PG&E Transmission Interconnection Handbook

Size: px
Start display at page:

Download "PG&E Transmission Interconnection Handbook"

Transcription

1 Table of Contents TABLE OF CONTENTS... 1 UPDATE HISTORY... UP-1 INTRODUCTION... IN-1 I-1. PURPOSE... IN-1 I-2. INTRODUCTORY DEFINITIONS... IN-1 I-3. HANDBOOK APPLICABILITY... IN-2 I-3.1. New Load, New Transmission and Generation Facilities... IN-2 I-3.2. Existing Load or Transmission Facilities... IN-2 I-3.3. Existing Generation Facilities... IN-3 I-4. ELECTRIC INDUSTRY RESTRUCTURING... IN-3 I-5. PROCEDURES FOR DEVELOPING TRANSMISSION PLANS AND COORDINATED JOINT STUDIES... IN-4 I-5.1. Procedures for Developing Transmission Plans... IN-4 I-5.2. Procedures for Coordinated Joint Studies... IN-5 I-6. ORGANIZATION OF HANDBOOKS... IN-5 I-7. STANDARD AND PROJECT-SPECIFIC INTERCONNECTION REQUIREMENTS... IN-6 I-8. CUSTOMER-OWNED EQUIPMENT REQUIREMENTS... IN-6 I-9. COMPLIANCE WITH NERC INTERCONNECTION STANDARDS... IN-7 I-10. GENERAL RECOMMENDATIONS CONCERNING THE CONTENTS OF LOCAL CEQA DOCUMENTS... IN-10 I EIR adopted with significant and unavoidable impacts in any environmental impact categories... IN-10 I First section in your document... IN-10 I Mitigation Measures v. APMs... IN-11 I Not Obligating PG&E... IN-11 I Local Ordinances... IN-11 I Building Code Exemption... IN-12 I General Worst-Case Assumptions... IN-12 I Impact analyses sections... IN-13 I Aesthetics... IN-13 I GHG analysis... IN-13 I GHG APMs... IN-14 I SF 6 -specific APMs... IN-14 GLOSSARY... GL-1 SECTION L1-D: REVENUE-METERING REQUIREMENTS FOR DISTRIBUTION LOAD-ONLY ENTITIES... L1-D-1 PURPOSE... L1-D-1 L1-D.1. REVENUE METERING REQUIREMENTS FOR LOAD ENTITIES... L1-D-1 L1-D.1.1. Wholesale Service... L1-D-1 L1-D.1.2. End Users (Retail Service)... L1-D-1 L1-D PG&E Direct Access Rule L1-D-1 L1-D PG&E, as an MSP, will provide, install, maintain and test the following meter equipment... L1-D-2 L1-D PG&E, as an MDMA, will provide the following meter data services... L1-D-2 L1-D All PG&E Load Entities will provide, install and maintain... L1-D-3 L1-D.2. REQUIREMENTS OF REVENUE-METERING POINT... L1-D-4 L1-D.3. COMMUNICATION CIRCUITS... L1-D-4 L1-D.4. GROUND POTENTIAL RISE... L1-D-5 SECTION L1-T: REVENUE-METERING REQUIREMENTS FOR TRANSMISSION-ONLY AND LOAD- ONLY ENTITIES... L1-T-1 PURPOSE... L1-T-1 i

2 L1-T.1. REVENUE-METERING REQUIREMENTS FOR LOAD ENTITIES AND TRANSMISSION ENTITIES CONNECTING LOAD TO THE PG&E TRANSMISSION SYSTEM... L1-T-1 L1-T.1.1. Wholesale Service... L1-T-1 L1-T.1.2. End User (Retail Service)... L1-T-1 L1-T Bundled Service... L1-T-2 L1-T Direct Access Service... L1-T-2 L1-T Equipment Requirements:... L1-T-3 L1-T.1.3. Additional Requirements... L1-T-4 L1-T.2. LOCATION OF REVENUE METERING POINT... L1-T-5 L1-T.3. COMMUNICATIONS CIRCUITS... L1-T-6 FORM L L1-T-7 SECTION L2: PROTECTION AND CONTROL REQUIREMENTS FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES... L2-1 PURPOSE... L2-1 APPLICABILITY... L2-1 L2.1. PROTECTIVE RELAY REQUIREMENTS... L2-1 L2.2. RELIABILITY AND REDUNDANCY... L2-3 L2.3. RELAY SPECIFICATIONS RELIABILITY AND REDUNDANCY... L2-3 L2.4. LINE PROTECTION... L2-4 L Fault-Interrupting Devices... L2-5 L Circuit Breakers... L2-6 L Circuit Switchers... L2-6 L Fuses... L2-7 L Relay Class Current Transformers (CT)... L2-7 L2.5. STANDBY/BACKUP SOURCE... L2-8 L Standby Source... L2-8 L Backup Generators... L2-8 SECTION L3: SUBSTATION DESIGN FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES... L3-1 PURPOSE... L3-1 L3.1. DEAD-END STRUCTURE... L3-1 L3.2. TRANSFORMERS... L3-1 L3.3. VOLTAGE REGULATION... L3-2 L3.4. POWER FACTOR... L3-3 L3.5. CIRCUIT BREAKER OR OTHER FAULT INTERRUPTING DEVICES... L3-3 L3.6. RULES FOR TAPPING TRANSMISSION LINES... L3-3 L3.7. SWITCHES... L3-4 L Manual Disconnects... L3-4 L Tap Switch... L3-5 L Line Selector Switches... L3-5 L3.8. INTERCONNECTION OF LOAD ENTITY S OR TRANSMISSION ENTITY S SUBSTATION WITH PG&E S SYSTEM... L3-5 L3.9. LOAD ENTITY OR TRANSMISSION ENTITY INTERFERENCE WITH POWER QUALITY... L3-6 SECTION L4: OPERATING PROCEDURES AND REQUIREMENTS FOR LOAD-ONLY AND TRANSMISSION-ONLY ENTITIES... L4-1 PURPOSE... L4-1 APPLICABILITY... L4-1 L4.1. JURISDICTION OF THE ISO AND THE DESIGNATED PG&E CONTROL CENTER... L4-1 L4.2. COMMUNICATIONS... L4-1 L4.3. ATTENDED LOAD FACILITIESOR TRANSMISSION FACILITIES REQUIREMENTS... L4-2 L Voltage Control Device Operation and Special Service Requirements... L4-2 L Connecting and Separating from the Power System... L4-2 L Clearances and Switching Requests... L4-2 ii

