Vibrometer Introduction
|
|
- Imogen Dorsey
- 6 years ago
- Views:
Transcription
1
2 Introduction Hysen 5
3 OFV Series OFV-5000 Modular Controller VD/DD Decoder Guide-Line Velocity Decoder Decoder Description No.of Ranges Best Resolution Max.Velocity Upper Freq. Limit VD-01 High linearity velocity decoder m/s 50kHz VD-02 Wide-bandwidth velocity decoder m/s 1.5MHz VD-04 Mid-frequency velocity decoder m/s 250kHz (prerequisite to DD-400) VD-05* 10 MHz velocity decoder for ultrasonics 2 ** 5m/s 10MHz VD-06*** Digital high-precision velocity decoder m/s 350kHz General Specifications Ambient temperature Storage temperature Relative humidity 20%...80%, non-condensing Power supply Switch mode power supply with wide range input 100V V Weight 9.7kg Dimensions [W H L] 450mm 360mm 145mm(19 housing) Interface RS-232 Display Illuminated graphics LCD with menu assistance Outputs analog On the front : Velocity out, Displacement out, DSP out, Auxiliary out ; On the back : Signal level out Outputs digital S/P-DIF optical and electrical Sensor Head Compatibility Standard single point sensor heads OFV-505, OFV-503 Fiber optic sensor heads OFV-551, OFV-552 Compact sensor heads OFV-534 Displacement Decoder Decoder Description No.of Ranges Best Resolution Max.Displacement Frequency Range DD-100 Basic displacement decoder 8 80nm 82mm 0Hz-250kHz (requires any velocity decoder) DD-200 High-resolution displacement decoder 13 2nm 82mm 0Hz-250kHz (requires any velocity decoder) DD MHz displacement decoder for ultrasonics 2 0.1pm 75nm 50kHz-20MHz (requires any velocity decoder) DD-400 Integrating displacement decoder 3 ** ** 20Hz-250kHz (requires VD-04) DD-500* Digital high-end displacement decoder 16 15pm 50mm 0Hz-350kHz (requires VD-06) DD-600* I&Q converter for data processing with Vibsoft VDD Recommended Decoder Combinations VD-01 DD-200 Measurement of velocity and displacement up to 50 khz vibration frequency. General applications, e.g. acoustics, mechanical and automotive engineering VD-02 DD-200 Same as VD-01/DD-200, but vibration frequency range extended up to 1.5MHz VD-06* DD-500 Digital, high-precision measurement of velocity and displacement at frequencies up to 350 khz with velocity range limited to 0.5m/s. Demanding applications e.g. acoustics, micro systems, precision mechanics 6 Hysen 7
4 OFV Series OFV-505 Standard Optic Sensor Head OFV-551 / OFV-552 Fiber Optic General Specifications Operating temperature range Relative humidity 20%...80%, non-condensing Weight 3.4kg Dimensions [W H L] 120mm 80mm 345mm Laser wavelength 633nm, visible laser beam Laser protection class Class ll He-Ne laser, <1mW, eye-safe *Auto Focus OFV-505 : standard / OFV-503 : not available Maximum stand-off distance >300m(with OFV-SLR, surface dependent) Coherence maxima 234mm+n 204mm; n=0,1,2,3,... measured from the focusing ring *Depending on the surface properties OFV-505 and OFV-503 Interchangeable Lens Options-Technical Data Front lens OFV-SR OFV-MR OFV-LR* OFV-SLR short range mid range long range super long range Focal length [mm] Min. stand-off distance [mm] Size of focal point in at 100mm mm mm mm mm mm mm distance Each additional meter plus [ ] *Default configuration General Specifications Ambient temperature Storage temperature Relative humidity 20%...80%, non-condensing Housing protection IP 40 standard (NEMA 1) Dimensions 235mm 355mm 140mm (92.5 in x 14 in x 5.5 in) Weight 8kg Power max. 15W OFV-551 / OFV 552 Optics Specifications Laser wavelength 633 nm, visible red laser beam Laser protection class Class 2 He-Ne laser, < 1mW, eye-safe Available fiber lengths 1000 mm (OFV-551), 2000 mm, 3000 mm (OFV-552) Light Intensity control Optional laser power dimmer Coherence Properties Sensor head Maxima of Visibility OFV mm 1 + n 204 mm; n = 0; 1; 2;... OFV mm + n 204 mm OFV mm + n 204 mm 1 also 33 mm on request, 2 differntial measurement, 3 single point measurement 8 Hysen 9
5 PSV Series PSV-400 Scanning PSV-400-3D Scanning Hardware Accessories PSV-A-420 Geometry Scan Unit PSV-A-410 Close-up Unit PSV-A-430 Acoustic Gate Unit PSV-A-T18 Vertical Test Stand PSV-A-T11 Pan/Tilt Head Laser-based distance sensor for the direct optical acquisition of 3-D geometry data from the sample under test For close-up measurements, particularly on small parts Activates the gate input if a noise exceeds a certain threshold (e.g. for enabling brake squeal measurements) Motorized positioning of PSV scan head for small part testing (e.g. HDD, DVD, etc.) Motorized pan/tilt head for remote-controlled positioning the PSV scan head. PSV-A housing for the Data Management System, System Cabinet Controller and Junction Box PSV-A-408 Software Option Accessory package providing 4 additional Channels with ICP (for H-systems only) Geometry Data import, Time domain data, Data export to ME scope General Specifications Working distance >0.4m to about 100m ( 80mm