ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1
|
|
- Dulcie Norman
- 5 years ago
- Views:
Transcription
1 ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1
2 DATA SHEET SSF-86-3 ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1 Solid State Flasher: Description: The PDC model SSF-86 solid state flasher is a dual circuit flasher designed for the Traffic Control Industry. This unit is conservatively rated up to 20 A per circuit. The flash rate is flashes per minute and does not vary due to voltage or temperature variations. With the zero voltage switching design, there are no contacts to wear out or deteriorate due to arcing or corrosion. Also, extended life of the bulbs can be expected as well as reduced Radio Frequency Interference (RFI). The extruded aluminum heatsink provides more than adequate heat dissipation. Connector Pinout: Mates with a Beau P-5406-LAB or equivalent Electrical Characteristics: Zero voltage turn on Zero voltage turn off Tungsten Lamp or Gas Tubing Transformer load- Operating Voltage Mechanical V +-5 degrees 0A +-5 degrees Up to 20 A max VAC Length 8.40 inches Width.1.70 inches Height 4.18 inches Weight lbs Operating Temperature : Full load from 35 to +74 degrees C Guarantee: The flasher is fully guaranteed against all failures due to manufacturing defects for two years. P.O. Box 7172 #205, Stateline, NV PH (925) FAX (925)
3 ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-2
4 DATA SHEET SSF-86-3 ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-2 Solid State Flasher: Description: The PDC model SSF-86 solid state flasher is a dual circuit flasher designed for the Traffic Control Industry. This unit is conservatively rated up to 20 A per circuit. The flash rate is flashes per minute and does not vary due to voltage or temperature variations. With the zero voltage switching design, there are no contacts to wear out or deteriorate due to arcing or corrosion. Also, extended life of the bulbs can be expected as well as reduced Radio Frequency Interference (RFI). The extruded aluminum heatsink provides more than adequate heat dissipation. Connector Pinout: Mates with a Beau P-5406-LAB or equivalent Electrical Characteristics: Zero voltage turn on Zero voltage turn off Tungsten Lamp or Gas Tubing Transformer load- Operating Voltage Mechanical V +-5 degrees 0A +-5 degrees Up to 20 A max VAC Length 8.40 inches Width.1.70 inches Height 4.18 inches Weight lbs Operating Temperature : Full load from 35 to +74 degrees C Guarantee: The flasher is fully guaranteed against all failures due to manufacturing defects for two years. P.O. Box 7172 #205, Stateline, NV PH (925) FAX (925)
5 AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-2 The AP21 is a single-circuit, calendar-programmable, solid state time switch. It is primarily designed for switching electric circuits according to a pre-set time and date program. The AP21 auto prompting alpha-numeric display makes programming transfers fast and simple by using our AP21 software on a laptop. The AP21 may be powered from any120vac or 12VDC supply. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved.
6 AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance AP21 SPECIFICATIONS DESCRIPTION Fast and simple programming using our AP21 software on a laptop. DISPLAY KEYBOARD BACK-UP POWER ELECTRICAL CONNECTION OUTPUT POWER TIME BASE SIZE TEMPERATURE RANGE One-line, 16 character alpha-numeric Liquid Crystal Display (LCD) Sixteen-key, positive action push button 48-hour capacitive Terminal block (#12 to #20 AWG) optional CPC connector with harness SPDT relay rated at 15 amps 115 VAC resistive load 0.25 Watt at rest, 0.76 Watt relay ON, 12VDC AC Power = 60Hz line power DC Power = Temperature-compensated crystal with accuracy of +/-.005 seconds/day 7.6"H x 3.7"W x 1.55"D -30 to +74 Celsius AP21 FEATURES One-line, sixteen-character, Liquid Crystal Display (LCD) 16 character, alpha-numeric keypad Automatic Daylight Saving Time (DST) adjustments Time of day entered in 12-hour format Automatic Leap Year compensation 48-hour capacitive memory back-up no batteries to replace The display Auto Prompts the operator through the user-friendly programming process 16 powerful program steps Single Day, Weekend, Week Day, or Every Day programming capability for each program step 10 skip plans each skip plan prevents the time switch output from activating on a specific day or consecutive days SPDT relay output rated at 15 Amps at 115 VAC resistive load Works on 120VAC and 12VDC power sources AP21 ORDERING INFORMATION PART NUMBER DESCRIPTION Single-circuit time switch The AP21 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved
7 ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-3
8
9 ODOT ITB Section 4: Flashers, Timers, & Software Systems Item SERIES Model 254 (Edco ACP-340) 120 VAC Single Phase Surge Protective Device Technical Documentation The ASCO Model 254 filtering surge protector absorbs power line noise and switching transients that other suppressors and RFI filters may pass through. It designed to protect intersection controllers and other sensitive equipment from random time-base, memory loss and other more sever transient related problems. Model 254 can replace the existing EMI filter in the traffic cabinet if high frequency attenuation over 25 MHz is not required. Key Specs Voltage: 120 VAC Current: 10 Amp Connection: 1/4-20 Stainless Steel Lugs Mounting: Flange *See Ordering Information for model number selection General Technical Specifications Operating Voltage Clamping Voltage Operating Current Peak Surge Current Operating Frequency EMI Attenuation SPD Technology Modes of Protection Connection Type Operating Temperature Dimensions (in/mm) Weight (lb/kg) Warranty 120 VAC 395 VAC 10 A 32.5 ka/mode, 65 ka/total 47-63Hz 60 db