EC centrifugal module - RadiPac

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "EC centrifugal module - RadiPac"

Transcription

1 KG9-AR- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone Fax Limited partnership Headquarters Mulfingen County court Stuttgart HRA 5944 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 594 Nominal data Type Motor KG9-AR- MG-QA Phase ~ Nominal voltage VAC Nominal voltage range VAC Frequency Hz /6 Type of data definition State ml prelim. Speed min - 86 Power input W Current draw A.5 Min. ambient temperature C -4 Max. ambient temperature C +4 ml = Max. load me = Max. efficiency fa = Running at free air cs = Customer specs cu = Customer unit Subject to alterations Data according to ErP directive Installation category A Efficiency category Static Variable speed drive Yes Specific ratio *. * Specific ratio = + p fs / Pa Actual Request Request 5 Overall efficiency η es Efficiency grade N Power input P ed kw 7.5 Air flow q v m³/h 785 Pressure increase p fs Pa 69 Speed n min - 86 Data definition with optimum efficiency. Item no Revision 6 Release --7 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 () 8 8- Fax +49 ()

2 KG9-AR- Technical features Mass Size Surface of rotor Material of electronics housing Material of impeller kg 9 mm Coated in black Die-cast aluminium Aluminium sheet Material of inlet nozzle Sheet steel, galvanised and plastic-coated in light grey (RAL 75) Material of support structure Sheet steel, galvanised and plastic-coated in light grey (RAL 75) Number of blades 7 Direction of rotation Type of protection IP 54 Insulation class Clockwise, seen on rotor "F" Humidity class F4- Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Technical features Touch current acc. IEC 699 (measuring network Fig. 4, TN system) Electrical leads Motor protection Protection class Product conforming to standard Approval +8 C -4 C Shaft horizontal (only base mounting) or rotor on bottom; rotor on top on request Rotor-side S Ball bearing - Output VDC, max. ma - Output VDC, max. ma - Output for slave - V - Operation and alarm display - Input for sensor - V or 4- ma - External 4 V input (programming) - External release input - Alarm relay - Integrated PID controller - Motor current limit - PFC, passive - RS485 MODBUS RTU - Soft start - Control input - VDC / PWM - Control interface with SELV potential safely disconnected from the mains - Over-temperature protected electronics / motor - Line undervoltage / phase failure detection <=.5 ma Via terminal box Reverse polarity and locked-rotor protection I (if protective earth is connected by customer) EN 68-5-; CE GOST Item no Revision 6 Release --7 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 () 8 8- Fax +49 ()

3 KG9-AR- Product drawing Inlet nozzle with bleeder connection for pressure relief (k-factor: 9) Screw-on position for vibration-absorbing elements Cable diameter: min. 4 mm, max. mm, tightening torque: 4±.6 Nm 4 Cable diameter: min. 9 mm, max. 6 mm, tightening torque: 6±.9 Nm 5 Tightening torque.5±.5 Nm Item no Revision 6 Release --7 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 () 8 8- Fax +49 ()

4 KG9-AR- Connection screen No. Pin Signal Function / assignment KL L Mains supply connection, supply voltage ~8-48 VAC; /6 Hz KL L Mains supply connection, supply voltage ~8-48 VAC; /6 Hz KL L Mains supply connection, supply voltage ~8-48 VAC; /6 Hz PE PE Earth connection, PE connection KL NO Status relay, floating status contact; normally open; close with error KL COM Status relay; floating status contact; changeover contact; common connection; contact rating VAC / A (AC) KL NC Status relay, floating status contact; break with error KL RSA Bus connection RS485; RSA; MODBUS RTU KL RSB Bus connection RS485; RSB; MODBUS RTU KL / GND Signal ground for control interface KL KL 4 Ain U Analogue input (set value); - V; Ri= kω; parametrisable curves; only usable as alternative to input Ain I KL 5 + V Fixed voltage output VDC; + V +/-%; max. ma; short circuit proof; power supply for ext. devices (e.g. potentiometer) KL 6 Ain I Analogue input (set value); 4- ma; Ri= Ω; parametrisable curves; only usable as alternative to input Ain U KL 7 Din Digital input : enabling of electronics; enabling: open pin or applied voltage 5 to VDC; disabling: bridge to GND or applied voltage < VDC; reset function: triggers software reset after a level change to < V KL 8 Din Digital input : parameter set switch /; according to EEPROM setting, the valid/used parameter set is selectable per BUS or per digital input DIN. Parameter set : open pin or applied voltage 5 to VDC; parameter set : bridge to GND or applied voltage < VDC KL 9 Din Digital input : Control characteristic of the integrated controller; according to EEPROM setting, the control characteristic of the integrated controller is normally/inversely selectable per BUS or per digital input; normal: open pin or applied voltage 5 to VDC (control deviation = actual sensor value - set value) inverse: bridge to GND or applied voltage < VDC (control deviation = set value - actual sensor value) KL Ain U Analogue input ; actual sensor value - V; Ri= kω; parametrisable curve; only usable as alternative to input Ain I KL + V Fixed voltage output VDC; + V +5/- %; max. ma; short circuit proof; power supply for ext. devices (e.g. sensors) KL Ain I Analogue input ; actual sensor value 4- ma; Ri= Ω; parametrisable curve; only usable as alternative to input Ain U KL 4 Aout Analogue output - V; max. 5 ma; output of the actual motor control factor (output voltage of electronics)/ of the actual motor speed; function selectable per bus; parametrisable curve. Item no Revision 6 Release --7 Page 4 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 () 8 8- Fax +49 ()