accessible by using colse-up unit) Laser class Class 2 He-Ne laser, 633nm (visible beam), <1mW, eye-safe Sample size Several mm 2 up to m 2 range PSV-I-400 Contains vibrometer sensor model OFV-505, high precision scan unit, Sensor Head color video camera with Auto Focus and 72 X Zoom OFV-5000 Equipped with analog (PSV-400-B) and additional digital velocity decoders M2-20: with analog displacement decoder); Controller Velocity ranges: 10 to 1000 mm/s/v (analog); 1 to 50 mm/s/v (digital); 0.2mm/s/V to 50 mm/s/v (digital, H-Systems and PSV-400-3D) PSV-W-400 Industrial PC equipped with DVD-Recorder, 19 LCD Display, 100MB Ethernet Data Manage- network connection, signal generator, hardware for data acquisition, ment System and operating system Windows XP PSV-400 Configurations PSV-400-B PSV-400-H4 PSV-400-H4-S PSV-400-M2 PSV-400-M4 PSV-400-M2-20 PSV-400-3D Basic Scanning, 2 channels, 40 khz, 10 m/s High End Scanning, 4 channels (8 optional), 80KHz, 10 m/s High Velocity Scanning, 4 channels (8 optional), 80KHz, 20 m/s Wide Bandwidth 2 Channel Scanning 2 channels, 1 MHz, 10 m/s Wide Bandwidth 4 Channel Scanning, 4 channels, 1 MHz, 10 m/s 20MHz Scanning, 2 channels, 20 MHz, 10 m/s 3D measuring High End Scanning, 8 channels, 80 KHz, 10 m/s 10 Hysen 11
6 Micro Sys tem Series MSV-400 Microscope Scanning PMA-400 Planar Motion Analyzer MSV-400 System Configurations MSV-400-M2 MSV-400-M-20(A) MSV-400-M2-20(B) MSV-100 Microscope Scan Unit Optical sensor head Standard Configuration, Bandwidth 1MHz, 2MHz optional HF Configuration with high frequency velocity decoder, Bandwidth 10MHz HF Configuration with high frequency displacement decoder, Bandwith 20MHz Standard : OFV-551 single-fiber (see separate datasheet) Optional : OFV-552 dual-fiber with reference mirror Laser safety class <1 mw visible output(class 2) Beam diameter 10 with 4X microscope lens~1 with 40X microscope lens Scanners Scanner resolution Closed loop, dual-piezo scan stage >200x200 points within field of view Video Camera digital progressive scan camera (1.3 Mpixel) with FireWire interface(ieee 1394) Viewing field Approx. 2.5mm x 1.75mm with 4X lens, Approx. 100 x 70 with 100X lens Scan field Connection to microscope Recommended Microscopes 1.75 x 1.75mm with 4X lens, 70 x 70mm with 100X lens Via CCD port(c-mount) Mitutoyo FS70 Series, Zeiss Axioskop 2Mat Series, Olympus BX2M Series, Leica DMLM Series PMA-400 Technical Data System output -Displacement data -Step-response plots -Bode diagrams - Ring-down plots Frequency range Hz to 1MHz Resolution/max. amplitude Displacement resolution(nm) Peak-to peak motion amplitude(in-plane, ) 5x microscope magnification x microscope magnification x microscope magnification x microscope magnification x microscope magnification x microscope magnification Strobe exposure time(time resolution) 50ns Max. strobe jitter 25ns Precision of khz 0.2mrad(0.01, resp.) Precision of khz 0.02rad(1.1, resp.) Precision of MHz 0.2rad(11.5, resp.) Maximum velocity >0.1m/s to 10m/s(magnification dependent) Maximum allowed tilt 21 (magnification dependent) Maximum allowed piston 50 (maginification dependent) displacement(out-of-plane) 12 Hysen 13
7 Micro System Series Digital MSA-400 Micro System Analyzer VDD Digital Front End Specifications VDD-E-600 Stand-Alone Digital Front End Dimensions (H x W x D) 135 mm x 335 mm x 235 mm (5.3 x 13.3 x 9.3 in.) Weight 7 kg Operating temperature ( ) DD-600 Digital Board Set for OFV-5000 Controller Output EXT.DEC connector on rear of OFV-5000 controller VDD System Performance Specifications Max. velocity 405 mm/s or 810 mm/s; depends on sample frequency/sample time Frequency range MHz Maximum FFT lines 12,800 Maximum samples Time mode: 524,288 FFT mode: 32,768 Maximum displacement error 1% of RMS reading for 1 nm to 100 nm, 0.2% of RMS reading for displacements > 100 nm Total harmonic distortions < 0.1 % up to 50 khz sinusoidal Amplitude frequency response Displacement: typ. 0.1% Velocity: typ. 0.2% Acceleration: typ 0.2% Spurious signals <10 pm for 0 Hz < f 20 khz, 150 pm for 20 khz < f 2 MHz Displacement resolution* < 1 pm Velocity resolution 0.25 khz; 2.5 khz; 25 *Resolution is defined as the signal amplitude at which the signal-to-noise ratio is 0dB in a 1 Hz spectral bandwidth (RBW) measured on 3M Scotchlite Tape 14 Hysen 15
8 Special s Rotational New Compact Sensor Head In-Plane CLV Compact Laser 3D Laser HSV-2002 High Speed 16 Hysen 17
9 Portable & Industrial Topography System PDV-100 Portable Digital Topmap TMS-500/600/650 IVS-300 /IVS-200 Industrial Vibration Sensor Hardware Three measurement areas 7 10mm 2 ( ) (Software selectable) Lateral Resolution(12 ) 15 20mm 2 ( ) Lateral Resolution(26 ) 30 40mm 2 ( ) Lateral Resolution(50 ) Depth of measurement Up to 45mm(1.77 ) Height Resolution(z-axis) -10nm(depends on surface roughness) Dimensions cm 2 ( ) Topcam TMS-300/320 Electrical Power Weight VAC 45kg(99 lbs.) 18 Hysen 19
