WAGO Kontakttechnik GmbH & Co. KG

Size: px
Start display at page:

Download "WAGO Kontakttechnik GmbH & Co. KG"

Transcription

1 0 WAG Kontakttechnik GmbH & Co. KG Project name: Project number: Drawing number: : Part number: CS_DE_00_ CS_DE_00 CD_AC_V LM max. AC_V_LM_max / Customer: WAG Kontakttechnik GmbH & Co.KG Hansastraße Acceptance: Manufacturer: WAG Kontakttechnik GmbH & Co. KG Hansastraße Minden : Minden Deutschland Deutschland +9 (0)/- (fon) Signature: +9 (0)/-0 (fon) +9 (0)/-9 (fax) Customer number:00000 Stamp: Department: Projectservice international Person of contact: Herr Dirk Röscher info.projektservice@wago.com Created on:..0 from Handled on: from Number of pages: WAG is a registered trademark of WAG Verwaltungsgesellschaft mbh AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Title page / cover sheet =

2 0 Table of contents Column X: An automatically created page was manually reworked description Supplementary page field Edited by X / Title page / cover sheet / Table of contents /. Table of contents / Revision control / Technical info / Technical info / Hints / Production hints =A+/ Construction =A+/9 PLC-verview =A+/9. PLC-verview =A+/9. PLC-verview =A+/9. =A+/9. =A+/9. =A+/9. =A+/0 =A+/ =A+/ =A+/ =A+/ =A+/ =A+/ =A+/ =A+/ =A+/9 =A+/0 =A+/ =A+/ =A+/ =A+/ =A+/ =A+/ PLC-verview PLC-verview PLC-verview PLC-verview Power Supply control voltage VDC DALI control voltage VDC Controller Supply Controller Interface Digital Inputs Digital Inputs Digital Inputs Digital Inputs Digital Inputs Digital Inputs Digital Inputs Digital Inputs Digital utputs Digital utputs Digital utputs Digital utputs Relay AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Table of contents =.

3 0 Table of contents Column X: An automatically created page was manually reworked description Supplementary page field Edited by X =A+/ =A+/ =A+/9 =A+/0 =A+/ =A+/ =A+/ =A+/ =A+/ =A+/ =A+/ =A+/ =A+/9 =A+/0 =A+/ =A+/ =A+/ =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+KLP/. =REP+KLP/. =REP+KLP/. =REP+KLP/ =REP+KLP/. =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+SN/ =REP+SN/. Relay Relay Relay Seriel Interface Seriel Interface Real-Time-Clock-Modul DALI-Master DALI-Master DALI-Master DALI-Master DALI-Master DALI-Master DALI-Master DALI-Master.0.0 DALI-Master DALI-Master Phase Power Measurement Module Terminal-strip overview : =A+-X0 - =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Parts list : WAG.9- - WAG Parts list : WAG.- - WAG AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Table of contents =.

4 0 Revision overview Creator Revision name Revision description Production status AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Revision control =

5 0 Technical information: Miscellaneous Applied norms Brand: WAG Switchgear and controlgear assembly IEC 9- - General rules Type: Automation Cabinet IEC 9- - Power switchgear and controlgear assemblies (PSC) Measurements w/h/d: 0 x 90 mm IEC 9- - Distribution boards intended to be operated by ordinary persons (DB) Degree of protection: Protection class: IP0 I Boxes and enclosures for electrical accessories: IEC 00- Installation type Door hinge: mounting in enclosure without Miscellaneous Cable routing: above / below Ambient air temperature: 0 C bis + C Relative humidity: - 9 % (moisture condensation and direct sun heat inadmissible) Special service conditions - Network configuration: Rated voltage (Un): Rated operatonal voltage (Ue): Rated insulation voltage (Ui): Rated impulse withstand voltage (UImp) Rated current (In) Rated current of a circuit (Inc) Rated peak withstand current (lpk) Rated diversity factor (RDF): Rated frequency (fn): TN-S/TT 0 VAC / VDC Ue (separated neutral conductors and protective conductors within the entire system) / 0 VAC / 00 VAC kv (ÜSK III) A please refer to circuit plan The switchgear and controlgear assembly is designated for electronic installations with either a prospective short-circuit current not rising above 0 ka or a protection by current limiting protective devices with a maximum switch-off current of ka. 0,9 0 Hz Year of construction 0 Electromagnetic compatibility (EMC): Environment A This product is appropriate for environment A. Unwanted electromagnetic disturbances may be caused in environment B; in this case, the user can be obliged to take the appropriate steps AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Technical info =

6 0 Technical information: Conductor colours according to EN 00- (DIN IEC0) Conductor cross-sections (H0/H0V-K) Load circuits External conductor black BK Cross-section for at least % of the rated current (circuit) Minimum requirement: Neutral conductor N blue BU Load circuits 0V/00VAC min. mm² Protective earth conductor PE green-yellow GNYE Control power Signal voltage min. 0. mm² min. mm² Control power: 0VAC (L) red RD 0VAC (N) red/-white RDWH Enclosure grounding Details are primarily shown in the diagram! min.. mm² (depending on the external conductor) VAC 0VAC brown brown/-white BN BNWH VDC 0VDC dark blue dark blue/-white DKBU DKBUWH External voltage Analog-/measurement signal orange white G WT DALI violet VT Serial interface RS/ grey GY SMI turquoise TQ Further bus applications pink PK KNX/LN J-Y(ST)Y xx0. mm green AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Technical info =

