MANUAL SPEED SENSOR MSPEED EX

Size: px
Start display at page:

Download "MANUAL SPEED SENSOR MSPEED EX"

Transcription

1 MANUAL SPEED SENSOR MSPEED EX 1. INTRODUCTION DESCRIPTION CONNECTING MSPEED CONNECTING MSPEED TO THE JETI BOX CONNECTING MSPEED TO THE DUPLEX RECEIVER CONNECTING MSPEED TO THE DUPLEX RECEIVER VIA THE EXPANDER MSPEED MENU ACTUAL VALUE MIN / MAX SETTING ALARMS SERVICE FIRMWARE UPDATE INSTALLATION TECHNICAL DATA FOR MSPEED WARRANTY... 8 Publisher JETI model s.r.o

2 1. Introduction MSPEED is a sensor which measures the speed of a flying model through the air, to provide the indicated airspeed (IAS). The reporting of airspeed can be very instructive with regard to the control of a flying model, for example allowing the pilot to determine the models stall speed and set an alarm to indicate when the model falls below this speed. Another function of the sensor is to allow the pilot to set a desired speed and a step above or below this speed at which an acoustic signal should be sounded by the transmitter module. To facilitate easier reading of the indicated airspeed, a bar graph is displayed marking the appropriate configured steps. The measurement of airspeed is based on the principle of change in dynamic pressure, measured by a pitot tube, which is connected by silicon tubing. With the help of the wireless Duplex system, this sensor information can be reported to the pilot in realtime, allowing immediate feedback in airspeed changes and a deviations from the configured steps. 2. Description MSPEED consists of a base unit and a pitot tube with static pressure measurement, connected by silicone hoses. The base unit includes the sensor for measuring the relative pressure with two entrances. One entrance is marked red and other is clear. The pitot tube has two corresponding exists, one marked red, the other not. To ensure correct operation, the red tube should be connected between the base unit and the pitot using the marked input/output. The clear tube should be connected between the unmarked input/outputs. 3. Connecting MSPEED The base unit features two three-wire cables. The cable with the red JR plug, marked INPUT provides control signals to the unit. The other cable marked EXT (black plug) allows data transfer between the sensor and the Duplex system or the Jeti Box. 3.1 Connecting MSPEED to the Jeti Box In this case, the Jeti Box requires a power-supply of between V, such as a receiver battery, which should be connected to the socket marked +, - of the Jeti Box. The three-wire cable from the MSPEED, with the black plug, should be connected to the appropriate socket of the Jeti Box (The socket marked pulse, +, -). The red plug of the MSPEED base unit, is not required. Please note in this configuration, alarms cannot be generated, but will be displayed on the Jeti Box screen. -2-

3 3.2 Connecting MSPEED to the Duplex Receiver In this case, MSPEED is connected directly to the Duplex receiver, using the socket marked EXT. The sensor takes its power from the receiver. The black plug from MSPEED should be inserted into the EXT. Socket of the receiver (Observe correct orientation) and the red plug from MSPEED can optionally be connected to a spare channel, in order to control the alarm signals. 3.3 Connecting MSPEED to the Duplex Receiver via the Expander In this case, additional sensors can be connected to the receiver, if required, via the Expander. The three-cable wire from the MSPEED with the black plug, should be connected to the Expander, observing the correct orientation. The Expander should be connected to the Receiver via the Expanders black JR plug, into the socket marked EXT. on the Receiver. The optional red plug of the MSPEED can be connected to a spare receiver channel, if desired. 4. MSPEED Menu For parameter setting and data read-outs, the Jeti Box terminal is used. After connecting MSPEED as per section 3 and assuming that if required, the Jeti Box is connected to your Duplex transmitter module; then the MSPEED sensor can be chosen on the Jeti Box. The initial screen shows the sensor identification and the actual measured speed. The second line shows the bar chart and the current speed. The bar chart has eight positions and the > character indicates a speed step, which is equal to the Step of graph value within the BAR GRAPH settings.. By long pushing down button R (right) -3-

4 a fast deletion of all measured parameters can be triggered. Fast deletion is indicated in the first line of the display by an asterix *. 4.1 ACTUAL VALUE MSPEED MENU: Actual Value By pressing the D (Down) key of the Jeti Box, we can see the actual measured values. Actual speed Shows the actual measured speed. Can be reset by simultaneously holding L and R keys (Left and Right), which should be performed if the model is at rest. Temperature Shows the current temperature measured by MSPEED. 4.2 MIN / MAX MSPEED MENU: MIN / MAX - By pressing the D (Down) key of the Jeti Box again, we can see the recorded extremes of speed and temperature, which have occured. Recorded extremes are automatically deleted after power-up only when the current actual speed exceeds that specified by the Setting Bar Graph Minimal Value setting. If this value is not exceeded, then the recorded extremes from the previous use of the sensor are shown. MIN/MAX Speed Shows the minimum and maximum speed recorded during the last operation. MIN/MAX Temp. Shows the minimum and maximum temperature recorded during the last operation. 4.3 SETTING MSPEED MENU: SETTING By pressing the D (Down) key of the Jeti Box again, we access the settings menu of the sensor. Erase Data By pressing the Down key, the minimum and maximum values are erased. -4-

