Issue 03/2013. The Electronic Load
|
|
- Kathlyn Cox
- 6 years ago
- Views:
Transcription
1 Issue 03/2013
2 ZS Electronic Loads, PL Series Interface overview RS-232 USB / GPIB LAN System bus Analog X Analog isolated / X Standard ption / not available PL506 PL1006 Voltage Current Resistance 3) Model Continuous Shorttime Rise and fall Housing Connections 4) (order number) power power 1) time 2) PL W 900 W 60 V 50 A 75 µs 0.1 Ω... ½19, 2HU FK 8 PL506 SC5 5) 300 W 300 W 60 V 5 A 75 µs 1 Ω... ½19, 2 HU PK 4 PL W 900 W 120 V 20 A 75 µs 0.2 Ω... ½19, 2 HU PK 4 PL W 900 W 240 V 10 A 75 µs 0.5 Ω... ½19,2 HU SB 4 PL W 600 W 400 V 8 A 75 µs 1.5 Ω... ½19, 2 HU SB 4 PL W 1800 W 60 V 100 A 75 µs 0.05 Ω... 19, 2 HU FK 8 PL1006 SC10 5) 600 W 600 W 60 V 10 A 75 µs 0.5 Ω... 19, 2 HU PK 4 PL W 1800 W 120 V 50 A 75 µs 0.1 Ω... 19, 2 HU FK 8 PL W 1800 W 240 V 20 A 75 µs 0.3 Ω... 19, 2 HU SB 4 PL W 1200 W 400 V 16 A 75 µs 1 Ω... 19, 2 HU SB 4 PL W 2700 W 60 V 150 A 75 µs 0.04 Ω... 19, 2 HU FK 8 PL1506 SC15 5) 900 W 900 W 60 V 15A 75 µs 0.4 Ω... 19, 2 HU PK 4 PL W 2700 W 120 V 80 A 75 µs 0.06 Ω... 19, 2 HU FK 8 PL W 2700 W 240 V 30 A 75 µs 0.2 Ω... 19, 2 HU SB 4 PL W 1800 W 400 V 25 A 75 µs 0.5 Ω... 19, 2 HU SB 4 1) The possible short time power depends on the temperature of the output stage, i.e. on the previous load. 2) Rise and fall times are defined from % and % of the maximum current. (Constant current operation, tolerance +/- 20 %). 3) is achieved in the context of reproducibility for resistance operation. 4) SB 4: Protected laboratory socket 4 mm PK 4: Pole terminal for 4 mm laboratory jack FK 8: Flat copper rail with M8 screw 5) Devices with reduced setting range 1HU = 1 height unit = mm perating Modes Dynamic peration Protective Devices verload Capacity The devices have constantcurrent and constant-resistance operating modes in both static and dynamic operation. If fitted with an RS-232 or GPIB interface, softwarecontrolled constant power control is possible. The manual setting of the load values takes place via two precise ten-turn potentio-meters. Switch from value A to value B by a keystroke. In dynamic mode the inbuilt modulator performs the switch between the setpoints A and B. For each load level it is possible to set a corresponding pulse duration of 0.5 ms milliseconds. In addition, pulse-pause ratios can be varied within broad time range. Switching between the two load levels can also be via the analogue I/ interface at all levels between 3 V and 30 V. ver-current protection ver-power protection ver-temperature protection ver-voltage protection Reverse polarity protection Protection of the GND lines at the Analog I/ interface If a protected value is exceeded the respective display flashes. The type spectrum comprises three power classes with 500 W, 1000 W and 1500 W continuous load capacity. Depending on the model the devices have temporary overload capacity. The level and duration of the possible overload depends on the operating temperature of the power stage. The device can also be used for significantly higher power tasks. 8
3 ZS Analog I/ Interface The Analog I/ Interface also Standard Analog I/ Interface with V level for: has the following logical inputs and outputs: Input voltage Load current Power consumption Nominal current Master-Slave circuit verload status for the overload display Trigger output during dynamic operation Trigger input for external control of the dynamic load change The control of the load current can be via an analog signal with optionally V or V. Control input for battery test Control Input for external load activation Sense terminals (for 60V and 120 V models) Interfaces RS-232 Interface Requires PL01 or PL02. Factory Calibration ptional interfaces are an RS- 232 and a combined GPIB + RS- 232 interface. The interfaces enable all settings functions including comprehensive dynamic settings incl. programmable rise and fall times. There is also a measurement function for input voltage and load current. All interfaces are electrically isolated from the load input to prevent earth loops forming with the test structures. Programming takes place in SCPI syntax. (ption PL01) The RS-232 interface is the most economical option for controlling devices