WAGO Kontakttechnik GmbH & Co. KG

Size: px
Start display at page:

Download "WAGO Kontakttechnik GmbH & Co. KG"

Transcription

1 0 WAG Kontakttechnik GmbH & Co. KG Project name: Project number: Drawing number: : Part number: CS_DE_00888_ CS_DE_00888 CD_AC_V LM min. AC_V_LM_min / Customer: WAG Kontakttechnik GmbH & Co.KG Hansastraße Acceptance: Manufacturer: WAG Kontakttechnik GmbH & Co. KG Hansastraße Minden : Minden Deutschland Deutschland +9 (0)/8- (fon) Signature: +9 (0)/8-0 (fon) +9 (0)/8-9 (fax) Customer number:kundennummer Stamp: Department: Projectservice international Person of contact: Herr Dirk Röscher info.projektservice@wago.com Created on:..0 from Handled on: from Number of pages: WAG is a registered trademark of WAG Verwaltungsgesellschaft mbh AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Title page / cover sheet =

2 0 Table of contents Column X: An automatically created page was manually reworked description Supplementary page field Edited by X / Title page / cover sheet / Table of contents / Revision control / Technical info / Technical info / Hints / Production hints =A+/8 Construction =A+/9 PLC-verview =A+/9. PLC-verview =A+/0 Power Supply =A+/ control voltage VDC DALI control voltage 8VDC =A+/ =A+/ =A+/ =A+/ =A+/ =A+/ =A+/8 =A+/9 =A+/0 =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+SN/ Controller Supply Controller Interface Digital Inputs Digital Inputs Digital utputs Digital utputs Relay Relay DALI-Master Terminal-strip overview : =A+-X0 - =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Terminal diagram =A+-X Parts list : WAG.9- - WAG AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Table of contents =

3 0 Revision overview Creator Revision name Revision description Production status AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Revision control =

4 0 Technical information: Miscellaneous Applied norms Brand: WAG Switchgear and controlgear assembly IEC 9- - General rules Type: Automation Cabinet IEC 9- - Power switchgear and controlgear assemblies (PSC) Measurements w/h/d: 0 x 80 mm IEC 9- - Distribution boards intended to be operated by ordinary persons (DB) Degree of protection: Protection class: IP0 I Boxes and enclosures for electrical accessories: IEC 00- Installation type Door hinge: mounting in enclosure without Miscellaneous Cable routing: above / below Ambient air temperature: 0 C bis C Relative humidity: - 9 % (moisture condensation and direct sun heat inadmissible) Special service conditions - Network configuration: Rated voltage (Un): Rated operatonal voltage (Ue): Rated insulation voltage (Ui): Rated impulse withstand voltage (UImp) Rated current (In) Rated current of a circuit (Inc) Rated peak withstand current (lpk) Rated diversity factor (RDF): Rated frequency (fn): TN-S/TT 0 VAC / VDC Ue (separated neutral conductors and protective conductors within the entire system) / 0 VAC / 00 VAC kv (ÜSK III) A please refer to circuit plan The switchgear and controlgear assembly is designated for electronic installations with either a prospective short-circuit current not rising above 0 ka or a protection by current limiting protective devices with a maximum switch-off current of ka. 0,9 0 Hz Year of construction 0 Electromagnetic compatibility (EMC): Environment A This product is appropriate for environment A. Unwanted electromagnetic disturbances may be caused in environment B; in this case, the user can be obliged to take the appropriate steps AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Technical info =

5 0 Technical information: Conductor colours according to EN 00- (DIN IEC0) Conductor cross-sections (H0/H0V-K) Load circuits External conductor black BK Cross-section for at least % of the rated current (circuit) Minimum requirement: Neutral conductor N blue BU Load circuits 0V/00VAC min. mm² Protective earth conductor PE green-yellow GNYE Control power Signal voltage min. 0. mm² min. mm² Control power: 0VAC (L) red RD 0VAC (N) red/-white RDWH Enclosure grounding Details are primarily shown in the diagram! min.. mm² (depending on the external conductor) VAC 0VAC brown brown/-white BN BNWH VDC 0VDC dark blue dark blue/-white DKBU DKBUWH External voltage Analog-/measurement signal orange white G WT DALI violet VT Serial interface RS/8 grey GY SMI turquoise TQ Further bus applications pink PK KNX/LN J-Y(ST)Y xx0.8 mm green AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Technical info =

