Syncrolite ArenaColor User Guide
|
|
- Berniece Hopkins
- 5 years ago
- Views:
Transcription
1 Syncrolite ArenaColor User Guide Syncrolite, LP 2025 Royal Lane, Suite 370 Dallas, TX fax 1
2 Tapping the ballast WARNING: Power must be turned off before tapping the ballast. This operation should only be performed by qualified personnel. Hazardous voltage is present and extreme caution should be exercised. Set the ballast by moving the orange wire to the appropriate terminal. In a typical European (50 hz) power system, measure the line to line voltage and choose the tap corresponding to the voltage closest to the measured value. 2 = 380 v 3 = 400 v 4 = 415 v American (60 hz) power system 2 = 420 v 3 = 450 v 4 = 480 v Metering power WARNING: This operation should only be performed by qualified personnel. Hazardous voltage is present and extreme caution should be exercised. Lamp power is measured with power applied and the lamp operating for at least 20 minutes. The ArenaVision lamp operates from AC and incorporates a magnetic ballast. A true RMS power meter must be used, monitoring the voltage and current at the same time. The meter needed for checking watts on an Arena light is a True RMS AC Power Meter set on watts. See power meter spec sheet. Please NOTE: The method for metering a Xenon lamp will not give a correct measurement for ArenaVision. Clamp the black wire connected to the #2 position on the relay. Insert probes into the black and white wire that connects to the lamp as shown below. 2
3 3
4 Philips ArenaVision and GE 2000 sports fixtures do not support hot re-strike. Should power supply failure occur the lamphead should be cooled completely before re-strike, usually about minutes. Failure to allow for cooling before re-strike will result in damage to igniters or the unit. Terminators This unit is equipped with DMX input and output connectors to facilitate a daisy chain connection of multiple units. A terminating plug must be installed in the DMX output connector at the end of the chain regardless of how many units are connected. Assigning the DMX start address DMX start address is assigned using the three dip switches inside the ballast. See photo below. 4
5 DMX Info DMX Profile: 5 channels 1 Douser 2 Color 1 3 Command Word 4 Command Execute 5 Color 2 If used (not currently being used) Syncrolite Arena Color Commands (0-255 Decimal Values) To Strike Lamp Step One: Set Channel 3 (Command Word) to 43 Step Two: Set Channel 4 (Command Execute) to 86 Step Three: Set Channel 4 (Command Execute) to 171 To Kill Lamp Step One: Set Channel 3 (Command Word) to 85 Step Two: Set Channel 4 (Command Execute) 86 Step Three: Set Channel 4 (Command Execute) 171 To Reset Fixture Step One: Set Channel 3 (Command Word) to 169 Step Two: Set Channel 4 (Command Execute) to 86 Step Three: Set Channel 4 (Command Execute) to 171 5
6 Basic Setup DMX Cables All Syncrolite products use DMX protocol. We recommend a maximum DMX cable length of 2000, though the system will operate up to 1 mile from the DMX source with quality cable and a DMX splitter. AC Power Cables Syncrolite power distros accept a 3 pole 4 wire European twist lock connector. Power Cables Lamp power is provided between the ballast and lamphead via 12/3 600 v cable with 3 pin 35A connector. 6
7 Changing a Lamp WARNING: Power must be turned off before changing a lamp. This operation should only be performed by qualified personnel. Hazardous voltage is present and extreme caution should be exercised. Step 1 Un-latch retaining clips and pull down back cover. Step 2 Un-hook the spring clip that holds the lamp to the socket. 7
8 Step 3 Pull the lamp from the lamp socket. Step 4 Install the new lamp taking care not to touch the glass envelope. Use the enclosed alcohol wipe to wipe off the envelope of the new lamp. Re-hook the spring clip and close the back cover. 8
