Manual DTM Digital Pressure Transmitter

Size: px
Start display at page:

Download "Manual DTM Digital Pressure Transmitter"

Transcription

1 TetraTec Instruments GmbH Gewerbestr Steinenbronn Deutschland info@tetratec.de Tel.: 07157/ Fax: 07157/ Manual Digital Pressure Transmitter *** VERSION 1.1 *** Update:

2 Manual PART-NO.-STRUCTURE...3 TECHNICAL DESCRIPTION...4 SPECIFICATIONS...4 PIN ASSIGNMENT...5 MOUNTING...5 COMMUNICATION WITH THE DIGITAL TRANSMITTER...6 COMMAND LIST...8 DIMENSIONS...10 page 2 _man_e.doc

3 Manual PART-NO.-STRUCTURE Part-No.-Structure: -PT-PL-PC-EC-IF-AC-TR PT Pressure Type 281 Gauge pressure 282 Absolute pressure (vacuum) 283 Overpressure PL Press. Limit. PT Press. Limit. PT Press. Limit 00 0,10 bar 07 2,5 bar bar** 01 0,16 bar 08 4,0 bar bar** 02 0,25 bar 09 6,0 bar bar** 03 0,40 bar 10 10,0 bar bar** 04 0,60 bar 11 16,0 bar bar** 05 1,00 bar 12 25,0 bar bar** 06 1,60 bar bar** bar** PC Process Connection 00 G 1/4 f 11 G 1/4 m 12 G 1/4 m, for manometer DIN G 1/2 m 14 G 1/2 m, frontal diaphragm 15 G 1/2 m, flush diaphragm 16 G 1/2 m, for manometer DIN G 1/2 m 10 1/4" NPTm 19 1/2" NPTm EC Electrical Connection 01 Connector, screwable, DIN (IP 65) 03 Connector, not screwable, Type Binder 723 (IP 67) 43 Connector, screwable, Type Binder 723 (IP 67) 13 PE cable (IP 67) 15 PUR cable (IP 67) 21 Teflon cable (IP 67) IF Interfaces 61 RS-232C 62 RS-485 AC Accuracy 0 ±0,5 % F.S. 1 ±0,25 %F.S. 2 ±0,1 % F.S. (from measuring range 0.. 0,6 bar) TR Temperature Range Media Temperature (compensated) (permissible) C C C C C C ** Sealed gauge sensors for upper range limits from 40 to 1000 bar, specific ranges and other connection options, as well as accessories and services, on request. _man_e.doc page 3

4 Manual TECHNICAL DESCRIPTION The series are digital pressure transmitters to measure gauge, absolute (vacuum) or overpressure. Available are measuring full scale ranges from 100 mbar up to 1000 bar. Their robust and compact design qualifies them for the usage under adverse conditions. Beneath the manifold of different pressure connections there are the interfaces RS-232C and RS-485 chooseable. SPECIFICATIONS Sensor Type Measuring Range Limit Values Gauge/ absolute or. overpressure: 100 / 160 / 250 / 400 / 600 mbar 1 / 1,6 / 2,5 / 4 / 6 / 10 / 16 / 25 bar Overpressure only 40 / 60 / 100 / 160 / 250 / 400 / 600 / 1000 bar Accuracy Pressure Range [bar]: 0,1 to 0,5 0,5 to 2 2 to 1000 Accuracy [%F.S.]: <0,25 <0,1. <0,1 Long-term stability: <4mbar <4mbar 0,2%F.S. Resolution [%F.S.]: 0,01 0,01 0,01 Integration time: Adjustable from 1 ms to 20 s Effects like hysteresis and repeatability included Temperature Conditions Storage: 0 to +50 C Operation: 0 to +80 C permissible Operation: -25 to +100 C permissible Operation: -25 to +150 C permissible Media Compatibility Gases, liquids and steamous media compatible with stainless steel. Overpressure Limits 3 bar for measuring range limit values up to 0,5 bar, 1500 bar for the 1000 bar version, each other 3x measuring range limit value. Enclosure Dimensions: 30 x 200 mm (ØxL*) Material Body: Stainless steel Diaphragm: Stainless steel Seal: EPDM / Kalrez Weight Total: 110 g Ingress Protection: IP 40, IP65 or IP67 *Length max. 200 mm. Dependent on version and connections Process Connection Alternatively (1 x): G 1/4 f, G 1/4 m, G 1/2 m, 1/4 NPTm or 1/2 NPTm (respectively out of stainless steel) Electrical Connection Binder 723, 5-pole and different connectors and cables chooseable Supply 24 VDC (5 to 30 V ), current consumption: <7 ma Supply by connector alternatively by cable. Interfaces Available for RS-232C or RS-485 interface page 4 _man_e.doc