6 0 Hints for switchgear and controlgear combination (SGC): Electric connection: The switchgear and controlgear assembly can only be opened, installed, connected, serviced and started up by skilled persons (according to IEC 9- section.. respectively DIN VDE 00 part 00). Circuit diagram: All switch contacts are shown in a disconnected off-mode. Upon connecting the switchgear and controlgear assembly as well as other external field devices, it is essential to comply with the relevant VDE-regulations, the manufacturers' guidelines as well as the local or national regulations. The switchgear and controlgear assembly is designated to be used for the public low-voltage power supply network. The system voltage has to correspond with the nominal voltage of the switchgear and controlgear assembly and must be within the defined limits for voltage ranges as defined in the VDE-regulations.. In case of a three-phase A.C. current supply, a right rotating field has to be taken care of. Fusing of the switchgear and controlgear assembly is done on site in consideration of the given nominal current (page ) and the local or national regulations. In order to avoid failures, all bus and control cables have to be installed separately from other power supply cables carrying system voltage. Hints for CE-labelling: All switching devices and components built into the switchgear and controlgear assembly are CE-labelled, subject to the condition that those devices require this type of labelling. The switching devices and components meet the requirements of the EC-directives regarding low-voltage, switching devices and components as well as electromagnetic compatibility Starting up: Before starting-up of the switchgear and controlgear assembly, all terminal and screw connections must be checked for tight fighting and retightened if needed, in accordance with VDE 0.. Motor protection switches, overcurrent relays etc. have to be set to the respective nominal currents and documented Within the process of starting-up, live cables must be checked in respect of insulation faults and fracture points If the enclosure needs to be opened after the start-up, it must be disconnected from voltage beforehand. The inspection of cable lengths and cross-sections supplying consumer-, command- and monitoring devices must be performed by the installation company/start-up engineer. (DIN VDE 000 part 0 and VDE 098 part ). The cable cross-sections shown refer to minimum cross-sections without considering external cable lengths. All potentially listed cable cross-sections and cable types should be regarded as suggestions When starting up, all functions have to be checked as well as documented. We would like to indicate that after reconstructing or substantially changing the electric installations, an initial testing according to VDE will have to be made, before the user is allowed to conduct a start-up. This inital testing has to be performed by a skilled person being competent to perform such a testing. The initial testing is not part of our performance. We would be more than happy to give you the details of a specialist electric company which can perform the neccessary testing for you Duplicating and/or passing this diagram to any third party without an explicit written permission by WAG Kontakttechnik GmbH & Co. KG is not allowed and may lead to prosecution. Any noncompliance commits to compensation. All rights are reserved in case of granting a patent or applying for a utility model registration. Any amendments or extensions conducted without written permission by WAG Kontakttechnik GmbH & Co. KG will lead to expiration of all types of guarantees AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Hints =

7 AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Production hints = =A+/8

8 0 0 0er - 90mm -9K -9K -9K -9K U U SYS RUN RST U U U I/ MS NS 8 8 U USR -T -9K K -K -K -K -K -K -K -K8 -K -K -K -K -K -K -K -K8 0-80/ er - 90mm -X0 -T -X -X 0er - 0mm -X L N PE INPUT UTPUT 8- ADJ. DC K er - 0mm =+/ AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Construction 9 8

9 U SYS RST U RUN U I/ U MS U NS U USR 0-80/ K /. /9..0 /. -9K /. /. /9..0-9K /. /. /9.. -9K /0. /9.. -9K AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + PLC-verview 9. 9

