1 EVC Series Quick Start Guide English Issue 3.book Page 1 Friday, March 11, :38 PM Quick Start Guide Variable Speed Drive Part Number: Issue: 3

2 Original Instructions For the purposes of compliance with the EU Machinery Directive 2006/42/EC. General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional operating parameters of the equipment or from mismatching the variable speed drive with the motor. The contents of this guide are believed to be correct at the time of printing. In the interests of a commitment to a policy of continuous development and improvement, the manufacturer reserves the right to change the specification of the product or its performance, or the contents of the guide, without notice. All rights reserved. No parts of this guide may be reproduced or transmitted in any form or by any means, electrical or mechanical including photocopying, recording or by an information storage or retrieval system, without permission in writing from the publisher. Drive firmware version This product is supplied with the latest hardware specific firmware version. If this drive is to be connected to an existing system or machine, all drive firmware versions should be verified to confirm the same functionality as drives of the same model already present. This may also apply to drives returned from a Service Centre or Repair Centre. If there is any doubt please contact the supplier of the product. The firmware version of the drive can be verified by viewing Pr ; it is also listed at the bottom of this page. Drive Software version This product is supplied with the latest application specific software version. The software version can be verified by viewing Pr ; it is also at the bottom of this page. WARNING This document is a guide only. It does not provide safety information. Incorrect installation or operation of the drive could result in injury or equipment damage. Refer to the Drive User Guide for essential safety information. Copyright March 2016 Drive Firmware version: XX.XX onwards Drive Software version: onwards

3 Contents 1 Drive wiring Fusing Line reactor / Choke (optional depending on local regulations) EMC filter Drive-compressor cables AC mains cables System control Analog / Digital Modbus Keypad Analog I/O configuration Modbus configurations Keypad shortcuts Parameters Configuration control word parameter System control word parameter Menu 0 - compressor specific parameters PC Tools - HVAC Connect Quick start commissioning / start-up using HVAC Drive Connect (V onwards) Quick Start Guide

4 1 Drive wiring A Warning contains information which is essential for avoiding a safety hazard. WARNING For detailed information on making the necessary power connections to the drive, to fusing and to EMC accessories, please refer to the documentation listed below. Be sure to follow local regulations when deciding whether or not EMC filters and line reactors will be required for your specific application. 1.1 Fusing Refer to section 4.3 of the Drive User Guide for acceptable fuse amperage and class Line reactor / Choke (optional depending on local regulations) Refer to section in the Drive User Guide for line reactor considerations. 1.3 EMC filter Refer to section in the EMC Data sheet for external EMC filter selection Drive-compressor cables Refer to section 4.3 of the Drive User Guide for details on drive output cable size. 1.5 AC mains cables The final mains connections should be made last, after verifying all other wiring. Refer to section 4.3 of the Drive User Guide for details on drive input cable size. 4 Quick Start Guide

5 Figure 1-1 below illustrates the required power connections for the AC mains, the optional EMC accessories, grounding, and the compressor. The motor terminals for the compressor are always located on the bottom of the drive. However, the location of the AC mains terminals may vary by drive model. Figure 1-1 AC and Compressor connections AC Connections Motor Connections L1 L2 L3 PE U V W Fuses L1 Optional EMC filter Optional line reactor L2 Mains Supply L Supply Ground 6 7 Drive Compressor U L1 V L2 W L3 ground ground Drive wiring System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 5

6 2 System control The drive can be controlled in one of two ways: in analog / digital control mode, or in Modbus control mode. The drive is configured to run in analog / digital control mode by default. If the application requires Modbus control then some drive parameters will need to be adjusted as outlined in section 2.2 Modbus on page Analog / Digital The drive is set up to run in analog / digital control mode by default. The following connections are the preferred connections to run the drive (as illustrated in Figure 2-1): Drive Enable (between pins 22 and 31) Run/Stop (between pins 22 and 26) Drive Reset (between pins 22 and 25) Compressor On (indicated from pin 24) Speed Reference 0 to 10 V (between pins 4, 8 and 11) Pressure Sensors 2 x 4-20 ma (between pins 5 and 22, 7 and 22) Stator Heating (between pins 22 and 27) Defrost Control (between pins 22 and 28) User Trip e.g. OEM emergency stop (between pins 22 and 29) Drive OK on Relay (between pins 41 and 42) The following connections are used at a minimum to put the drive in to a basic test mode: Drive Enable (between pins 22 and 31) Run/Stop (between pins 22 and 26) Drive Reset (between pins 22 and 25) Speed Reference 0 to 10 V (between pins 4, 8 and 11) Set Pr bit 3 = 1 to disable Envelope Control Refer to section 6 in the Drive User Guide for specific details regarding these features and their corresponding connections. If the drive has previously been configured to run in Modbus control mode then there are two ways to configure the drive back into analog / digital control mode. 1. The simplest option is to reset the drive back to factory defaults. The drawback to this method is that ALL parameters are defaulted. If other drive parameters have been customized then they will be lost. Position the keypad to any "zero" parameter (i.e. Pr MM.000); press enter. Scroll up to "Reset 60 Hz defs", press enter. 2. The second option is to manually configure the drive back into the analog / digital control mode. This method will retain all other parameter modifications previously made to the drive. Set the following parameters: Pr bit 8 = 0 Adjust other features in Pr as required Verify that Pr = 0 Reconfigure analog inputs according to Table 2-1 Control drive operation via I/O switch on pins 26 and 31 Details on Pr and Pr can be found in section 4.1 and section Quick Start Guide

7 The following figure illustrates the preferred connections to control the drive and compressor. Figure 2-1 Connections available in analog / digital control mode Polarized connectors * The Drive Enable /Pressure Switch terminal is a positive logic input only. NOTE Suction Pressure Sensor 4-20 ma, 18 Bar Discharge Pressure Sensor 4-20 ma, 50 Bar Speed signal 0-10 V +10 V GND Compressor On Drive Reset Start / controlled stop Stator Heating On Defrost Control User Trip Drive Enable Pressure Switch* Drive OK Signal Signal Signal Optional Optional 0 V common External 24 V supply (not used) When the drive is configured for analog / digital control mode (i.e. Pr bit 8=0), a logic high signal on the Start / Controlled Stop pin 26 will turn on the compressor; a logic low signal on pin 26 will initiate the controlled shutdown sequence V 8 AI V common 21 0 V common V 23 0 V common V common V common +AI1 -AI1 AI2 AO1 AO2 Digital I/O 1 Digital I/O 2 Digital I/O 3 Digital I/O 4 Digital I5 Digital I6 Relay (Over voltage category II) System control System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 7