5 Manual PIN ASSIGNMENT Pin assignment clockwise, beginning at notch with view on the plug connector: Pin assignment RS-485 Pin assignment RS-232 Pin 1 +RS485 TxD Pin 2 -RS485 GND Pin 3 +Vin +Vin Pin 4 GND GND Pin 5 Not Connected RxD Example for pin assignment for the RS485 interface connector cable. View: soldering side MOUNTING Safety Instructions Mounting and demounting by competent personnel only! Before starting work make sure that the measurement point is not under pressure. Make sure that no dangerous gases (poisonous, suffocative or inflammable) can discharge from the measurement point. Make sure that pressure range and supply voltage of the sensor are appropriate for your application. Required Tools Open-end wrench 27 mm Mounting Place Avoid mounting near interference sources (motors, pumps, valves, transmitters etc.) and heat sources - excessive vibrations or pressure peaks can corrupt the measuring signal or damage the sensor. Mount pressure sensors with measuring range < 1 bar with the process connector pointing downwards because they are calibrated in this orientation. Mounting the Pressure Sensor Clean the mounting hole. Remove the yellow protective cap from the sensor. Tighten the pressure sensor with approx. 37 Nm. Establish electrical connection. _man_e.doc page 5

6 Manual COMMUNICATION WITH THE DIGITAL TRANSMITTER RS232 Interface Communication with the (digital transmitter) is accomplished via a RS232 interface at 4800 or 9600 Baud, 8 bit, no parity, 1 stop bit. Only signal lines RxD, TxD and GND are used without software handshake. Commands to the are transmitted as ASCII strings and are terminated with a carriage return (<cr>, ASCII13). All control characters (< ASCII32) are ignored with the exception of <cr>. acknowledgements are also terminated with a <cr>. Each command to the results in an acknowledgement. Commands which do not result in a return parameter are confirmed by a * and <cr>. Commands which can not be interpreted by the are acknowledged by a # and <cr>. Consecutive commands are separated by delimiters. Legal delimiters are: colon, comma, period, blank. Only the first four characters of a command are significant and no differentiation is made between upper case and lower case characters. The following commands are thus identical: PRES:ZERO:1234<cr> pressure zero 1234<cr> pres,zero,1234<cr> In the description of the commands which follows (section 2), the significant characters are represented in capital letters. Communication with the connected to a RS232 interface can be established via any PC with the assistance of a terminal program. As an example, settings are described for the Hyper Terminal program (a Windows 95/98 option in the Accessories folder). HyperTerminal settings for Windows 95/98 1. Connect the to a serial interface 2. Start the HyperTerminal program. 3. Type in the dialog box for a Description of the connection and click OK. 4. In the next dialog box, select the COM-Port to which the is connected and click OK. 5. Set up the communication parameters as follows: Bits per second: 4800 or 9600 Data bits: 8 Parity: none Stop bits: 1 Flow control: none and click OK. 6. Choose Properties from the File menu, the Settings tab in the next dialog box, and click on ASCII Configuration. 7. Select and activate (tick) the following options: Echo typed characters locally Append line feeds to incoming line ends Wrap lines that exceed terminal width and then click OK twice. The terminal program is now configured and you can communicate with the. page 6 _man_e.doc