3 L Unusual or Emergency Conditions... L4-2 L Other Communications... L4-3 L4.4. UNATTENDED LOAD FACILITIES REQUIREMENTS... L4-4 L Verification of Energized Circuit... L4-4 L Separation/Restoration... L4-4 L4.5. SPECIAL SERVICE REQUIREMENTS... L4-4 L4.6. LOAD ENTITY OR TRANSMISSION ENTITY INTERFERENCE WITH POWER QUALITY... L4-4 SECTION L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES... L5-1 PURPOSE... L5-1 L5.1. TESTS REQUIRED FOR LOAD ENTITIES PRIOR TO ENERGIZING... L5-1 L Proving Insulation... L5-1 L Proving Ratios... L5-2 L Circuit Breakers and Circuit Switchers... L5-2 L Current Transformers and Current Circuits... L5-2 L Relays... L5-3 L Primary Disconnect Switch... L5-3 L Station Battery... L5-3 L5.2. ENERGIZING... L5-3 L5.3. GENERAL NOTES... L5-4 CONTACT INFORMATION SHEET... L5-5 SECTION G1: METERING REQUIREMENTS FOR TRANSMISSION GENERATION ENTITIES... G1-1 PURPOSE:... G1-1 APPLICABILITY... G1-1 G1.1. BASIC METERING REQUIREMENTS FOR GENERATORS... G1-1 G1.2. DETAILED METERING REQUIREMENTS FOR GENERATORS... G1-3 G Metering Configurations For New Generators... G1-3 G Metering Requirements For New Generators... G1-3 G Wholesale Generators... G1-3 G Metering Generator s Loads... G1-4 G1.3. TELEMETERING REQUIREMENTS FOR GENERATOR MONITORING... G1-4 G For New Generation Facilities 1,000 kw or Greater... G1-4 G For New Generation Facilities Less Than 1,000 kw... G1-4 G1.4. METERING CURRENT AND VOLTAGE TRANSFORMERS FOR GENERATORS... G1-4 SECTION G2: PROTECTION AND CONTROL REQUIREMENTS FOR TRANSMISSION GENERATION ENTITIES... G2-1 PURPOSE... G2-1 APPLICABILITY... G2-1 G2.1. PROTECTIVE RELAY REQUIREMENTS... G2-1 G2.2. RELIABILITY AND REDUNDANCY... G2-3 G2.3. RELAY GRADES... G2-4 G2.4. LINE PROTECTION... G2-4 G2.5. GENERATOR PROTECTION AND CONTROL... G2-7 G Phase Overcurrent... G2-9 G Over/Undervoltage Relay... G2-9 G Over/Underfrequency Relay... G2-9 G Ground and Phase Fault Sensing Scheme... G2-9 G General:... G2-9 G Ground Grid Requirements... G2-9 G Overcurrent Relay with Voltage Restraint/Voltage Control or Impedance Relay... G2-10 G Reverse Power Relay... G2-10 G2.6. DEDICATED TRANSFORMER... G2-10 G2.7. MANUAL DISCONNECT SWITCH... G2-11 G General... G2-11 iii

4 G Specifications... G2-12 G2.8. FAULT-INTERRUPTING DEVICES... G2-12 G Circuit Breakers... G2-12 G Circuit Switchers... G2-13 G Relay Class Current Transformers (CT)... G2-13 G2.9. SYNCHRONOUS GENERATORS... G2-13 G Synchronizing Relays... G2-13 G Automatic Synchronizers Approved by PG&E See Table G2-4 for PG&E-approved devices.. G2-14 G Automatic Synchronizers (not on PG&E s approved list) Supervised by a PG&E-Approved Synchronizing Relay... G2-14 G Manual Synchronization Supervised by a Synchronizing Relay... G2-14 G Manual Synchronization With Synch-Check Relay... G2-15 G Frequency/Speed Control... G2-15 G Excitation System Requirements... G2-15 G Voltage Regulator... G2-16 G Power Factor Controller... G2-17 G2.10. INDUCTION GENERATORS... G2-17 G2.11. DC GENERATORS... G2-17 G Inverters Capable of Stand-Alone Operation... G2-17 G Inverters Incapable of Stand-Alone Operation... G2-18 G2.12. SPECIAL PROTECTION SYSTEMS... G2-19 G2.13. REMEDIAL ACTION SCHEME (RAS) PARTICIPATION REQUIREMENT FOR GENERATION FACILITIES... G2-19 G2.14. EVENT RECORDER... G2-20 G2.15. EMERGENCY GENERATOR REQUIREMENTS... G2-20 G Break Before Make... G2-20 G Make Before Break... G2-20 G Interconnection Requirements... G2-20 G Interconnection Protection Study... G2-21 G Transfer Switch... G2-21 G Notification and Documentation... G2-21 G Operation/Clearance... G2-21 G Break Before Make Specific Requirements... G2-21 G Transfer Switch... G2-21 G Make Before Break Requirements... G2-22 G Transfer Switch... G2-22 G Manual Disconnect... G2-22 G Synchronizing Function... G2-22 G Protection... G2-23 G Dedicated Transformer... G2-23 G2.16. PARALLEL-ONLY (NO SALE) GENERATOR REQUIREMENT... G2-23 G2.17. GENERATION ENTITY-OWNED PRIMARY OR TRANSMISSION VOLTAGE TAP LINES (60 KV AND ABOVE)... G2-24 G2.18. PG&E PROTECTION AND CONTROL SYSTEM CHANGES WHICH MAY BE REQUIRED TO ACCOMMODATE GENERATOR INTERCONNECTION... G2-24 G2.19. DIRECT TELEPHONE SERVICE... G2-25 G2.20. STANDBY STATION SERVICE... G2-25 G2.21. STATION BATTERY... G2-25 SECTION G3: OPERATING REQUIREMENTS FOR TRANSMISSION GENERATIN ENTITIES... G3-1 PURPOSE... G3-1 APPLICABILITY... G3-1 G3.1. REACTIVE AND VOLTAGE COLTROL REQUIREMENTS FOR GENERATORS... G3-1 G Synchronous Generator Control... G3-2 G Frequency/Speed Control... G3-2 G Voltage Control... G3-2 G Power System Stabilizer Operating Requirements For Generators... G3-2 G Power Factor Control... G3-2 G Non-Synchronous Generator Control (without Var Control)... G3-3 iv