10 0-9K 0-80/000-0 SPS - Controller PFC00 Lightmanagement V /. 0V /. V /. V /. 0V /. 0V /. FE /. FE 8 /.8 X RJ /. X RJ /. X RS/8 /. V 0V V V 0V 0V FE FE RJ_ RJ_ RS/8-9K 0-0 -channel digital output module Q0.0 D /. Q0. D /. Q0. D /. Q0. D /. Q0. D /. Q0. D /. Q0. D /. Q0. D8 8 /.8 Q.0 D9 9 /. Q. D0 0 /. Q. D /. Q. D /. Q. D /. Q. D /. Q. D /. Q. D /.8 -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K8:A -K:A -K:A -K:A -K:A -K:A -K:A -K:A -K8:A DALI () powersupply on/off D D D D D D D8 D9 D0 D D D D D D -9K 0-0 -channel digital input module I0.0 DI /. I0. DI /. I0. DI /. I0. DI /. I0. DI /. I0. DI /. I0. DI /. I0. DI8 8 /.8 I.0 DI9 9 /. I. DI0 0 /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /. I. DI /.8 -X: -X: -X: -X:8 -X:0 -X: -X: -X: -X:8 -X:0 -X: -X: -X: -X:8 -X:0 -X: Master on/off construction site operation (pushbuttoninput) DI DI DI DI DI DI DI8 DI9 DI0 DI DI DI DI DI DI -9K - DALI Multi-Master mudule +DALI /0. -DALI /0. +U /0. -U /0. +DALI /0. -DALI /0. +U /0. -U 8 /0.8 DALI-Master DALI-Master supply + supply AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + PLC-verview 0 9.

11 0 L /.0 N /.0 PE_a /.0 PE_c /.0 PE -X0 L L N N PE PE Supply 0 V AC, 0 Hz AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Power Supply 0

12 0 0.9 / L 0.9 / N -T L N PE -T L N 8- Primary switch mode Power supplies utput voltage DC V. A 8-00 Primary switch mode power supplies DC 8 V /. A V 8V DC+ DC+ DC+ DC+ DC- DC- DC- DC- -K /. DALI+ / 0. DALI- / 0. VDC /.0 0VDC / / PE_a control voltage V DC DALI control voltage 8 V DC AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + control voltage VDC DALI control voltage 8VDC

13 0.9 / -VDC -VDC /.0-9K / /000-0 SPS - Controller PFC00 Lightmanagement Part of V 0V V V 0V 0V FE FE 8.9 / 0VDC 0VDC / / PE_c V 0V V V 0V 0V FE FE AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Controller Supply

14 0-9K / /000-0 SPS - Controller PFC00 Lightmanagement Part of RJ X RJ X RS/8 X RJ_ RJ_ RS/ AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Controller Interface

15 0-9K / channel digital input module Part of DI I0.0 DI I0. DI I0. DI I0. DI I0. DI I0. DI I0. DI8 I / -VDC -VDC /.0 -X Master on/off construction site operation (pushbuttoninput) DI DI DI DI DI DI DI AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Digital Inputs

16 0-9K / channel digital input module Part of DI9 I.0 DI0 I. DI I. DI I. DI I. DI I. DI I. DI I / -VDC -X DI9 DI0 DI DI DI DI DI DI AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Digital Inputs

17 0-9K / channel digital output module Part of D Q0.0 D Q0. D Q0. D Q0. D Q0. D Q0. D Q0. D8 Q0. 8 -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K8 DC V A A.9 / 0VDC 0VDC /.0 WAG.88- /. WAG.88- /8. WAG.88- /8. WAG.88- /8. WAG.88- /8. WAG.88- /8. WAG.88- /8. WAG.88- /8.8 DALI () powersupply on/off D D D D D D D AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Digital utputs

18 0-9K / channel digital output module Part of D9 Q.0 D0 Q. D Q. D Q. D Q. D Q. D Q. D Q K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K DC V A A -K8 DC V A A.9 / 0VDC WAG.88- /9.0 WAG.88- /9. WAG.88- /9. WAG.88- /9. WAG.88- /9. WAG.88- /9. WAG.88- /9. WAG.88- /9.8 D9 D0 D D D D D D AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Digital utputs 8

19 0 -K -K -K -K -K -K -K8 /. /. /. /. /. /. /.8 -X D D D D D D D AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Relay 9 8

20 0 -K -K -K -K -K -K -K -K8 /. /. /. /. /. /. /. /.8 -X D9 D0 D D D D D D AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Relay 0 9

21 0-9K /9. - DALI Multi-Master mudule +DALI +DALI -DALI -DALI +U +U -U -U 8.9 / DALI+.9 / DALI- -X DALI-Master DALI-Master supply + supply AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + DALI-Master =REP+KLP/ 0