7 Manual RS485 Interface The is controlled by a bus capable RS485 interface. It is possible to link up to 31 (absolute- and gauge pressure sensors with different measuring ranges) together at the same time. The interface uses a differential two-wire signal (signal lines +RS485 and RS485) for data transmission at 4800 or 9600 baud, 8 bits, no parity, 1 stop bit. The commands for the are embedded into ASCII strings being terminated by a carriage return (<cr>, ASCII 13). All control characters (ASCII value less than 32) except <cr> are ignored. For every command sent to the an acknowledgement also terminated by <cr> is sent back. Composite commands have a separator. Allowed separators are colon, comma, point and space. Only the first four characters of a command are significant. Upper or lower case makes no difference, but the following description of the commands presents the significant characters in upper case. Considering also an address because of bus capable RS485 interface and a check sum to improve safety, the real commands are embedded into additional control characters (the quotes are not to be entered): Command to > AA Command : CC <cr> with the following key: Start character: > Address: AA Hexadecimal value of range 00 to FF (0 to 255). Is used to identify the sensor and is adjustable. Command: string from the list of commands Check sum: CC Hexadecimal value of range 00 to FF. The ASCII values of all characters between the start character and the check sum are summed up. Then the last two digits of the hexadecimal representation of this value are transmitted as check sum. Reply of Acknowledgement ( Data ) * AA * ( : CC) <cr> with the following key: Confirmation character Acknowledgement If the command could be interpreted a * is sent, if not a # is sent. Data: ( Data ) Only if the command could be interpreted data is sent back. Address: AA Confer Command to Check sum: ( : CC) The check sum is only calculated from the data and thus only exists if data is sent back. A separator is sent before the check sum. For communication with the with a RS485 interface, a suitable interface must be employed. _man_e.doc page 7

8 Manual COMMAND LIST Context of commands PRESsure? PRESsure:ZERO? PRESsure:ZERO <...> SAVE TEMPerature? INMOde:... ADDRess? ADDRess <...> SERIal? DESCription: Name DESCription? PRESsure:UNIT? Direct measurement PRES? TEMP? Reads the current pressure value Reads the zero value of the pressure Sets the zero value of the pressure (value of range to ) By this it is possible to zero the independently from the original calibration. Attention: The entered value is subtracted from the value corresponding to the applied pressure. The zero value is entered without decimal point. Example: PRES? Reads the current pressure value 11.5 returns 11,5 mbar PRES:ZERO Sets zero of the to 11,5 mbar 115 PRES? Reads the current pressure value 0.0 returns 0 mbar Save parameters permanently (RS485 address, zero value of the pressure, integration mode, name) Reads the current temperature value Sets the integration mode Reads the RS485 address Sets the RS485 address (value from 00 to FF) Reads the 6-digit serial number Sets the individual name, for example as the name of the measuring name. Any string of up to 20 characters can be entered. Reads the individual name. Reads the engineering unit of the pressure (e.g. mbar, mws) Read out the current pressure Read out the current temperature Integration mode For the pressure measurement one of three integration types can be selected: Simple average: Each pressure value returned is the average of N current INMO:PRES:1:<N> measurements (N=1 to 32000). Moving average: A pressure value returned is the average of 2(N-1) measurements (N=1 INMO_PRES:2:<N> to 7). The next value returned is calculated by removing the first value of these measurements and considering the value of the next (new) Weighted average: INMO:PRES:3:<N> Integration mode: INMO:PRES? measurement instead of it. Works like moving average, but before calculating the average the value of every pressure measurement is multiplied by a weighting factor of 1/2(N-1) (N=1 to 7). Reads the current integration mode for pressure measurement. For temperature measurement there is only one integration type available: Simple average: Each temperature value returned is the average of N measurements INMO:TEMP:<N> (N=1 to 32000). Integrations-Modus: Reads the current integration mode for temperature measurement. INMO:TEMP? page 8 _man_e.doc

9 Manual Zero pressure Zero pressure can be adjusted independently from the actual calibration. Enter zero pressure: PRES:ZERO <-32, ,000> Query zero pressure: PRES:ZERO? Note: The entered value is subtracted from the actual pressure measurement. Zero pressure is entered without a decimal point. Example: PRES? Read the pressure 11.5 measures 11.5 mbar PRES:ZERO 115 is calibrated to zero for 11.5 mbar PRES? Read the pressure 0.0 measures 0 mbar Miscellaneous IDN? Read out an identification string. Typical reply: STS V1.03 (9/99) SERI? Read out the 6-digit serial number. Typical reply: DESC description Enter an individual description. The name of the measurement point can be entered here, for example. Any string of up to 20 characters can be entered. DESC? Read out the individual description. PRES UNIT? Read out the unit of pressure (e.g. mbar, mws). Change the command set The can be addressed with a slightly reduced command set for the former STS s. The following commands are supported in the old command set: A Power up P Pressure mode T Temperature mode D Raw data M Measure S Serial number I <1...8> Enter integration rate N Zero Additional commands in the new command set: CMDT? Read out command set CMDT <0, 1> Enter command set; 0 = old command set, 1 = new command set SAVE Save configuration (mode, integration rate, zero and command set) I? Read out integration rate Changing the command set resets the integration rates and modes to a simple average with one measurement! _man_e.doc page 9