8 The following figure illustrates the system connections for analog / digital control mode. Note that all system features and control take place via pairs of signal wires as shown in Figure 2-1. Figure 2-2 Analog / digital control mode OEM controller DLT Start/Stop and Stator Heating Control 2 x digital input Speed Reference command (rpm) 0-10 VAnalog signal User Trip, Drive Reset,Defrost control 3 x digital input Drive OK Relay Compressor On 1 x Digital Output AI2 Pevaporating Discharge Temperature AI1 Pcondensing Pe For Super Heat Control Condenser Pressure (Pc) Condenser Motor Power Expansion Valve Fan Compressor * Evaporator Evaporator Pressure (Pe) * Compressor functionality provided by the dedicated drive software. 8 Quick Start Guide

9 Table 2-1 lists the parameters and corresponding values that need to be configured before the drive will operate in analog / digital control mode using envelope control. The following parameters are the default values for the drive assuming that an 18 bar sensor is used for suction and a 50 bar sensor is used for discharge. Table 2-1 Settings for Analog Speed Command with Envelope Control Parameter Description Value Device AI1 Control 4 (4-20 ma) Analog Input 1 Suction Pressure (4-20 ma) Or Analog Reference Modbus setting 4 (4-20 ma) 6 (0-10 V) Scaling Destination Address AI2 Control (4-20 ma) Analog Input 2 Discharge Pressure (4-20 ma) Or Analog Reference 4 (4-20 ma) 6 (0-10 V) Scaling Destination Address AI3 Control 9 6 (Therm No (Volt) Analog input 3 Trip) 0-10 V Speed Reference Scaling 1 (Volt) Destination Address The drive assumes that the pressure transducer is rated in [bar]. However, the drive is configured to display the measured suction and discharge pressure in [PSIG]. The drive can be configured to display the pressures in [bar] by adjusting Pr [bit 5]=1. The scaling values for Pr and Pr in Table 2-1 will need to be recalculated under the following scenarios: 1. The suction transducer is not rated for 18 [bar] and/or the discharge transducer is not rated for 50 [bar]. 2. The user wants to view the pressure in [bar] units. System control System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 9

10 Example 1: Calculating the scaling values for an 18 bar (suction) transducer and for a 50 bar (discharge) transducer; displaying units in [bar]. Set Pr bit 5 = 1. 18[bar] 100 Pr = = [bar] 100 Pr = = Example 2: (drive default values) Calculating the scaling values for an 18 bar (suction) transducer and for a 50 bar (discharge) transducer; displaying units in [PSIG]. Set Pr bit 5 = 0. Note that a factor of 14.5 [PSIG] per 1 [bar] is added in to the equation below. Pr = 18[bar] [ PSIG per bar] = Pr = 50[bar] [ PSIG per bar] = In summary, use the following equations to calculate the scaling values for Table 2-1. ( FullBarValue) 100 scale[psig] = = scale[bar] = ( FullBarValue) Quick Start Guide

11 2.2 Modbus This section will guide you through the steps to configure the drive to run in Modbus control mode. The following connections are required to run the drive (as illustrated in Figure 2-3): Drive Enable/Pressure Switch (between pins 22 and 31) Connection to OEM controller via RJ485 port Figure 2-3 Connections available in Modbus control mode V 1 8 Pin 2 - TxRx Pin 3-0V/GND Pin7 - /TxRx Drive Enable Pressure Switch Once the appropriate control connections have been made to the drive then adjust the following parameters to configure the drive into Modbus control mode: Set the following parameters: Pr bit 8 = 1 (default is 0) Adjust other features in Pr as required Adjust Pr = 0.0 Adjust Pr = 0.0 Adjust Pr = 0.0 Set desired speed with Pr Control drive operation from PLC via adjusting the bits in Pr as required Details on Pr and Pr can be found in section 4.1 and section 4.2. System control System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 11

12 Figure 2-4 illustrates the system connections for Modbus control mode. Note that all system features and control take place via a network patch cable and not through individual pairs of wire as would be used in the analog / digital control mode. Figure 2-4 Modbus control mode OEM controller Reset Start / Stop and Stator heating control Stator heat Defrost control OEM trip Speed reference command (rpm) Drive condition (alerts / trips / lockouts) Pc and Pe Discharge Line Temperature Discharge Temperature Pe Pc Condenser Pressure (Pc) Expansion Valve Condenser Fan Compressor* Motor Power Evaporator Evaporator Pressure (Pe) * Compressor functionality provided by the dedicated drive software. 12 Quick Start Guide

13 3 Keypad A keypad is used view and make adjustments to the drive parameters. There are two optional keypads that can be used with the drive: a snap on keypad that physically attaches to the drive or a remote keypad that can be mounted to the outside of an enclosure. The snap on keypad connects to the drive in the same way independently of the control mode being used; the remote keypad connection will vary as described below depending on the control mode. 3.1 Analog I/O configuration The following drive parameters will need to be configured via HVAC Connect or a temporary snap on keypad before the remote keypad will begin to function (as illustrated in Figure 3-1): Adjust Serial Baud Rate Pr = Adjust Serial Address Pr = 1 Adjust Serial Mode Pr = 8 2 NP Set Pr = 'On' (this parameter will then turn back to 'Off' automatically) Save the drive parameters Adjusting the drive parameters can be accomplished in one of three ways: 1. Temporarily use a clip on keypad to make the changes. 2. Download and install the HVAC Connect software to communicate with the drive via an optional USB-to-RJ485 adaptor. 3. Use a pre-configured smart card and adaptor to "clone" the drive parameters. The remote keypad can be connected to either of the RJ485 ports on the drive via a RJ45 cable. Alternatively, if none of the three the items above are available to make changes to the drive parameters, a KI-485 Adaptor can be purchased. This alternative method will allow the remote keypad to function without having to change ANY drive parameters. Refer to section 3.2 for additional details. Figure 3-1 Remote keypad via 485 port NOTE 4 RJ45 cable Snap on Keypad (optional) Remote Keypad (optional) The snap on keypad and the remote keypad can both be used simultaneously in this configuration. Or Keypad System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 13

