Research, Inc. About This Getting Started Guide

Size: px
Start display at page:

Download "Research, Inc. About This Getting Started Guide"

Transcription

1

2 Research, Inc About This Getting Started Guide makes no warranty on the accuracy of the information contained in this getting started guide and accepts no liability for its use. The information contained in this getting started guide remains the property of It is provided in good faith for the operation and servicing of this product. We reserve the right to take legal action where this information is divulged to third parties without our written consent or in circumstances that may cause us commercial harm. The operation of this equipment requires training and experience in electric meter testing. The information in this getting started guide is designed to supplement existing knowledge and experience already attained and practiced by journeyman-level meter test technicians. Novice meter test technicians should not attempt to operate this equipment without first gaining the basic knowledge of meter testing and the application of meter testing equipment from a certified training course. Copyright 2012 Radian Research reserves the right to change any information in this document without notice.

3 Table of Contents About This Getting Started Guide Product Introduction and Specifications Product Overview Optional Accessories Product Features RB-20 Portable Test System RB-2X Embedded Winboard Software Safety Information General Safety Summary Symbols Found on the Equipment Conventions Used in this Getting Started Guide Specifications RB-2X Bantam Plus RB-2X I/O Connection Operation Preparation Getting Started Thank You for your Purchase Preparing Equipment for Use Registering Your Equipment Operational Considerations Operational Considerations for Testing Electro-mechanical Meters Assembling the RB-MOUNT Testing Mechanical Meters using the RB-MOUNT RB-BPH Optional Carry Harness Attachment RB-TSBR1 Optional Current Transformer Test Product Features RB-2X Components and Controls Top Panel Touch Screen Display Operations Overview Setting the Bantam Plus... 35

4 4.1.1 Powering on the Unit Powering on the Unit in the Field Conducting a Meter Test with the Bantam Plus Integrated Socket Meter Test using Meter Test Adapter (RB-MTA) option Creating a Transducer Test Sequence Conducting a Transducer Test RB-2X Administration Application Administration Application Overview Edit Form Defaults Edit Test Sequences view/edit Test Results Edit Customer List Edit Data View & Import Export Options Edit Drop Down Code Edit Barcode Edit Meter Setup Options RB-2X Utilities Application Utilities Overview Standards Compare Run Sinewave Editor External RD Comm Remote Control Desktop Settings Remote Assistant Updates Back-up and Restore RB-2X Site Information Application Site Information Application Overview Edit Site Information Load Site Information Site Report Routine Maintenance and Service Contact Information Routine Maintenance Bantam Plus Getting Started Guide 4

5 8.3 Service Service Warranty Service After-Warranty Service Standards Compare and use of the RB-SCA Option Updating Bantam Plus Firmware Helpful Documentation and Resources Table of Figures Figure 1 RB-2X Bantam Plus Portable Test System... 7 Figure 2 WATT-Net and Windboard Software Data Transfer Figure 3 RB-2X Bantam Plus Portable test system rear panel Nameplate containing equipment serial number Figure 4 RB-2X Bantam Plus Portable Test System Cooling Vents Figure 5 Bantam Plus Main Menu Screen Figure 6 Touch Screen Keyboard. 34 Figure 7 Numeric Screen Keyboard 34 Figure 8 Windows Screen Keyboard...34 Figure 9 Bantam Plus Screen Tour. 37 Figure10 Bantam Plus Meter Test Screen...38 Figure 11 Bantam Plus Meter Run Testing Screen Figure12 Meter Test Adapter RB-MTA...41 Figure 13 Setting the Form to Match MTA Adapter Requirements...41 Figure 14 Select Voltage routing for RB-MTA Adapter Form Figure 15 RB-2x Administration View Figure 16 RB-2x Utilities Application View 52 Figure 17 Site Information Application View..54 Figure 18 View of the Meter Test screen with the Data View enabled to view or edit meter information.. 55 Figure 19 Removable Socket Liners Bantam Plus Getting Started Guide 5

6 About This Getting Started Guide The RB-2X Bantam Plus Portable Test System is designed as a stand-alone meter test system. The product functionality can be extended through use of optional test adapters (see section 1.1) to accommodate different meter and CT test applications. Use this getting started guide for the RB-2X Bantam Plus Portable Test System to perform the tasks shown below. Test Meter Accuracy Perform a Standards Compare. Edit Meter Test Forms and Assign Operator Profiles Read results Transfer Meter Measurement data to an external controller. 1 Product Introduction and Specifications This chapter provides an introduction to the RB-2X Bantam Plus Portable Test System and contains the following sections: 1.1 Product Overview 1.2 Optional Accessories 1.3 Product Features 1.4 Safety Information 1.5 Specifications 1.1 Product Overview The Bantam Plus Portable Test System is designed for fast and accurate testing of electricity meters. The Bantam Plus combines advanced capabilities of an automated meter socket, the accuracy of a Radian reference standard as well as the embedded Winboard automated test software to provide a lightweight, easy-to-use test system Bantam Plus Getting Started Guide 6

7 The RB-2X Bantam Plus Portable Test System consists of the main components shown below in Figure 1. Automated Meter Test Socket Sensor Pro Infrared and Visible Light optical sensor Interface panel to access external sensors, computer peripherals & options. Touch Screen color display Status Indicators Sound control keyboard Figure 1 RB-2X Bantam Plus Portable Test System Bantam Plus Getting Started Guide 7

8 1.2 Optional Accessories Optional accessories and routine maintenance kits are available for the Bantam Plus these include the following: RB-MSA RB-MTA RB-MTA-BN RB-MTA-DB RB-FPC Meter Socket Safety Power Adapter Simply pull the meter and insert the safety adapter into the exposed meter socket. Adapter faceplate voltage banana sockets provide easy access to service voltage. Meter Test Adapter An assembly that plugs into the Bantam Plus meter socket and delivers voltage and current (20 Amps max) to the meter test socket.(see Section 4.2.2) Two further optional Meter Test Adapter cables are available each terminated with 4 mm banana plugs (RB-MTA-BN) and Duckbill adapters (RB-MTA-DB) RB-2x Field Power Cable An eight foot length of three core cable terminated with alligator clips and banana plugs to connect to meter socket service volts. RB-IRDS IR /Visible LED/Laser Disk Sensor, Band Mount The most versatile three in one meter pulse sensor assembly enables meters to be tested in the socket. RB-OPTOCOM OPTOCOM Optics Kit Port 1 Used for meters that require communication via Optocom interface Bantam Plus Getting Started Guide 8

9 RB-MOUNT Frame mount for Mechanical meter orientation and wall mount capability. See Section for assembly and use. RB-MECH 90 Degree Adapter for mechanical meters RM-1S The RM-1S Remote Reset Switch is a normally-closed push button switch. The push-button has a tactile feel to provide instantaneous feedback of switch actuation. RB-MAG Magnetic Mount Optics Kit RB-BPH Back Pack carry harness. See Section RB-BAG Nylon Accessories Bag 12(l) x 8(h) x 5(w) inch Bantam Plus Getting Started Guide 9

10 RB-KYZIO Advance I/O KYZ Breakout Cable Connects to Bantam Plus KYZ port. RB-BARCODE Serial Barcode Scanner Collect Meter Faceplate information and run meter tests automatically from a barcode scanner. RB-SCA RB-2x to RD-2x Standards Compare Adapter Used to interface with an external RD for calibration purposes. See Section for details on using the RB-SCA for Standard Compare function. RB-SMK RB-2x Socket Maintenance Kit Contains pack of six field replacement socket assemblies and one Torx drive. RB-SCRN RB-2x Replacement Screen Shield Damaged or badly scratched screen protectors are field replaceable. RB-TSBR1 RB-TSJ Test Switch Interface Adapter with Burden and Ratio Testing An adapter that plugs into the Bantam meter socket. Provides access to clamp probes and direct secondary current for CT measurement. Test Switch Current Jumper Kit Bantam Plus Getting Started Guide 10