5 BAR GRAPH - by pressing the Down key, the options for the bar graph are displayed Minimal value The minimum value of the graph. When this value is exceeded, the first portion of the graph is filled and any minimum and maximum values are erased. Actual speed [km/h] Step of graph Step of the bar graph. > > > > For example: If the Minimal value is 20 km/h and Step of graph is 10 km/h and the current speed is 51 km/h, then the bar graph will appear as follows: SPEED MONITOR By pressing the down key, we access the setttings menu for the speed indicator, which serves to aid in keeping your model at an optimum speed and aid awareness of changes in that speed. Beep of speed Set the independent audible speed indicator. This does not affect the alarm. ON Sound is switched on permanently. ON OVER Sound is only given when speed is above Setpoint speed. ON BELLOW - Sound is only given when speed is above Setpoint speed, OFF - Sound is off (Does not affect the alarm). Setpoint speed Expected average speed. Level of speed The step in speed with which the sound changes Period of beep The length of the sound The graphic below shows the speed curve in relation to time. Setting the desired speed value ( Setpoint speed ) and speed levels ( Level of speed ) determines how the acoustic signal will change. If the current speed is higher than the desired speed, this is signalled by beeps and the appropriate number of tones proportional to the difference in speed. Speed below the desired level is indicated with long notes and the number of tones in this case determines the shortfall of speed. These sounds can be disabled in the Settings Control signal option menu. -5-

6 CONTROL SIGNAL By pressing the Down key, we can modify options relating to the input control signal. This allows simple switching on/off of the audible alarms generated by MSPEED. Trigger level Set the trigger speed for recording of data. For example if the trigger level is 1.50ms and Reverse is OFF, as soon as a speed of 1.50ms is exceeded, then data recording begins and any previously recorded maximum/minimum values are deleted. If the speed is less than the trigger level, no data is recorded and previously recorded data remains unaffected. No acoustic signalling will be given in this case. If the option SETTING SPEED MONITOR BEEP OF SPEED is set to ON and the control wire is not connected, then the acoustic signal will be switched on permanently. Revese Reverse the control signal input. MAIN By pressing the down arrow of the Jeti Box, the main menu for MSPEED is displayed, where the units of speed and alarm signal can be programmed. Speed unit Specify the unit of measurement for speed, as one of: km/h Kilometres per hour m/s Metres per second mph Miles per hour Beep speed Alarm - Set the more code letter to be represented by the Duplex transmitter module, should the speed sensor signal an alarm condition. 4.4 Alarms MSPEED MENU: ALARMS By pressing the Down arrow, we can access the alarm settings menu for the speed sensor. Should an alarm condition be reached, the 2nd line of the Jeti Box (If connected) will indicate the condition and the transmitter module will emit an audible alarm according to the morse code character specified in the main settings. High speed Al. The speed which if exceeded, will raise an alarm condition. Low speed Al. The speed below which an alarm condition should be raised. 4.5 SERVICE MSPEED MENU: SERVICE by pressing button D (arrow down) you will change to depiction of the firmware version and to renewal of the sensor default setting. Factory Defaults by simultaneous pressing of arrows R and L (right and left) the factory settings of the MSPEED are loaded. MSPEED v. xx.xx ID xxxxx:xxxxx product marking with firmware version and series number (ID). -6-

7 5. Firmware Update The equipment firmware may be updated by a PC via the converter unit JETI USB Adapter. In the USB Adapter instructions you will find a description of the installation procedure of the USB Adapter controller as well as the update program. 6. Installation The main MSPEED sensor unit can be placed directly in the fuselage or installed in the wings. Please avoid direct contact of heat sources, such as batteries, controllers and regulators. The pitot tube must be installed outside zones of airflow directly behind propellers. As an example, the pitot tube may be installed on the wing of a single-engined model aeroplane, or on the fuselage of a twin-engined model. In single engined models, it is advantageous to install the pitot tube at the leading edge of the wing at the chord. In twin or multi-engined models, it is best to install the pitot tube in the nose of the model or at a minimum distance of 2cm from the fuselage side. -7-

8 7. Technical data for MSPEED Technical Data MSPEED Sensor unit dimensions (mm) 22x25x13mm Pitot tube dimensions (mm) 54x3 mm Weight (complete) 21g Precision 5 km/h Limit km/h Operating temperature 0-85 C Operating Voltage 3,5-8,4V Current 10mA 8. Warranty A 24-month warranty is provided by the manufacturer from the date of sale on the condition that the unit has been operated within the required voltage limits and there is no physical damage. All servicing during and after the warranty period, is provided by the manufacturer. Wishing you pleasant flights: JETI model s.r.o. Příbor, -8-

INSTRUCTION MANUAL VOLTAGE REGULATOR MAXBEC2D PLUS EX

INSTRUCTION MANUAL VOLTAGE REGULATOR MAXBEC2D PLUS EX VOLTAGE REGULATOR MAXBEC2D PLUS EX Released by JETI model s.r.o. 29. 10. 2014 CONTENT 1. INTRODUCTION... 3 2. DESCRIPTION... 4 2.1 MAXBEC2D PLUS... 4 2.2 MAGNETIC SWITCH... 4 2.3 RC SWITCH... 5 3. CIRCUITS...

