Research, Inc. About This Getting Started Guide

Size: px
Start display at page:

Download "Research, Inc. About This Getting Started Guide"

Transcription

1

2 Research, Inc About This Getting Started Guide makes no warranty on the accuracy of the information contained in this getting started guide and accepts no liability for its use. The information contained in this getting started guide remains the property of It is provided in good faith for the operation and servicing of this product. We reserve the right to take legal action where this information is divulged to third parties without our written consent or in circumstances that may cause us commercial harm. The operation of this equipment requires training and experience in electric meter testing. The information in this getting started guide is designed to supplement existing knowledge and experience already attained and practiced by journeyman-level meter test technicians. Novice meter test technicians should not attempt to operate this equipment without first gaining the basic knowledge of meter testing and the application of meter testing equipment from a certified training course. Copyright 2012 Radian Research reserves the right to change any information in this document without notice.

3 Table of Contents About This Getting Started Guide Product Introduction and Specifications Product Overview Optional Accessories Product Features RB-20 Portable Test System RB-2X Embedded Winboard Software Safety Information General Safety Summary Symbols Found on the Equipment Conventions Used in this Getting Started Guide Specifications RB-2X Bantam Plus RB-2X I/O Connection Operation Preparation Getting Started Thank you for your purchase Preparing Equipment for Use Registering Your Equipment Operational Considerations Product Features RB-2X Components and Controls Top Panel Touch Screen Display Operations Overview Setting the Bantam Plus Powering on the Unit Powering on the Unit in the Field Conducting a Meter Test with the Bantam Plus Integrated Socket Meter Test using Meter Test Adapter (RB-MTA) option RB-2X Administration Application...35

4 5.1 Administration Application Overview RB-2X Utilities Application Utilities Overview RB-2X Site Information Application Site Information Application Overview Routine Maintenance and Service Contact Information Routine Maintenance Service Service Warranty Service After-Warranty Service Helpful Documentation and Resources...45 Bantam Plus Getting Started Guide v6 4

5 Table of Figures Figure 1 RB-2X Bantam Plus Portable Test System... 7 Figure 2 WATT-Net and Windboard Software Data Transfer Figure 3 RB-2X Bantam Plus Portable test system rear panel Nameplate containing equipment serial number Figure 4 RB-2X Bantam Plus Portable Test System Cooling Vents Figure 5 Bantam Plus Main Menu Screen Figure 6 Touch Screen Keyboard. 27 Figure 7 Numeric Screen Keyboard 27 Figure 8 Windows Screen Keyboard...27 Figure 9 Bantam Plus Screen Tour. 30 Figure10 Bantam Plus Meter Test Screen...31 Figure 11 Bantam Plus Meter Run Testing Screen Figure 12 RB-2x Administration View Figure 13 RB-2x Utilities Application View 36 Figure 14 Site Information Application View..38 Figure 15 View of the Meter Test screen with the Data View enabled to view or edit meter information..39 Figure 16 Removable Socket Liners..42 Bantam Plus Getting Started Guide v6 5

6 About This Getting Started Guide The RB-2X Bantam Plus Portable Test System is designed as a stand-alone meter test system. The product functionality can be extended through use of optional test adapters (see section 1.1) to accommodate different meter and CT test applications. Use this getting started guide for the RB-2X Bantam Plus Portable Test System to perform the tasks shown below. Additional guidance and documentation can be obtained by reviewing the Bantam Plus Operations Manual. Test Meter Accuracy Perform a Standards Compare. Edit Meter Test Forms and Assign Operator Profiles Read results Transfer Meter Measurement data to an external controller. 1 Product Introduction and Specifications This chapter provides an introduction to the RB-2X Bantam Plus Portable Test System and contains the following sections: 1.1 Product Overview 1.2 Optional Accessories 1.3 Product Features 1.4 Safety Information 1.5 Specifications 1.1 Product Overview The Bantam Plus Portable Test System is designed for fast and accurate testing of electricity meters. The Bantam Plus combines advanced capabilities of an automated meter socket, the accuracy of a Radian reference standard as well as the embedded Winboard automated test software to provide a lightweight, easy-to-use test system. Bantam Plus Getting Started Guide v6 6

7 The RB-2X Bantam Plus Portable Test System consists of the main components shown below in Figure 1. Automated Meter Test Socket Sensor Pro Infrared and Visible Light optical sensor Interface panel to access external sensors, computer peripherals & options. Touch Screen color display Status Indicators Sound control keyboard Figure 1 RB-2X Bantam Plus Portable Test System Bantam Plus Getting Started Guide v6 7

8 1.2 Optional Accessories Optional accessories and routine maintenance kits are available for the Bantam Plus these include the following: RB-MSA RB-MTA Meter Socket Safety Power Adapter Simply pull the meter and insert the safety adapter into the exposed meter socket. Adapter faceplate voltage banana sockets provide easy access to service voltage. Meter Test Adapter An assembly that plugs into the Bantam Plus meter socket and delivers voltage and current (20 Amps max) to the meter test socket.(see section 4.2.2) RB-FPC RB-2x Field Power Cable An eight foot length of three core cable terminated with alligator clips and banana plugs to connect to meter socket service volts. RB-IRDS IR /Visible LED/Laser Disk Sensor, Band Mount The most versatile three in one meter pulse sensor assembly enables meters to be tested in the socket. RB-OPTOCOM OPTOCOM Optics Kit Port 1 Used for meters that requires communication via Optocom interface. Bantam Plus Getting Started Guide v6 8

9 RB-MOUNT Frame mount for Mechanical meter orientation and wall mount capability. RB-MECH RM-1S 90 Degree Adapter for mechanical meters The RM-1S Remote Reset Switch is a normally closed push button switch. The push-button has a tactile feel to provide instantaneous feedback of switch actuation. RB-MAG Magnetic Mount Optics Kit RB-BPH Back Pack carry harness RB-BAG Nylon Accessories Bag 12(l) x 8(h) x 5(w) inch. Bantam Plus Getting Started Guide v6 9

