NN1 PH1 CC1 DM1 DB1. TABLE V - Options. Mounting Hardware. Instruction Books NN2 PH2 CC2 DM2 DB2. Certificates. PID Control NN C3.
|
|
- Kerry Harmon
- 5 years ago
- Views:
Transcription
1 0---0 January 00 Quick Start Guide for UDA Universal Dual Analyzer For detailed instructions see UDA Universal Dual Analyzer Product Manual Step. Model Number Interpretation Write your analyzer model number in the boxes. Then refer to Tables I, II, III, IV, and V, and circle the corresponding options to identify your analyzer s features. A dot indicates the feature is available. _ Key Number Table I II III IV V Key Number - Dual Input Analyzer Stock Part No. Selection Availability Analytical Analyzer UDA TABLE I - Channel Inputs Channel Input TABLE II - Channel Inputs Channel Input None ph/orp Conductivity Dissolved Oxygen ppm Dissolved Oxygen ppb None ph/orp Conductivity Dissolved Oxygen ppm Dissolved Oxygen ppb NN PH CC DM DB NN PH CC DM DB TABLE IV - Communications None Communications Modbus RTU (RS-) (Future Release) TABLE V - Options Mounting Hardware Instruction Books Certificates PID Control None (Panel mounting only) Pipe and wall mounting hardware CD Only (English) Additional Paper Copy: English None Calibration & Conformance No Yes Stock Part No Selection Availability N M 0 _ P 0 _ E 0 _ C 0 _ C TABLE III - Outputs and Relays Additional Analog Output & Relays No Additional Analog Output or Relays Additional -0 ma/0-0 ma output & additional relays -0 NN C Step. Panel Mounting Dimensions Step. Wiring Diagrams + -0 [.0] Panel Cutout + -0 [.0] WARNING Qualified personnel should perform wiring only. A disconnect switch must be installed to break all current carrying conductors. Turn off power before working on conductors. Failure to observe this precaution may result in serious personal injury. An external disconnect switch is required for any hazardous voltage connections to the relay outputs. Customer will need to provide a rear panel support plate to maintain NEMA protection if primary panel thickness is less that.mm [0.0 ] thick. [.] [.] [.] CUSTOMER PANEL.[.0] to. MAX[0.] [.] Durafet III Cable shield (yellow) Green Green with Black stripe Blue Black 0 R KO res- (Low) R KO res- (High) Drain Substrate ()M machine screws w/lockwashers supplied with unit Do not over ().[.] holes for tighten screws lead wires and conduit fittings. Nm(0 Lb-in) (conduit fittings supplied by user) of torque max. The analyzer can be mounted Vertically or Horizontally on a pipe. Use the bracket and hardware supplied in the mounting kit. The analyzer can be mounted on a wall. Use the bracket and hardware supplied in the mounting kit. with Black stripe with Black stripe with Black stripe Black with stripe Blue with Black stripe Counter RTH rd EEGND EEDATA Remove pre-wired jumper at terminals & Each unit has ().mm[."] dia. holes on the bottom of the unit for lead wires and conduit fittings. The user supplies the conduit fittings. ATTENTION - When installing the unit, you must select fittings that are agency approved (UL/CSA) to insure NEMA integrity Page of
2 0---0 January 00 Quick Start Guide for UDA Universal Dual Analyzer Step. Wiring Diagrams, continued Durafet II Glass Meredian II Cable shield (yellow) Green Green with Black stripe Blue Black 0 R KO res- (Low) R KO res- (High) Drain Substrate with Black stripe with Black stripe with Black stripe Counter RTH rd Remove pre-wired jumper at terminals & with Black stripe Clear (center conductor of coax) Jumper 0 Guard Glass (or ORP) ORP HPW000 Shield Clear (center conductor of coax) 0 Guard Glass (or ORP) cable shield ( with Green stripe) cable Clear (center conductor of coax) Measurement cable shield Measurement with Black stripe ( with Green stripe) cable Clear (center conductor of coax) to chassis ground screw Thermistor Jumper cable Black Thermistor cable shield ( with Green stripe) 0 Guard Glass (or ORP) Counter RTH rd Page of