More information

USER MANUAL MBAR EX By JETI model s.r.o

USER MANUAL MBAR EX By JETI model s.r.o USER MANUAL MBAR EX By JETI model s.r.o. 14. 11. 2014 CONTENTS 1. INTRODUCTION...3 2. MAIN FEATURES...3 3. PLACEMENT OF MBAR EX SENSOR...3 4. CONNECTING THE MBAR EX SENSOR...4 5. SETTING VIA JETIBOX...5

More information

USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n

USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H SW version 3.n CONTENT 1. General description 1 2. Getting started 2 2.1 Insert a SIM card 2 2.2 Insert the batteries 2 2.3 Enter the

More information

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions CM-120TX Wireless Digital Keypads Installation Instructions Package Contents - (1) Keypad and faceplate assembly - (1) Foam gasket (CM-120W only) - (2) #6-32 x 1 S/S Phillips screws - (2) #6-32 x 1 Tamperproof

More information

Translated by R.Whitehead (my best effort accuracy is not guaranteed) Specifications and operating instructions

Translated by R.Whitehead (my best effort accuracy is not guaranteed) Specifications and operating instructions UniSens-E The small yet powerful telemetry sensor measures and transmits Voltage / current / capacity / power / energy /Brushless rpm / height / Climb Specifications and operating instructions 1 Introduction

More information

Operating Instructions for Memo-Chip BL2

Operating Instructions for Memo-Chip BL2 Operating Instructions for Memo-Chip BL2 Software at: http://www.lignomat.com/bl2/ Connection between BL2 and BluePeg Sensor via Adapter RH Monitoring ambient conditions Connection between BL2 and BluePeg

More information

Multifunction instrument AMI 310

Multifunction instrument AMI 310 Multifunction instrument AMI 310 Table of contents 1 Presentation...6 1.1 Instrument description...6 1.2 Remove battery...7 1.3 Insert SD card...7 2 Connections of the AMI310...8 2.1 Main features...8

More information

V0STAT51P-2 Programmable Wired Controller

V0STAT51P-2 Programmable Wired Controller PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF V0STAT51P-2 Programmable Wired Controller Bulletin No. 210766 March 2016 Grouping - Controller can control up to 16 indoor units on the same

More information

AVM-8880 USB Logging Anemometer

AVM-8880 USB Logging Anemometer AVM-8880 USB Logging Anemometer Introduction This digital USB logging Anemometer is a precision instrument. It measures airflow levels and has the facilities to record and store measured valves when plugged

More information

WARNING!!!!!!!!! IMPORTANT INFORMATION: READ BEFORE INSTALLATION!

WARNING!!!!!!!!! IMPORTANT INFORMATION: READ BEFORE INSTALLATION! V_Net Relay Module Installation Instructions: Part Number: 230-VM-RELAY WARNING!!!!!!!!! IMPORTANT INFORMATION: READ BEFORE INSTALLATION! The relay outputs of the 230-VM-RELAY module may turn on when not

More information

Flight Computer 1.0. Users Guide.

Flight Computer 1.0. Users Guide. Flight Computer 1.0 Users Guide. Torrent d en Puig, 31. 08358, Arenys de Munt, Barcelona,Catalonia,Spain E-mail: sales@xicoy.com. Fax: +34 933 969 743 web: www.xicoy.com Xicoy WEEE register number: ES004749

More information

VT 210 Thermo-Hygrometer-Anemometer

VT 210 Thermo-Hygrometer-Anemometer VT 210 Thermo-Hygrometer-Anemometer Table of contents 1. Presentation...6 1.1. Instrument description...6 1.2. Key description...6 1.3. Remove battery...7 2. Connections of the VT210...8 2.1. Main features...8

More information

USER MANUAL Mobeye CM-Guard CM2000

USER MANUAL Mobeye CM-Guard CM2000 USER MANUAL Mobeye CM-Guard CM2000 SW version 3.n Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual.