7 0 Hints for switchgear and controlgear combination (SGC): Electric connection: The switchgear and controlgear assembly can only be opened, installed, connected, serviced and started up by skilled persons (according to IEC 9- section.. respectively DIN VDE 00 part 00). Circuit diagram: All switch contacts are shown in a disconnected off-mode. Upon connecting the switchgear and controlgear assembly as well as other external field devices, it is essential to comply with the relevant VDE-regulations, the manufacturers' guidelines as well as the local or national regulations. The switchgear and controlgear assembly is designated to be used for the public low-voltage power supply network. The system voltage has to correspond with the nominal voltage of the switchgear and controlgear assembly and must be within the defined limits for voltage ranges as defined in the VDE-regulations.. In case of a three-phase A.C. current supply, a right rotating field has to be taken care of. Fusing of the switchgear and controlgear assembly is done on site in consideration of the given nominal current (page ) and the local or national regulations. In order to avoid failures, all bus and control cables have to be installed separately from other power supply cables carrying system voltage. Hints for CE-labelling: All switching devices and components built into the switchgear and controlgear assembly are CE-labelled, subject to the condition that those devices require this type of labelling. The switching devices and components meet the requirements of the EC-directives regarding low-voltage, switching devices and components as well as electromagnetic compatibility Starting up: Before starting-up of the switchgear and controlgear assembly, all terminal and screw connections must be checked for tight fighting and retightened if needed, in accordance with VDE 0.. Motor protection switches, overcurrent relays etc. have to be set to the respective nominal currents and documented Within the process of starting-up, live cables must be checked in respect of insulation faults and fracture points If the enclosure needs to be opened after the start-up, it must be disconnected from voltage beforehand. The inspection of cable lengths and cross-sections supplying consumer-, command- and monitoring devices must be performed by the installation company/start-up engineer. (DIN VDE 000 part 0 and VDE 09 part ). The cable cross-sections shown refer to minimum cross-sections without considering external cable lengths. All potentially listed cable cross-sections and cable types should be regarded as suggestions When starting up, all functions have to be checked as well as documented. We would like to indicate that after reconstructing or substantially changing the electric installations, an initial testing according to VDE will have to be made, before the user is allowed to conduct a start-up. This inital testing has to be performed by a skilled person being competent to perform such a testing. The initial testing is not part of our performance. We would be more than happy to give you the details of a specialist electric company which can perform the neccessary testing for you Duplicating and/or passing this diagram to any third party without an explicit written permission by WAG Kontakttechnik GmbH & Co. KG is not allowed and may lead to prosecution. Any noncompliance commits to compensation. All rights are reserved in case of granting a patent or applying for a utility model registration. Any amendments or extensions conducted without written permission by WAG Kontakttechnik GmbH & Co. KG will lead to expiration of all types of guarantees AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Hints =

8 AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Production hints = =A+/

9 RUN STP RESET SD K -9K -9K -9K -9K -9K -9K -9K -9K -T -T -T -9K -9K -9K -9K -9K -9K -9K9-9K0-9K L N PE INPUT UTPUT - ADJ. DC K X0-9K0 -X 0er - 0mm 0er - 90mm -X -X -X 90 0er - 0mm -9K0 -K. -K. -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K 0er - 90mm -K -K -K -K -K -K -K 0er - 0mm -X -X -9K -9K9 U SYS RST X RS/ U U U U RUN I/ MS NS U U ACT X LNK ACT X LNK 0-0/ K =+/ AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Construction 9

10 U SYS RST U RUN U I/ U MS U NS U USR 0-0/ K /. /9..0 /. -9K /. /. /9..0-9K /. /. /9.. -9K /. /9. /9.. -9K /0. /. /9..0-9K /. /. /9..0-9K /. /. /9.. -9K /0. /9.. -9K9 /. /9..0-9K0 /. /9..0-9K /. /9.. -9K /. /9.. -9K /. /9..0-9K /. /9..0-9K /. /9.. -9K /. /9.. -9K /9. /9..0-9K /0. /9..0-9K9 /. /9.. -9K0 /. /9.. -9K /. /9..0-9K AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + PLC-verview 9. 9

11 0-9K 0-0/000-0 SPS - Controller PFC00 Lighting Management V /. 0V /. V /. V /. 0V /. 0V /. FE /. FE /. X RJ /. X RJ /. X RS/ /. V 0V V V 0V 0V FE FE RJ_ RJ_ RS/ -9K 0-0 -channel digital input I.0 DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I.0 DI9 9 /. I. DI0 0 /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. -X: -X: -X: -X:0 -X: -X: -X: -X: -X:0 -X: -X: -X: -X: -X:0 -X: -X: DI DI DI9 DI0 DI DI DI DI DI DI DI DI DI9 DI0 DI DI -9K 0-0 -channel digital input I0.0 DI /. I0. DI /. I0. DI /. I0. DI /. I0. DI /. I0. DI /. I0. DI /. I0. DI /. I.0 DI9 9 /. I. DI0 0 /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. -X: -X: -X: -X: -X:0 -X: -X: -X: -X: -X:0 -X: -X: -X: -X: -X:0 -X: Master on/off construction site operation (pushbuttoninput) DI DI DI DI DI DI DI DI9 DI0 DI DI DI DI DI DI -9K 0-0 -channel digital input I.0 DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I.0 DI9 9 /9. I. DI0 0 /9. I. DI /9. I. DI /9. I. DI /9. I. DI /9. I. DI /9. I. DI /9. -X: -X: -X:0 -X: -X: -X: -X: -X:0 -X: -X: -X: -X: -X:90 -X:9 -X:9 -X:9 DI DI DI DI DI DI DI9 DI0 DI DI DI DI DI DI DI DI AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + PLC-verview 9. 9.