3 0---0 January 00 Quick Start Guide for UDA Universal Dual Analyzer Step. Wiring Diagrams (continued) Dissolved Oxygen Cable shield (Blue) Clear Green with Black stripe Yellow to chassis ground screw 0 Cathode Anode Guard Earth Ground Refer to the Product Manual 0--- for connecting and disconnecting sequences Conductivity Cond. AWG (Has no shield) name Black 0 Cell Low Green to chassis ground screw Cell High RTH rd Earth Ground Power Supply and Outputs Wiring Diagrams Power Supply/Analog Output/Relay Output Card Option Card WARNING Turn power off at mains before installing AC Power Wiring. WARNING The ground terminal must be connected to a reliable earth ground for proper operation and to comply with OSHA and other safety codes If metal conduit is used, connect a bonding wire between conduits. Do not rely upon the conductive coating of the instrument case to provide this connection. Failure to observe this precaution may result in serious personal injury. Analog Output (+) Analog Output ( ) Analog Output (+) Analog Output ( ) Relay Output (N.O.) Relay Output (COM) Relay Output (N.C.) Relay Output (N.O.) Relay Output (COM) Relay Output (N.C.) AC Hot L AC N L 0 Remove the Jumper if you are using an Analog Output Terminal Analog Output (+) Analog Output ( ) Case (earth) Ground Digital Input (+)* Digital Input ( )* Digital Input (+)* Digital Input ( )* Case (earth) Ground Relay Output (N.O.) Relay Output (COM) Relay Output (N.C.) Relay Output (N.O.) Relay Output (COM) Relay Output (N.C.) Case (earth) Ground 0 * Contact Closure only Grounding Stud on Case Page of
4 0---0 January 00 Step. Key Navigation and Display Key Quick Start Guide for UDA Universal Dual Analyzer Function Display Hold Setup When process values are on display: Use DISPLAY to cycle between PV Displays, Control Displays, and Status Displays. In Setup mode, calibration mode, or calibration edit mode, use DISPLAY to abort current mode and return to the last accessed online display. Engages hold of analog and digital outputs at their current values and any relays assigned to alarm events or control are deactivated. Selects the configuration main menu when online, in calibration mode, or at a calibration submenu. Exit Calibrate In configuration menu, exits submenu to parent menu. If at configuration main menu, selects current online display. In configuration edit mode, aborts editing of current parameter. When online, it acknowledges current alarm event to stop the flashing of the relay indicator and status message area. Selects the calibration main screen when online, in configuration mode or at another calibration screen. When a Setup configuration menu or configuration edit screen is on display: Use Up/Down keys to highlight a different item. In configuration edit mode, it either selects the parameter character or numerical digit to change or selects an enumerated parameter value: Use Up/Down key to increment the value of the digit at the cursor. Increases/decreases the selected parameter value. When in display mode, use up/down keys to adjust the contrast on the screen. In configuration edit mode, selects the character or digit to change. In calibration mode, it selects the next or previous calibration screen. In Display mode, It selects a single or dual display on a unit with dual input. Enter In configuration menu, selects edit mode for selected parameter. In configuration edit mode, saves edited parameter selection or value. In calibration mode, selects parameters to reset and the next calibration screen Two Input Display Press Display. You will see: PV Value Tag PV Units PV Temperature Relay Physical State De-energized Black - Energized Solution Temperature Compensation PV Output Bargraph* Output Bargraph* Solution Temperature Compensation PV Relay Physical State De-energized Black - Energized UDA.00 C H NO NaCl ph.0 µs/cm ºC 0.0 ºC Probe PV Fault PV Value Diagnostics or Alarm Message Relay Physical State De-energized Black - Energized Output Bargraph* Relay Physical State De-energized Black - Energized *On the display, the bargraphs are the outputs in Engineering Units, the corner annunciators are the physical relay states. Single Displays For single displays on a two input unit, Press to display a single display for Input. Press again to display a single display for Input. Press again to return to a Dual Display. Page of