More information

Manual Light Driver 5.0

Manual Light Driver 5.0 1 Manual Light Driver 5.0 2 Content Change History... 3 Product description... 4 Specifications... 5 Measurements... 6 Layout and connection assignment... 7 Start-up... 8 Factory settings... 8 Individual

More information

Jadis I-35. Owner's Manual. Integrated amplifier

Jadis I-35. Owner's Manual. Integrated amplifier Jadis I-35 Integrated amplifier Owner's Manual Table of contents Introduction Warning Unpacking and checking Description Installation instruction Tube position How to match your amplifier to your loudspeaker

More information

HOBO Temp/RH 3.5% Data Logger (UX ) Manual

HOBO Temp/RH 3.5% Data Logger (UX ) Manual HOBO Temp/RH 3.5% Data Logger (UX100-003) Manual The HOBO Temp/RH data logger records temperature and relative humidity (within 3.5% accuracy) in indoor environments with its integrated sensors. Using

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS 2018 Lennox Industries Inc. Dallas, Texas, USA OPERATION INSTRUCTIONS V0STAT52 Wireless Indoor Unit Controller CONTROLS 507459-04 05/2018 This manual must be left with the owner for future reference. IMPORTANT

More information

PROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 -

PROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 - PROFESSIONAL WIRELESS WEATHER STATION Operation Manual - 1 - OVERVIEW Outdoor sensor: 1. Wind Vane 2. Wind Speed Sensor 3. Solar panel 4. Battery compartment 5. LED Indicator: light on for 4 seconds during

More information

Elotech Standard Protocol. for Single R8200 SC

Elotech Standard Protocol. for Single R8200 SC Elotech Standard Protocol interface description / network protocol for Single R8200 SC ELOTECH Industrieelektronik GmbH Verbindungsstraße 27 D - 40723 HILDEN FON +49 2103 / 255 97 0 FAX +49 2103 / 255

More information

M A C 3 Wind Speed Alarm & Controller

M A C 3 Wind Speed Alarm & Controller M A C 3 Wind Speed Alarm & Controller Installation Instructions Thank you for purchasing the MAC3 wind speed alarm and controller. This manual is designed to lead you through a step-by-step process to

More information

Vega ASI-4. Introduction. 1 Features. Airspeed Indicator (ASI) Operating Manual English 1.00

Vega ASI-4. Introduction. 1 Features. Airspeed Indicator (ASI) Operating Manual English 1.00 Vega ASI-4 Airspeed Indicator (ASI) Operating Manual English 1.00 Introduction The ASI-4 is a 2 1/4 sunlight readable instrument that provides a wide range airspeed indication in both digital and analog

More information

VT 210. Thermo-Hygrometer-Anemometer

VT 210. Thermo-Hygrometer-Anemometer VT 210 Thermo-Hygrometer-Anemometer Table of contents 1. Presentation...6 1.1. Instrument description...6 1.2. Key description...6 1.3. Remove battery...7 2. Connections of the VT210...8 2.1. Main features...8

More information

Anemometer SD Card Datalogger. Instruction Manual

Anemometer SD Card Datalogger. Instruction Manual Anemometer SD Card Datalogger 850023 Instruction Manual 1 Anemometer SD Card Datalogger 850023 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not

More information

DIGITAL POCKET HEAT INDEX MONITORS USER S MANUAL

DIGITAL POCKET HEAT INDEX MONITORS USER S MANUAL DIGITAL POCKET HEAT INDEX MONITORS USER S MANUAL Please read this manual carefully and thoroughly before using this product. SAM800HI (Sports Model) SAM800IND (Industrial Model) 99 Washington Street Melrose,

More information

Supplied with. Calibration certificate. Anemometer VT 200

Supplied with. Calibration certificate. Anemometer VT 200 Supplied with Calibration certificate Anemometer VT 200 Table of contents 3 I Technical specifications...4 Technical features......4 Specifications......4 II Introduction......5 Description......5 Connections......6

More information

Key features... 3 How it works... 3 Specifications Powering the module... 5 Mounting the module... 5 Operation... 5

Key features... 3 How it works... 3 Specifications Powering the module... 5 Mounting the module... 5 Operation... 5 Key features... 3 How it works... 3 Specifications... 4 Powering the module... 5 Mounting the module... 5 Operation... 5 Connect... 10 Device... 11 Device section... 11 Settings section... 11 FAI version...

More information

Key features... 4 Power supply... 4 Controls... 5 USB Connector... 5 SD card reader audio jack Thermal assistant...

Key features... 4 Power supply... 4 Controls... 5 USB Connector... 5 SD card reader audio jack Thermal assistant... Key features... 4 Power supply... 4 Controls... 5 USB Connector... 5 SD card reader... 5 3.5 audio jack... 5 Thermal assistant... 7 Task... 9 New... 9 Load... 10 Save... 10 Setup... 10 Start... 10 Task...