12 0-9K 0-0 -channel digital input I.0 DI /0. I. DI /0. I. DI /0. I. DI /0. I. DI /0. I. DI /0. I. DI /0. I. DI /0. I.0 DI9 9 /. I. DI0 0 /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. -X:9 -X:00 -X:0 -X:0 -X:0 -X:0 -X:0 -X: -X: -X: -X: -X:0 -X: -X: -X: -X: DI9 DI0 DI DI DI DI DI DI DI DI DI9 DI0 DI DI DI DI -9K 0-0 -channel digital output Q.0 D /. Q. D /. Q. D /. Q. D /. Q. D /. Q. D /. Q. D /. Q. D /. Q.0 D9 9 /. Q. D0 0 /. Q. D /. Q. D /. Q. D /. Q. D /. Q. D /. Q. D /. -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A D D D9 D0 D D D D D D D D D9 D0 D D -9K 0-0 -channel digital output Q0.0 D /. Q0. D /. Q0. D /. Q0. D /. Q0. D /. Q0. D /. Q0. D /. Q0. D /. Q.0 D9 9 /. Q. D0 0 /. Q. D /. Q. D /. Q. D /. Q. D /. Q. D /. Q. D /. -K.:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A DALI powersupply on/off D D D D D D D D9 D0 D D D D D D -9K 0- RS-/ Serial Interface RTS /0. CTS /0. M /0. SH /0. TxD /0. RxD /0. M /0. SH /0. Encean interface Encean interface Encean interface Encean interface AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + PLC-verview 9. 9.

13 0-9K9 - KNX/EIB/TP Interface PRG /. +KNX -KNX PRG' +KNX -KNX -9K - DALI Multi-Master /. /. /. /. /. /. /. /. DALI-Master DALI-Master supply + supply + -9K0 0-0 Real-time clock Module V_Ant +out /. V out /. M /. Clock /. V_ant -out /. V-Ant +in /. V_Ant -in /. Schirm /. GPS-DCF-Converter UTC± -9K - DALI Multi-Master /. /. /. /. /. /. /. /. DALI-Master DALI-Master supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + PLC-verview 9. 9.

14 0-9K - DALI Multi-Master /. /. /. /. /. /. /. /. DALI-Master DALI-Master supply + supply + -9K - DALI Multi-Master /. /. /. /. /. /. /. /. DALI-Master DALI-Master supply + -9K - DALI Multi-Master /. /. /. /. /. /. /. /. DALI-Master DALI-Master supply + supply + -9K - DALI Multi-Master /. /. /. /. /. /. /. /. DALI-Master DALI-Master supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + PLC-verview 9. 9.

15 0-9K - DALI Multi-Master /9. /9. /9. /9. /9. /9. /9. /9. DALI-Master DALI-Master supply + supply + -9K9 - DALI Multi-Master /. /. /. /. /. /. /. /. DALI-Master 9 DALI-Master 9 supply + supply + -9K - DALI Multi-Master /0. /0. /0. /0. /0. /0. /0. /0. DALI-Master DALI-Master supply + supply + -9K0 - DALI Multi-Master /. /. /. /. /. /. /. /. DALI-Master 0 DALI-Master 0 supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + PLC-verview 9. 9.

16 0-9K 0-9 -Phase Power Measurement PIW L /. PIW I+ ' /. I- ' /. PIW0 L /. PIW I+ ' /. I- ' /. PIW L /. PIW I+ ' /. I- ' /. -X:L -X:S -X:L -X:S -X:L -X:S PIW N /. PIW0 IN+ ' /. IN- ' /. -X:N -X:S AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + PLC-verview 0 9.

17 0 L /.0 N /.0 PE_a /.0 PE_c /.0 PE -X0 L L N N PE PE Supply 0 V AC, 0 Hz AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Power Supply 0

18 0 0.9 / L 0.9 / N -T L N PE -T L N -T L N - EPSITRN CMPACT Power,A!!! Translation missing!!! -00 EPSITRN CMPACT Power DALI!!! Translation missing!!! -00 EPSITRN CMPACT Power DALI!!! Translation missing!!! V V V DC+ DC+ DC+ DC+ DC+ DC+ DC- DC- DC- DC- DC- DC- -K. /. -K. /. DALI+ /. DALI- /. DALI+ /. DALI- /. VDC /.0 0VDC / / PE_a control voltage V DC DALI control voltage () V DC DALI control voltage () V DC AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + control voltage VDC DALI control voltage VDC

