User Manual Revision 1.02

Size: px
Start display at page:

Download "User Manual Revision 1.02"

Transcription

1 User Manual Revision 1.02 Manufactured by

2 Contents 1. Introduction Disclaimer and Warranty Specifications Features Quick Start Guide Hardware Software Detailed Operating Instructions Fetch / Send Settings Events Configuring Events Selecting Events Board Info General Settings General Missed Call Control Arm / Disarm Control AC Detect Daily Test Report Admin Cell Numbers Gate Control Settings Inputs & Outputs Digital Inputs Analog Inputs Digital Outputs SMS Messages Admin SMS Commands Gate Control SMS Commands Logs Manage Settings Load Default Settings Copy/Paste Settings... 22

3 7. ioxpander Add-On Board Specifications Adding a ioxpander board to your profile mA Inputs... 24

4 1. Introduction Time is precious, why waste it? The GSM GENIE will save you time and add value to existing customer infrastructure! This jack-off-all-trades little gem will take care of all the little tasks you do daily. The GSM GENIE will open your gate, clean your pool, switch your geyser, manage your lights, water your plants, monitor your alarm, manage your generator or even make a noise itself when you re not home. Its uses extends way beyond your home, borehole pump or irrigation, this really is the master of automation. What about townhouse complex access control or making sure the grandparents are home. The possibilities are truly endless - the GENIE will simplify your life! 2. Disclaimer and Warranty Disclaimer: This product is designed to operate as a communication device, which will perform certain functions if triggered via SMS. It is also able to send an SMS as a result of certain actions. The product has been manufactured to the best standards and strictly in line with the design specifications, however the manufacturer, supplier and all other parties cannot guarantee it will function in one hundred percent of applications and circumstances. The system is reliant on third party service providers and Sabertek and its partners have no control over these third parties. For this reason we recommend that you do not use this device for critical services. Although we, and many customers have found it to be highly successful, please be aware that no party can guarantee its effectiveness. Under no circumstances should the GSM Genie be used in a medical application, life support or related service. Warranty: The product is guaranteed against defective workmanship for a period of twelve months from date of manufacture. As the manufacturer has no control over the use of the product we cannot guarantee damage caused by poor installation, errors, environmental influences and general misuse or abuse. If the instructions are followed the GSM Genie should give you many years of trouble free use.

5 3. Specifications Specification Dimensions (mm) 110x90x27 (WxHxD) Power Supply 9-32V DC via DC Jack Operating Current 60mA (no loads connected) Power Consumption < 2W Operating Temperature -10 to 65 o C (Battery charging will be suspended above 50 o C) Digital Inputs 0 12V (Isolated) Analog Inputs 0 30V Relay Outputs 3A / 125VAC, 30VDC AC Input 0 400VAC Lead Acid Battery 12V IO Connector Type Pluggable screw terminals 4. Features Digital Inputs 2 Analog Inputs 2 Digital Outputs 2 AC inputs 1 Lead Acid Battery YES Internal Battery YES SIM Card Slot 1 GPRS Capability YES RF Interface Coming soon!

6 5. Quick Start Guide 5.1 Hardware 1. Connect the antenna to the GSM port. 2. Insert a SIM card into the SIM card slot. Make sure the SIM PIN is either disabled or set to Connect the power supply to the unit. 4. The unit will sound with a double beep and the green heartbeat LED should start flashing. If not, make sure the power supply is plugged in and switched on. 5. The unit will now try to connect to the server for the first time. If successful, the heartbeat LED will start blinking with a double flash. It should not take longer than 5 minutes. Please Note: If the red GSM LED does not stop flashing after a short while, make sure the GSM antenna is connected and the SIM card in inserted correctly. This indicates that there is a problem with either the SIM card or GSM network.

7 5.2 Software 1. Download & save the latest version of software from Please note that you will not be able to use this software without an internet connection. 2. Start the software by double clicking on the EXE file downloaded in step (1). The login screen should be visible. 3. First time users will first have to register by clicking on the Register button.

8 4. Enter all your details and click on Register. The software will automatically return to the Login screen. Tick the Remember me checkbox if you want the software to save your username & password so that you do not need to enter it every time. 5. Click on Login button. You should now be logged into the software. 6. If the unit has made a successful connection as described in section 5.1, it can be added to your profile. Several GENIE s can be added to a single profile. 7. To add the GENIE to your profile, click the Add MainBoard button and enter the unit s serial number in the textbox. 8. Click the Add board button. The software will return to the main screen and the newly added board should now be visible under the MainBoards section.

9 9. To start configure the GSM GENIE, click on the appropriate board under the MainBoards section. 10. Please note: The GENIE will only connect every 3 hours to fetch new settings from the cloud server. This can be immediately requested by sending a SMS to the unit (refer to section 6.6) BUT your cellphone number must be in the Authorized Cell Numbers section under the General Settings tab. 11. When finished with configuring the unit, click the Send Settings button. This will upload all settings to the cloud server.

10 6. Detailed Operating Instructions 6.1 Fetch / Send Settings Fetching / sending of settings to and from the cloud server is done using these buttons. Please note: If any changes were made, the settings must be uploaded using the Send Settings button before it will take effect. 6.2 Events The GSM GENIE is an event based system where certain inputs can trigger events. Events can be anything from switching an output or sending a SMS message. The GSM GENIE cater for 64 different events Configuring Events Events are configured using the Manage Events button on the main screen. Event Name: Name of the event. It is advisable to give a descriptive name to each event because it will make it easier to recognize events when configuring inputs/outputs.