11 1.3 Product Features RB-2x Portable Test System The RB-2x Bantam Plus Portable Test System offers the following features: Integrated automated meter test socket. Integrated pulse sensor. 3 Phase Test Current Output: 0.1 to 50 Amps. Phase control: in 0.05 steps. Synthesized Voltage Output: 69 V to 480 V. Integrated PC controller running Winboard software. Supported Meter Forms - 1S, 2S, 3S, 4S, 5S, 6S, 8S (electronic), 9S, 10S, 12S, 13S, 14S, 15S, 16S, 25S, 26S, 29S, 35S, 36S, 45S, 46S, 56S, 66S, 96S Optional CT, Burden testing. Lightweight RB-2X Embedded Winboard Software The RB-2X Winboard Automated software is used to run tests, assign sensors, set meter form test sequences and view and store test results. The RB-2X Winboard Automated Software offers the following features: Touch Screen interface USB and Ethernet Interface Create/Edit test sequences for meter forms Align Optics Standards Compare test routines Storage capacity is limited by the installed 60GByte solid state hard drive. Create/Edit test reports Maintain customer records Bantam Plus Getting Started Guide 11

12 1.4 Safety Information Review the information in this section to avoid injury and prevent equipment damage. The Bantam Plus was designed with safety in mind. The RB-2X socket will not energize unless a meter is first installed. An Interlock switch will disable the sources should a meter inadvertently be removed from the socket General Safety Summary! WARNING The operation of this equipment requires training and experience in electric meter testing. The information in this getting started guide is designed to supplement existing knowledge and experience already attained and practiced by journeyman-level meter test technicians. Meter Technicians classified as beginners should not attempt to operate this equipment without first gaining the basic knowledge of meter testing and the application of meter testing equipment from a certified training course. Operation of this equipment involves high voltage. Always wear the appropriate personal protective equipment and follow all safety precautions specified for high voltage activities. Follow proper grounding techniques when using this equipment. Follow all safety guidelines contained in this getting started guide.! CAUTION Do not use this equipment for any purpose other than for which it was designed. Do not operate the equipment outside of the environmental conditions specified in this getting started guide. Do not operate this equipment with covers or panels removed. Keep equipment surfaces clean and dry. Handle the RB-2X Bantam Plus Portable Test System with care; it is a precision instrument. Inspect the equipment before each use. Do not use the equipment if damage is observed. Use only cables provided by Bantam Plus Getting Started Guide 12

13 1.4.2 Symbols Found on the Equipment The following safety symbols appear on the RB-2X Bantam Plus Portable Test System: Danger of electrical shock. Warning: Refer to Getting Started Guide or Operations Manual Conventions Used in this Getting Started Guide The following conventions are used in this getting started guide to highlight important information:!! WARNING CAUTION NOTE Indicates an imminently hazardous situation that can result in death or a serious injury. Indicates a potentially hazardous situation that can result in an injury or equipment damage. Indicates important information you should review before proceeding Bantam Plus Getting Started Guide 13

14 1.5 Specifications RB-2X Bantam Plus Operational Supply voltage Test current 90 to 300VAC, 60 Hz Phase A to 50 A (limited to 20 Amp when using optional RB- MTA test adapter) Accuracy RB-20: 0.04%, RB-21: 0.02% Physical Size Weight Warranty Height: 12.6 in (320 mm) Width: 10.2 in (260 mm) Length: 20.4 in (520 mm) 30 lbs (14.29 kg) 2-year warranty against defects in material or workmanship; care plans are available to extend warranty Electrical Protection Line power: 5 A Breaker Environmental Temperature range Relative humidity Shock and vibration Water resistance 10º to 50º C (4º to 122º F) operating, 20º to 70º C (-4º to 158º F) Storage 5 95% non-condensing Any which is nondestructive IP20 Supplied Cable Length Cable type 10 ft RB-SPC Shop Power Cable & RB-FPC Field Power Cable terminated with alligator clips Two wire plus safety ground Bantam Plus Getting Started Guide 14

15 1.5.2 RB-2X I/O Connection The I/O connection panel contains three different connectors, each suited to a particular type of optics for external meter test. NOTE Pulse Port 2 is shared between the onboard sensor and any external sensor connected to Port 2. The onboard sensor Port 2 is factory default sensor for the factory default test sequence unless the test sequence is changed to reflect Optics Port 1 or Port 3. The factory default sensor port can be changed within the Administration application. Port 1 Is reserved for an Optocom* Optics (Model RB- Optocom) cable. Optocom Optics allows the operator to not only detect pulses from solid state meters, but also allows the operator to program the meter without changing the optical head. *Optocom is a registered trade mark of Optocom Corporation. Port 2 Port 3 A REDEL connector is reserved for optical accessories including magnetic mount and band mount optics such as the RB-MAG and RB-IRDS A BNC connector reserved for an optional click-switch adapter RB-CLICK or an optics sensor with BNC termination such as RM-1H or RM-1Hv. The BNC connector is also used when conducting a standards compare test. AUX The AUX port is designed for connection to optional socket adapters including the RB-TSBR1 CT Ratio & Burden adapter Bantam Plus Getting Started Guide 15

16 Advanced I/O This connector is assigned for testing meters with KYZ (Model RB-KYZ10). The Advanced I/O connector provides many capabilities for the testing of solid state meter. It can accommodate up to six Form A contact inputs or four Form C and two Form A contact inputs. For outputs, it has one programmable output allowing 0.01 to 40 seconds between contact transitions and a quantity of pulses (1 to 4094) to output. In addition two outputs can be software set high or low. There is also an unregulated 12VDC output. The following illustration depicts the connection diagram of the advanced I/O connector. IOIOIO A serial port used for external peripherals and options including bar code readers. USB Two USB connectors are available for use with peripherals including memory drives, remote keyboard or mouse, wireless adapters, etc. Ethernet 10/100 Ethernet connection that can be used to connect the Bantam Plus to a local area network Bantam Plus Getting Started Guide 16

17 2 Operation Preparation This chapter provides information on preparing to use your RB-2X Bantam Plus Portable Test System and contains the following sections: 2.1 Getting Started 2.2 Operational Considerations 2.1 Getting Started Thank you for your purchase Thank you for purchasing this quality product. Radian reference standards are recognized throughout the world for their unparalleled accuracy, precision, and stability. We have taken every effort to ensure that your RB-2X Bantam Plus Portable Test System reaches you in perfect condition. Your satisfaction is very important to us, and your continued loyalty is greatly appreciated. If for any reason your Radian product does not meet your expectations of exceptional performance, please contact your sales representative or Radian Research, Inc Fortune Drive Lafayette, IN USA Tel: (765) Fax: (765) Website: Bantam Plus Getting Started Guide 17

18 2.1.2 Preparing Equipment for Use Follow these steps to prepare your RB-2X Bantam Plus Portable Test System for use. 1. Unpack and inspect: Carefully remove the equipment from the packaging, and check for any signs of damage. NOTE If you observe any damage to the equipment, immediately notify the carrier and your sales representative. 2. Verify the contents: The following items are included in your shipment: o RB-2X Bantam Plus o RB-SPC-10 Shop Power cord and RB-FPC-10 Field Power cable terminated with alligator clips. o Carry Handle with Folding Cover o WATT-Net PC Software (Base) CD and Getting Started Guide ( see Figure 2) o Calibration report(s) o Bantam Plus Getting Started Guide o Optional accessories (maybe packaged separately) (see Section 1.2 ) Bantam Plus Getting Started Guide 18

19 3. Information about your equipment software: Your new Bantam Plus is shipped with Winboard software installed. In addition, the Bantam Plus will arrive with a WATT-Net PC Software (Base Version) CD. When installed on an external PC WATT-Net can be used for import/export data management. This base software is supplied with generically define fields. If you wish to customize the fields or are already using WATT-Net within your organization you may purchase optional customization packages. For more information on customization contact your Radian representative or Radian directly at NOTE If you intend to purchase optional software database customization this should be done before you begin to export data from your Bantam Plus. Integrating export data collected post optional database customization may result in lost data. (see section ) Figure 2 WATT-Net and Winboard Software Data Transfer Bantam Plus Getting Started Guide 19

20 4. Register your equipment (see Section 2.1.3, Registering Your Equipment) to: Activate the equipment warranty. Receive firmware and software updates as well as product application notes from NOTE You must register your equipment at to activate the twoyear equipment warranty. If you do not activate the warranty, the warranty period is limited to one year Bantam Plus Getting Started Guide 20