19 0.9 / -VDC -VDC /.0-9K /9. 0-0/000-0 SPS - Controller PFC00 Lighting Management Part of V 0V V V 0V 0V FE FE.9 / 0VDC 0VDC / / PE_c V 0V V V 0V 0V FE FE AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Controller Supply

20 0-9K /9. 0-0/000-0 SPS - Controller PFC00 Lighting Management Part of RJ X RJ X RS/ X RJ_ RJ_ RS/ AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Controller Interface

21 0-9K / channel digital input Part of DI I0.0 DI I0. DI I0. DI I0. DI I0. DI I0. DI I0. DI I0..9 / -VDC -VDC /.0 -X Master on/off construction site operation (pushbuttoninput) DI DI DI DI DI DI DI AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital Inputs

22 0-9K / channel digital input Part of DI9 I.0 DI0 I. DI I. DI I. DI I. DI I. DI I. DI I / -VDC -VDC /.0 -X DI9 DI0 DI DI DI DI DI DI AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital Inputs

23 0-9K / channel digital input Part of DI I.0 DI I. DI I. DI I. DI I. DI I. DI I. DI I..9 / -VDC -VDC /.0 -X DI DI DI9 DI0 DI DI DI DI AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital Inputs

24 0-9K / channel digital input Part of DI9 I.0 DI0 I. DI I. DI I. DI I. DI I. DI I. DI I / -VDC -VDC /.0 -X DI DI DI DI DI9 DI0 DI DI AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital Inputs

25 0-9K / channel digital input Part of DI I.0 DI I. DI I. DI I. DI I. DI I. DI I. DI I..9 / -VDC -VDC / 9.0 -X DI DI DI DI DI DI DI9 DI AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital Inputs 9

26 0-9K / channel digital input Part of DI9 I.0 DI0 I. DI I. DI I. DI I. DI I. DI I. DI I / -VDC -VDC / 0.0 -X DI DI DI DI DI DI DI DI AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital Inputs 0 9

27 0-9K / channel digital input Part of DI I.0 DI I. DI I. DI I. DI I. DI I. DI I. DI I. 9.9 / -VDC -VDC /.0 -X DI9 DI0 DI DI DI DI DI DI AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital Inputs 0

28 0-9K / channel digital input Part of DI9 I.0 DI0 I. DI I. DI I. DI I. DI I. DI I. DI I / -VDC -VDC / 0.0 -X DI DI DI9 DI0 DI DI DI DI AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital Inputs

29 0-9K / channel digital output Part of D Q0.0 D Q0. D Q0. D Q0. D Q0. D Q0. D Q0. D Q0. -K. DC V A A -K. DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A.9 / 0VDC 0VDC /.0 WAG.-0 /. WAG.-0 /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. DALI () powersupply on/off DALI () powersupply on/off D D D D D D D AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital utputs

30 0-9K / channel digital output Part of D9 Q.0 D0 Q. D Q. D Q. D Q. D Q. D Q. D Q K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A.9 / 0VDC 0VDC /.0 WAG.- /.0 WAG.- /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. D9 D0 D D D D D D AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital utputs

31 0-9K / channel digital output Part of D Q.0 D Q. D Q. D Q. D Q. D Q. D Q. D Q. -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A.9 / 0VDC 0VDC /.0 WAG.- /.0 WAG.- /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. WAG.- /. D D D9 D0 D D D D AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital utputs

32 0-9K / channel digital output Part of D9 Q.0 D0 Q. D Q. D Q. D Q. D Q. D Q. D Q K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A.9 / 0VDC 0VDC / 0.0 WAG.- /9.0 WAG.- /9. WAG.- /9. WAG.- /9. WAG.- /9. WAG.- /9. WAG.- /9. WAG.- /9. D D D D D9 D0 D D AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Digital utputs

33 0 -K -K -K -K -K -K -K /. /. /. /. /. /. /. -X D D D D D D D AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Relay

34 0 -K -K -K -K -K -K -K -K /. /. /. /. /. /. /. /. -X D9 D0 D D D D D D AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Relay

35 0 -K -K -K -K -K -K -K -K /. /. /. /. /. /. /. /. -X D D D9 D0 D D D D AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Relay 9

36 0 -K -K -K -K -K -K -K -K /. /. /. /. /. /. /. /. -X D D D D D9 D0 D D AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Relay 0 9

37 0-9K /9. 0- RS-/ Serial Interface RTS CTS M SH TxD RxD M SH -0R x x 0Ω.9 / VDC.9 / 0VDC PE -X -0B V GND B A thermokon STC-RS EVC Encean interface AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Seriel Interface 0

38 0-9K9 /9. - KNX/EIB/TP Interface PRG PRG' +KNX +KNX -KNX -KNX AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Seriel Interface

39 0-9K0 / Real-time clock Module V_Ant +out V out M Clock V_ant -out V-Ant +in V_Ant -in Schirm -X B + V - out elsner GPS-DCF- Konverter UTC± GPS-DCF-Converter UTC± AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Real-Time-Clock-Modul

40 0-9K /9. - DALI Multi-Master.9 / DALI+ DALI+ /..9 / DALI- DALI- /. -X DALI-Master DALI-Master supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master