22 0 Terminal-strip overview Terminal strip Terminal strip definition text Terminals first last Total PE Total N Total number Graphic page of terminal diagrams =A+-X0 =A+-X =A+-X =A+-X Supply 0 V AC Digital Inputs 0 0 Digital utputs DALI-Master =REP+KLP/ =REP+KLP/ =REP+KLP/ =REP+KLP/ =A+/ AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Terminal-strip overview : =A+-X0 - =A+-X = REP KLP

23 0 Terminal diagram Cable name Terminal diagram =A+-X0 Supply 0 V AC Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column Supply 0 V AC, 0 Hz T L /0.0 = 00-0 /0. = T N /0. = 00-0 /0. = T;-9K PE; /0. = 00-0 / AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Terminal diagram =A+-X0 = REP KLP

24 0 Terminal diagram Cable name Terminal diagram =A+-X Digital Inputs Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column Master on/off construction site operation (pushbuttoninput) K /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = 8-9K /. DI /. = 0-9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI8 00- /.8 = -9K 8 /.8 Spare 00- /. DI9 8-9K 9 /. DI /. = 0-9K 0 /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = -9K /. DI 00- /. = 8-9K /. DI /. = 0-9K /. DI 00- /.8 = -9K / AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Terminal diagram =A+-X = REP KLP

25 0 Terminal diagram Cable name Terminal diagram =A+-X Digital utputs Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column D 00- -K /8. = -K /8. D 00- -K /8. = -K /8. D 00- -K /8. = -K /8. D 00- -K /8. = 8 -K /8. D K /8. = 0 -K /8. D 00- -K /8. = -K /8. D K8 /8.8 = -K8 /8.8 D K /9. = -K /9. D K /9. = 8 -K /9. D K /9. = 0 -K /9. D 00- -K /9. = -K /9. D 00- -K /9. = -K /9. D 00- -K /9. = -K /9. D 00- -K /9. = 8 -K /9. D K8 /9.8 = 0 -K8 / AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Terminal diagram =A+-X = REP KLP

26 0 Terminal diagram Cable name Terminal diagram =A+-X DALI-Master Cable name Function text Cable type Target designation Connection point Terminal Jumper Type of terminal Target designation Connection point Cable type / column DALI-Master K /0. = - -9K / AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Terminal diagram =A+-X +SN/ = REP KLP

27 0 Parts list Device tag Quantity Designation Manufacturer Type number ERP number Part number (eplan) -0 Screwless end stop WAG WAG Screwless end stop WAG WAG Screwless end stop WAG WAG Screwless end stop WAG WAG Screwless end stop WAG WAG Screwless end stop WAG WAG Screwless end stop WAG WAG Screwless end stop WAG WAG Screwless end stop WAG WAG Screwless end stop WAG WAG.9- -9K0 End module WAG WAG K SPS - Controller PFC00 Lightmanagement WAG 0-80/ / WAG.0-80/ K SD memory card WAG 8-89/ / WAG.8-89/ K -channel digital input module WAG WAG K -channel digital output module WAG WAG K DALI Multi-Master mudule WAG WAG.- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K8 WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K WAG WAG.88- -K8 WAG WAG.88- -T Primary switch mode Power supplies WAG WAG.8- -T Primary switch mode power supplies WAG WAG X0 -conductor through terminal block WAG WAG X0 -conductor through terminal block WAG WAG X0 -conductor ground terminal block WAG WAG X0 End and intermediate plate WAG WAG X Multilevel installation terminal block WAG WAG.00- -X End and intermediate plate WAG WAG X Multilevel installation terminal block WAG WAG.00- -X End and intermediate plate WAG WAG X Multilevel installation terminal block WAG WAG.00- -X End and intermediate plate WAG WAG KLP/ AC_V_LM_min Project no.:cs_de_00888_ Draw. no.: CS_DE_00888 CD_AC_V LM min. + Parts list : WAG.9- - WAG.00-9 = REP SN

WAGO Kontakttechnik GmbH & Co. KG

WAGO Kontakttechnik GmbH & Co. KG 0 WAG Kontakttechnik GmbH & Co. KG Project name: Project number: Drawing number: : Part number: CS_DE_00_ CS_DE_00 CD_AC_V LM max. AC_V_LM_max 00-000/000-000 Customer: WAG Kontakttechnik GmbH & Co.KG Hansastraße