11 Event Type: Currently there are four event types namely OUTPUT, SMS, CALL, DSP OUTPUT Event This event will switch, pulse or toggle an output. The desired channel is selected via the dropdown which will automatically be populated with the available channel outputs. The pulse length & count is configured in the Digital Output settings of each channel (refer to section 6.5.3) SMS Event This event will send a SMS message to a specific cell phone number. The number and message can be entered in the available text boxes CALL Event This event will generate a missed call to a specific cell phone number. The number can be entered in the available text box DSP Event This event will display a message on a DSP Xpander board. The desired DSP board can be selected via the dropdown which will automatically be populated with the available DSP boards. The DSP board have 5 different modes which will be explained in section x.x.x Please note: This event will only be available if you have a DSP Xpander board connected to your GSM GENIE Selecting Events All configured events will show up in the list when selecting events for input & output channels. Multiple events can be selected and all events can be re-used on different channels.

12 6.3 Board Info This tab provide information regarding the status of the selected board. Board Type: Serial Number: Firmware Version: IMEI: IMSI: Cell Number: Signal Quality (CSQ): Last Seen: Updated: Board type Serial number of the unit Current firmware version of the unit International Mobile Equipment Identity (IMEI) of the unit s GSM modem International Mobile Subscriber Identity (IMSI) of the unit s SIM card Cellphone number of the unit s SIM card GSM signal quality of the unit. A value above 15 is preferred to ensure good communication between the unit and cloud server. The timestamp of the last connection between the unit and cloud server. Indicates if the unit has received its latest settings and is therefore synced with the cloud server.

13 6.4 General Settings General Nick Name: Daily SMS Limit: SMS Password: SIM Pin: This allow you to set a nick name for your device for identification purposes. The nick name will be used in the daily test report and in SMS messages. The maximum number of SMS messages the unit can send per day. This feature will limit the unit to a certain number of SMS messages when for example an input changes state frequently. The SMS password is used to authenticate the message for security purposes. This password is used to perform all SMS functions. The 4-digit pin code of the SIM card. Please note: If this pin code does not correspond to the pin code of the SIM card, you GSM GENIE will not be able to communicate Missed Call Control When enabled, the GSM GENIE will respond to missed calls from any authorized number (refer to section 6.4.6). When disabled, all missed calls will be ignored Arm / Disarm Control The GSM GENIE can be used as an burglar alarm system by arming and disarming the system. This setting will enable the arm/disarm functionality of the unit. When disabled, all inputs will be active.

14 When enabled and the system is disarmed, all inputs will be ignored. This is useful when there is for instance a PIR motion sensor connected to one of the inputs and you only want it to be active at certain times. When enabled and the system is armed, all inputs will be active. Arming and disarming is done via a SMS command (refer to section 6.4.3) AC Detect This is a dedicated input for AC mains to detect power outages. The trigger time (in minutes) is the time that needs to elapse before the unit will trigger the OFF/ON events Daily Test Report When enabled, the unit will send a daily SMS report to the Master Number (refer to section 6.4.6). This gives the user confirmation that the unit is in working order and have network coverage. The report time can be set in 24-hour format and the report will contain information like the firmware version, current time, GSM signal quality etc.

15 6.4.6 Admin Cell Numbers The GSM GENIE can be programmed with up to 10 admin cell phone numbers. These 10 numbers will be able to control the unit by SMS. Please note: Only the Master Number will receive the daily test report as described in section HINT: Always make sure that the Master Number is programmed.

16 6.4.7 Gate Control Settings Enable Temp Access: This will enable/disable a feature called temporary access. If enabled, all programmed cell numbers can allow any number to control selected events for a specific time. This feature is useful when the unit is installed on a gate motor at a complex or estate to allow visitor access. (Refer to section 6.6.2) Temp Access Validity: The time (hours) before a temporary cell number expires. Two Gate Setup: SMS Msg: If the complex or estate have separate gates for entry & exit this feature must be enabled. The SMS message that must be sent to execute the selected events. Gate Control Nrs can use Missed Call: If enabled, temporary cell numbers will be able to missed call the unit. (See section 6.4.2) Gate Control Cell Numbers The GSM GENIE can be programmed with up to 500 numbers. Please note: These numbers will be limited to gate control functionality only. Only admin numbers will be allowed to control the unit by SMS as described in section 6.6.

17 6.5 Inputs & Outputs Digital Inputs The digital inputs on the GSM GENIE is optically isolated to protect the unit against electrical spikes. Digital inputs can be used to connect anything from a switch to a PIR motion sensor for an alarm system. Channel Name: Trigger Time: Debounce Time: The name for the channel. When an input changes state, this is the time in milliseconds that have to elapse before the input will trigger any event. The trigger time will reset if the input change state during this time. This the time in milliseconds that have to elapse after a state change before the input will trigger again. Please Note: Each digital input have a LED indicator which will be ON when the input is ON.

18 6.5.2 Analog Inputs The analog inputs on the GSM GENIE is rated for 0-30V. Analog inputs can be used to connect anything from a temperature probe to a pressure sensor. Channel Name: Low (V): High (V): Trigger Time: Debounce Time: Log Interval: The name for the channel. The voltage level where the channel will trigger the LOW events The voltage level where the channel will trigger the HIGH events When an input changes state, this is the time in milliseconds that have to elapse before the input will trigger any event. The trigger time will reset if the input change state during this time. This the time in milliseconds that have to elapse after a state change before the input will trigger again. If enabled, the actual value of the analog input together with the time will be logged. The interval options shown in the picture below. Values can be exported by clicking on Show Log for analyses.