41 0-9K /9. - DALI Multi-Master.9 / DALI+ DALI+ /..9 / DALI- DALI- /. -X DALI-Master DALI-Master supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master

42 0-9K /9. - DALI Multi-Master.9 / DALI+ DALI+ /..9 / DALI- DALI- /. -X DALI-Master DALI-Master supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master

43 0-9K /9. - DALI Multi-Master.9 / DALI+ DALI+ /..9 / DALI- DALI- /. -X DALI-Master DALI-Master supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master

44 0-9K /9. - DALI Multi-Master.9 / DALI+.9 / DALI- -X DALI-Master DALI-Master supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master

45 0-9K /9. - DALI Multi-Master.9 / DALI+ DALI+ / 9..9 / DALI- DALI- / 9. -X DALI-Master DALI-Master supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master 9

46 0-9K /9. - DALI Multi-Master.9 / DALI+ DALI+ / 0..9 / DALI- DALI- / 0. -X DALI-Master DALI-Master supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master 0 9

47 0-9K /9. - DALI Multi-Master 9.9 / DALI+ DALI+ /. 9.9 / DALI- DALI- /. -X DALI-Master DALI-Master supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master 0

48 0-9K9 /9. - DALI Multi-Master 0.9 / DALI+ DALI+ /. 0.9 / DALI- DALI- /. -X DALI-Master 9 DALI-Master 9 supply + supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master 9

49 0-9K0 /9. - DALI Multi-Master.9 / DALI+.9 / DALI- -X DALI-Master 0 DALI-Master 0 supply AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + DALI-Master 0

50 0-9K / Phase Power Measurement I+ PIW I+ PIW I+ PIW0 IN+ PIW I- I- I- IN- L PIW0 L PIW L PIW N PIW ' ' ' ' ' ' ' ' PE L L -X S S L S L S L S L S N S N S L L L N PE 00- Power supply 00 V, 0 Hz 0, A AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + -Phase Power Measurement Module =REP+KLP/

51 0 Terminal-strip overview Terminal strip Terminal strip definition text Terminals first last Total PE Total N Total number Graphic page of terminal diagrams =A+-X0 =A+-X =A+-X =A+-X =A+-X =A+-X =A+-X Supply 0 V AC Digital Inputs 0 0 Digital utputs 0 0 DALI-Master Encean interface 0 -Phase Power Measurement Module S PE GPS-DCF 0 0 =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+KLP/ =A+/ AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal-strip overview : =A+-X0 - =A+-X = REP KLP

52 0 Terminal diagram Cable name Terminal diagram =A+-X0 Supply 0 V AC Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column Supply 0 V AC, 0 Hz T L /0.0 = 00-0 /0. = T N /0. = 00-0 /0. = T;-9K PE; /0. = 00-0 / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X0 = REP KLP

53 0 Terminal diagram Cable name Terminal diagram =A+-X Digital Inputs Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column Master on/off construction site operation (pushbuttoninput) K /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI /. = 0-9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI9 00- /. = -9K 9 /. DI /. = 0-9K 0 /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI /. = 0-9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI9 00- /. = -9K /. DI / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X = REP KLP.

54 0 Terminal diagram Cable name Terminal diagram =A+-X Digital Inputs Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column DI0 0-9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI /. = 0-9K 9 /. DI 00- /. = -9K 0 /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI9 00- /. = -9K /. DI /. = 0-9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI /. = 0-9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI9 00- /. = -9K / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X = REP KLP..

55 0 Terminal diagram Cable name Terminal diagram =A+-X Digital Inputs Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column DI /. = 0-9K /. DI 00- /9. = -9K 9 /9. DI 00- /9. = -9K 0 /9. DI 00- /9. = -9K /9. DI 00- /9. = -9K /9. DI /9. = 90-9K /9. DI /9. = 9-9K /9. DI /9. = 9-9K /9. DI 00- /9. = 9-9K /9. DI /0. = 9-9K /0. DI /0. = 00-9K /0. DI /0. = 0-9K /0. DI /0. = 0-9K /0. DI /0. = 0-9K /0. DI /0. = 0-9K /0. DI /0. = 0-9K /0. DI 00- /0. = -9K /0. DI 00- /. = -9K 9 /. DI 00- /. = -9K 0 /.. DI9 00- / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X = REP KLP..

56 0 Terminal diagram Cable name Terminal diagram =A+-X Digital Inputs Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column DI9-9K /. DI /. = 0-9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- -X /. = -9K / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X = REP KLP.

57 0 Terminal diagram Cable name Terminal diagram =A+-X Digital utputs Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column D 00- -K /. = -K /. D 00- -K /. = -K /. D 00- -K /. = -K /. D 00- -K /. = -K /. D K /. = 0 -K /. D 00- -K /. = -K /. D 00- -K /. = -K /. D K /. = -K /. D K /. = -K /. D K /. = 0 -K /. D 00- -K /. = -K /. D 00- -K /. = -K /. D 00- -K /. = -K /. D 00- -K /. = -K /. D K /. = 0 -K /. D 00- -K /. = -K /. D 00- -K /. = -K /. D K /. = -K /. D K /. = -K /.. D K / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X = REP KLP.