by PC. It also includes the system bus interface which allows multi-channel systems to be constructed. GPIB + RS-232 interfaces (ption PL02) Combined GPIB + RS-232 interface + system bus interface External LAN-RS232 Adapter (ption PL04) Enables the device to be controlled via LAN interface. Tools The H&H Homepage has a program library for Windows with the following applications: Load control via PC Programming of custom load profiles Recording of current limitation characteristics Endurance test with memory function for voltage and current Battery testing with recording of discharge curves LabVIEW driver Certificate (ption FCC-PLxx) A Factory Calibration Certificate (FCC) can be supplied with the devices. The FCC meets the requirements according to DIN EN IS 9000ff. This calibration certificate documents the traceability to national standards to illustrate the physical device in accordance with the inter-national System of Units (SI). The recommended calibration interval is 1 year. Configuration of a Multichannel System For control of additional devices via the GPIB or RS-232 interface of the primary device, any number of devices can be connected via the system bus interface (ption PL01 in all other devices). Despite the shared interface, the devices are electrically isolated from one another and can be operated with potential differences of up to 125 V. 9
4 perating temperature ZS Technical Data PL Series Accuracy of manual setting, no preset function Current ±0.4 % ±0.05 % Resistance (at 5% to 100% of the voltage range) ±5 % ±0.5 % of current range Accuracy of manual setting, with preset function Current Accuracy of display of the preset value ±0.6 % ±0.05 % of the measured value (actual value) Voltage ±0.2 % ±0.05 % ±1 digit Current ±0.4 % ±0.05 % ±1 digit Accuracy of analog control V / V for current setting Current 10 V 5 V ±0.5 % ±1.5 % Input resistance of analog inputs 10 kω/20 kω at 5 V/10 V GND max. ±2 V with respect to negative load input Accuracy of analog measurement outputs V for current, voltage, power of analog signal of actual value ±0.2 % ±0.4 % offset voltage Voltage ±0.2 % ±20 mv Current ±0.3 % ±20 mv Power ±5 % ±30 mv Reference voltage 10.5 V Load capacity: minimal 2 kω ±4 % Accuracy of setting Programming via data interface (ption PL01 or PL02) Current ±0.4 % ±0.05 % Resistance (at 5 % to 100 % of the voltage range) Resolution setting 12 Bit ±5 % ±0.5 % of current range Accuracy of measurement, read out via data interface of the measured value (actual value) Voltage ±0.2 % ±0.06 % Current ±0.5 % ±0.12 % Resolution Sampling rate 13 bit Control via Analog I/ interface Status outputs (open collector 30 V) External control functions (Level 3 V V) Dynamics 300 ms, non-triggering verload Trigger output at dynamic load Load switching off - on Battery test off - on Trigger input for switching dynamic load level two load levels in I and R mode, two separately adjustable times External triggering of load level switching also possible Input Input resistance Input capacity Parallel operation Input voltage Minimum voltage Permissible operating voltage Protective devices Connections: Load input: Sense: Continuous power >50 kω when load input is off Approx. 2 µf / 500 W Up to 5 units in Master-Slave mode (hardware-controlled) Min. 1.4 V for max. current including linear derating of current with respect to 0 V Negative load input - housing 125 V DC ver-voltage up to 120 % of rated voltage, over-current, over-power, over-temperature, reverse polarity up to rated current, transient protection, display by flashing of current and/or voltage display, under-voltage display (if input voltage is too low for the set load) up to 120 V: available on I/ interface from 240 V: unavailable (where TA = 21 C) Derating -1.2 % / C for TA > 21 C verload capacity Time range for internal modulator Accuracy of the time setting Battery test Adjustable cut-off voltage Presetting function Current mode Resistance mode perating conditions Cooling 1 ms ms (2 Hz... 1 khz) ±10 % ± 0.2 ms the load is reduced to 0 on reaching the cut-off voltage (I/V mode, R/V mode) Direct display of load current Display of expected load current with applied input voltage 5 C C 2-stage air-cooling Noise PL5XX PL10XX PL15XX 55 dba 59 dba 60 dba Supply voltage Power consumption Dimensions W x B x D (mm) weight Colour Front panel, back panel side panels, top 115/230 V~ ±10 %, switchable Hz PL5XX PL10XX PL15XX max. 30 VA max. 50 VA max. 60 VA PL5XX PL10XX PL15XX 222 x 88 x x 88 x x 88 x kg 12 kg 16 kg RAL7032 (pebble grey) RAL7037 (stone grey) Electrical safety DIN EN 61010: EMC, CE marking DIN EN : DIN EN : DIN EN : mounting kits for models order number 1 PL5XX ES PL PL5XX ES PL05-2 PL10XX or PL15XX ES PL2 Warranty 2 years Subject to technical modifications 10