19 6.5.3 Digital Outputs The digital outputs on the GSM GENIE is rated at 3A / 125VAC, 30VDC. Digital outputs can be used to switch most types of electrical loads such as gate motors, lights and sirens. Each digital output have 3 terminal connections associated with them: COM - Common terminal N/C - Normally Closed terminal N/O - Normally Open terminal When the output is OFF, the COM and N/C terminals will be internally connected to each other. When the output is ON, the COM and N/O terminals will be internally connected to each other. Please Note: Each output have a LED indicator which will be ON when the output is ON. Channel Name: Pulse Length: Pulse Count: Default State: The name for the channel. The time in milliseconds that the output will change state when pulsed. The amount of pulses that will be generated if the output is triggered. The default state of the output. Schedule takes priority: If enabled and the output state is currently different than the default state because of the schedule, it will ignore any events generated by inputs. Remember State: If the GENIE reboots, it will remember the current state of the output and not follow the default state.

20 Schedule All outputs can be controlled by a weekly schedule which is selectable on an hourly basis. This is very useful to control a geyser, outside lights or swimming pool pump. To set a schedule for an output, click on the Set Schedule button. In the above example, the output will be ON from Monday to Friday from 06:00 until 18:00. On Saturday and Sunday s, the output will be ON from 08:00 until 16: SMS Messages Admin SMS Commands Only admin cell numbers will be allowed to use this functionality - Gate control numbers will not be allowed. SMS Format All SMS messages must be prefixed with the password chosen in section and type of message. After the password & type, the SMS instruction must follow. Please note: The instruction part of the message is not case sensitive.? = Query! = Command Password Type Instruction 1234! CONNECT SMS Command Description BEEP The unit will give a short beep on this command ARM The unit will enter the ARM state (Refer to section 6.4.3) DISARM The unit will enter the DISARM state (Refer to section 6.4.3)

21 RESET CONNECT 1X 2X The unit will reset The unit will immediately connect to the cloud server to fetch new settings Control output 1. Where X can be 0=OFF, 1=ON, 2=Pulse, 3=Toggle Control output 2. Where X can be 0=OFF, 1=ON, 2=Pulse, 3=Toggle SMS Query INFO STATUS ID BAL Description The unit will reply with a SMS containing it s nick name, firmware version, signal quality, 24 hour test time, current date and time, cell operator, IMSI and IMEI The unit will reply with a SMS containing it s armed status, digital output status, digital input status, analog input values and AC mains status The unit will reply with its serial number The unit will reply with its prepaid airtime balance. Please note: This will not work correctly with a contract SIM card or when roaming Gate Control SMS Commands This SMS messages do not need to be prefixed with the password. Please Note: Admin Numbers can also use this functionality. SMS Command Description TA x Allow temporary access to a cell number. Example: TA The unit will automatically send an SMS to the temporary number with instructions. Example: You have temporary access to [NICK NAME]. Please SMS [MSG] or phone this number to open the gate. Valid for a single entry & exit within 24 hours. [NICK NAME] = Nick name as programmed (refer to section 6.4.1) [MSG] = SMS message as programmed (refer to section 6.4.7) 6.7 Logs This shows the activity of the GSM GENIE. Input / output state changes will also be included in the log.

22 6.8 Manage Settings Load Default Settings To load a board s default settings, right click on the board under MainBoards and select Load Default Settings. Please note: Settings must first be uploaded to take effect. If you like to undo, please click on Download Settings without uploading the settings Copy/Paste Settings Settings can be copied between boards of the same type. To copy settings from one board to another, right click on Copy Settings, then right click on the new board and select Paste Settings

23 7. ioxpander Add-On Board The ioxpander is an add-on board which add extra inputs & outputs to the mainboard. Up to five of these boards could be connected to a single GSM Genie. 7.1 Specifications Dimensions (mm) 110x90x27 (WxHxD) Power Supply 9-32V DC via DC Jack Operating Current 60mA (no loads connected) Power Consumption < 2W Operating Temperature -10 to 65 o C Digital Inputs 4x (0 12V Isolated) 4-20ma Inputs 4x (0 30V) Relay Outputs 6x (3A / 125VAC, 30VDC) IO Connector Type Pluggable screw terminals Please note: This unit will not be able to operate without a GSM Genie mainboard.

24 7.2 Adding a ioxpander board to your profile 1. To add an ioxpander to a mainboard, right click on the mainboard under the MainBoards section. 2. Select Add IOX Board and enter the barcode number of the board. Please note: All changes to your current settings will be discarded if not uploaded. 3. If successful, the newly added IOX board will be visible under the Xpanders section. 4. Click on the board to open the configuration page on the left. 5. For Digital Input settings refer to section For Digital Output settings refer to section The 4-20mA inputs will be explained in the next section mA Inputs

25 The 4-20mA inputs on the ioxpander is rated for 4-20mA measurements. These inputs can be used for special sensors with high accuracy readings. Channel Name: Low: High: Sensor Min: Sensor Max: Log Interval: The name for the channel. The level where the channel will trigger the LOW events The level where the channel will trigger the HIGH events The sensors minimum reading this will normally be where the sensor outputs 4mA. The sensors maximum reading this will normally be where the sensor outputs 20mA. If enabled, the actual value of the analog input together with the time will be logged. The interval options shown in the picture below. Values can be exported by clicking on Show Log for analyses. Please note: For detailed configuration please refer to the sensors datasheet. For the latest info on new developed add-on boards, please visit

SMS Commander Manual

SMS Commander Manual SMS Commander Manual For the GB0101S V1.2 Before Attempting to connect or operate this product, please read these instructions in its entirety, especially the guarantee conditions. TABLE OF CONTENTS Introduction...3

More information

INDEX. Network Power Monitor R10 SNMP

INDEX. Network Power Monitor R10 SNMP Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX Amended 21 March 2017: Add user defined Password see page 13 Add wire Connection