9 Accessing and Removing Cartridges WARNING: Power should be turned off before accessing cartridges. Damage will result in the electronics if you remove a cartridge while power is on. This operation should only be performed by qualified personnel. Hazardous voltage is present and extreme caution should be exercised. Step 1 Un-latch two latches to remove the top cover and filter. Step 2 Release the spring retaining clip by pressing it. Step 3 Pull the cartridge out by its handle. 9
10 10
11 Removing or Installing a Scroll **See prior section on how to access and remove the scroller cartridge. Step 1 Roll all of the frames to the spring roller side (closest to the motor). Step 2 Remove the tape securing the end of the scroll to the fixed roller tube. Step 3 Roll up the scroll. You should end up with the scroll tag on the outside as shown below. 11
12 Step 4 Using three pieces of 3 long gel tape secure the tag side of the scroll to the spring roller tube (side with motor). Align the scroll with the 2 screws on the roller tube. Roll the scroll onto the spring roller keeping the scroll taught with tension. 12
13 Step 5 Rotate the fixed roller tube four complete revolutions to tension the spring. Step 6 Using three pieces of 3 long gel tape, secure the end of the scroll to the fixed roller tube. 13
14 400A AC/DC Watt Clamp-on Measures Watts, Current, and Voltage With AC/DC True Power measurements to 240kW Features: True RMS AC Voltage and Current 0.9" (23mm) jaw opening Large 4000 count LCD display Fast 40 segment analog bargraph Data Hold, Max/Min recall, Auto Zero (DC current), plus low battery indication Frequency to 10kHz Auto power off Complete with test leads, 2 AA batteries, and carrying case Specifications: Range Resolution Accuracy ±(%rdg+digits) Input Signal Range AC Power 40kW 10W ±(1.5% + 3d)@50/60Hz 0-250V, 0-400A, PF kW 100W ±(1.5% + 3d)@50/60Hz 0-600V, 0-400A, PF 0-1 DC Power 40kW 10W ±(1.5% + 3d) 0-250V, 0-400A 240kW 100W ±(1.5% + 3d) 0-600V, 0-400A AC Current 400A 0.1A ±(1.5% + 3d)@50/60Hz Overload protection: 600A AC (AC frequency range 40Hz-1kHz) DC Current 400A 0.1A ±(1.5% + 3d) Overload protection: 600A DC AC Voltage 600V 1V ±(1.5% + 2d)@50/60Hz Overload protection: 800V AC DC Voltage 400V 0.1V ±(1.0% + 2d) Overload protection: 800V DC Frequency 10kHz Hz ±(0.8% + 2d) Overload protection: 600V AC Dimensions 7.2 x 2.5 x 1.4" (183 x 64 x 36mm) Weight 6.7oz (190g including batteries) Ordering Information: A AC/DC Watt Clamp-on NIST with Calibration Traceable to NIST Specifications subject to change without notice. 7/27/10 - R1 Copyright 2010 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form.
DC / AC True RMS Watt Clamp DMM
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 380940 Product Page DC / AC True RMS Watt Clamp DMM 10W or 100mA
More informationINSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage
INSTRUCTION MANUAL Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter True RMS AC Current and Voltage Measure low current with high resolution to 0.1mA AC and 1mA DC Auto Power Off One touch DCA zero
More informationR5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com
Model R5050 TRMS AC/DC Clamp Meter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-6 Instrument Description...7-8 Measurement Procedures...9-12 Battery
More informationATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual
ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual EN 61010-2-032 CAT II 600V, CAT III 300V Pollution Degree 2 SYMBOLS showed on the clamp meter or in this manual: Caution, risk of danger. Refer to accompanying
More informationUser's Guide. Model Laser Photo Tachometer
User's Guide Model 461920 Laser Photo Tachometer Introduction Congratulations on your purchase of Extech's Mini Laser Photo Tachometer, Model 461920. This Tachometer provides non-contact RPM and Revolution
More informationUser's Guide. Extech AM A AC Analog Clamp Meter
User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.