5 Hoecherl & Hackl GmbH Industriestr Konzell Germany Tel.: / Fax.: /
Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition
Electronic Multi-channel Load PMLA 150 W / 600 W 40 V up to 240 V 1 A up to 120 A Preliminary Edition Functionality Interface Overview Master RS-232 X CAN O USB X Analog O LAN X Analog isoliert / GPIB
More information200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL
200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant
More information3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A
3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A 2 Electronic Energy Recycling Load ERI Series Syntax Interface Overview RS-232 USB LAN GPIB O CAN Analog Analog isolated O Standard O Option /not available
More informationFeatures. Description. Applications
Description Features The electronic loads of the ZSAC series are optimized for the practical use in laboratories, manufacturing and quality control. Power: Voltage: Current: 400W... 12600W 260V... 440V
More informationREGENERATIVE LOAD ERI SERIES
Electronic DC Loads REGENERATIVE LOAD ERI SERIES ERI Series Brief Profile The electronic loads of the ERI series feed the absorbed energy back into the local supply network. This protects the environment
More informationLOW POWER PLA SERIES. Interfaces. Electronic DC Loads
Electronic DC Loads LOW POWER PLA SERIES The electronic loads of PLA series combine the classic design of large, easy-to-read displays with modern interfaces and a wide range of functions. The devices
More informationREGENERATIVE LOAD ERI SERIES
Electronic DC Loads REGENERATIVE LOAD ERI SERIES The electronic loads of the ERI series feed the absorbed energy back into the local supply network. This protects the environment and reduces electricity
More informationSingle-output and dual-output power supplies. TOE 8840 up to 160 W TOE 8850 up to 320 W. In-phase regulation
Single-output and dual-output power supplies up to 160 W up to 320 W In-phase regulation TOE 8852 A proven concept has been used for the new, systemcompatible single-output and dual-output power supplies
More informationProgrammable DC Power Supplies XLN Series
Data Sheet New Family of High Density System Power Supplies The B&K Precision XLN series are programmable, single-output DC power supplies, that provide clean power up to 1560 watts in a compact 1U rackmountable
More informationSeries Watt DC Power Supplies
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Series 2268 850-Watt DC Power Supplies Specifications SPECIFICATION CONDITIONS This document contains
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationPROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)
Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load) 3-349-632-03 1/5.11 Generator voltage up to 1000 V DC, current up to 20 A DC Measurement of
More informationSSP-KONSTANTER, Series 62 N and Series 64 N Computer Controlled Laboratory Power Supplies
Computer Controlled Laboratory Supplies 3-349-078-03 2/8.04 Series 62 N: 500 W, 1000 W output power Series 64 N: 2000 W, 3000 W output power Measuring functions for voltage, current and power with extreme
More informationKONSTANTER SPL Series Programmable Electronic Load
3-349-701-03 2/11.14 4 operating modes: constant current, constant voltage, constant load, constant power High speed sequence and transient measurement, short-circuit proof, battery discharging and other
More informationLAB-HPP COMPACT HIGH POWER DC SOURCES
ELECTRONIC TEST & POWER SYSTEMS LAB-HPP COMPACT HIGH POWER DC SOURCES POSITIVE PROBLEM SOLVING The LAB-HPP family can be used as a stand alone power supply or as component in a wider automated test system.