More information

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above EZY SWITCH SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above Table of Contents Outputs 5 Inputs 6 COMMANDS Getting Started Setting Up Initial User 8 Adding a User 9

More information

Installation advice / help

Installation advice / help Installation advice / help Copyright Reserved : PicC Electronics (2014) 1. Do not connect the power of the SMS Alert to an auxiliary 12V power output. It is best to connect the SMS Alert directly to, and

More information

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor Innovative Electronics for a Changing World NPM-R10-SNMP Remote Network Power Monitor Optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM BATTERY CONNECTIONS 3. SERIES CONNECTED BATTERIES

More information

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION

More information

Copyright 2016 IPT PDUUM Revision

Copyright 2016 IPT PDUUM Revision PDUUM052016 Revision 1.03.250516 Table of Contents Introduction...3 Warranty...3 Installation...3 Operation...3 View...4 Adding PDU Servers...4 Agent Information...5 Graphs...5 Log Views...5 Tools...5

More information

DATA LOGGER (Version V1.3)

DATA LOGGER (Version V1.3) WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Operating instructions DATA LOGGER (Version

More information

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers MobilGate - 128d Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers MobilGate-128d is an industrial GSM module developed for remotely controlling doors, garage doors

More information

Mobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output

Mobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output Mobil Switch-Nano Industrial grade GSM signalling and remote control module with common input and relay output The MobilSwitch-Nano module is a general, industrial-grade GSM module, developed for remote

More information

ELC2212X user manual

ELC2212X user manual user manual 1 Safety: Please, keep safety precautions as follows: Do not use our device nearby the medical aparatures. Do not use our device nearby explosive atmosphere. Do not put to high moisture, chemicals

More information

GSM Communicator PSTN SIA DC-05 Protocol to SIA DC-09 Protocol & SMS Alert

GSM Communicator PSTN SIA DC-05 Protocol to SIA DC-09 Protocol & SMS Alert PSTN Alert To Wireless Alert! Compatible With Most Of The PSTN Security Control Panel. Special Designed For Your Existing PSTN Alarms Systems! PSTN SIA DC-05 Protocol to SIA DC-09 Protocol & SMS Alert

More information

Quick Start Guide. Data Logger TrueLog100

Quick Start Guide. Data Logger TrueLog100 Quick Start Guide Data Logger TrueLog100 Antenna Port 3 Port 4 1 1 1 1 Port 1 1 Port 2 RSSI PC Measure SIM + Battery + Solar Power Supply Figure 1: Top view of the data logger TrueLog100. All ports and

More information

Installation Guidelines for KODAK SA101 Alarm System

Installation Guidelines for KODAK SA101 Alarm System Installation Guidelines for KODAK SA101 Alarm System CONTENTS I- Installing the central unit Pages 3-4 II- Home page Page 5 III- Central unit set-up Page 6 IV- Installation and settings: Pages 7-13 cameras

More information

GSM communicator G16 USER MANUAL

GSM communicator G16 USER MANUAL USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS... 2 DESCRIPTION... 3 LIST OF COMPATIBLE CONTROL PANELS...

More information

GSM communicator GD-06 Allegro Complete manual

GSM communicator GD-06 Allegro Complete manual GSM communicator GD-06 Allegro Complete manual The GD-06 ALLEGRO is a universal GSM dialer and controller. It can be used for both home and industrial automation purposes, for security applications or

More information

EZY SWITCH. SMS-2 System Monitor Installation Manual

EZY SWITCH. SMS-2 System Monitor Installation Manual EZY SWITCH SMS-2 System Monitor Installation Manual Table of Contents System / Connections 4 Getting Started Setting Up Initial User 7 Adding a User 8 Removing a User 8 Adding an Administrator 8 Removing

More information

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel:

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: Energy Client Version 2.0.806 3. Feb. 2014 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: +45 88 80 75 80 www.electrocom.dk p. 2 Introduction... 3 Installation... 4 LED, Switches and Reset...

More information

QUICK GUIDE for 4 modules. Installation

QUICK GUIDE for 4 modules. Installation QUICK GUIDE for 4 modules Installation 1. Prepare a SIM card so that the PIN code is 1234 or is deactivated. Mount the card in the unit. The unit has now 1234 as password or runs without a password. The

More information

GPRS Pager 3 INSTALATION AND USER MANUAL

GPRS Pager 3 INSTALATION AND USER MANUAL GPRS Pager 3 INSTALATION AND USER MANUAL 1 Table of contents 1 Main functions of the GPRS Pager3...3 2 Operating mode, installation...3 2.1 Installation if no local network is available...3 2.2 Instalation

More information

MobilSwitch - Micro. 1. Operation: General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs

MobilSwitch - Micro. 1. Operation: General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs MobilSwitch - Micro General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs The MobilSwitch-Micro module is a general, industrial-grade GSM module, developed for

More information

Cellular Alert PRO PRODUCT MANUAL

Cellular Alert PRO PRODUCT MANUAL Cellular Alert PRO PRODUCT MANUAL Item # 3451, 3452, and 3453 Family of devices CONTENTS General Overview 3 Contents 3 Specifications 4 Important SIM Card Information 5 Setup 6 Sensor 8 Battery Setup 9

More information

QK-G031 Temperature GSM Remote Controller

QK-G031 Temperature GSM Remote Controller QK-G031 Temperature GSM Remote Controller Features Remote control from mobile phones Remote temperature monitoring and control Android APP interface Easy to install and configure (no PC required) Up to

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC

More information

SMS Transceiver V3 User manual

SMS Transceiver V3 User manual SMS Transceiver V3 User manual SMS Transceiver V3 - User manual ver. 1.8.3 - Fw: 3.0.7 - Sw: 1.6.2 Contents Page 1. Introduction 3 2. Connections 3 2.1 Inputs 3 2.2 Outputs 3 2.3 Power supply 3 2.4 Contacts

More information

Plus-X 300. Installation and Operation Manual

Plus-X 300. Installation and Operation Manual Plus-X 300 Installation and Operation Manual Table of Contents Introduction... 1 Compatibility... 1 Installation... 1 Configuration... 2 Operation... 5 Getting Help... 6 Warranty... 6 Appendix A: Specifications...