14 3.2 Modbus configurations When the drive is configured for Modbus control mode, an OEM controller is communicating as the master to the drive. Subsequently, the optional remote keypad is also a 485 master device. And while the drive has two RJ485 ports, they make up a single 485 channel. Therefore the second 485 port cannot be used for any other reason except to "daisy chain" the OEM controller to additional drives if the application requires. Therefore, the only way to connect an optional remote keypad to the drive would be through the use of a KI-485 Adaptor (as illustrated in Figure 3-2). Figure 3-2 Remote keypad via KI-485 Adaptor Snap on Keypad (optional) OEM controller Or 4 KI-485 Adaptor RJ45 cable Remote Keypad (optional) One benefit of using the KI-485 Adaptor, in either analog / digital control mode or in Modbus control mode, is that no parameter changes are required before the remote keypad will function with the drive. 14 Quick Start Guide

15 3.3 Keypad shortcuts This section explains some of the time saving features that are built into the keypads The keypad's "user settings" menu While scrolling through the parameters, press the return button twice and hold on the last press for 1 second. This will allow the user to view the keypad settings such as: Language options Backlight level Keypad software version Date/time features (for keypads with RTC) To exit the keypad settings menu, press the return button The "1001" save Drive parameters are usually saved by entering into any Pr MM.000 and scrolling up to select "Save parameters". However, this save will only work when the drive is not in a tripped state. Commissioning a drive via 24V or bench testing a drive via 24V, for example, would both put the drive in an "Under Voltage" tripped state which will not allow for any modified parameters to be saved within the drive using the traditional save method. To save parameters while the drive is in any tripped state, use the following procedure. Position the keypad to any "zero" parameter (i.e. Pr MM.000); press enter. Press the left arrow three times and then press the up arrow once to enter a value of '1000'. Press the right arrow three times and then press the up arrow once to enter a value of '1001'. Press the red 'stop' button to save the drive parameters The "multi-press" functions Simultaneously pressing the left and right arrows while scrolling through the parameter menus will bring the keypad directly to menu 0 (i.e. Pr 00.PPP). Simultaneously pressing the up and down arrows while scrolling through the parameter menus will bring the keypad directly to parameter 0 within that menu (i.e. Pr MM.000). Example: Pressing the left and right arrows simultaneously and then subsequently pressing the up and down arrows simultaneously is the fastest way to return back to Pr Simultaneously pressing the up and down arrows while editing a parameter value will reset the value to zero The "go to parameter" If the security parameter Pr is set to 'all menus', then the quickest way to move to a parameter that would otherwise require many key presses to navigate to is: Hold in the enter key for 1 second Enter in a parameter of interest; press enter. Keypad System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 15

16 4 Parameters 4.1 Configuration control word parameter Pr , containing the configuration control word, is used to control the drive in both analog / digital control mode and in Modbus control mode. To allow for simple drive configurations in Modbus control mode, all drive and compressor functions are enabled/disabled using this single bitwise parameter: Pr Table 4-1 Pr {Pr } Bit Key to the Configuration Parameter (the first bit, aka. the least significant bit, is on the right side of the binary number): Name Function Default 0 (1 st ) Variable switching frequency 0: Disable, 1: Enable 0 (Disable) 1 (2 nd ) Single phase AC input detection 0: Disable, 1: Enable 0 (Disable) 2 (3 rd ) Short cycle protection 0: Enable, 1: Disable 0 (Enable) 3 (4 th ) Envelope control 0: Enable, 1: Disable 0 (Enable) 4 (5 th ) DLT Temperature unit 0: Fahrenheit, 1: Celsius 0 ( F) 5 (6 th ) Envelope Pressure unit 0: Psig, 1: Bar 0 (Psig) 6 (7 th ) Oil control 0: Enable, 1: Disable 0 (Enable) 7 (8 th ) Defrost cycle control 0: Disable, 1: Enable 0 (Disable) 8 (9 th ) Control source for Start/run and stator heater 0: From Terminal digital input 1: From Modbus or Keypad 0 (Digital) 9 (10 th ) DLT protection 0: Disable, 1: Enable 0 (Disable) 10 (11 th ) Locked rotor detection on start 0: Enable, 1: Disable 0 (Enable) 11 (12 th ) Reserved N/A N/A 12 (13 th ) Lost rotor ride-through protection 0: Enable, 1: Disable 0 (Enable) 13 (14 th ) DLT temperature source 0: From Modbus or Keypad, 1: From Terminal Analog Input 0 (From OEM) 14 (15 th ) Reserved N/A N/A 15 (16 th ) Reserved N/A N/A 16 Quick Start Guide

17 4.2 System control word parameter Pr , containing the system control word, is used to control the drive only in Modbus control mode. To allow for simple drive configurations in Modbus control mode, all drive and compressor functions are enabled/disabled using this single bitwise parameter: Pr Table 4-2 Key to the Control Parameter (the first bit, aka. the least significant bit, is on the right side of the binary number): Pr Bit Name Function Default 0 (1 st ) Start 1: Start 0: No action 0 1 (2 nd ) Controlled shutdown 1: Shutdown the compressor 0: No action 0 2 (3 rd ) Stator heating control 1: Turn on the stator heater 0: No action 0 3 (4 th ) Defrost cycle trigger 1: Trigger the defrost cycle on transition 0: No action 0 4 (5 th ) Reset trips if possible 1: Reset trips on transition 0: No action 0 5 (6 th ) Trip on communication loss 1: Enable the communication watchdog 0: No action 0 Bits 6 to 15 Reserved N/A N/A NOTE When the drive is configured for Modbus control mode (i.e. Pr bit 8=1), the compressor is started by setting Pr bit 1=1; the compressor will continue to run even if Pr bit 1 is set back to 0. The only way to enable the controlled shutdown sequence in Modbus control mode is to set Pr bit 2=1. Drive wiring System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 17

18 4.3 Menu 0 - compressor specific parameters Menu 0 is used to bring together all the compressor specific parameters for easy basic setup of the drive. All of the parameters in menu 0 appear in other menus in the drive (denoted by { }). Where control is via 485 serial communications, a MODBUS address is given for each parameter (assumes 32-bit access). Refer to section 6 of the Drive User Guide for additional details on Menu 0 parameters. Table 4-3 Menu 0 parameters Parameter Range Default Mapping Modbus address (hex) Enable conditions Software system state Condition alerts Condition warnings Trip/Lockout number Configuration control parameter System control word User speed reference in rpm Speed reference after envelope control Final Speed reference Speed feedback Stator heating control mode Condenser pressure (displayed in tenths of a unit) Evaporator pressure (displayed in tenths of a unit) DC Bus Voltage ±VM_DC_VOLTAGE V Drive output frequency ±VM_SPEED_FREQ_ REF Drive output voltage ±VM_AC_VOLTAGE V Drive output power ±VM_POWER kw Total Current ±VM_DRIVE_CURRENT_ UNIPOLAR A Torque producing current ±VM_DRIVE_CURRENT A Accumulated Energy kw ±99.99 kwh Accumulated Energy MW to MWh DLT (Discharge line temperature) Inverter temperature % DLT over temperature fault count Locked Rotor Failure start count Number of soft-start attempts Short cycle count Active EVC Drive trip number Quick Start Guide