5 G Induction Generators Larger Than 40 kw... G3-3 G Inverter-Based Generating Facilities... G3-3 G3.2. GENERATOR STEP-UP TRANSFORMER... G3-4 G3.3. POWER QUALITY REQUIREMENTS... G3-4 G Voltage Fluctuation Limits... G3-4 G Harmonic Limits... G3-4 G3.4. VOLTAGE RIDE-TROUGH REQUIREMENTS... G3-5 SECTION G4: OPERATING PROCEDURES FOR TRANSMISSION GENERATION ENTITIES... G4-1 PURPOSE... G4-1 APPLICABILITY... G4-1 G4.1. JURISDICTION OF THE CAISO AND THE PG&E GRID CENTER (GCC)... G4-1 G4.2. COMMUNICATIONS... G4-1 G Daily Capacity and Energy Reports... G4-2 G Voltage Control Operation and Other Service Requirements... G4-2 G Paralleling to and Separating from PG&E (Attended Generating Facilities Only)... G4-3 G Clearances and Switching Requests... G4-3 G Unusual or System Emergency Conditions... G4-3 G Emergency/Backup Generators... G4-4 G Other Communications... G4-4 G4.3. UNATTENDED GENERATING FACILITIES... G4-5 G Verification of Energized Circuit... G4-5 G Loss of Power/Automatic Re-paralleling... G4-5 G Event Recorder... G4-6 G4.4. PROCEDURES ON TRANSFER TRIP PROTECTION FOR GENERATION FACILITIES... G4-6 G Purpose and Definition... G4-6 G Separation Following Loss of Transfer-Trip Protection... G4-7 G Procedures... G4-7 G Separation Orders... G4-8 G Non-Compliance Separation Order... G4-8 G Re-parallel of Generating Facility After Restoration of TT Protection... G4-8 G4.5. GENERATION ENTITY INTERFERENCE WITH POWER QUALITY... G4-9 SECTION G5: ENERGIZATION AND SYNCHRONIZATION REQUIREMENTS FOR TRANSMISSION GENERATION ENTITIES... G5-1 PURPOSE... G5-1 G5.1. TEST RESULTS AND/OR INFORMATION REQUIRED PRIOR TO PRE-PARALLEL TESTING... G5-1 G Proving Insulation... G5-1 G Proving Ratios... G5-2 G Circuit Breakers and Circuit Switchers... G5-2 G Current Transformers and Current Circuits... G5-2 G Relays... G5-3 G Primary Disconnect Switch... G5-3 G RTU/RIG/DPU... G5-3 G Station Battery... G5-3 G5.2. PRE-PARALLEL INSPECTION (PPI)... G5-3 G Functional Tests... G5-4 G Data Telemetry Tests... G5-4 G5.3. REQUIREMENTS FOR PARALLEL GENERATOR OPERATION... G5-5 G Clearance for Parallel Operation (For Testing Purposes Only)... G5-5 G Impedance and Directional Relay Tests... G5-5 G Generator Load Tests... G5-6 G Power System Stabilizer (PSS)... G5-6 G Model Testing and Validation Report... G5-8 G Signage Requirements... G5-8 v

6 G5.4. PERMISSION TO COMMENCE COMMERCIAL OPERATION... G5-8 G5.5. GENERAL NOTES... G5-9 SECTION G6: SITING POLICY AND REQUIREMEENTS FOR TRANSMISSION GENERATION ENTITIES... G6-1 PURPOSE... G6-1 APPLICABILITY... G6-1 POLICY... G6-1 G6.1. CRITERIA FOR NEW OR PROPOSED RE-POWERING PROJECTS... G6-1 G /70 kv, 115kV, 230kV & 500kV TRANSMISSION FACILITIES... G6-1 G GENERATOR TAP LINES... G6-1 APPENDIX A: WHERE TO OBTAIN REFERENCE DOCUMENTS AND INFORMATION... AA-1 APPENDIX D: ENGINEERING NUMBERED DOCUMENTS... AD-1 APPENDIX F: TELEMETERING AND TRANSFER TRIP FOR TRANSMISSION GENERATION ENTITIES... AF-1 F.0. NOTIFICATION... AF-2 F.1. APPLICATIONS... AF-2 F.2. GENERAL REQUIREMENTS... AF-3 F2.1. EMS/SCADA Telemetering... AF-4 F SCADA Telemetering for all Generation Facilities... AF-4 F EMS/SCADA Telemetering for Generation Facilities 1 MW or Greater... AF-5 F2.2. Protection... AF-6 F2.3. Business Telephone and Revenue Metering... AF-9 F2.4. Environmental Considerations.... AF-9 F.3. INSTALLATION OF LEC ENTRANCE CABLE IN SUBSTATIONS (RISK - SEE SECTION F.0. NOTIFICATION)... AF-10 F.4. CIRCUIT REQUIREMENTS FOR PROTECTIVE RELAYING AND EMS/SCADA CIRCUITS INSTALLED BETWEEN GENERATION FACILITY STATIONS AND PG&E POWER SUBSTATIONS (RISK - SEE SECTION F.0. NOTIFICATION)... AF-10 F.5. ADDITIONAL DIRECT TRANSFER TRIP (DTT) TELECOMMUNICATION OPTIONS... AF-12 F.5.1. Option 1. All Fiber... AF-12 F.5.2. Option 2. Fiber / Channelized T1 using fiber based HVP protection... AF-13 F5.3. Option 3 - Copper / Channelized T1 using copper HVP... AF-14 F.6. DEFINITIONS... AF-15 F7.0 FIGURES... AF-17 APPENDIX H: POWER SYSTEM STABILIZER... AH-1 APPENDIX I: LOAD OPERATING AGREEMENT... AI-1 PURPOSE... AI-1 APPLICABILITY... AI-1 ATTACHMENT... AI-1 APPENDIX J: SPECIAL AGREEMENT FOR ELECTRICAL STANDBY SERVICE... AJ-1 PURPOSE... AJ-1 APPLICABILITY... AJ-1 RELEVANT DOCUMENTS... AJ-1 APPENDIX K: LOAD SPECIAL FACILITIES AGREEMENT... AK-1 APPENDIX L: INTERCONNECTION AGGREMENTS FOR GENERATORS CONNECTING TO THE ISO CONTROLLED GRID... AL-1 PURPOSE AND APPLICABILITY... AL-1 RELEVANT DOCUMENTS... AL-1 APPENDIX M: GENERATION INTERCONNECTION DATA SHEET... AM-1 vi

7 APPENDIX N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM... AN-1 APPENDIX Q: GENERATOR AUTOMATIC SYNCHRONIZERS FOR GENERATION ENTITIES... AQ-1 Q1.1. OPERATION AND PERFORMANCE REQUIREMENTS...AQ-1 APPENDIX R: PROTECTIVE RELAY REQUIREMENTS AND APPROVALS... AR-1 R.1. REQUIREMENTS... AR-2 APPENDIX S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS... AS-1 S1. STANDARD INTERCONNECTION METHODS WITH TYPICAL CIRCUIT CONFIGURATION FOR SINGLE OR MULTIPLE UNITS... AS-1 S1.1. Generator Connected Into a Ring Bus... AS-1 S1.2. Generator Connected Into a Breaker-and A-Half (BAAH) Bus... AS-1 S1.3. Bus Fault Clearing... AS-2 S2. INTERCONNECTION METHODS WITH SPECIAL CIRCUIT CONFIGURATIONS FOR SINGLE UNIT... AS-2 S2.1. Alternative--Generator Tapping To Existing Transmission Line between Two Terminals, considered only at voltages below 230kV... AS-2 S2.3. Generator Tapping closely outside the Substation Between Two Existing Terminals... AS-3 S2.4. Generator Connected Close Outside the Substation with a Dedicated Line... AS-4 S2.5. Requirements for S2.3 and S2.4 Alternatives... AS-4 S2.6. Additional Items for Consideration... AS-5 APPENDIX T: BATTERY REQUIREMENTS FOR INTERCONNECTION TO PG&E SYSTEM... AT-1 vii

PG&E Transmission Interconnection Handbook. Update Section Date Added Figure G5-1 Simplified Flow Chart of Pre- Section G5 Aug.