10 Manual DIMENSIONS ,8 WS 27 Dimensions in mm 12 page 10 _man_e.doc

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor DCT 5 Industrial Pressure Transmitter with RS85 Modbus RTU Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar output

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

Digital pressure gauge Data Sheet: DMM2.431.R1.EN Data Sheet: DMM.431.R1.EN www.aep.it Digital pressure gauge DMM is a digital pressure gauge made according to the most modern technologies to ensure a high level of reliability, versatility and practicality

More information

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO. LMP 08i Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mh O up to 0... 00 mh O Output signals wire:... 0 ma wire:

More information

Fusion of electronic pressure sensor and analogue display.

Fusion of electronic pressure sensor and analogue display. Fusion of electronic pressure sensor and analogue display. Pressure sensors www.ifm.com/gb/pg fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control

More information

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic

More information

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signals wire:... 0 ma wire: 0... 0 V others

More information

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software Calibration technology www.materm.si tel: 02 608 90 10 with model CPA2500 USB adapter and USBsoft2500 software WIKA data sheet CT 05.01 Applications Calibration service companies and service industry Quality

More information

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]

More information

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet

More information

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31 Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling

More information

Multi-range pressure and differential pressure transmitter

Multi-range pressure and differential pressure transmitter Page 1/6 Multi-range pressure and differential pressure transmitter Type 402005 Applications Ventilation Air conditioning Clean-room technology Flue draft mechanisms Filter monitoring Brief description

More information

PRESSURE TRANSMITTER

PRESSURE TRANSMITTER KS PRESSURE TRANSMITTER GEFRAN SAFETY GUARANTEE Main Features Ranges: from 1 to 1000 bar Nominal Output Signal: 4...20mA (2 wires) 0...10Vdc / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc / 1...5Vdc / 1...6Vdc

More information

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application P30-2 Pressure Transmitter Datasheet At a Glance *High Quality* 3 Years Warranty Premium Pressure Transmitter for gauge and pressure measurement with 3 years warranty High repeatability and long-term stability

More information

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display Model PSD-4 Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine

More information

ProcessCalibrator Model CPH6000

ProcessCalibrator Model CPH6000 Calibration technology ProcessCalibrator Model CPH6000 WIKA data sheet CT 15.01 Applications Calibration service companies/service industry Maintenance facilities Measurement and control laboratories Quality

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31 Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling

More information

Alicat Scientific Operating Bulletin. Alicat Scientific P and PC Series Pressure Gauge and Controller FLOW. Tare PSIG.

Alicat Scientific Operating Bulletin. Alicat Scientific P and PC Series Pressure Gauge and Controller FLOW. Tare PSIG. Alicat Scientific 14.70 Tare PSIG Main MODE FLOW Alicat Scientific P and PC Series Pressure Gauge and Controller Operating Bulletin Table of Contents Page Introduction 3 Installation 3 Pressure Gauges

More information

Fusion of electronic pressure sensor and analogue display.

Fusion of electronic pressure sensor and analogue display. Fusion of electronic pressure sensor and analogue display. Pressure sensors www.ifm.com/gb/pg fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0. Pressure Port With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 60 bar up to 00 bar Contacts, or independent PNP contacts, freely configurable

More information

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7 Applications With USB adapter and software Calibration service companies and service industry Quality assurance Recording and monitoring of pressure processes Measurement of pressure peaks Special features

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Carbon Monoxide Sensor - ModBus

Carbon Monoxide Sensor - ModBus Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read

More information

TPE 1464 Series Pressure Transducer

TPE 1464 Series Pressure Transducer TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm

More information

Manual Software R-LAS-LT-Scope (LT-Scope) V1.1

Manual Software R-LAS-LT-Scope (LT-Scope) V1.1 Manual Software R-LAS-LT-Scope (LT-Scope) V1.1 (PC software for Microsoft Windows 7, 8, 10) for Laser Reflection Sensor R-LAS-LT-110-HD2 This manual describes the installation process of the software for

