1 FUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL Trak Engineering, Inc Crescent Drive Tallahassee, FL Phone:(850) FAX:(850) Web Site:

2 IMPORTANT The SentryGOLD and associated equipment will be installed in close proximity to combustible fuel dispensers. For the safety of all concerned, it is essential that you read and understand the instructions in this manual before proceeding. ****** CAUTION ****** TURN OFF ALL POWER TO THE ISLAND BEFORE BEGINNING INSTALLATION. THE SENTRYGOLD SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NFPA NO. 70), THE AUTOMOTIVE AND MARINE SERVICE STATION CODE (NFPA NO. 30A) AND LOCAL ORDINANCES. DO NOT INSTALL THE SENTRYGOLD SYSTEM IN A LOCATION THAT DOES NOT MEET THE REQUIRED STANDARDS AS LISTED ABOVE. QUALIFIED LICENSED ELECTRICIANS ARE REQUIRED TO PERFORM ANY MODIFICATIONS OR ALTERATIONS TO THE ELECTRICAL CIRCUITS AT ANY INSTALLATION SITE ALL PARTS USED TO INSTALL THE SENTRYGOLD SYSTEM INSIDE A DISPENSER THAT ARE NOT PART OF THE INSTALLATION PACKAGE, SHALL BE SUITABLE FOR USE IN CLASS 1, GROUP D HAZARDOUS LOCATIONS. ALL INSTALLATIONS SHALL ALSO COMPLY WITH OSHA SAFETY STANDARDS. FAILURE TO COMPLY WITH THE LISTED CAUTIONS MAY RESULT IN SERIOUS PERSONAL INJURIES, PROPERTY LOSS AND/OR EQUIPMENT DAMAGE.

3 TABLE OF CONTENTS SECTION 1.0 OVERVIEW Product Description Installation Overview Site Criteria Pre-Installation Instructions. 4 SECTION 2.0 SENTRY MOUNTING Location Sentry Mounting. 6 SECTION 3.0 MOTHER BOARD INSTALLATION. 8 SECTION 4.0 FIELD WIRING Overview Connecting Power Control Card Installation Pulser Card Installation Communication Card and External Comm. Cable Install. 19 SECTION 5.0 COMPACT INSTALLATION Overview Electrical Connections Inserting the Compact into the Housing 22

4 Section 1.0 Overview The object of this document is to provide a standard for the installation of the TRAK SentryGOLD Fuel Management System (FMS). Installation of this system shall ONLY be performed by qualified service personnel. 1.1 Product Description The SentryGOLD System installation consists of three primary groups: The SentryGOLD Pedestal Dispenser Interface Communication Interface 1.2 Installation Overview The instructions contained in this manual are intended as guidelines. They will not describe all possible variations that may occur. If the person installing the SentryGOLD is not thoroughly knowledgeable in all aspects of this type installation, it is strongly recommended that assistance be requested from Trak Customer Support at (850) before proceeding. The installer will mount the SentryGOLD on, or near, fuel dispensers, connect power and control lines from the SentryGOLD mother board to the dispensers and mount and test the communication links. One SentryGOLD mother board will control up to 5 high power devices such as a pump motor, or 10 low power devices such as a dispenser solenoid valve or 30 fiber optically controlled hoses. 1.3 Site Criteria The Sentry will control virtually any dispenser on any island configuration. It may be placed in almost any environment. However, there are several environmental restrictions that must be followed for both safety and functionality: DO NOT locate the Sentry where the temperature is consistently above +130 F or below -40 F DO NOT locate the Sentry where it will put the user at risk from the local traffic. DO NOT locate the Sentry within 18 inches of a dispenser or within 10 feet of a natural gas dispenser. 3

5 1.4 Pre-Installation Instructions The SentryGOLD Fuel Management System will accommodate either single or dual hose dispensers. It may be installed to control either a remote or a selfcontained dispenser. Before installation, it must be determined that there is sufficient space in the dispenser junction box to install the required equipment. The SentryGOLD can control dispensers either with fiber optic controls or with direct hard wire connections. If Connecting with Fiber Optics: There must be sufficient space for the Pump Control Module to be installed without interfering with the operation of the dispenser or the access required for maintenance or service. A. Each dispenser junction box must have one available opening, which can be used to connect the PCM. B. Open the junction box. Determine if there is sufficient space to safely make the additional connections that will be required. If the box appears to be full, have an electrician trim the existing wiring to provide the necessary space. The volume of the junction box, in cubic inches, is usually stamped on the inside. You will need approximately 10 cubic inches. If not, you can measure the length, width and depth of the box to calculate the available space. Estimate the amount of available space currently taken up by the wires in the box. This will give you an approximate value for the remaining space. For example, if a junction box that is 30 cubic inches in size is one third full, there will be 20 cubic inches remaining. C. If the dispenser already has a pulser unit attached, it will have to be removed. ONLY TRAK APPROVED PULSERS AND PULSER POWER UNITS MAY BE USED AND ONLY CONNECTED TO THE VEEDERROOT MECHANICAL REGISTERS. Check to make sure that the pulser is compatible with the register and dispenser and that its wires can be safely routed to the bottom of the dispenser. The PCM can be used if, and only if all the above conditions are satisfied. If for any reason these criteria cannot be met, contact TRAK for alternate methods of installation. 4