21 2.1.3 Registering Your Equipment Follow these steps to register your RB-2X Bantam Plus Portable Test System: 1. Navigate to 2. Complete the online form. The model number is either RB-20 or RB-21 and is found on nameplate. The serial number can be found on the nameplate as shown in Figure 3. ON/OFF Double pole 5 Amp Breaker Switch Line & Ground Input, 300 VAC max. Model & Serial Number Label Figure 3 RB-2X Bantam Plus Portable test system rear panel nameplate containing equipment serial number Bantam Plus Getting Started Guide 21

22 2.2 Operational Considerations To protect the RB-2X Bantam Plus Portable Test System and ensure optimal performance, follow these guidelines: Placement: When placing the RB-2X Bantam Plus Portable Test System for use, avoid very wet or dusty environments.! CAUTION Electrical Shock hazard if equipment is exposed to water during operation. Cooling: When placing the RB-2X Bantam Plus Portable Test System for use, do not block the cooling vents on the front and back as shown in Figure 4. NOTE The RB-2X cooling fan is temperature controlled and will only operate when the internal temperature exceeds a preset threshold and before damage can occur due to excessive overheating. Periodically inspect and clean the air filter found at the front of unit. Power: The RB-2X Bantam Plus Portable Test System requires a source capable of providing at least 250 W of continuous power to operate correctly. Periodically inspect and clean removable filter Figure 4 Air flow inlet and filter Bantam Plus Getting Started Guide 22

23 2.2.1 Operational Considerations for testing Electro-mechanical meters Electro-mechanical meters will exhibit large errors if inserted into the Bantam Plus socket while in the normal test orientation. Use of the RB-MOUNT accessory will enable correct orientation for electro-mechanical meters. Furthermore, the RB- MOUNT can be used to attach the Bantam Plus to a wall or truck using the key holes found on the RB-MOUNT assembly. Wire form meter retainer Key holes for vertical mount RB-Mount Tee Bar Bubble level The RB-MOUNT is supplied with the following components; RB-Mount Assembly includes; Bubble Level Wire form Meter retainer clip User Guide Assembling the RB-MOUNT To assemble the RB-MOUNT to a Bantam Plus first release the retaining nuts securing the Tee Bar on the RB-MOUNT. a) Fully extend the Tee Bar and mount the assembly as shown in the following image. b) The Tee Bar should fit snuggly into the recess above the front fan filter and the rear of the mount should fit over the rear lip below the fan exhaust. c) Next loosen the two screws found at the rear of the Bantam Plus meter socket. Securely assemble the Wire form Meter retainer clip and retighten screws. d) The retainer clip is required to prevent some large electro mechanical meters from falling out of the Bantam Plus meter socket while in the vertical position. e) Finally, there are two feet that can be adjusted to level the mechanical meter in a vertical orientation for testing Bantam Plus Getting Started Guide 23

24 Assembled wire form meter retainer clip Adjustable feet Testing Electro-mechanical meters using the RB-MOUNT Testing Mechanical Meters using the RB-MOUNT. The following is guidance on how to test electro-mechanical meters using the RB- MOUNT. 1) Insert an Adjust Optics (AO) test step as step 1 of the test sequence. Set Revs for 5 revolutions. 2) Create a special electro-mechanical test sequence for full load, light load and Power Factor testing. 3) Insert the electro-mechanical meter into the test socket and position the sensor before orienting the Bantam Plus into the vertical position. 4) Start the test sequence while the Bantam Plus is running the first Optics Adjust test step orient the Bantam Plus into the vertical position and level. 5) Once the Optics Adjust test has detected the programmed number of Revs the Bantam Plus will automatically begin the first meter test. Use the Edit Test Sequence function to add an Optics Adjust to the Test Sequence Bantam Plus Getting Started Guide 24

25 2.3.0 RB-BPH Optional Carry Harness Attachment. The optional RB-BPH Carry Harness assembly is available to provide a comfortable carry position for long distance travel. The following RB-BPH instructions describe how to attach to the Bantam Plus; Step 1 Remove the three screws indicated below and retain in a safe place. Remove side mounts screws and retain in a safe place. Step 2 Align the holes of the RB-BPH with the holes in the case and use the three retaining screws and washers supplied with RB-BPH to fasten to the side of Bantam Plus as shown below. Step 3 Connect the adjustable stabilizing straps as shown below Bantam Plus Getting Started Guide 25

26 Step 4 Adjust any of the six strap lengths for a comfortable fit around torso and shoulders. The unit should fit securely to the back at or above the waist line. Care should be taken while maneuvering to ensure stability is maintained at all times RB-TSBR1 Optional Current Transformer Test Note: before RB-TSBR1 will operate the Bantam Plus may need updates to the internal firmware. To confirm Bantam Plus firmware revision select HELP from the main menu. Software version 8.5 or later is and RD Firmware version or later is required to enable the TSBR1 features. Call Radian Technical support for information on available software updates or see section describing how to access software remotely. The optional RB-TSBR1 Current Transformer Test module provides a solution to testing metering CTs on-site. The following guides you through the necessary steps required to operate the RB-TSBR Bantam Plus Getting Started Guide 26

27 Step 1 The Bantam Plus can be switched OFF or ON during the installation process. If switched ON ensure that the CT Application is not active by switching to the Main Menu. Step 2 - Install the RB-TSBR1 into the Bantam Plus socket and connect the AUX cable to the Bantam Plus AUX socket. Step 3 A choice of primary current clamps are available from Radian Research. For CT Ratio measurements connect a suitable current clamp to the RB-TSBR1 Clamp-on Transformer input. Step 4 Connect the Test Switch safety probe to the CT secondary via test switch. Step 5 Connect the Red (fused) connector to the Service Voltage. Connect the Green wire to a suitable ground. You are now ready to perform CT Ratio or Burden tests. Conducting A Current Transformer Test After connecting the RB-TSBR1 unit to the test switch, you're ready to set up the test. At the end of the test cycle, all the results will be saved at once. To begin: Step 1 Return to the Startup screen. Step 2 Click CT Testing on the Startup screen. A screen like this appears: Bantam Plus Getting Started Guide 27

28 You'll notice that Nameplate Ratio is already populated. This information is pulled from the Site Information you loaded earlier. If you have not used Site Information, you'd need to perform the following steps. Step 3 Enter the nameplate ratio of the current transformer being tested in Nameplate Ratio. Step 4 Place a check in the Ratio and Burden check boxes. Step 5 Place a check in Phases A or B or C by clicking the color coded box. This indicates that you'll be testing the specified phase of the current transformer. Step 6 Select 4.0 from Max Burden. Step 7 Click the Phase A tab. The following screen appears: Again, you'll notice that Serial No., Model No., and Class are already filled. If you didn't use site information, you would need to perform the following steps: Step 8 Enter the serial number of the current transformer being tested in Serial No. Step 9 Enter the model number of the current transformer being tested in Model No. Step 10 Enter the accuracy class of the current transformer being tested in Class. Step 11 Repeat steps 1 3 for each phase being tested. To select the current transformer information for a different phase, select the tab for that particular phase in the Current Transformer Information area. For example, if you are testing Phase A, B and C, then after performing steps 1 3 for the A phase Bantam Plus Getting Started Guide 28

29 tab you will repeat them under the Phase B tab and then again under the Phase C tab. But since you used a site information based workflow, you can go straight to testing the current transformer. Step 12 Click Start on the toolbar to begin the CT test. Viewing Current Transformer Test Results To view your saved current transformer test results, you'll need to close the current transformer testing screen and return to the Startup screen. From there: Step 1 Open the Administration screen by clicking Administration. Step 2 Click View/Edit Test Results. Step 3 Click CT Test Results. The Edit Current Transformer Test Results screen appears. It will look something like the following screen: Test results are arranged in order based on the date/time stamp and serial number of the current transformer entered during the current transformer test. Each burden step for each phase is saved as a separate record and includes all the information you entered in addition to the percent change, accuracy result, and test date. 3 Product Features Bantam Plus Getting Started Guide 29