10 Vibration Various tools for Vibration Vibration Range of Vibrations Vibsoft Version Specification VIBSOFT-SP VIBSOFT-80 VIBSOFT-84 VIBSOFT-1000 VIBSOFT-1004 VIBSOFT-M2-40 VIBSOFT-FC VIBSOFT-VDD No. of Channels 1(S/P-DIF) Acquisition Bandwidth 18.75kHz 80kHz 80kHz 1MHz/2MHz 1MHz/2MHz/ 40MHz 100MHz 2MHz optional optional Internal Generator VIB-S-SIG-B VIB-S-SIG-M VIB-S-SIG-M VIB-S-SIG-M40 VIB-S-SIG-M Ext. HP Gen. (SW control) VIB-S-ExtSig VIB-S-ExtSig VIB-S-ExtSig VIB-S-ExtSig VIB-S-ExtSig VIB-S-ExtSig Gen. Channels Internal Generator Bandwldth 20kHz 80kHz 500kHz 500kHz 40kHz 100kHz 500kHz Trigger IN Gate IN Sync Out Clock IN ICP Support FFT-lines Zoom FFT SAX Basic Engine UFF-Export ME scope Exprot : included : Option : Not available From left to right: OFV-C-102 and OFV-130 heads CLV-039 Flexible Arm Quick Analyzer & Quick Check OFV-035 XY Traverse Stage OFV-036 Miniature head holder OFV-036-M Tip/Tilt device OFV-T-031 Test Stand PSV-A-T18 Vertical Test Stand 20 Hysen 21
11
Dual Fiber SWIR Laser Doppler Vibrometer
Dual Fiber SWIR Laser Doppler Vibrometer The OptoMET Dual Fiber SWIR Vibrometer consists of a SWIR vibrometer and a flexible Dual-Fiber head, different objective lenses either collimated or focused are
More informationOFV-2500 Vibrometer Controllers
OFV-2500 Vibrometer Controllers POLYTEC INDUSTRIAL VIBROMETERS OFV-2500 Series Vibrometer Controllers OFV Series Sensor Heads CLV-2534 Compact Laser Vibrometer IVS-200 Industrial Vibration Sensor IVS-300
More informationCLV-2534 Compact Laser Vibrometer
CLV-2534 Compact Laser Vibrometer POLYTEC INDUSTRIAL VIBROMETERS OFV-2500 Series Vibrometer Controllers OFV Series Sensor Heads CLV-2534 Compact Laser Vibrometer IVS-200 Industrial Vibration Sensor IVS-300
More informationPolytec Industrial. Vibrometer. Advancing Measurements by Light
Data Sheet CLV-2534 Compact Laser Vibrometer Polytec Industrial Vibrometers OFV-2500 Series Vibrometer Controllers OFV Series Sensor Heads CLV-2534 Compact Laser Vibrometer IVS-200 Industrial Vibration
More informationVibroFlex Compact Compactness meets versatility Preliminary datasheet. VibroFlex Compact
VibroFlex Compact The Polytec VibroFlex laser Doppler vibrometer is a modular high-performance solution for non-contact vibration mea sure ment. It offers unrivalled measurement performance and versatility
More informationPSV-400-3D Scanning Vibrometer
PSV-400-3D Scanning Vibrometer POLYTEC SCANNING VIBROMETERS PSV-400 Polytec Scanning Vibrometer PSV-400-3D Scanning Vibrometer MSV-400 Microscope Scanning Vibrometer PMA-400 Planar Motion Analyzer MMA-400
More informationbelow. AOTF Module / Optics R O B U ST. R E L I A B L E. A C C U R A T E AOTF Video Adapter (Series VA310) KEY FEATURES POTENTIAL APPLICATIONS
KEY FEATURES VIS-NIR-SWIR Range 400-1700 nm Low-Power Consumption High-Switching Speed: 16,000 λ/sec Real Time Image Display Solid State / No Moving Parts High-Spectral Resolution Immune to vibration No
More informationVibroFlex. VibroFlex Non-contact vibration measurement from nano to macro Product brochure
VibroFlex VibroFlex Non-contact vibration measurement from nano to macro Product brochure Precision is a choice Laser Doppler vibrometers from Polytec combine precise optical vibration measurement with
More informationCinCam CCD - Technical Data -
- Technical Data - SENSOR DATA CCD-1201 CCD-1301 CCD-2301 CCD-2302 Format: 1/2 1/3 2/3 2/3 Active area: 6.5mm x 4.8mm 4.8mm x 3.6mm 9.0mm x 6.7mm 8.5mm x 7.1mm Number of pixel: 1388 x 1038 (1.4MPixel)
More informationMore Precision. optoncdt // Laser displacement sensors (triangulation)
More Precision optoncdt // Laser displacement sensors (triangulation) 1 High Speed PSD Sensors optoncdt 1610 / 1630 INTER FACE Nine models with measuring ranges from mm to 100 mm Sensor head and separate
More informationLIFA KEY FEATURES APPLICATIONS. Fluorescence Lifetime Attachment LIFA 15001A02 16/03/2015
LIFA Fluorescence Lifetime Attachment LIFA 151A2 16/3/215 The LIFA is a dedicated system for Fluorescence Lifetime Imaging Microscopy (FLIM). It allows the generation of lifetime images on any widefield
More informationMore Precision. optoncdt // Laser displacement sensors (triangulation)
More Precision optoncdt // Laser displacement sensors (triangulation) 1 High Speed PSD Sensors optoncdt 1610 / 1630 INTER FACE Nine models with measuring ranges from mm to 100 mm Sensor head and separate
More informationMore Precision. thermoimager TIM // Compact thermal imaging cameras
More Precision thermoimager TIM // Compact thermal imaging cameras 10 Smallest VGA infrared camera in the world thermoimager TIM 640 thermoimager TIM 640 Miniature infrared camera with VGA resolutions
More informationTechnical Specifications for High speed PIV and High speed PIV-PLIF system