10 RB-KYZIO Advance I/O KYZ Breakout Cable Connects to Bantam Plus KYZ port. RB-BARCODE Serial Barcode Scanner Collect Meter Faceplate information and run meter tests automatically from a barcode scanner. RB-SCI RB-SCA RB-SMK RB-2x to RS Calibration System Interface Kit Used for interface to a Radian Syntron System for calibration purposes. RB-2x to RD-2x Standards Compare Adapter Used to interface with an external RD for calibration purposes. RB-2x Socket Maintenance Kit Contains pack of six field replacement socket assemblies and one Torx drive. RB-SCRN RB-2x Replacement Screen Shield Damaged or badly scratched screen protectors are field replaceable. RB-TSBR1 (Supplied with RB- TSJ) RB-TSJ Test Switch Interface Adapter with Burden and Ratio Testing An adapter that plugs into the Bantam meter socket. Provides access to clamp probes and direct secondary current for CT measurement. Test Switch Current Jumper Kit (Supplied with RB-TSBR1) Bantam Plus Getting Started Guide v6 10

11 1.3 Product Features RB-2x Portable Test System The RB-2x Bantam Plus Portable Test System offers the following features: Integrated automated meter test socket. Integrated pulse sensor. 3 Phase Test Current Output: 0.2 to 50 Amps. Phase control: in 0.05 steps. Synthesized Voltage Output: 69 V to 480 V. Integrated PC controller running Winboard software. Supported Meter Forms - 1S, 2S, 3S, 4S, 5S, 6S, 8S, 9S, 10S, 12S, 13S, 14S, 15S, 16S, 25S, 26S, 29S, 35S, 36S, 45S, 46S, 56S, 66S, 96S Optional CT, Burden testing. Lightweight RB-2X Embedded Winboard Software The RB-2X Winboard Automated software is used to run tests, assign sensors, set meter form test sequences and view and store test results. The RB-2X Winboard Automated Software offers the following features: Touch Screen interface USB and Ethernet Interface Create/Edit test sequences for meter forms Align Optics Standards Compare test routines Storage capacity is limited by the installed 120GByte solid state hard drive. Create/Edit test reports Maintain customer records Bantam Plus Getting Started Guide v6 11

12 1.4 Safety Information Review the information in this section to avoid injury and prevent equipment damage. The Bantam Plus was designed with safety in mind. The RB-2X socket will not energize unless a meter is first installed. An Interlock switch will disable the sources should a meter inadvertently be removed from the socket General Safety Summary! WARNING The operation of this equipment requires training and experience in electric meter testing. The information in this getting started guide is designed to supplement existing knowledge and experience already attained and practiced by journeyman-level meter test technicians. Meter Technicians classified as beginners should not attempt to operate this equipment without first gaining the basic knowledge of meter testing and the application of meter testing equipment from a certified training course. Operation of this equipment involves high voltage. Always wear the appropriate personal protective equipment and follow all safety precautions specified for high voltage activities. Follow proper grounding techniques when using this equipment. Follow all safety guidelines contained in this getting started guide.! CAUTION Do not use this equipment for any purpose other than for which it was designed. Do not operate the equipment outside of the environmental conditions specified in this getting started guide. Do not operate this equipment with covers or panels removed. Keep equipment surfaces clean and dry. Handle the RB-2X Bantam Plus Portable Test System with care; it is a precision instrument. Inspect the equipment before each use. Do not use the equipment if damage is observed. Use only cables provided by Bantam Plus Getting Started Guide v6 12

13 1.4.2 Symbols Found on the Equipment The following safety symbols appear on the RB-2X Bantam Plus Portable Test System: Danger of electrical shock. Warning: Refer to Getting Started Guide or Operations Manual Conventions Used in this Getting Started Guide The following conventions are used in this getting started guide to highlight important information:!! WARNING CAUTION NOTE Indicates an imminently hazardous situation that can result in death or a serious injury. Indicates a potentially hazardous situation that can result in an injury or equipment damage. Indicates important information you should review before proceeding. Bantam Plus Getting Started Guide v6 13

14 1.5 Specifications RB-2X Bantam Plus Operational Supply voltage Test current 90 to 300VAC, 60 Hz Phase A to 50 A (limited to 20 Amp when using optional RB- MTA test adapter) Accuracy RB-20: 0.04%, RB-21: 0.02% Physical Size Weight Warranty Height: 14.4 in (370 mm) Width: 10.2 in (260 mm) Length: 20.4 in (520 mm) 31.5 lbs (14.29 kg) 2-year warranty against defects in material or workmanship; care plans are available to extend warranty Electrical Protection Line power: 5 A Breaker Reference standard: Contains internal fuses, not accessible to operator. Environmental Temperature range 10º to 50º C (-4º to 122º F) Relative humidity 5 95% Shock and vibration Any which is nondestructive Water resistance Not airtight or watertight Supplied Cable Length Cable type 10 ft RB-SPC Shop Power Cable & RB-FPC Field Power Cable terminated with alligator clips Three core power cable with ground Bantam Plus Getting Started Guide v6 14

15 1.5.2 RB-2X I/O Connection The I/O connection panel contains three different connectors, each suited to a particular type of optics for external meter test. NOTE Pulse Port 2 is assigned to the onboard sensor. Inserting an external sensor will bypass the onboard sensor. The onboard sensor Port 1 is default unless the test sequence is changed to reflect Optics Port 2 or Port 3. Port 1 Is reserved for an Optocom* Optics (Model RB- Optocom) cable. Optocom Optics allows the operator to not only detect pulses from solid state meters, but also allows the operator to program the meter without changing the optical head. *Optocom is a registered trade mark of Optocom Corporation. Port 2 Port 3 A LEMO connector reserved for optical accessories including suction-cup based reflect and solid state optics. A BNC connector reserved for an optional click-switch adapter RB-CLICK or an optics sensor with BNC termination. The BNC connector is also used when conducting a standards compare test. AUX The AUX port is designed for connection to optional socket adapters including the RB-TSBR1 CT Ratio & Burden adapter. Advanced I/O This connector is assigned for testing meters with KYZ (Model RB-KYZ10). The Advanced I/O connector provides many capabilities for the testing of solid state meter. It can Bantam Plus Getting Started Guide v6 15

16 accommodate up to six Form A contact inputs or four Form C and two Form A contact inputs. For outputs, it has one programmable output allowing 0.01 to 40 seconds between contact transitions and a quantity of pulses (1 to 4094) to output. In addition two outputs can be software set high or low. There is also an unregulated 12VDC output. The following illustration depicts the connection diagram of the advanced I/O connector. IOIOIO A serial port used for external peripherals and options including bar code readers. USB Two USB connectors are available for use with peripherals including memory drives, remote keyboard or mouse, wireless adapters, etc. Ethernet 10/100 Ethernet connection that can be used to connect the Bantam Plus to a local area network. Bantam Plus Getting Started Guide v6 16