30 This chapter provides detailed information on the product features of the RB-2X Bantam Plus Portable Test System and contains the following sections: 3.1 RB-2X Components and Controls 3.2 RB-2X Automated Software Controls 3.1 RB-2X Components and Controls Top Panel The components of the RB-2X Bantam Plus Portable Test System top panel are explained below. 1. Line Voltage ON/OFF 5 Ampere Breaker Switch: Used to power and protect the Bantam Plus.! CAUTION NOTE The input voltage operating range is 90V to 300V. The design will source 69V to 480V to the meter socket. Breaker switch is rated at 5 Amps. The Bantam Plus software operating system must be shut down before powering off the unit. 2. Front Panel Power indicator: Indicator light that glows blue when the RB-2X Bantam Plus power is on.! CAUTION Always check the service voltage before connecting the test cable. Connecting the equipment to an improper voltage will trip the breaker and can result in equipment damage. 3. Front Panel Voltage & Current Indicator: Red and Yellow LEDs will activate when Voltage and/or Current is applied to the integrated meter socket. 4. Pulse Detection Indicator: LED will flash green when a meter pulse is detected. A visible pulse sensor detection LED is duplicated within the integrated sensor Bantam Plus Getting Started Guide 30

31 head. 5. Volume Control: The Volume Control Keyboard is used to control the volume of the audible pulse the unit generates to echo pulses detected when conducting a meter test. The keys on the left and right lower and raise the volume respectively. Pressing the mute key will light the blue LED within the key indicating that the unit is muted. 6. Ports 1, 2 & 3: Ports 1 thru 3 are each suited to a particular type of optics. The connector. Port 1 is reserved for an Optocom (RB-Optocom) cable. Optocom Optics allows the operator to not only detect pulses from solid state meters, but also allows the operator to program the meter without changing the optical head. This connector may also be used for custom pickups as required. Contact Radian for any special needs that may not be met by the standard set of pickups. Port 2 is a REDEL connector reserved for a wide variety of optional optics accessories, including clamp-on, suction-cup and magnetic based reflect solid state optics. The red LED on the integrated Sensor Pro TM optics sensor provides a visual indication that the unit has detected a pulse. Port 3 is a BNC connector reserved for an optional click-switch adapter that is used when other optics aren't suitable. The BNC connector is also used when conducting a standards compare test. During normal testing when Input 3 is not the source this connector also outputs a test pulse for calibration purposes. NOTE An external sensor connected to Port 2 will not disable the Sensor Pro TM optics on board. 7. Advanced I/O: The Advanced I/O connector provides many capabilities for the testing of solid state meter. It can accommodate up to six Form A contact inputs or four Form C and two Form A contact inputs. For outputs, it has one programmable output allowing 0.01 to 40 seconds between contact transitions and a quantity of pulses (1 to 4094) to output. In addition two outputs can be software set high or low. There is also an unregulated 12VDC output. 8. Serial Interface: The RS232 serial interface connector is a multi-function input connector that can be used for a variety of accessories including a barcode Bantam Plus Getting Started Guide 31

32 scanner. 9. USB Interface: USB ports located one above the other. These can be used for connecting an optional keyboard, mouse or other USB device. 10. Ethernet Interface: A 10/100 Ethernet connection that can be used to connect the Bantam Plus to a local area network. This can be very useful for transferring test results from the Bantam Plus to a central database Bantam Plus Getting Started Guide 32

33 3.1.2 Touch Screen Display Applications that are gray will go active when hardware option is fitted. Alternative methods for selecting a meter test Administration Application Refer to Section 5 for more information. Site Information Application It is not necessary to use Site information to run a test. Refer to Section 8 Edit Profiles Application Refer to Section 5 for more information Utilities Application Refer to Section 6 for more information Figure 5 Bantam Plus Main Menu Screen The Bantam Plus touch screen allows you to make selections in the software without the need for a keyboard or mouse. Touch the display to make selections, or even type in data using the touch screen keyboards (see Figures 6,7,8). NOTE The display virtual buttons used to interact with the Bantam Plus software are set to single click. It is not necessary to "double click" to activate programs, activate buttons or otherwise interact with the unit. To perform a right click using a stylus, Click stylus to the touch screen and hold it in place for a few seconds Bantam Plus Getting Started Guide 33

34 Figure 6 Touch Screen Keyboard Figure 7 Numeric Screen Keyboard Figure 8 Windows Screen Keyboard Bantam Plus Getting Started Guide 34

35 4 Operations Overview This chapter provides general instructions for using the RB-2X Bantam Plus Portable Test System and contains the following sections: 4.1 Connecting the Bantam Plus 4.2 Conducting a Meter Test with the Bantam Plus 4.1 Initializing the Bantam Plus Powering on the unit To Power up the Bantam Plus using the Shop Power Cord: 1. Ensure the ON/OFF Breaker Switch on the rear panel is in the OFF position. 2. Connect the green ground wire coming from the Shop Power Cord through the ground terminal and tighten down the terminal. Make sure the ground cable is secure before continuing. 3. Plug the two black banana plugs coming from the Power Cord into the banana sockets on the rear panel of the Bantam Plus. NOTE Live and Neutral orientation is not important as supplies are fully isolated and fused on both neutral and line. 4. Insert the plug end of the Shop Power Cord into a 90V-300V grounded outlet. When switched ON the software will automatically launch. Since the internal PC will have to boot up, it may take a few seconds for the unit to launch the control application Powering on the unit in the field In the field you can use the Field Power Cord and Field Safety Ground Cable to draw power directly from the meter test switch. To do so: 1. Open all the test switches. 2. Make sure the potential is between 90 and 300 volts 3. Connect the green Field Safety Ground Cable through the ground terminal and tighten down the terminal. Make sure the ground cable is secure before continuing Bantam Plus Getting Started Guide 35

36 4. Plug the black cable coming from the Field Power Cord into the black connector on the rear panel of the Bantam Plus. 5. Clamp the Field Safety Ground Cable to the meter block ground lug. 6. Clamp one lead from the Field Power Cord onto the neutral lower side test switch. Clamp the other lead from the Field Power Cord onto the phase A lower side test switch. 7. When the last connection is made and the switch/breaker is turned on the unit will power up and the Bantam Plus software will automatically launch.! CAUTION Always disconnect the ground connector last. Failure to do so can result in equipment damage or personal injury Bantam Plus Getting Started Guide 36

37 4.2.1 Conducting a Meter Test with the Bantam Plus Integrated Socket NOTE The test procedure described below assumes the meter is removed from the meter socket and inserted into the Bantam Plus integrate socket and the internal Sensor Pro optic sensor is used. For detailed explanation on using Bantam Plus to test meters in the meter panel using the optional RB- MTA see section Follow these steps to conduct a Form 2S Meter test with the RB-2X Bantam Plus Portable Test System: 1. Power the Bantam Plus using the instructions described in section or You will hear an audible tone three times from internal RD Reference Standard during power-up this indicate the internal reference standard is operational. 2. See Figure 9 for a Bantam Plus screen tour. Profile TAB accesses addition profile pages. A maximum of 30 profiles can be assigned by the operator. 3. For the purpose of this exercise we will assume no Profiles have been created. Select METER TEST Select Main Menu Tab to view additional Administration and Utilities Application Icons Profile keys are short cuts to pre-assigned meter information. Meter information can be assigned to each Profile from the Edit Profile key and stored in non volatile RAM. Select Meter Test to bypass a Profile and run a meter test Before powering down the Bantam Plus Select Shutdown to exit Figure 9 Bantam Plus Screen Tour Bantam Plus Getting Started Guide 37

38 4. Bantam Plus will implement an initialization sequence. Before proceeding with a meter test verify the Kh is correct for the meter under test. The optics should now be aligned. Select a Meter Test Test Sequence; Multiple test can be created. E.g. Demand Test, Quick Test, Default, etc. Use Form Drop down menu to select 2S Meter Adjust Optics Review Status line information before and during a meter test ensures Bantam Plus is ready and operating correctly. Figure 10 Bantam Plus Meter Testing Screen NOTE The integrated Sensor Pro is designed to accommodate meters with very low level pulse emission or during operation in bright sunlight. For optimal sensitivity position sensor head 1 inch between the Meter glass and the sensor. Use the target on the Sensor Pro to assist in alignment. 6. The integrated Sensor Pro is assigned to Optics 2 (Port 2). Select Adjust Optics button from the screen soft menu. Physically align the Sensor over the Meter Pulse output. During alignment view the flashing Red LED in the rear of the Sensor Pro head for visible activity Bantam Plus Getting Started Guide 38