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

UTME 6. Extract from the online catalog. Order No.:

UTME 6. Extract from the online catalog. Order No.: Extract from the online catalog UTME 6 Order No.: 3047400 Test disconnect terminal block, Connection method: Screw connection, Cross section: 0.2 mm² - 10 mm², AWG: 24-8, Width: 8.2 mm, Color: gray, Mounting

More information

ASI QUINT /2.4 EFD

ASI QUINT /2.4 EFD Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678

More information

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

ISOMETER isopv with coupling device AGH-PV

ISOMETER isopv with coupling device AGH-PV Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for photovoltaic plants up to AC 793 V/DC 1100 V Vorläufiges Datenblatt IsoPV_D00024_02_D_XXEN/07.2018 ISOMETER with coupling

More information

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K .2 X X testregistrierung TROXNETCOM AS-i Communication interface between a component and the controller The module is used to connect the control system with the components Integral AS-Interface slave

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

Decentralised operating and monitoring systems

Decentralised operating and monitoring systems MB-BAC-WA 1/4.3 X X MB-BAC-WA 1/4 testregistrierung Decentralised operating and monitoring systems Type MB-BAC-WA 1/4 Communication interface for exchanging variables via BACnet or Modbus Functional modules

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

IBS IL 24 BK RB-T-2MBD

IBS IL 24 BK RB-T-2MBD IBS IL 24 BK RB-T-2MBD INTERBUS Inline Terminal for Connecting a Remote Bus Branch Data Sheet 6766A 01/2003 $! $ * This data sheet is only valid in association with the "Configuring and Installing the

More information

ISOMETER isoev425 with coupling device AGH420

ISOMETER isoev425 with coupling device AGH420 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device

More information

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Manual -ENGLISH- Page 1 KWG-ISO Page 1 KWG-ISO Operating manual English- Status May 2013 Page 2 Manufacturer address KW-Generator GmbH & Co.KG Bänglesäcker 24 73527 Schwäbisch-Gmünd / Lindach Phone: +49 (0) 7171 104 17 0 Fax: +49 (0)

More information

Datasheet - SLB 200-C04-1R

Datasheet - SLB 200-C04-1R 14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/40 Order No.: 2866242 Uninterruptible power supply 24 V/40 A. In the download area, there is a clearly arranged selection table available with load currents

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

QUINT-PS/24DC/48DC/ 5

QUINT-PS/24DC/48DC/ 5 Extract from the online catalog QUINT-PS/24DC/48DC/ 5 Order No.: 2320128 QUINT DC/DC converter, primary-switched, input: 24 V DC, output: 48 V DC/5 A Commercial data GTIN (EAN) sales group Pack Catalog

More information

Access Terminal IF-800

Access Terminal IF-800 95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller

More information

DEK-REL- 5/I/1. Extract from the online catalog. Order No.:

DEK-REL- 5/I/1. Extract from the online catalog. Order No.: Extract from the online catalog DEK-REL- 5/I/1 Order No.: 2941183 The illustration shows the version DEK-REL- 24/I/1 Relay terminal block, with soldered-in miniature relays, contact (AgNi +Au): small to

More information

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples... 8 Appendix 8.1 Wiring examples...3 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126006- / H / 2017-11-17 / AE-Nr. 8410 Content 1 About

More information

VAV compact controller GDB181.1E/3 GLB181.1E/3

VAV compact controller GDB181.1E/3 GLB181.1E/3 s 3 544 OpenAir VAV compact controller DB181.1E/3 LB181.1E/3 Series E Compact controllers for plants with variable or constant airflow Integrated high-accuracy differential pressure sensor, actuator, and

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

VAV modular controller

VAV modular controller s 3 545 OpenAir VAV modular controller Series E ASV181.1E/3 Modular controller for plants with variable or constant air volume flow Integrated high-accuracy differential pressure sensor and configurable

More information

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)

More information

Rhino PSM Power Supplies. Operating Instructions

Rhino PSM Power Supplies. Operating Instructions Rhino PSM Power Supplies Operating Instructions RHINO Power Supplies PSM Series Description The PSM power supplies are built-in units. The mounting position for PSM power supplies must fulfill the requirements

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green 22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