typ Metal Oxide Varisters (MOV) w/ L-C Filter L-N, N-G 1/4-20 Stainless Steel Stud -40 C to +85 C H x W x L [60.3 x 79.4 x mm] 1lb, 13.5 oz. [ 0.84 kg] 5 years Features Industry-Leading Noise Filtering Nanosecond response time Incorporates series choke 5 Year Warranty V DANGER! Only qualified personnel should install or service this system. Electrical safety pre-cautions must be followed when installing or servicing this equipment. To prevent risk of electrical shock, turn off and lock out all power sources to the unit before making electrical connections or servicing. Seulement le personnel qualifié doit installer ou maintenir ce systéme. Des précautions de sécurité en électricité doivent être suivis lors de l installation ou de la maintenance de cet equipement. Pour eviter tout risque de choc électrique, débranchez et verouiller toutes les sources d alimentation de cet equipement avant de. Caution This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specifications. Appropriate precautions should be exercised. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only.
10 Installation Instructions Circuit Breaker 10A Max. Cabinet Power AC Hot Bus 120 VAC Input Earth Site Variable (opiton) Main Line Main Neutral Earth Model 254 Ground Line Out Neutral Out Protected Power Source (to controller and other sensitive electronics) Dimensions Ordering Information MODEL Former Model Name NF010AN5NO Edco ACP-340 APPLICATION 120VAC, 10A ASCO Power Technologies th St. North, Clearwater, FL surge.ascopower.com Copyright January Publication ID RevA
11 AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-3 The AP21 is a single-circuit, calendar-programmable, solid state time switch. It is primarily designed for switching electric circuits according to a pre-set time and date program. The AP21 auto prompting alpha-numeric display makes programming transfers fast and simple by using our AP21 software on a laptop. The AP21 may be powered from any120vac or 12VDC supply. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved.
12 AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance AP21 SPECIFICATIONS DESCRIPTION Fast and simple programming using our AP21 software on a laptop. DISPLAY KEYBOARD BACK-UP POWER ELECTRICAL CONNECTION OUTPUT POWER TIME BASE SIZE TEMPERATURE RANGE One-line, 16 character alpha-numeric Liquid Crystal Display (LCD) Sixteen-key, positive action push button 48-hour capacitive Terminal block (#12 to #20 AWG) optional CPC connector with harness SPDT relay rated at 15 amps 115 VAC resistive load 0.25 Watt at rest, 0.76 Watt relay ON, 12VDC AC Power = 60Hz line power DC Power = Temperature-compensated crystal with accuracy of +/-.005 seconds/day 7.6"H x 3.7"W x 1.55"D -30 to +74 Celsius AP21 FEATURES One-line, sixteen-character, Liquid Crystal Display (LCD) 16 character, alpha-numeric keypad Automatic Daylight Saving Time (DST) adjustments Time of day entered in 12-hour format Automatic Leap Year compensation 48-hour capacitive memory back-up no batteries to replace The display Auto Prompts the operator through the user-friendly programming process 16 powerful program steps Single Day, Weekend, Week Day, or Every Day programming capability for each program step 10 skip plans each skip plan prevents the time switch output from activating on a specific day or consecutive days SPDT relay output rated at 15 Amps at 115 VAC resistive load Works on 120VAC and 12VDC power sources AP21 ORDERING INFORMATION PART NUMBER DESCRIPTION Single-circuit time switch The AP21 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved
13 ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-4
14
15 ODOT ITB Section 4: Flashers, Timers, & Software Systems Item SERIES Model 254 (Edco ACP-340) 120 VAC Single Phase Surge Protective Device Technical Documentation The ASCO Model 254 filtering surge protector absorbs power line noise and switching transients that other suppressors and RFI filters may pass through. It designed to protect intersection controllers and other sensitive equipment from random time-base, memory loss and other more sever transient related problems. Model 254 can replace the existing EMI filter in the traffic cabinet if high frequency attenuation over 25 MHz is not required. Key Specs Voltage: 120 VAC Current: 10 Amp Connection: 1/4-20 Stainless Steel Lugs Mounting: Flange *See Ordering Information for model number selection General Technical Specifications Operating Voltage Clamping Voltage Operating Current Peak Surge Current Operating Frequency EMI Attenuation SPD Technology Modes of Protection Connection Type Operating Temperature Dimensions (in/mm) Weight (lb/kg) Warranty 120 VAC 395 VAC 10 A 32.5 ka/mode, 65 ka/total 47-63Hz 60 db typ Metal Oxide Varisters (MOV) w/ L-C Filter L-N, N-G 1/4-20 Stainless Steel Stud -40 C to +85 C H x W x L [60.3 x 79.4 x mm] 1lb, 13.5 oz. [ 0.84 kg] 5 years Features Industry-Leading Noise Filtering Nanosecond response time Incorporates series choke 5 Year Warranty V DANGER! Only qualified personnel should install or service this system. Electrical safety pre-cautions must be followed when installing or servicing this equipment. To prevent risk of electrical shock, turn off and lock out all power sources to the unit before making electrical connections or servicing. Seulement le personnel qualifié doit installer ou maintenir ce systéme. Des précautions de sécurité en électricité doivent être suivis lors de l installation ou de la maintenance de cet equipement. Pour eviter tout risque de choc électrique, débranchez et verouiller toutes les sources d alimentation de cet equipement avant de. Caution This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specifications. Appropriate precautions should be exercised. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only.