6 If Connecting with Hard Wire: If controling the dispener with hard wire, conduit will need to be run from each dispenser to the Fuel Sentry housing. This may already exist. If not, it will have to be run. It can be run above ground on top of the fuel island as long as it does not present a trip hazard. The use of hard wire will also require separate conduit lines for power and pulser circuits. Section 2.0 Sentry Mounting The first part of the installation shall be the Fuel Sentry housing. As mentioned earlier, there are many different fuel island configurations. The following example should be used as a guideline and adapted to your specific needs. The Sentry can be supplied with a riser. It is designed to be mounted at the bottom of the Sentry housing and is made from a durable plastic but also allows any conduit to be easily run through it. It also is designed to allow the Sentry to be mounted higher when required. If the users will be standing on the same level as the Sentry, the riser should be used so the Sentry can be at optimum height. If the Sentry is mounted on a raised fuel island, the Sentry housing can be mounted directly to the island surface without the riser. 2.1 Location The Sentry, as shown below, is designed to be mounted within a few feet of the dispenser. As a minimum, it must be mounted no closer than 18 inches of any nozzle opening. Site conditions permitting; place the Sentry 2 to 3 feet from the dispenser. 5

7 SENTRY RISER FUEL ISLAND Conduit to dispenser The picture above shows the Sentry housing ready to be placed on the riser. It has a piece of conduit run from the housing out through the riser over to the dispenser. Multiple conduits are required in most installations and are not represented in this example. Bear in mind that the Sentry may also have several Fiber Optic (FO) cables running from the Sentry housing to the dispensers if fiber optic controls are utilized. In many cases, existing conduit may already be installed. The Sentry may be bolted down over the existing conduit. Remember that power must be delivered to the Sentry and control cables must run from the Sentry to the dispenser. Exactly how this is accomplished is not critical, but, must comply with all required codes. 2.2 Sentry Mounting Using the template located in the back of this manual, layout the proper bolt pattern for the Sentry. As shown below, the Sentry is attached to two mounting brackets that are, in turn, attached to the concrete fuel island via four anchor bolts. 6

8 Sentry Front 1. Locate the position of the Sentry. Remove the template from the back of this manual and place it on the ground. Carefully mark the centerline of each concrete anchor hole. 2. Remove the template and drill four holes as marked, with a 3/8 inch concrete bit. Drill each hole three inches deep. Remove excess dust from each hole. 3. Remove the left and right mounting brackets and place the brackets over the four holes, as shown. Insert the four Anchor Sleeves into the four holes. Place the Anchor Washers on the Anchor Bolts and screw them into the Anchor Sleeves. Tighten by hand (finger-tight only). 4. Place the Sentry down over the two mounting brackets and insert and tighten the four mounting screws. Remove the four mounting screws and carefully lift the Sentry straight up and off. Using a wrench, tighten the four anchor bolts. Be careful not to move the bracket s position. Now the Sentry may be replaced or removed, as necessary, by the four mounting screws. 5. The riser is mounted in the same manner. It is assembled on site but uses taller mounting brackets. The riser kit includes the taller mounting brackets. 7

9 Section 3.0 Mother Board Installation The mother board housing is installed in the rear of the Sentry housing via four ¼ -20 screws. The mother board housing is installed with the warning sticker at the top. The mother board housing cover is attached with 4 large thumbnuts. To remove, just unscrew the four thumbnuts and pull the cover off. When the cover is removed, the inside reveals two separate sections: 1. Low voltage on the left only low voltage wires or fiber optic cables can be placed in this side no signal wire over 24 volts is allowed. 2. High voltage on the right - only high voltage lines greater than 24 volts but less than 125VAC are allowed on this side. Fiber optics are also allowed on this side. WARNING: You must have training in the installation, service or maintenance of this equipment before working on it. Maintenance repairs must be done by authorized personnel only. Warranty work may only be performed by Trak certified technicians. Each section contains card edge connectors. Certain plug-in cards are available for each side. The cards, their function and placement are explained in Section 4. The low voltage sections contain a number of ten pin connectors whose function is explained in section 4.3. The high voltage section contains 4 ten pin in-line connectors whose function is explained in section 4.3. The very last card in the bottom right in the high voltage section contains a plug in transformer. This card cannot be removed from the field. It contains a 12 volt transformer that provides power to the plug in cards. Also on the right hand side is an ON/OFF switch. The proper label for the switch is located on a sticker on top of the switch. The OFF position is closest to the edge of the housing. J15 J14 J13 J12 J11 J10 J9 J8 J7 LOW VOLTAGE J1 J2 J3 HIGH VOLTAGE J5 J4 8