39 NOTE A secondary Pulse LED can also be viewed on the display bezel. Pulses are also registered using an audible beep. Un-mute and increase the volume using the Bantam Plus keypad found below the display. For high Kh the sensor pulse duty cycle may be long. 7. Once the sensor is aligned the meter is ready to begin testing. 8. Verify the Meter form and Kh value is correct. Review the test sequence for appropriate steps before selecting the Start soft key. 9. Select start and validate the Voltage and Current LEDs on the front display bezel are active. Test Pointer indicates actual test being performed As found, As Left measurement results. Green indicates Pass, Red fail declared specification Indicate source Voltage, Current and Phase applied to meter Revolutions or Pulses remaining in current test Step. Status bar will indicates test status Figure 11 Bantam Plus Run Test Screen Bantam Plus Getting Started Guide 39

40 NOTE If a run is repeated the data from a second test will populate the AS LEFT field. 10. To cancel a meter test at any time select CANCEL from the display softkey. 11. Results may be viewed from the Administration Application see section Bantam Plus Getting Started Guide 40

41 4.2.2 Meter Test using Meter Test Adapter RB-MTA, RB-MTA-BN or RB- MTA-DB option. NOTE The optional MTA Adapter is designed for testing Transformer rated meters while housed within a meter socket or test panel. Figure 12 Meter Test Adapter RB-MTA Before using the RB-MTA Adapter set the Meter base to T (T Base) in the Test Sequence screen as seen in Figure 13 below. T Base is unique to using the RB-MTA Adapter. The correct Voltage routing for the T base can be configured for any specific meter form by selecting the Administration Icon followed by Edit Meter Setup and Socket Power Setup icon as shown in Figure 14. Figure 13 Setting the Form to Match MTA Adapter Requirements To test a Transformer rated meter use the following steps; Bantam Plus Getting Started Guide 41

42 1. Connect the Bantam Plus Ground connection to a suitable ground at the Meter housing assembly or test panel. 2. Connect the RB-Field Power cable to the service voltage, ensure not to exceed 300V. 3. Before powering on the Bantam Plus ensure that the Meter Test Adapter is inserted into the Bantam Plus meter socket. Orientation of the MTA to the socket is important. The MTA adapter cables facing to the rear of Bantam Plus. 4. Connect the RB-MTA to the meter test switch. Care should be taken to ensure the elements are correctly matched for the meter under test and the meter test switch used. For more details on the different meter forms and their pin outs refer to the MTA Connection Guide. 5. Connect a suitable external pulse sensor to either Port 1, 2 or Power ON the Bantam Plus and wait for initialization. 7. Select the appropriate Meter Form and test sequence. 8. Begin Adjust Optics Test from within the Meter Test Application to align the external pulse sensor to the meter. 9. Select Start to begin meter test. 10. On completion of meter test power down the Bantam Plus and remove the cables from the meter test switch. 11. Finally remove the ground cable from the meter test box. NOTE The RB-MTA option is specified to operate to a maximum of 20 Amps. No damage will occur if >20 Amps is delivered. However, the cable length will have appreciable burden and may not deliver the full rated current. Figure 14 Socket Voltage routing for the RB-MTA Adapter Form Bantam Plus Getting Started Guide 42

43 4.2.3 Creating a Transducer Test Sequence 1. From the main menu click Transducer Testing. 2. Click Edit Xdcr Seq. NOTE A default sequence is available; if additional sequences are required follow the instructions below. Appropriate upper and lower limits must be set based on the transducer tolerance. 1. Click Add on the right side of the screen. 2. Click Add New Sequence. 3. Type in a name for the transducer test sequence. In this example use the name Test Bantam Plus Getting Started Guide 43

44 Each sequence will have voltage, current, and phase angle in the sequence. Every Sequence must have voltage for reference purposes. Add current and phase angle only as needed. Enter the values for your test sequence. 1. In Test Volts enter In Test Amps enter In Phase Angle enter In Test Duration enter 15 to indicate that the test should run for 15 seconds. 5. Click Add. A new line, Step 2, will appear identical to the line above it. Change any variables that you need. For this example change Test Amps to Click Add. A new line, Step 3, will appear identical to Step 2. Change Test Amps to Click Save. You can create as many different test sequences as you want. Each sequence can have as many steps as you need Bantam Plus Getting Started Guide 44

45 4.2.4 Conducting a Transducer Test NOTE The optional RB-MTA Adapter is required for testing Transducers To test a Transducer use the following steps; 1. From the main menu click Transducer Testing. 2. Click Run Xdcr Test. There will be three tabs at the top of the page: Setup, Testing, and SCADA. Fill out the information on the Setup tab from the faceplate of the transducer. This information can be preloaded using Site Information. As an example set up a single element Watt test with a transducer with the following faceplate information Output: 0 to 1.2 ma, Max input: 120V, 5A, and Scale: 0 to 600W. 3. From the Type box select Watts - 1 elm. 4. In Output enter 0 and In Metric Scale enter 0 and Leave the CT and PT Ratios set to 1 and In Serial # enter In Company # enter RADIAN. 9. In Manufacturer enter (xxxxxxxx). 10. In Model enter 2206C Bantam Plus Getting Started Guide 45

46 RADIAN 11. Go to the Testing tab shown below. 12. Click on the Test Sequence box and select the test sequence you wish to run. In this case, select the test sequence created earlier. 13. To customize the test sequence, use the scroll bar at the bottom of the screen, scroll to the right and make any necessary changes. All of these fields can be edited on this screen or in the test sequence editor. See "Creating a Transducer Test Sequence" on Page Click Options to open the Transducer Test Options window Bantam Plus Getting Started Guide 46

47 15. Choose a test mode. Selecting Normal Mode runs the test through the entire test sequence before stopping. Selecting Pause Mode will stop the test after each step with voltage and current still applied. It will not continue to the next step until you click Start. If you need to document the SCADA readings we suggest you select Pause Mode. 16. Select delay rates. There may be some delay time necessary for the transducer to begin outputting valid data before each test step. Start Delay is the amount of time before the first test step begins. Settle Delay is the amount of time between subsequent test steps. Note that 1000ms = 1sec. In this example we have set the Start Delay to 0, and the Settle Delay to Select how you want the transducer test results displayed by selecting one of the options in the Results Display area. In this example we've selected % Error of Reading. 18. Click OK to confirm your options. 19. Now connect the cables to the transducer. 20. Using the Bantam Plus with RB-MTA adapter voltage and current leads, connect voltage and/or current to the transducer as needed. 21. Connect the analog sense cable to the transducer output. Black to +. White to -. Connect the other end of the analog sense cable to Pulse Input 1 on the Bantam Plus Bantam Plus Getting Started Guide 47

48 22. At the top of the screen click Start to run test. The transducer test will run. Notice that a. Accuracies inside the defined limits show up highlighted in green, and b. Accuracies outside the defined limits show up highlighted in red. 23. Click Save at the top of the screen to save the test data. The data will be saved by site name and by serial number Bantam Plus Getting Started Guide 48

49 NOTE If you need to document any SCADA (Supervisory Control and Data Acquisition) follow the steps below If you need to document any SCADA (Supervisory Control and Data Acquisition) readings, use the pause mode. This will pause the test after each test step. Voltage and current will still be applied when paused. Then click the SCADA tab. The instantaneous results continuously update every 0.5 seconds. These readings can be compared to the SCADA readings and documented. If a value is entered into the SCADA readings area, it will be saved when Start is clicked, and the test moves on to the next step. These values are optional, and you do not have to enter a value into this field. If no value is entered, nothing will be saved in the SCADA fields for that test step. Another use for the SCADA tab can be to adjust your transducer. You can select a test step, click Adjust Optics, and then go to the SCADA tab to see the instantaneous input and output values. Then the transducer can be adjusted (with a trim pot) to desired values. You can also return to the Testing tab, select another step, and click Adjust Optics again, and it will automatically adjust the values for that row. You do not need to cancel the test each time you want to update the values Bantam Plus Getting Started Guide 49

