CNI 508N1 ASSEMBLY COUPLING/DECOUPLING ASSEMBLY FOR UNSHIELDED AND SHIELDED HIGH-SPEED COMMUNICATION LINES UP TO 1GBIT/S
|
|
- Emerald Day
- 6 years ago
- Views:
Transcription
1 CNI 508N1 ASSEMBLY COUPLING/DECOUPLING ASSEMBLY FOR UNSHIELDED AND SHIELDED HIGH-SPEED COMMUNICATION LINES UP TO 1GBIT/S FOR TESTS ACCORDING TO... > EN > EN > EN > EN > EN > IEC > IEC > IEC CNI 508N1 - COUPLING/DECOUPLING ASSEMBLY FOR UNSHIELDED AND SHIELDED HIGH-SPEED COMMUNICATION LINES The EM TEST CNI 508N1 assembly is the first coupling/decoupling network available on the market to couple Surge onto unshielded and shielded high-speed communication lines with data rates up to 1,000MBit/s. The CNI 508N1 assembly consists of a coupling network CN 508N1, a decoupling network CNI 508N1 and a protection equipment SPN 508N1 to limit the residual voltage at the AE side. Additionally, the CNI 508N1 can be used as a coupling/decoupling network to apply Surge as well as Ringwave and Burst pulses to shielded lines. HIGHLIGHTS APPLICATION AREAS > Coupling to unshielded and shielded lines with up to 4 pairs TELECOM > Surge test voltage up to 4kV (1.2/50us) INDUSTRY > Data transfer up to 1,000MBit/s > max. 20V at 2kV > Ringwave test voltage up to 4kV (0.5us/100kHz) > Burst test voltage up to 4kV (5/50ns) RESIDENTIAL MILITARY EM TEST > PAGE 1/6
2 CN 508N1 - COUPLING NETWORK CNI 508N1 - COUPLING/DECOUPLING NETWORK COUPLING NETWORK FOR UNSHIELDED HIGH-SPEED COMMUNICATION LINES CDN FOR UNDSHIELDED AND SHIELDED HIGH-SPEED COMMUNICATION LINES The CN 508N1 is the coupling device including the matching resistors and the coupling devices to couple the 1.2/50us surge pulse up to 4kV on to max. 8 high-speed communication lines. The CN 508N1 also supports PoE and PoE+ standard requirements as per IEEE 802.3af-2003 and IEEE 802.3at The CNI 508N1 is a specifically designed CDN for testing high-speed communication lines. Its unique design allows data rates of up to 1,000MBit/s to be transmitted without degradation by the coupling/decoupling network. The decoupling network protects the auxiliary equipment limiting the residual voltage to max. 20V@2kV for common-mode surge test pulses. Moreover, the CNI 508N1 fully supports PoE and PoE+ standard requirements as per IEEE The CNI 508N1 may also be used for testing shielded cables as per IEC/EN , Fig. 16. It simplifies the test set-up and offers proper decoupling of the auxiliary equipment as well as a high safety for the operator as the surge is coupled through the CNI 508N1 rather than being directly applied to the metallic case of the DUT. Additionally, the CNI 508N1 may also be used to couple Ringwave pulse (0.5us/100kHz) and burst pulses to shielded cables. SPN 508N1 - SURGE PROTECTION NETWORK SURGE PROTECTION NETWORK FOR UNSHIELDED AND SHIELDED HIGH-SPEED COMMUNICATION LINES The SPN 508N1 is required to appropriately decouple the surge pulses from the auxiliary equipment. Its specific design allows the full data transfer up to 1GBit/s without causing signal degradation. The residual voltage at the AE port is limited to max. 10V@2kV surge voltage. EM TEST > PAGE 2/6
3 TESTING HIGH-SPEED COMMUNICATION LINES TEST SET-UP RECOMMENDATION FOR UNSHIELDED HIGH-SPEED COMMUNICATION LINES Coupling of the surge pulses is achieved by means of the CN 508N1 coupling network while the CNI 508N1 acts as the decoupling unit. For additional protection of the auxiliary equipment by reducing the residual voltage level the SPN 508N1 is used. MEETING POE AND POE+ REQUIREMENTS TEST SET-UP RECOMMENDATIONS FOR POE AND POE+ Using the SPN 508N1 Surge Protection Network to decouple the surge pulses from the auxiliary equipment directly influences the capabilities of the CN 508N1 and the CNI 508N1 to comply with the PoE and the PoE+ requirements. It is therefore recommended to install the PoE supply between the SPN 508N1 and the CNI 508N1 for proper operation of the PoE system. EM TEST > PAGE 3/6