More informationUser Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at
User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-773 61-775 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationUser's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction
User's Guide Power Analyzer Model 380801 Power Analyzer Datalogger Model 380803 Introduction Congratulations on your purchase of the Extech 380801 or 380803 Power Analyzer Datalogger. This device offers
More informationUser s Guide. 600A AC Clamp Meter. Model 38387
User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationUser s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389
User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further
More informationI. PANEL DESCRIPTION... 1
Table of Contents I. PANEL DESCRIPTION... 1 II. OPERATING INSTRUCTION... 7 1. MA OUTPUT... 7 1A. GENERAL OPERATION 4-20MA... 7 1B. SELECT 0-20MA OR 0-24MA... 8 1C. ENTER A VALUE LESS THAN 1... 9 2. % (PERCENTAGE)
More informationVibration Meter and Laser Combination Tachometer
User's Guide Vibration Meter and Laser Combination Tachometer Model 461880 Introduction Congratulations on your purchase of the Extech 461880 Vibration Meter and Combination Laser Tachometer. The 461880
More informationVBAR 270. User Manual. Version 1.2
VBAR 270 User Manual Version 1.2 VBAR 270 User Manual Page 1of 19 Introduction Thank you for purchasing VBAR 270. VBAR 270 is a LED light fixture for professional use. Using the RGB color mixing technology
More informationUser's Guide. Vibration Meter and Laser Combination Tachometer Model
User's Guide Vibration Meter and Laser Combination Tachometer Model 461880 Introduction Congratulations on your purchase of the Extech 461880 Vibration Meter and Combination Laser Tachometer. The 461880
More informationPower Analyzer Datalogger Model
User's Guide Power Analyzer Model 380801 Power Analyzer Datalogger Model 380803 Extech 380803 Appliance Tester/Power Analyzer Extech 380803 True RMS Power Analyzer Data Logger Extech 380803-NIST True RMS
More informationScroller Operating Manual
Other products available from Apollo: Stainless Steel Gobos Aluminum Gobos Glass Gobos Dichroic Glass Filters Gel Filters Gel Frames Gel Cabinets Donuts Pattern Holders Stage Foil Intelligent Lighting
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation
More informationModel A Mini AC/DC Clamp Meter. User's Guide
Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,
More informationMultifunction Calibrator
Multifunction Calibrator Model CL TC - - - C V _ TECPEL CO., LTD. Features:. - (KΩ load, V Loop Supply). -.,-.V, -.V. K, J, E, T Thermocouple ( C and ). Frequency -.. Basic Accuracy. Easy Key-pad Operation.
More informationS-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter
S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter
More informationOperation Manual. 4Bank DMX
Operation Manual 4Bank DMX Part No. 3100070 Rev C 08-29-2017 Systems CFX-484 4ft 4Bank Fixture w/ Louver/HP, 90 CFX-244 2ft 4Bank Fixture w/ Louver/HP, 90 MTP-KW41 Kino 41K Mount Wing w/ 3/8 Pin (10mm)
More informationUser's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented
User's Guide 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your
More informationDigital Clamp Meter User Manual
Compact AC, AC/DC Digital Clamp Meter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents 1.Safety... 3 2.Safety Notes... 3 3.Warnings... 3 4.Cautions...
More informationWhisper Color Scrollers
Whisper Color Scrollers Copyright 2007 Compulite Systems (2000) Ltd. All rights reserved. This documentation is delivered subject to the following conditions and restrictions: This document is protected
More informationUser's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter
User's Guide 800 Amp Clamp Meters EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter Introduction Congratulations on your purchase of the EX710, EX720, or EX730 Clamp DMM.
More informationUser's Guide. MiniTec TM Series Model MN25 MultiMeter
User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More informationRemoval and Installation8
8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever
More informationUser Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP
0 User Guide ExStik TM Model RE300 Waterproof ORP Meter Patent Pending 500 MV 1000 TM RE300 ORP ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE button 4. CAL
More informationUser Guide. Moisture Meter. Model MO250
User Guide Moisture Meter Model MO250 Introduction Congratulations on your purchase of the Extech MO250 Moisture Meter. The MO250 detects moisture in wood and other building materials such as brick, wall
More informationWHISPER Color Scroller TYPE 1kW D
WHISPER Color Scroller TYPE 1kW D Illustration: Whisper 1kW D February 2000 Table of Contents General Description... 1 Features... 1 Technical Description... 2 MX Split Box DMX Power Suply Unit... 3 Cable...
More informationExtech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide
Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer User's Guide Introduction Congratulations on your purchase of the Extech EX820 True RMS 1000A Clamp Meter. This meter measures AC/DC Voltage,
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationUSER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160
USER GUIDE Dual Input True RMS AC Voltage/Current Datalogger Model DL160 Introduction Congratulations on your purchase of this Dual Input Voltage / Current datalogger. With this meter, you can monitor
More informationModel: Pro93 TRUE RMS LEAKAGE CURRENT TESTER
Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER CONTENTS TITLE PAGE I. Safety Information.......1 Environmental Conditions... 1 Explanation of Symbols..... 1 II. Specification..... 2 General Specification...