10 J32 J4 J5 ACH1 ACLO Section 4.0 Field Wiring 4.1 Overview The Sentry requires 115VAC for operating power. The Sentry can also control (turn on and off) the power (generally 115VAC) to a dispenser solenoid valve or dispenser pump motor. The Sentry also receives pulses in from the dispenser showing the number of gallons of product dispensed. All these controls power to the Sentry, pump on/off control and pulser inputs are wired into and through the Mother Board enclosure. The following sections describe how to connect power to the Mother Board (which routes that power to the Sentry Compact), how to wire the on/off controls to the dispenser and how to wire the pulser wires from the dispenser into the pulser circuits in the Mother Board. The Sentry is capable of either direct wire control (both pump on/off and pulser) or fiber optic control (both pump on/off and pulser). This manual, although describes fiber optics, deals primarily with hard wire connections. Please refer to the addendum that describes fiber optic hook up. 4.2 Connecting Power Power is required to operate the mother board assembly. It is designed for 115VAC only. It is connected to the power connector as shown below. Connect: 1. Connect AC power hot (115VAC) to ACH-IN 2. Connect AC neutral to ACLO-IN 3. Connect a green ground wire to GND T5B T5A K5B K5A T4A T4B K4B K4A T1B T1A ACHI2SW ACHIFSW ACLO AC2 12VACLO AC1 12VACHI ACSWLO ACSWHI GND ACLO-IN ACHI-IN ON/OFF White wire to Compact power Black wire to Compact power Ground AC Neutral AC Hot 9

11 The Mother Board also supplies power to the Compact. Those wires are connected to ACSWHI and ACSWLO as shown above. Those wires are the black and white wires that connect to the white Metro connector that is supplied with the Sentry Compact and connect to the matching black and white wire power connector on the back of the Compact. 4.3 Control Card Installation The low and high voltage sections contain multiple card edge connectors. The connectors are intended to have plug in cards inserted into them. Cards are either intended for the low voltage section OR the high voltage section. They are not interchangeable. Each card is keyed and will only fit into the appropriate section. Several slots are reserved for specific function cards. Slot J11 is reserved for the communication card. Slot J15 can be used for any low voltage card but when communicating to Trak tank level probes, the slot is reserved for the probe communication card. With the exceptions outlined above, any low voltage card can be used in any low voltage slot and any high voltage card can be used in any high voltage slot. In general some cards will physically fit or work better in some slots versus others but it is left up to the installer to make that decision. Cards currently available are: High Voltage 1. High voltage slot fiber optic transmit card (controls external Pump Control Modules) 2. High voltage slot fiber optic receive card (receives pulses from Pulser Power Unit) 3. High voltage slot direct wire pump control card Low Voltage 1. Low voltage slot fiber optic transmit card (controls external Pump Control Modules) 2. Low voltage slot fiber optic receive card (receives pulses from Pulser Power Unit) 3. Low voltage slot direct wire pulser input card 4. Low voltage slot communication card (several in this series depending on the communication selected hard wire, fiber optic, radio, etc.) (slot J11) 5. Low voltage slot tank probe communication card (slot J15) 10

12 Each card is explained below. 1. High voltage slot fiber optic transmit card. This card, shown below, is designed exclusively for the high voltage section. Since fiber optics is used to and from the card, the fiber optic cable can be placed in the high voltage section. This card can be used in any high voltage slot. The card has 6 fiber optic outputs. Each output can be used to drive a single Trak Pump Control Module (PCM). The maximum range for the cable is 100 feet. The fiber optic cable is inserted directly into the appropriate fiber optic cavity. Once inserted, the FO cable is held in with friction. No other clamp is necessary. For best results, the clear Teflon covering on the cable should be removed on the last ¼ of cable before it is inserted. 2. High voltage slot fiber optic receive card. This card is designed exclusively for the high voltage section. Since fiber optics is used to and from the card, the fiber optic cable can be placed in the high voltage section. This card can be used in any high voltage slot. The card has 6 fiber optic inputs. Each input can be used to receive pulses from a single pulser power unit (PPU). The maximum range for the cable is 100 feet. The card is shown here. The fiber optic cable is inserted directly into the appropriate fiber optic cavity. Once inserted the FO cable is held in with friction. No other 11