4 CNI 508N1 - COUPLING/DECOUPLING NETWORK FOR SHIELDED LINES SURGE TEST MODE shielded cable with up to 4 pairs Max. 4kV* (1.2/50us) Max. Surge GENERAL DATA Dimensions 250mm x 110mm x 140mm (LxWxH) Weight approx. 10kg Temperature 5 C - 40 C (operation) Rel. humidity 10% - 90%, non condensing RINGWAVE TEST MODE shielded cable with up to 4 pairs Max. 4kV* (0.5us/100kHz) Max. Ringwave BURST TEST MODE shielded cable with up to 4 pairs Max. 4kV* (5/50ns) Max. Burst INPUTS Surge/Ringwave SHV connector Burst SHV connector TELECOM LINE SPECIFICATIONS Input/Output RJ45 female connectors for telecom lines Terminal layout Pair 1: pins 1/2 Pair 2: pins 3/6 Pair 3: pins 4/5 Pair 4: pins 7/8 Data rate up to 1,000MBit/s Operating voltage max. 100VDC Operating current max. 1A EM TEST > PAGE 4/6
5 CN 508N1 - COUPLING NETWORK FOR UNSHIELDED LINES SPN 508N1 - SURGE PROTECTION NETWORK FOR UNSHIELDED AND SHIELDED LINES SURGE TEST MODE 4 unshielded twisted pairs SURGE TEST MODE Max. 4kV* (1.2/50us) Number of lines 4 twisted pairs Max. discharge current 2kA (8/20us) without destruction to the RJ45 contacts max. 10V Insertion loss < -1.5dB (300kHz - 100MHz) Coupling device 90V gas arrestor Matching resistor 8 x 250ohm/line TELECOM LINE SPECIFICATION INPUTS Surge SHV connector TELECOM LINE SPECIFICATION Input/Output RJ45 female connector for telecom lines Terminal layout Pair 1: pins 1/2 Pair 2: pins 3/6 Pair 3: pins 4/5 Pair 4: pins 7/8 Data rate up to 1,000MBit/s Operating voltage max. 50VDC Operating current max. 1A Input/Output RJ45 female connectors for telecom lines Terminal layout Pair 1: pins 1/2 Pair 2: pins 3/6 Pair 3: pins 4/5 Pair 4: pins 7/8 Data rate up to 1,000MBit/s GENERAL DATA Dimensions 115mm x 80mm x 80mm (LxWxH) Weight approx. 1kg Temperature 5 C - 40 C (operation) Rel. humidity 10% - 90%, non condensing GENERAL DATA Dimensions 175mm x 80mm x 80mm (LxWxH) Weight approx. 1.2kg Temperature 5 C - 40 C (operation) Rel. humidity 10% - 90%, non condensing EM TEST > PAGE 5/6
6 COMPETENCE WHEREVER YOU ARE CONTACT EM TEST DIRECTLY Switzerland USA / Canada EM TEST AG > Sternenhofstraße 15 > 4153 Reinach > Switzerland Phone +41 (0)61/ > Fax +41 (0)61/ Internet: > sales@emtest.ch EM TEST USA Inc. > 3 Northern Blvd. Unit A-4 > Amherst > NH Phone +1 (603) > Fax +1 (603) Internet: > sales@emtest.com Germany P.R. China EM TEST GmbH > Lünener Straße 211 > Kamen > Deutschland Phone +49 (0)2307/ > Fax +49 (0)2307/17050 Internet: > info@emtest.de EM TEST Representative Office Beijing > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing > P.R. China Phone +86 (0) > Fax +86 (0) Internet: > emtestbj@public.bta.net.cn France EM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > Mulhouse > France Phone +33 (0) > Fax +33 (0) Internet: > info@emtest.fr Malaysia EM TEST (M) SDN BHD > Unit B2-6, Jalan Dataran SD2 > Dataran SD2, PJU9 > Bandar Sri Damansara > Kuala Lumpur > Malaysia Phone +60 (03) > Fax +60 (03) Internet: > sales@emtest.com.my Poland EM TEST Polska > ul. Ogrodowa 31/35, Warszawa > Polska Phone +48 (0) Internet: /pl > info.polska@emtest.de Information about scope of delivery, visual design and technical data correspond with the state of development at time of release. Technical data subject to change without further notice. EM TEST > PAGE 6/6
CNI 503X SERIES COMBINED 3-PHASE COUPLING/DECOUPLING NETWORKS FOR BURST AND SURGE TESTING UP TO 10KV
CNI 503X SERIES COMBINED 3-PHASE COUPLING/DECOUPLING NETWORKS FOR BURST AND SURGE TESTING UP TO 10KV FOR TESTS ACCORDING TO... > ANSI/IEEE C62.41 > EN 61000-4-12 > EN 61000-4-4 > EN 61000-4-5 > EN 61000-6-1
More informationCDNS COUPLING / DECOUPLING NETWORKS ACCORDING TO IEC/EN , IEC/EN AND CISPR 15/EN 55015
CDNS COUPLING / DECOUPLING NETWORKS ACCORDING TO IEC/EN 61000-4-6, IEC/EN 60945 AND CISPR 15/EN 55015 FOR TESTS ACCORDING TO... > CISPR 15 > EN 55015 > EN 60945 > EN 61000-4-6 > IEC 60945 > IEC 61000-4-6
More informationPFS 503N SERIES - SIMULATOR FOR DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS
Established 1981 PFS 503N SERIES POWER FAIL SIMULATORS Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) FOR TESTS ACCORDING TO... > EN 61000-4-11 > EN 61000-4-29 > EN 61000-4-34 > EN
More informationVSURGE NX20 1.2/50 US SURGE GENERATOR FOR SOLAR PANEL TESTING
VSURGE NX20 1.2/50 US SURGE GENERATOR FOR SOLAR PANEL TESTING FOR TESTS ACCORDING TO... > EN 61730-1 > EN 61730-2 > IEC 60060 > IEC 61730-1 > IEC 61730-2 > UL 1703 PV PANEL TESTING - 1.2/50US SURGE GENERATOR
More informationCoupling / decoupling network (CDN)