19 Last trip time Last trip date Soft-start speed Soft start acceleration Soft-start dwell time Normal running acceleration Normal running deceleration Shut down deceleration Shutdown hold speed Controlled shutdown dwell time Stop deceleration Oil boost threshold speed Oil boost threshold time Oil boost acceleration rate Oil boost deceleration rate Oil boost speed {01.026} Oil boost solution time Oil Boost timer Stator heating wattage Skip Reference Skip reference band Skip Reference Skip reference band Skip Reference Skip reference band Defrost deceleration rate Defrost acceleration rate User defrost speed reference Defrost cycle end dwell time DLT check delay time Locked rotor Idle time Parameter Range Default Mapping Lost rotor ride-through dynamic threshold Modbus address (hex) Lost rotor ride-through constant threshold Short cycle limit Short cycle time Envelope Profile Selection Serial address Drive wiring System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 19

20 Serial mode Serial Baud rate 8 2 NP (0), 8 1 NP (1), 8 1 EP (2), 8 1 OP (3), 8 2 NP M (4), 8 1 NP M (5), 8 1 EP M (6), 8 1 OP M (7), 7 2 NP (8), 7 1 NP (9), 7 1 EP (10), 7 1 OP (11), 7 2 NP M (12), 7 1 NP M (13), 7 1 EP M (14), 7 1 OP M (15) 300 (0), 600 (1), 1200 (2), 2400 (3), 4800 (4), 9600 (5), (6), (7), (8), (9), (10) 8 2 NP (0) (6) Fieldbus Monitor trigger time Unassigned Clone parameters None (0), Read (1), Program (2), Auto (3), Boot (4) Reset comms Reset drive Running log of alerts entry number Running log alert ID number and days and hours Unassigned Security level Menu 0 (0), All Menus (1), Read-only Menu 0 (2), Read-only (3), Status Only (4), No Access (5) EVC Drive software version Out of envelope trip delay time Parameter Range Default Mapping Out of envelope trip delay time for low condensing at power up Modbus address (hex) NOTE All parameters have a 16 bit data size. Depending on the OEM controller being used, the controller might need to subtract '1' from the Modbus addresses listed above in order to access the intended parameter. 20 Quick Start Guide

21 5 PC Tools - HVAC Connect 5.1 Quick start commissioning / start-up using HVAC Drive Connect (V onwards) HVAC Drive Connect is a Windows based software commissioning / start-up tool. HVAC Drive Connect can be used for commissioning / start-up and monitoring, drive parameters can be uploaded, downloaded and compared and simple or custom menu listings can be created. Drive menus can be displayed in standard list format or as live block diagrams. HVAC Drive Connect is able to communicate with a single drive or a network. HVAC Drive Connect can be downloaded from: (file size approximately 100 MB). HVAC Drive Connect system requirements Windows 8, Windows 7 SP1, Windows Vista SP2, Windows XP SP3 Minimum of 1280 x 1024 screen resolution with 256 colours Microsoft.Net Frameworks 4.0 (this is provided in the downloaded file) Note that you must have administrator rights to install HVAC Drive Connect Any previous copy of HVAC Drive Connect should be uninstalled before proceeding with the installation (existing projects will not be lost). Included within HVAC Drive Connect is the Parameter Reference Guide for HVAC Drive Updating firmware If the drive has previously been installed and commissioned then apply the AC mains voltage to the drive. Alternatively the drive's control logic can be powered up out of the box using a 24 Vdc power supply. Refer to the Drive User Guide for additional information on connecting 24 Vdc to the drive. Once the drive has been powered up then start HVAC Drive Connect. Based on the available communication accessories available, select one of the two options below from the 'Project Management' screen to communicate with the drive. 1. Connect an optional USB-to-485 Adaptor to one of the open 485 ports on the drive. Select Scan serial RTU network. Note that no other device is permitted to actively use the other 485 port on the drive as a master. 2. Connect an optional SI-Ethernet option module to the drive and connect to a computer using an RJ45 cable. Select Scan Ethernet network Drive wiring System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 21

22 NOTE HVAC Connect can take up to 10 minutes to locate and connect to the drive. Once HVAC Drive Connect appears to have identified the drive, press the 'Online' icon to begin communicating with the drive. 22 Quick Start Guide

23 If required, obtain the most recent firmware for the drive model and place the file on the computer desktop. Click on the 'Change Firmware' icon from the Dashboard tab. Browse for the file with an '.img' file extension and select 'open'. Click on the 'Next' icon at the top-right corner of the window. Ensure that no power or communication connections are at risk of becoming disconnected and then click on "Start Download" to proceed with updating the drive firmware. Note that it could take approximately 8 to 10 minutes to upgrade the drive via 485; it should take less than 1 minute to upgrade the drive via the SI-Ethernet module. Once HVAC Drive Connect prompts that the upgrade is complete, close out of any messages that have popped up. At this point, HVAC Drive Connect may require the user to re-scan for the drive before communications can resume. Drive wiring System control Keypad Parameters PC Tools - HVAC Connect Quick Start Guide 23

24 5.1.2 Saving / Loading parameters Saving parameters from a drive can be useful for many reasons including the following: Creating a backup of non-default parameters prior to experimenting with parameter value adjustments. Creating a master parameter file that can be used to "clone" subsequent drives as a way to reduce commissioning time. To save a parameter set from the drive, click on the 'Upload to a file' icon and press save. To download a.parfile from a computer into a drive, click on the 'Download file to drive' icon and press open Viewing drive parameters To view the drive parameters, choose a menu by clicking the 'Parameter Listings' icon on the Dashboard tab. HVAC Drive Connect has some useful tools built in to the program. The drive parameters can be compared against the drive default values to show what parameter values have changed from defaults. Alternatively, the drive parameters can be compared against a.parfile located on a computer to show what drive parameter values have changed from the original file. 24 Quick Start Guide

