1 Spec. Sheet Tel: (705) Web: Fax: (705) Model #DPM02 Model #DWM02 FEATURES #DXX02 Programmable Display for Meters,Feet and User Defined Units The ABM Display,Model DXM02 current loop powered display indicates the percentage full or empty of the tank whose level is being monitored by a sensor with a Ma output. The display can also be calibrated in Meters,Feet or User Defined units. The display can be changed to indicate 100% at ma or ma by simply moving an internal link. The display is packaged in a compact NEMA X enclosure which can be wall mounted or probe mounted. Specification: Display 1/2 Digit LCD 1/2 (12.7mm) High Temperature 0 to 10 F(0 to 60 C) Voltage Drop: ma Accuracy Reading +/0.5% Humidity: Range: 0 95% NonCondensing 3.5 ma to 22mA Maximum current: 150 ma Display Range: Normal 100%@ ma 3% to 112% 0%@ ma Reverse 100%@ ma 12% to +113% 0%@ ma 22mA and above LOE (Loss of Echo) Enclosure Outline: 3.53" 2.367" LOOP POWERED DILAY % 1/2 High (12.7mm) 3 Digit LCD Display 0.236".056".528" Enclosure: Nema X, IP65 Refer to Catalogue Number below for ordering Information. Catalogue #DXX02 WM wall mount PM probe mount Front View Ø0.172" Typ. of Mtg. Holes 1 10A32 R2
2 User Instruction Manual Tel: (705) Web: Fax: (705) Fig.#1) Inter Connection Diagram For D To ABM 3 Wire Level Transmitter ma ma 2V DC ma! RS232/85 A/TX 2 B/RX 1 FUSE F1/8 A 250V See Note ma See Note +V ma Gnd. + ma ma Gnd. Neut. Line STATUS CALIBRATION SWITCH ABM 3 Wire Level Transmitter Fig.#2) Inter Connection Diagram For D To ABM Wire Level Transmitter ma Note Remove jumper if other device is to be connected ACV IN ma RS232/85 A/TX 2 Fig.#3) Inter Connection Diagram For D To ABM 2 Wire Level Transmitter! L1 8 L2/N B/RX 1 F1/8 A 250V 3 STATUS CALIBRATION SWITCH FUSE ABM Line Neut. Gnd. + ma ma Wire Level Transmitter ma + Loop Voltage ma + STATUS ABM Calibration ma 2 Wire Level ma Transmitter + V max. = 28 Vdc V min. = 12 Vdc 2
3 User Instruction Manual Tel: (705) Web: Fax: (705) Fig.#1) Inter Connection Diagram For D To 3 Wire Level Transmitter ma ma +V ma. GND. See Note +V ma Gnd. 3 Wire Level Transmitter Fig.#2) Inter Connection Diagram For D To Wire Level Transmitter L Neut. GND. L N GND. Place jumper here for ma ma + ma. ma. See Note + ma ma Wire Level Transmitter Note Remove jumper if other device is to be connected Fig.#3) Inter Connection Diagram For D To 2 Wire Level Transmitter ma ma +ma. ma. + Loop Voltage ma Transmitter 3
4 Programming Manual Tel: (705) Web: Fax: (705) ECIFICATIONS PHYSICAL DILAY 1/2 DIGIT LCD Display range Normal mode ma and ma Setting: jumper J1 to Reverse mode ma and ma Setting: jumper J1 to Display mode Percentage Normal: 3% to 112% Reverse: 12% to 113% Meter Normal/Reverse: 0.00 m to m (0 to cm) 0 cm corresponds to 0% and up to cm correspond to 100% in any mode Feet Normal/Reverse: 0 ft 00 in to 199 ft 11 in. (0 to 2399 in) 0 ft corresponds to 0% and up to 2399 in. correspond to 100% in any mode User defined Normal/Reverse: 0 to in direct indication and up to in indirect indication 0 corresponds to 0% and up to correspond to 100% in any mode DILAY FORMAT INDICATION INDICATION IN PERCENTAGE Negative Percentage ( if minus is ON) or Percent Indication (Normal mode if indicator is ON) Percent Indication (Reverse mode if indicator is ON) INDICATION IN METERS Meter Indication Centimeters 0 to Meters 0 to 199 Decimal Point INDICATION IN FEET Feet Indication Inches 0 to 11 : Feet 0 to 199 Separates inch from feet USER DEFINED INDICATION Indirect Indication Multiplier: 100 No colon or Minus sign is on Range Multiplier O to Direct Indication Indirect Indication Range: 000 to Obtain value: 655 x 100 = 65500