16 Installation Instructions Circuit Breaker 10A Max. Cabinet Power AC Hot Bus 120 VAC Input Earth Site Variable (opiton) Main Line Main Neutral Earth Model 254 Ground Line Out Neutral Out Protected Power Source (to controller and other sensitive electronics) Dimensions Ordering Information MODEL Former Model Name NF010AN5NO Edco ACP-340 APPLICATION 120VAC, 10A ASCO Power Technologies th St. North, Clearwater, FL surge.ascopower.com Copyright January Publication ID RevA
17 AP22 TIME SWITCH 2-Way Radio / Cellular / Ethernet / Wi-Fi ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-4 The AP22 Time Switch is a two-circuit, calendar programmable solid state time switch. It is used for switching electric circuits according to a pre-set time and date program. It has the ability to run up to ten different day plans and thirty-six different annual exception plans to accommodate different school calendars and/or traffic patterns throughout the year. The AP22 auto prompting alpha-numeric display makes programming fast and simple. Upload and download programming via 2-Way Radio, Cellular, Ethernet, Wi-Fi or Laptop. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved.
18 AP22 TIME SWITCH 2-Way Radio / Cellular / Ethernet / Wi-Fi AP22 SPECIFICATIONS DESCRIPTION Upload and download programming via 2-Way Radio, Cellular, Ethernet, Wi-Fi or Laptop. DISPLAY KEYBOARD BACK-UP POWER OUTPUT POWER TIME BASE Two-line, 16 characters per line Liquid Crystal Display (LCD) Sixteen-key, positive action push button Non-volatile memory Two SPDT relays rated at 15 amps 12VDC or 115 VAC resistive load Less than 0.25 Watt at rest, 0.6 watt with relay ON, 12VDC AC Power = 60Hz power line DC Power = Temperature-compensated crystal with accuracy of.35 seconds/day SIZE 10 3/8"h x 4 3/4"w x 2"d TEMPERATURE RANGE -30 to +74 Celsius AP22 FEATURES Two-line, sixteen-character, Liquid Crystal Display (LCD) Automatic Daylight Saving Time adjustments Program memory stored for years - no batteries to replace The user-friendly display auto-prompts the operator through the programming process Ten day plans, sixteen program steps per plan accommodate standard school day, school holidays, early dismissal days, summer school days, etc. Standard week plan programming uses any day plan for the most complicated school schedule Thirty-six annual programs use exception-day programming to assign any day plan to any calendar day(s) Two independent 15-amp relay outputs Program transfers from unit to unit Works on 120VAC and 12VDC power sources AP22 ORDERING INFORMATION PART NUMBER DESCRIPTION Two-output time switch with CPC connector and 48" wiring harness Program transfer cable AC power cable with connector The AP22 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved
19 AP22 TIME SWITCH 2-Way Radio / Cellular / Ethernet / Wi-Fi ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-5 The AP22 Time Switch is a two-circuit, calendar programmable solid state time switch. It is used for switching electric circuits according to a pre-set time and date program. It has the ability to run up to ten different day plans and thirty-six different annual exception plans to accommodate different school calendars and/or traffic patterns throughout the year. The AP22 auto prompting alpha-numeric display makes programming fast and simple. Upload and download programming via 2-Way Radio, Cellular, Ethernet, Wi-Fi or Laptop. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved.