Technical Specifications for High speed PIV and High speed PIV-PLIF system MODULE A. HIGH SPEED PIV (3-C) A1. Double Cavity High Speed Laser (up to 10 khz): The vendor should provide Dual Head (DH) laser
More informationLIFA. SPECIFICATIONs. Fluorescence Lifetime Attachment LIFA14001A02 25/02/2014
LIFA Fluorescence Lifetime Attachment The LIFA is a dedicated system for Fluorescence Lifetime Imaging Microscopy (FLIM). It allows the generation of lifetime images on any widefield fluorescence microscope
More informationThe Anfatec Level AFM a short description. Atomic Force Microscopy - approved devices for affordable prices
The Anfatec Level AFM a short description Atomic Force Microscopy - approved devices for affordable prices Our system is complete for almost all typical applications. It provides all basic modes as: contact
More informationSpectraTec X. Multi- λ Laser Light Source BLUE SKY RESEARCH WAVELENGTHS
Multi- λ Laser Light Source BLUE SKY RESEARCH Up to four individual laser wavelengths One single mode PM fiber output Ultra-stable power output Compact : 165mm x 125mm x 34mm Integrated control and drive
More informationSample Sizes: up to 1 X1 X 1/4. Scanners: 50 X 50 X 17 microns and 15 X 15 X 7 microns
R-AFM100 For Nanotechnology Researchers Wanting to do routine scanning of nano-structures Instrument Innovators Using AFM as a platform to create a new instrument Educators Teaching students about AFM
More informationLaser profile sensor, laser scanner 2D/3D for beads and grooves
Laser profile sensor, laser scanner 2D/3D for beads and grooves Industrial laser profile sensor, 2D/3D laser scanner for fast CMOS profile measurement and laser line for beads and grooves, dimension, position
More informationAPPLICATIONS KEY FEATURES. High-speed intensified Camera Attachment
HiCATT High-speed intensified Camera Attachment The HiCATT is an intensified camera attachment specifically designed for use in combination with high-speed cameras. It can be used to amplify low light
More informationTABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE
TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CMOS TECHNICAL DATA SENSOR RESPONSE DIMENSIONS
More informationMore Precision. thermoimager TIM // Compact thermal imaging cameras
More Precision thermoimager TIM // Compact thermal imaging cameras 20 USB Server Gigabit / Process interface thermoimager TIM thermoimager TIM USB Server Gigabit Simple cable extension for the thermoimager
More informationNEW. Very high-speed profile measurement for industrial in line applications. 2D/3D profile sensor SENSORS & SYSTEMS
SENSORS & SYSTEMS SENSORS & SYSTEMS By far the better solution PRINCIPLE NEW 28 Very high-speed profile measurement for industrial in line applications. High accuracy and very high frame frequency thanks
More informationProduct Information Version 1.1. ZEISS Axiocam 503 mono Your Flexible and Sensitive 3 Megapixel Microscope Camera for Live Cell Imaging
Product Information Version 1.1 ZEISS Axiocam 503 mono Your Flexible and Sensitive 3 Megapixel Microscope Camera for Live Cell Imaging ZEISS Axiocam 503 mono Sensor Model Sensor Pixel Count Pixel Size
More informationLeica TCS STED. The Fast Track to Superresolution Technical Documentation
Leica TCS STED The Fast Track to Superresolution Technical Documentation 8 9 6 7 Inverted research microscope Leica DMI6000 CS Scan head Laser and power supply Computer table Air damped optical table 6
More informationNASA Miniature Inspection LADAR
NASA Miniature Inspection LADAR Bradley Sallee SPEC 1 SPEC s Multi-Dimensional Imaging Programs NASA HD6D NRO HD6D AFRL LGSS Army 3D Change AFRL MST Army Imaging SAL DARPA AIRSS DARPA SUAVTL NASA Inspection
More informationPOWERSIGHT LASER DOPPLER AND PHASE DOPPLER MEASUREMENT SYSTEMS
POWERSIGHT LASER DOPPLER AND PHASE DOPPLER MEASUREMENT SYSTEMS PROVIDING UNMATCHED FLEXIBILITY, SIMPLICITY, AND PATENTED TECHNOLOGY UNDERSTANDING, ACCELERATED THE POWERSIGHT LDV AND PDPA SYSTEMS AN INNOVATIVE
More informationPD910. 3MP bubbleless PTZ dome camera with 40x zoom
SIQURA PD910 3MP bubbleless PTZ dome camera with 40x zoom DESCRIPTION The PD910 is a 3-megapixel IP outdoor PTZ dome camera without a bubble. A powerful high-grade 40x optical zoom lens ensures sharp and
More informationProduct Information Version 1.0. ZEISS Axiocam 506 mono Your High Resolution Microscope Camera for Live Cell Imaging Fast, Flexible, and Sensitive
Product Information Version 1.0 ZEISS Axiocam 506 mono Your High Resolution Microscope Camera for Live Cell Imaging Fast, Flexible, and Sensitive ZEISS Axiocam 506 mono Sensor Model Sensor Pixel Count
More informationMore Precision. optoncdt // Laser displacement sensors (triangulation)
More Precision optoncdt // Laser displacement sensors (triangulation) 20 Sensor for shiny metallic and rough surfaces optoncdt 1750LL 312Hz 375Hz 1000Hz Analog Digital Filter inside Laser Line averages
More informationS-VIT LS High Speed Camera