5 0---0 January 00 Step. Basic Configuration Procedure Quick Start Guide for UDA Universal Dual Analyzer Step Operation Press Result Enter Set Up Mode Setup The Main Menu is displayed. Use to scroll and select a setup group (Example Inputs). The selection will be highlighted. Enter Set Up Group Enter Enter the selection Enter Change the Value or Selection Enter The Setup group selected is shown at the top of the screen and will display all the selections within that group. Press to highlight the desired selection. The list of parameters for the selection will be displayed. Press to highlight the desired selection. The current value for the parameter is displayed. Depending on whether you are changing a text string or a numerical value, follow the General Rules for Editing in section.. of the manual to make the changes Enter the Value or Selection To Abort the Changes Made Exit Setup Mode Enter Exit Exit Enters value or selection made into memory after another key is pressed. Repeat the procedure for changing any parameter for any group. Any changes made to a parameter value will revert to the original value before editing. Until you see the main Setup screen. Step. Configuration Record Sheet Enter the value or selection for each prompt on this sheet so you will have a record of how your controller was configured. Sub-menu Parameter Selection or Range of Setting User Selection Inputs Configuration Input or ph/orp PV Type Range PV Reset Temp Input (ORP only) Temp Type Temp Value Solu Temp Comp (Not ORP) ph Glass; ph HPW; ph Durafet; or ORP Off; Enable - Resets all Output and Control ranges associated with that PV to allow Temp Type selection 0Ω Thermistor; 000Ω Resistance Temperature Detector; or Manual -0.0 to 0.0ºC or.0 to 0.0ºF (Value for Manual selection at Temp Type) See Maintenance set up group for units selection None; Custom; H 0; NH ; PO ; or C H NO Solution ph/ C (Not ORP) (Solu Temp Comp = Custom) to Bias - to Failsafe - to Filter Time 0 to 0 Input or Input Conductivity PV Type Cell Constant 0.0; 0.;.0; 0.0;.0; or 0.0 Conduc µs; Conduc ms; Concentratn; TDS ppb; TDS ppm; TDS ppt; or Resistivity (Availability dependant on Cell Constant selection) Range PV Reset Off; Enable - Resets all Output and Control ranges associated with that PV Cal Factor 0.0 to.0 TDS Factor (only PV Type TDS) 0.0;.000; or.000 Temp Type Temp Value Solu Temp Comp Len Units Len Feet 0Ω Therm; 000Ω RTD; Manual -0.0 to 0.0ºC or.0 to 0.0ºF (Value for Manual selection at Temp Type) See Maintenance set up group for units selection None; Custom; H 0; NH ; PO ; C H NO; HCl; NaCl; H SO ; or NaOH Feet or Meters 0 to 000 ft Len Meters 0 to 0.0 Size Units Size AWG AWG or Sq mm AWG; AWG; 0 AWG; or AWG Size Sq mm 0. to.0 Bias -.00 to.00 Failsafe 0.0 to 000 Page of
6 0---0 January 00 Quick Start Guide for UDA Universal Dual Analyzer Sub-menu Parameter Selection or Range of Setting User Selection Filter Time 0 to 0 Input or Input Dissolved Oxygen PV Type Range PV Reset Temp Type Temp Value Salinity Type Salinity ppt Pressure Type Pressure mm Hg Pct Sat - percent saturation; DO Concentration Off; Enable - Resets all Output and Control ranges associated with that PV 000Ω Therm; 000Ω RTD; Manual -0.0 to 0.0ºC or.0 to 0.0ºF (Value for Manual selection at Temp Type) See Maintenance set up group for units selection Manual; Conduc Input 0.00 to 0.00ppt ( Manual Salinity type only) Manual; Sensor 00.0 to 00.0 (Manual Pressure type only) Outputs Configuration Output Output Output Relays Configuration Relay Types Digital Output Relay Bias Failsafe Filter time 0 to to 0.00 PPM (If PPM board installed) to 000 PPB (If PPB board installed) to 0.00 PPM (If PPM board installed) to 000 PPB (If PPB board installed) None; Input PV; Input Temp; Input PV; or Input Temp; Math ; Math ; Math ; Math ; Control ; Control High Range -.00 to.00 Low Range -.00 to.00 Slew Time to.00 ma Range High 0 to 0 ma Range Low 0 to 0 ma Limit High 0 to ma Limit Low 0 to Relay Type, Relay Type, Relay Type, Relay Type Digital Output Relay; Time Proportional Output Relay; Pulse Frequency Output Relay Digital None; Alarms thru ; Four Control Alarms; Logic thru ; Events thru ; Math thru Invert Enable or Disable TPO - Time Proportional Output High Range - to None; Input PV; Input Temp; Input PV; or Input Temp; Math thru ; Control and Low Range - to Cycle Time to seconds Min Off Time 0 to Min On Time 0 to Pulse Frequency Output High Range - to None; Input PV; Input Temp; Input PV; or Input Temp; Math thru ; Control and Low Range - to Cycle Time to seconds Page of