More information

Precision hand-held pressure indicator Model CPH6400

Precision hand-held pressure indicator Model CPH6400 Calibration technology Precision hand-held pressure indicator Model CPH6400 WIKA data sheet CT 14.01 Applications Calibration service companies and service industry Measurement and control laboratories

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Reference Guide METTLER TOLEDO WMH Weighing Platforms

Reference Guide METTLER TOLEDO WMH Weighing Platforms Reference Guide METTLER TOLEDO Weighing Platforms Mettler-Toledo GmbH 2005 Doc.No. KA021, 42908713C Weighing Platforms Reference Guide Contents 1 Initial Setup... 4 1.1 Installation... 4 1.2 Electrical

More information

Huba Control. Pressure, vacuum and differential pressure transmitter. 0 3 / 5 / 10 / 30 / 50 mbar EDITION 12/2005

Huba Control. Pressure, vacuum and differential pressure transmitter. 0 3 / 5 / 10 / 30 / 50 mbar EDITION 12/2005 402 Pressure, vacuum and differential pressure transmitter 0 3 / 5 / 10 / 30 / 50 mbar EDITION 12/2005 Huba Control FOR FINE PRESSURE AND FLOW MEASUREMENT Technical overview The differential pressure transmitters

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual. 99 Washington Street Melrose, MA 0276 Fax 78-665-0780 TestEquipmentDepot.com DPI 820 Dual Input Thermometer User manual A B 0 0 0a 9a A 2 9 8 2 3 7 6 4 5 B 2 A2 6 5 4 3 22 7 8 2 9 20 Test Equipment Depot

More information

PS600 series For viscous media or contamination

PS600 series For viscous media or contamination PS600 series For viscous media or contamination The PS600 series operates with a frontflush mounted diaphragm seal. Pressure applied on the stainless steel diaphragm is transmitted via the filling medium

More information

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation d e v e l o p i n g s o l u t i o n s DE43 Data sheet Digital 2-channel transmitter for direct connection to bus-capable automation devices The bus-capable 2-channel transmitter is suitable for measuring

More information

Accessories. cab-5/eth-500. Design. Accessories RS232/Ethernet Adapter. Product name: cab-5/eth-500 incl. software SensorFinder

Accessories. cab-5/eth-500. Design. Accessories RS232/Ethernet Adapter. Product name: cab-5/eth-500 incl. software SensorFinder Accessories This network adapter converts standard RS232 signals of the sensor and provides an interface to a LAN network. The RS232 interface can be operated up to 115200 baud. - Auto-MDI-X able, supports

More information

Component identification

Component identification IO-ATC8 I/O Expansion Module 8 Analog/Thermocouple Inputs The IO-ATC8 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 inputs that

More information

Product Catalog. Represented by Norstat Inc. in North America

Product Catalog. Represented by Norstat Inc. in North America Product Catalog Represented by Norstat Inc. in North America About MP-Sensor MP-SENSOR a Technology Company located in Neuhausen in the south of Germany near Stuttgart is a company specializing in the

More information

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany LAN-Modem Operation Manual E121711217066 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright

More information

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939 Electronic pressure measurement Pressure transmitter for mobile hydraulic applications With output signals CNopen and J1939 Model MHC-1 WIK data sheet PE 81.49 pplications Construction machinery gricultural

More information

CHAPTER 1. Introduction Introduction 3

CHAPTER 1. Introduction Introduction 3 Technical & User Manual Weight Indicator: SMIT-3015 Manufactured By: Samyak Instrumentation Pvt.Ltd. F-4, Memnagar Complex, Opp.Petrol Pump, Memnagar Village, Ahmedabad, India-380052. Phone: +91-79-27495500/5600,

More information

IQ SENSOR NET MIQ/IF232

IQ SENSOR NET MIQ/IF232 Operating Manual IQ SENSOR NET Power! OK RS232 interface module for the IQ SENSOR NET ba76037e01 01/2012 Note For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI

More information

ProcessCalibrator Model CPH6000

ProcessCalibrator Model CPH6000 Calibration technology ProcessCalibrator Model CPH6000 WIKA data sheet CT 15.01 Applications Calibration service companies/service industry Maintenance facilities Measurement and control laboratories Quality