20 AP22 TIME SWITCH 2-Way Radio / Cellular / Ethernet / Wi-Fi AP22 SPECIFICATIONS DESCRIPTION Upload and download programming via 2-Way Radio, Cellular, Ethernet, Wi-Fi or Laptop. DISPLAY KEYBOARD BACK-UP POWER OUTPUT POWER TIME BASE Two-line, 16 characters per line Liquid Crystal Display (LCD) Sixteen-key, positive action push button Non-volatile memory Two SPDT relays rated at 15 amps 12VDC or 115 VAC resistive load Less than 0.25 Watt at rest, 0.6 watt with relay ON, 12VDC AC Power = 60Hz power line DC Power = Temperature-compensated crystal with accuracy of.35 seconds/day SIZE 10 3/8"h x 4 3/4"w x 2"d TEMPERATURE RANGE -30 to +74 Celsius AP22 FEATURES Two-line, sixteen-character, Liquid Crystal Display (LCD) Automatic Daylight Saving Time adjustments Program memory stored for years - no batteries to replace The user-friendly display auto-prompts the operator through the programming process Ten day plans, sixteen program steps per plan accommodate standard school day, school holidays, early dismissal days, summer school days, etc. Standard week plan programming uses any day plan for the most complicated school schedule Thirty-six annual programs use exception-day programming to assign any day plan to any calendar day(s) Two independent 15-amp relay outputs Program transfers from unit to unit Works on 120VAC and 12VDC power sources AP22 ORDERING INFORMATION PART NUMBER DESCRIPTION Two-output time switch with CPC connector and 48" wiring harness Program transfer cable AC power cable with connector The AP22 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved
21 AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-7 The AP21 is a single-circuit, calendar-programmable, solid state time switch. It is primarily designed for switching electric circuits according to a pre-set time and date program. The AP21 auto prompting alpha-numeric display makes programming transfers fast and simple by using our AP21 software on a laptop. The AP21 may be powered from any120vac or 12VDC supply. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved.
22 AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance AP21 SPECIFICATIONS DESCRIPTION Fast and simple programming using our AP21 software on a laptop. DISPLAY KEYBOARD BACK-UP POWER ELECTRICAL CONNECTION OUTPUT POWER TIME BASE SIZE TEMPERATURE RANGE One-line, 16 character alpha-numeric Liquid Crystal Display (LCD) Sixteen-key, positive action push button 48-hour capacitive Terminal block (#12 to #20 AWG) optional CPC connector with harness SPDT relay rated at 15 amps 115 VAC resistive load 0.25 Watt at rest, 0.76 Watt relay ON, 12VDC AC Power = 60Hz line power DC Power = Temperature-compensated crystal with accuracy of +/-.005 seconds/day 7.6"H x 3.7"W x 1.55"D -30 to +74 Celsius AP21 FEATURES One-line, sixteen-character, Liquid Crystal Display (LCD) 16 character, alpha-numeric keypad Automatic Daylight Saving Time (DST) adjustments Time of day entered in 12-hour format Automatic Leap Year compensation 48-hour capacitive memory back-up no batteries to replace The display Auto Prompts the operator through the user-friendly programming process 16 powerful program steps Single Day, Weekend, Week Day, or Every Day programming capability for each program step 10 skip plans each skip plan prevents the time switch output from activating on a specific day or consecutive days SPDT relay output rated at 15 Amps at 115 VAC resistive load Works on 120VAC and 12VDC power sources AP21 ORDERING INFORMATION PART NUMBER DESCRIPTION Single-circuit time switch The AP21 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved
23 M2M CELLULAR COMMUNICATIONS MODEM Communicates With School Zone Flashers Using SMS Texting The RTC Model TSC2G is a compact communications modem that allows the user to connect an RTC Time Switch to a central computer using SMS texting. The TSC2G provides full, two-way communications from a central ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-9 computer to any Model AP22 or CPR2102 Time Switch via SMS texting eliminating the need for any additional infrastructure. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved.