PG&E Transmission Interconnection Handbook. Update Section Date Added Figure G5-1 Simplified Flow Chart of Pre- Section G5 Aug. Update History PG&E Transmission Interconnection Hbook Added Figure G5-1 Simplified Flow Chart of Pre- Section G5 Aug. 11, 2004 Parallel/Parallel Test Procedure. Addition of F-35 GE device to Table G2-4

More information

Generation, Transmission, and End User Facilities

Generation, Transmission, and End User Facilities Procedures for Interconnection of Generation, Transmission, and End User To the Grand River Dam Authority Transmission System Table of Contents GRDA/SPP Interaction... 3 Standards... 3 Generation... 3

More information

Transmission Interconnection Handbook, Appendix F. System protection, generation interconnection, substation test, and telecommunication personnel

Transmission Interconnection Handbook, Appendix F. System protection, generation interconnection, substation test, and telecommunication personnel Utility Bulletin: TD-1013B-002 Publication Date: 07/03/2012 Rev: 0 Direct Transfer Trip (DTT) Telecommunication Options Summary Interconnection partners (customers) are requesting additional options for

More information

Glencoe Light and Power

Glencoe Light and Power Glencoe Light and Power REQUIREMENTS FOR GENERATION, TRANSMISSION, AND END-USER FACILITY INTERCONNECTIONS 1 Table of Contents Page I. INTRODUCTION...5 A. Authority... 5 B. Objectives...5 C. Interconnection

More information

MONTANA-DAKOTA UTILITIES REQUIREMENTS FOR GENERATION, TRANSMISSION, AND END-USER FACILITY INTERCONNECTIONS

MONTANA-DAKOTA UTILITIES REQUIREMENTS FOR GENERATION, TRANSMISSION, AND END-USER FACILITY INTERCONNECTIONS MONTANA-DAKOTA UTILITIES REQUIREMENTS FOR GENERATION, TRANSMISSION, AND END-USER FACILITY INTERCONNECTIONS Table of Contents I. Introduction... 5 A. Authority... 5 B. Objectives... 5 C. Interconnection

More information

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS This standard was reviewed and approved by key managers on. Officer approval of this revision is not required. 1.0 SCOPE 1.1 This guide applies to the interconnection of a generating plant with the Oncor

More information

ITC Facility Connection Requirements for Generation, Transmission and End-User Facilities Connected to the ITC Holdings Transmission Systems

ITC Facility Connection Requirements for Generation, Transmission and End-User Facilities Connected to the ITC Holdings Transmission Systems ITC Facility Connection Requirements for Generation, Transmission and End-User Facilities Connected to the ITC Holdings Transmission Systems Category: Planning Type: Policy Eff. Date/Rev. # 06/19/2017

More information

SPECIFIC INTERCONNECTION PROTECTION REQUIREMENTS... 5

SPECIFIC INTERCONNECTION PROTECTION REQUIREMENTS... 5 Central Hudson Gas & Electric Corporation (CHG&E) Interconnection Protection Requirements for Distributed Generators of Greater than 300 kva Connected in Parallel with the CHG&E Electrical Delivery System

More information

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW The Customer Generator applicant ("Applicant") hereby makes application to the T &

More information

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9 PJM Manual 07: PJM Protection Standards Revision: 3 Effective Date: May 24, 2018 Prepared by System Planning Division Transmission Planning Department PJM 2018 Table of Contents Table of Contents Approval...6

More information

REAL-TIME MONITORING DATA SPECIFICATION

REAL-TIME MONITORING DATA SPECIFICATION REAL-TIME MONITORING DATA SPECIFICATION Version 1 December 9, 2016 Revision History Version Date Reviewer Revisions 1 11/1/16 Mansion Hudson Initial document 1 Contents 1. DOCUMENT REVIEW... 3 2. DEFINITIONS...

More information

SOUTH TEXAS ELECTRIC COOPERATIVE, INC.

SOUTH TEXAS ELECTRIC COOPERATIVE, INC. SOUTH TEXAS ELECTRIC COOPERATIVE, INC. P.O. Box 119 Nursery, Texas 77976 (361) 575-6491 Fax (361) 576-1433 Transmission Interconnection Requirements Table of Contents I. Introduction II. Interconnection

More information

THE INTERCONNECTION HANDBOOK

THE INTERCONNECTION HANDBOOK THE INTERCONNECTION HANDBOOK Southern California Edison Company Rev. 8 This document is controlled by the originating SCE T&D organization. When downloaded and printed, this document becomes UNCONTROLLED,

More information

Small Generator Interconnection Facilities Study Report. Completed for Q0314 ( Interconnection Customer ) A Qualified Facility

Small Generator Interconnection Facilities Study Report. Completed for Q0314 ( Interconnection Customer ) A Qualified Facility Small Generator Interconnection Completed for Q0314 ( Interconnection Customer ) A Qualified Facility Proposed Interconnection PacifiCorp s 34.5-kV West Cedar Substation December 29, 2010 TABLE OF CONTENTS

More information

Facility Connection Requirements. LST-FAC-001-PRO-Facility_Connection_Requirements

Facility Connection Requirements. LST-FAC-001-PRO-Facility_Connection_Requirements Facility Connection Requirements LST-FAC-001-PRO-Facility_Connection_Requirements Document Control Document Owner: Name: Mathew Gomes Title: Director of Development & System Planning Change History: The

More information

INTERCONNECTION FACILITIES STUDY REPORT

INTERCONNECTION FACILITIES STUDY REPORT Interconnection Request No. TI-08-0312 INTERCONNECTION FACILITIES STUDY REPORT Prepared by Tri-State Generation and Transmission Association, Inc. 1 of 7 DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES

More information

Requests for Clarifications And Responses Order No. 754 Data Request The Study of Single Point of Failure

Requests for Clarifications And Responses Order No. 754 Data Request The Study of Single Point of Failure Requests for Clarifications And Responses Order No. 754 Data Request The Study of Single Point of Failure Revised: July 12, 2013 Introduction The following information includes requests for clarification

More information

Revision 6.0. Transmission Interconnection Guide

Revision 6.0. Transmission Interconnection Guide Revision 6.0 Transmission Interconnection Guide AMERICAN TRANSMISSION COMPANY Transmission Transmission Interconnection Guide Revision 6.0 December 15, 2017 American Transmission Company W234 N2000 Ridgeview

More information

JEA. Facility Connection Requirements

JEA. Facility Connection Requirements JEA Facility Connection Requirements April 2008 January 14 th, 2006 1/22 JEA Facility Connection Requirements TABLE OF CONTENTS 1.0 Introduction and Scope 1.1 Generation Facilities 1.2 Transmission Facilities

More information

INTERCONNECTION FACILITIES STUDY REPORT

INTERCONNECTION FACILITIES STUDY REPORT INTERCONNECTION FACILITIES STUDY REPORT NORTHEAST WYOMING 250MW GENERATOR Prepared on Behalf of the Transmission Provider: Basin Electric Power Cooperative Transmission Black Hills Power Transmission December

More information

SMALL GENERATOR INTERCONNECTION REQUEST. (Application Form)

SMALL GENERATOR INTERCONNECTION REQUEST. (Application Form) Attachment 2 Transmission Provider: SMALL GENERATOR INTERCONNECTION REQUEST Designated Contact Person: Address: Telephone Number: (Application Form) An Interconnection Request is considered complete when

More information

Appendix I: LOAD OPERATING AGREEMENT

Appendix I: LOAD OPERATING AGREEMENT PG&E Transmission Interconnection Handbook Appendix I: LOAD OPERATING AGREEMENT Purpose The following agreement establishes operating responsibilities and associated procedures for communications between