7 0---0 January 00 Quick Start Guide for UDA Universal Dual Analyzer Sub-menu Parameter Selection or Range of Setting User Selection Alarms Configuration Alarm ; Alarm ; Alarm Alarm Math Configuration Math ; Math ; Math ; Math Logic Configuration Logic ; Logic ; Logic ; Logic Control Configuration Type (alarm action) None; Input PV; Input Temp; Input PV; or Input Temp; Calc Value ; Calc Value None; High; Low Setpoint Value 0 to. Latch Alm Hysteresis 0.0 to. % On Delay 0 to seconds Event None; Event ; Event ; Event ; Event Type None; Input PV; Input Temp; Input PV; or Input Temp None; Linear; Log; Square Root High Range - to Low Range - to Filter Time 0 to 0 seconds IN A None; Alarm thru ; Four Control Alarms; Digital Input ; Digital Input ; Hold; Out Fault; Out Fault; Out Fault IN B None; Alarm thru ; Four Control Alarms; Digital Input ; Digital Input ; Hold; Out Fault; Out Fault; Out Fault Type Invert Latch On delay None; AND; OR None; IN A; IN B; or In A and B Enable; Disable 0 to seconds Event None; Event thru Control Types Control or Control Type None; PID(option); On/Off (standard) PID (optional) PV High - to PV Low - to SP High Limit - to SP Low Limit - to Control Alg Control Action Accutune Fuzzy Logic Use Prop Band Use RPM PIDA; PIDB; Duplex A; Duplex B Direct; Reverse Gain or PB Gain 0.% to 000.0%; PB 0. to 000.0% Rate -0.0 to Reset -0.0 to 0 Tune Set Gain or PB Gain 0.% to 000.0%; PB 0. to 000.0% Rate -0.0 to Reset -0.0 to 0 Out High Limit -.00 to 0.0% Out Low Limit -.00 to 0.0% Power Mode Power Out Last; Manual Failsafe; Last Failsafe -.00 to 0.0% Alm SP Type Alm SP Value - to Page of
8 0---0 January 00 On/Off Quick Start Guide for UDA Universal Dual Analyzer Sub-menu Parameter Selection or Range of Setting User Selection Alm SP Type Alm SP Value - to Alm SP Type Alm SP Value - to Alm SP Type Alm SP Value - to Alm Hysteresis 0 to 00% PV High - to PV Low - to SP High Limit - to SP Low Limit - to Control Action Direct; Reverse Out High Limit -.00 to 0.0% Out Low Limit -.00 to 0.0% Out Hysteresis -.00 to 0.0% Power Mode Power Out Last; Manual Failsafe; Last Failsafe -.00 to 0.0% Alm SP Type Alm SP Value - to Alm SP Type Alm SP Value - to Alm SP Type Alm SP Value - to Alm SP Type Communication Configuration Alm SP Value - to Alm Hysteresis 0 to 00% Mode Address; Setup Address 0 to Reset Maintenance Configuration Off; On SW Version Input and Input Type Language Tag Password Temperature Units Mains Frequency Display Test Keypad Test Output Level Relay State Unit Reset English; Italiano; Deutsch; Francais; Espanol 0 to Characters 0000 to or AAAA to ZZZZ º C; º F 0 Hz; 0 Hz Off; Enable Off; Enable Off; 0%; %; 0%; %; 00%; Low Limit; High Limit Off; Energized; De-energized Off; Enable Page of
Description, continued
DL424/425 DirectLine Sensor Module for DL5000 Dissolved Oxygen Probes Overview 70-82-03-48 4/02 Page of 8 Specification The DirectLine DL424/425 Sensor Modules are part of a family of products developed
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationCDD Carbon Dioxide Transmitter
Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate
More information+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions
GF SIGNET 8850 Conductivity/Resistivity Transmitter Instructions ENGLISH 8850.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to
More information+GF+ SIGNET ph/orp Transmitter Instructions
GF SIGNET 8750 ph/orp Transmitter Instructions ENGLISH 8750.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
More informationThermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet
English ph / ISE / COND / RDO / DO Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the
More informationCDD4 Series Room CO2 Transmitter Installation Instructions
CDD4 Series Room CO2 Transmitter Installation Instructions Introduction The CO2 transmitter uses Infrared Technology to monitor CO2 levels and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. Options include
More informationUDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and
More informationAnalyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK
Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL
More informationTABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)
Issue 11 Page 1 of 5 Model Selection Guide Instructions Consult Steps to Selecting Appropriate Conductivity Instrumentation and Cells before making selections below. Select the desired key number. The
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationControlMaster CM10, CM30 and CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN
User Guide Basic Functionality IM/CM/B EN Rev. Q ControlMaster CM10, CM30 and CM50 The Company We are an established world force in the design and manufacture of instrumentation for industrial process
More informationIso DIN. User Manual. 1 channel Earth Fault Monitoring
Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee
More informationRange. Body Material. Max. Press ms K=0, C 4 bar Glass Graphite 13.5 PG Full integrated 5-meter cable
Conductivity Range Conductivity 0 20 μs; 0 200 μs; 0 2.000 μs; 0 20.000 μs; 0 200.000 μs Resolution 0,01 μs; 0,1 μs; 1 μs; μs Avaiable versions with double parameter 4238-22 [ph/orp - Conductivity] 4293-22
More informationControlMaster CM10, CM30 and CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN
User Guide Basic Functionality IM/CM/B-EN ControlMaster CM10, CM30 and CM50 The Company We are an established world force in the design and manufacture of instrumentation for industrial process control,
More informationFLS M9.06 PH/ORP MONITOR. safety instructions. packing List
FLS M9.06 PH/ORP MONITOR safety instructions General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other instruments
More informationSignet ph/orp Transmitter * *
Loop 7 6 5 Signet 8750- ph/orp *-8750.090-* CAUTION! Contents 0.0 ph 5.0C Signet ph/orp. Installation. Panel Installation gasket panel terminals mounting bracket 96 mm (.8 in.) 8050 8 mm (. in.) Optional
More informationSimplified information where and how you want it.
ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More informationOmni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY
Omni Economic Self-Tune PID Temperature Controller Omni 7 Omni 4 6 5 4 3 1 7X7 7 1 11 5 ~ 65 V AC SUPPLY Omni 6 CONTENTS 1. PANEL MOUNTING & ELECTRICAL CONNECTIONS 1. FRONT PANEL : LAYOUT AND OPERATION
More informationTable of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION
Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationUser Guide IM/AX4PH Rev. N. AX416, AX436, AX460, AX466 & AX468 Single and dual input analyzers for ph/redox (ORP)
User Guide IM/AX4PH Rev. N Single and dual input analyzers for ph/redox (ORP) The Company We are an established world force in the design and manufacture of measurement products for industrial process
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow
More informationLAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationModel T28 Transmitter
Model T28 Transmitter Product Training Presented by: Joe Bradley October 2009 ELECTRO-CHEMICAL DEVICES Model T28 Transmitter Two Wire Transmitter Loop Powered 24 VDC @ 500 Ω Measurement Choices ph ORP
More informationContents. 1. Installation
ENGLISH 8750.090 C/0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation. Specifications. Electrical
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationFLS M9.06. ph/orp MONITOR
FLS M9.06 /ORP MONITOR Safety Instructions General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other instruments
More informationSHARK MULTI-PARAMETER CONTROLLER & ANALYZER USER S MANUAL
SHARK MULTI-PARAMETER CONTROLLER & ANALYZER USER S MANUAL Rev 3 AquaMetrix Inc. 1245 Maple Hill Ct., Unit 7 Newmarket, ON Canada, L3Y 9E8 Tel: (800) 742-1413 (905) 954-0841 Fax: (905) 954-0415 www.aquametrix.com
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff
More informationCarbon Monoxide (CO) Gas Detection and Control System
Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature
More informationOperation Manual. Transmitter M300