More information

QUICK START. ATEQ F620 Version 1.0. Reference: MR-28300A-U. (Photo no contractual)

QUICK START. ATEQ F620 Version 1.0. Reference: MR-28300A-U. (Photo no contractual) QUICK START ATEQ F620 Version 1.0 (Photo no contractual) Reference: MR-28300A-U REVISIONS OF THE ATEQ F620 USER MANUAL Due to continuing improvements, the information contained in this user manual, the

More information

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

Description. Type Product No. Measuring Range PMU-Type max. ambient temperature

Description. Type Product No. Measuring Range PMU-Type max. ambient temperature PM80VKS Duct sensor up to 0 C PM80VGS Room sensor up to 8 C PM-VS Sensors for humidity and temperature with RS232 signal level converter for digital transfer of the measurement values Rod and industrial

More information

Quickstart OPCom II. Read the safety instructions and operating instructions prior to commissioning!

Quickstart OPCom II. Read the safety instructions and operating instructions prior to commissioning! Quickstart OPCom II V1.06.13 Read the safety instructions and operating instructions prior to commissioning! ARGO-HYTOS GMBH Sensor and Measurement Division Industriestraße 9 76703 Kraichtal-Menzingen

More information

Precision pressure indicator 1- or 2-channel version Model CPG2500

Precision pressure indicator 1- or 2-channel version Model CPG2500 Calibration technology Precision pressure indicator 1- or 2-channel version Model CPG2500 WIKA data sheet CT 25.02 Applications Factory calibration laboratories Calibration service companies and service

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Pressure Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics and pneumatics Pumps and

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

MODEL : SLK-TL100 Receipt Printer User s Manual

MODEL : SLK-TL100 Receipt Printer User s Manual J. STEPHEN Lab., Ltd. 28-6, Gajangsaneopdong-ro, Osan-si, Gyeongi-do, 447-210, Korea TEL : +82-31-459-8200 FAX : +82-31-459-8880 www.miniprinter.com MODEL : SLK-TL100 Receipt Printer User s Manual TL100

More information

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03

More information

USER MANUAL MBAR EX By JETI model s.r.o

USER MANUAL MBAR EX By JETI model s.r.o USER MANUAL MBAR EX By JETI model s.r.o. 14. 11. 2014 CONTENTS 1. INTRODUCTION...3 2. MAIN FEATURES...3 3. PLACEMENT OF MBAR EX SENSOR...3 4. CONNECTING THE MBAR EX SENSOR...4 5. SETTING VIA JETIBOX...5

More information

Linear Position Transducer HLT 1000-R2

Linear Position Transducer HLT 1000-R2 7 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and

More information

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM) Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM) FIBER-OPTIC OXYGEN METER OEM-MODULE WITH UART-INTERFACE MANUAL Document Version 1.04 The Piccolo2-OEM is manufactured by PyroScience GmbH Hubertusstr.

More information

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00 BRODERSEN Message Displays/Operator Panels Message Display Operator Panel UCT-33/36 Industrial Terminal Manual 32.00 Brodersen Controls A/S. Betonvej 0. DK-4000 Roskilde. Denmark. Tel (+45) 46 74 00 00.

More information

RTD-500 Precision RTD Simulator. Operations Manual.

RTD-500 Precision RTD Simulator. Operations Manual. RTD-500 Precision RTD Simulator Operations Manual. Page 1 of 16 Table of Content. Table of Content....1 1 Scope...3 2 Package Content....3 3 Technical Data....3 4 Preparation for use....4 4.1 Switching

More information

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4 TRP-C08 USB to RS232/422/485 Isolated Converter User s Manual Printed Sep.2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

F3EM Measuring lightcurtain in robust aluminium housing

F3EM Measuring lightcurtain in robust aluminium housing Measuring lightcurtain in robust aluminium housing F3EM Measuring lightcurtain in robust aluminium housing The F3EM provides easy to install and set up height and profile measurement. The analog output

More information

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31 Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 for further approvals see page 8 Applications Food and beverage industry

More information

Features. IDS : Inclinometer Display System with RS232 Output

Features. IDS : Inclinometer Display System with RS232 Output Graphic Dual Axis Mode Dual Axis Mode Features Single Axis Mode Description Features The IDS is a high quality display system for use with many of our inclinometer sensors. It has a sturdy Aluminium housing

More information

SX100A. Features. Typical Applications. Description

SX100A. Features. Typical Applications. Description Datasheet -- Pressure Sensors: Measurement Type: Absolute; 0 psia to 100 psia, Unamplified, Representative photograph, actual product appearance may vary. Due to regional agency approval requirements,

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

Copyright Western Scale Co. Limited. All rights reserved.