More information

Electric Utility Facility Connection Requirements

Electric Utility Facility Connection Requirements City of Coffeyville Municipal Light and Power Electric Utility Facility Connection Requirements Approved: Date: Version Date Change Tracking Reviewer/Editor 1.0 June, 2010 Original document. Steve McGie

More information

Interconnection and Transmission

Interconnection and Transmission Interconnection and Transmission Gary L. Brown, P.E. Director of Energy Development Gary@ZGlobal.biz 916-985-9461 Kevin Coffee Energy Management Committee Meeting Irvine, California August 26, 2015 Interconnection

More information

Superseding REVISED SHEET NO. 34D-8 REVISED SHEET NO. 34D-8 Effective May 27, 2010 Effective December 3, 2011

Superseding REVISED SHEET NO. 34D-8 REVISED SHEET NO. 34D-8 Effective May 27, 2010 Effective December 3, 2011 Superseding REVISED SHEET NO. 34D-8 REVISED SHEET NO. 34D-8 2. Initial Technical Review a. The following flowchart provides, for illustrative purposes, the major steps in the Initial Technical Review process:

More information

For the State of Washington SMALL GENERATOR INTERCONNECTION REQUEST (Tier 1 [Non-Net Meter], Tier 2, Tier 3) (Application Form)

For the State of Washington SMALL GENERATOR INTERCONNECTION REQUEST (Tier 1 [Non-Net Meter], Tier 2, Tier 3) (Application Form) Electrical Company: PacifiCorp For the State of Washington SMALL GENERATOR INTERCONNECTION REQUEST (Tier 1 [Non-Net Meter], Tier 2, Tier 3) (Application Form) Designated Contact Person: Robin Moore Address

More information

Document C0. Use for:

Document C0. Use for: Date: July 27, 2015 Document C0 Use for: Connection of Electric Generation that will operate with an Open Transition (Category 1) between the Ameren System and the Generator or operate with a Synchronized

More information

SCADA Training - T&D Automation

SCADA Training - T&D Automation SCADA Training - T&D Automation Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq This course covers all the

More information

INTERCONNECTION STANDARDS FOR GENERATING FACILITIES (GF) CONNECTED TO THE FORT COLLINS DISTRIBUTION SYSTEM. July 2011 UPDATED STANDARDS

INTERCONNECTION STANDARDS FOR GENERATING FACILITIES (GF) CONNECTED TO THE FORT COLLINS DISTRIBUTION SYSTEM. July 2011 UPDATED STANDARDS INTERCONNECTION STANDARDS FOR GENERATING FACILITIES (GF) CONNECTED TO THE FORT COLLINS DISTRIBUTION SYSTEM July 2011 UPDATED STANDARDS Rev 9.0 July 2011 2 TABLE OF CONTENTS 1.0 SCOPE AND GENERAL REQUIREMENTS...5

More information

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: _Cleco Power LLC Designated Contact Person: Cindy Guillot Address: P.O Box 70, (2180 St. Landry Hwy) St. Landry, LA 71367

More information

XXXX. Bear Creek Hydro Generation Project. Interconnection Facilities Study

XXXX. Bear Creek Hydro Generation Project. Interconnection Facilities Study XXXX Bear Creek Hydro Generation Project Interconnection Facilities Study Report No. SPA 2005-33 August 2005 System Planning (Lower Mainland & Vancouver Island) British Columbia Transmission Corporation

More information

PUBLIC SERVICE OF NEW HAMPSHIRE. Technical Requirements for Non Utility Generation Interconnecting to the PSNH Distribution System

PUBLIC SERVICE OF NEW HAMPSHIRE. Technical Requirements for Non Utility Generation Interconnecting to the PSNH Distribution System PUBLIC SERVICE OF NEW HAMPSHIRE Technical Requirements for Non Utility Generation Interconnecting to the PSNH Distribution System September 2013 1.0 Purpose of this document Public Service of New Hampshire

More information

High and Medium Voltage Substation Design, Testing and Maintenance. KSA, Jeddah, Holiday Inn Jeddah Gateway Hotel.

High and Medium Voltage Substation Design, Testing and Maintenance. KSA, Jeddah, Holiday Inn Jeddah Gateway Hotel. Training Course : High and Medium Voltage Substation Design, Testing and Maintenance Training Course For One Week In KSA, Jeddah, Holiday Inn Jeddah Gateway Hotel Which Be Held As Under Details : Tel.

More information

BULK POWER SYSTEM FACILITY AND END USER INTERCONNECTION REQUIREMENTS TO THE LIPA TRANSMISSION SYSTEM

BULK POWER SYSTEM FACILITY AND END USER INTERCONNECTION REQUIREMENTS TO THE LIPA TRANSMISSION SYSTEM BULK POWER SYSTEM FACILITY AND END USER INTERCONNECTION REQUIREMENTS TO THE LIPA TRANSMISSION SYSTEM April 13, 2007 LIPA Facility Connection Requirements TABLE OF CONTENT I. INTRODUCTION...1 II. REFERENCE

More information

Substation SCADA Monitoring

Substation SCADA Monitoring Substation SCADA Monitoring Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq Substations are a critical component

More information

LONG ISLAND POWER AUTHORITY INTERCONNECTION REQUIREMENTS FOR NEW DISTRIBUTED GENERATION GREATER THAN 300 KVA OPERATING IN PARALLEL WITH LIPA S RADIAL

LONG ISLAND POWER AUTHORITY INTERCONNECTION REQUIREMENTS FOR NEW DISTRIBUTED GENERATION GREATER THAN 300 KVA OPERATING IN PARALLEL WITH LIPA S RADIAL LONG ISLAND POWER AUTHORITY INTERCONNECTION REQUIREMENTS FOR NEW DISTRIBUTED GENERATION GREATER THAN 300 KVA OPERATING IN PARALLEL WITH LIPA S RADIAL DISTRIBUTION SYSTEM Revised and Issued March 2003 I.

More information

Information Document PRC-001-AB3-1.1(ii) Protection System Coordination ID # RS

Information Document PRC-001-AB3-1.1(ii) Protection System Coordination ID # RS Information Documents are not authoritative. Information Documents are for information purposes only and are intended to provide guidance. In the event of any discrepancy between an Information Document

More information

Substation Automation Products. Line differential protection RED670 Relion 670 series

Substation Automation Products. Line differential protection RED670 Relion 670 series Substation Automation Products Line differential protection RED670 Relion 670 series For maximum reliability of your power system The RED670 IED (Intelligent Electronic Device) is designed for protection,

More information

ELG4125: System Protection

ELG4125: System Protection ELG4125: System Protection System Protection Any power system is prone to 'faults', (also called short-circuits), which occur mostly as a result of insulation failure and sometimes due to external causes.

More information

Facility Connection Requirements

Facility Connection Requirements SEMINOLE ELECTRIC COOPERATIVE, INC. Facility Connection Requirements BULK ELECTRIC SYSTEM FACILITIES Facility Connection Requirements Page 1 of 19 Table of Contents 1. GENERAL CONNECTION REQUIREMENTS...