25

26

Optidrive Applications Support Library

Optidrive Applications Support Library Optidrive Applications Support Library Application Note Title AN-ODV-3-038 Related Products Optidrive Eco Overview Level 3 Modbus RTU Control and Register Mapping 1 Fundamental - No previous experience

More information

Optidrive Applications Support Library

Optidrive Applications Support Library Optidrive Applications Support Library Application Note Title AN-ODE-3-038 Related Products Optidrive E3 Overview Level 3 Modbus RTU Control and Register Mapping 1 Fundamental - No previous experience

More information

Copyright: December 2017 Nidec Issue: E

Copyright: December 2017 Nidec Issue: E General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment

More information

Parameter Reference Guide. KBG2 Series. RFC-A Mode

Parameter Reference Guide. KBG2 Series. RFC-A Mode Reference Guide KBG2 Series RFC-A About Reference Guide The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the

More information

Copyright December 2017 Nidec Issue: D

Copyright December 2017 Nidec Issue: D General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment

More information

Copyright: December 2017 Nidec Issue: E

Copyright: December 2017 Nidec Issue: E General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment

More information

Parameter Reference Guide. Unidrive M200. RFC-A Mode. Issue:

Parameter Reference Guide. Unidrive M200. RFC-A Mode. Issue: Reference Guide Unidrive M200 RFC-A About Reference Guide The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the

More information

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1 4/8/2015 52 nd Annual OTCO WW Workshop W/WW Product Overview ACQ550 Slide 1 Drive Basics Why Use Adjustable Speed Drives? Reduced Energy Consumption Improved Process Control / Efficiency Increased Product

More information

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10 AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP 200 480 Volt 1 & 3 Phase Advanced User Guide Revision 1.10 Optidrive P2 Parameter Set Overview 1 This Document is for use with version 1.20 Firmware. Advanced

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor. 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)

More information

4-step Chiller and Heat Pump Controller

4-step Chiller and Heat Pump Controller 4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW

More information

E600 VX01 Installation guide

E600 VX01 Installation guide E600 VX01 Installation guide illuminfx Dimensions 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing

More information

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Service Bulletin SB685 Date: 8/18/2017 Subject: TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Units: All TriPac EVOLUTION Summary: This bulletin updates and

More information

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09 Application Note Title AN-ODE-01 E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/08 1.03 Revised to new format PAE 09/03/09 General This document

More information

ETHERNET/IP & PROFINET MODULE

ETHERNET/IP & PROFINET MODULE 5108 en - 2013.12 / a Ready Stop Run Start Trip Local Reset LCL RMT er w Po n Er 1 2 us k 1 /RX k 2 /RX at Lin TX St Lin TX 2 14702.A r ro 1 give e b s to i l a nu se r a u m d This o the en t ETHERNET/IP

More information

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3.

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3. User Guide Modbus Module For Digistart soft starters Part Number: 477-9-3 Issue: 3 General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent

More information

Macro Guide. Affinity. Model sizes 1 to 6. Building Automation HVAC/R drive. Part Number: Issue: 1.

Macro Guide. Affinity. Model sizes 1 to 6. Building Automation HVAC/R drive. Part Number: Issue: 1. Macro Guide Affinity Model sizes to Building Automation HVAC/R drive Part Number: 0-000-0 Issue: www.controltechniques.com General Information The manufacturer accepts no liability for any consequences

More information

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE INSTRUCTIONS MODBUS TCP MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-800-808-2131 Fax: 1-800-711-1616 www.worldwideelectric.net Product Compatibility This communications module

More information

User Guide. Unidrive M700. Frame sizes 3 to 10. Low voltage DC operation in Elevator Applications. Issue: 1

User Guide. Unidrive M700. Frame sizes 3 to 10. Low voltage DC operation in Elevator Applications. Issue: 1 User Guide Low voltage DC operation in Elevator Applications Unidrive M700 Frame sizes 3 to 10 Issue: 1 Original Instructions For the purposes of compliance with the EU Machinery Directive 2006/42/EC General

More information

ADVANCED OPERATOR PANEL (AOP)

ADVANCED OPERATOR PANEL (AOP) ADVANCED OPERATOR PANEL (AOP) Operating Instructions Issue 04/02 English Contents 1 Warnings and Notes 3 1.1 Special Key Functions 4 2 Applications Examples 4 2.1 Single drive control using the AOP 4 2.2

More information

Opal Pro to DeviceNet. Opal Pro MS6 SERIES. DeviceNet Interface Users Manual. Revision Page 1

Opal Pro to DeviceNet. Opal Pro MS6 SERIES. DeviceNet Interface Users Manual. Revision Page 1 Opal Pro MS6 SERIES DeviceNet Interface Users Manual Revision 1.01 Page 1 Page 2 FOR YOUR SAFETY Only qualified personnel should install this equipment, after first reading and understanding all the information

More information

3GV M Modbus RTU Register Map

3GV M Modbus RTU Register Map Application Note AN-ODP- 38 3GV M Modbus RTU Register Map Author: Ning Xu, Invertek Drives Ltd Revision: 2.21 15 June 2007 General This document details the Modbus RTU memory mapping implemented in Optidrive

More information

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015 ESC 201 Installation and Operating Instructions Manual SG-0002-03 Jan 2015 Table of Contents 1.0 FUNCTIONS... 5 2.0 FEATURES... 5 3.0 ESC 201 DESCRIPTION... 6 4.0 GENERAL OPERATIONS... 6 4.1 MANUAL MODE

More information

SM-I/O Plus. Solutions module for UNIDRIVE SP. User guide. This manual is to be given to the end user. Réf en / a

SM-I/O Plus. Solutions module for UNIDRIVE SP. User guide. This manual is to be given to the end user. Réf en / a M Réf. 3952 en - 09.2005 / a T2 digital I/O 1 state T2 output select??.?? X.09 X.31 0 1 x(-1)??.?? This manual is to be given to the end user 2 T2 digital I/O 1 Positive logic select 1 0 X.29 X.11 x(-1)

More information

Firmware Manual - EC Series Drives

Firmware Manual - EC Series Drives 1 Firmware Manual - EC Series Drives Doc Ver 1.01 Firmware ver: EC series drives For installation details refer to Hardware Manual Safety: Read safety instruction in hardware manual before installation

More information

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features Table of Contents Drive Features... 1 Drive Specifications... 2 Certifications... 3 Installation - Drive Dimensions... 3 Motor Dimensions (mm)... 4 Drive Mounting... 4 Wiring... 5 I/O Terminals... 9 Menu...