More information

Supplied with. Calibration certificate. TM 200 Thermometer

Supplied with. Calibration certificate. TM 200 Thermometer Supplied with Calibration certificate TM 200 Thermometer Table of contents 3 I Technical specifications...4 Technical features...4 Specifications...4 II Introduction...5 Description...5 Connections...6

More information

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL USER'S GUIDE BARD-LINK TM LC1000-100/LC1500-100 SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead,

More information

Supplied with. Calibration certificate. HD 200 Hygrometer

Supplied with. Calibration certificate. HD 200 Hygrometer Supplied with Calibration certificate HD 200 Hygrometer Table of contents 3 I Technical specifications...4 Technical features......4 Specifications......4 II Introduction......5 Description......5 Connections......6

More information

MAC3 Wind Speed Alarm & Controller. Installation Instructions

MAC3 Wind Speed Alarm & Controller. Installation Instructions MAC3 Wind Speed Alarm & Controller Installation Instructions Table of Contents Overview... 3 Installation... 3 Optional Equipment... 10 Dual Sensor Operation... 10 Other Optional Equipment... 10 Operation

More information

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Operator s Manual. Morbark Integrated Control System Woodhog Series Model 2600

Operator s Manual. Morbark Integrated Control System Woodhog Series Model 2600 Operator s Manual Morbark Integrated Control System Woodhog Series Model 2600 Contents Introduction 4 Parts Identification 6 Display Module Display Pages 9 Main Page 11 Engine Information Page 12 Hydraulic

More information

actoolsupply.com MP 200 Manometer Calibration certificate Supplied with actoolsupply.com

actoolsupply.com MP 200 Manometer Calibration certificate Supplied with actoolsupply.com Supplied with Calibration certificate MP 200 Manometer Kimo MP 200 P Thermo Anemometer Manometer Kimo MP 200 M Thermo Anemometer Manometer Kimo MP 200 G Thermo Anemometer Manometer Kimo MP 200 H Thermo

More information

MP 210. Thermo-Anemo-Manometer

MP 210. Thermo-Anemo-Manometer MP 210 Thermo-Anemo-Manometer Table of contents 1. Presentation...5 1.1 Instrument description...5 1.2 Keys description...5 1.3 Remove battery...6 2. Connections of the MP210...7 2.1 Main features...7

More information

EATON 5S 850/1200/1600

EATON 5S 850/1200/1600 www.eaton.com EATON 5S 850/1200/1600 Installation and user manual Packaging EATON 5S 1 2 3 5 Caution! l Before installing the Eaton 5S, read the booklet 3 containing the safety instructions to be respected.

More information

CYCLOPS TORNADO OSD V1.0 manual

CYCLOPS TORNADO OSD V1.0 manual CYCLOPS TORNADO OSD V1.0 manual Thanks for buying and using CYCLOPS OSD series products, please read this manual carefully before use. Installation of connections Important: select Jumper instructions:

More information

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: Fax:

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: Fax: Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: +61 7 41 553048 Fax: +61 7 41 553049 e-mail: support@microair.com.au About This Document This manual describes the various

More information

PRO ESC - LCD PROGRAM CARD USER MANUAL. The Fantom FR-10 PRO LCD Program Card only applies to the FR-10 PRO 1:10 scale, 2S, 160A brushless ESC.

PRO ESC - LCD PROGRAM CARD USER MANUAL. The Fantom FR-10 PRO LCD Program Card only applies to the FR-10 PRO 1:10 scale, 2S, 160A brushless ESC. PRO ESC - LCD PROGRAM CARD USER MANUAL The Fantom FR-10 PRO LCD Program Card only applies to the FR-10 PRO 1:10 scale, 2S, 160A brushless ESC. The LCD Program Card can be used in two ways as follows: 1.

More information

Introduction CLASS 1 LED PRODUCT

Introduction CLASS 1 LED PRODUCT Introduction Thank you for purchasing a set of FlightLights, a high performance LED system for model aircraft designed and manufactured by BrainCube Aeromodels Ltd. This manual will describe how to safely

More information

Clipsal HomeMinder Home Automation System

Clipsal HomeMinder Home Automation System Clipsal HomeMinder Home Automation System Part A Release 1.0.0 4 June 2000 Copyright 2000 Clipsal Integrated Systems Preface Congratulations on your purchase of HomeMinder. You now own a powerful and

More information

MTP INSTRUCTION MANUAL

MTP INSTRUCTION MANUAL MTP INSTRUCTION MANUAL Wireless Electricity Monitor Model MTP-3100 MTP Instruments Inc. Table of Content 1. Introduction Page 1 2. Safety and Maintenance Information Page 1 3. Features / Specifications

More information

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications. TITAN S8 Portable Data Acquisition Logger PRODUCT USER GUIDE To view the full MadgeTech product line, visit our website at madgetech.com. TABLE OF CONTENTS 2 Product Overview 5 User Interface 14 Logging

More information

Differential pressure measuring instrument

Differential pressure measuring instrument Differential pressure measuring instrument testo 526 Pressure measurement for all pressure ranges Temperature-compensated differential pressure sensor 0 to 2000 in instrument Additional 2 probe inputs

More information

HOME SECURITY KIT. USER MANUAL SMART PROTECTION WITH THE ALL-IN-ONE SOLUTION. SMART WINDOW SENSOR SMART POWER SOCKET SMART MOTION SENSOR SMART IP CAM