More informationMANUAL PCE-123
www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk
More informationMini Digital Multimeter
User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers
More informationArcControl Version: 1.0
ArcControl 1024 Version: 1.0 User Guide - Getting Started This manual is in three sections: 1. Getting Started: Specifications, installation, and using the controls (p. 2) 2. The Quick-Setup Assistant
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More informationUser Manual VX4234 Digital Multimeter Module
User Manual VX4234 Digital Multimeter Module 070-9139-02 This document applies for firmware version 1.00 and above. General Safety Summary Review the following safety precautions to avoid injury and
More informationUSER GUIDE. AC/DC Magnetic Meter. Model MF100
USER GUIDE AC/DC Magnetic Meter Model MF1 Introduction Thank you for selecting the Extech Instruments Model MF1. This device is shipped fully tested and calibrated and, with proper use, will provide years
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-609 The Service Information provides the following information: Precautions
More informationMegatouch FORCE Monitor Chassis Board Replacement
Megatouch FORCE Monitor Chassis Board Replacement Visit the Merit Industries, Inc. Web site http://www.meritind.com merit industries, inc. PM0337-01 Rev C Table of Contents FORCE Classic Monitor Chassis
More informationCobra Dimmer Master DMX Controller User Manual
Cobra Dimmer Master DMX Controller User Manual User Manual Dimmer Master Dear Customer, Thank you for purchasing the Dimmer Master DMX controller. With decades of experience in design and production, we
More informationETHOS Auto Ranging Digital Multimeter
ETHOS 5020 Auto Ranging Digital Multimeter 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this Meter. Double
More informationTrue RMS AC Voltage/Current Datalogger
User's Guide True RMS AC Voltage/Current Datalogger Model DL150 Introduction Congratulations on your purchase of this Voltage or Current datalogger. With this meter, you can monitor and log data over long
More informationOperation Manual. Imara S100 & S60 DMX. Imara S100 DMX Yoke Mount. Imara S100 DMX Pole-Op
Operation Manual Imara S100 & S60 DMX Imara S100 DMX Yoke Mount Imara S100 DMX Pole-Op Part No. 3100083 Rev A 03-02-2015 Imara DMX Yoke Mount Imara Fixtures IMR-S100-120U Imara S100 DMX Yoke Mount, Univ
More informationUser Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer
User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech EX820
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More informationШирокий ассортимент оборудования ACME на User Guide. Professional Entertainment Technology
Широкий ассортимент оборудования ACME на www.maxlight.ru User Guide Professional Entertainment Technology EC Declaration of Conformity We declare that our products (lighting equipments) comply with the
More informationCM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL
CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationLED PAR56 Order Code: P56-151
LED PAR56 Order Code: P56-151 www.cobrainternational.com User Manual COBRA P56-151 Dear Customer, Thank you for purchasing the COBRA P56-151. Cobra is one of the leading manufacturers of professional equipment
More informationMONARCH 9416 XL QUICK REFERENCE
MONARCH 9416 XL QUICK REFERENCE This Quick Reference contains ribbon loading, supply loading, and general care, maintenance, and troubleshooting procedures for the 9416 XL Thermal Direct and 9416 XL Thermal
More informationThis document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.
SM5/Gauntlet Stepmill Power Trace Applies to: SM5 (150005) + Gauntlet (150015) This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills. Latest Rev. Warning: the
More informationRTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version
RTD Process Calibrator User s MANUAL Safety Information RTD Process Calibrator User s Manual To avoid possible electric shock or personal injury: Never apply more than 30V between any two jacks, or between
More informationModel R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com
Model R5005 True RMS Industrial Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 4 Features... 5 Specifications...5-6 Instrument Description...7-8 Operating Instructions...9-13
More informationWe take care of it. Mobile Power Quality Analyzers. PQ-Box 100/150/200. Accessories
We take care of it. Mobile Power Quality Analyzers PQ-Box 100/150/200 Accessories Rogowski coil set Current range: 1 A to 3000 A RMS; Set of 4 pieces Accuracy: 1%; Size: 61 cm (24 ); Diameter = 194 mm
More informationCompact, Low Profile High Rendering, 100% Diffusion
SURFACE MT SERIES PRELIMINARY SPECIFICATION, SUBJECT TO CHANGE WITHOUT NOTICE MT Series Compact, Low Profile High Rendering, 100% Diffusion Trimless, No Visible Hardware Trimless appearance for recessed
More informationOperating instructions only for authorized, skilled electricians with EIB training
73-1 - 6122 25054 ABB i-bus EIB 1-fold Switching Actuator/Sensor 6110 U-500 GJB 000 6151 A0162 flush-mounted Operating instructions only for authorized, skilled electricians with EIB training Contents
More information1000A 3-Phase Power Analyzer/Datalogger
User Guide 1000A 3-Phase Power Analyzer/Datalogger Model 382090 (60Hz) Model 382091 (50Hz) Introduction Congratulations on your purchase of the Extech 382090/382091 1000A 3-Phase Power Analyzer Datalogger.