More information

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Contents 1 Warnings, Cautions, and Notes Description Features... 1 EnCell Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 1 3 Features... 1 3.1 STANDARD FEATURES... 1 3.2 FRONT PANEL FEATURES... 2 3.2.1 Display... 2 3.2.2 OK LED... 2 3.2.3 FAULT LED...

More information

M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016

M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016 M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016 00. CONTT INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. THE DEVICE DEVICE FUNCTIONS TECHNICAL CHARACTERISTICS VISUAL APPEARANCE 03. INSTALLATION

More information

page A.0240 Full_Product_catalogue_ BM.indb 110

page A.0240 Full_Product_catalogue_ BM.indb 110 page 110 0.07.A.0240 Full_Product_catalogue_23052016BM.indb 110 2016-10-25 02:38:03 PM GSM-BASED MONITORING AND CONTROL DEVICES GSM modules are the wave of the future when it comes to high-security yet

More information

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card. ENVIROMUX-AVDS-GSM(-P) GSM Automatic Voice Dialer INSTALLATION AND OPERATION MANUAL INTRODUCTION The ENVIROMUX-AVDS-GSM GSM Automatic Voice Dialer is used to send voice or text GSM or SMS alert messages

More information

PEGASUS DISTRIBUTOR S GUIDE

PEGASUS DISTRIBUTOR S GUIDE PEGASUS DISTRIBUTOR S GUIDE GPS /GPRS SOLUTION FOR YOUR FLEET Web Based Tracking System Tel: +44 (0)1509 808168 E- Mail: info@naxertech.com. www.naxertech.co.uk www.naxertech.com Revision History Note:

More information

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage: GSM communicator G10. (v.1.

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA   Webpage:   GSM communicator G10. (v.1. UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt GSM communicator G10 (v.1.xx) USER MANUAL Description The communicator G10 is designed to transmit

More information

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module ARDUINO BASED GSM/SMS Remote Control Unit USING SIM800 GSM Module Designed by ERIC BROUWER April 2017 Contents Introduction... 4 SIM Card requirements... 5 SIM Card Installation... 5 Electrical Connections...

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

CONTROL ANYTHING WITH YOUR CELLPHONE. Use your cellphone to remotely monitor and control the following applications with the CELLSWITCH 100

CONTROL ANYTHING WITH YOUR CELLPHONE. Use your cellphone to remotely monitor and control the following applications with the CELLSWITCH 100 CELLSWITCH 100 CONTROL ANYTHING WITH YOUR CELLPHONE Use your cellphone to remotely monitor and control the following applications with the CELLSWITCH 100 Security: Electric Fence / Power-failure / Fire

More information

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

Pitstop Fuel Timer. Operating Manual

Pitstop Fuel Timer. Operating Manual Pitstop Fuel Timer Operating Manual Doug Shelby Engineering Revised: 8/25/2013 Table Of Contents 1. System Description:... 2 2. Software Installation:... 2 3. Hardware Installation:... 2 4. Driver Installation:...

More information

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module ARDUINO BASED GSM/SMS Remote Control Unit USING SIM800 GSM Module Designed by ERIC BROUWER April 2017 Contents Introduction... 4 SIM Card requirements... 5 SIM Card Installation... 5 Electrical Connections...

More information

Tu Sitio de Automatización!

Tu Sitio de Automatización! 1. Overview a. Introduction Tu Sitio de Automatización! LBSMS Basic-Q421 is integrated with a 16 bit MCU and reliable Siemens MC39i GSM module. b. Application Industrial equipment monitoring Data capturing

More information

SMS ALERT 15 User Manual

SMS ALERT 15 User Manual For technical support, contact: 011 202 5884 or 083 235 4916. SMS ALERT 15 User Manual Features: - 15 non-user renamable inputs (input names must be specified on order). Alternative methods can be discussed

More information

SOFTWARE VERSION 3.3. CD P/N Rev. C

SOFTWARE VERSION 3.3. CD P/N Rev. C SOFTWARE VERSION 3.3 CD P/N 7301538 Rev. C 2 4 Introduction 1 4 General Specification: 1.1 4 Factory defaults parameters: 1.2 5 Basic Functionality 1.3 5 Password Protection 1.4 6 Operation 1.5 6 SMS support

More information

GSM CODELOCK ACCESS CONTROL UNIT

GSM CODELOCK ACCESS CONTROL UNIT GSM CODELOCK ACCESS CONTROL UNIT EIS ENTRY-LOCK Programming Software v.1.4.20160816 Contents 1 FOR YOUR SAFETY...3 2 INTRODUCTION...4 3 EIS ENTRY-LOCK FEATURES AND APPLICATIONS...5 4 START UP...6 5 LED

More information

1 Introduction Required components Datalogger TrueLog Baseboard... 1

1 Introduction Required components Datalogger TrueLog Baseboard... 1 - 1 Contents 1 Introduction... 1 2 Required components... 1 2.1 Datalogger TrueLog100... 1 2.1.1 Baseboard... 1 2.1.2 Battery holder with 2 pole power plug... 1 2.2 USB cable for logger configuration...