13 clamp is necessary. For best results, the clear Teflon covering on the cable should be removed on the last ¼ of cable before it is inserted. 3. High voltage slot direct wire pump control card. This card is designed to be utilized exclusively in the high voltage section. It is intended to directly control the solenoid valve, reset mechanism or internal suction pump of the dispenser. This card does not utilize the fiber optic control system. With this card, the dispenser control wiring is brought directly to the mother board and connected to the plug in connectors J32 or J34. This card is intended to control either two low power devices (solenoid, reset mechanism, or contactor) or one high power device (suction pump of the dispenser). These devices must all be rated 115VAC. The low power device must not exceed.5 amperes (1/2 amp). The high power device must not exceed 10 amps. The installer must be certain to follow these limitations or damage to the equipment will result. 4. High voltage slot direct wire pump control card controlling low power devices. The cards are wired into the mother board as follows for low power applications: Card Slot J1 1 st low power device to be controlled J32 - T1B and T1A 2 nd low power device to be controlled- J34- K1A and K1B A physical example of how this is wired is shown below. The same logic is used for wiring all other connections. The pump control card also has 2 jumpers on the back labeled JUMP. They consist of a piece of solid wire soldered across 2 terminals. These MUST be removed for the card to properly control 2 independent low power devices. They can be removed with a soldering iron or can be clipped with sharp pair of clippers. Card Slot J2-3rd low power J34 T2B and T2A 4th low power J34- K2A and K2B 12

14 K1A K1B T2B T2A K2A K2B T3B T3A K3A K3B H12 H11 H22 H21 H32 H31 H42 H41 H52 H51 T5B T5A K5B K5A T4A T4B K4B K4A T1B T1A Card Slot J3 - Card Slot J4 - Card Slot J5-5th low power J34 T3B and T3A 6th low power J34- K3A and K3B 7th low power J32 T4B and T4A 8th low power J32- K4A and K4B 9th low power J32 T5B and T5A 10th low power J32- K5A and K5B AC power ACH1 ACLO ACH1 ACLO ACH1 ACLO J3 J34 J33 J32 J2 J1 Solenoid 1 Low Power Device 1 Solenoid 2 AC power Low Power Device 2 5. High voltage slot direct wire pump control card controlling high power devices. These cards can also be utilized to control a single higher power device per card. In general these devices would include a selfcontained pumping motor. This type motor cannot exceed a ¾ horsepower motor or damage will result to both the control card and the Mother Board. In the previous section, each pump control card could control 2 low power devices. In this section each card can control only 1 high power device. The jumpers on the back of the card labeled JUMP must be intact. If they are not, the only options are to use a card with intact jumpers or to solder a jumper from across the 2 solder points for each jumper using a short piece of solid 14 awg wire. 13

15 K1A K1B T2B T2A K2A K2B T3B T3A K3A K3B H12 H11 H22 H21 H32 H31 H42 H41 H52 H51 T5B T5A K5B K5A T4A T4B K4B K4A T1B T1A Because these jumpers are in place and are necessary for proper high power control, the actual wiring to the dispenser must utilize both sections of the card. This is accomplished by wiring the primary control lines from the pump motor to two of the terminals (J34 KIB and KIA) as shown below. One also must run a jumper from the two terminals to J32 T1A and T1B as shown below. It is recommended that 16awg wire be used. These cards are wired as follows for high power applications: Slot J1 1 st high power connection J34 - K1B and K1A Jumper J32- T1A to J34 - K1A Jumper J32 T1B to J34 - K1B A physical example of how this is wired is shown below. The same logic is used for wiring all other connections. ACH1 ACLO ACH1 ACLO ACH1 ACLO J3 J34 J33 J32 J2 J1 Card Slot J2 - Card Slot J3 - Card Slot J4 - AC power P Pump Motor 2nd high power connection J34 K2B and K2A Jumper J34- T2A to J34 K2A Jumper J34 T2B to J34 K2B 3rd high power connection J34 K3B and K3A Jumper J34- T3A to J34 K3A Jumper J34 T3B to J34 K3B 4th high power connection J32 K4B and K4A 14

16 Pulser 1 Pulser 6 Pulser 5 Pulser 4 Pulser 3 Pulser 2 Pin 1 Pin 2 Card Slot J5 - Jumper J32- T4A to J32 K4A Jumper J32 T4B to J32 K4B 5th high power connection J34 K5B and K5A Jumper J34- T5A to J34 K5A Jumper J34 T5B to J34 K5B 4.4 Pulser Card Installation There are two types of pulser cards 1) Fiber optic (shown in C2 above) and 2) Hard Wire. The fiber optic cards are designed to be used either in a low voltage slot or a high voltage slot. They are not interchangeable they will only fit into the proper voltage slot. The hard wire pulser card is designed for the low voltage slots only. Each hard wire card has 6 pulser inputs on the back of the card as shown to the right. Pin 1 is the same for each input. These are 2 pin Molex connectors which are crimp on pins. For long term reliability, the pins should be soldered after crimping. Trak recommends 2 conductors shielded 26 awg wire with 600 VAC insulation. Two conductors are wired from each pulser input to the physical pulser that is attached at the dispenser. The pulser card is a multifunctional card. It is designed to work with many different pulsers. Many pulsers are either electronic or have an electronic output commonly called open collector. In the pulser configurations shown on page 11, the pulser card can be reconfigured to match whichever pulser configuration is required. The first schematic shows the card as it is shipped from the factory. The next two show both the pulser used to connect to an electronic powered pulser and a nonpowered mechanical pulser. In the PLS configuration, the card can supply low voltage DC power to an electronic pulser circuit. This typical circuit is shown on page 12. However, if additional voltage is required, a Pulser Power Card can be utilized (supplied by Trak) that will insert into any unused low voltage mother board slot. This circuit is shown on page 13. It is not the intent of this section to fully describe all possible pulser configurations but rather to serve as a general guideline to assist in connecting to different types. Trak is always willing to provide telephone assistance when necessary. 15