17 2 Operation Preparation This chapter provides information on preparing to use your RB-2X Bantam Plus Portable Test System and contains the following sections: 2.1 Getting Started 2.2 Operational Considerations 2.1 Getting Started Thank you for your purchase Thank you for purchasing this quality product. Radian reference standards are recognized throughout the world for their unparalleled accuracy, precision, and stability. We have taken every effort to ensure that your RB-2X Bantam Plus Portable Test System reaches you in perfect condition. Your satisfaction is very important to us, and your continued loyalty is greatly appreciated. If for any reason your Radian product does not meet your expectations of exceptional performance, please contact your sales representative or Radian Research, Inc Fortune Drive Lafayette, IN USA Tel: (765) Fax: (765) Website: Bantam Plus Getting Started Guide v6 17

18 2.1.2 Preparing Equipment for Use Follow these steps to prepare your RB-2X Bantam Plus Portable Test System for use. 1. Unpack and inspect: Carefully remove the equipment from the packaging, and check for any signs of damage. NOTE If you observe any damage to the equipment, immediately notify the carrier and your sales representative. 2. Verify the contents: The following items are included in your shipment: o RB-2X Bantam Plus o RB-SPC-10 Shop Power cord and RB-FPC-10 Field Power cable terminated with alligator clips. o Carry Handle with Folding Cover o WATT-Net PC Software (Base) CD and Getting Started Guide ( see Figure 2) o Calibration report(s) o Bantam Plus Getting Started Guide o Optional accessories (maybe packaged separately) (see Section 1.2 ) Bantam Plus Getting Started Guide v6 18

19 3. Information about your equipment software: Your new Bantam Plus is shipped with Winboard software installed. In addition, the Bantam Plus will arrive with a WATT-Net PC Software (Base) CD when installed on an external PC can be used for import/export data management. This base software is supplied with generically define fields. If you wish to customize the fields or are already using WATT-Net within your organization you may purchase optional customization packages. For more information on customization contact your Radian representative or Radian directly at NOTE If you intend to purchase optional software database customization this should be done before you begin to export data from your Bantam Plus. Integrating export data collected post optional database customization may result in lost data. (see section ) Figure 2 WATT-Net and Winboard Software Data Transfer Bantam Plus Getting Started Guide v6 19

20 4. Register your equipment (see Section 2.1.3, Registering Your Equipment) to: Activate the equipment warranty. Receive firmware and software updates as well as product application notes from NOTE You must register your equipment at to activate the twoyear equipment warranty. If you do not activate the warranty, the warranty period is limited to one year. Bantam Plus Getting Started Guide v6 20

21 2.1.3 Registering Your Equipment Follow these steps to register your RB-2X Bantam Plus Portable Test System: 1. Navigate to 2. Complete the online form. The model number is either RB-20 or RB-21 and is found on nameplate. The serial number can be found on the nameplate as shown in Figure 3. ON/OFF Double pole 5 Amp Breaker Switch Line & Ground Input, 300 VAC max. Model & Serial Number Label Figure 3 RB-2X Bantam Plus Portable test system rear panel nameplate containing equipment serial number Bantam Plus Getting Started Guide v6 21

22 2.2 Operational Considerations To protect the RB-2X Bantam Plus Portable Test System and ensure optimal performance, follow these guidelines: Placement: When placing the RB-2X Bantam Plus Portable Test System for use, avoid very wet or dusty environments.! CAUTION Electrical Shock hazard if equipment is exposed to water during operation. Cooling: When placing the RB-2X Bantam Plus Portable Test System for use, do not block the cooling vents on the front and back as shown in Figure. NOTE The RB-2X cooling fan is temperature controlled and will only operate when the internal temperature exceeds a preset threshold and before damage can occur due to excessive overheating. Periodically inspect and clean the air filter found at the front of unit. Power: The RB-2X Bantam Plus Portable Test System requires a source capable of providing at least 250 W of continuous power to operate correctly. Periodically inspect and clean removable filter Figure 4 RB-2X Bantam Plus Portable Test System Cooling Vents Bantam Plus Getting Started Guide v6 22

23 3 Product Features This chapter provides detailed information on the product features of the RB-2X Bantam Plus Portable Test System and contains the following sections: 3.1 RB-2X Components and Controls 3.2 RB-2X Automated Software Controls 3.1 RB-2X Components and Controls Top Panel The components of the RB-2X Bantam Plus Portable Test System top panel are explained below. 1. Line Voltage ON/OFF 5 Ampere Breaker Switch: Used to power and protect the Bantam Plus.! CAUTION NOTE The input voltage operating range is 90V to 300V. The design will source 69V to 480V to the meter socket. Breaker switch is rated at 5 Amps. The Bantam Plus software operating system must be shut down before powering off the unit. 2. Front Panel Power indicator: Indicator light that glows blue when the RB-2X Bantam Plus power is on.! CAUTION Always check the service voltage before connecting the test cable. Connecting the equipment to an improper voltage will trip the breaker and can result in equipment damage. 3. Front Panel Voltage & Current Indicator: Red and Yellow LEDs will activate when Voltage and/or Current is applied to the integrated meter socket. Bantam Plus Getting Started Guide v6 23

24 4. Pulse Detection Indicator: LED will flash green when a meter pulse is detected. A visible pulse sensor detection LED is duplicated within the integrated sensor head. 5. Volume Control: The Volume Control Keyboard is used to control the volume of the audible pulse the unit generates to echo pulses detected when conducting a meter test. The keys on the left and right lower and raise the volume respectively. Pressing the mute key will light the blue LED within the key indicating that the unit is muted. 6. Ports 1, 2 & 3: Ports 1 thru 3 are each suited to a particular type of optics. The connector "port 1" is reserved for an Optocom (RB-Optocom) cable. Optocom Optics allows the operator to not only detect pulses from solid state meters, but also allows the operator to program the meter without changing the optical head (external PC required). This connector may also be used for custom pickups as required. Contact Radian for any special needs that may not be met by the standard set of pickups. Port 2 is a BNC connector reserved for a wide variety of optional optics accessories, including clamp-on and suction-cup based reflect solid state optics. During normal testing when Input 3 is not the source this connector also outputs a test pulse for calibration purposes. Port 3 is a BNC connector reserved for an optional click-switch adapter that is used when other optics aren't suitable. The BNC connector is also used when conducting a standards compare test. The red LED on the integrated Sensor Pro TM optics sensor provides a visual indication that the unit has detected a pulse. NOTE An external sensor connected to Port 2 will disable the Sensor Pro TM optics on board. Bantam Plus Getting Started Guide v6 24