More information

MetriNet Cell Modem Manual

MetriNet Cell Modem Manual MetriNet Cell Modem Manual Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New Road, Delph Saddleworth

More information

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart. DICKSON GETTING STARTED 7-day chart rotation 0 to 100 o F KT8P0/2/3 & KT856 Remote Sensing Temperature Recorder QUICK START 1. Remove the protective pen cap(s). 2. Connect Probe(s): a. KT8P0/2/3: Make

More information

Communi-Cell Communicator Nokia Version

Communi-Cell Communicator Nokia Version Communi-Cell Communicator Nokia Version Jan 2007 Instruction Manual 1 ABOUT THE COMMUNI-CELL COMMUNICATOR SYSTEM The Communi-Cell Communicator system is based on GSM SMS technology. It uses a standard

More information

GS828. GPRS Data Logger

GS828. GPRS Data Logger Sirius Corp GPRS Data Logger Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors

More information

5.1 Configure each Sensor Pin Rename Set Rules Export Data Switching Nodes... 25

5.1 Configure each Sensor Pin Rename Set Rules Export Data Switching Nodes... 25 Hi-Gate User Manual Hi-Gate User Manual Hi-Gate User Manual Contents 1 Introduction... 3 1.1 Hi-Gate... 3 1.1.1 What is Hi-Gate... 3 1.1.2 Specifications... 3 1.1.3 Features... 4 1.2 Hi-Node... 5 1.2.1

More information

Cellcop Communicator CP72u-M

Cellcop Communicator CP72u-M Cellcop Communicator CP72u-M Feb 2015 User Manual ABOUT THE CELLCOP COMMUNICATOR SYSTEM The Cellcop GSM communicator system is based on SMS and GPRS technology. It uses standard cellphone technology for

More information

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel: FSK TX CELLULAR PLUS Installation and Programming Guide Tel: 0861 105 962 www.fsk.co.za INTRODUCTION The FSK TX Cellular Plus (TXC+) is a highly featured GSM based unit which is used for the transmission

More information

Automatic Phone-Out Home Monitoring System

Automatic Phone-Out Home Monitoring System Automatic Phone-Out Home Monitoring System Freeze Alarm Model Number: THP217 Product Description This product is intended to monitor homes, cabins, and other premises for low temperature conditions. It

More information

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage: GSM communicator G16T USER MANUAL

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA   Webpage:  GSM communicator G16T USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt GSM communicator G16T USER MANUAL Contents SAFETY REQUIREMENTS... 2 1 DESCRIPTION... 3 SPECIFICATIONS...

More information

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G User manual Martem AS 2014 CONTENTS 1. Description...3 2. Features...3 3. Interfaces...3 4. Indication and switches...4 4.1 State LED indication...4

More information

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software : DOOR ENTRY UNIT EIS-LCD Programming Software v.2.0 2018 Page 1 Contents 1 FOR YOUR SAFETY...5 2 INTRODUCTION...6 3 EIS-LCD, EIS-40 FEATURES AND APPLICATIONS...7 4 START UP...8 5 LED INDICATION...9 6

More information

WIRING DIAGRAMS NVIROMON NDCNTRLRS485. Remote Environmental Monitoring and Control for IT equipment. NVIROMON

WIRING DIAGRAMS NVIROMON NDCNTRLRS485. Remote Environmental Monitoring and Control for IT equipment. NVIROMON WIRING DIAGRAMS NVIROMON Remote Environmental Monitoring and Control for IT equipment. NVIROMON NDCNTRLRS485 Installation and wiring of NVIROMON system Items Quantity Equipment 1 NVIROMON unit 2 Temperature

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

: DOOR ENTRY UNIT. Programming Software USER MANUAL

: DOOR ENTRY UNIT. Programming Software USER MANUAL : DOOR ENTRY UNIT Programming Software MODELS: EIS-1, EIS-2 OR EIS-4 v.02 2018 Contents 1 FOR YOUR SAFETY...4 2 INTRODUCTION...5 3 EIS-1, EIS-2, EIS-4 FEATURES AND APPLICATIONS...6 4 START UP...7 5 LED

More information

A1000 GSM ALARM DEVICE

A1000 GSM ALARM DEVICE A1000 GSM ALARM DEVICE USER MANUAL A1000-REV2.1-1604 FW-A1000v2.93 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for installation,

More information

ProCon GSM INSTALLATION AND APPLICATION MANUAL. ProCon GSM manual. .gsm-komunikatorji.com. for module version 1.4

ProCon GSM INSTALLATION AND APPLICATION MANUAL. ProCon GSM manual. .gsm-komunikatorji.com. for module version 1.4 informacije in naročila: info@gsm-komunikatorji.com.gsm-komunikatorji.com ProCon GSM INSTALLATION AND APPLICATION MANUAL for module version 1.4 1 Index I. Basic descriptions... 3 II. Steps of installation...

More information

GSM controller module for SMS remote monitoring, alarming and control applications BR900-ST. Preliminary data. GSM module BR900-ST.

GSM controller module for SMS remote monitoring, alarming and control applications BR900-ST. Preliminary data. GSM module BR900-ST. GSM controller module for SMS remote monitoring, alarming and control applications BR900ST Preliminary data Introduction The BR900ST controller is a low dimensions low cost GSM communications device that

More information

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20 SS-10 3G FIXED CELLULAR TERMINAL USER MANUAL DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20 Revision History: Revision 01 Original document 12 August 2010 CONTENTS 1 INTRODUCTION...3 2 FEATURES...4 2.1 PHYSICAL

More information

GS828-H. GPRS Data Logger

GS828-H. GPRS Data Logger GPRS Data Logger GS828-H Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors via

More information

Boomerang System Administrator Manual

Boomerang System Administrator Manual Boomerang System Administrator Manual SG001-0003-01-B2.doc Page 1 of 43 Table of Contents INTRODUCTION...4 BOOMERANG CLIENT...5 FILE...6 3.1. Logout...... 6 3.2. Exit... 6 VIEW...7 4.1. Sensors events