More information

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00 AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP 200 480 Volt 1 & 3 Phase Advanced User Guide Revision 2.00 Optidrive P2 Advanced User Guide Rev 2.00 Optidrive P2 Parameter Set Overview 1 This Document

More information

Optidrive VTC Modbus RTU Register Map

Optidrive VTC Modbus RTU Register Map Application Note AN-VTC- 39 Optidrive VTC Modbus RTU Register Map Author: Ning Xu, Invertek Drives Ltd Revision: 2.21 6 September 2006 General This document details the Modbus RTU memory mapping implemented

More information

Opal Pro AB Ethernet IP. Opal Pro MS6 SERIES. AB Ethernet IP Interface Users Manual. Revision Page 1

Opal Pro AB Ethernet IP. Opal Pro MS6 SERIES. AB Ethernet IP Interface Users Manual. Revision Page 1 Opal Pro MS6 SERIES AB Ethernet IP Interface Users Manual Revision 1.02 Page 1 Page 2 FOR YOUR SAFETY Only qualified personnel should install this equipment, after first reading and understanding all the

More information

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137 MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137 Revision History Page 1 of 11 Date ECN Rev Description By 09/01/10 EC34869 A Initial Release D. Stahl 07/14/11 EC39745 B Updated

More information

E2 Modbus RTU Register Map

E2 Modbus RTU Register Map Application Note AN ODE 01 E2 Modbus RTU Register Map Author: Peter Evans, Invertek Drives Ltd Revision: 1.02 11 June 2008 Software Version: 1.02 General This document details the Modbus RTU memory mapping

More information

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions GE AF-600 FP TM Fan & Pump Drive (230V to 60HP, 460/575V to 125HP Operating Instructions Safety Safety WARNING HIGH VOLTAGE! Frequency converters contain high voltage when connected to AC mains input power.

More information

Keep all manuals as a product component during the life span of the product. Pass all manuals to future users / owners of the product.

Keep all manuals as a product component during the life span of the product. Pass all manuals to future users / owners of the product. KC1 Quick Start Edition: June 2012, Revision A Valid for Hardware Revision A Patents Pending Part Number 903-400000-00 Keep all manuals as a product component during the life span of the product. Pass

More information

PROFINET MODULE. Communications module. User Guide. This manual is to be given to the end user en / a. Power. Error. Status.

PROFINET MODULE. Communications module. User Guide. This manual is to be given to the end user en / a. Power. Error. Status. 5201 en - 2014.09 / a Stop Ready Run Start Trip Reset Local LCL RMT Power This manual is to be given to the end user Error Status Link 1 TX/RX 1 Link 2 1 2 TX/RX 2 14702.A PROFINET MODULE Communications

More information

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters FU+ New Generation of Intelligent Refrigeration Inverters Efficient and Energy-saving Control of Refrigeration Compressors and Condenser Fans www.frigokimo.com Effective speed control saves energy and

More information

BACnet Flow Controller for Fan Filter Units

BACnet Flow Controller for Fan Filter Units MANUAL SERVICE + INSTALLATION BACnet Flow Controller for Fan Filter Units BFC Series v300 Issue Date: 08/23/17 2017 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General

More information

User Guide. Cloning interface small option module for Unidrive and Commander GP. Part Number: Issue Number: 3

User Guide. Cloning interface small option module for Unidrive and Commander GP. Part Number: Issue Number: 3 User Guide UD55 Cloning interface small option module for Unidrive and Commander GP Part Number: 0460-0095 Issue Number: 3 General Information The manufacturer accepts no liability for any consequences

More information

P3-RS Remote Slave Module

P3-RS Remote Slave Module P3-RS Rack with CPU Module Racks with P3-RS Modules The P3-RS is a full-featured, highperformance, Remote Slave module. Features include a line x 0 charactor LCD display and five communications ports

More information

AE R6 July 2018 Electronic Unit Controller

AE R6 July 2018 Electronic Unit Controller July 2018 Electronic Unit Controller TABLE OF CONTENTS Safety... 3 Safety Instructions... 3 Safety Icon Explanation... 3 Instructions Pertaining to Risk of Electrical Shock, Fire, or Injury to Persons...

More information

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

Safety Instructions 1-1 Avoid unintended Start General Description 2-2 Contents Contents 1 Safety and precautions 1-1 Safety Instructions 1-1 Avoid unintended Start. 1-1 2 Introduction 2-1 General Description 2-2 3 Supported Configuration 3-1 Introduction 3-1 Fixed-speed

More information

Graphical User Interface V1.0.3

Graphical User Interface V1.0.3 Graphical User Interface V1.0.3 Application User Guide 2015 MCI Solutions. All rights reserved. 240815-01 www.mcisolutions.ca Page ii Getting Started Table Of Contents Introduction.................................................

More information

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04 GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04 Instruction Manual D2-3387-4 The information in this manual is subject

More information

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE INSTRUCTIONS MODBUS RTU MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-8-88-2131 Fax: 1-8-711-1616 www.worldwideelectric.net Product Compatibility This communications module is suitable

More information

Unidrive M400. Control Quick Start Guide

Unidrive M400. Control Quick Start Guide Control Quick Start Guide Unidrive M400 Manufacturing Automation drive Fast set-up and diagnosis with real-text display, plus integrated Machine Control Studio based PLC Part Number: 0478-0267-04 Issue:

More information

6-Channel Monitor. Installation and Operation Manual

6-Channel Monitor. Installation and Operation Manual 3211 Fruitland Ave Los Angeles, CA 90058 Catalyst Monitor 6-Channel Monitor Version 2 Installation and Operation Manual Rev. H P/N145F-12964 PCO - 00009743 (c) Copyright 2015, Barksdale, Inc. All Rights

More information

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs

More information

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD lnvertek Drives.com ft ct,ve ELECTRICAL SUPPLIERS LTD OptidriveE2 Technical Product Guide 1.1 OVERVIEW Range IP20 IP66X (NON SWITCHED) IP66Y (SWITCHED) Supply Voltage Range Power Range 110 115 + / 10%

More information

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017

More information

FREQUENCY CONVERTER FC102 (QUICK GUIDE)

FREQUENCY CONVERTER FC102 (QUICK GUIDE) FREQUENCY CONVERTER FC102 (QUICK GUIDE) INSTALLATION AND MAINTENANCE Content Page Safety instructions 2 IT system 3x230VAC 2 Connections 3 Control unit (LCP) 4 Manual operation 4 Reverse the direction