HOME SECURITY KIT. USER MANUAL SMART PROTECTION WITH THE ALL-IN-ONE SOLUTION. SMART WINDOW SENSOR SMART POWER SOCKET SMART MOTION SENSOR SMART IP CAM HOME SECURITY KIT. SMART PROTECTION WITH THE ALL-IN-ONE SOLUTION. SMART WINDOW SENSOR SMART POWER SOCKET SMART IP CAM SMART MOTION SENSOR USER MANUAL SL-900100/900111 HOME SECURITY KIT A/B SHORT INSTRUCTION

More information

SR200 GPS SPORTS WATCH. Keeping you one step ahead. User manual

SR200 GPS SPORTS WATCH. Keeping you one step ahead. User manual SR200 GPS SPORTS WATCH Keeping you one step ahead User manual Congratulations on purchasing your Snooper RUN SR200 Your new Snooper RUN SR200 is packed with loads of great features. It uses the latest

More information

ThermoSecure medical equipment GmbH

ThermoSecure medical equipment GmbH ThermoSecure medical equipment GmbH Thermosecure GmbH. Richmodstr 6 D-50667 Cologne Germany Tel:+ 49(0)2203 103960 Fax:+ 49(0)2203 104385 E-mail: info@thermosecure.de Manual for active thermosystems 1.1.1

More information

HOBO Temp/RH 2.5% Data Logger (UX ) Manual

HOBO Temp/RH 2.5% Data Logger (UX ) Manual HOBO Temp/RH 2.5% Data Logger (UX100-011) Manual The HOBO Temp/RH data logger records temperature and relative humidity (within 2.5% accuracy) in indoor environments with its integrated sensors. Using

More information

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen.

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen. User Manual Quick Start... 3 HOME... 4 SIMPLE TIMER... 4 AIR CON... 5 ZONES... 6 PROGRAMS... 7 HELP... 11 SETTINGS... 12 MyZone - (optional feature)... 15 Constant Zones... 17 Android Tablet... 18 Smart

More information

Programming and user guide

Programming and user guide Programming and user guide CareAssist 68100/01 D6707281B Introduction CareAssist is designed to support local carers to deliver high quality, non-intrusive care. It is extremely easy to use, portable device

More information

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION Revised Last Revised by Alex Messner This page was intentionally left blank. Table of Contents 1 Overview... 2 2 User Interface... 3 2.1 LEDs... 3 2.2 Buttons...

More information

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description. SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming

More information

TITAN S8. Portable Data Acquisition Logger. Product User Guide

TITAN S8. Portable Data Acquisition Logger. Product User Guide TITAN S8 Portable Data Acquisition Logger Product User Guide Table of Contents 2 General Features... 3 Device Overview... 3 External Features... 3 Device Orientation... 4 Device Inputs... 5 Sensor Types

More information

Loup Electronics Planter Monitor LPM II. User Guide

Loup Electronics Planter Monitor LPM II. User Guide Loup Electronics Planter Monitor LPM II User Guide TABLE OF CONTENTS 1. I TRODUCTIO...4 2. LIQUID CRYSTAL DISPLAYS...8 2.1 UPPER LCD...8 2.2 LOWER LCD...9 3. OPERATI G SPECIFICATIO...10 3.1 OPERATING MODES...10

More information

PT712-EI FOR FLOOR HEATING DIGITAL THERMOSTAT

PT712-EI FOR FLOOR HEATING DIGITAL THERMOSTAT DIGITAL THERMOSTAT PT712-EI FOR FLOOR HEATING including external sensor backup in case of voltage failure > 100 hours direct installation on junction box well-arranged backlit display VENUS switch design

More information

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51 Dryer M720 Programming and Operation Manual July 15, 2015 Revision 1.51 Contents 1 Important Safety Information 1 1.1 FOR YOUR SAFETY - CAUTION!............................. 1 2 Control Overview 2 2.1

More information

Blaze ASI-5. Introduction. 1 Features. Airspeed Indicator (ASI) Operating Manual English 1.00

Blaze ASI-5. Introduction. 1 Features. Airspeed Indicator (ASI) Operating Manual English 1.00 Blaze ASI-5 Airspeed Indicator (ASI) Operating Manual English 1.00 Introduction The ASI-5 is a 3 1/8 sunlight readable instrument that provides a wide range airspeed indication in both digital and analog

More information

HOBO External Temp/RH Data Logger (UX ) Manual

HOBO External Temp/RH Data Logger (UX ) Manual HOBO External Temp/RH Data Logger (UX100-023) Manual The HOBO External Temp/RH data logger records temperature and relative humidity in an indoor environment with its external sensor. Using HOBOware, you

More information

AQ 200 AQ 200 Air Quality

AQ 200 AQ 200 Air Quality AQ 200 AQ 200 Air Quality Table of contents 3 I Technical specifications...4 Technical features...4 Specifications...4 II Introduction...5 Description...5 Connections...6 III Browsing...7 IV Menus...8

More information

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03

More information

LCC-S Configuration software for transmitters

LCC-S Configuration software for transmitters LCC-S Configuration software for transmitters Table of contents 1. Introduction...5 2. Software installation...5 2.1. Minimum system requirement...5 2.2. Installing the software...5 3. Start with the