More informationAutoranging True RMS Multimeter User Manual
Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.
More informationAccessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200
Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 05-2017 Accessories for PQ-Box 100 & 150 & 200 Page 1 Rogowski coil set CAT IV 600V Current range: 1A to 3000A RMS; Accuracy: 1%
More informationUser's Guide. Phase Sequence and Motor Rotation Tester Model
User's Guide Phase Sequence and Motor Rotation Tester Model 480403 Introduction Congratulations on your purchase of the Extech Model 408403 Motor and Phase Rotation Indicator. This handheld instrument
More informationUSER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at
USER MANUAL Heavy Duty Manifold Pressure Gauge Model HD780 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech Instruments Heavy
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity
More informationUser's Guide. Model (60Hz) Model (50Hz) 1000A 3-Phase Power Analyzer/Datalogger NO.
User's Guide 1000A 3-Phase Power Analyzer/Datalogger Model 382090 (60Hz) Model 382091 (50Hz) P Q S NO. U12 Y-M U23 D-h U3 m-s 1 2 c I4 3 4 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument
More informationACT-1B Series Panel Tachometer
MONARCH INSTRUMENT Instruction Manual ACT-1B Series Panel Tachometer Printed in the U.S.A. Copyright 2009 Monarch Instrument, all rights reserved 1071-4843-111R 0909 15 Columbia Drive Amherst, NH 03031
More informationUser s Manual. Models Digital Force Gauge. Additional User Manual Translations available at
User s Manual Models 475055 Digital Force Gauge Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of Extech s Model 475055 Digital Force Gauge
More informationInstalling 6 Indexer: PRS Standard Tools
888-680-4466 ShopBotTools.com Installing 6 Indexer: PRS Standard Tools Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Overview...5 Installing the
More informationHigh Precision Quad Output DC Power Supply
User's Guide High Precision Quad Output DC Power Supply Model 382270 Introduction Thank you for selecting the Extech Model 382270. This device is shipped fully tested and calibrated and, with proper use,
More informationLIGHTING S. Table of Contents. Lighting Kimball Surfaces & Storage. Price List Effective Dates: Pricing Revision
LIGHTING S Table of Contents Price List Effective Dates: Pricing 07.02.18 Revision 06.15.18 See page page 7.2 Planning page 7.2 Pricing page 7.3 page 7.4 Planning page 7.4 Pricing page 7.5 for Use in Chicago
More informationIntegrating Sound Level Datalogger Model
User's Guide Integrating Sound Level Datalogger Model 407780 Introduction Congratulations on your purchase of the Extech 407780 Integrating Sound Level Meter. The 407780 with programmable integrating time
More informationBENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL
BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL SK-4033 / SK-4035 Thank you for purchasing KAISE MODEL SK-4033/4035 BENCH-TOP DIGITAL MULTIMETERS. To obtain the maximum performance of this instrument,
More informationContents. Please read and remember the following warnings before using the RELAYplate:
Contents 1 Warnings o 1.1 What is a Relay? o 1.2 Basic Features of the RELAYplate o 1.3 Attaching a Load to the RELAYplate o 1.4 The RELAYplate Command Set 1.4.1 RELAY Control Functions 1.4.2 LED Control
More informationRobocolor II System. users guide
Robocolor II System users guide CONTENTS INTRODUCTION... 3 INSTALLING THE ROBOCOLOR II SYSTEM... 3 OPERATING WITHOUT A LIGHTING CONTROLLER - STAND ALONE... 4 OPERATING STAND ALONE IN MASTER/SLAVE MODE...