17 Once a decision has been made as to the configuration necessary, the card can be modified to meet the criteria. If it is necessary to remove the diode, they can be either unsoldered or clipped off with a pair of sharp cutters. The card is shipped with jumpers on the CTC/PLS headers. To change, simply pull the jumper off and replace in the proper spot. LOW P1 P2 P3 P4 P5 P6 PLS CTC Diodes CTC PLS 16

18 +5 1 P1 PLS CTC + 2 1K 1M 10K +5 CTC Standard Card +5 PLS 1 + P1 Pulser input signal high 2 To Pulser Power Card ground connection 1K 10K 1M PLS Configuration: Used for powered pulsers - typical Veeder Root pulser powered by Trak Pulser Power Card Pulser input signal ground 1 Remove Diode + P1 Pulser input signal high 2 1K 1M 10K +5 CTC Configuration: Used for non powered pulsers - typical Trak pulser 17

19 Described below is a typical connection to an electronic pulser that requires a limited amount of power from the Trak Hard Wire Pulser Card. This configuration also is correct for using a non-powered (dry contact closure) pulser switch typical of Trak supplied pulsers. The two wires of the pulser simply connect to pins 1 & 2 of any pulser input connector on the hardwire pulser card. How to connect Sentry Gold hardwire pulser card to Gasboy Electronic 9800 Series Dispensers +5V 1 2 U4 4 3 P1 1 Pulse 1 Red P1 Pin 2 Pin 1 1k Remove CR1 10k U3 C06425 ASSY Gasboy 9800 Pump I/F PCB Pulse 2 3 Return 4 N/C Green White Black Leave black capped in junction box P2 Pin 2 Pin 1 1k +5V Remove CR2 10k Trak Hardwire Pulser Card + Place both jumpers on 'CTC' setting Note that each pulser input connector on the pulser card is a 2 pin Molex. When viewing the card from the component side with the pins at the top, the right hand side pin is the common return pin. The diodes can be removed by desoldering or clipping. Sometimes a dispenser pulser circuit requires more than 5 volts to operate as shown above. In these cases Trak supplies a Pulser Power Card. This is simply a card that plugs into any low voltage slot on the mother board and supplies 12VDC out each of the 2 pin Molex connectors. It is configured as shown below. The resistor shown as to be determined has to be sized according to the dispenser pulser manufacturer and the actual placement in the circuit may vary depending on the manufacturer recommendations. 18

20 How to connect Sentry Gold hardwire pulser card to a pulser that requires extended voltage to operate Resistor to be determined by dispenser requirements P1 Pin 2 Pin 1 Trak Pulser Power Card +12 VDC GND 1 2 U3 4 3 Pulser Power Return P1 Pin 2 Pin 1 1k 10k - + Dispenser Pulser +5V Trak Hardwire Pulser Card Place both jumpers on 'PLS' setting Note that each pulser input connector on the pulser card is a 2 pin Molex. When viewing the card from the component side with the pins at the top, the right hand side pin is the common return pin. 4.5 Communication Card and External Comm. Cable Installation Slot J11 is reserved for all communication cards. There are multiple type communication cards available: Hard wire current loop Fiber Optic Radio 1 watt WiFi a/g Depending on the type card selected, various other connectors will be attached to connection points on the mother board in the middle of the low voltage section. As a minimum, the Compact has two connectors that must be attached to the mother board. The wires should be feed into the mother board housing through the rectangular hole in the left side. 19

21 MASTER ADR >15 J24 J22 J24 J37 J36 1. The main external communication cable from the Compact Reader connector and labeled RS-232 on the wire itself is a red/black/brown cable combination that has a 3 pin Molex female on the end with a 3 pin Metro connector in the middle. It plugs into the 3 pin connector labeled SBC232 shown below. There are two 3 pin connectors right next to each other and either one is fine. They are also labeled J36 and J The main internal communication cable from the Compact Comm. connector labeled 485 on the wire itself is a green/white/blue cable combination that has a 4 pin Molex female on the end. It plugs into the 4 pin connector labeled MASTER ADR>15 shown below. There are two 4 pin connectors right next to each other and either one is fine. They are also labeled J22 and J24. J13 J12 LOW VOLTAGE SBC232 LOCAL-HW J11 J10 Card slot J11 is reserved for the communication cards. There are several items that require attention depending on the communication card inserted. 20