Copyright Western Scale Co. Limited. All rights reserved. MAX DIGITAL WEIGHT INDICATOR OPERATION MANUAL SOFTWARE RELEASE 5.03, 04/2011 Copyright 2007-2011 Western Scale Co. Limited. All rights reserved. Published by: Western Scale Co. Limited. Information in

More information

Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version)

Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version) www.materm.si tel: 02 608 90 10 Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version) Calibration technology WIKA data sheet CT 12.01 Applications Calibration

More information

DIGITAL TRANSDUCER TESTER & PC-INTERFACE (AVA-03) 16-APR-2015 PAGE 1 OF 9 1. GENERAL

DIGITAL TRANSDUCER TESTER & PC-INTERFACE (AVA-03) 16-APR-2015 PAGE 1 OF 9 1. GENERAL PAGE 1 OF 9 1. GENERAL The Avanti I²C Transducer Tester and PC-Interface (AVA-03) is a standalone device for accessing pressure/temperature transducers, which are equipped with a two-wire serial I²C interface.

More information

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing Optical laser distance sensors Dimensioned drawing We reserve the right to make changes DS_ODSL96BMLTOFS12_en_50117984-01.fm en 03-2013/01 50117984-01 18-30 V DC 0.3 10m Measurement range up to 10000mm

More information

The ICP 300 is an ultra-compact, lightweight portable thermal printer with an easy-load paper feature.

The ICP 300 is an ultra-compact, lightweight portable thermal printer with an easy-load paper feature. THERMAL PRINTER Applications Datasheet Features Easy-Load paper feature RS232 Interface 10-35VDC Power Supply requirement High speed, high resolution printing capability Quiet, non-impact system Maintenance-free

More information

Communication protocol

Communication protocol Communication protocol Vacuum measurement and control unit for Compact Gauges RS232C interface Mnemonics BG 805 098 BE (9907) 1 Intended use This Communication protocol contains instructions for operating

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

SeriBox. antrax Datentechnik GmbH

SeriBox. antrax Datentechnik GmbH info@antrax.de SeriBox - Interface box with serial or USB interface - PC connection / Read IN and OUT signal information - 3 x INput (TTL level / floating contact) - 3 x OUTput (relay contact) Manual Firmware

More information

SX15GD2. Features. Typical Applications. Description

SX15GD2. Features. Typical Applications. Description Datasheet -- Pressure Sensors: Measurement Type: Gage; 0 psid to 15 psid, Unamplified, "D2" DIP Representative photograph, actual product appearance may vary. Due to regional agency approval requirements,

More information

Relative and differential pressure transmitter type 652

Relative and differential pressure transmitter type 652 Relative and differential pressure transmitter type 652 Pressure range 0... 50 1000 mbar Type 652 pressure transmitters are ideally suited to the continuous monitoring of liquid or level, (especially in

More information

Manual 601: : USB/RS232. Specifications. Contents. Options

Manual 601: : USB/RS232. Specifications. Contents. Options Page 1 ATE-601 601: : USB/RS232 I/O Controller - 8 Inputs, 4/8 Relays The ATE-500/600 series is a range of modular I/O controllers. It uses small standardized boards which allows you to configure the system

More information

Precision digital pressure gauge Model CPG1500

Precision digital pressure gauge Model CPG1500 Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration

More information

SX01DN. Features. Typical Applications. Description

SX01DN. Features. Typical Applications. Description Datasheet -- Pressure Sensors: Measurement Type: Differential, Gage; 0 psid to 1 psid, Unamplified, Ported "N" Package - Straight Port Representative photograph, actual product appearance may vary. Due

More information

Fiber optic Switch. eol 1x2 1x4 2x2. eol 1x8 1x12 1x16 OPERATION MANUAL

Fiber optic Switch. eol 1x2 1x4 2x2. eol 1x8 1x12 1x16 OPERATION MANUAL Fiber optic Switch eol 1x2 1x4 2x2 eol 1x8 1x12 1x16 OPERATION MANUAL CONTENTS Product Specification Features / Applications / Technology. 3 Optical Characteristics. 4 Electrical & Environmental Characteristics.