5 Programming Manual Examples Tel: (705) Web: Readout Setup Long Press Short Press Menu Options MO Unit Indicator UI 100 Readout in measurement (longer than 1.5 S.) MO Menu options: MO Menu Editing Unit Indicator: UI Meters : Feet/Inch No sign User Defined indicator on right side of display (Percentage) MO MO S 1 P percentage E meter F feet/inch : L liter S step A max calibration value Max. height of the material I min calibration value Min. height of the material o store settings (for 100% at ma.) Step value 2 A 3 (press as many times as needed) Step value and multiply o I 5 o Step value and multiply 6 Repeat steps 1 to 6 To complete calib. values o Blinks or 25 sec Measurement Display format: Meter Foot Liter Calibration value min max default min max default min max default Boundaries: Min Max Possible values 0.01m 0.01m 1in 1in 1 1 for Step (positive 0.10m 0.10m 1ft 1ft and negative) 1.00 m 1.00m 10ft 10ft m 10.00m 100ft 100ft m m
6 Programming Manual Examples Tel: (705) Fax: (705) Web: Example 1 : From Normal Percent Display Mode (100% = Ma.) program readout in meters with : Maximum Calibration equal to 6.1 m and Minimum Calibration equal to 1.1 m. Where : Long Press is : Short Press is Meters E A (6 times) Menu Editing E 6.10 Display in Meters E Minimum Calibration I Step S 1.10 Choose Step 0.1 o Maximum Calibration A o 0.1 Blinks,Storage of calib. values in memory o or 25 sec. Minimum Calibration I Measurement in meters s 6
7 Programming Manual Examples Tel: (705) Fax: (705) Web: Example 2 : From Normal Percent Display Mode (100% = Ma.) program readout in Feet and inches with : Maximum Calibration equal to 2 Ft. 10 inches and Minimum Calibration equal to 1 Ft. 11 inches Where : Long Press is : Short Press is Default Normal Percentage Display F : A (2 times) Menu Editing F 2 Feet 10 Inches : 2.10 Display in Feet : : F : I Step : S : 1.11 Select Step 0.01 which is 1 inch 0.01 : o Maximum Calibration : A : o (10 times) : 0.10 Blinks,Storage of calib. values in memory : o or 25 sec. Minimum Calibration : I Shows 2 Feet and 1 Inch : 2.01 (11 times) : 0.11 : s 7
8 Programming Manual Examples Tel: (705) Fax: (705) Web: Example 3 : Readout is programmed in Meters go back to Normal Percent Display Mode (100% = Ma.) Where : Long Press is : Short Press is 5.90 P P Normal Percentage Display Blinks P o o o 56 or 25 sec. 8
9 Probe Mounting Equipment Technical Specifications Tel. (705) Web: Fax:(705) " 0.670" % 3.125"Ø 0.75" Model # Dimension Dimension 'A' 'B' ABM300/XX05UL 9.65" 3.0" ABM300/XX052UL 10.05" 3.05" ABM300/XX070UL 9.25" 2.25" 'A' ABM300/XX080UL 9.25" 2.25" ABM300/XX081UL 9.15" 2.1" ABM300/XX018UL 9.0" 2.0" 1.0" 'B' 9 10
Series ULT Ultrasonic Level Transmitter
Bulletin L-45 Series ULT Ultrasonic Level Transmitter Specifications - Installation and Operating Instructions 3 29/32 [99.21] 4 9/32 [108.74] 2X 1/2 NPT ø3 21/64 [84.53] 8 1/16 [204.79] Series ULT Ultrasonic
More informationAir Quality Solutions
Air Quality Solutions Installation & Maintenance Manual Model: DPT-IQ Flow Meter with Backlit Display II-DPT-IQ-1218/Replaces II-DPT-IQ-818 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR
More informationLAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and
More informationHumidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315
Humidity + Temp. + Dew Point Pocket size HUMIDITY METER Model : HT-315 TABLE OF CONTENTS 1. FEATURES...1 2. SPECIFICATIONS... 2 3. FRONT PANEL DESCRIPTION...5 3-1 Display...5 3-2 Power Button...5 3-3 Hold
More informationHTZ. Description. Features. Smart HART Humidity and Temperature Transmitter
March 2018 Description The HTZ Smart HART Transmitter simultaneously measures humidity and temperature in industrial, commercial, manufacturing, and HVAC applications. Based on the humidity and temperature
More informationLPG STM 94442A User s Manual
1 LPG STM 94442A User s Manual This Manual belongs to: Company: 3 Table of Contents Features....... 4 Hardware Installation...5 Monitor Mounting Dimensions.....7 Monitor Specifications...8 Sender Specifications.....9
More informationInstallation manual CF8-W-Disp-AL
Installation manual CF8-W-Disp-AL CO 2 transmitter with two relays mounted in industrial housing prepared for Modbus communication protocol 4 7 8 8 6 3 2 5 Wall plate 5 Snap-in lid 2 PCB (Factory supplied
More informationDWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.
Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationZone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions
Product Identification BAPI s Touch Low Range Pressure Sensor with Attached Static Pressure Probe is an accurate, rugged and economical solution for measuring and reporting duct/building static pressure,
More informationMinilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values
Technical Information Minilog RDL10 Measured value collector with 2 input channels for storing analog and digital values Application Data storage for termperature, humidity, pressure, flow, level, and
More informationLAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.
Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile
More informationTOXALERT MODEL AIR 2000
TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.
More informationCONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA
CONVERTER MC406 Electromagnetic flowmeter The battery powered electronic converter DS400-1-USA Converter MC406 The MC406 is the new high -efficiency, technologically advanced battery powered electronic
More informationJANUARY 2000 TS800A TS801. MicroScanner
JANUARY 2000 TS800A TS801 MicroScanner CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week:
More informationINSTRUCTION MANUAL MODEL RTI-EC RESISTANCE TEMPERATURE INDICATOR TABLE OF CONTENTS 1. GENERAL DESCRIPTION PAGE 1
DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com INSTRUCTION MANUAL MODEL RTI-EC RESISTANCE TEMPERATURE INDICATOR TABLE OF CONTENTS
More informationHPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions
DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL
More informationZone Pressure Touch (ZPT) Sensor - Standard Range
Product Identification BAPI s Touch Pressure Sensor is an accurate, rugged and economical solution for measuring and reporting duct/ building static pressure, room-to-room differential pressure or air
More informationMCS-2015 Basic power supply for on-off and emergency 115 VAC Electrak 1 stop. 115 VAC or 230 VAC input. 230 VAC Electrak 10 Electrak 100
Whether you plan to operate from a simple pushbutton or a programmable controller, the MCS-2000 series controls can make your system easy to design and install and simple to operate. Designed to drive
More informationGF92 Installation, Operation and Troubleshooting Guide
24 Hour Factory Service Hot Line: 1 (800) 854-1993 GF92 Installation, Operation and Troubleshooting Guide Document 06EN003321 Rev. - A. To get the best results from the instrument, the sensor should be
More informationTable of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION
Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationTransmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD
Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x D 1 INTRODUCTION The RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD transmitters
More informationGF90 Installation, Operation and Troubleshooting Guide
24 Hour Factory Service Hot Line: 1 (800) 854-1993 GF90 Installation, Operation and Troubleshooting Guide Document 06EN003319 Rev. - A. To get the best results from the instrument, the sensor should be
More information40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER
40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER Model : LX-1102 Your purchase of this LIGHT METER marks a step forward for you into the field of precision measurement. Although this LIGHT METER is a complex
More informationOilCop Component Wiring Installation Manual
OilCop Component Wiring Installation Manual This info sheet contains important information. READ AND KEEP FOR REFERENCE. 2311 S. Edwards Wichita, KS 67213 TEL: 316-943-5477 FAX: 316-943-4760 TOLL FREE:
More informationTABLE OF CONTENTS 1. FEATURES SPECIFICATIONS General Specifications Electrical Specifications...3
DIGITAL LIGHT METER TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications...3 3. FRONT PANEL DESCRIPTION...4 3-1 Display... 4 3-2 Power
More informationINSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION
INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.02-11.10 TABLE
More informationaccurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationSHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions
SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions http://www.kep.com KESSLER-ELLIS PRODUCTS 10 Industrial Way East Eatontown, NJ 07724 800-631-2165 732-935-1320
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationBusiness. Republic of SEWHACNM to the world beyond. 1 2 Industrial Automation
Business 1 2 Industrial Automation Indicator - Simple Digital Weighing Indicator - Universal Weighing Indicator - Packaging Control Indicator - Multiple Mixture Control Indicator - DIN Size Digital Weighing
More informationWelcome to the Webinar
Welcome to the Webinar Climbing Up Tanks is Dangerous and a Waste of Time Here is a Level Transmitter with a Display, but.. Precision Digital Indicators and Controllers Are the Convenient and Safe Solution
More informationPGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationThe PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.
PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION
More information+GF+ SIGNET ph/orp Transmitter Instructions
GF SIGNET 8750 ph/orp Transmitter Instructions ENGLISH 8750.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
More informationEchotouch, EchoSpan & EchoSwitch Ultrasonic Liquid
Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that
More informationNEUROLOGIC RESEARCH CORPORATION MODEL 2500
NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication
More informationPrecision humidity/temperature control/sensing
HIGH ACCURACY HUMIDITY/TEMPERATURE TRANSMITTER HAHT Series Precision humidity/temperature control/sensing FEATURES: Highly stable RH sensor element Humidity range: 0-100% Accuracy available 1% & 2% High
More informationEE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationLAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationTC22/23/24/25 Capacitance level transmitter - electronic preamplifi er
TC22/23/24/25 Capacitance level transmitter - electronic preamplifi er technical documentation EN Rev. S TC22 25 - contents CONTENTS 1-WARRANTY 2-PRODUCT 3-TECHNICAL FEATURES 4-DIMENSIONS 5-MECHANICAL
More informationEchotouch, EchoSpan & EchoSwitch Ultrasonic Liquid
Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that
More informationLAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.
Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals
More informationStandard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter
Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationSimplified information where and how you want it.
ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator
More informationLAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 Arithmetic functions A+B, A-B, AxB, A/B, A/B-1 applied to rate or total for channels
More informationColor Mark Photoelectric Sensor E3S-VS
Sensing Supply voltage Output 12 to 80 ma, with 1.5 to 4 ma constant current source; 1.2 cm, 5 cm 100 ma, Color Mark Photoelectric Sensor Small Color Mark Sensor With Built-In DC Amplifier Fast, 1 ms maximum
More informationMODELS PD230 AND PD1230 Installation Instructions
PNEUMERCATOR Liquid Level Control Systems MODELS PD20 AND PD20 Installation Instructions Model PD20 x2 Channel Lightning Surge Protector Model PD20 x2 Channel Lightning Surge Protector COPYRIGHT 2007 PNEUMERCATOR
More informationMICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS
The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and
More informationReal Time Clock with Temperature Sensor and RS485/Modbus Comunications
Real Time Clock with Temperature Sensor and RS485/Modbus Comunications April 29, 2014 Power 8 20 VDC @ less than 100 MA. Battery connect jumper RS485 Bus Load Jumpers Model: RTC-TI2C Page 1 of 6 Features:
More informationQuick Start Guide MC-III TM Flow Analyzer
Quick Start Guide MC-III TM Flow Analyzer A Quick Reference on Mounting, Wiring, & Configuring the MC-III EXP or WP Flow Analyzer For complete instructions, see MC-III EXP User Manual, Part No. 9A-50165003
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow
More informationLAUREL ELECTRONICS, INC.
Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals
More informationTC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.
LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate
More informationType K/J Thermometers
Type K/J Thermometers 800005 CONTENTS INTRODUCTION....2 FRONT PANEL DESCRIPTION...3 LCD DISPLAY....4 OPERATION INSTRUCTION...5 Power Up....5 Connecting the Thermocouples....5 Selecting Temperature Scale....5
More informationLE ELECTRONICS Pvt. Ltd.
LE ELECTRONICS Pvt. Ltd. Monitoring Relays: LVM Line Voltage Monitors LCM - Line Current Monitors VMR Voltage Monitoring Relays CMR Current Monitoring Relays VCMR Voltage Current Monitoring Relays LFM
More informationLevel Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology
Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology SENSORS Product Accessories Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming Document Part Number 551103
More informationInstruction Manual. M Pump Motor Controller. For file reference, please record the following data:
Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationLevel Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Accessories for liquid level transmitters Catalog
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology Accessories for liquid level transmitters Table of contents 1. Floats... 3 1.1 Standard floats... 3 1.2 Low-liftoff float...
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff
More informationMP-2000 Dual Channel LVDT/RVDT Readout/Controller
Large backlit dual channel display Menu driven setup and calibration 100 to 240 VAC line powered MIN, MAX, TIR, A+B and A-B functions 2.5, 3.3, 5 and 10kHz selectable excitation Analog and RS232 outputs
More informationEnvirondata FA ma Converter Guide
FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA,
More informationTORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional
1000 Kgf-cm, heavy duty, professional TORQUE WRENCH Model : TQ-8803 Your purchase of this 1000 Kgf-cm Torque Wrench marks a step forward for you into the field of precision measurement. Although this METER
More informationZBXYAF Oxygen sensor control circuit board
FEATURES Control circuit board for all XYA series oxygen sensors Measuring ranges...5 or... oxygen or custom adjustable range Can be calibrated in normal air or any known O concentration Automatic or manual
More informationHigh Voltage DC Meter
High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationDIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi
V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors
More informationXT-9100 Technical Bulletin
System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX
More informationPDW30 Point-To-Point Wireless Bridge
PDW30 Point-To-Point Wireless Bridge WIRELESS WIreless System FEATURES Wire Replacement in a Rugged, Industrial Housing Inputs and Outputs on Both Field Units Simple to Order, Configure, & Install 1 Mile
More informationModel 305e OEM CO 2 concentration sensor
Model 305e OEM CO 2 concentration sensor preliminary Reference manual DIGITAL CONTROL SYSTEMS 7401 SW Capitol Hwy. Portland, OR 97219 USA 503/246-8110 503/246-6747 (fax) www.dcs-inc.net Scope...3 Introduction...3
More informationNSGV Series "90DM3" Carbon Dioxide Detector
NSGV SERIES 90DM3 CARBON DIOXIDE DETECTOR NSGV Series "90DM3" Carbon Dioxide Detector 90DM3A Specifications. Power 17-27 VAC, 24-38 VDC, 200 ma Detection Range 0-200 PPM Relay Output Rating 5A, 30 Vdc
More informationMYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL
MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR LC1 MANUAL 062114 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features Dimensions WIRING
More informationRST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND
More informationTemp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
More informationFAST EnergyCam. The Smart Clip-on Meter Reader for Home and Business
FAST EnergyCam The Smart Clip-on Meter Reader for Home and Business FAST EnergyCam The Smart Clip-on Meter Reader for Home and Business FAST EnergyCam Smart metering power in a well designed and tiny package
More informationInstallation guide for RUD-1 Communication Interface
Roger Access Control System Installation guide for RUD-1 Communication Interface Firmware version: n.a. Document version: Rev. D 1. DESCRIPTION AND SPECIFICATION RUD-1 is an optional, universal, portable,