50 5 RB-2X Administration Application This chapter describes the Administration Application structure of the RB-2X and contains the following section: 5.1 Administration Overview 5.1 Administration Application Overview Figure below shows the Administration application screen. An overview of each function is summarized. Figure 15 RB-2X Administration View Edit Form Defaults: Bantam Plus is supplied with all ANSI forms already defined. Edit Forms allows you to customize settings for Bantam Plus Getting Started Guide 50

51 specific meter forms Edit Test Sequences: to view, add, edit, delete, import or export test Sequences View/Edit Test Results: allows the operator to access test results that have previously been saved to the Bantam Plus Edit Customer List: allow you to build a customer list to keep track of test results for multiple meters with different ownership. Only test results saved for the current customer will appear in the View/Edit Test Results screen Edit DataView & Import Export Options: allow you to customize the data view screen and establish how to define custom field names for imported or exported data. Data import/export is performed using the supplied WATT-Net software Edit Drop Down Code: is used to customize the valid values associated with a field defined in the Edit DataView and Import/Export Setting screen. An example of codes defined in the Edit Drop Down Codes screen would be a list of valid manufactures that can be selected at the test time from a drop down list Edit Barcode: screen provides access to the editors necessary to set up the Bantam Plus barcode reading functionality. From the Edit Barcode screen you can edit the barcode table, define custom barcode labels, and edit manufacturer codes Edit Meter Setup: screen allows you to customize many important power generation functions Options: screen allows you to change the displayed color scheme and Network Options including TCP/IP address Bantam Plus Getting Started Guide 51

52 6 RB-2X Utilities Application This chapter describes the Utilities Application structure of the RB-2X and contains the following section: 6.1 Utilities Overview 6.1 Utilities Overview Figure 16 below shows the Administration Application screen. An overview of each function is explained. Figure 16 RB-2X Utilities Application view Bantam Plus Getting Started Guide 52

53 6.1.1 Standards Compare: allows the operator to perform an automated comparison of the Bantam Plus internal reference with an external reference standard. Option RB-SCA will be required for this function. For more detail on how to perform a Standards Compare view the video posted at and section Run Sinewave Editor: Bantam Plus generates sine waves with low THD. To simulate real world phenomena the source is capable of generating voltage and current waveforms with harmonic content. Load and save waveforms. Once a waveform is created it must be saved so that it can be selected for use by the Meter Test Screen option forms External RD Comm: enables an external PC to communicate directly with the internal Reference Standard Remote Control Desktop Settings: enables a remote desktop to control the Bantam Plus via Ethernet Remote Assistant: enables operator to request remote assistance Updates Back-up and Restore: enables the operator to check for software & firmware update, restore Windows settings, back-up files Bantam Plus Getting Started Guide 53

54 7 RB-2X Site Information Application This chapter describes the Site Information Application structure of the RB-2X and contains the following sections. 7.1 Site Information Application Overview 7.1 Site Information Application Overview Figure 17 below shows the Site Information screen. It is not necessary to set up information for a site, but doing so can greatly streamline your meter testing workflow. Site information is a collection of data specific to a location where a meter or meters, current transformer, potential transformer, or combination of these is regularly tested. You enter the information associated with a site once and then load the site before a test so that the information is automatically populated in the necessary fields throughout the various testing screens. Confirmation of Site Information, including ability to add meter's serial number, can be viewed by selecting the Data View key found in the Meter Test Window, reducing or negating the need for input from the operator. Figure 17 Site Information Application View Bantam Plus Getting Started Guide 54

55 7.1.1 Edit Site Information: allows the operator to add or edit site information Load Site Information: allows the operator review, edit previously saved site information Site Report: allows the operator to select, review and print a site report. Access to Data View screen Toggle key to change appearance of Data View screen. Figure 18 View of the Meter Test screen with the Data View enabled to view or edit Meter information Bantam Plus Getting Started Guide 55

56 8 Routine Maintenance and Service This chapter contains the following sections: 8.1 Contact Information 8.2 Routine Maintenance 8.3 Service 8.4 Helpful Documentation and Resources 8.1 Contact Information For questions related to maintenance and service, contact : 3852 Fortune Drive Lafayette, IN USA Tel: (765) Fax: (765) radian@radianresearch.com Website: Routine Maintenance The RB-2X Bantam Plus Portable Test System is requires the following routine maintenance: Frequency Activity Before each use Inspect the test cable for damage. Check the air filter is clean. Before storing the equipment Wipe exterior surfaces with a dry, soft cloth to remove dust and dirt. Do not use solvents to clean plastic surfaces. Yearly Calibrate the Bantam Plus Bantam Plus Getting Started Guide 56

57 8.3 Service Service The Bantam Plus equipment is designed for testing meters and used as part of your organization's quality control system. The procedure below outlines the limited parts that are customer replaceable. Over extended use, the current carrying socket jaws may foul with contaminates such as oil or grease and no longer produce the contact necessary to operate to specification. The following procedure describes how to periodically clean or replace these jaws. Remove the five Torx screws to expose the socket assembly Step 1. Ensure the Bantam Plus is switched off and isolated from line voltage. Step 2. Remove the five Torx drive screws from the socket cover. Step 3. Remove the socket cover to expose the socket assembly. Step 4. Note that each current conductor has a replaceable liner. Clean each liner using compressed air being careful that all loose debris is removed. Should oil or grease be present, remove the liner from the Bantam Plus before using oil based solvent for cleaning Bantam Plus Getting Started Guide 57

58 Step 5. If necessary liners can be replaced using of RB-SMK Socket Maintenance Kit available from Radian Research. Step 6. Before replacing the socket assembly cover, ensure that the socket assembly dividers found on the base of the socket assembly cover sit either side the voltage conductors. Failure to do so could result in bending the voltage conductors preventing a meter insertion. Replace the socket assembly cover and retighten the five Torx screws. Step 7. Perform a Standards Compare to validate the performance using Standards Compare information found in section 6.1 and Removable socket liners Figure 19 Removable Socket Liners! WARNING The RB-2X Bantam Plus Portable Test System produces high voltages and is serviceable only by qualified personnel. Attempts to service the equipment by unqualified personnel can result in personnel injury Warranty Service warrants that each product is free from defects in material and workmanship. Our obligation under this warranty is to repair or replace any instrument or component therein that, within two years after shipment and with normal use, proves to be defective upon examination Bantam Plus Getting Started Guide 58

59 To Obtain Warranty Service All warranty returns must have a return materials authorization (RMA) number. To obtain an RMA, visit Follow these guidelines to ensure prompt warranty service: must authorize all warranty replacements. Ship returned items prepaid, fully insured, and in the original packing to minimize the possibility of damage. will not accept collect shipments and does not accept liability for damage caused by improper packing or handling during shipment. Include in the shipment a detailed description of the problem and the events that led up to the development of the problem. will pay local domestic surface freight costs to return the product to the customer. Radian will not pay for overnight or express shipping service. Use the following address for warranty returns: 3852 Fortune Drive Lafayette, IN USA Attn: RB-2X Service After-Warranty Service If after-warranty service by is needed: A purchase order is required. The owner must pay all shipping costs. If requested, can provide an estimate for the repair; however, if the repair is not made, the cost of labor required to obtain the estimate will be invoiced at the hourly repair rate. To Obtain After-Warranty Service All after-warranty service requests must have a return materials authorization (RMA) number. To obtain an RMA, visit Payment information must also be provided (purchase order or credit card). Please follow these guidelines to ensure prompt after-warranty service: Ship returned items prepaid, fully insured, and in the original packing to Bantam Plus Getting Started Guide 59

60 minimize the possibility of damage. Include in the shipment a detailed description of the problem and the events that led up to the development of the problem. will invoice return shipping costs to the customer Standards Compare and use of the RB-SCA Option Standards Compare is a function that enables the internal Bantam Plus Reference Standard to be compared periodically with an external Reference Standard. The process is defined as a Standards Compare. The Bantam Plus is supplied with an automated test sequence for testing the internal reference against an external reference. It is recommended that the accuracy of external reference standard is at least four times better than the accuracy of the Bantam Plus. For guidance use an RD-23 (0.01%) to perform Standards Compare. However, a recently calibrated RD- 20 or RD-21 may also be suitable. Connecting the RB-SCA to the Bantam Plus. Insert the RB-SCA into the Bantam Plus meter test socket as shown in the picture below. Ensure the RB-SCA cables are oriented to the rear of the Bantam Plus. Each current cable is color coded in pairs and terminated with a Red or Black 6mm locking banana plug. Connect each pair to the external Reference standard paying attention to the phase orientation. Connect the current cables marked with the Red Bantam Plus Getting Started Guide 60