58 0 Terminal diagram Cable name Terminal diagram =A+-X Digital utputs Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column D 0 -K /. D 00- -K /. = -K /. D 00- -K /. = -K /. D 00- -K /. = -K /. D 00- -K /9. = -K /9. D K /9. = 0 -K /9. D 00- -K /9. = -K /9. D 00- -K /9. = -K /9. D K /9. = -K /9. D K /9. = -K /9. D K /9. = 0 -K /9. D 00- -K /9. = -K / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X = REP KLP.

59 0 Terminal diagram Cable name Terminal diagram =A+-X DALI-Master Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column DALI-Master K /. = - -9K /. DALI-Master K /. = - -9K /. DALI-Master K /. = - -9K /. DALI-Master K /. = - -9K /. DALI-Master K /. = - -9K /. DALI-Master K /. = - -9K /. DALI-Master K /9. = - -9K /9. DALI-Master K /0. = - -9K /0. DALI-Master K9 /. = 9- -9K9 /. DALI-Master K0 /. = 0- -9K0 / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X = REP KLP

60 0 Terminal diagram Cable name Terminal diagram =A+-X Encean interface Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column Encean interface -0B V 00- -X /0. = -0B GND -K A /0. = -0B B K /0. = -0B A -9K /0. = / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X = REP KLP

61 0 Terminal diagram Cable name Terminal diagram =A+-X -Phase Power Measurement Module Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column Power supply 00 V, 0 Hz 0, A L K /. L Power supply 00 V, 0 Hz 0, A L -9K /. L Power supply 00 V, 0 Hz 0, A L -9K /. N Power supply 00 V, 0 Hz 0, A N -9K /. Power supply 00 V, 0 Hz 0, A PE PE /. S -9K ' /. S -9K ' /. S -9K ' /. S -9K ' /. S S S S S -9K ' /. S -9K ' /. S -9K ' /. S -9K ' /. S S S S AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X = REP KLP

62 0 Terminal diagram Cable name Terminal diagram =A+-X GPS-DCF Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column GPS-DCF-Converter UTC± -B K0 /. = -B K0 /. = -B K0 / AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Terminal diagram =A+-X +SN/ = REP KLP

63 0 Parts list Device tag Quantity Designation Manufacturer Type number ERP number Part number (eplan) -0 Screwless end stop mm WAG WAG Screwless end stop mm WAG WAG Screwless end stop mm WAG WAG Screwless end stop mm WAG WAG Screwless end stop mm WAG WAG Screwless end stop mm WAG WAG Screwless end stop mm WAG WAG Screwless end stop mm WAG WAG Screwless end stop mm WAG WAG Screwless end stop mm WAG WAG.9- - Screwless end stop mm WAG WAG.9- - Screwless end stop mm WAG WAG.9- - Screwless end stop mm WAG WAG.9- - Screwless end stop mm WAG WAG.9- - Screwless end stop mm WAG WAG.9- - Screwless end stop mm WAG WAG.9- - Screwless end stop mm WAG WAG.9- -9K0 End module WAG WAG K SPS - Controller PFC00 Lighting Management WAG 0-0/ / WAG.0-0/ K Memory Card SD GB WAG -9/ / WAG.-9/ K -channel digital input WAG WAG K -channel digital input WAG WAG K -channel digital input WAG WAG K -channel digital input WAG WAG K -channel digital output WAG WAG K -channel digital output WAG WAG K RS-/ Serial Interface WAG WAG.0- -9K9 KNX/EIB/TP Interface WAG WAG.- -9K0 Real-time clock Module WAG WAG K DALI Multi-Master WAG WAG.- -9K DALI Multi-Master WAG WAG.- -9K DALI Multi-Master WAG WAG.- -9K DALI Multi-Master WAG WAG.- -9K DALI Multi-Master WAG WAG.- -9K DALI Multi-Master WAG WAG.- -9K DALI Multi-Master WAG WAG.- -9K DALI Multi-Master WAG WAG.- -9K9 DALI Multi-Master WAG WAG.- -9K0 DALI Multi-Master WAG WAG.- -9K -Phase Power Measurement WAG WAG.0-9 -K. Relay socket with relay and status indicator WAG WAG.-0 -K. Relay socket with relay and status indicator WAG WAG.-0 -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- -K Relay socket with relay ALZ WAG WAG.- +KLP/ AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Parts list : WAG.9- - WAG.- = REP SN.

64 0 Parts list Device tag Quantity Designation Manufacturer Type number ERP number Part number (eplan) -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -K -0R -T -T -T -X0 -X0 -X0 -X0 -X -X -X -X -X -X -X -X -X -X 0 Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Relay socket with relay ALZ Widerstand 0Ω EPSITRN CMPACT Power,A EPSITRN CMPACT Power DALI EPSITRN CMPACT Power DALI -conductor through terminal block grey -conductor through terminal block blue -conductor ground terminal block green-yellow End and intermediate plate orange End and intermediate plate Multilevel installation terminal block Multilevel installation terminal block End and intermediate plate Multilevel installation terminal block End and intermediate plate Multilevel installation terminal block End and intermediate plate Compact terminal block for current transformer circuit -conductor through terminal block WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG - 0- WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG WAG X End and intermediate plate WAG WAG.00-9 WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.- WAG.00- WAG.- WAG.-00 WAG.-00 WAG.00-0 WAG.00-0 WAG.00-0 WAG.00-9 WAG.00-9 WAG.00- WAG.00- WAG.00-9 WAG.00- WAG.00-9 WAG.00- WAG.00-9 WAG.00- WAG AC_V_LM_max Project no.:cs_de_00_ Draw. no.: CS_DE_00 CD_AC_V LM max. + Parts list : WAG.- - WAG.00-9 = REP SN.