More information

Small Generator Interconnection System Impact Study Report. Completed For Q0047

Small Generator Interconnection System Impact Study Report. Completed For Q0047 Small Generator Interconnection Completed For Q0047 Proposed Interconnection PacifiCorp s Existing Goshen Rigby 69 kv Line March 7, 2005 1.0 Description of the Generation Facility Q0047 ( Interconnection

More information

CONFIRMATION OF VERIFICATION EVIDENCE REPORT (COVER) [Distribution Connected Generation (DCG)]

CONFIRMATION OF VERIFICATION EVIDENCE REPORT (COVER) [Distribution Connected Generation (DCG)] Project Name: Kitchener-Wilmot Hydro Inc. 301 Victoria Street South Kitchener, Ontario, Canada N2G 4L2 Appendix F2: Form DG06 CONFIRMATION OF VERIFICATION EVIDENCE REPORT (COVER) [Distribution Connected

More information

Instructions. Interconnection Customer declares its intention to interconnect with the AEP Distribution System.

Instructions. Interconnection Customer declares its intention to interconnect with the AEP Distribution System. APPLICATION FOR INTERCONNECTION WITH THE Indiana Michigan Power Company INDIANA DISTRIBUTION SYSTEM (Project capacity greater than 10kW) Instructions Interconnection Customer declares its intention to

More information

Power System Network Simulator (PSNsim)

Power System Network Simulator (PSNsim) The PSNsim is hardware simulator that simulates all parts of power system from generation to utilization. The PSNsim is a scaled down model of the real power system that provides an experimental environment

More information

COGENERATION INTERCONNECTION REQUIREMENTS. Parallel Operation of Connecting Parties Generation

COGENERATION INTERCONNECTION REQUIREMENTS. Parallel Operation of Connecting Parties Generation COGENERATION INTERCONNECTION REQUIREMENTS Parallel Operation of Connecting Parties Generation Cogeneration Interconnection Requirements (ID 195440).docx 1 (This page left blank intentionally) Cogeneration

More information

Revised Generation Interconnection Impact Study Report. For. Queue Position 31 ( Interconnection Customer )

Revised Generation Interconnection Impact Study Report. For. Queue Position 31 ( Interconnection Customer ) Revised Generation Interconnection Impact Study Report For Queue Position 31 ( Interconnection Customer ) September 22, 2004 1 Generation Interconnection System Impact Study Report I. Revision of Original

More information

GREAT RIVER ENERGY. May 2014 GREAT RIVER ENERGY

GREAT RIVER ENERGY. May 2014 GREAT RIVER ENERGY GREAT RIVER ENERGY GUIDELINES FOR TIE-LINE AND SUBSTATION INTERCONNECTIONS May 2014 GREAT RIVER ENERGY NOTE: Revision numbers were not formally tracked before June 2013 revisions; according to available

More information

Small Generator Interconnection Facilities Study Report. Completed for. ( Interconnection Customer ) Proposed Interconnection Pavant substation

Small Generator Interconnection Facilities Study Report. Completed for. ( Interconnection Customer ) Proposed Interconnection Pavant substation Small Generator Interconnection Facilities Study Report Completed for ( Interconnection Customer ) Proposed Interconnection Pavant substation Original report dated February 17, 2016 Revised March 11, 2016

More information

WECC Criterion MOD-(11 and 13)-WECC-CRT-1.1

WECC Criterion MOD-(11 and 13)-WECC-CRT-1.1 WECC Criterion MOD-(11 and 13)-WECC-CRT-1.1 A. Introduction 1. Title: Steady State and Dynamic Data Requirements 2. Number: MOD-(11 and 13)-WECC-CRT-1.1 3. Purpose: To establish the consistent data requirements

More information

Superseding SHEET NO. 34C-51 REVISED SHEET NO. 34C-51 Effective May 27, 2010 Effective December 3, 2011

Superseding SHEET NO. 34C-51 REVISED SHEET NO. 34C-51 Effective May 27, 2010 Effective December 3, 2011 Superseding SHEET NO. 34C-51 REVISED SHEET NO. 34C-51 INTERCONNECTION APPLICATION FOR ALL BUT UL1741 CERTIFIED INVERTER BASED SYSTEMS LESS THAN 10 KW In addition to the information provided below, a complete

More information

Disturbance Monitoring and

Disturbance Monitoring and PRC-002-2 R1 Notification Disturbance Monitoring and Reporting Requirements Compliance Spring Workshop May 10, 2017 Objectives This presentation will discuss: Requirement R1 Part 1.2 notifications Definition

More information

DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS

DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS STATE OF MINNESOTA DISTRIBUTED GENERATION INTERCONNECTION TABLE OF CONTENTS Foreword 2 1. Introduction 3 2. References 6 3. Types of Interconnections 7 4. Interconnection Issues and Technical Requirements

More information

Supervisory Control and Data Acquisition (SCADA) Performance Criteria Transmission Maintenance Procedure No. 6

Supervisory Control and Data Acquisition (SCADA) Performance Criteria Transmission Maintenance Procedure No. 6 Supervisory Control and Data Acquisition (SCADA) Performance Criteria Transmission Maintenance Procedure No. 6 Version 3 Effective Date 10/17/2017 Approved by: Transmission Maintenance Coordination Committee

More information

Midwest Energy, Inc. Distributed Generation Interconnection Expedited & Standard Process Application

Midwest Energy, Inc. Distributed Generation Interconnection Expedited & Standard Process Application Midwest Energy, Inc. Distributed Generation Interconnection Expedited & Standard Process Application Instructions To submit an application to interconnect a generating facility using the Expedited or Standard

More information

Small Hydro Regulatory and Permitting Requirements California

Small Hydro Regulatory and Permitting Requirements California Small Hydro Regulatory and Permitting Requirements California Lon W. House, Ph.D. 530.409.9702 Water & Energy Small Hydro Regulatory and Compliance FERC QF, Small Hydro License or Exemption EIA Generator

More information

APPENDIX B-1 TECHNICAL CONNECTION REQUIREMENTS. for GENERATION & INTERCONNECTION FACILITIES

APPENDIX B-1 TECHNICAL CONNECTION REQUIREMENTS. for GENERATION & INTERCONNECTION FACILITIES APPENDIX B-1 TECHNICAL CONNECTION REQUIREMENTS for GENERATION & INTERCONNECTION FACILITIES Revision: 4.0 12/28/2011 Page 1 of 40 DEFINITIONS TABLE OF CONTENTS A. Scope 1. Generation Connection and Operating

More information

SMALL GENERATING FACILITY PRE-APPLICATION REPORT REQUEST FORM

SMALL GENERATING FACILITY PRE-APPLICATION REPORT REQUEST FORM SMALL GENERATING FACILITY PRE-APPLICATION REPORT REQUEST FORM 1. Instructions By completing this request form, an Interconnection Customer may request a preapplication report from the NYISO regarding the

More information

LCRA Transmission Services Corporation. Facility Connection Requirements

LCRA Transmission Services Corporation. Facility Connection Requirements LCRA Transmission Services Corporation Facility Connection Requirements May 2018 Table of Contents 1.0 INTRODUCTION... 3 2.0 Facility Connection Requirements... 3 2.1 Summary of Basic Interconnection Requirements...