24 M2M CELLULAR COMMUNICATIONS MODEM Communicates With School Zone Flashers Using SMS Texting M2M FEATURES Two-way communication with AP22 and CPR2102 time switches using SMS texting (no additional infrastructure required) Omni antenna typically mounts inside the flasher cabinet, an external Omni antenna is available if required LED indicator for power and SMS network connection Compact size: 3.4"w x 2.4"h x 1"d with mounting tabs Simple, plug-and-play operation Make program changes anytime day or night Operating temperature range: -30 to +75 Celsius M2M SPECIFICATIONS DESCRIPTION DIMENSIONS 3.4"w x 2.4"h x 1"d POWER OPERATING TEMPERATURE SMS ANTENNA OPTIONS PROGRAMMING MANUAL CONTROL VALIDATE PROGRAMMING 12VDC, powered from DB9 on time switch -30 to +75 Celsius Short Message Service Omni antenna mounted inside the flasher cabinet (standard) Omni antenna mounted outside the flasher cabinet (if required) Make programming changes to your school zone flashers anytime from a PC or laptop connected to the internet Send manual control commands at anytime, day or night Validate the program in any time switch at anytime, day or night GPS Time sync reference and map location services M2M SERVICE PLANS: Choose from a 5-year or 10-year service agreement RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved
25 M2M CELLULAR COMMUNICATIONS MODEM Communicates With School Zone Flashers Using Cellular Technology The RTC M2M is a compact communications modem that allows the user to connect an RTC Time ODOT ITB Section 4: Flashers, Timers, & Software Systems Item G Modem With Paddle Antenna, Less Communication Plan Switch to a central computer using RTC Connect software. The M2M provides full, two-way communications from a central computer to any Model AP22 or CPR2102 Time Switch. This eliminates the cost and maintenance of additional infrastructure. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved.
26 M2M CELLULAR COMMUNICATIONS MODEM Communicates With School Zone Flashers Using Cellular Technology M2M FEATURES Simple, plug-and-play operation Powered directly by RTC time switches with no external power supply needed Make program changes anytime Modems are fully certified and carrier approved Two-year warranty Time Switch time is synchronized daily with cell tower time Can be mounted directly to time switch Antenna typically mounts inside the flasher cabinet; an external antenna is available if required; other antenna optional, as needed LED indicator for power and cellular network connection Extended warrranties up to five years available M2M CERTIFICATIONS REGULATORY COMPLIANCE FCC Class B (US), IC (Canada) SAFETY UL (US), cul (Canada) QUALITY MIL-STD-810: high-temp, low-temp, cold dwell, random vibration and sine vibration SAE J1455: random vibration and sine vibration M2M SERVICE PLANS Choose from one, five, or ten-year service agreement OPTIONAL GPS ENABLED DEVICE AVAILABLE Time sync reference and map location services M2M SPECIFICATIONS DESCRIPTION DIMENSIONS 2.45"W x 3.17"H x 1.16"D WEIGHT.65 LB TIME SYNC Cell System GPS CHASSIS TYPE Aluminum OPERATING TEMPERATURE -40 to +85 Celsius HUMIDITY Relative Humidity 15% to 93% non-condensing SMS Short Message Service Supported PERFORMANCE HSPA+ FREQUENCY BAND Hepta-band 850/900/AWS 1700/ MHz RTC CONNECT TM COMMUNICATION FLOW RTC DATA SERVER CELL CARRIER Central Traffic Office Running RTC Connect TM Two-way Internet Communication Two-way Internet Communication Two-way Cell Communication RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE FAX RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas RTC Manufacturing, Inc. All Rights Reserved
ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1
ODOT ITB 063-17 Item 4-1 DATA SHEET SSF-86-3 ODOT ITB 063-17 Item 4-1 Solid State Flasher: Description: The PDC model SSF-86 solid state flasher is a dual circuit flasher designed for the Traffic Control
More information400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual
400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual IO-70104 Rev 1, 1/2014 EMERSON NETWORK POWER SURGE PROTECTIVE DEVICE
More information300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual
Power Switching & Controls For Business-Critical Continuity 300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual EMERSON
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationToll Free: Tel: Fax:
Toll Free: 1-888-865-6888 Tel: 510-226-8368 Fax: 510-226-8968 Email: sales@rackmountmart.com User Manual LCDK 1070 DVI-D KVM Legal Information First English printing, October 2002 Information in this document
More informationRugged MediaConverter
Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006
More informationSurge Protective Devices. Installation & Operation Manual. Model 570/575. Model 575 Model 570 Model 565 Model 560. Model 560/565
Surge Protective Devices Installation & Operation Manual Model 570/575 Model 560/565 Model 575 Model 570 Model 565 Model 560 Installation, Operation and Maintenance Manual 2 ASCO SURGE PROTECTIVE DEVICE
More informationOmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial
OmniSmart 120V 330VA 225W UL 60601-1 Medical Grade Line-Interactive UPS, Tower, DB9 Serial MODEL NUMBER: OMNISMART350HG Highlights 330VA line interactive tower UPS Maintains sine-wave 120V nominal output
More informationAP41 / AP81 SERIES TIME SWITCHES
FN:AP41_81M1.DOC AP41 / AP81 SERIES TIME SWITCHES AP41 AP81 TABLE OF CONTENTS INTRODUCTION 2 SPECIFICATIONS 2 INSTALLATION 5 FRONT PANEL DESCRIPTION 7 OPERATION 8 Filling out the Program Record Sheet 8
More informationSurge Protectors and Digital Timer
NEW! New Energy Saving Power Center and Digital Timer Surge Protectors and Digital Timer NEW! EMF -3 Three Outlet Surge Protector with 2 USB Chargers 15 Amp/125V/1875W Converts one grounded outlet of similar
More informationProtect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing
Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Housing MODEL NUMBER: STRIKER Highlights 7 NEMA 5-15R outlets one designed for a bulky transformer 1080-joule surge protection
More informationMAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS
MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...