Operation Manual Transmitter M300 ph/redox, Dissolved Oxygen, Conductivity/Resistivity, Dissolved Ozone, single channel version Cond/Cond dual channel version Multiparameter dual channel version for analog
More informationCX3100 Intelligent Conductivity Transmitter
CX3100 Intelligent Conductivity Transmitter Operation Manual CX3100 CONTENTS Precautions for Installation Brief Instruction 1 1. Specifications 4 2. Assembly and Installation 2.1 Transmitter Installation
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter
ABB MEASUREMENT & ANALYTICS DATA SHEET TB84PH ph /ORP / pion transmitter 2 TB 8 4PH P H /ORP / P I ON TR AN S MIT TE R DS/ TB8 4PH-E N RE V. D Measurement made easy Hazardous area rated transmitter with
More informationInstruction Sheet PN 51A-6081C/rev.A June Model 6081-C Wireless Contacting Conductivity Transmitter
Instruction Sheet PN 51A-6081C/rev.A June 2009 Model 6081-C Wireless Contacting Conductivity Transmitter ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures,
More information770MAX Multiparameter Analyzer/Transmitter. Instruction Manual
THORNTON Leading Pure Water Analytics Part No. 84372 770MAX Multiparameter Analyzer/Transmitter Instruction Manual IMPORTANT SAFETY INFORMATION Follow all warnings, cautions, and instructions indicated
More informationT80 Universal Transmitter S80 Intelligent Sensors
T80 Universal Transmitter S80 Intelligent Sensors Presented by: January 2012 ELECTRO-CHEMICAL DEVICES T80 Universal Transmitter One Transmitter for Multiple Measurements ph ORP Dissolved Oxygen All Specific
More informationBXD17 Series. Features. Analytical instrumentation for your measurement applications.
BXD17 Series Analytical instrumentation for your measurement applications. Features Single parameter instrument with temperature measurement capabilities Custom IP66 NEMA 4X (144 x 144mm) enclosure Versatile
More informationProcess & Temperature Digital Panel Meter
Process & Temperature Digital Panel Meter TRIDENT PD765 4-20 ma, ± 10 V, TC & RTD Inputs NEMA 4X, IP65 Front Shallow Depth Case 3.6" Behind Panel Universal Power Supply 85-265 VAC Two Relays Option with
More informationMiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities
MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs
More informationHIGH-VOLTAGE DC METER
HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationM260 Load Cell Amplifiers
E L 4 - + 2-3 1-2 M260 Load Cell Amplifiers Description. This fast start guide shows basic installation, setup, and calibration for most applications. For more specific information contact Minsterport.
More informationNavigator 540. Measurement made easy. Introduction. For more information
ABB MEASUREMENT & ANALYTICS INSTRUCTION MANUAL CI/AWT540-EN REV. C Navigator 540 Transmitter Measurement made easy Navigator 540 transmitter Introduction This publication provides commissioning instructions
More informationM A C 3 Wind Speed Alarm & Controller
M A C 3 Wind Speed Alarm & Controller Installation Instructions Thank you for purchasing the MAC3 wind speed alarm and controller. This manual is designed to lead you through a step-by-step process to
More informationSIGNET 5700 ph/orp Monitor - ORP Instructions
SIGNET 5700 ph/orp Monitor ORP Instructions ENGLISH 35700.0901 H (6/01) English CAUTION! Refer to instruction manual for more details. Remove power to unit before wiring input and output connections. Follow
More informationHydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller
HydroGuard 4 to 20 ma Output Module For use with HydroGuard Water Quality Monitor and Controller Technician's Manual Installation, Operation, and Maintenance Guide Chapter 1: Preface... 3 1.1 Intended
More informationLevel instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview
Overview The is a universal input, panel mount remote digital display for process instrumentation. Benefits Easy setup and programming via front panel buttons or remotely using RD software Display readable
More informationHigh Voltage DC Meter
High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount NEW! Modbus Module supports RS485 Serial Modbus Communications Multiple sensor types supported with
More information2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...
TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...
More informationWall-/Pipe Mounted Universal Process Indicator
Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationTable of Contents. 1 Introduction Introduction Front Panel Description Rear Panel Description 3
Chapter Page 1 Introduction 1 1.1 Introduction 1 1.2 Front Panel Description 2 1.3 Rear Panel Description 3 Table of Contents 2 Installation and Operation 4 2.1 Mounting Instructions 4 2.2 Power Connections
More informationSIGNET ph/orp Transmitter
SIGNET 8750- ph/orp Transmitter ENGLISH 3-8750.090- D-4/03 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.
More informationFLOW MONITOR & TRANSMITTER
FLS M9.02 FLOW MONITOR & TRANSMITTER SAFETY INSTRUCTIONS General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other
More informationMODCELL 2050R Single Loop Controllers
Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile
More informationTB84TE Conductivity transmitter 2-Electrode. Superior accuracy in low conductivity and pure water. applications
Data sheet DS/TB84TE EN Rev. C TB84TE Conductivity transmitter 2-Electrode Superior accuracy in low conductivity and pure water applications Smart key menu programming Superior accuracy in low conductivity
More informationdual-line 6-dIGIt process MeteR
dual-line 6-dIGIt process MeteR ProVu Se r i e S provu Model pd6000 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC or 12/24 VDC Input Power Large Dual-Line 6-Digit
More informationIPM500 Series QuickStart Manual
IPM500 Series QuickStart Manual The Force of Innovation 10 Thomas Irvine, CA 92618 USA (949) 465-0900 FAX: (949) 465-0905 E-Mail: HTUfutek@futek.comUTH www.futek.com Manufacturer of Load Cells, Pressure
More informationThermo Scientific AquaPro Multi-Input Intelligent Process Analyzer
Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer Thermo Scientific AquaPro provides accurate, user-friendly in-line monitoring of process applications from power generation to municipal
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More information3690 N.W. 53rd Street Fort Lauderdale, FL SC-2124 SC-2124M. 24 Channel Universal Scanner. Installation and Operation Manual P/N 145F-11902
3690 N.W. 53rd Street Fort Lauderdale, FL 33309 SC-2124 SC-2124M 24 Channel Universal Scanner Installation and Operation Manual P/N 145F-11902 Rev. 3.30 (c) Copyright 2000, Dynalco Controls All Rights
More informationOmni + User Manual. Dual Setpoint Temperature Controller with Programmable Input & TIMER. Omni 96+ Omni 72+ Omni 48+ TMR TMR TMR
Omni + Dual Setpoint Temperature Controller with Programmable Input & TIMER Omni 72+ Omni 48+ TMR TMR Omni 96+ TMR CONTENTS 1. PANEL MOUNTING & ELECTRICAL CONNECTIONS 1 2. FRONT PANEL : LAYOUT AND OPERATION
More informationSafety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input
Safety 1. Installation 1.1 PT:Services 1.2 erature Compensation of 1.3 Controller Services 1.4 Driver Card Installation 1.5 Sensor Part Numbers 1.6 Sensor Wiring 2. Configuration - Operation 2.1 Selection
More informationConductivity Transmitters
Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows
More informationDigital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free
Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard
More informationMAC3 Wind Speed Alarm & Controller. Installation Instructions
MAC3 Wind Speed Alarm & Controller Installation Instructions Table of Contents Overview... 3 Installation... 3 Optional Equipment... 10 Dual Sensor Operation... 10 Other Optional Equipment... 10 Operation
More informationC160 Wall-/Pipe Mounted Universal Process Indicator
Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement
More information+GF+ SIGNET 9050CR Conductivity/Resistivity Controller
+GF+ SIGNET 9050CR Conductivity/Resistivity Controller Instruction Manual GEORGE FISCHER +GF+ Important Safety Information! CAUTION: Remove AC power to unit prior to wiring input and output connections.
More information+GF+ SIGNET 5800CR Conductivity/Resistivity Monitor Instructions
GF SIGNET 5800CR Conductivity/Resistivity Monitor Instructions ENGLISH 35800CR.0901 D1/98 CAUTION! Refer to instruction manual for more details. Remove power to unit before wiring input and output connections.