25 7. Advanced I/O: The Advanced I/O connector provides many capabilities for the testing of solid state meter. It can accommodate up to six Form A contact inputs or four Form C and two Form A contact inputs. For outputs, it has one programmable output allowing 0.01 to 40 seconds between contact transitions and a quantity of pulses (1 to 4094) to output. In addition two outputs can be software set high or low. There is also an unregulated 12VDC output. 8. Serial Interface: The RS232 serial interface connector is a multi-function input connector that can be used for a variety of accessories including a barcode scanner. 9. USB Interface: USB ports located one above the other. These can be used for connecting an optional keyboard, mouse or other USB device. 10. Ethernet Interface: A 10/100 Ethernet connection that can be used to connect the Bantam Plus to a local area network. This can be very useful for transferring test results from the Bantam Plus to a central database. Bantam Plus Getting Started Guide v6 25

26 3.1.2 Touch Screen Display Applications that are grey will go active when hardware option is fitted. Alternative methods for selecting a meter test Administration Application Refer to Section 5 for more information. Site Information Application It is not necessary to use Site information to run a test. Refer to Section 8 Edit Profiles Application Refer to Section 5 for more information Utilities Application Refer to Section 6 for more information Figure 5 Bantam Plus Main Menu Screen The Bantam Plus touch screen allows you to make selections in the software without the need for a keyboard or mouse. Touch the display to make selections, or even type in data using the touch screen keyboards (see Figures 6,7,8). NOTE The display virtual buttons used to interact with the Bantam Plus software are set to single click. It is not necessary to "double click" to activate programs, activate buttons or otherwise interact with the unit. To perform a right click using a stylus, Click stylus to the touch screen and hold it in place for a few seconds. Bantam Plus Getting Started Guide v6 26

27 Figure 6 Touch Screen Keyboard Figure 7 Numeric Screen Keyboard Figure 8 Windows Screen Keyboard Bantam Plus Getting Started Guide v6 27

28 4 Operations Overview This chapter provides general instructions for using the RB-2X Bantam Plus Portable Test System and contains the following sections: 4.1 Connecting the Bantam Plus 4.2 Conducting a Meter Test with the Bantam Plus 4.1 Initializing the Bantam Plus Powering on the unit To Power up the Bantam Plus using the Shop Power Cord: 1. Ensure the ON/OFF Breaker Switch on the rear panel is in the OFF position. 2. Connect the green ground wire coming from the Shop Power Cord through the ground terminal and tighten down the terminal. Make sure the ground cable is secure before continuing. 3. Plug the two black banana plugs coming from the Power Cord into the banana sockets on the rear panel of the Bantam Plus. NOTE Live and Neutral orientation is not important as supplies are fully isolated and fused on both neutral and live. 4. Insert the plug end of the Shop Power Cord into a 90V-300V grounded outlet. When switched ON the software will automatically launch. Since the internal PC will have to boot up, it may take a few seconds for the unit to launch the control application Powering on the unit in the field In the field you can use the Field Power Cord and Field Safety Ground Cable to draw power directly from the meter test switch. To do so: 1. Open all the test switches. 2. Make sure the potential is between 90 and 300 volts 3. Connect the green Field Safety Ground Cable through the ground terminal and tighten down the terminal. Make sure the ground cable is secure before continuing. Bantam Plus Getting Started Guide v6 28

29 4. Plug the black cable coming from the Field Power Cord into the black connector on the rear panel of the Bantam Plus. 5. Clamp the Field Safety Ground Cable to the meter block ground lug. 6. Clamp one lead from the Field Power Cord onto the neutral lower side test switch. Clamp the other lead from the Field Power Cord onto the phase A lower side test switch. 7. When the last connection is made and the switch/breaker is turned on the unit will power up and the Bantam Plus software will automatically launch. NOTE Always disconnect the ground connector last. Failure to do so can result in equipment damage or personal injury. Bantam Plus Getting Started Guide v6 29

30 4.2.1 Conducting a Meter Test with the Bantam Plus Integrated Socket NOTE The test procedure described below assumes the meter is removed from the meter socket and inserted into the Bantam Plus integrate socket and the internal Sensor Pro optic sensor is used. For detailed explanation on using Bantam Plus to test meters in the meter panel using the optional RB- MTA see section Follow these steps to conduct a Form 2S Meter test with the RB-2X Bantam Plus Portable Test System: 1. Power the Bantam Plus using the instructions described in section or You will hear an audible tone three times from internal RD Reference Standard during power-up this indicate the internal reference standard is operational. 2. See Figure 9 for a Bantam Plus screen tour. Profile TAB accesses addition profile pages. A maximum of 30 profiles can be assigned by the operator. 3. For the purpose of this exercise we will assume no Profiles have been created. Select METER TEST Select Main Menu Tab to view additional Administration and Utilities Application Icons Profile keys are short cuts to pre-assigned meter information. Meter information can be assigned to each Profile from the Edit Profile key and stored in non volatile RAM. Select Meter Test to bypass a Profile and run a meter test Before powering down the Bantam Plus Select Shutdown to exit Windows Figure 9 Bantam Plus Screen Tour Bantam Plus Getting Started Guide v6 30

31 4. Bantam Plus will implement an initialization sequence. Before proceeding with a meter test validate the Kh is correct for the meter under test. The optics should now be aligned. Select a Meter Test Test Sequence; Multiple test can be created. E.g. Demand Test, Quick Test, Default, etc. Use Form Drop down menu to select 2S Meter Adjust Optics Review Status line information before and during a meter test ensures Bantam Plus is ready and operating correctly. Figure 10 Bantam Plus Meter Testing Screen NOTE The integrated Sensor Pro is designed to accommodate meters with very low level pulse emission or during operation in bright sunlight. For optimal sensitivity position sensor head 1 inch between the Meter glass and the sensor. Use the target on the Sensor Pro to assist in alignment. 6. The integrated Sensor Pro is assigned to Optics 2 (Port 2). Select Adjust Optics button from the screen soft menu. Physically align the Sensor over the Meter Pulse output. During alignment view the flashing Red LED in the rear of the Sensor Pro head for visible activity. Bantam Plus Getting Started Guide v6 31