More information

Orchestra Orchestra reference

Orchestra Orchestra reference Orchestra Orchestra reference Integrated amplifier Owner's Manual Table of contents Introduction Warning Unpacking and checking Description Installation instruction Tube position How to match your amplifier

More information

FM100 Fume hood monitoring system according to EN 14175

FM100 Fume hood monitoring system according to EN 14175 Functional description Performance features Functional description For use as a monitoring and alarm system for exhaust fl ows in various applications, such as fume hoods, safety cabinets and other extraction

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

K44 Code lock. Technical manual

K44 Code lock. Technical manual K44 Code lock GB Technical manual Copyright 2002 Bewator AB, Solna, Sweden. Material from the K44 Technical manual may only be copied with the consent in writing of Bewator. Bewator reserves the right

More information

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) Product Information DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Phone +49.2355.806-0 Fax +49.2355.806-189 E-Mail:

More information

Peristaltic Cased Tube Pump

Peristaltic Cased Tube Pump Peristaltic Cased Tube Pump Selectable Output Control Functionality and Setup Version 1.0v-11/2016 Print-No. 01 Table of Contents 1. Introduction 2. Powering the Input/Output Port 2.1 Wiring for Local

More information

TOUCH SCREEN WEATHER STATION (WIND AND AIR PRESSURE) WH-1080PC. Operation Manual

TOUCH SCREEN WEATHER STATION (WIND AND AIR PRESSURE) WH-1080PC. Operation Manual TOUCH SCREEN WEATHER STATION (WIND AND AIR PRESSURE) WH-1080PC Operation Manual About this manual Thank you and congratulations on selecting this professional weather station! We are positive you will

More information

Thank you for purchasing the WheelWitness HD PRO Dash Cam!

Thank you for purchasing the WheelWitness HD PRO Dash Cam! Owner s Manual Thank you for purchasing the WheelWitness HD PRO Dash Cam! We are always here to help so please do not hesitate to let us know any questions or concerns you may have! Your 100% satisfaction

More information

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer SD card real time datalogger + Type K/J thermometer ANEMOMETER Model : AM-4207SD Your purchase of this ANEMOMETER with SD CARD DATALOGGER marks a step forward for you into the field of precision measurement.

More information

USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n USER MANUAL Mobeye WaterGuard-FS Float sensor CM2300FS SW version 5.n CONTENT 1. General description 4 2. Getting started 5 2.1 Insert a SIM card 5 2.2 Connect a sensor to the input 6 2.3 Insert the batteries

More information

ARTiPRO. User Manual. (Model 910 & 920)

ARTiPRO. User Manual.   (Model 910 & 920) ARTiPRO User Manual (Model 910 & 920) www.rtihub.com Main Keys & Interfaces 1. Main LCD display 2. / button 1 2 3 4 5 8 6 3. button 4. / button 5. Power & Alert LED 6.

More information

TA400 OPERATING MANUAL DYNAMIC PRESSURE ANEMOMETER TRT-BA-TA400-TC-002-EN

TA400 OPERATING MANUAL DYNAMIC PRESSURE ANEMOMETER TRT-BA-TA400-TC-002-EN TA400 EN OPERATING MANUAL DYNAMIC PRESSURE ANEMOMETER TRT-BA-TA400-TC-002-EN Table of contents Notes regarding the operating manual... 1 Safety... 2 Information about the device... 3 Technical data...

More information

GENERAL DESCRIPTION... 1 INSTALLATION... 2 CONNECTIONS... 3 OVERVIEW... 6 AREA & SPEED METER SETUP (WIZARD)... 9

GENERAL DESCRIPTION... 1 INSTALLATION... 2 CONNECTIONS... 3 OVERVIEW... 6 AREA & SPEED METER SETUP (WIZARD)... 9 TABLE OF CONTENTS For Serial Numbers 30007000-7999 GENERAL DESCRIPTION... 1 INSTALLATION... 2 CONNECTIONS... 3 OVERVIEW... 6 AREA & SPEED METER SETUP (WIZARD)... 9 AREA & SPEED METER USING GPS SETUP (WIZARD)...

More information

The BOM [Broadcasting Outer Module]

The BOM [Broadcasting Outer Module] Avionics Reimagined The BOM [Broadcasting Outer Module] The first and only ALL-IN-ONE AVIONICS SUITE Distributed by: Adams Aviation Supply Co Ltd mail@adamsaviation.com www.adamsaviation.com BOM (Broadcasting

More information

GAMMA instabus Application Program Description. November CO Touch-Panel

GAMMA instabus Application Program Description. November CO Touch-Panel Use of the application program Product family: Product type: Manufacturer: Name: Order no.: Name: Order no.: Display Display units Siemens UP 588/2 Colour Touch Panel (AC 230 V) 5WG 588-2AB2 UP 588/22