More information

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Issue 06

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Issue 06 AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP 200 480 Volt 1 & 3 Phase Advanced User Guide Issue 06 About this Advanced Technical Manual 1 Revision History Issue Note Section Date 1.00 First Release

More information

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW. CENTRIFLOW PUR 3D (A, PLUG B, C, D) FAN GMPM FC101 AND SLIDE IN FREQUENCY ROTOR CASSETTE CONVERTER QUICK GUIDE FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS

More information

Application Engineering B U L L E T I N. AE R1 November Intelligent Store Discus V1.0 Operators Manual

Application Engineering B U L L E T I N. AE R1 November Intelligent Store Discus V1.0 Operators Manual Application Engineering B U L L E T I N AE8-1337 R1 November 2006 Intelligent Store Discus V1.0 Operators Manual The Intelligent Store Discus product line has recently been introduced on 2D, 3D, and 4D

More information

Quantum HD Release Notes

Quantum HD Release Notes Quantum HD Release Notes OS Version 10.17 Released 7-14-2014 To upgrade to OS version 10.17 directly the current OS version must be 10.13 through 10.16. To check the current OS version on the Quantum HD

More information

Installing VO2 Analog Output Boards

Installing VO2 Analog Output Boards Chapter 3-6 VO2 Description and Identification Installing VO2 Analog Output Boards The VO2 Variable Output board provides an AKC 55 system with 2 variable outputs for control of loads like variable speed

More information

Baltimore Aircoil Company

Baltimore Aircoil Company Baltimore Aircoil Company VFD Startup Guide TABLE OF CONTENTS: A. Verifying Power and Control Wiring...1 B. Setting the VFD Parameters...2 C. Reentering Startup Wizard After Initial Setup...5 D. Starting

More information

Instructions. Modbus RTU Card (WSIQ-COM-MB)

Instructions. Modbus RTU Card (WSIQ-COM-MB) Instructions (WSIQ-COM-MB) Contents 1 Warnings... 2 2 Important User Information... 2 3 Installation... 2 4 Operation... 3 5... 4 6 Specifications... 15 Product Compatibility The is suitable for use with

More information

System User Manual. AKC 55 Rack Controller

System User Manual. AKC 55 Rack Controller System User Manual AKC 55 Rack Controller This User s Manual contains installation, start-up, and operating instructions for all parts of the Danfoss AKCESS System. Use the Table of Contents to find the

More information

User Guide Regenerative & Non-Regenerative Digital DC Drives 5 to 1000 HP

User Guide Regenerative & Non-Regenerative Digital DC Drives 5 to 1000 HP User Guide Regenerative & Non-Regenerative Digital DC Drives 5 to 1000 HP Quantum III The drive stop and start inputs should not be relied upon alone to ensure the safety of personnel. If a safety hazard

More information

Profinet Module. User Manual. Contents

Profinet Module. User Manual. Contents User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 7 6 Packet Structures... 8 7 Network Design... 16 8 Specifications...

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5

More information

RST INSTRUMENTS LTD.

RST INSTRUMENTS LTD. RST INSTRUMENTS LTD. VW0420 Analog VW Interface Instruction Manual Ltd. 11545 Kingston St Maple Ridge, BC Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005 Email: Info@rstinstruments.com i VW0420

More information

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2 USER MANUAL MPI-1500/2000/3000/4000/6000 Series GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2 WWW.MPPSOLAR.COM WARNING: ONLY A CERTIFIED ELECTRICIAN OR TRAINED ASSEMBLING PROFESSIONAL SHOULD OPEN OR INSTALL

More information

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide This guide is intended to provide basic information required in order to set-up a drive to run a motor. Please refer to the Unidrive M200 / M20 User Guide which is available to download from www.controltechniques.com/user

More information

Ethernet/IP Module. User Manual. Contents

Ethernet/IP Module. User Manual. Contents User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 8 6 Packet Structures... 9 7 Network Design... 18 8 Specifications...

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

SI3300. user and installation manual. 4-20mA/DC-Digital Display

SI3300. user and installation manual. 4-20mA/DC-Digital Display SI3300 4-20mA/DC-Digital Display The SI3300 is a member of the SI3000 Readout Family. All members of the family are marked SI3000 on the front panel. This manual is specifically for the SI3300 Model with

More information

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean

More information

OPTIDRIVE PLUS 3 GV 3 rd Generation Vector Control AC Variable Speed Drive kW

OPTIDRIVE PLUS 3 GV 3 rd Generation Vector Control AC Variable Speed Drive kW OPTIDRIVE PLUS 3 GV 3 rd Generation Vector Control AC Variable Speed Drive 0.37-160kW Optidrive Plus 3 GV is the natural evolution of the Optidrive family adding ultimate motor control to established Optidrive

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs QUICK START GUIDE Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com

More information

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone.

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone. ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE ATM ACC1 Table of Contents Safety Precautions... 3 Overview... 4 Specifications... 4 Installation... 5 Control Console Operation... 9 2 Advanced

More information

GE Power Management. MMII Intelligent MCC Controller

GE Power Management. MMII Intelligent MCC Controller A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance. Presentation Overview 6 Applications 6 Protection and Control

More information

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95 Part 1 - GENERAL ASEA BROWN BOVERI ABB Industrial Systems Inc. Standard Drives ACH500-06E Effective 6/1/95 Sample Specification for Adjustable Frequency Drives (2 to 400 HP) for Variable Torque Applications

More information

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC Software Start-Up and Reference Manual D2-3416-2 GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, 30-100 HP, 230V AC Version 6.04 Important User Information Solid-state equipment has operational

More information

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4 LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4 Instruction Manual D2-3410-7 The information in this manual is subject to change without

More information

IM-pAC. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp. Model sizes A, B and C

IM-pAC. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp. Model sizes A, B and C Getting Started Guide IM-pAC AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp Model sizes A, B and C Part Number: 0472-0056-04 Issue: 4 General The manufacturer accepts

More information

310SV SINGLE VALVE GOVERNOR

310SV SINGLE VALVE GOVERNOR 310SV APPLICATION The 310SV is a fully integrated and configurable controller designed to startup, run, and protect single-valve steam turbines. The controller is designed to control steam turbines driving

More information

SPX 1hr product overview Eaton Corporation. All rights reserved.