S-VIT LS High Speed Camera Imaging for smart decisions PRODUCT LEAFLET TECHNICAL SPECS APPLICATION NOTE S-VIT LS the ruggedized, compact high speed camera for automotive safety testing and harsh industrial
More informationQuad-RO: 4320 X-RAY GROUP
Quad-RO: 432 284 x 284 imaging array 24 x 24 µm pixels The Princeton Instruments Quad-RO: 432 is a fully integrated, low noise, 4-port readout camera designed for indirect imaging of x-rays using phosphor
More informationLASERS FOR ANALYTICAL INSTRUMENTATION
LASERS FOR ANALYTICAL INSTRUMENTATION CW Lasers (Broad and Narrow Spectrum) Nanosecond SLM Lasers Accessories ADVANTAGES One size One control interface One voltage (+5 VDC) One software Many wavelengths
More informationMore Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)
More Precision scanontrol // 2D/3D laser scanner (laser profile sensors) scanontrol 27x gapontrol 27x1 Technical details and versions - z-axis up to 3mm - x-axis up to 148mm - Profile frequency up to 4,Hz
More informationWinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, * nm * model-dependent
Datasheet WinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, 190 1610* nm * model-dependent With an 11.3 x 11.3 mm active area, 4.2 Mpixels, 5.5 x 5.5 μm pixels, optical and electronic triggering
More informationSPECTRUM. The world s first fully automated Raman AFM. AFM - confocal Raman - SNOM - TERS AFM KPFM. Raman. AFM-Raman characterization of PS-PVAC
Raman KPFM AFM AFM-Raman characterization of PS-PVAC polymer blend film SPECTRUM The world s first fully automated Raman AFM AFM - confocal Raman - SNOM - TERS The first fully integrated & automated AFM
More informationTABLE OF CONTENTS PRODUCT DESCRIPTION LASERDEC CL200 / CL200HP TECHNICAL DATA DIMENSIONS LASERDEC CL500 / CL500HP TECHNICAL DATA DIMENSIONS
TABLE OF CONTENTS PRODUCT DESCRIPTION LASERDEC CL200 / CL200HP TECHNICAL DATA DIMENSIONS LASERDEC CL500 / CL500HP TECHNICAL DATA DIMENSIONS ACCESSORIES ATTENUATION UNIT 0 ATTENUATION UNIT 90 BEAM REDUCER
More informationDigital Microscope Inspection Systems
Vision for industry Digital Microscope Inspection Systems Omni FI 805-001 A 2D Measurement & Annotation Focus Stacking Image Overlay Comparator Lens Distortion Correction Calibration Tracking On Screen
More informationLatest Innovations Laser Power and Energy Measurement
Laser Power and Energy Measurement BF line of pyroelectric sensors Highest damage threshold coating 800mJ/cm2 for ns pulses Highest damage threshold diffuser 4J/cm2 IR to UV Widest spectral range with
More informationTechnical Specifications
Technical Specifications Version 2.48/2.49 2007-2008 Rev: January 2007 SQA-V Gold Technical Specifications The SQA-V is a high performance analytical medical device that combines state-ofthe-art technology
More informationCHAPTER 2: THREE DIMENSIONAL TOPOGRAPHICAL MAPPING SYSTEM. Target Object
CHAPTER 2: THREE DIMENSIONAL TOPOGRAPHICAL MAPPING SYSTEM 2.1 Theory and Construction Target Object Laser Projector CCD Camera Host Computer / Image Processor Figure 2.1 Block Diagram of 3D Areal Mapper
More informationVideo frame rates and higher to efficiently synchronize with high repetition rate lasers
PI-MAX3:1024 x 256 The PI-MAX3:1024 x 256 from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1024 x 256 spectroscopy CCD fiber-coupled
More informationTECHNICAL DATA OPTIV PERFORMANCE 443 DUAL Z
OPTIV PERFORMANCE 443 DUAL Z Product description The Optiv Performance 443 Dual Z combines optical and tactile measurement in one system. The system supports multi-sensor measurements using the Vision-Sensor,
More informationLASERS FOR ANALYTICAL INSTRUMENTATION
LASERS FOR ANALYTICAL INSTRUMENTATION CW Lasers (Broad and Narrow Spectrum) Nanosecond SLM Lasers Accessories ADVANTAGES One size One control interface One voltage (+5 VDC) One software Many wavelengths
More informationLaser Triangulation Displacement Sensors
Laser Triangulation Displacement Sensors 30 The high speed true analogue laser sensor optoncdt 1610 / 1630 16 models with measuring ranges from 0.5mm to 200mm Sensor head and separate controller Up to
More informationLASERS FOR ANALYTICAL INSTRUMENTATION
CW Lasers Combiners Q-switch Lasers >20 s MM/SM/PM fiber Single-frequency options 405 nm to 660 nm 4 wavelengths Open beam or Fiber 1029 nm / 514.5 nm High pulse energy Single Longitudinal Mode LASERS
More informationSLC ultra low jitter Clock Synthesizer 2 MHz to 7 GHz
SLC ultra low jitter Clock Synthesizer 2 MHz to 7 GHz Datasheet The SLC is a very affordable single or dual clock 7 GHz synthesizer that exhibits outstanding phase noise and jitter performance in a very
More informationSCALA. Scanning Laser Analyzer
SCALA Scanning Laser Analyzer SCALA TECHNOLOGY Mecwins offers an optical platform for MEMS characterization using its proprietary technology. SCALA is a complete tool to characterize your devices (cantilevers,