22 1. Hard Wire Current Loop - This card converts the serial data from the Compact into long distance capability referred to as current loop. This circuit is a 4 wire circuit (2 twisted pair) of 20 to 24 awg shielded wire. It is normally capable of transmitting data reliably to 2,000 feet. The wire at the Compact end is terminated into a 4 pin Molex plug. This plugs into the mating 4 pin connector labeled above as LOCAL-HW or J Both radio cards and the FO card utilize connectors on the cards themselves and no other connectors are attached to the mother board. The radio card utilizes either an internal connector connected directly to an internal antenna or is connected to an adapter cable that allows the antenna to be mounted externally on top of the Sentry housing. Section 5.0 Compact Installation 5.1 Overview Final installation is accomplished with the insertion of the Compact into the Sentry housing. Regardless of the options selected, all Compacts will fit into any housing. The Compact simply has to have several electrical connectors snapped into place and the housing has to be inserted into the housing and locked in place. 5.2 Electrical Connections The Compact has 3 connectors on the rear panel. They are: 1. Reader wiring to key reader (if part of system) and main external communication wiring cable 2. Power wiring to main power (115VAC) and wiring to speaker on speaker panel 3. Comm. wiring to main internal communication cable and wiring to the card reader (if part of the system) on the speaker panel These must be plugged into the back of the Compact. For the Reader & Power Connectors: Rotate collar counter clockwise to release, pull out of connector. When replacing the connector it is very important to line up the connectors properly. Line up the dots located on the base and collar of the connector. Excessive pressure is not required; if the connector is lined up properly it will pop in with minimal effort. Once a connector is plugged in, rotate the collar clockwise to lock it in place. 21

23 For the Comm. Connector: It is different from the Reader and Power. It does not have a collar. To plug in the connector simply line up the dots and push into mating connector. It should click and lock into place. 5.3 Inserting the Compact into the Housing The Compact is inserted into the housing by tilting the top of the Sentry Compact slightly towards the housing as shown. The groove in the top of the Compact will fit into the metal top of the housing. a. Make sure to tuck all wires into the Housing, be careful not to pinch any wires. b. Line the groove along the top of the Sentry Head with the top edge of the opening. c. Push the Sentry Head upwards as far as it will go. d. Push the bottom end toward the Housing. e. Make sure edges are flush and no wires are pinched between the Housing and the Sentry head. f. Slide Sentry Head downwards until it comes to rest on the bottom edge of the opening. g. Lock the Sentry Head in place with the Housing key. 22

Manual No: Revision: F. Relay Output Modules. Installation Guide

Manual No: Revision: F. Relay Output Modules. Installation Guide Manual No: 576013-614 Revision: F Relay Output Modules Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations Navigator II Installation MANUAL For Static and Pan/Tilt Configurations Document Number: 432-0001-00-12, rev 100 FLIR Systems, Inc., 2008. All rights reserved worldwide. No parts of this manual, in whole

More information

KBMG MULTI-SPEED BOARD

KBMG MULTI-SPEED BOARD TM INSTALLATION AND OPERATION MANUAL KBMG MULTI-SPEED BOARD KB Part No. 8833 Multi-Speed Board for KBMG Series Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

PLC Racks IC697CHS782/783

PLC Racks IC697CHS782/783 5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

MegaTrak MCU-9000 Harness Wiring

MegaTrak MCU-9000 Harness Wiring MegaTrak MCU-9000 Harness Wiring Contents: 1. MCU9000 Connector Pin-Out Schematic 2. MCU9000 Connections when replacing an MCU3000 3. MCU9000 Connections Using 120VAC ( Hot ) Hook Switch (RS485 cable)

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product. LINE VOLTAGE TESTER USER S MANUAL CT101 Please read this manual carefully and thoroughly before using this product. KEY FEATURES Visual indication of AC or DC voltage Easy to use approved Safe for CAT

More information

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Topic General Safety Warnings Ganging Hardware Electrical Circuits Table of Contents Page End-to-End (Page 4) End-and-Back

More information

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity DirectCommand Kit 4100800 1 Cable Installation Kit 2000901-1 1 Dielectric Grease 2002872

More information

NOTE: Read the instructions completely through before beginning actual installation.

NOTE: Read the instructions completely through before beginning actual installation. CONSOLE CONNECTOR KIT 7850 INSTALLATION INSTRUCTIONS FOR USE WITH: Various Two-channel Organs LESLIE Speaker Models 705, 705C, 720 KIT CONTENT Console Connector 138488 Switch Assembly, Cable Assembly,

More information

Universal Keying Adapter 3+

Universal Keying Adapter 3+ Universal Keying Adapter 3+ The Universal Keying Adapter Version 3+ kit will allow you to key nearly any transmitter or transceiver with a straight key, electronic keyer, computer serial or parallel port

More information

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series Note: Indented items indicate parts included in an assembly listed above. Part Name / Description Part Number Quantity Direct Command Spra-Coupe 7000 Kit 4100531 1 Liquid Product Control Module 4000394

More information

Now with Picture Memory

Now with Picture Memory Intrasonic Technology, Inc. Color Video Door Phone / Intercom Installer s Manual Model No.V304KIT-R Now with Picture Memory Please read this manual carefully before the products are installed.technical