SPX 1hr product overview Eaton Corporation. All rights reserved. SPX 1hr product overview 2012 Eaton Corporation. All rights reserved. Eaton Product Offering Machinery OEM Drives DE1, DC1, DE1, DA1, M-Max HVAC Drives H-Max 0.25HP 25HP 1HP 250HP General Purpose Industrial

More information

MCH Series Drives Metasys N2 Communications Guide

MCH Series Drives Metasys N2 Communications Guide MCH Series Drives Metasys N2 Communications Guide About These Instructions This documentation applies to the use of an MCH Series Variable Frequency Drive with Metasys N2 protocol and should be used in

More information

Genset control and protection with safety system

Genset control and protection with safety system APPLICATION NOTES Generator Protection Unit, GPU-3 APPLICATION NOTES Genset control and protection with safety system Application description Functional description Wiring I/O lists Basic setup Flowcharts

More information

TS110 DISPLAY MANUAL Pro Refrigeration, Inc

TS110 DISPLAY MANUAL Pro Refrigeration, Inc TS110 DISPLAY MANUAL Pro Refrigeration, Inc ii Pro Refrigeration, Inc Table of Contents 1 Preface ill Disclaimer.............................. ill Manufacture Information....................... ill Customer

More information

Vacon HVAC100 Commissioning Guide

Vacon HVAC100 Commissioning Guide Vacon HVAC100 Commissioning Guide INDEX 1. Glossary of terms 2. Wiring diagrams 3. Set up procedures a. Motor settings input b. Low level start, analogue input speed reference in AUTO position. Low level

More information

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1 BrewTroller Phoenix Owners Manual Updated - March 14, 2016 BREWTROLLER PHOENIX 1 2016 BrewTroller All Rights Reserved. Product warranty or service will not be extended if: (1) the product is repaired,

More information

Athena Series RMC Hot Runner Controller Configuration and Operation Manual

Athena Series RMC Hot Runner Controller Configuration and Operation Manual Athena Series RMC Hot Runner Controller Configuration and Operation Manual Athena and CompuStep are registered trademarks, and Multi-Comm and SafeChange are trademarks of Athena Controls, Inc. MODBUS is

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

User Guide SE73-PROFIBUS-DP. Commander SE. Part Number: Issue Number: 4.

User Guide SE73-PROFIBUS-DP. Commander SE. Part Number: Issue Number: 4. EF User Guide SE73-PROFIBUS-DP Commander SE Part Number: 0452-0057-04 Issue Number: 4 www.controltechniques.com Safety Information The option card and its associated drive are intended as components for

More information

DC1 Series 1 Hour Product Overview Eaton Corporation. All rights reserved.

DC1 Series 1 Hour Product Overview Eaton Corporation. All rights reserved. DC1 Series 1 Hour Product Overview Agenda PowerXL Family DC1 product overview Applications drivesconnect DC1 demo Programming Sales fuel Tools and resources Support and services 2 Eaton Product Offering

More information

SMART PROGRAMMABLE RELAYS

SMART PROGRAMMABLE RELAYS CONTROL LOGIC SMART PROGRAMMABLE RELAYS c3controls line of compact programmable relays are integrated, and ready to use, with a wide range of programmable functions. With up to 250 lines of ladder logic

More information

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1 FSO Webnair FSO Safety Functions Module February 11, 2015 Slide 1 Competence Requirements for ABB Commissioner / Service Engineer of ACS880 Drives with FSO The integrated Safety Function Module (FSO; option

More information

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V) E510 Compact Drive IP 20/ NEMA 1 0.5-40 HP (230V) 1-75 HP (460V) Control Mode Application & Selection Guide The E510 compact AC Drive is an easily configurable product that controls many motor driven applications.

More information

POWERWISE INDAC SETUP MANUAL

POWERWISE INDAC SETUP MANUAL POWERWISE INDAC SETUP MANUAL REVISION: 2.2 INDAC & EMONITOR GATEWAY An installation guide for the PowerWise indac. 2013 PowerWise, Inc. This manual may contain proprietary information about the product

More information

Gas Controller System DGC-06

Gas Controller System DGC-06 Page 1 May 2016 Measuring, warning and controlling device series for toxic, combustible and refrigerant gases and vapours. The gas controller series DGC-06 is designed in accordance with the standard EN

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

Optional Accessories 6 2

Optional Accessories 6 2 Accessories Chapter 6 Table of Contents Optional Accessories 6 2 Finger Guards 6 2 Remote Touchscreen 6 3 RJ45 to RJ12 Adapter 6 5 Serial Modbus Communication Splitter 6 5 Communication Modules 6 7 Replacement/Spare

More information

M2500 Engine Controller Configuration Manual

M2500 Engine Controller Configuration Manual M2500 Engine Controller Configuration Manual Revision: 08-04-2011 Page 1 Contents 1 Preface... 4 2 Configuration from front panel... 5 2.1 Engine Controller Configuration... 6 2.1.1 RPM settings... 6 2.1.2

More information

Warranty. Warning. Copyright. Contact Us

Warranty. Warning. Copyright. Contact Us M-6026U-32 16-channel Universal Input and 16-channel Universal Output Version: 1.0.0 Date: Dec. 2017 Edited by Horse Chien M-6026U-32 User Manual Version 1.0.0 Dec. 2017-1 - Warranty All products manufactured

More information

Communications Quick-Start Guide

Communications Quick-Start Guide WEG CFW300 AC Drives Serial Communications Quick-Start Guide NOTE: This Quick-Start guide is intended for the sole purpose of establishing communications connections between WEG CFW300 AC Drives and AutomationDirect

More information

Metaphase DDC-3. Technologies USER MANUAL. Version 7.X August metaphase-tech.com. pg. 1

Metaphase DDC-3. Technologies USER MANUAL. Version 7.X August metaphase-tech.com. pg. 1 USER MANUAL Version 7.X August 2014 pg. 1 Overview Digital Dimming Controller () provides 0-10V voltage dimming control of three independent LED loads in increments of 0.1V. The may be remotely controlled

More information

Control Quick Start Guide. Unidrive M200/201. Flexible machine integration through communications. Part Number: Issue: 3

Control Quick Start Guide. Unidrive M200/201. Flexible machine integration through communications. Part Number: Issue: 3 Control Quick Start Guide Unidrive M200/201 Flexible machine integration through communications Part Number: 0478-0282-03 Issue: 3 Original Instructions For the purposes of compliance with the EU Machinery

More information

Control system for rotary heat exchanger EQRB, L=3,4

Control system for rotary heat exchanger EQRB, L=3,4 Installation instructions, drive system EQRB, L=3.4 sizes 005-072 General description A speed controlled drive system specifically adapted to drive rotary heat exchangers. No tuning is necessary. All control

More information