More informationThe Original Green LED Incorporated Digital Micrometer
The Original Green LED Incorporated Digital Micrometer [New Larger Diameter Head LS-7070(M)] [New Advance Controller LS-7601] [New PC Based Software LS-H1W] High-speed, High-accuracy Digital Micrometer
More informationOptimized Design of 3D Laser Triangulation Systems
The Scan Principle of 3D Laser Triangulation Triangulation Geometry Example of Setup Z Y X Target as seen from the Camera Sensor Image of Laser Line The Scan Principle of 3D Laser Triangulation Detektion
More informationhsfc pro 12bit ultra speed intensified imaging
hsfc pro 12bit ultra speed intensified imaging four MCP-image intensifier camera modules ultra fast shutter down to 3ns (optional 1.5ns) in single mode excellent sensitivity of the system allows single
More informationMore Precision. optoncdt // Laser displacement sensors (triangulation)
More Precision optoncdt // Laser displacement sensors (triangulation) 8 Compact laser triangulation displacement sensor optoncdt 1320 312Hz 375Hz 1000Hz Ideal for serial and OEM applications Compact design
More informationQ-VIT High Speed Camera
Q-VIT High Speed Camera Imaging for smart decisions PRODUCT LEAFLET TECHNICAL SPECS APPLICATION NOTE Q-VIT the ruggedized, compact high speed camera with an ultrahigh resolution of 3MPixel for automotive
More informationGenesis MX STM-Series
Genesis MX STM-Series TEM00 Visible OEM and End-User OPS Laser Systems Applications like Flow Cytometry, Particle Counting, DNA Sequencing and Microscopy are enable by low noise, visible true CW lasers.
More informationVISION MEASURING SYSTEMS
VISION MEASURING SYSTEMS Introducing Mitutoyo s full line of Vision Measuring Equipment. VISION MEASURING SYSTEMS Quick Scope Manual Vision Measuring System Manual XYZ measurement. 0.1 µm resolution glass
More informationevue Digital Imaging System DATA SHEET FEATURES / BENEFITS
evue Digital Imaging System DATA SHEET The evue digital imaging system is optimized for on-wafer test with Cascade Microtech s probe stations. The revolutionary multi-optical path, multi-camera design
More informationComplete Barrel Measuring and Inspection System. PS Series. User s manual
Complete Barrel Measuring and Inspection System PS Series User s manual SAFETY PRECAUTIONS... 3 ELECTROMAGNETIC COMPATIBILITY... 3 LASER SAFETY... 3 GENERAL INFORMATION... 3 BASIC DATA AND PERFORMANCE
More informationBMFL WashBeam W OSRAM Lok-it! HTI 1700/PS lm, m, m 5-45
BMFL WashBeam The strong-arm of the BMFL family - the superbly powerful BMFL WashBeam comes with extra bright output and an abundance of great features, e.g newly developed framing shutters, super wide
More informationCertus Standard. NanoScanTechnology. Basic Datasheet. reasoned innovations. Basic Configuration of Scanning Probe Microscope
NanoScanTechnology reasoned innovations Nano Scan Technology Ltd. Russia, 141700, Dolgoprudny, Zavodskaya St, 7 Phone: +7 (495) 642-40-68 +7 (495) 642-40-67 Skype: NanoScanTech E-mail: info@nanoscantech.ru
More informationMore Precision. optoncdt // Laser displacement sensors (triangulation)
More Precision optoncdt // Laser displacement sensors (triangulation) 10 Smart laser triangulation displacement sensor optoncdt 1420 312Hz 375Hz 1000Hz Ideal for serial and OEM applications Compact design
More informationCUBE. Diode Laser System. Superior Reliability & Performance
Features Compact and modular OEM design Complete CDRH safety features for scientific and laboratory use TEC temperature-stabilized and conductively cooled through baseplate Analog and digital modulation
More informationMirror positioning on your fingertip. Embedded controller means tiny size plus fast, easy integration. Low power for hand-held systems
SMALL, PRECISE, SMART IN MOTION DK-M3-RS-U-1M-20 Developer s Kit Single-Axis Mirror Positioning System Miniature piezo smart stage with built-in controller for simple, precise point-to-point positioning
More informationCLV Compact Laser Vibrometer
CLV Compact Laser Vibrometer High Performance Vibration Measurements For Industrial Needs Non-Contact Vibration Measurement Laser Doppler vibrometers (LDVs) are optical instruments employing laser technology
More informationTRiCAM APPLICATIONS KEY FEATURES. Time Resolved intensified CAMera. TRiCAM 13001A01 31/10/2013
TRiCAM Time Resolved intensified CAMera The TRiCAM is a compact Intensified CCD camera for scientific and industrial applications that require 1) lowlight level imaging, 2) ultra-short exposures through
More informationUV-NIR LASER BEAM PROFILER
- Technical Data - CCD-1201 CCD-2301 CCD-2302 Standard Series Standard Series Standard Series SENSOR DATA Format: 1/2 2/3 2/3 Active area (without cover glass): 6.5mm x 4.8mm 9.0mm x 6.7mm 8.5mm x 7.1mm
More informationP recise Eye. High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection.