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationThermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter
English Cond Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket
More informationOZONE SWITCH Model OS-6. OS-6 Features
USER MANUAL OZONE SWITCH Model OS-6 OS-6 Features The OS-6 is an industrial grade ozone controller and monitor. The OS-6 design is optimized for accuracy and ease of installation, setup and operation.
More informationIndustrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4
Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories
More informationSignet Pressure Transmitter
Signet 850 Pressure English *850.090* 850.090 Rev. H /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationPD Large Display Feet & Inches Process Meter. Feet & Inches process. Actual Size Digit
PD2-6001 Large Display Feet & Inches Process Meter Actual Size Digit Feet & Inches process Feet & Inches Display Ideal for Level Applications Large 1.80ꞌꞌ Dual-Line 6-Digit Display Readable from up to
More informationE:COUNT LT MODEL MCR-09 SPECIFICATIONS & INSTALLATION REFERENCE
Mounting: The E:Count LT uses a four bolt (1/4-20) mounting pattern on the foot of the unit. If the unit is to be mounted directly to the flowmeter and uses the internal pulser the appropriate mounting
More informationACCESS 9340/9360 Meter Input/Output Module
Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the
More informationThermo Scientific Orion Star A325 Portable ph/conductivity Meter. Instruction Sheet
English ph / COND Thermo Scientific Orion Star A325 Portable ph/conductivity Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket plug
More informationPart No pH/CR ph, ORP, Conductivity & Resistivity Instrument Instruction Manual
Part No. 84383 200pH/CR ph, ORP, Conductivity & Resistivity Instrument Instruction Manual SAFETY INFORMATION INSTALLATION: This instrument must be installed by trained instrumentation personnel in accordance
More informationPump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters
DESCRIPTION Pump-Down Controller Input Scalable Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters The Model 4052 Pump-Down Controller provides total control for duplex pumping
More informationOPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS
OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating
More informationMulti-input transmitter
ABB MEASUREMENT & ANALYTICS MISSIONING INSTRUCTIONS CI/AWT440-EN REV. A Aztec AWT440 Multi-input transmitter Measurement made easy Aztec AWT440 multiinput transmitter Introduction The Aztec AWT440 is a
More informationMYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL
MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING
More information5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.
5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)
More informationLAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER
LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER The Model 1575e uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics
More informationGlobal Water globalw.com. Global Water. Instrumentation, Inc.
Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com PC300: Process Controller
More informationOPERATION MANUAL MODEL TT-LP
TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors
More information1. Installation. 2. Configuration - Operation. 3. Specifications. Safety
Safety 1. Installation 1.1 OP_ext: Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring 1.5 Controller Wiring 2. Configuration - Operation 2.1 Replaces ph Sensor 2.2 AS -Flex Series
More informationInstruction Manual. Model US1000 Digital Indicating Controller. IM 5D1A01-01E 3rd Edition IM 5D1A01-01E
Instruction Manual Model US1000 Digital Indicating Controller 3rd Edition Introduction This instruction manual describes the general operation of the US1000 Digital Indicating Controller. Intended Readers
More informationLarge DIspLay process Meters
Large DIspLay process Meters Model pd650 NeMa 4X 2.3" High LeD Model pd655 NeMa 4X 1.0" High LeD Model pd656 exp-proof 4X 0.8" High LeD 4-20 ma, 1-5 V, 0-5 V, 0-10 V inputs 4½ digit + extra zero display
More informationMicroprocessor ph/orp Controller
PC3030A/PC-3050 Microprocessor ph/orp Controller Operating Manual CONTENTS 1 Specifications... 2 Assembly and installation... 2.1 Precautions for installation.. 2.2 Install the controller on the wall mount
More informationMODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system
More informationSINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series
The Digitec Series D3800 Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. The D3820 and D3830 are available in the ranges of 4-20mA, 0-10 VDC,
More informationModel No Universal Input Indicator Start-up Guide
Model No. 1480 Universal Input Indicator Start-up Guide Contents 1. Setting up a unit straight out of the box... 3 1.1. Entry into Configuration mode... 3 1.2. Scrolling through Parameters and s... 3 1.3.
More informationPGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.
More information