More informationProtect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing
Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Housing MODEL NUMBER: TLP1008TEL Highlights 10 NEMA 5-15R outlets, including 4 for bulky transformers
More informationUser Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.
User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply
More informationPHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL
PHASETRONICS Specialists EP1 Series Power Control Single Phase SCR 10-50 Amps OPERATION & SERVICE MANUAL Phasetronics, Inc. P.O. Box 5988 1600 Sunshine Drive Clearwater, FL 33765 (727)573-1900 FAX(727)573-1803
More informationICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017
ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules
More informationIndustrial Power Supplies
75-600 Watt Features Switch mode power supplies for DIN-rail mounting 4 power ranges with 3, 6, 12 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise EMI complies
More informationRuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options
Features and Benefits The RuggedMC is an industrially hardened fiber optical media converter specifically designed to operate in harsh environments such as those found in electric utility substations and
More informationLevel-Lance Model 5400A
Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing
More informationIES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v
IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire
More informationPower Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. The Hardened Ethernet Extender introduced here provides one channel for Ethernet over existing
More information1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console
1993 Specifications CSJ 0598-01-057 1.0 Description SPECIAL SPECIFICATION ITEM 6398 Transportation Management Console This Item shall govern for the furnishing and installation of Transportation Management
More informationBSPD Surge Protective Devices
BUSSMANN Supersedes December 2016 SERIES BSPD Surge Protective Devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on Contents Description Page Introduction 2 Applications 2 Features
More informationSpecifications, Installation, and Operating Instructions
Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.
More informationModel 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)
Surge Protective Devices Installation & Operation Manual Model 160 (16-Channel Coaxial) Model 186 (16 or 48 Channel Hi Speed Data Line Protector) Model 247 (120VAC Active Tracking Filter) Model 160 (EDCO
More informationStride Industrial Ethernet Switches
8-Port Ethernet Switch with Fiber Port STRIDE Industrial Ethernet Switch with eight 10/100BaseT RJ45 Ethernet ports and one 100BaseFX Fiber optic port (ST type multimode fiber connector for links up to
More informationLiebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System
Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationHardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical
More informationProtect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing
Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Housing MODEL NUMBER: TLP1008TEL Highlights 10 NEMA 5-15R outlets, including 4 for bulky transformers
More informationSmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out
SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)
More informationProtect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11
Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER7TEL Highlights 7 outlets / 7-ft. cord 2520 joule rating Modem/fax surge protection $75,000
More informationSmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System
SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System MODEL NUMBER: SVX120KL Highlights 120kVA / 120kW modular, scalable, 3-phase, Large-Frame tower
More informationOmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer
OmniSmart 230V 350VA 225W CE/IEC 60601-1 Medical Grade Line-Interactive UPS with Built-In Isolation Transformer MODEL NUMBER: OMNIX350HG Highlights 350VA line interactive tower UPS Professional features
More informationPower Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical
More informationInternet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB
Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery
More informationSurge Protection Solutions. Industrial Market Automation Market OEM Market
Surge Protection Solutions Industrial Market Automation Market OEM Market ASCO Power Technologies is Combining the Surge Protection solutions of Advanced Protection Technologies, EDCO, Islatrol & Emerson
More informationProtect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11
Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER6TEL Highlights 7 outlets / 6-ft. cord 1080 joule rating Modem/fax surge protection $50,000
More informationRuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter
Features and Benefits 4-Ethernet Ports with Optional Dual Fiber Optics Three configurations to choose from: z2 10/100TX ports + 1 100FX port (SC/ST) z2 10/100TX ports + 2 100FX port (MTRJ/LC) z4 10/100TX
More informationModel #: INTERNET750U
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: INTERNET750U Internet Office UPS System - All-in-one SOHO solution Highlights
More informationGrid to Chip Surge Protection Product Catalog
Grid to Chip Surge Protection Product Catalog Surge Protection For Business-Critical Continuity TM Power Quality Solutions for ALL Your Application Needs Dirty power is a problem. Whether it s called a
More informationInternet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB
Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB MODEL NUMBER: INTERNET550U Highlights 550VA ultra-compact 120V standby UPS Maintains AC output during power failures 4 UPS battery
More informationSignamax Connectivity Systems
Signamax Connectivity Systems Hardened Ethernet Switch Model -065-7405TB 065-7408ATB 065-74091FXSTTB 065-74091FXSCTB U S E R S G U I D E 1 Quick Start Guide Hardened Ethernet Switch This quick start guide
More informationIndustrial Power Supplies
50-600 Watt Features Switch mode power supplies for DIN-rail mounting 6 power ranges with 2, 3, 6, 12, 20 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationAI130 AIswitch Series 130 Chassis Installation Guide
AI130 AIswitch Series 130 Chassis Installation Guide Part Number QR-130 Rev 3 2007 by Kentrox, Inc. All rights reserved. Copyright 2007 by Kentrox, Inc. All Rights Reserved. The material discussed in this
More informationSPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System
2004 Specifications CSJ 0902-48-433 SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System 1. Description. Furnish and install Digital Video Encoder/Decoder (Ethernet) System (DVE/DES)
More informationInstallation Job Aid for Ethernet Routing Switch 3600 Series
Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions
More informationSCADAPack E 5405 Digital Input Hardware Manual
SCADAPack E 5405 Digital Input Hardware Manual 2 SCADAPack E 5405 Digital Input Hardware Manual Table of Contents Part I 5405 Digital Input Module 3 1 Technical... Support 3 2 Safety... Information 4 3
More informationSTATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The
More informationHardened PoE Ethernet Switch
Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description
More informationPDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL
PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage
More information550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure
550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure MODEL NUMBER: AV550SC Highlights 4 AC outlets (including 1 delayon outlet for router) Automatic recycle/reset
More informationLine Impedance Stabilization Network (LISN)
Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any
More informationEco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection
Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection MODEL NUMBER: AV88SATG Highlights 8 outlets / 8-ft. cord 2880 joule rating Auto/Manual switch offers GREEN
More informationRT4F-110V/25A RECTIFIER
The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V
More information4600 Series RAID-Enabled
4600 Series RAID-Enabled Industrial PCs 12 and 15-inch Color LCD Touch Monitor 4612/ 4615/ 1546 AC100/240V SVGA XGA Models: 4612T-1300 RAID/ 4615T-1300 RAID/ 1546-1300 RAID 12-inch 15-inch Windows 2000
More informationPowerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)
Powerstar PS3204rm2u PS3204 tower (120V) 3.4 H x16.9 W x19.7 D 85 x 430 x 497mm Model upgrade from PS3200 (GXT2) and PS3203 (GXT3)- now using Liebert GXT4 electronics Double Conversion true online type
More informationHardened Media Converter
Quick Start Guide This quick start guide describes how to install and use the hardened media converter. This is the media converter of choice for harsh environments constrained by space. Physical Description
More informationModel #: ECO350UPS. 350VA Eco Energy-Saving UPS System. Highlights. Description. Features
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: ECO350UPS 350VA Eco Energy-Saving UPS System Highlights 350VA power saving, ultra-compact
More informationTAA-Compliant ECO Series 120V 550VA 300W Energy-Saving Standby UPS with USB monitoring and 8 Outlets
TAA-Compliant ECO Series 120V 550VA 300W Energy-Saving Standby UPS with USB monitoring and 8 Outlets MODEL NUMBER: ECO550UPSTAA Highlights Federal Trade Agreements Act / TAA Compliant for GSA Schedule
More informationIsobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing
Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR4ULTRA Highlights 4 NEMA 5-15R outlets in exclusive isolated filter banks
More informationSPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System
2004 Specifications CSJ 2374-01-153, etc. SPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System 1. Description. Furnish and install the microwave vehicle detection (MVD) system as shown in the
More informationPower Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF
3 Power Supplies GL Series: Single & Multi Output Switchers The new GL series provides a broad range of AC/DC power supply solutions that covers power ratings from 25 watts to 500 watts for use in various
More informationSingle Phase Systems-North American PC125/PC420 Series
Single Phase Systems-North American PC125/PC420 Series Enclosure Power Distribution Units (epdu ) PC125-C Front RACK MOUNTED 19 x 3.4 (2U) x 8.5. Approximate shipping weight: 19 lbs. (12) NEMA OUTLETS
More informationECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB, LCD Display and 12 Outlets
ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB, LCD Display and 12 Outlets MODEL NUMBER: ECO850LCD Highlights 850VA ultra-compact 120V standby UPS, LCD status and control display Maintains
More informationIsobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal
Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal MODEL NUMBER: ISOTEL4ULTRA Highlights 4 NEMA 5-15R outlets in exclusive isolated filter
More informationSurge Protective Devices. STV25K Series. Instruction Manual
Surge Protective Devices STV25K Series Instruction Manual Contents 1.0 Installation & Operation... 4 1.1 Environment... 4 1.2 Mechanical Dimensions... 4 1.3 DIN Rail Mounting... 5 1.4 Supplemental Enclosures...