WAGO Kontakttechnik GmbH & Co. KG

WAGO Kontakttechnik GmbH & Co. KG 0 WAG Kontakttechnik GmbH & Co. KG Project name: Project number: Drawing number: : Part number: CS_DE_00888_ CS_DE_00888 CD_AC_V LM min. AC_V_LM_min 8008-000/000-000 Customer: WAG Kontakttechnik GmbH &

More information

ISOMETER isopv with coupling device AGH-PV

ISOMETER isopv with coupling device AGH-PV Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for photovoltaic plants up to AC 793 V/DC 1100 V Vorläufiges Datenblatt IsoPV_D00024_02_D_XXEN/07.2018 ISOMETER with coupling

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet

More information

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

ISOMETER isoev425 with coupling device AGH420

ISOMETER isoev425 with coupling device AGH420 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A. A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K .2 X X testregistrierung TROXNETCOM AS-i Communication interface between a component and the controller The module is used to connect the control system with the components Integral AS-Interface slave

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

UTME 6. Extract from the online catalog. Order No.:

UTME 6. Extract from the online catalog. Order No.: Extract from the online catalog UTME 6 Order No.: 3047400 Test disconnect terminal block, Connection method: Screw connection, Cross section: 0.2 mm² - 10 mm², AWG: 24-8, Width: 8.2 mm, Color: gray, Mounting

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

ASI QUINT /2.4 EFD

ASI QUINT /2.4 EFD Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678

More information

IBS IL 24 BK RB-T-2MBD

IBS IL 24 BK RB-T-2MBD IBS IL 24 BK RB-T-2MBD INTERBUS Inline Terminal for Connecting a Remote Bus Branch Data Sheet 6766A 01/2003 $! $ * This data sheet is only valid in association with the "Configuring and Installing the

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

VAV compact controller GDB181.1E/3 GLB181.1E/3

VAV compact controller GDB181.1E/3 GLB181.1E/3 s 3 544 OpenAir VAV compact controller DB181.1E/3 LB181.1E/3 Series E Compact controllers for plants with variable or constant airflow Integrated high-accuracy differential pressure sensor, actuator, and

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

VAV modular controller

VAV modular controller s 3 545 OpenAir VAV modular controller Series E ASV181.1E/3 Modular controller for plants with variable or constant air volume flow Integrated high-accuracy differential pressure sensor and configurable

More information

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13 s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil

More information

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02 s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled

More information

preliminary ISOMETER isoev425 with coupling device AGH420 Preliminary datasheet

preliminary ISOMETER isoev425 with coupling device AGH420 Preliminary datasheet with coupling device GH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary edition Preliminary datasheet TD106038en /.2012 with coupling device

More information

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0

More information

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Manual -ENGLISH- Page 1 KWG-ISO Page 1 KWG-ISO Operating manual English- Status May 2013 Page 2 Manufacturer address KW-Generator GmbH & Co.KG Bänglesäcker 24 73527 Schwäbisch-Gmünd / Lindach Phone: +49 (0) 7171 104 17 0 Fax: +49 (0)

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

Decentralised operating and monitoring systems

Decentralised operating and monitoring systems MB-BAC-WA 1/4.3 X X MB-BAC-WA 1/4 testregistrierung Decentralised operating and monitoring systems Type MB-BAC-WA 1/4 Communication interface for exchanging variables via BACnet or Modbus Functional modules

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

Datasheet - SRB 402EM-24V

Datasheet - SRB 402EM-24V Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

Datasheet - SLB 200-C04-1R

Datasheet - SLB 200-C04-1R 14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety

More information

Product and functional description

Product and functional description Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AR- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 8 8- Fax +49 8 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)

More information

TM221CE40T controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221CE40T controller M221 40 IO transistor PNP Ethernet Complementary Main Discrete I/O number 40 Number of I/O expansion module Supply voltage limits Inrush current

More information

Rhino PSM Power Supplies. Operating Instructions

Rhino PSM Power Supplies. Operating Instructions Rhino PSM Power Supplies Operating Instructions RHINO Power Supplies PSM Series Description The PSM power supplies are built-in units. The mounting position for PSM power supplies must fulfill the requirements

More information

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets. 40 Series - Miniature PCB/Plug-in relays 8-10 - 12-16 40 1 & 2 Pole relay range 40.31-1 Pole 10 (3.5 mm pin pitch) 40.51-1 Pole 10 (5 mm pin pitch) 40.52-2 Pole 8 (5 mm pin pitch) PCB mount - direct or

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data.