More information

ICS Entrance Management Sign Installation Guide. Version 1.0

ICS Entrance Management Sign Installation Guide. Version 1.0 ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

Instruction Sheet Board Style Low Water Cutoff

Instruction Sheet Board Style Low Water Cutoff Instruction Sheet Board Style Low Water Cutoff 102-305 SUPERSEDES: REVISION E DATED December 12, 2007 #5401173-REV F PLANT ID 001-3902 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number: Minarik Variable Speed AC Motor Drives AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY INSTALLATION INSTRUCTIONS Document Number: 250-0297 These instructions apply to models rated: 7.5 25

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

Quicksilver 606 TR-606 CPU Upgrade

Quicksilver 606 TR-606 CPU Upgrade Quicksilver 606 TR-606 CPU Upgrade D650C 128 Installation Guide Social Entropy Electronic Music Instruments TABLE OF CONTENTS WARNINGS... 1 OVERVIEW... 2 WHAT'S IN THE BOX... 3 OPENING THE TR-606 CASE...

More information

InView Marquee Message Display

InView Marquee Message Display Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-40 9/0 INSTALLATION INSTRUCTIONS Original Issue Date: 9/0 Model: Automatic Transfer Switches Equipped with the Programmable Controller Market: ATS Subject: External Battery Supply Module Kit GM69-KP

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

M215-Z Safety Information (M LL-IG-ZC)

M215-Z Safety Information (M LL-IG-ZC) M215-Z SAFETY M215-Z Safety Information (M215-60-2LL-IG-ZC) This document contains important instructions to use during installation of the M215-Z Zep Compatible Microinverters. To reduce the risk of electrical

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt DirectCommand Installation Ag Leader Technology Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity DirectCommand Kit 4100852 1 Cable Installation

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

!There are two kit models. The ZCTK-120 is designed to operate with.!the pulse output is isolated from the mains line voltage. A pull-up resistor

!There are two kit models. The ZCTK-120 is designed to operate with.!the pulse output is isolated from the mains line voltage. A pull-up resistor CAUTION: Please make sure you have or have access to the skills necessary to assemble and use this product. Always secure the case with the included screws before applying electrical power to the power

More information

Part Name/Description Part Number Quantity

Part Name/Description Part Number Quantity Part Name/Description Part Number Quantity Direct Command Kit 4100883 1 Installation Instructions 2006336 1 Hardware Kit Large Module 2001354-1 2 Cable Installation Kit 2000901-1 1 Quick Reference Card

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. BPL SERIES INSTALLATION INSTRUCTIONS Important Warning THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This product must be installed in accordance with National Electrical

More information

C-POWER AC AUTOMATIC CONTROL

C-POWER AC AUTOMATIC CONTROL Issue 1 Print 1 C-POWER AC AUTOMATIC CONTROL INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model: 93 ACMC100I A Charles Industries, Ltd. All rights reserved. Printed in the United States of America. Issue

More information

MDE-4815B INSTALLATION MANUAL. This document is based on Orpak s WGT outdoor unit installation manual P/N

MDE-4815B INSTALLATION MANUAL. This document is based on Orpak s WGT outdoor unit installation manual P/N MDE-4815B WGT Outdoor Unit INSTALLATION MANUAL This document is based on Orpak s WGT outdoor unit installation manual P/N 817439300 SAFETY CONSIDERATIONS Read all warning notes and instructions carefully.

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

High Speed Remote I/O Module

High Speed Remote I/O Module High Speed Remote I/O Module EXF-RC15 The Unitronics EXF-RC15 is a High Speed Remote I/O Module that offers three High Speed Counter inputs and four high speed outputs. Overall, the EXF-RC15 offers 9 digital

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

Control Box Setup - PRSalpha

Control Box Setup - PRSalpha 888-680-4466 ShopBotTools.com Control Box Setup - PRSalpha Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Parts List: Hooking Up a PRSalpha Gantry Tool Powering the

More information

Rotork Fairchild PAX1 Linear Actuator User s Manual

Rotork Fairchild PAX1 Linear Actuator User s Manual Rotork Fairchild PAX1 Linear Actuator User s Manual Product Overview The PAX1 is a flexible low voltage DC powered linear actuator featuring a 5 mm maximum thrust rod stroke moving at speeds up to 0 mm/min

More information

V8-80HS-1 SERIES OF HIGH-SPEED MOTORIZED ZOOM LENSES

V8-80HS-1 SERIES OF HIGH-SPEED MOTORIZED ZOOM LENSES X684 V8-80HS-1 SERIES OF HIGH-SPEED MOTORIZED ZOOM LENSES Copyright 2000 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice. Vicon and its logo are registered

More information

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits. This Datasheet for the IC660BBD110 Block 115Vac Input 16 Circuits http://www.cimtecautomation.com/parts/p-14435-ic660bbd110.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Product 7160-0318-00 THROUGH 7160-0318-12 PANASONIC TOUGHBOOK CF-31 DOCKING STATION This instruction sheet is for the following products: Panasonic Toughbook CF-31 docking station