CDN M0, M0B, M, M0B, M, MB IEC/EN 000-- specifies the design and performance of a range of coupling/decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried
More informationAdvanced Test Equipment Rentals ATEC (2832) PSURGE Haefely is a subsidiary of Hubbell Incorporated.
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) PSURGE 8000 Modular expandable surge system www.haefelyemc.com a brand of Haefely is a subsidiary of Hubbell Incorporated.
More informationHa-VIS mcon 3000 Next Generation Introduction and features
Ha-VIS Next Generation Introduction and features Ha-VIS Next Generation es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features The fully Managed es of the
More informationProduct Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications
Product Information ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications January 2009 ECN 1023/EQN 1035 Series Rotary encoders for safety-related applications With integral
More informationExtract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards
Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) compact immunity test system www.axos.haefely.com a brand of Haefely is a subsidiary of Hubbell Incorporated. 2 AXOS
More informationFL SWITCH SFN 5TX. Extract from the online catalog. Order No.:
Extract from the online catalog FL SWITCH SFN 5TX Order No.: 2891152 Ethernet switch, 5 TP RJ45 ports, automatic detection of data transmission rate of 10 or 100 mbps (RJ45), autocrossing function Commercial
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationDIN-Rail Mounting 6-port 100M/Gigabit Layer 2 Unmanaged Industrial PoE Ethernet Switch
IPS316-2GC-4POE DIN-Rail Mounting 6-port 100M/Gigabit Layer 2 Unmanaged Industrial PoE Ethernet Switch Support 2 gigabit Combo ports (SFP slot or RJ45) and 4 100M PoE copper ports The maximum power consumption
More informationTT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage
More informationTF501, TF521 Terminal Bases
Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,
More informationEMOSAFE EN-100 Network Isolators for PCB assembly
ENGLISH EMOSAFE EN-100 Network Isolators for PCB assembly Product Datasheet 1 FEATURES AND ADVANTAGES Suitable for PCB assembly: pluggable or solderable Ultra-compact Conforms to IEC 60601-1 10/100/1000
More informationHEMP & IEMI PROTECTION FILTERS FOR MAINS POWER LINES
HEMP & IEMI PROTECTION FILTERS HEMP & IEMI PROTECTION FILTERS FOR MAINS POWER LINES MEETS ELECTRICAL POINT-OF-ENTRY REQUIREMENTS OF MIL-STD-188-125 PARTS 1 & 2 AND DEF STAN 59-188 PARTS 1 & 2 FOR SHORT
More informationFig. 1: Entry Line Compact Gigabit Ethernet Converter
Entry Line Compact Industrial Fast/Gigabit Ethernet Converter 1x 100/1000Base-T 1x 100/1000Base-X (SFP Slot) MICROSENS General The IP protocol has already left the in-house environment and is going to
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationOvervoltage Protection Devices
Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge
More informationOvervoltage Protection Devices
Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type
More informationOvervoltage Protection Devices
Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type
More informationPCAN-Repeater 2-Channel CAN Repeater with galvanic isolation. User Manual V1.0.0
PCAN-Repeater 2-Channel CAN Repeater with galvanic isolation User Manual V1.0.0 Products taken into account Product Name Model Item Number PCAN-Repeater Industry IPEH-004038 All product names mentioned
More informationTELECOM EQUIPMENT PROTECTION: TRISIL
SMP1LC-xxx TELECOM EQUIPMENT PROTECTION: TRISIL FEATURES Bidirectional crowbar protection Voltage range from 8V to 262V Low capacitance from 3 pf to 45pF typ @ 5V Low leakage current : I R =2µA max Holding
More informationSTEP-PS/1AC/24DC/1.75
Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new
More informationStride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters
Ethernet Switches and Media Converters SE2 Series DIN Rail mounted switches Features Broadcast storm protection Wide temp range option Optional panel mounting accessory 12, 24, 48 VDC & 18-30 VAC redundant
More informationProvisional Product Information. ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications
Provisional Product Information ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications November 2007 ECN 1123/EQN 1135 Series Rotary encoders for safety-related applications With
More informationMED MI 1005 Network Isolators
MED MI 1005 Network Isolators General Network isolators protect patients and medical devices from excessive leakage currents that may flow through the data network. Every device connected to the network
More informationGeneral. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink
Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the
More informationPHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.
More informationTRIO-DIODE/12-24DC/2X10/1X20
Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy
More informationOvervoltage Protection Devices
Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type
More informationIP-Bridge Module for establishing IP connections in 2-wire-based cablings
-Bridge Module for establishing connections in 2-wire-based cablings Third-party integration Compact size Flexible integration Ethernet for 2-wire networks The -Bridge provides an ideal, cost-efficient
More informationHARTING econ 3000 Introduction and features
Introduction and features HARTING econ 3000 es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING econ 3000 are suitable for industrial
More informationIEC ESD Immunity to the discharge of electrostatic electricity
CONDUCTED RF EQUIPMENT POWER AMPLIFIERS IEC 61000-4-2 ESD Immunity to the discharge of electrostatic electricity Markus Fuhrer Electrostatic voltages U [kv] 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 synthetic
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationCharacteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01
HMI unit 560HMR01 Characteristics Application The 560HMR01 is a rack based human machine interface board of the RTU560 system. The essential tasks of the 560HMR01 are: Interface to RTUs that are running
More informationSurge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections
Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation Building Connections Application Camera systems are used to monitor rooms, buildings and outdoor
More informationGEN series G070A. Data sheet. Torque/RPM adapter. Special features
GEN series G070A Torque/RPM adapter Data sheet Special features - Connect up to two torque transducers - Connect to T12/T40B using standard cables - RS422 differential input signals for highest immunity
More informationFL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:
Extract from the online catalog FL SWITCH 8TX Discontinued item Order No.: 2832218 Ethernet Switch, 8 front Ethernet ports in RJ45 format, automatic detection of data transmission speed of 10 or 100 Mbps,
More informationPDD-300 pulsed diode driver
rev 1.08 / 2019 02 13 PDD-300 pulsed diode driver User manual Warning! This equipment may be dangerous. Please read user manual before starting operations. Important note. Please measure output with adequate
More informationABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module MTAC-01 Pulse Encoder Interface Module MTAC-01 User s Manual 3AFE68591091 REV B EN EFFECTIVE: 04.04.2006 2006 ABB Oy. All Rights Reserved. 5 Safety
More informationMGate 5105-MB-EIP Series
MGate 5105-MB-EIP Series 1-port Modbus RTU/ASCII/TCP-to-EtherNet/IP gateways Features and Benefits Protocol conversion between Modbus and EtherNet/IP Supports EtherNet/IP Scanner/Adapter Supports Modbus
More informationPCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )
PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments User Manual Document version 2.0.0 (2018-02-20) Relevant products Product Name Model Part number PCAN-Repeater DR Industry IPEH-004038 PCAN
More informationPCAN-Optoadapter Plug-on Adapter for Decoupling CAN Networks. User Manual. Document version ( )
PCAN-Optoadapter Plug-on Adapter for Decoupling CAN Networks User Manual Document version 3.0.1 (2013-10-21) Products taken into account Product Name Model Part number PCAN-Optoadapter IPEH-002038 CANopen
More informationAdvant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System
Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.
More informationMinilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values
Technical Information Minilog RDL10 Measured value collector with 2 input channels for storing analog and digital values Application Data storage for termperature, humidity, pressure, flow, level, and
More informationQUINT-PS/24DC/48DC/ 5
Extract from the online catalog QUINT-PS/24DC/48DC/ 5 Order No.: 2320128 QUINT DC/DC converter, primary-switched, input: 24 V DC, output: 48 V DC/5 A Commercial data GTIN (EAN) sales group Pack Catalog
More informationPCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual V1.1.0
PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments User Manual V1.1.0 Products taken into account Product Name Model Part Number PCAN-Repeater DR Industry IPEH-004038 All product names mentioned
More informationInstallation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:
Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes
More informationCOUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS
IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq
More informationTN-5308 Quick Installation Guide
TN-5308 Quick Installation Guide Moxa ToughNet Switch Edition 6.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationAttachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female
Extract from the online catalog CN-UB-70DC-6-SB Order No.: 2803153 Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female Commercial data EAN 4046356293204
More informationIP Desktop Intercom Stations 12 NIB 001 Series
IP Desktop Intercom Stations 12 NIB 001 Series Features and Functions IP desktop intercom stations for indoor use 12 keys with protective labels for individual key labeling and multi-color status indication
More informationHigh Voltage Power Supplies
Source voltages up to 5kV and 10kV 1µA current measurement resolution Multi-channel programmable DC power supplies Low noise for precision sourcing and sensitive measurements; selectable filters reduce
More informationMODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.
More informationEnclosed Power Supplies
, 15 150 Watt Features Very compact metal cased power supplies High operating temperature up to 70 C Low no load power consumption
More informationMGate 4101-MB-PBS Series
MGate 4101-MB-PBS Series 1-port Modbus RTU/ASCII-to-PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus and PROFIBUS Supports PROFIBUS DP V0 slave Supports Modbus RTU/ASCII
More informationPCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1
Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10
More informationEnergy Management Modular DC Energy analyzer Type VMU-E and VMU-X
Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.
More informationPart No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version
Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring
More informationDirectory chapter 05. D-Sub Filter subminiature D connectors, 2.54 mm pitch
F Directory chapter 05 D-Sub Filter subminiature D connectors, 2.54 mm pitch New Page General information.............................................. 05.02 Technical characteristics..........................................
More informationBus Connection Unit 560BCU04
Bus Connection Unit 560BCU04 Application The Bus Connection Unit 560BCU04 R0001 is designed to make the RTU560s TSI, TSO, Alarm and Warning signals accessible to the outside. By using the bus connection
More informationAP 701 Access Panel. Features and Functions
AP 701 Access Panel Features and Functions IP desktop intercom station for use in control rooms, control centers, or measuring stations Resistive color touch display for flexible operation with finger,
More informationMODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER
Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware
More informationFeatures and Benefits. Certifications
EDS-P308 Series 8-port unmanaged Ethernet switches with 4 IEEE 802.3af PoE ports Features and Benefits 4 IEEE 802.3af-compliant PoE and Ethernet combo ports Up to 15.4 W output at 48 VDC per PoE port Intelligent
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering
More informationGeneral information. Display. Supply voltage
Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product
More information1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications
UPort 1000 Series 1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters Features and Benefits Hi-Speed USB 2.0 for up to 480 Mbps USB data transmission rates 921.6 kbps maximum baudrate
More informationUser Manual. Installation Industrial Ethernet Rail Switch SPIDER PD SPIDER 1TX/1FX-SM PD EEC
User Manual Installation Industrial Ethernet Rail Switch SPIDER 5TX PD EEC SPIDER 1TX/1FX-MM PD EEC SPIDER 1TX/1FX-SM PD EEC Release 01 06/2012 Technical Support https://hirschmann-support.belden.eu.com
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationGeneral information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes
Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:
More informationKS 108 easy Compact automation unit for industrial control and process technology
PMA KS 108 easy Compact automation unit for industrial control and process technology Combines control, sequencing, and operation Comprehensive function library with integrated operator dialogs BlueDesign