61 band to the RD Phase A Input, connect the Yellow band cables to the B phase and the Blue band cables to the C phase inputs on the RD. The red and black 4mm banana plugs to the RD-2X Potential inputs. Connect a BNC cable between the Bantam Plus Optics Port 3 and the RD-2X Port 2. Finally connect Line Voltage to the RD-2X AUX Input to power the RD standard. Standards Compare To configure the Bantam Plus for Standards Compare go to the Main Menu and select the Utilities Icon. Within the Utilities screen select the Standards Compare icon and select Run Standards Compare The Bantam Plus is supplied with a default Standards Compare test sequence. Note: the default test sequence is developed for a RB-20 (0.04%) Bantam Plus. Before running a Standards Compare with RB-21 (0.02%) Bantam Plus the test sequence must first be edited to change the test tolerance upper and lower limits to %/- 0.02%. To do this select Utilities and select Edit Standards Compare Running a Standards Compare Enter the external RD serial number into the Ext. Standard SN field. Select Ext. Standard: to 1 Phase. Select Start to begin the standards compare. When the test sequence is complete select Save to save the test results. To view the test results select View Standards Compare Results icon and load the appropriate results that are date and time stamped for convenience Bantam Plus Getting Started Guide 61

62 8.3.5 Updating Bantam Plus Firmware It is recommend that the Bantam Plus firmware is the latest version before calling the Radian technical support group. Confirming and updating the Bantam Plus firmware can be achieved by connecting the Bantam Plus to your network and access the internet. Note: Some company firewalls may prevent access to the internet. Once connected to the network select Utilities, Update Backup & Restore To confirm and update the Bantam Plus firmware version relative to the latest available select Check For Updates Then follow the onscreen prompts to update the software. NOTE Do not interrupt the update process while it is downloading and updating the software Bantam Plus Getting Started Guide 62

63 Once updates are complete rerun Check For Updates to confirm the software versions match the latest available Bantam Plus Getting Started Guide 63

64 8.4 Helpful Documentation and Resources Visit the Radian web site at: Bantam Plus Getting Started Guide 64

Research, Inc. About This Getting Started Guide

Research, Inc. About This Getting Started Guide Research, Inc About This Getting Started Guide makes no warranty on the accuracy of the information contained in this getting started guide and accepts no liability for its use. The information contained

More information

Research, Inc. About This Getting Started Guide

Research, Inc. About This Getting Started Guide Research, Inc About This Getting Started Guide makes no warranty on the accuracy of the information contained in this getting started guide and accepts no liability for its use. The information contained

More information

0Radian Research, Inc

0Radian Research, Inc 0Radian Research, Inc About This Manual makes no warranty on the accuracy of the information contained in this manual and accepts no liability for its use. The information contained in this manual remains

More information

WE-30. Portable Three-Phase Meter Tester/Analyzer

WE-30. Portable Three-Phase Meter Tester/Analyzer Portable Three-Phase Meter Tester/Analyzer WE-30 333 Crosspark Drive Pearl, Mississippi 39208 USA P: 601.933.0900 F: 601.933.0901 E: sales@watthour.com www.watthour.com Portable Three-Phase Meter Tester/Analyzer

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Portable Airborne Particle Counter (particle counter). This guide will

More information

Portable Three-Phase Meter Site Analyzer

Portable Three-Phase Meter Site Analyzer Three-Phase Customer Load Field Testing Portable Three-Phase Meter Site Analyzer Radian Research Reference Standard Accuracy Proven Portable Three-Phase Meter Site Analyzer RW-30X NS RW-31X NS tests,

More information

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

WE-20. Quick Start Guide For Operating The. Portable Three-Phase Meter Tester/Analyzer

WE-20. Quick Start Guide For Operating The. Portable Three-Phase Meter Tester/Analyzer Quick Start Guide For Operating The WE-20 Portable Three-Phase Meter Tester/Analyzer 333 Crosspark Drive Pearl, Mississippi 39208 USA P: 601.933.0900 F: 601.933.0901 E: sales@watthour.com www.watthour.com

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

E2460GS Oscilloscope Upgrade Kit

E2460GS Oscilloscope Upgrade Kit Installation Instructions for E2460GS Oscilloscope Upgrade Kit Agilent 1670G-Series Logic Analyzers This kit upgrades either the Agilent Technologies 1670G, Agilent 1671G, Agilent 1672G, or the Agilent

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

M A C 3 Wind Speed Alarm & Controller

M A C 3 Wind Speed Alarm & Controller M A C 3 Wind Speed Alarm & Controller Installation Instructions Thank you for purchasing the MAC3 wind speed alarm and controller. This manual is designed to lead you through a step-by-step process to

More information

EnerSure Installation Guide

EnerSure Installation Guide EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded

More information

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... 2 1.0 General Information... 3 1.1 System Components... 3 1.2 Specifications... 3 1.2.1 Torque Ranges... 3 1.2.2 Electrical Specifications...

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 ) Installation Manual 65 (64.56 ) Model: HILF65101 65 Interactive LED/LCD QUICK SETUP GUIDE For further information, see the user manual. Please contact directly if you have questions on the use of the touch

More information

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits. This Datasheet for the IC660BBD110 Block 115Vac Input 16 Circuits http://www.cimtecautomation.com/parts/p-14435-ic660bbd110.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

OPERATING INSTRUCTIONS. For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM. Serial Number: Leaflet Number G.

OPERATING INSTRUCTIONS. For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM. Serial Number: Leaflet Number G. OPERATING INSTRUCTIONS For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM Serial Number: Leaflet Number 2 015 G October 2016 Knopp Incorporated 1307 66th Street Emeryville, California 94608

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

VBT-75 S2 VACUUM BOTTLE TESTER

VBT-75 S2 VACUUM BOTTLE TESTER VBT-75 S2 VACUUM BOTTLE TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 July 7, 2017 Revision 1 SAFETY

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Hardware Reference Guide For Thin Clients

Hardware Reference Guide For Thin Clients b Hardware Reference Guide For Thin Clients Document Part Number: 254241-001 July 2002 This book provides basic hardware information for this series of Compaq Thin Clients. Å WARNING: Ä CAUTION: 2002 Compaq

More information

User Operation Manual: Motorized Valve Controller for Valved Sources

User Operation Manual: Motorized Valve Controller for Valved Sources User Operation Manual: Motorized Valve Controller for Valved Sources Table of Contents BEFORE YOU BEGIN...2 Safety Precautions...2 Product Concerns...2 Specifications...3 Support...3 INTRODUCTION...4 Product

More information

Agilent Technologies 16700B-Series Logic Analysis Systems. Installation Guide. Publication number November 2002

Agilent Technologies 16700B-Series Logic Analysis Systems. Installation Guide. Publication number November 2002 Installation Guide Publication number 16700-97023 November 2002 For Safety information and Regulatory information, see the pages behind the index. Copyright Agilent Technologies 2000-2002 All Rights Reserved

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation.

More information

Site Readiness Guide. September 2015

Site Readiness Guide. September 2015 Site Readiness Guide September 2015 Copyright This document is provided "as-is." Information and views expressed in this document, including URL and other Internet website references, may change without

More information

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition). PowerCore Model MPC-20 Installation Manual *Approved by CSA for non-hazardous locations (Group Safety Publication IEC 61010-1 Third Edition). Products covered in this document comply with European Council

More information

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II Reclosers Form 4C Microprocessor-Based Recloser Control KME4-88-1 (120V) and KME4-88-2 (240V) Analog Current Metering Accessory Design II Service Information S280-77-6 961015, 961016 Figure 1. Kyle KME4-88

More information

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Model 9306 Handheld Airborne Particle Counter. This guide will help you quickly begin using

More information

MAC3 Wind Speed Alarm & Controller. Installation Instructions

MAC3 Wind Speed Alarm & Controller. Installation Instructions MAC3 Wind Speed Alarm & Controller Installation Instructions Table of Contents Overview... 3 Installation... 3 Optional Equipment... 10 Dual Sensor Operation... 10 Other Optional Equipment... 10 Operation

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Zonit μats TM Users Guide μats1-lv Version 1.2

Zonit μats TM Users Guide μats1-lv Version 1.2 Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation

More information

Operations Manual. Model 622 UTEC Calibrator. Radian Research, Inc.