32 NOTE A secondary Pulse LED can also be viewed on the display bezel. Pulses are also registered using an audible beep. Un-mute and increase the volume using the Bantam Plus keypad found below the display. For high Kh the sensor pulse duty cycle maybe long. 7. Once the sensor is aligned the meter is ready to begin testing. 8. Validate the Meter form and Kh value is correct. Review the test sequence for appropriate steps before selecting the Start soft key. 9. Select start and validate the Voltage and Current LEDs on the front display bezel are active. Test Pointer indicates actual test being performed As found, As Left measurement results. Green indicates Pass, Red fail declared specification Indicate source Voltage, Current and Phase applied to meter Revolutions or Pulses remaining in current test Step. Status bar will indicates test status Figure 11 Bantam Plus Run Test Screen Bantam Plus Getting Started Guide v6 32

33 NOTE If a run is repeated the data from a second test will populate the AS LEFT field. 10. To cancel a meter test at any time select CANCEL from the display softkey. 11. Results may be viewed from the Administration Application see section 5.1 Bantam Plus Getting Started Guide v6 33

34 4.2.2 Meter Test using Meter Test Adapter (RB-MTA) option. NOTE The optional MTA Adapter is designed for testing Transformer rated meters while housed within a meter socket Meter Test Adapter RR-MTA To test a Transformer rated meter using the following steps; 1) Connect the Bantam Plus Ground connection to a suitable ground at the Meter housing assembly. 2) Connect the RB-Field Power cable to the service voltage ensuring not to exceed 300V. 3) Before powering on the Bantam Plus ensure that the Meter Test Adapter is inserted into the Bantam Plus meter socket. Orientation of the MTA to the socket is important; The MTA is keyed and will only fit with the cables facing to the rear of Bantam Plus. Furthermore, the Bantam Plus has a safety interlock and requires correct orientation for operation. 4) Connect the RB-MTA alligator clips to the meter test switch. Care should be taken to ensure the elements are correctly matched for the meter under test and the meter test switch used. For more details on the different meter forms and their pin outs refer to the MTA Connection Guide. 5) Connect a suitable external pulse sensor to either Port 1, 2 or 3. 6) Power ON the Bantam Plus and wait for initialization. 7) Select the appropriate Meter Form and test sequence. 8) Begin Adjust Optics Test from within the Meter Test Application to align the external pulse sensor to the meter. 9) Select Start to begin meter test. 10) On completion of meter test power down the Bantam Plus and remove the cables from the meter test switch. 11) Finally remove the ground cable from the meter test box. NOTE The RR-MTA option is specified to operate to a maximum of 20 Amps. No damage will occur if >20 Amps is delivered. However, the cable length will have appreciable burden and may not deliver the full rated current. Bantam Plus Getting Started Guide v6 34

35 5 RB-2X Administration Application This chapter describes the Administration Application structure of the RB-2X and contains the following section: 5.1 Administration Overview 5.1 Administration Application Overview Figure below shows the Administration application screen. An overview of each function is summarized. Figure 12 RB-2X Administration View Edit Form Defaults: Bantam Plus is supplied with all ANSI forms already defined. Edit Forms allows you to customize settings for specific meter forms Edit Test Sequences: to view, add, edit, delete, import or export test Sequences View/Edit Test Results: allows the operator to access test results that have previously been saved to the Bantam Plus. Bantam Plus Getting Started Guide v6 35

36 5.1.4 Edit Customer List: allow you to build a customer list to keep track of test results for multiple meters with different ownership. Only test results saved for the current customer will appear in the View/Edit Test Results screen Edit DataView & Import Export Options: allow you to customize the data view screen and establish how to define custom field names for imported or exported data. Data import/export is performed using the supplied WATT-Net software Edit Drop Down Code: is used to customize the valid values associated with a field defined in the Edit DataView and Import/Export Setting screen. An example of codes defined in the Edit Drop Down Codes screen would be a list of valid manufactures that can be selected at the test time from a drop down list Edit Barcode: screen provides access to the editors necessary to set up the Bantam Plus barcode reading functionality. From the Edit Barcode screen you can edit the barcode table, define custom barcode labels, and edit manufacturer codes Edit Meter Setup: screen allows you to customize many important power generation functions Options: screen allows you to change the displayed color scheme and Network Options including TCP/IP address. Bantam Plus Getting Started Guide v6 36

37 6 RB-2X Utilities Application This chapter describes the Utilities Application structure of the RB-2X and contains the following section: 6.1 Utilities Overview 6.1 Utilities Overview Figure 13 below shows the Administration Application screen. An overview of each function is explained. Figure 13 RB-2X Utilities Application view Bantam Plus Getting Started Guide v6 37

38 6.1.1 Standards Compare: allows the operator to perform an automated comparison of the Bantam Plus internal reference with an external reference standard. Option RB-SCA will be required for this function. For more detail on how to perform a Standards Compare view the video posted at Run Sinewave Editor: Bantam Plus generates sine waves with low THD. To simulate real world phenomena the source is capable of generating harmonics from the voltage current source. Load and save waveforms. Once a waveform is created it must be loaded to replace the sine wave table External RD Comm: enables an external PC to communicate directly with the internal Reference Standard Remote Control Desktop Settings: enables a remote desktop to control the Bantam Plus via Ethernet Remote Assistant: enables operator to request remote assistance Updates Back-up and Restore: enables the operator to check for software & firmware update, restore Windows settings, back-up files.. Bantam Plus Getting Started Guide v6 38

39 7 RB-2X Site Information Application This chapter describes the Site Information Application structure of the RB-2X and contains the following sections. 7.1 Site Information Application Overview 7.1 Site Information Application Overview Figure 14 below shows the Site Information screen. It is not necessary to set up information for a site, but doing so can greatly streamline your meter testing workflow. Site information is a collection of data specific to a location where a meter or meters, current transformer, potential transformer, or combination of these is regularly tested. You enter the information associated with a site once and then load the site before a test so that the information is automatically populated in the necessary fields throughout the various testing screens. Confirmation of Site Information, including ability to add meter's serial number, can be viewed by selecting the Data View key found in the Meter Test Window, reducing or negating the need for input from the operator. Figure 14 Site Information Application View Bantam Plus Getting Started Guide v6 39

40 7.1.1 Edit Site Information: allows the operator to add or edit site information Load Site Information: allows the operator review, edit previously saved site information Site Report: allows the operator to select, review and print a site report. Access to Data View screen Toggle key to change appearance of Data View screen. Figure 15 View of the Meter Test screen with the Data View enabled to view or edit Meter information. Bantam Plus Getting Started Guide v6 40