More informationSP-1500 DMX MK II Strobe
SP-1500 DMX MK II Strobe Operation Manual A.D.J. Supply Europe B.V. Junostraat 2 6468 EW Kerkrade The Netherlands www.americandj.eu 10/2011 A.D.J. Supply Europe B.V. www.americandj.eu SP-1500 DMX MKII
More informationInk-Dot Series II Driver
Instruction Sheet P/N 766B Ink-Dot Series II Driver Introduction See Figure. Ink-Dot Series II controllers can have from one to three driver modules. Any existing controller can easily be retrofit with
More informationUser's Guide. Digital Multimeter. Model MN42
User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and
More informationTrue RMS Multimeter with IR Thermometer
User Guide True RMS Multimeter with IR Thermometer Extech EX210T Introduction Thank you for selecting the Extech EX210T True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current,
More informationUSER GUIDE. Differential Thermometer Datalogger. Model HD200
USER GUIDE Differential Thermometer Datalogger Model HD200 Introduction Congratulations on your purchase of the Extech HD200 Differential Thermometer Datalogger. The HD200 supports differential temperature
More informationVEUE WIRE GUIDE INSTALLATION MANUAL. June 2016
VEUE WIRE GUIDE INSTALLATION MANUAL June 2016 CONTENTS June 2016 This manual is to be read in conjunction with the Product Specifications & Assembly manual SECTION NO. DESCRIPTION PAGE NO. SECTION 1 ITEMS
More informationAccessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 & 300
Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 & 300 Jun-18 Accessories for PQ-Box 100 & 150 & 200 & 300 Page 1 Rogowski coil set CAT IV 600V Current range: 1A to 3000A RMS,
More information4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:
TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Configuration 6. DMX512 Connections 7. How to Set the Unit 8. Troubleshooting
More informationModel R5010. TRMS Digital Multimeter. Instruction Manual
INSTRUMENTS Model R5010 TRMS Digital Multimeter Instruction Manual Table of Contents Safety...3-4 IEC1010 Overvoltage Installation Category... 3 Warnings... 4 Features... 5 Specifications...5-8 Instrument
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-796 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationHeavy Duty Vibration Meter
USER MANUAL Heavy Duty Vibration Meter Model 407860 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech 407860 Vibration Meter. The
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series
More information5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter
5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 SST7000 SST7100 Speed Switch / Transmitter Installation and Operation Manual Rev. C P/N145F-13112 PCO 00009270
More informationVibration Meter SD Card real-time datalogger
User's Guide Vibration Meter SD Card real-time datalogger Model SDL800 Introduction Congratulations on your purchase of the Extech SDL800 Vibration Meter. This meter displays and stores vibration readings
More informationAutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82175 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationdynamic white par manual
dynamic white par manual V2.0 AUGUST 2017 table of CONTENTS Dimensions 1 Safety information 2 Fixture overview 4 Introduction 5 AC power 5 Power voltage 5 Power cables 6 Relaying power to other devices
More informationHeat Stress WBGT Meter
USER MANUAL Heat Stress WBGT Meter Model HT200 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model HT200 Heat Stress WBGT Meter.
More informationUser's Guide. Model W 3-in-1 Switching DC Power Supply
User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges
More informationDEB 1.2k/2.5k. Electronic Flicker Free Ballast MOD INSTRUCTION AND MAINTENANCE MANUAL
Pag. # 1 2 DEB 1.2k/2.5k Electronic Flicker Free Ballast MOD. 2525.210 INSTRUCTION AND MAINTENANCE MANUAL Pag. # 2 INDEX Section 1 - DESCRIPTION Section 2 - OPERATION & ROUTINE MAINTENANCE Section 3 DISPLAY
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationUser's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer
User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer Patented Introduction Congratulations on your purchase of the Extech EX840 CAT IV True RMS 1000A Clamp Meter. This meter measures
More informationModel. True RMSmA Clamp Meter. Instruction Manual
R5015 Model True RMSmA Clamp Meter Instruction Manual info@reed-direct.com REED-Direct.com 1.888.610.7664 Table of Contents Safety...2 Features...3 Specifications... 3-5 Electrical Symbols...6 Product
More informationHeavy Duty Hot Wire CFM Thermo-Anemometer
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extecch 407119 Product Page Heavy Duty Hot Wire CFM Thermo-Anemometer
More information50 Amp AC/DC Current Probe PA-655 INSTRUCTION MANUAL 安培交流 / 直流電流探測鉗. DC 500KHz. 5mA 50A.
50 Amp AC/DC Current Probe 安培交流 / 直流電流探測鉗 PA-655 DC 500KHz. 5mA 50A INSTRUCTION MANUAL TABLE OF CONTENTS General Safety Instructions------------------------------------------------- 4 Safety Terms and
More informationRS Stock No Instruction Manual RS Input Data Logging Thermometer
RS Stock No. 730-0458 Instruction Manual RS-1384 4 Input Data Logging Thermometer EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION FEATURE... 1 2. SPECIFICATIONS... 2
More information