More information

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket echnical data sheet Damper actuator for Modbus for adjusting air dampers in ventilation and air conditioning systems in buildings orque 5 Nm Nominal voltage AC/DC 4V Communication via Modbus RU (RS-485)

More information

application software

application software application software application software RF input product Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices 8565 52 xx 8565 62

More information

Technical data. Safety notes. Product features

Technical data. Safety notes. Product features Technical data sheet BKN230-MOD 11-00002.F Communication and power supply unit for motorised fire dampers Communication via RTU (RS-48) AC 230 V supply via Euro plug Power is supplied to the actuators

More information

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs INSTRUCTION MANUAL Model 421504 Dual Input RTD Thermometer Measures two temperatures simultaneously Dual RTD probe inputs Clock and Elapsed Timer functions Special functions include Data Hold, MIN/MAX/AVG,

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

Flytec Bluetooth Option

Flytec Bluetooth Option Option English Setup Bluetooth In order to use the Bluetooth/SMS option, the Bluetooth module must be installed and tested by Flytec or Bräuniger. With the BT module installed and the SMS feature unlocked

More information

RC T3000. Vario and navigation system. Manual version: 1.0. RC Electronic

RC T3000. Vario and navigation system. Manual version: 1.0. RC Electronic RC T3000 Vario and navigation system Manual version: 1.0 RC Electronic support@rc-electronics.org, http://www.rc-electronics.org Contents Introduction... 3 Power supply... 3 Controls... 3 USB Connector...

More information

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced

More information

Supplied with. Calibration certificate. TM 200 Thermometer

Supplied with. Calibration certificate. TM 200 Thermometer Supplied with Calibration certificate TM 200 Thermometer Table of contents 3 I Technical specifications...4 Technical features...4 Specifications...4 II Introduction...5 Description...5 Connections...6

More information

LED Dot Matrix Digital Clock. Instructions. Contents. v (5x7-1x6 Module)

LED Dot Matrix Digital Clock. Instructions. Contents. v (5x7-1x6 Module) LED Dot Matrix Digital Clock v1.0.2 (5x7-1x6 Module) Instructions Designer: Yan Zeyuan. China Website: E-mail: yanzeyuan@163.com Contents Attention... 2 Functional Features... 2 Technical Specifications..

More information

Installation and Operation Manual SPC1

Installation and Operation Manual SPC1 Installation and Operation Manual SPC1 BIA-SPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMP FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMP FLOAT CONNECTED TO PUMP 6-7 QUICK GUIDE

More information

Owner s Manual. Digital Player Addendum. For Heat Siphon Swimming Pool Heat Pumps

Owner s Manual. Digital Player Addendum. For Heat Siphon Swimming Pool Heat Pumps Made in Latrobe Since 1983 Pennsylvania U.S.A. Owner s Manual Digital Player Addendum For Heat Siphon Swimming Pool Heat Pumps Heating Only Models: Z250HP, Z375HP, Z575HP & Z700HP Z250HP50, Z375HP50, Z575HP50

More information

DSC programming for the Alexor and Impassa

DSC programming for the Alexor and Impassa DSC programming for the Alexor and Impassa THERE IS NO REASON TO BE IN ANY SECTION OF YOUR SYSTEM UNLESS IT IS ON THIS QUICK START GUIDE. If you do not see it here, please question if you should be doing

More information

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER Model : AM-4257SD Your purchase of this CUP ANEMOMETER marks a step forward for you into the field of precision measurement. Although this

More information

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions Product Identification BAPI s Touch Low Range Pressure Sensor with Attached Static Pressure Probe is an accurate, rugged and economical solution for measuring and reporting duct/building static pressure,

More information

DPL4000 Portable Low Range Dew Point Analyzer

DPL4000 Portable Low Range Dew Point Analyzer OPERATIONS MANUAL DPL4000 Portable Low Range Dew Point Analyzer 7205 Edington Drive / Cincinnati, OH 45249 / Tel (513) 772-0060 / Fax (513) 772-9466 Page #1 of 16 M4581 DPL4000 Product Description: This

More information

Differential pressure

Differential pressure Differential pressure measuring instrument 521 Precise Pitot tube measurement Temperature-compensated differential pressure sensor in instrument Additional 2 probe inputs for the connection of further

More information

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: Fax:

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: Fax: Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: +61 7 41 553048 Fax: +61 7 41 553049 e-mail: support@microair.com.au About This Document This manual describes the various

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

FC-DIN DIN-Rail Mount Fan Speed Controller

FC-DIN DIN-Rail Mount Fan Speed Controller Page 1 of 7 FC-DIN DIN-Rail Mount Fan Speed Controller Features: Benefits: Volume or velocity reduction Suitable for supply & extract systems Minimum and maximum speed adjustment DIN-Rail mountable Configurable

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

Wireless Data Logger System

Wireless Data Logger System RTR-57U Wireless Data Logger System Collect, Manage and Monitor Your Valuable Data via Wireless Communication USB ion With sensor adaptor connected RS-232C ion to Computer to Network Image created for

More information

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page

More information