High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection. Long working distance makes lighting and handling easier. Compact size. Coaxial lighting available
More informationDS-2CD6D24FWD-(I)Z(H)(S)(/NFC) EXIR Flexible PanoVu Network Camera
DS-2CD6D24FWD-(I)Z(H)(S)(/NFC) EXIR Flexible PanoVu Network Camera 1/2.7 Progressive Scan CMOS 1920 1080 @ 30fps FOV: horizontal 30 to 96.3, vertical 17 to 54, diagonal 34 to 121 H.265, H.264, H.265+,
More informationNEW! Smart Camera Series LSIS 400i Fast and simple quality assurance and identification through innovative and high-performance camera technology
2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 E-mail:hvssystem@hvssystem.com Site web : www.hvssystem.com Smart Camera Series LSIS 400i Fast and simple quality assurance
More informationCalibration of a portable interferometer for fiber optic connector endface measurements
Calibration of a portable interferometer for fiber optic connector endface measurements E. Lindmark Ph.D Light Source Reference Mirror Beamsplitter Camera Calibrated parameters Interferometer Interferometer
More informationMore precision. thermometer CTVideo/CSVideo // Infrared temperature sensors
More precision thermometer CTVideo/CSVideo // Infrared temperature sensors 2 Infrared temperature sensors with crosshair laser sighting and video module thermometer CTVideo/CSVideo - Parallel use of video
More informationPI-MAX 4: 1024 x 256 SPECTROSCOPY GROUP
Powered by LightField The PI-MAX4: 1024 x 256 from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1024 x 253 pixel spectroscopy
More information4. Recommended alignment procedure:
4. Recommended alignment procedure: 4.1 Introduction The described below procedure presents an example of alignment of beam shapers Shaper and Focal- Shaper (F- Shaper) with using the standard Shaper Mount
More informationHyperRapid NX SmartCleave
High-Speed and High-Quality Brittle Material Processing is an industrial high-power picosecond laser that is specifically optimized for high-speed and high-quality cutting of transparent and brittle materials.
More informationHDAF800 HD 1080p Digital Microscope USB drive for Image Capture
HDAF800 HD 1080p Digital Microscope USB drive for Image Capture HDAF800-US Auto-Focus HD Camera System 1080p including Universal Stand with 15" Vertical Pole and integrated LED lighting and controls panels.
More information6220 Ethernet-Based Voltage Measurement Module
Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100 khz per channel sample rate ±10 V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger modes
More informationPrizmatix. Optical Specifications. Mic-LED-635 spectrum. BLCC-02 Benchtop LED Current Controller Specifications
Mic-LED-635 High Power Collimated Red LED Light Source for Fluorescence Microscopy Featuring Prizmatix Modular Design for Multi-Wavelength and Fiberoptic Setup Ver. 01 Introduction The compact Mic-LED-635,
More informationRoHS COMPLIANT 2002/95/EC
Superlum Broadband Light Sources cblmd-series (2nd Generation) Compact Broadband Light Technical Product Specification Document Number SL.3328.00.000D3 June 2017 Revision 001 ATTENTION ELECTROSTATIC SENSITIVE
More informationMore Precision. optoncdt // Laser displacement sensors (triangulation)
More Precision optoncdt // Laser displacement sensors (triangulation) 12 Smart triangulation displacement sensor of laser class 1 optoncdt 1420 CL1 Ideal for serial and OEM applications Laser class 1 Compact
More informationMore Precision. optocontrol // Optical precision micrometers
More Precision optocontrol // Optical precision micrometers 12 Compact laser micrometer optocontrol 2520 Measuring range 46mm Target-sensor gap up to 2m Linearity
More informationCompatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.