5 KG9-AR- Charts: Air flow Hz 9 5. rho=, kg/m³ qv [CFM]. 5..,6 pfs [Pa] ,4,,8,6,4,,8,6,4 pfs [InHO] Measurement: LU-49 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 47 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed ,,8,6, qv [m³/h] , Measured values U V f Hz n min P ed W I A LpA in LwA in LwA out qv m /h p fs Pa U = Supply voltage f = Frequency n = Speed P ed = Power input I = Current draw LpA in = Sound pressure level inlet side LwA in = Sound power level inlet side LwA out = Sound power level outlet side qv = Air flow p fs = Pressure increase Item no Revision 6 Release --7 Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 () 8 8- Fax +49 ()

EC centrifugal fan - RadiPac

EC centrifugal fan - RadiPac R3G31-AX54-21 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 8-0 Fax +49 (0) 7938 8-0 info@de.ebmpapst.com www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND S 1.1 Levels of hazard

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND S 1.1 Levels of hazard

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone: +49(0)7938/81-0 Fax: +49(0)7938/81-110 info1@de.ebmpapst.com www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND NOTES Please read these

More information

air comfort Centriflow 3D

air comfort Centriflow 3D Air Comfort air comfort Centriflow 3D Plug fan GMEC EC-motor» Operating instructions Content Page 1. Introduction... 2 2. Safety regulations and information... 2 3. Intended use... 4 4. Technical data...

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND INFORMATION 1.1 Hazard

More information

Encoders Absolute Singleturn Encoder Types A58CS8

Encoders Absolute Singleturn Encoder Types A58CS8 Types A58CS8 Sturdy design with hardened bearings High rotation speed -40...+80 C/-40...+76 F operating temperature range High shock and vibration resistance Magnetic field proof also available as explosion

More information

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H018M2 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 200..240V - 1ph Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase Product datasheet Characteristics ATV32HU30N4 variable speed drive ATV32-3 kw - 400 V - 3 phase - with heat sink Complementary Line current Apparent power Prospective line Isc Nominal output current Maximum

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink Characteristics variable speed drive ATV32-3 kw - 400 V - 3 phase - with heat sink Product availability : Stock - Normally stocked in distribution facility Price* : 937.00 USD Main Range of product Altivar

More information

Photoelectrics Retro-reflective Type PA18C.R..., DC

Photoelectrics Retro-reflective Type PA18C.R..., DC Photoelectrics Retro-reflective Type PA18C.R..., DC Miniature sensor range Range: 6.5 m (Axial), 5 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to

More information

Absolute encoders - SSI

Absolute encoders - SSI Features Encoder multiturn / SSI Optical sensing Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics Counting direction input Available

More information

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter Product data sheet Characteristics ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter Main Range of product Altivar 61 Product or component type Product specific application Component

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position) echnical data sheet EF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

Personal Service Global Reach

Personal Service Global Reach Personal Service Global Reach FAN MOTORS NMB Technologies Corporation (NMB Technologies Corporation Chatsworth, California) NMB Technologies Corporation is a subsidiary of NMB (USA) Inc., the North American

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANlift interface and optical sensor technology are the right encoders for all CANopen or CANlift applications. With a maximum resolution of

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 5868 and 5888 with interface and optical sensor technology are ideal for use in all applications with a interface. The encoder supports the isochronous (IRT) mode and is therefore

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Standard Frame Axial Fans

Standard Frame Axial Fans Quick reference guide Standard Frame Axial Fans 2007 Edition about Axair Fans UK Application knowledge : 20 years experience in air movement; from fume handling to refrigeration; from small electronic

More information

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA Characteristics phase control relay RM17-T - range 183..484 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Switching

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Power Supply HARTING pcon

Power Supply HARTING pcon HARTING pcon 2120 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10,...) o Accuracy class up to: 0.5 o Programmable input

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact Characteristics variable speed drive ATV320-0.55kW - 380...500V - 3 phase - compact Main range of product product or component type product specific application device short name format of the drive product