More information

LCRA Transmission Services Corporation. Facility Connection Requirements

LCRA Transmission Services Corporation. Facility Connection Requirements LCRA Transmission Services Corporation Facility Connection Requirements April 2017 Table of Contents 1.0 INTRODUCTION... 3 2.0 Facility Connection Requirements... 3 2.1 Summary of Basic Interconnection

More information

PRC Coordination of Protection Systems for Performance During Faults

PRC Coordination of Protection Systems for Performance During Faults PRC-027-1 Coordination of Protection Systems for Performance During Faults A. Introduction 1. Title: Coordination of Protection Systems for Performance During Faults 2. Number: PRC-027-1 3. Purpose: To

More information

WN U-60 Original Sheet No. 152

WN U-60 Original Sheet No. 152 WN U-60 Original Sheet No. 152 Table of Contents INTERCONNECTION WITH ELECTRIC GENERATORS 1) Introduction Sheet 152-A 2) Attachments Sheet 152-A 3) Definitions Sheet 152-B 4) Applicability Sheet 152-H

More information

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc Redundant Bus Protection Using High-Impedance Differential Relays Josh LaBlanc Purpose Discuss the configuration of the bus under study, and touch on the needs for redundant protection on the bus. Briefly

More information

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series Substation Automation Products Line distance protection REL670/650 Relion 670 and 650 series For maximum reliability of your power system REL670 and REL650 line distance protection IEDs (Intelligent Electronic

More information

BREAKER FAILURE PROTECTION

BREAKER FAILURE PROTECTION 0 th Annual HANDS-ON RELAY SCHOOL March 11-15, 201 REAKER FAILURE PROTECTION brent.c@relayapplication.com OUTLINE Protection System Failures and reaker Failures Protection versus Relaying Relay Schemes

More information

Generation Interconnection Impact Study Report. For. Interconnection Customer Q0022

Generation Interconnection Impact Study Report. For. Interconnection Customer Q0022 Generation Interconnection Impact Study Report For Interconnection Customer Q0022 Prepared by: PacifiCorp Date: 10/29/2003 Generation Interconnection System Impact Study Report Interconnection Customer

More information

CenterPoint Energy P O Box 1700 Houston, TX

CenterPoint Energy P O Box 1700 Houston, TX CenterPoint Energy P O Box 1700 Houston, TX 77251-1700 IF YOU ARE APPLYING FOR DISTRIBUTED GENERATION, PLEASE FOLLOW THE INSTRUCTIONS IN THE PARAGRAPHS BELOW. YOU WILL NEED TO COMPLETE AND SIGN AND THEN

More information

Standard Development Timeline

Standard Development Timeline Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Description of Current Draft

More information

PRC System Protection Coordination Supplementary Reference

PRC System Protection Coordination Supplementary Reference PRC-001-2 System Protection Coordination Supplementary Reference Contents: Disclaimer... 2 Generator Protection Devices or Elements that May Require Coordination with Transmission or Distribution Protective

More information

i-pcgrid Workshop 2014 PG&E Order No. 754 Analysis: Protection

i-pcgrid Workshop 2014 PG&E Order No. 754 Analysis: Protection i-pcgrid Workshop 2014 PG&E Order No. 754 Analysis: Protection 1 Process PG&E Order No. 754 Analysis Receive Bus List from Planning that Meet the Criteria in Table A Protection Computes Actual Clearing

More information

TECHNICAL REQUIREMENTS FOR INTERCONNECTION TO THE BLACK HILLS POWER TRANSMISSION SYSTEM

TECHNICAL REQUIREMENTS FOR INTERCONNECTION TO THE BLACK HILLS POWER TRANSMISSION SYSTEM TECHNICAL REQUIREMENTS FOR INTERCONNECTION TO THE BLACK HILLS POWER TRANSMISSION SYSTEM Version 1.2 May 28, 2009 Transmission Planning Department Revisions Rev. No. Date Description By Approval 1.0 8/10/06

More information

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY S&C Remote Supervisory V ista Outdoor Distribution (15.5 kv through 38 kv) Electric utility customers are increasingly concerned about the frequency and duration of outages they are experiencing, and are

More information

Branch Procedure. Document No. Issue No. : : 29/06/ /06/2021 (Supersedes CEOP8012, Generation Connection: Protection Guidelines, Issue 4.

Branch Procedure. Document No. Issue No. : : 29/06/ /06/2021 (Supersedes CEOP8012, Generation Connection: Protection Guidelines, Issue 4. Branch Procedure Document No. Issue No. : : CEOP8012 5 Approved By : Specialist Engineering NETWORK : Manager Approval Date Review Date : : 29/06/2018 29/06/2021 (Supersedes CEOP8012, Generation Connection:

More information

APPENDIX B-2. TECHNICAL CONNECTION REQUIREMENTS for LOAD DELIVERY FACILITIES. and SMALL GENERATION FACILITIES

APPENDIX B-2. TECHNICAL CONNECTION REQUIREMENTS for LOAD DELIVERY FACILITIES. and SMALL GENERATION FACILITIES APPENDIX B-2 TECHNICAL CONNECTION REQUIREMENTS for LOAD DELIVERY FACILITIES and SMALL GENERATION FACILITIES Revision: 4.0 12/30/2011 Page 1 of 39 TABLE OF CONTENTS DEFINITIONS A. Scope 1. Ownership 2.

More information

Interconnection Application

Interconnection Application Interconnection Application Member interested in applying for the interconnection of a distributed energy resource to the Utility s distribution system through the Fast Track or Study Processes are to

More information

TRANSMISSION FACILITIES INTERCONNECTION REQUIREMENTS

TRANSMISSION FACILITIES INTERCONNECTION REQUIREMENTS TRANSMISSION FACILITIES INTERCONNECTION REQUIREMENTS Corresponds to NERC Standard FAC-001-1 Developed By CPP Engineering Department May 1, 2015 Prepared by: Raymond O Neill, P.E. Version 3 INDEX CPP Transmission

More information

4.1.1 Generator Owner Transmission Owner that owns synchronous condenser(s)

4.1.1 Generator Owner Transmission Owner that owns synchronous condenser(s) A. Introduction 1. Title: Verification and Data Reporting of Generator Real and Reactive Power Capability and Synchronous Condenser Reactive Power Capability 2. Number: MOD-025-2 3. Purpose: To ensure

More information

January 22, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C.