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationEH-RIO IP67 Profibus-DP I/O modules
Installation Instructions EH-RIO IP67 Profibus-DP I/O modules (RIO-PBXDP8M12, -PBXDP8M8, -PBYTP8M12, -PBYTP8M8, -PBXYP8M12, -PBXYP8M8) M12 Style Connectors M8 Style Connectors 43819 The EH-RIO IP67 Profibus-DP
More informationHa-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features
2000 Fast and Full Gigabit Ethernet Basic Commercial Temp.: / Industrial Temp.: Power Sourcing Equipment (PSE) with 4 Ports PoE+ (34.2 watts per port) General description Unmanaged Ethernet switches of
More informationMODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER
Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network
More informationTechnical Overview. Key Features
Agilent P94xA/C Solid State PIN Diode Switches P942A 1 MHz to 8 GHz SPDT PIN switch P942C 1 MHz to 18 GHz SPDT PIN switch P944A 1 MHz to 8 GHz SP4T PIN switch P944C 1 MHz to 18 GHz SP4T PIN switch Technical
More informationOutput Voltage* (nom.)(adjustable)
Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to
More informationCU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:
CU8860-0000 USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: 2006-02-20 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions
More informationUser Manual. Installation Industrial Ethernet Rail Switch SPIDER PD SPIDER 1TX/1FX-SM PD EEC. Installation SPIDER PD Release 02 06/13
User Manual Installation Industrial Ethernet Rail Switch SPIDER PD SPIDER 5TX PD EEC SPIDER 1TX/1FX-MM PD EEC SPIDER 1TX/1FX-SM PD EEC Release 02 06/13 Technische Unterstützung https://hirschmann-support.belden.eu.com
More informationHan R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.
Circular Connector Certified acc to DIN EN ISO 9001 in design/ development, production, installation and servicing Data Sheet 0039-4 Circular Connectors Features Size R 23 Outer diameter 26 mm High contact
More informationInstruction Manual IF2004/USB. 4-Channel RS422/USB Converter
Instruction Manual 4-Channel RS422/USB Converter The following sensors/systems can be connected to the 4-Channel RS422/USB Converter: Sensors of the ILD 1302 / 1402 / 1700 / 2200 / 2300 series Sensors
More informationSPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300
Profibus-DPV1/SPA Gateway SPA-ZC 302 Product Guide spa-zc302_rightco300 Issued: 25.11.2003 Status: Updated Version: D/16.05.2008 Data subject to change without notice Features Profibus DP Version 1 connectivity
More information16-Channel Digital Input Termination Card 24Vdc
TDI16BIA 16-Channel Digital Input Termination Card 24Vdc (TDI16BIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16BIA16-channel digital input termination card acts as an interface between the digital
More informationRugged MediaConverter
Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006
More informationMGate 5102-PBM-PN Series
MGate 5102-PBM-PN Series 1-port PROFIBUS-to-PROFINET gateways Features and Benefits Protocol conversion between PROFIBUS and PROFINET Supports PROFINET IO device Supports PROFIBUS DP V1 master Automatic
More informationQFBR-S01IN001Z. Optical Phase Interrogator. Data Sheet. Description. Features. Applications
Optical Phase Interrogator Description The QFBR-S01IN001Z is a versatile optical phase interrogation (OPI) unit based on Avago proprietary technology. The working principle is based on comparing a fixed
More informationData Sheet. QFBR-S01IN001Z Optical Phase Interrogator. Description. Features. Applications
QFBR-S01IN001Z Optical Phase Interrogator Data Sheet Description Avago technologies QFBR-S01IN001Z is a versatile optical phase interrogation (OPI) unit based on Avago proprietary technology. The working
More informationPHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
More information07. har-link Interface Connectors
. Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationPlug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar
Plug-in module SIRAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SIRAX TV 808 (Fig. ) is to electrically insulate
More informationPHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 103349_en_00 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic
More informationPointMaster 100. Multipoint Recorder 10/ EN
PointMaster 1 Multipoint Recorder 1/41-1.1 EN 6 Measuring channels Last dot visible from the front Measuring channels electrically isolated and ungrounded Connection of process signals / 4...2 ma,...1
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationPHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both
More informationSMP75. Trisil for telecom equipment protection. Features. Description. Applications. Benefits
Trisil for telecom equipment protection Features bidirectional crowbar protection voltage: 8 V low leakage current: I R = 2 µa max holding current: I H = 15 ma min repetitive peak pulse current: I PP =
More informationCPT-COM-U Card. TTL Serial USB Isolated Interface Board. Technical Brief
CPT-COM-U Card TTL Serial USB Isolated Interface Board Technical Brief June 2014 Manual Release 1.0 Card Version 1.1 Copyright 2014 Creative Power Technologies P/L P.O. Box 714 MULGRAVE Victoria, 3170
More information