More information

Incremental encoders Solid shaft with EURO flange B pulses per revolution

Incremental encoders Solid shaft with EURO flange B pulses per revolution Solid shaft with EURO flange B 0 5000 pulses per revolution EIL580 - EURO flange B - OptoPulse Features Size ø58 mm Precise optical sensing Output signal level TTL or HTL EURO flange B Connection axial,

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

KNC-SRV-FD332S Servo Driver

KNC-SRV-FD332S Servo Driver FEATURES 88-126VAC Single Phase Input 750-1000 Watt Power Range Position, Speed, and Torque Control Communication Ports: RS232 and RS485 Communication Protocol: MODBUS 2500PPR Incremental Communication

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Safety Standards. Model Number:

Safety Standards. Model Number: PMC Highlights & Features Universal AC input range from 85Vac to 264Vac without power de-rating High operating ambient temperature, > 60 o C de-rating power High MTBF > 700,000 hrs. as per Telcordia SR-332

More information

AO561 Analog Output Module

AO561 Analog Output Module Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal

More information

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s SRQ24A Rotary actuator for ball valves orque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s echnical data Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V Nominal voltage range

More information

Non-communicating room controllers

Non-communicating room controllers 3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For

More information

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this Overview Signal converters Your process requires the utmost attention Our new signal conditioners support you in achieving this Many process parameters in your system are handled by your control system,

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

ebm-papst Product Selector 2011

ebm-papst Product Selector 2011 ebm-papst Overview Nomenclature PARAMETER ABBREVIATION UNITS input voltage U Volts input power Pe or P1 Watts fan speed n rpm or 1/min overall static efficiency η se or η_ges_fa % overall total efficiency

More information

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics 1x50 W Dimmable DALI LED driver Hybrid dimming technique for high quality light 50 W 220 240 V 0 / 50 Hz 60 Hz Suitable for use in emergency lighting applications DALI control input, 1 % - 100 % dimming

More information

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V orque min. 54 in-lb for control damper surfaces up to 12 sq ft. Application For proportional modulation of dampers in HVAC systems.

More information

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range) Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements

More information

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)

More information

E101 - Strain Gauge Transducer Display Module. Contents

E101 - Strain Gauge Transducer Display Module. Contents E101 - Strain Gauge Transducer Display Module Contents Torque Transducer Display Interface: TSE3249R Strain Gauge Transducer Display Interface [E101] Operating Guide: TSE2097V (Includes Introduction, Description

More information

IST ULTRASTAB Power Supply for high precision transducers

IST ULTRASTAB Power Supply for high precision transducers IST ULTRASTAB Power Supply for high precision transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±0 V voltage output (see

More information

Relative, and differential pressure transmitter type 699

Relative, and differential pressure transmitter type 699 Relative, and differential pressure transmitter type 699 Pressure range -1... 1 mbar / 0... 0.3 50 mbar The type 699 transmitters are available in switchable pressure ranges and with or without display.

More information

Pressure range mbar / mbar

Pressure range mbar / mbar Pressure range -1... 1 mbar / 0... 0.3 50 mbar Technical overview Pressure range Relative and differential Operating conditions Medium Temperature Tolerable overload on one side Rupture pressure Application

More information

em4 Accessories Digital expansions

em4 Accessories Digital expansions em4 Accessories Digital expansions Up to two digital / analog expansions can be added to the em4 nanoplc to expand up to 46 I/Os 6 digital / analog configurable inputs (0-10 VDC, 0-28.8 VDC, Potentiometer)

More information

The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document.

The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document. The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document. Rotary Encoder Solutions Limited Dutton Road Redwither Business

More information

Proportional relief valves type RZMO-A*

Proportional relief valves type RZMO-A* www.atos.com Table F007-9/E Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 440 size 06 Valve body Proportional solenoid Spring Poppet Integral electronics

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Switch Mode Power Supply S8VT 120/240/480/960 W Models Switch Mode Power Supply 120/240/480/960 W Models Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Photoelectrics Diffuse-reflective, Background Suppression Type PH18CNB20...

Photoelectrics Diffuse-reflective, Background Suppression Type PH18CNB20... Photoelectrics Diffuse-reflective, Background Suppression Type PH8CNB... Miniature sensor range Range: mm Sensitivity adjustment by potentiometer Modulated, red light 65 nm Supply voltage: to VDC Output:

More information

VLT Micro Drive. Ready Set Go!