PI-MAX 4: 1024f The PI-MAX4:1024f from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1k x 1k full-frame CCD fiberoptically coupled
More informationSpecifications PHAENON X Mini / Pro Laser Projectors
Released on 11/22/2017 1 High-end Full Color Laser Projectors for Professional Applications PHAENON X Mini PHAENON X Pro compact PHAENON X Pro (longish) Laser System Modular laser system based on unique
More informationFEATURES BENEFITS 1024 x 1024 Imaging Array High resolution imaging and spectroscopy
PI-MAX3:1024i The PI-MAX3:1024i from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1k x 1k interline CCD fiberoptically coupled
More informationLightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France
Lightsheet Z.1 Light Sheet Fluorescence Microscopy by Carl Zeiss Fabrice Schmitt, Sales Manager Carl ZEISS France 12.12.2012 Light Sheet Fluorescence Microscopy (LSFM) Principle The Principle of Light
More informationMore Precision. optocontrol // Optical precision micrometers
More Precision optocontrol // Optical precision micrometers 4 Compact laser micrometers with high measuring rate optocontrol 1200 / 1201 Measuring range 2-30mm Resolution 10µm Measuring rate up to 100kHz
More informationillumia plus Light Measurement Systems
illumia plus Light Measurement Systems Flexible, modular solutions with centralized data management FLEXIBILITY Introducing Labsphere illumia plus light measurement systems flexibility to meet your most
More informationMore Precision. optoncdt // Laser Triangulation Displacement Sensors
More Precision optoncdt // Laser Triangulation Displacement Sensors 20 Sensor with laserline for shiny metallic and rough surfaces optoncdt 1700LL 312Hz 375Hz 1000Hz Analog Digital Filter inside Laser
More informationProduct Information Version 1.1. ZEISS Axiocam 702 mono Your 2.3 Megapixel Microscope Camera for Fast Low Light and Live Cell Imaging
Product Information Version 1.1 ZEISS Axiocam 702 mono Your 2.3 Megapixel Microscope Camera for Fast Low Light and Live Cell Imaging ZEISS Axiocam 702 mono Sensor Model Sensor Pixel Count Pixel Size Sensor
More informationM-545 Manual XY Microscope Stage For Olympus, Nikon, Leica & Zeiss Microscopes / PI Piezo Stages
M-545 Manual XY Microscope Stage For Olympus, Nikon, Leica & Zeiss Microscopes / PI Piezo Stages M-545 manual microscopy stages are designed to accommodate the P-545 PInano series of XY / XYZ Piezo stag
More informationPrecise Eye High Mag Fixed Lenses
Precise Eye High Mag Fixed Lenses High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection. Long working distance makes illumination and handling easier.
More informationC x Hexapod Motion Controller
C-887.52x Hexapod Motion Controller Compact Bench-Top Device for Controlling 6-Axis Systems Sophisticated controller using vector algorithms Commanding in Cartesian coordinates Changes of the reference
More informationLeica TCS SPE. Spectacular Imaging! Technical Documentation
Leica TCS SPE Spectacular Imaging! Technical Documentation Leica TCS SPE Spectacular Imaging Easy to Achieve A Reliable System Affordable Excellence The high resolution spectral confocal Leica TCS SPE
More informationPSV-500 Scanning Vibrometer Full-fi eld vibration measurement Datasheet. PSV-500 Scanning Vibrometer
PSV-500 Vibrometer Polytec Vibrometers are state-of-the-art for noise and vibration measurement in research and development. They determine operational defl ection shapes and Eigenmodes for NVH, acoustics,
More informationMore Precision. optoncdt // Laser displacement sensors (triangulation)
More Precision optoncdt // Laser displacement sensors (triangulation) 10 Smart laser triangulation displacement sensor optoncdt 1420 312Hz 375Hz 1000Hz Ideal for serial and OEM applications Compact design
More informationBMFL Spot. Light source 1700 W OSRAM Lok-it! HTI 1700/PS. LIGHT OUTPUT lm, m, m.
BMFL Spot The BMFL Bright Multi- Functional Luminaire much anticipated new lighting fixture from Robe, brings a real game changer in the world of moving lights. The BMFL Spot has a custom light source
More informationMore Precision. optoncdt // Laser displacement sensors (triangulation)
More Precision optoncdt // Laser displacement sensors (triangulation) 30 lue Laser Triangulation Displacement Sensors optoncdt 10L 3Hz 3Hz 1000Hz nalog Digital Filter inside Six models with s from 20 mm
More informationSNC-RZ30N (NTSC) SNC-RZ30P (PAL)
PRELIMINARY NETWORK CAMERA SNC-RZ30N (NTSC) SNC-RZ30P (PAL) The Network Camera Experience - Anyone, Anytime, Anywhere Network cameras have been steadily making their way into the market over the past few
More informationDigitally Controlled Fast Shutter Camera
Digitally Controlled Fast Shutter Camera NANOCAM HF4 Applications High Speed Imaging Flame & Plasma Research Short Time Physics Fluorescence Microscopy UV measurement Vibration Analysis Astronomy Single
More informationSeBa Digital Imaging Systems
SeBa Series LAXCO, INC. SeBa Digital Imaging Systems SeBa 2 SeBa 3 SeBa Pro 4 SeBa Pro 4B SeBa Pro 5 9.7 full retina touchscreen display 5MP color camera User-friendly touchscreen interface Parfocal, parcentric,
More informationDatasheet 2102 SERIES TWO-AXIS POSITIONING AND RATE TABLE SYSTEM
Datasheet 2102 SERIES TWO-AXIS POSITIONING AND RATE TABLE SYSTEM FEATURES Position Accuracy: ± 30 arc seconds (both axes) Rate Accuracy: ± 0.01% Max Rate (varies depending on axis configuration): Inner
More informationRAMM Microscope Configuration Guide
RAMM Microscope Configuration Guide ASI s RAMM frame microscopes are modular open frame alternative to conventional commercial microscopes. Using a RAMM frame may be especially appropriate for instruments
More information