More informationUser s Manual. Models Digital Force Gauge. Additional User Manual Translations available at
User s Manual Models 475055 Digital Force Gauge Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of Extech s Model 475055 Digital Force Gauge
More informationIndicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED
Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure
More informationHIGH-VOLTAGE DC METER
HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationLAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input Features Choice of 2-1/4", 4", 6" or 8" digit heights Choice of 4 or 6 digits with decimal points Choice of
More informationDifferential Liquid/Gas Pressure Transmitter
Installation Instruction Differential Liquid/Gas Pressure Transmitter Catalog Number(s) 1414-CPZ10FWFAA, 1414-IPZ10FWFAA Explosion Hazard WARNING Do not use in an explosive or hazardous environment, with
More informationModbus TM to Yo-Yo TM Protocol Guide
IOM Modbus TM to Yo-Yo TM Protocol Guide Modbus TM to Yo-Yo TM Protocol Guide CONTENTS I. Introduction...1 II. Instructions...1 III. Example...2 IV. Commands Command 1: Tank Full...3 Command 2: Tank Empty...3
More informationPGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.
More informationMasterload II electronic meter controller for aircraft refuelling vehicles
Masterload II electronic meter controller for aircraft refuelling vechiles The Meggitt MASTERLOAD II is a powerful and versatile microprocessor based electronic meter controller. The unit is capable of
More information+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions
GF SIGNET 8850 Conductivity/Resistivity Transmitter Instructions ENGLISH 8850.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to
More informationRHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter
RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x A 1 INTRODUCTION The RHT-WM-485-LCD and RHT-DM-485-LCD transmitters include high
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationLevel Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology
Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology SENSORS Product Accessories Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming Document Part Number 551103
More informationE101 - Strain Gauge Transducer Display Module. Contents
E101 - Strain Gauge Transducer Display Module Contents Torque Transducer Display Interface: TSE3249R Strain Gauge Transducer Display Interface [E101] Operating Guide: TSE2097V (Includes Introduction, Description
More informationMYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL
MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationBTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual
BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors Installation and Operation Manual BTU-4D/BTU-4D-I Installation and Operation Manual Rev E Table of Contents Introduction... 1 TEMP OUTDOOR Sensor... 1
More informationSP6R Level Controller Operation Manual
SP6R Level Controller Operation Manual www.sjerhombus.com SP6R LEVEL CONTROLLER INTRODUCTION SJE-Rhombus, an industry leader in water and wastewater pump controls, introduces the SP6R Level Controller.
More informationDPM-3221 Digital DC Power Meter with data logging capability.
Introduction DPM-3221 Digital DC Power Meter with data logging capability. User Manual As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-200 A with the correct shunt),
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationFamily of Water Cut Analyzers
Phase Dynamics Technology for Precision Measurements Phase Dynamics, Inc. 1251 Columbia Drive Richardson, TX 75081 USA E-Mail sales@phasedynamics.com Tel: 972-680-1550 Fax: 972-680-3262 Family of Water
More informationSimplified information where and how you want it.
ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator
More informationG60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT
LINE SEIKI G0 SERIES ELECTRONIC P COUNTER or DIGITS ( Line LED Display) POWER SUPPLY (AC0 ~ 0V) PRESCALE FUNCTION KEY PROTECT, MEMORY DECIMAL POINT POSITIONING DUST / SPLASH PROOF G0 - G0 - MODEL SELECTION
More informationMODEL: 40DN. Digital Panel Meters 40 Series
Digital Panel Meters 40 Series LOOP POWERED DIGITAL PANEL METER (4 digits, process meter) Functions & Features 4 digit (±9999) loop powered panel meter No external power source needed Scaling function