More informationPOS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection
POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection MODEL NUMBER: POS500 Highlights 500VA low-profile tower 120V standby UPS Maintains AC output during power
More informationUser s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis
User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis The Transition Networks CPSMC0200-2x0 series dual-slot PointSystem chassis is designed for installation of one or two selectable Transition Networks
More informationEaton s SPD Series for integration into electrical distribution equipment
Technical Data TD01006E Supersedes August 2009 Eaton s SPD Series for integration into electrical distribution equipment Contents Description Page Introduction....2 Applications....2 Features....2 Standards
More information5401 and 5402 Digital I/O Modules
50 and 50 Digital I/O Modules Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical
More informationTAA-Compliant POS Series 120V 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection
TAA-Compliant POS Series 120V 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection MODEL NUMBER: POS500TAA Highlights Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
More informationTPE 1464 Series Pressure Transducer
TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm
More informationECO Series 120V 900VA 480W Energy-Saving Standby UPS with USB, Muted Alarm and 12 Outlets
ECO Series 120V 900VA 480W Energy-Saving Standby UPS with USB, Muted Alarm and 12 Outlets MODEL NUMBER: ECO900UPSM Highlights 900VA ultra-compact 120V standby UPS, energy-saving ECO outlets Audible alarm
More informationSLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters
Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:
More informationECO Series 120V 350VA 180W Energy-Saving Standby UPS with USB and 6 Outlets
ECO Series 120V 350VA 180W Energy-Saving Standby UPS with USB and 6 Outlets MODEL NUMBER: ECO350UPS Highlights 350VA ultra-compact 120V standby UPS, energy-saving ECO outlets Maintains AC output during
More informationIES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v
IES-0823 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail User Manual v1.00-1206 Preface A member of the growing family of rugged switches, this switch addresses a need for a smaller switch. This switch
More informationSmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules
SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules MODEL NUMBER: SVX90KM3P5B Highlights 90kVA/90kW Modular, Scalable,
More informationMRC 7000 Proven Recording Reliability that Became the Industry Standard!
Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables
More informationIsobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing
Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR8ULTRA Highlights 8 NEMA 5-15R outlets in exclusive isolated filter banks
More informationSmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output
SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More informationIsobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing
Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing MODEL NUMBER: ULTRAFAX Highlights 2 NEMA 5-15R surge-protected outlets 1410-joule surge
More information7-Outlet Home/Business Theater Surge Protector, 6-ft. Cord, 2100 Joules, Tel/Modem/Coax Protection
7-Outlet Home/Business Theater Surge Protector, 6-ft. Cord, 2100 Joules, Tel/Modem/Coax Protection MODEL NUMBER: HT706TSAT Highlights 7 outlets / 6 ft. cord 2100 joule rating 2-line 2.2 GHz gold coaxial
More informationUPS READY POWER DISTRIBUTION ASSEMBLY
UPS READY POWER DISTRIBUTION ASSEMBLY FOR TRAFFIC CABINETS with LED Signals INSTALLATION & OPERATOR S MANUAL VERSION 1.2 1 Note The instructions contained in this manual are not intended to cover all of
More informationIsobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing
Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR6 Highlights 6 NEMA 5-15R outlets in exclusive isolated filter banks Network-grade
More informationIsobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing
Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing MODEL NUMBER: IBAR12 Highlights 12 NEMA 5-15R outlets in exclusive isolated filter
More informationAVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port
AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR550U Highlights 550VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to
More informationH-series (Rectifier Module)
H-series (Rectifier Module) Overview: The rectifier modules provide unprecedented power density and power levels in a true plug and play format. With a wide range of available voltages, power ratings,
More informationIsobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal
Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal MODEL NUMBER: ISOBAR6DBS Highlights 6 NEMA 5-15R outlets in exclusive isolated filter
More information3500/32M 4-Channel Relay Module
3500/32M 4-Channel Relay Module Bently Nevada* Asset Condition Monitoring Description The 4-Channel Relay Module is a full-height module that provides four relay outputs. Any number of 4-Channel Relay
More informationdedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October 2002 Information in
More informationGLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF
Power Supplies GL Series: Single & Multi Output Switchers The new GL series provides a broad range of AC/DC power supply solutions that covers power ratings from 25 watts to 500 watts for use in various
More informationAVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port
AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR700U Highlights 700VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to
More informationNOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."
Back to Contents Page System Overview Dell PowerEdge 1600SC Systems Service Manual System Features Supported Systems Power Protection Devices Other Documents You May Need Specifications System Features
More informationEasy To Use OEMS Take Note
MA7200 Features Sensorless Vector Precise speed and torque control for the most demanding system performance. Simple set-up through autotuning function. The MA7200 can be operated in sensorless vector
More informationAVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port
AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR750U Highlights 750VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to
More information