More information

PRODUCT INFORMATION. MPP5500 Series PANEL-MOUNT PRINTERS

PRODUCT INFORMATION. MPP5500 Series PANEL-MOUNT PRINTERS PRODUCT INFORMATION Series PANEL-MOUNT PRINTERS Applications Datasheet Features Easy load paper feature High speed, high resolution printing 5Vdc, 10-35Vdc or low power Quiet, non-impact system Maintenance-free

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B... Technical Data *

Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B... Technical Data * Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B... 1... 5 The AQCS is used in conjunction with quartz cavity pressure sensors for measuring cavity pressure on injection molding machines,

More information

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold L-LAS Series L-LAS-LT-85-RA-CL (Reduced Amplification) - Operates in an angle of total reflection - Suitable für high-glossy objects (e.g. glass) - Line laser

More information

Mesa Met Lab Series Bi-Directional Communications Protocol

Mesa Met Lab Series Bi-Directional Communications Protocol Mesa Met Lab Series Bi-Directional Communications Protocol To enable Mesa customers to integrate their Met Lab Series primary piston provers with their unique applications, our Met Lab systems come standard

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION

MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION 4-20mA Output The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature

More information

ZM24x Quick-Connect Industrial Modem. User s Manual

ZM24x Quick-Connect Industrial Modem. User s Manual ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of

More information

COMMUNICATION WITH OTHER SERIAL DEVICES

COMMUNICATION WITH OTHER SERIAL DEVICES Application Bulletin: #169 Date: November 2009 BLACKBELT COMMUNICATIONS INTERFACE The setup and operation of the Sentinel BLACKBELT communication options are explained in Error! Reference source not found.,

More information

LFC Liquid Flow Controller

LFC Liquid Flow Controller LFC Liquid Flow Controller Type 879 can be combined with High dynamic control through fast flow measurement Applicable for liquid dosing up to 600 ml/min (6 l/h) No moving parts in medium Fieldbus optional

More information

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063 Mechatronic pressure measurement Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063 WIKA data sheet PV 12.03 for further approvals see page

More information

MEDIUM-PRESSURE-CALIBRATOR

MEDIUM-PRESSURE-CALIBRATOR MEDIUM-PRESSURE-CALIBRATOR STANDARD- AND FULL-VERSION RANGE SERIAL-NR. PROGRAM-VERSION DATE KELLER INCLUDED IN DELIVERY: MEDIUM PRESSURE CALIBRATOR STANDARD-VERSION INCLUDED IN DELIVERY: MEDIUM PRESSURE

More information

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550 Data sheet Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550 The P500 / P507 / P550 utilizes the thin film strain gauge sensing technology, incorporating an hermetically

More information

PCD DIGITAL Differential pressure probe

PCD DIGITAL Differential pressure probe Differential pressure probe 2016 ROTRONIC AG Bassersdorf Switzerland Contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Variants... 4 3 General information... 6 3.1 Power supply...

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mh O up to 0... 50 mh O Output signals -wire: 4... 0 ma -wire: 0...

More information

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric

More information

Thermoelectric Cooler Controller TED1000

Thermoelectric Cooler Controller TED1000 Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...

More information

Installation and operation manual ReciFlow Gas

Installation and operation manual ReciFlow Gas Installation and operation manual ReciFlow Gas 1 1. Measurement principle... 3 2. Installation... 5 3. Operation... 7 4. Electrical interfaces... 11 5. Communication protocol... 14 6. Software update and

More information

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X R Calibration Technology High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X WIKA Data Sheet CT 28.01 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture

More information

MODEL : SLK-T12EB Receipt Printer User s Manual

MODEL : SLK-T12EB Receipt Printer User s Manual J. STEPHEN Lab., Ltd. 28-6, Gajangsaneopdong-ro, Osan-si, Gyeonggi-do, 447-210 Republic of Korea TEL : +82-31-8077-5000 FAX : +82-31-459-8880 www.miniprinter.com MODEL : SLK-T12EB Receipt Printer User

More information