VLT Micro Drive. Ready Set Go! Despite its compact size and ease of installation, the VLT Micro Drive can deliver exceptional performance even in complex applications. 1 Well protected IP20 enclosure with NEMA/UL Type 1 optional; no

More information

Provisional Product Information. ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Provisional Product Information. ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications Provisional Product Information ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications November 2007 ECN 1123/EQN 1135 Series Rotary encoders for safety-related applications With

More information

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF 3 Power Supplies GL Series: Single & Multi Output Switchers The new GL series provides a broad range of AC/DC power supply solutions that covers power ratings from 25 watts to 500 watts for use in various

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8696 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact

More information

Electronic earth leakage protection relay

Electronic earth leakage protection relay RGU 10 / RGU 10C Electronic earth leakage protection relay User manual Extended version M98203201_03_11A CIRCUTOR, SA Checks on receipt. This manual assists in the installation and use of the RGU-10/RGU-10C

More information

Voltage Transducer UMT516 / MT516

Voltage Transducer UMT516 / MT516 Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication

More information

N0524/N1024, N POS/N POS

N0524/N1024, N POS/N POS N0/N0, N00-POS/N00-POS NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING / -POSITION CONTROL PRODUCT DATA SPECIFICATIONS Supply voltage N0/N0 Vac/dc -%/+0%, 0/60 Hz N00-POS/N00-POS 0 Vac -%/+0%,

More information

User Manual. Solar Inverter for Water Pump

User Manual. Solar Inverter for Water Pump User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

BTL6-A_10-M -A1-S115. Data Sheet. english

BTL6-A_10-M -A1-S115. Data Sheet. english BT6-A_10-M -A1-S11 english Data Sheet Balluff GmbH Schurwaldstrasse 9 76 Neuhausen a.d.f. Germany Phone +49 (0) 71 8/1-0 Fax +49 (0) 71 8/0 10 Servicehotline +49 (0) 71 8/1-70 E-Mail: balluff@balluff.de

More information

EC-MOTOR » INSTALLATION AND MAINTENANCE

EC-MOTOR » INSTALLATION AND MAINTENANCE AIR COMFORT AIR TREATMENT 90 GB 017.11.09» INSTALLATION AND MAINTENANCE CONTENT Page 1. SAFETY REGULATIONS AND NOTES 1.1 Hazard levels of warnings 1. Staff qualification 1.3 Electrical voltage and current

More information

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog Low Voltage Drives ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog ABB Component Drive What is the ACS55 customer value? Reduces panel size Reduces commissioning, installation and energy

More information

QUINT-PS AC/24DC/10

QUINT-PS AC/24DC/10 Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs

More information

Data sheet: Wilo-Stratos 40/1-8

Data sheet: Wilo-Stratos 40/1-8 Data sheet: Wilo-Stratos 4/1-8 Pump curves 1 2 v 3 4 DN4 m/s,5 1, 1,5 2, 2,5 DN5 H/m Wilo-Stratos 4/1-8 p/kpa Wilo-Stratos 5/1-8 48 1 /min - 1 V 1~23 V - DN 4 / DN 5 8 8 P 1/W n= const 6 383 1 /min - 8

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

Issue 03/2013. The Electronic Load

Issue 03/2013. The Electronic Load Issue 03/2013 ZS Electronic Loads, PL Series Interface overview RS-232 USB / GPIB LAN System bus Analog X Analog isolated / X Standard ption / not available PL506 PL1006 Voltage Current Resistance 3) Model

More information

VARIABLE SPEED DRIVES

VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...30kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging

More information

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner GB Product Data Sheet 99.70.06-B AVM321S/AVM322S: 1000N Actuator with analog SUT positioner Areas of use For actuation of 2- and 3-way valves. For controllers with constant output (0...10 V / 4...20 ma)

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply Data sheet Power supply CP-E 24/0.75 Primary switch mode power supply The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply

More information

CM597 Ethernet Communication Module

CM597 Ethernet Communication Module Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008

More information

Data sheet: Wilo-Stratos 50/1-9

Data sheet: Wilo-Stratos 50/1-9 Data sheet: Wilo-Stratos 5/1-9 Pump curves H/m 2 5 1 15 2 1 v 1 2 3 1 41 1 /min-1 V 8 3714 1 /min-9 V 3329 1 /min-8 V 6 4 57 1 /min-6 V 2 4 6 P 1/W n= const 4 8 V 2 H/m 2943 1 /min-7 V 2171 1 /min-5 V

More information

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid

More information

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-D 12/2.1 Primary switch mode power supply Data sheet Power supply CP-D 12/2.1 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Linear Position Transducer HLT 1000-R2

Linear Position Transducer HLT 1000-R2 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and

More information

FD432S Series Servo Driver

FD432S Series Servo Driver FEATURES DESCRIPTION Input Voltage Range From 176-253VAC Rated Current is (RMS) 11A 1000-1260 Watt Power Range Position, Speed, and Torque Control RS232 & RS485 (LA) or RS232 & CAN BUS (AA/CA) Communication

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications Product Information ROC 425 ROQ 437 Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications 2/2016 ROC 425, ROQ 437 with synchro flange Rotary encoders for absolute position values with

More information