More information

ComTroll 120 GLM GSM modem for sending SMS alarms from LineTroll fault Indicators

ComTroll 120 GLM GSM modem for sending SMS alarms from LineTroll fault Indicators ComTroll 120 GLM GSM modem for sending SMS alarms from LineTroll fault Indicators User Manual For software versions from 2.22 and newer Page 1 This document describes the COMTROLL 120 GSM Communication

More information

GSM Controller BR160SM-Sd BR161SM-Sd V1.2

GSM Controller BR160SM-Sd BR161SM-Sd V1.2 GSM Controller BR0SM-Sd BRSM-Sd V. Standard version for digital signal monitoring GSM module for SMS remote monitoring and control applications Alarm Notification Remote Control www.bieneelectronics.com

More information

TrackingTheWorld Global Asset Tracker (GAT)

TrackingTheWorld Global Asset Tracker (GAT) TrackingTheWorld Global Asset Tracker (GAT) Personal Tracker (WGAT) V1.15 Manual Index 1. Basic first startup and testing Page 3-8 Important before you start Page 4-5 Check before starting Page 6-8 2.

More information

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel Monitoring Converter GPRS-T1 Program version 1.01 gprs-t1_en 04/09 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl WARNINGS The module should only

More information

and/or b. an optional internal Iridium satellite modem.

and/or b. an optional internal Iridium satellite modem. Appendix D Manual for Data Logger/Control Unit D.1. Introduction and Specifications D.1.1. Q DL 2100 Data logger Platform The Q DL 2100 data logger platform consists of: 1. A microcontroller containing

More information

ZD-VT1 User Guide. ZENDA GPS Tracker ZD-VT1 User Guide

ZD-VT1 User Guide. ZENDA GPS Tracker ZD-VT1 User Guide ZENDA GPS Tracker ZD-VT1 User Guide Change History File Name ZD-VT1 User Guide Created By Kyle Lv Product ZD-VT1 Creation Date 2016-01-08 Update Date 2016-02-02 Subproject User Guide Total Pages 16 Version

More information

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS MANUFACTURER REQUIREMENTS The Manufacturer of the equipment and provider of related services shall provide

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

GSM communicator G17F INSTALLATION MANUAL

GSM communicator G17F INSTALLATION MANUAL INSTALLATION MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS...3 DESCRIPTION...4 SPECIFICATIONS...4 COMMUNICATOR

More information

GSM SECURITY AND CONTROL SYSTEM ESIM021

GSM SECURITY AND CONTROL SYSTEM ESIM021 GSM SECURITY AND CONTROL SYSTEM ESIM021 Manual v1.1 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: Alarm and control system

More information

AV-4000 GSM AV-4000 DVR

AV-4000 GSM AV-4000 DVR E a s y L o a d e r AV-4000 GSM AV-4000 DVR (for LED keypads) Integrated Alarm Control panel & Communicator Series 4000 Appendix for GSM Alarm Panels Version 1.05 Edition I This product is subject to continuous

More information

This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed.

This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed. This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed. The OCIO GSM system Transmit tank levels, via SMS and e-mail, on request.

More information

Installation and User Guide. Version 1.1

Installation and User Guide. Version 1.1 Installation and User Guide Version 1.1 Information in this document is subject to change without notice. Copyright 2016 - Crucible Technologies. All rights reserved. Crucible Technologies is a trading

More information

PRODUCT RANGE. Cellswitch Infinity GSM Intercom Complex GSM Intercom Index GSM Intercom Mini GSM Intercom 2Button

PRODUCT RANGE. Cellswitch Infinity GSM Intercom Complex GSM Intercom Index GSM Intercom Mini GSM Intercom 2Button PRODUCT RANGE Cellswitch Infinity GSM Intercom Complex GSM Intercom Index GSM Intercom Mini GSM Intercom 2Button CELLSWITCH Infinity 1 year free airtime, data, sms es and activated Vodacom and MTN simcards

More information

Plus-X 600. Installation and Operation Manual

Plus-X 600. Installation and Operation Manual Plus-X 600 Installation and Operation Manual Table of Contents Introduction... 1 Compatibility... 1 Unpacking... 1 Front Panel Indicators... 2 Hardware Configuration... 2 Installation... 4 Software Configuration...

More information

SEL-003. Manual. Wireless GSM alarm with ultra low consumption. No power supply needed!

SEL-003. Manual. Wireless GSM alarm with ultra low consumption. No power supply needed! SEL-003 Manual Wireless GSM alarm with ultra low consumption No power supply needed! Table of contents Introduction... 2 Central unit connectors... 3 SEL-003 connections... 4 Supply... 6 SIM card instalation...

More information

User Manual Revision English

User Manual Revision English Document code: MN67302_ENG Revision 1.100 Page 1 of 35 User Manual Revision 1.100 English GSM I/O and Alarms Modem for Website information: www.adfweb.com?product=hd67302 for Price information: www.adfweb.com?price=hd67302-b2-02

More information

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1 A1400 GSM Temperature Alarm USER MANUAL A1400-REV2.1-1604 FW-A1400v2.94 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for

More information

Model SFS01-V2 IMPORTANT! MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH

Model SFS01-V2 IMPORTANT! MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH Model SFS01-V2 DESCRIPTION The Model SFS01-V2 is a Multi-attempt Automatic Engine Smart Switch designed to automatically [remotely] or manually start and stop