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data. 20 70-00 PLC PFC00 Controller PFC00 CS 2ETH ECO Address Supply Configuration and programming IP-Adresse ACT X2 LNK ACT X LNK 0V X3 24V 2 3 4 6 7 0: SW/DHCP 2: DHCP RESET STOP RUN SYS RUN I/O MS NS USR

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02 s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled

More information

QUINT-PS/ 1AC/24DC/20/CO

QUINT-PS/ 1AC/24DC/20/CO Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

34 SERIES. Slim electromechanical PCB relays 6 A Ultra-slim 1 Pole - 6 A relay

34 SERIES. Slim electromechanical PCB relays 6 A Ultra-slim 1 Pole - 6 A relay 34 Slim electromechanical PCB relays 6 34 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in terminal sockets 34.51 34.51-5010

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

M-Bus Central Unit. Use

M-Bus Central Unit. Use 6 M-Bus Central Unit OZW The M-bus central unit is used for the remote readout, remote operation and supervision of an M-bus plant with a maximum of consumption meters and controllers featuring an M-bus

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

Datasheet - SRB 301LC/B-24V

Datasheet - SRB 301LC/B-24V 27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit

More information

Interface Relay CRINT-1x

Interface Relay CRINT-1x Interface Relay CRINT-1x 1 Features Space saving interface relay to combine with PLCs Coil voltage UC12, 24, 48, 60, 110-125, 220-240V Integrated protection circuit Relay is replaceable separately Available

More information

DEK-REL- 5/I/1. Extract from the online catalog. Order No.:

DEK-REL- 5/I/1. Extract from the online catalog. Order No.: Extract from the online catalog DEK-REL- 5/I/1 Order No.: 2941183 The illustration shows the version DEK-REL- 24/I/1 Relay terminal block, with soldered-in miniature relays, contact (AgNi +Au): small to

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Access Terminal IF-800

Access Terminal IF-800 95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller

More information

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0 RECTIFIER PSR380 (48V VERSION) USER MANUAL Page 2 (20) Notes to this manual ATTENTION! Read this manual very carefully before installing and commissioning the specified module. This manual is a part of

More information

MCX08M2 Programmable controller

MCX08M2 Programmable controller Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection

More information

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO Characteristics compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO Main Range of product Product or component type Complementary Enclosure material Colour Input/Output number

More information

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/40 Order No.: 2866242 Uninterruptible power supply 24 V/40 A. In the download area, there is a clearly arranged selection table available with load currents

More information

PointMaster 100. Multipoint Recorder 10/ EN

PointMaster 100. Multipoint Recorder 10/ EN PointMaster 1 Multipoint Recorder 1/41-1.1 EN 6 Measuring channels Last dot visible from the front Measuring channels electrically isolated and ungrounded Connection of process signals / 4...2 ma,...1

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

Datasheet - RSS 36-D-R-ST

Datasheet - RSS 36-D-R-ST 14.03.2018-19:30:37h Datasheet - RSS 36-D-R-ST Safety sensors / RSS 36 Thermoplastic enclosure RFID-technology for needs-based protection against tampering Misaligned actuation possible 27 mm x 108.2 mm

More information

QUINT-PS/24DC/48DC/ 5

QUINT-PS/24DC/48DC/ 5 Extract from the online catalog QUINT-PS/24DC/48DC/ 5 Order No.: 2320128 QUINT DC/DC converter, primary-switched, input: 24 V DC, output: 48 V DC/5 A Commercial data GTIN (EAN) sales group Pack Catalog

More information

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B

More information

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description IBS ST 24 BK-T Data Sheet INTERBUS-S Bus Terminal Module Data Sheet Revision A 08/994 Product Description The IBS ST 24 BK-T bus terminal module is the head station for an INTERBUS ST compact station in

More information

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples... 8 Appendix 8.1 Wiring examples...3 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126006- / H / 2017-11-17 / AE-Nr. 8410 Content 1 About

More information

Screw terminal panels, Relay output boards, connection cables

Screw terminal panels, Relay output boards, connection cables Screw terminal panels, Relay output boards, connection cables How important are cables and terminal panels? When the PC runs important controlling and regulating tasks in a processing system, then data

More information

Surge Protection for Surveillance Systems

Surge Protection for Surveillance Systems Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:

More information

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product

More information

Module 18plus. Description. 18plus

Module 18plus. Description. 18plus Module 8plus Description Wiring of load and signal lines in a space-saving manner will become ever more important for designers of electrical plants and systems, because all control cabinets and control

More information

Earth-fault Relay SPAJ 110 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral

More information

TM221CE24R controller M IO relay Ethernet

TM221CE24R controller M IO relay Ethernet Product data sheet Characteristics TM221CE24R controller M221 24 IO relay Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Inrush

More information

TM221M16R controller M IO relay

TM221M16R controller M IO relay Product data sheet Characteristics TM221M16R controller M221 16 IO relay Complementary Main Discrete I/O number 16 Number of I/O expansion module Supply voltage limits Inrush current Power consumption

More information

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green 22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR

More information

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14 Leutron Lightningand Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices Seite 0 von14 Novelties 2003 Combi Surge Protectors Leutron GmbH, 70771 Leinfelden-Echterdingen, Deutschland

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

MCX06C Programmable controller

MCX06C Programmable controller Data sheet MCX06C Programmable controller MCX06C is an electronic controller that holds all the typical functionalities of MCX controllers in the 32x74 mm standard size: programmability connection to the

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

Power Supply HARTING pcon

Power Supply HARTING pcon HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Description. Installation. Power supply

Description. Installation. Power supply Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of

More information