41 8 Routine Maintenance and Service This chapter contains the following sections: 8.1 Contact Information 8.2 Routine Maintenance 8.3 Service 8.4 Helpful Documentation and Resources 8.1 Contact Information For questions related to maintenance and service, contact : 3852 Fortune Drive Lafayette, IN USA Tel: (765) Fax: (765) radian@radianresearch.com Website: Routine Maintenance The RB-2X Bantam Plus Portable Test System is requires the following routine maintenance: Frequency Activity Before each use Inspect the test cable for damage. Check the air filter is clean. Before storing the equipment Wipe exterior surfaces with a dry, soft cloth to remove dust and dirt. Do not use solvents to clean plastic surfaces. Yearly Calibrate the Bantam Plus. Bantam Plus Getting Started Guide v6 41

42 8.3 Service Service The Bantam Plus equipment is designed for testing meters and used as part of your organization's quality control system. The procedure below outlines the limited parts that are customer replaceable. Over extended use, the current carrying socket jaws may foul with contaminates such as oil or grease and no longer produce the contact necessary to operate to specification. The following procedure describes how to periodically clean or replace these jaws. Remove the five Torx screws to expose the socket assembly Step 1. Ensure the Bantam Plus is switched off and isolated from line voltage. Step 2. Remove the five Torx drive screws from the socket cover. Step 3. Remove the socket cover to expose the socket assembly. Step 4. Note that each current conductor has a replaceable liner. Clean each liner using compressed air being careful that all loose debris is removed. Should oil be present remove the liner from the Bantam Plus before using an oil solvent for cleaning. Bantam Plus Getting Started Guide v6 42

43 Step 5. If necessary liners can be replaced using of RB-SMK Socket Maintenance Kit available from Radian Research. Step 6. Before replacing the socket assembly cover ensure that the socket assembly dividers found on the base of the socket assembly cover sit either side the voltage conductors. Failure to do so could result in bending the voltage conductors preventing a meter insertion. Replace the socket assembly cover and retighten the five Torx screws. Step 7. Perform a Standards Compare to validate the performance using Standards Compare information found in section 6.1. Removable socket liners Figure 16 Removable Socket Liners! WARNING The RB-2X Bantam Plus Portable Test System produces high voltages and is serviceable only by qualified personnel. Attempts to service the equipment by unqualified personnel can result in personnel injury Warranty Service warrants that each product is free from defects in material and workmanship. Our obligation under this warranty is to repair or replace any instrument or component therein that, within two years after shipment and with normal use, proves to be defective upon examination. Bantam Plus Getting Started Guide v6 43

44 To Obtain Warranty Service All warranty returns must have a return materials authorization (RMA) number. To obtain an RMA, visit Follow these guidelines to ensure prompt warranty service: must authorize all warranty replacements. Ship returned items prepaid, fully insured, and in the original packing to minimize the possibility of damage. will not accept collect shipments and does not accept liability for damage caused by improper packing or handling during shipment. Include in the shipment a detailed description of the problem and the events that led up to the development of the problem. will pay local domestic surface freight costs to return the product to the customer. Radian will not pay for overnight or express shipping service. Use the following address for warranty returns: 3852 Fortune Drive Lafayette, IN USA Attn: RB-2X Service After-Warranty Service If after-warranty service by is needed: A purchase order is required. The owner must pay all shipping costs. If requested, can provide an estimate for the repair; however, if the repair is not made, the cost of labor required to obtain the estimate will be invoiced at the hourly repair rate. To Obtain After-Warranty Service All after-warranty service requests must have a return materials authorization (RMA) number. To obtain an RMA, visit Payment information must also be provided (purchase order or credit card). Please follow these guidelines to ensure prompt after-warranty service: Ship returned items prepaid, fully insured, and in the original packing to Bantam Plus Getting Started Guide v6 44

45 minimize the possibility of damage. Include in the shipment a detailed description of the problem and the events that led up to the development of the problem. will invoice return shipping costs to the customer. 8.4 Helpful Documentation and Resources Visit the Radian web site at: Bantam Plus Getting Started Guide v6 45

Research, Inc. About This Getting Started Guide

Research, Inc. About This Getting Started Guide Research, Inc About This Getting Started Guide makes no warranty on the accuracy of the information contained in this getting started guide and accepts no liability for its use. The information contained

More information

Research, Inc. About This Getting Started Guide

Research, Inc. About This Getting Started Guide Research, Inc About This Getting Started Guide makes no warranty on the accuracy of the information contained in this getting started guide and accepts no liability for its use. The information contained

More information

0Radian Research, Inc

0Radian Research, Inc 0Radian Research, Inc About This Manual makes no warranty on the accuracy of the information contained in this manual and accepts no liability for its use. The information contained in this manual remains

More information

WE-30. Portable Three-Phase Meter Tester/Analyzer

WE-30. Portable Three-Phase Meter Tester/Analyzer Portable Three-Phase Meter Tester/Analyzer WE-30 333 Crosspark Drive Pearl, Mississippi 39208 USA P: 601.933.0900 F: 601.933.0901 E: sales@watthour.com www.watthour.com Portable Three-Phase Meter Tester/Analyzer

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

Economy Single Channel Output DC Power Supply

Economy Single Channel Output DC Power Supply Economy Single Channel Output DC Power Supply User Manual www.owon.com.cn Feb. 2019 edition V1.1.0 Copyright LILLIPUT Company. All rights reserved. The LILLIPUT's products are under the protection of the

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS Pro 900 software Us er Documentation Installation and Operation Back-UPS Pro 900 Inventory Connect the Battery bu001a User Documentation (2) Safety and General Information Inspect the package contents upon receipt.

More information

Installation and Operation Back-UPS Pro BR700G-TW

Installation and Operation Back-UPS Pro BR700G-TW Installation and Operation Back-UPS Pro BR700G-TW Inventory Safety Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Do not connect a laser printer or hair

More information

Installation and Operation Manual Back-UPS BR900G-RS

Installation and Operation Manual Back-UPS BR900G-RS Installation and Operation Manual Back-UPS BR900G-RS Inventory Safety bu001a This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS Pro 900 Us er Documentation Installation and Operation Back-UPS Pro 900 Inventory bu001a User Documentation (2) Safety and General Information Inspect the package contents upon receipt. Notify the carrier and

More information

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface... General Warranty OWON warrants that the product will be free from defects in materials and workmanship for a period of 2 years (1 year for accessories) from the date of purchase of the product by the original

More information

Portable Three-Phase Meter Site Analyzer

Portable Three-Phase Meter Site Analyzer Three-Phase Customer Load Field Testing Portable Three-Phase Meter Site Analyzer Radian Research Reference Standard Accuracy Proven Portable Three-Phase Meter Site Analyzer RW-30X NS RW-31X NS tests,