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

Bid Specifications and General Description

Bid Specifications and General Description BID-SPEC_PV100 Rev. 0 Bid Specifications and General Description OPW Petro Vend 100 Fuel Control System Part 1. General Overview 1.1 Summary This document describes the minimum required technical and compliance

More information

Copy Machine Reader. Installation and Setup Guide

Copy Machine Reader. Installation and Setup Guide Copy Machine Reader Installation and Setup Guide CONTENTS 1 COPY MACHINE READER INSTALLATION 1 Overview 1 Reader Specifications 3 CR1120/CR1122 INSTALLATION 3 Copier Interface 3 AC Electrical 3 Communications

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors

More information

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-6B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112 SELECTRONIX, INC. WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL Models: SLC2102-SLC2112 SLC2102X-SLC2112X SLC2152-SLC2162 SLC2170-xx Relay

More information

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper Caution 1 Read instructions through completely before proceeding; keep them for future

More information

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

and Network Interface Modules Installation Instructions

and Network Interface Modules Installation Instructions 4010-9817 and 4010-9821 Network Interface Modules Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the

More information

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0429-001 TNP121UL Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the UL Listed TNP121UL, Tilt N Plug Jr. Interconnect Box is greatly appreciated.

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

User s Manual Pulse Encoder Interface Module OTAC-01

User s Manual Pulse Encoder Interface Module OTAC-01 Drive IT Low Voltage AC Drives User s Manual Pulse Encoder Interface Module OTAC-01 2 Safety WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians

More information

OilCop Component Wiring Installation Manual

OilCop Component Wiring Installation Manual OilCop Component Wiring Installation Manual This info sheet contains important information. READ AND KEEP FOR REFERENCE. 2311 S. Edwards Wichita, KS 67213 TEL: 316-943-5477 FAX: 316-943-4760 TOLL FREE:

More information

LED Maintenance Instructions

LED Maintenance Instructions Chapter 5 LED Maintenance Instructions This guide describes the maintenance procedures for the LED portion of your DayStar or TekStar sign. 1.800.237.3928 stewartsigns.com Rev1802 Intentionally Left Blank

More information

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel. LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com

More information

LED. Sign Module. Assembly Manual

LED. Sign Module. Assembly Manual LED Sign Module Assembly Manual 6/14/2002 3:10 PM 6 2 3 3 E. S a w g ra s s R d S a ra s o ta, F L. 3 4 2 4 0 (9 4 1 )3 7 7-5 7 7 5 F A X(9 4 1 )3 7 8-4 2 2 6 www.acscontrol.com Table of Contents Table

More information

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV OVERVIEW The STR9 ELV is a long run, low power, linear surface mount LED lighting system designed for exterior architectural lighting applications. This guide contains important information on planning

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS SEE SAFETY WARNING ON PAGE 6 SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY IS DESIGNED TO BE USED WITH KBAC 3G SERIES DRIVES ONLY KBAC 3G SERIES MODELS CONTAIN THE "(3G)" DESIGNATOR ON THE PRODUCT LABEL

More information

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO. INSTRUCTION MANUAL RA 59 RACK ADAPTER KEPCO INC. An ISO 9001 Company. MODEL RA 59 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for the following Model and associated serial

More information

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

VG-305A AC Traffic Light Controller Kit

VG-305A AC Traffic Light Controller Kit Galak Electronics Electronic kits and components Website: GalakElectronics.com Email: sales@galakelectronics.com Phone: (302) 832-1978 VG-305A AC Traffic Light Controller Kit Thank you for your purchase

More information

Butterfly Laser Diode Mount

Butterfly Laser Diode Mount LM14S2 Butterfly Laser Diode Mount Operating Manual LM14S2 Laser On TEC Driver LD Driver THORLABS, Inc. Ph: (973) 579-7227 435 Route 206N Fax: (973) 383-8406 Newton, NJ 07860 USA www.thorlabs.com 10614-D02

More information

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

ABM International, Inc. Lightning Stitch Checklist 9/13/2013 ABM International, Inc. Lightning Stitch Checklist 9/13/2013 1) Piggy backed board assembly (1) Piggy back board assembly tested? Yes No 24v passed XB passed XA passed YB passed YA passed SAFE passed S/S

More information

Installing the DX LCD Display

Installing the DX LCD Display DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION S6 USER S MANUAL TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION SECTION 4 SLIDE CONFIGURATION ACCESSORIES SECTION 5 RACK MOUNT

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120. Vision OPLC Installation Guide Vision120 This guide provides basic information for Unitronics Vision120. General Description V120 OPLCs are micro-oplcs, rugged programmable logic controllers that comprise

More information

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03 Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

PRO REMOTE 25 CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Jamieson Equipmen toll free 800

PRO REMOTE 25 CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Jamieson Equipmen   toll free 800 PRO REMOTE 25 CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4 3.0 INSTALLATION...4

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information