January 22, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C. California Independent System Operator Corporation January 22, 2013 The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C. 20426 Re: California

More information

1. Coordination of series-rated devices is permitted where indicated on Drawings.

1. Coordination of series-rated devices is permitted where indicated on Drawings. SECTION 16055 - OVERCURRENT PROTECTIVE DEVICE COORDINATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

4.1.1 Generator Owner Transmission Owner that owns synchronous condenser(s)

4.1.1 Generator Owner Transmission Owner that owns synchronous condenser(s) A. Introduction 1. Title: Verification and Data Reporting of Generator Real and Reactive Power Capability and Synchronous Condenser Reactive Power Capability 2. Number: MOD-025-2 3. Purpose: To ensure

More information

Design of Coal Mine Power Supply Monitoring System

Design of Coal Mine Power Supply Monitoring System 2nd International Conference on Electronics, Network and Computer Engineering (ICENCE 2016) Design of Coal Mine Power Supply Monitoring System Lei Shi 1, Guo Jin 2 and Jun Xu 3 1 2 Department of electronic

More information

IMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO

IMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO IMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO PREPARED BY: System Management (WA) DOCUMENT REF: SO_OP_WA_3805 VERSION: 1.0 EFFECTIVE DATE: 13/10/2017 STATUS: DRAFT FOR CONSULTATION Approved

More information

ISO New England Data Modeling Requirements

ISO New England Data Modeling Requirements A U G U S T 1 5, 2 0 1 6 B O S T O N, M A ISO New England Data Modeling Requirements Renew Northeast Meeting Al McBride D I R E C T O R, T R A N S M I S S I O N S T R A T E G Y & S E R V I C E S Agenda

More information

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment TR No. 176002 1.1.EDITION April 1st, 2015 Nippon Telegraph and Telephone Corporation Introduction This document describes

More information

Supplemental Information

Supplemental Information Retirement of NPCC Directory# 3 Supplemental Information On April 1, 2015, NPCC Directory# 3 was retired upon the effective date of PRC-005-2 Protection System Maintenance which is subject to a 12 year

More information

Exelon Energy Delivery Interconnection Guidelines for Generators Greater than 2 MVA and Less than or equal to 20 MVA

Exelon Energy Delivery Interconnection Guidelines for Generators Greater than 2 MVA and Less than or equal to 20 MVA Exelon Energy Delivery Interconnection Guidelines for Generators Greater than 2 MVA and Less than or equal to 20 MVA Original 10-31-2006 1 Table of Contents DEFINITIONS...3 RESPONSIBILITIES OF THE GIC...5

More information

Advanced Protection and Control Technologies for T&D Grid Modernization

Advanced Protection and Control Technologies for T&D Grid Modernization Advanced Protection and Control Technologies for T&D Grid Modernization i-pcgrid Workshop San Francisco, CA March 31, 2016 Jeff Shiles, Principal Manager Protection & Automation Engineering Southern California

More information

Description of the Application Process for Small Embedded Generators

Description of the Application Process for Small Embedded Generators Description of the Application Process for Small Embedded Generators This document describes the Application Process for Small Embedded Generators (as required under section 5.3.3A of the National Electricity

More information

Christian PAYERL, Poznan, 20 th May, 2009 ABB FACTS Grid connection of Wind Farms. ABB Group May 22, 2009 Slide 1

Christian PAYERL, Poznan, 20 th May, 2009 ABB FACTS Grid connection of Wind Farms. ABB Group May 22, 2009 Slide 1 Christian PAYERL, Poznan, 20 th May, 2009 ABB FACTS Grid connection of Wind Farms May 22, 2009 Slide 1 FACTS Applications Flexible AC Transmission Systems May 22, 2009 Slide 4 System Studies - Grid Codes

More information

Attachment H: Small Generator (10 MW and Below) Technical Requirements and Standards

Attachment H: Small Generator (10 MW and Below) Technical Requirements and Standards Attachment H: Small Generator (10 MW and below) Technical Requirements and Standards Scope Attachment H: Small Generator (10 MW and Below) Technical Requirements and Standards The PJM Small Generator Interconnection

More information

Network Configuration Document Selection for New Substations Framework

Network Configuration Document Selection for New Substations Framework Network Configuration Document Selection for New Substations Current version: 20/06/2018 EXTERNAL USE Page 1 of 14 Table of contents 1. Introduction... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 References...

More information

Interconnection Feasibility Study Report GIP-IR377-FEAS-R1

Interconnection Feasibility Study Report GIP-IR377-FEAS-R1 Interconnection Feasibility Study Report GIP-IR377-FEAS-R1 Generator Interconnection Request 377 40 MW Wind Generating Facility Renfrew, NS Mar. 6, 2012 Control Centre Operations Nova Scotia Power Inc.

More information

IMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO

IMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO IMS INTERFACE MARKET PROCEDURE NETWORK OPERATORS AND AEMO PREPARED BY: System Management (WA) DOCUMENT REF: SO_OP_WA_3805 VERSION: 1.0 EFFECTIVE DATE: 13/10/2017 STATUS: FINAL Approved for distribution

More information

JEA Facility Interconnection Requirements

JEA Facility Interconnection Requirements JEA Facility Interconnection Requirements Developed in response to NERC FAC-001-2 and associated recommendations Revision 4.0 Dec 15, 2017 Page 1 of 22 1. Table of Contents 1. Introduction:... 3 2. Application

More information

Demonstration Test Bed for Advanced Control Systems

Demonstration Test Bed for Advanced Control Systems Demonstration Test Bed for Advanced Control Systems Christopher R Clarke Senior Engineer SCE Advanced Technology June 22, 2016 1 Advanced Distribution Control Systems Introduction of customer adoption

More information

Operations ISO Version: 1.6. Effective Date: 8/02/2018. Fieldwork Guide. Fieldwork Guide

Operations ISO Version: 1.6. Effective Date: 8/02/2018. Fieldwork Guide. Fieldwork Guide REVISION HISTORY VERSION NO. (Must match header) DATE REVISED BY DESCRIPTION 1.0 6/6/2016 EDAS Created Document 1.1 6/29/2016 EDAS Updates to include all Meter Work and instruction 1.2 8/29/2016 EDAS Included

More information

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series Substation Automation Products Generator protection REG670/650 Relion 670 and 650 series A new protection standard for your valuable assets Based on ABB s extensive experience, REG670 and REG650 IEDs (Intelligent

More information

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements Introduction to Bus Protection By Matt Horvath, P.E. November 6, 2018 Electrical Buses Physical and Electrical Junction A bus is a critical element of a power system, as it is the point of convergence

More information

CHAPTER 11 HOW TO ENHANCE THE RELIABILITY & POWER QUALITY OF ELECTRICITY SUPPLY

CHAPTER 11 HOW TO ENHANCE THE RELIABILITY & POWER QUALITY OF ELECTRICITY SUPPLY CHAPTER 11 HOW TO ENHANCE THE RELIABILITY & POWER QUALITY OF ELECTRICITY SUPPLY CHAPTER 11 HOW TO ENHANCE THE RELIABILITY & POWER QUALITY OF ELECTRICITY SUPPLY 11.1 Introduction 1. HK Electric provides

More information

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Power Systems Communications Implementation of IEC61850 in a Substation Environment Power Systems Communications Implementation of IEC61850 in a Substation Environment 26 October 2009 Reference VEE4700-01 Revision 0 Document Control Document ID: DOCUMENT1 Rev No Date Revision Details

More information

PG&E 500 kv Protection Standard Design and Development

PG&E 500 kv Protection Standard Design and Development PG&E 500 kv Protection Standard Design and Development Davis Erwin, Rafael Pineda, and Monica Anderson Pacific Gas and Electric Company Eric Udren Quanta Technology, LLC Jordan Bell and Neal Jones Schweitzer

More information