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

Universal AC Power Source + AC Power Analyzer

Universal AC Power Source + AC Power Analyzer User's Guide Universal AC Power Source + AC Power Analyzer Model 380820 Introduction Congratulations on your purchase of the Extech Model 380820. This Universal AC Power Source and AC Power Analyzer can

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

User Manual Back-UPS BE650MC

User Manual Back-UPS BE650MC User Manual Back-UPS BE650MC Inventory Back-UPS ES 650 bu075b This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30

More information

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This

More information

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 3 years (1 year for accessories) from the date of purchase of the product by the

More information

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Portable Airborne Particle Counter (particle counter). This guide will

More information

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389 User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

Back-UPS RS 550 Installation & Operation

Back-UPS RS 550 Installation & Operation Back-UPS RS 550 Installation & Operation Inventory Safety Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. bu001a Do not connect a laser printer or hair

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A AC Clamp Meter. Model 38387 User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Radian Research, Inc.

Radian Research, Inc. About This Manual makes no warranty on the accuracy of the information contained in this manual and accepts no liability for its use. The information contained in this manual remains the property of It

More information

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation.

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols...

More information

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual SmartBoom Operating Manual PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U Thank You We at Pliant Technologies, LLC want to thank you for purchasing the SmartBoom PRO

More information

Model VT120 Fast Timing Preamplifier Operating and Service Manual

Model VT120 Fast Timing Preamplifier Operating and Service Manual Model VT120 Fast Timing Preamplifier Operating and Service Manual Printed in U.S.A. ORTEC Part No. 740360 1202 Manual Revision C Advanced Measurement Technology, Inc. a/k/a/ ORTEC, a subsidiary of AMETEK,

More information

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers Table of Contents Package Contents.............. 1 Warranty.............. 1 Installation.............. 2 Maintenance

More information

WE-20. Quick Start Guide For Operating The. Portable Three-Phase Meter Tester/Analyzer

WE-20. Quick Start Guide For Operating The. Portable Three-Phase Meter Tester/Analyzer Quick Start Guide For Operating The WE-20 Portable Three-Phase Meter Tester/Analyzer 333 Crosspark Drive Pearl, Mississippi 39208 USA P: 601.933.0900 F: 601.933.0901 E: sales@watthour.com www.watthour.com

More information

Service Instructions. Conductor 420

Service Instructions. Conductor 420 Service Instructions Conductor 420 Listed, File No. E195547 Input: 480 VAC, 50/60 HZ. (Operating range 380-480 VAC) 20 AMP MAX OUTPUT W/25 AMP FUSE Output: 0-90% of Input Voltage Table of Contents General

More information

actilib Library 2U Quick Start Guide

actilib Library 2U Quick Start Guide actilib Library 2U Quick Start Guide September, 2009 1 Contents 1 Contents...2 2 Warnings and symbols...3 2.1 Precautions...4 2.2 Product Warranty Caution...4 2.3 Rack stability...4 3 Unpacking the tape

More information

1-36V, 0-3A DC Power Supply

1-36V, 0-3A DC Power Supply 1550 1-36V, 0-3A DC Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service,

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

MANUAL Series ZOOM STEREO MICROSCOPE MANUAL

MANUAL Series ZOOM STEREO MICROSCOPE MANUAL MANUAL 3078 Series ZOOM STEREO MICROSCOPE MANUAL Distributed By: CONTENTS SAFETY NOTES... 3 CARE AND MAINTENANCE... 3 INTRODUCTION... 4 UNPACKING AND COMPONENTS... 4 COMPONENT DIAGRAMS... 5 ASSEMBLY...

More information

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1000 Part No. 23624 OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1000 OV1000 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications

More information

2016 SIGLENT TECHNOLOGIES CO.,LTD

2016 SIGLENT TECHNOLOGIES CO.,LTD Quick Strat SDM3045X Digital Multimeter QS06034-E01A 2016 SIGLENT TECHNOLOGIES CO.,LTD Copyright Information SIGLENT TECHNOLOGIES CO., LTD. All rights reserved. The information provided in this manual

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-KHV Kelvin Keithley Triaxial Connector Card Description The Model 8020-KHV Keithley HV Connector

More information

VBT-75 S2 VACUUM BOTTLE TESTER

VBT-75 S2 VACUUM BOTTLE TESTER VBT-75 S2 VACUUM BOTTLE TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 July 7, 2017 Revision 1 SAFETY

More information

Blue Weapon Laser. User manual UK. Version 1.0

Blue Weapon Laser. User manual UK. Version 1.0 Blue Weapon Laser User manual 152.754UK Version 1.0 CAUTION 15. Disposal : Please disposal of the unserviceable device according to the current statutory requirements. Please read this manual fully before

More information

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-STC Kelvin Standard Triaxial Connector Card Description The Model 8020-STC Kelvin Standard

More information

OPERATING INSTRUCTIONS. For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM. Serial Number: Leaflet Number G.

OPERATING INSTRUCTIONS. For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM. Serial Number: Leaflet Number G. OPERATING INSTRUCTIONS For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM Serial Number: Leaflet Number 2 015 G October 2016 Knopp Incorporated 1307 66th Street Emeryville, California 94608

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... 2 1.0 General Information... 3 1.1 System Components... 3 1.2 Specifications... 3 1.2.1 Torque Ranges... 3 1.2.2 Electrical Specifications...

More information

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1001 Part No. 23620 OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1001 OV1001 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.