QUINT-PS/ 1AC/24DC/20/CO

QUINT-PS/ 1AC/24DC/20/CO Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective

More information

Datasheet - SRB 402EM-24V

Datasheet - SRB 402EM-24V Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0 RECTIFIER PSR380 (48V VERSION) USER MANUAL Page 2 (20) Notes to this manual ATTENTION! Read this manual very carefully before installing and commissioning the specified module. This manual is a part of

More information

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery

More information

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content 1. About this document DE Betriebsanleitung...............Seiten 1 bis 6 Übersetzung der Originalbetriebsanleitung 1.1 Function This operating instructions manual provides all the information you need

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet

More information

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.:

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.: Extract from the online catalog PLC-RSC- 24UC/21 Order No.: 2966184 The illustration shows the version PLC-RSC-24DC/21 PLC relay, consisting of base terminal block PLC-BSC.../21 with screw connection and

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

CONTROL PANEL WIRING SPECIFICATIONS

CONTROL PANEL WIRING SPECIFICATIONS CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B

More information

Earth-fault Relay SPAJ 110 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral

More information

QUINT-PS AC/24DC/10

QUINT-PS AC/24DC/10 Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

Sync Control for Eaton 9395P and 93PM User s and Installation Guide

Sync Control for Eaton 9395P and 93PM User s and Installation Guide Sync Control for Eaton 9395P and 93PM IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that you should follow during installation and maintenance of the

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Datasheet - SRB 301LC/B-24V

Datasheet - SRB 301LC/B-24V 27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush

More information

Safe switching and monitoring Non-Contact Safety Sensors

Safe switching and monitoring Non-Contact Safety Sensors Safe switching and monitoring Non-Contact Safety Sensors Electronic safety sensors are used to detect guard door closure. These sensors use noncontact operating principles (pulse echo or RFID) that limits

More information

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.:

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.: Extract from the online catalog DEK-OV- 5DC/ 24DC/ 3 Order No.: 2941361 The illustration shows the version DEK-OV- 24DC/24DC/3 Power optocoupler terminal block, input: 5 V DC, output: 3-30 V DC/3 A, terminal

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content 8 Appendix 8.1 Wiring examples...3 8.2 Integral System Diagnostics (ISD)....4 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101172890-

More information

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent

More information

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable 70 Series - Line monitoring relay 70 Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet Modulating damper actuator for adjusting air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx 08 m orque Nm

More information

Safety hinge switches HX series

Safety hinge switches HX series Safety hinge switches HX series Application field Pizzato Elettrica widens its own range of products making a new series of safety switches hinge-shaped HX series, where safety and style are melted in

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AR- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 8 8- Fax +49 8 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

Rotary version, three-position control

Rotary version, three-position control 4 622 Residential Air damper actuators GXD..31.1 Rotary version, three-position control Electric motor-driven actuators for three-position control 1.5 Nm nominal torque AC 24 V or AC 230 V rated voltage

More information

Version 5 Controls for natural ventilation. WUF 110 / 121 / 150 Actuator interfaces

Version 5 Controls for natural ventilation. WUF 110 / 121 / 150 Actuator interfaces Version 5 Controls for natural ventilation WUF 110 / 121 / 150 Actuator interfaces 6.05 WUF 121 WUF 110 WUF 150 Application the motor interface is used for individual operation of a ±24V DC actuator from

More information

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

TOPJOB S Sensor/Actuator Terminal Blocks Pluggable Signal Level with Push-in CAGE CLAMP Reliability

TOPJOB S Sensor/Actuator Terminal Blocks Pluggable Signal Level with Push-in CAGE CLAMP Reliability TOPJOB S Sensor/Actuator Terminal Blocks Pluggable Signal Level with Push-in CAGE CLAMP Reliability TOPJOB S SEND THE RIGHT SIGNALS For the very first time, sensor/actuator wiring is pluggable between

More information

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

For Sales and Support call KMParts.com (866)

For Sales and Support call KMParts.com (866) Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

MCX08M2 Programmable controller

MCX08M2 Programmable controller Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

preliminary ISOMETER isoev425 with coupling device AGH420 Preliminary datasheet

preliminary ISOMETER isoev425 with coupling device AGH420 Preliminary datasheet with coupling device GH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary edition Preliminary datasheet TD106038en /.2012 with coupling device

More information