More information

GSM WATER PUMP CONTROLLER AND MONITORING SYSTEM Model: GSM-0308WPC

GSM WATER PUMP CONTROLLER AND MONITORING SYSTEM Model: GSM-0308WPC GSM WATER PUMP CONTROLLER AND MONITORING SYSTEM Model: GSM-0308WPC Table of Contents Application..... 3 Instructions. 4 Installation Diagram....5 Device Design... 5 Technical Parameter....6 Setup Instruction.6

More information

rev mobile device to remotly control your home 2010 Cybrotech Ltd

rev mobile device to remotly control your home 2010 Cybrotech Ltd GSM-SA User Manual rev. 1.02 mobile device to remotly control your home 2010 Cybrotech Ltd Index Index...1 Description...2 Commands...3 Read inputs by message...3 Activate relay by message...3 Activate

More information

NX21 USER MANUAL. Telemetry Unit. Version 1.5

NX21 USER MANUAL. Telemetry Unit. Version 1.5 USER MANUAL Version 1.5 Nortech Management Ltd, United Kingdom NOV 2016 www.nortechonline.co.uk Doc Ref D_000344 Publication Notice Copyright Nortech Management Limited (NML). All rights reserved. No part

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

QUICK MANUAL for multiguard Master IO. Mounting

QUICK MANUAL for multiguard Master IO. Mounting QUICK MANUAL for multiguard Master IO Mounting 1. Prepare a SIM card so that the PIN code is 1234 or deactivated. Mount the card in the unit. The unit now has 1234 as password or runs without a password.

More information

JVA SMS Gateway User Manual

JVA SMS Gateway User Manual www.jva-fence.com.au JVA SMS Gateway User Manual PTE0319 JVA SMS Gateway User Manual Introduction The PTE0319 JVA SMS Gateway enables a group of JVA Z Series energisers to be controlled and monitored by

More information

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1 BrewTroller Phoenix Owners Manual Updated - March 14, 2016 BREWTROLLER PHOENIX 1 2016 BrewTroller All Rights Reserved. Product warranty or service will not be extended if: (1) the product is repaired,

More information

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs MobilTherm 2ad GSM temperature alarm module with auxiliay inputs and relay outputs The MobilTherm-2ad is a GSM temperature and remote signaling module, designed for GSM based remote control, remote signal.

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

WT-1010C2 GSM ALARM SYSTEM

WT-1010C2 GSM ALARM SYSTEM WT-1010C2 GSM ALARM SYSTEM User Manual WWII TTUU RR AA CC OORR PP OO RR AA TT IIOO NN SS DD NN BB HH DD Contents 1. Getting Started 4 1.1 In the Packaging....4 1.2 Viewing the WT-1010C2..4 2. Introduction

More information

GSM GENERATOR OUTPUT MONITORING ALARM SYSTEM (Three Phase) Model: GSM-0308G3P

GSM GENERATOR OUTPUT MONITORING ALARM SYSTEM (Three Phase) Model: GSM-0308G3P GSM GENERATOR OUTPUT MONITORING ALARM SYSTEM (Three Phase) Model: GSM-0308G3P Table of Contents Application.... 3 Instructions. 3 Installation Diagram....4 Device Design... 4 Technical Parameter....5 Setup

More information

ALL-IN-ONE, SENSORS-TO-CLOUD CELLULAR GATEWAY. User Manual. Stevens Part # A2 (4G LTE) Stevens Part # B2 (Verizon) Manual Version 1.

ALL-IN-ONE, SENSORS-TO-CLOUD CELLULAR GATEWAY. User Manual. Stevens Part # A2 (4G LTE) Stevens Part # B2 (Verizon) Manual Version 1. ALL-IN-ONE, SENSORS-TO-CLOUD CELLULAR GATEWAY User Manual Stevens Part #80060-70A2 (4G LTE) Stevens Part #80060-70B2 (Verizon) Manual Version 1.2 Contents 1. PRODUCT OVERVIEW... 3 2. SPECIFICATIONS...

More information

Guide Specification for 3G Wireless Battery Monitoring System

Guide Specification for 3G Wireless Battery Monitoring System Guide Specification for 3G Wireless Battery Monitoring System 3/11A FirstLine Wireless BMS 1 1.0 Scope This specification defines the minimum requirements for a predictive FirstLine Wireless Battery Monitoring

More information

FIFOTRACK PARAMETER TOOL USER GUIDE V1.1

FIFOTRACK PARAMETER TOOL USER GUIDE V1.1 FIFOTRACK PARAMETER TOOL USER GUIDE V1.1 Copyright 2015 fifotrack All rights reserved 1 Copyright and Disclaimer: All copyrights belong to Shenzhen fifotrack Solution Co., Ltd. You are not allowed to revise,

More information

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages GSM ProCom Description GSM and PSTN communication Management of 2 independent SIM cards Reception of incoming calls, possibility for restriction Installable behind PBX Management of different prefix numbers

More information

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... P.2 2. STANDARD AND OPTIONAL PARTS LIST..... P.2 3. FEATURE DEFINITIONS... P.3 4. TERMINAL DRAWING AND SPECIAL

More information

CCTR-820 Mini Water-proof GPS Tracker Using Guide

CCTR-820 Mini Water-proof GPS Tracker Using Guide CCTR-820 Mini Water-proof GPS Tracker Using Guide Welcome to use this Real Time mini water-proof GPS tracker CCTR-820, This product is with GPS module and GSM module, It is specially design for motor,

More information

InTimeGo-630 GPS Watch Tracker User Manual

InTimeGo-630 GPS Watch Tracker User Manual InTimeGo-630 GPS Watch Tracker User Manual Product: CCTR-630 Watch 1 set, Mini USB Charging Wire, Manual (CD or Print), AC Charger (Optional), Water-proof Bag for Pets Belt(Optional). Charging ON/OFF SOS

More information