More information

VADDIO /CANON BU-SERIES PTZ CAMERAS

VADDIO /CANON BU-SERIES PTZ CAMERAS Camera and Electronic Products for Integrators Installation and User Guide VADDIO /CANON BU-SERIES PTZ CAMERAS Canon BU-45H Outdoor & BU-50H Indoor PTZ Cameras including Vaddio accessories for easy integration

More information

D-Pack 6 Classic ORDERCODE 50315

D-Pack 6 Classic ORDERCODE 50315 D-Pack 6 Classic ORDERCODE 50315 Congratulations! You have bought a great, innovative product from Showtec. The Showtec D-Pack 6 Classic brings excitement to any venue. Whether you want simple plug-&-play

More information

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 ) Installation Manual 65 (64.56 ) Model: HILF65101 65 Interactive LED/LCD QUICK SETUP GUIDE For further information, see the user manual. Please contact directly if you have questions on the use of the touch

More information

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444 Product Manual 01504 (Revision B) Original Instructions RVDT Setup and Polarity Checking Tool for EG Governors T87444 Operation and Calibration Manual General Precautions Read this entire manual and all

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

Zonit μats TM Users Guide μats1-lv Version 1.2

Zonit μats TM Users Guide μats1-lv Version 1.2 Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational

More information

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Hardware Reference Guide For Thin Clients

Hardware Reference Guide For Thin Clients b Hardware Reference Guide For Thin Clients Document Part Number: 254241-001 July 2002 This book provides basic hardware information for this series of Compaq Thin Clients. Å WARNING: Ä CAUTION: 2002 Compaq

More information

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display Installation Manual Model: HILU750 '' Ultra HD Interactive Flat Panel Display QUICK SETUP GUIDE For further information, see the User Manual. Please contact HITACHI directly if you have questions on the

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL ANI-15115-08SWH PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: sales@a-neutronics.com

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

Tesla TI Generator Set Interface

Tesla TI Generator Set Interface Power Anytime, Anywhere Tesla TI2000-440 Generator Set Interface User Manual Built Smart...Proven Tough Tesla Industries, Inc. 101 Centerpoint Blvd. New Castle, DE 19720 (302) 324-8910 Phone (302) 324-8912

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

SIMATIC VPU Hardware Manual. Order Number: PPX:560/ Manual Assembly Number: Second Edition

SIMATIC VPU Hardware Manual. Order Number: PPX:560/ Manual Assembly Number: Second Edition SIMATIC VPU200 3104 Hardware Manual Order Number: PPX:560/65 8102 Manual Assembly Number: 2597773 0006 Second Edition ! DANGER DANGER indicates an imminently hazardous situation that, if not avoided, will

More information

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

Operations Manual. Model 622 UTEC Calibrator. Radian Research, Inc.

Operations Manual. Model 622 UTEC Calibrator. Radian Research, Inc. Radian Research, Inc. Model 622 UTEC Calibrator Operations Manual Radian Research, Inc. 3852 Fortune Drive Lafayette, IN 47905 USA Tel: 765-449-5500 Fax: 765-448-4614 www.radianresearch.com NOTICE...3

More information

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2 OPERATING PROCEDURES for the Universal Power Supply Series 2 Vanguard Instruments Co., Inc. 1520 S. Hellman Ave. Ontario, California 91761 TEL: 909-923-9390 November 2013 FAX: 909-923-9391 REV. 2 SAFETY

More information

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL SK-4033 / SK-4035 Thank you for purchasing KAISE MODEL SK-4033/4035 BENCH-TOP DIGITAL MULTIMETERS. To obtain the maximum performance of this instrument,

More information

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual SIMPLE LOGGER RMS CLAMP-ON MODULE CL600 E N G L I S H User Manual Owner s Record The serial number for the Simple Logger Model CL600 is located on the back of the instrument. Please record this number

More information

NI PXIe-1062Q Power Supply Shuttle

NI PXIe-1062Q Power Supply Shuttle USER GUIDE NI PXIe-1062Q Power Supply Shuttle The NI PXIe-1062Q power supply shuttle is a replacement part for the NI PXIe-1062Q chassis. Caution This power supply is not compatible with any other National

More information

User Guide. Control Box. RoscoLED TM.

User Guide. Control Box. RoscoLED TM. RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260

More information

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL MS-SL12-RD 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: sales@a-neutronics.com A-Neutronics.com

More information

HV-CS kv Edge Mount Triaxial Jack

HV-CS kv Edge Mount Triaxial Jack Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley HV-CS-1589 3 kv Edge Mount Triaxial Jack Installation Information Description The Keithley Instruments

More information

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO-1250D CT MID DIN rail three phase four wire energy meter. PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions

More information

True RMS AC Voltage/Current Datalogger

True RMS AC Voltage/Current Datalogger User's Guide True RMS AC Voltage/Current Datalogger Model DL150 Introduction Congratulations on your purchase of this Voltage or Current datalogger. With this meter, you can monitor and log data over long

More information

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Model 8010 High Power Device Test Fixture Interconnection Reference Guide Model 8010 High Power Device Test Fixture Interconnection Reference Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation. Although

More information

Owner's Manual RBC-5000

Owner's Manual RBC-5000 Owner's Manual RBC-5000 High Speed Bill Counter With Ultraviolet, Magnetic and Infrared Counterfeit Detection Royal Sovereign International, Inc. Please read and retain these instructions. To register

More information

MANUAL 3072 STEREO MICROSCOPE SERIES

MANUAL 3072 STEREO MICROSCOPE SERIES MANUAL 3072 STEREO MICROSCOPE SERIES 73 Mall Drive, Commack, NY 11725 631-864-1000 (P) 631-543-8900 (F) www.accu-scope.com info@accu-scope.com CONTENTS SAFETY NOTES... 3 CARE AND MAINTENANCE... 3 INTRODUCTION...

More information

TDM-170 TIMER DISPLAY

TDM-170 TIMER DISPLAY TDM-170 TIMER DISPLAY TECHNICAL MANUAL Version 1.1 August 2016 TDM-170 Timer Display Technical Manual Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions

More information

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL Model name: BMS-LSV6UL INTELLIGENT SERVER Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER. Please read this manual carefully beforehand for proper installation of the SERVER. NOTE This

More information

USER S MANUAL Linear Programmable DC Power Supply APS

USER S MANUAL Linear Programmable DC Power Supply APS USER S MANUAL Linear Programmable DC Power Supply APS-5333 www.tmatlantic.com Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols... 2 3. General Characteristics... 3 4. Quick

More information

RAINPROOF* COLOR CAMERA SECURITY SYSTEM

RAINPROOF* COLOR CAMERA SECURITY SYSTEM RAINPROOF* COLOR CAMERA SECURITY SYSTEM Model 91202 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com Copyright 2004 by

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

ENGLISH. User manual.

ENGLISH. User manual. ENGLISH User manual Copyright HT ITALIA 2012 Release EN 2.00-18/12/2012 Table of contents: 1. PRECAUTIONS AND SAFETY MEASURES... 2 1.1. Preliminary instructions... 2 1.2. During use... 3 1.3. After use...

More information

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Back-UPS RS APC Back-UPS RS 800VA 120V Black Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email

More information

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions Instruction Sheet 860508340 SYSTIMAX Solutions SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions General The SYSTIMAX 360 ipatch Network Manager module is a SYSTIMAX approved product. This

More information