimization framework for conformal radiation treatment planning

An optimization framework for conformal radiation treatment planning An optimization framework for conformal radiation treatment planning Jinho Lim Michael C. Ferris Stephen J. Wright David M. Shepard Matthew A. Earl December 2002 Abstract An optimization framework for

More information

A derivative-free multistart framework for an automated noncoplanar beam angle optimization in IMRT

A derivative-free multistart framework for an automated noncoplanar beam angle optimization in IMRT A derivative-free multistart framework for an automated noncoplanar beam angle optimization in IMRT Humberto Rocha and Joana Dias FEUC and Inesc-Coimbra, University of Coimbra, Portugal 5 1 Tiago Ventura

More information

PET/CT multimodality imaging for radiotherapy planning in lung cancer The medical physicist point of view Isabelle Gardin Rouen CHB and Quant.I.

PET/CT multimodality imaging for radiotherapy planning in lung cancer The medical physicist point of view Isabelle Gardin Rouen CHB and Quant.I. PET/CT multimodality imaging for radiotherapy planning in lung cancer The medical physicist point of view Isabelle Gardin Rouen CHB and Quant.I.F (EA4108 FR CNRS 3638) Outline Specific acquisition conditions

More information

Computational modelling and analysis: IOP Medical Physics Group

Computational modelling and analysis: IOP Medical Physics Group Computational modelling and analysis: IOP Medical Physics Group Using Bespoke Matlab Software for the Collection and Processing of Dynalog Files from the Varian Millennium 120 MLC system following delivery

More information

Shared datasets for IMRT, beam angle optimization, and VMAT research

Shared datasets for IMRT, beam angle optimization, and VMAT research Craft et al. RESEARCH Shared datasets for IMRT, beam angle optimization, and VMAT research David Craft 1*, Mark Bangert 2, Troy Long 3, Dávid Papp 1 and Jan Unkelbach 1 * Correspondence: dcraft@mgh.harvard.edu

More information

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail.

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail. This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail. Author(s): Bokrantz, Rasmus; Miettinen, Kaisa Title: Projections onto

More information

Application of polynomial chaos in proton therapy

Application of polynomial chaos in proton therapy Application of polynomial chaos in proton therapy Dose distributions, treatment parameters, robustness recipes & treatment planning Master Thesis S.R. van der Voort June, 215 Supervisors: Dr. Ir. D. Lathouwers

More information