Operations Manual. Model 622 UTEC Calibrator. Radian Research, Inc. Radian Research, Inc. Model 622 UTEC Calibrator Operations Manual Radian Research, Inc. 3852 Fortune Drive Lafayette, IN 47905 USA Tel: 765-449-5500 Fax: 765-448-4614 www.radianresearch.com NOTICE...3

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

What s in the Box? REAR VIEW SAFETY

What s in the Box? REAR VIEW SAFETY TM 1 What s in the Box? 1 Full HD Color Infra-red Weather Proof Camera 1 Full HD 7" TFT LCD Color Monitor w/monitor Mount 1 Power Harness 1 66 Camera Cable 1 Power Connection Wire 1 Screw Kit for installation

More information

Dell Inspiron N5110 Service Manual

Dell Inspiron N5110 Service Manual Dell Inspiron N5110 Service Manual Regulatory model: P17F Regulatory type: P17F001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Universal AC Power Source + AC Power Analyzer

Universal AC Power Source + AC Power Analyzer User's Guide Universal AC Power Source + AC Power Analyzer Model 380820 Introduction Congratulations on your purchase of the Extech Model 380820. This Universal AC Power Source and AC Power Analyzer can

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd PRODUCT MANUAL Power Supply Westell Technologies. 960-1152-MNL rd DISCLAIMER All information and statements contained herein are accurate to the best of Westell Technologies knowledge. Westell Technologies

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-STC Kelvin Standard Triaxial Connector Card Description The Model 8020-STC Kelvin Standard

More information

KBMG MULTI-SPEED BOARD

KBMG MULTI-SPEED BOARD TM INSTALLATION AND OPERATION MANUAL KBMG MULTI-SPEED BOARD KB Part No. 8833 Multi-Speed Board for KBMG Series Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this

More information

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL ANI-15115-08SWH PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: sales@a-neutronics.com

More information

ACT-1B Series Panel Tachometer

ACT-1B Series Panel Tachometer MONARCH INSTRUMENT Instruction Manual ACT-1B Series Panel Tachometer Printed in the U.S.A. Copyright 2009 Monarch Instrument, all rights reserved 1071-4843-111R 0909 15 Columbia Drive Amherst, NH 03031

More information

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers Table of Contents Package Contents.............. 1 Warranty.............. 1 Installation.............. 2 Maintenance

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

XPD-28 2:8 DMX & RDM Splitter User Manual

XPD-28 2:8 DMX & RDM Splitter User Manual XPD-28 2:8 DMX & RDM Splitter User Manual 2 UM_XPD-28-D0-LEN-V01-00.DOCX 2015-10-26 Index Index... 3 Introduction... 4 Unpacking... 5 Safety Information... 5 Device Overview... 7 Settings and Menu... 9

More information

user manual AMOS-2000 Universal Compact, Chassis System, Supporting Nano-ITX Embedded Boards Revision

user manual AMOS-2000 Universal Compact, Chassis System, Supporting Nano-ITX Embedded Boards Revision Revision 0.20 020-10122009-1415 user manual AMOS-2000 Universal Compact, Chassis System, Supporting Nano-ITX Embedded Boards Copyright and Trademarks Copyright 2009 VIA Technologies Incorporated. All rights

More information

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS Pro 900 software Us er Documentation Installation and Operation Back-UPS Pro 900 Inventory Connect the Battery bu001a User Documentation (2) Safety and General Information Inspect the package contents upon receipt.

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444 Product Manual 01504 (Revision B) Original Instructions RVDT Setup and Polarity Checking Tool for EG Governors T87444 Operation and Calibration Manual General Precautions Read this entire manual and all

More information

Installation and Operation Manual Back-UPS BR900G-RS

Installation and Operation Manual Back-UPS BR900G-RS Installation and Operation Manual Back-UPS BR900G-RS Inventory Safety bu001a This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there

More information

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-KHV Kelvin Keithley Triaxial Connector Card Description The Model 8020-KHV Keithley HV Connector

More information

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer INSTRUCTION MANUAL Instruction Manual Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance

More information

actilib Library 2U Quick Start Guide

actilib Library 2U Quick Start Guide actilib Library 2U Quick Start Guide September, 2009 1 Contents 1 Contents...2 2 Warnings and symbols...3 2.1 Precautions...4 2.2 Product Warranty Caution...4 2.3 Rack stability...4 3 Unpacking the tape

More information

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs This Datasheet for the IC660BBA104 Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs http://www.qualitrol.com/shop/p-14425-ic660bba104.aspx Provides the wiring diagrams and installation guidelines

More information

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME Reclosers Form 4C Microprocessor-Based Recloser Control Analog Current Metering Accessory KME4-82-1, KME4-82-2 Installation and Operation Instructions Service Information S280-77-8 Figure 1. Kyle Form

More information

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

Site Readiness Guide. October 2017

Site Readiness Guide. October 2017 Site Readiness Guide October 2017 Copyright This document is provided "as-is." Information and views expressed in this document, including URL and other Internet website references, may change without

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30

More information

Customer Replacement Procedure

Customer Replacement Procedure Customer Replacement Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 80-drive DAE cooling module 302-003-777 REV 01 July 2017 This document describes how to replace

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs) Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2

More information

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS Pro 900 Us er Documentation Installation and Operation Back-UPS Pro 900 Inventory bu001a User Documentation (2) Safety and General Information Inspect the package contents upon receipt. Notify the carrier and

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

Economy Single Channel Output DC Power Supply

Economy Single Channel Output DC Power Supply Economy Single Channel Output DC Power Supply User Manual www.owon.com.cn Feb. 2019 edition V1.1.0 Copyright LILLIPUT Company. All rights reserved. The LILLIPUT's products are under the protection of the

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Dell XPS 14z Owner s Manual

Dell XPS 14z Owner s Manual Dell XPS 14z Owner s Manual Computer model: L412z Regulatory model: P24G series Regulatory type: P24G001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

TH2683 Insulation Resistance Meter. User s Mannual

TH2683 Insulation Resistance Meter. User s Mannual TH2683 Insulation Resistance Meter User s Mannual 1 CONTENTS Chapter 1 Genernal Information... 3 1.1 Feature Overview... 3 1.2 Operating Environment... 3 1.3 Dimensions and Weight... 3 1.4 Unpacking Inspection...

More information

Service Instructions. Conductor 420

Service Instructions. Conductor 420 Service Instructions Conductor 420 Listed, File No. E195547 Input: 480 VAC, 50/60 HZ. (Operating range 380-480 VAC) 20 AMP MAX OUTPUT W/25 AMP FUSE Output: 0-90% of Input Voltage Table of Contents General

More information

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online! User s Guide Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server Quick Start Guide Video Available Online! Visit http://www.sonnettech.com/product/ mobilerackkit.html Click the Video

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY JANOME DESKTOP ROBOT JR2000N Series Operation Manual For Qualified Installer ONLY Thank you for purchasing the Janome Robot. *Read this manual thoroughly in order to properly use this robot. Be sure

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL PHASETRONICS Specialists EP1 Series Power Control Single Phase SCR 10-50 Amps OPERATION & SERVICE MANUAL Phasetronics, Inc. P.O. Box 5988 1600 Sunshine Drive Clearwater, FL 33765 (727)573-1900 FAX(727)573-1803

More information

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display Installation Manual Model: HILU750 '' Ultra HD Interactive Flat Panel Display QUICK SETUP GUIDE For further information, see the User Manual. Please contact HITACHI directly if you have questions on the

More information

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

The Nureva Span ideation system. Installation guide. Single panoramic system

The Nureva Span ideation system. Installation guide. Single panoramic system The Nureva Span ideation system Installation guide Single panoramic system Important SAFETY WARNINGS Prior to the installation of this product, the installation instructions should be completely read and

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1000 Part No. 23624 OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1000 OV1000 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information