More informationProgrammable Digital Controlled DC Power Supplies
Smart choice for power Programmable Digital Controlled DC Power Supplies High Power and Performance for: ATE Bulk Power Production Test OEM Burn-in www.xantrex.com XDC Series Digital Power Supplies 6 kw
More informationR&S HMC804x Power Supply 100 W and 1, 2 or 3 Channels
R&S HMC804x Power Supply 100 W and 1, 2 or 3 Channels Test & Measurement Product Brochure 01.03 Total output power All models: 100 W Output current per channel HMC8041: max. 10 A HMC8042: max. 5 A HMC8043:
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet
More informationDIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:
DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationFan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in prom design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationEA-EL 3000, EA-EL9000, EA-EL 9000 HP 400W W ELECTRONIC DC LOADS
EA-EL 3000, EA-EL9000, EA-EL 9000 HP 400W - 7200W ELECTRONIC DC LOADS Power ratings: 0...400W up to 0...7200W Cabinets with higher power upon request Input voltages: 0...80V, 0...160V, 0...400V, 0...750V
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:
More informationTHURLBY THANDAR INSTRUMENTS. PL & PL-P Series. Laboratory Power Supplies. Standard and Programmable models, 35 watts to 240 watts
THURLBY THANDAR INSTRUMENTS PL & PL-P Series Laboratory Power Supplies Standard and Programmable models, 35 watts to 240 watts Thurlby Thandar PL series the Premier range of laboratory power supplies Precision
More informationProgrammable DC power supplies
3-Year Warranty Series 2260B 360W, 720W, and 1080W versions with voltages up to 800V and currents up to 108A Programmable voltage or current rise and fall times prevents damage to low impedance loads from
More informationLXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W
Characteristics motion servo drive - Lexium 28 - single and three phase 200...230 V - 750 W Main Range of product Lexium 28 Product or component type Device short name Format of the drive Line current
More informationSYSKON P1500 Computer Controlled Laboratory Power Supply
3-349-437-03 4/4.08 Series SYSKON P1500: 1500 W output power Measuring functions for voltage, current and power with threshold memory (min & max values) Minimal residual ripple and short response times
More informationMINI MCR-SL-UI-2I(-SP)(-NC)
Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the
More information360W and 720W Programmable DC Power Supplies
3-Year Warranty Series 2260B 360W and 720W versions with voltage up to 80V and current up to 72A Combine power supplies in serial and parallel combinations to expand voltage and current outputs up to 160V
More informationProgrammable Dual-Range DC Power Supplies 9170 & 9180 series
Data Sheet Programmable Dual-Range DC Power Supplies Outstanding performance combined with unique features The 9170/9180 series programmable DC power supplies offer industry leading performance, designed
More informationATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationATV12H018M2 variable speed drive ATV kW hp V - 1ph
Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 200..240V - 1ph Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationAdvant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System
Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.
More informationNI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O
DATASHEET NI REM-11115 Analog Output Module for Remote I/O Four voltage output ranges to choose from (0 V to 10V, ±10V, 0 V to 5 V, and ±5V) Two current output ranges to choose from (0 ma to 20mA, 4 ma
More informationATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate
Characteristics variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - on base plate Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationSorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply
Sorensen DLM 600 Series Half Rack Programmable DC Power Supply High Power Density: 600 watts in 1U (1.75 inches) high, half rack (8.5 inches) wide; no top or bottom clearance spacing required. Near Linear
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationAIM & THURLBY THANDAR INSTRUMENTS
AIM & THURLBY THANDAR INSTRUMENTS MX100T & MX100TP Triple output dc power supplies - 315 watts Three full performance outputs of equal power Multiple-ranges, up to 70V and up to 6A Ultra-compact size for
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationSeries MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES
FEATURES 2kW output power Output voltages from 20V to 300V High Packing Density - 2kW in 1U Parallel/series operation Stackable, cooling is front to rear Active Power Factor Correction Custom options available
More informationAIM & THURLBY THANDAR INSTRUMENTS
AIM & THURLBY THANDAR INSTRUMENTS MX100T & MX100TP Triple output dc power supplies - 315 watts Three full performance outputs of equal power Multiple-ranges, up to 70V and up to 6A Ultra-compact size for
More informationOHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L
AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power
More informationAB Axis Industries. Use
AB Axis Industries PULSE ADAPTER ENCO PULSE The ENCO PULSE pulse adapter acquires and handles the pulses from consumption meters with pulse output and transmits the data to a network of AMR system. Use
More informationAbsolute Encoders Multiturn
The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow
More informationEfficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple
FEATURES Industrial Standard 2" X 1" Package Wide 2:1 Input Range Fully Regulated Output I/O Isolation 40VAC with Reinforced Insulation, rated for 300VAC Working Low Leakage Current < 5µA Operating Ambient
More informationPSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description
SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation
More informationEfficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %
FEATURES Smallest Encapsulated 10W Industrial Standard DIP16 Package Ultrawide 4:1 Input Voltage Range Fully Regulated Output Voltage I/O Isolation 1500VDC Operating Ambient Temp. Range 40 to 88 Low No
More informationProgrammable Power Supplies 188 W 384 W HMP Series
Programmable Power Supplies 188 W 384 W The 2, 3 or 4 Channels Key facts The four power supply units,, HMP4030 and HMP4040 from HAMEG Instruments offer you the choice between 2, 3 and 4 channels with a
More informationATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - on base plate Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
More informationPU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance
PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without
More informationATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink
Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application
More informationThis data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is
More informationTM221CE40T controller M IO transistor PNP Ethernet
Product data sheet Characteristics TM221CE40T controller M221 40 IO transistor PNP Ethernet Complementary Main Discrete I/O number 40 Number of I/O expansion module Supply voltage limits Inrush current
More informationATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)
Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 370 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application
More informationATV1200A kv kva
Characteristics medium voltage variable speed drive ATV1200-10 kv - 5000 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application
More informationATV1200A kv kva
Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 3500 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application
More informationPCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1
Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10
More informationPHOENIX CONTACT Features
Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase
More informationStrain Gage Measuring Amplifier GSV-3
Strain Gage Measuring Amplifier GS-3 Tel 03302 559 282, Fax: 03302 559 141, info@me-systeme.de, www.me-systeme.de 1 Strain Gage Measuring Amplifier GS-3 Description...4 Models...5 Measurement Resolution...5
More informationadjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance
Processor-based bargraph with digital display vertical or horizontal MB3 3-digit digital display -199 999 red display, optional green 30 dots bargraph display tricolour adjustment via factory default or
More informationNI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O
DATASHEET NI REM-11178 Digital Output Module for Remote I/O Short circuit and overload protection Drives up to 500 ma per channel (up to 8A per module) Spring-terminal connectors allow fast wiring without
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More informationTM221CE24R controller M IO relay Ethernet
Product data sheet Characteristics TM221CE24R controller M221 24 IO relay Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Inrush
More informationA2000 Multifunctional Power Meter
3-348-980-03 3/12.99 Capable of communications via Profibus-DP, LONWORKS interface or RS 485 interface (depending upon model) Measurement of current, voltage, active, reactive and apparent power, power
More informationRoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e
The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via
More informationISOMETER isoev425 with coupling device AGH420
with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device
More informationAPM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety
FEATURES Fully encapsulated Plastic Case 3 Mounting Versions: - PCB Mounting with Solder Pins - Chassis Mounting with Screw Terminals - DIN-Rail Mounting Package Dimension 88.9x63.5x30.0 mm (PCB Version)
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationNMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02
1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and
More informationTM221M16TG controller M IO transistor PNP spring
Characteristics controller M221 16 IO transistor PNP spring Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More informationFLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet
Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system
More informationSorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply
Sorensen DLM 600 Series Half Rack Programmable DC Power Supply high, half rack (8.5 inches) wide; no top or bottom clearance spacing required. rms, noise as low as 15mV p-p. 0-5kΩ. 375 600 W 5 300 V 2
More informationWP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports
Optimized I/O Combi module 2 serial COM-ports 16 digital outputs/26 digital inputs/4 high-speed counter inputs 4 analog outputs/8 analog inputs/8 PT100 inputs/2 thermistor inputs Compact design Improved
More informationTechnical data. Your advantages
Technical data Nominal torque: 10.000 Nm to 25.000 Nm, bidirectional Customer-specific calibration upon request Rotational speed: 8.000 rpm Accuracy: ±0,5 % Temperature range: -30 C to +85 C Protection
More informationCommunications & Networking
is a type of field bus that is primarily intended to be used to control sensors and actuators. is a network system that is compatible with the IEC62026 standard. A master device can communicate with slave
More information5VPxA SERIES HIGH POWER DC LOADS
5VP Series DC LOADS Key features: Models from 5kW to 60kW Master/Slave Parallel Operation of up to Eight 5VP Loads for Higher Power Needs up to 480kW Voltage Ranges, 60V, 600V, 1000Vdc or 1250Vdc Current
More informationAIAS. Technical description
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -
More informationIndustrial Power Supplies
75-600 Watt Features Switch mode power supplies for DIN-rail mounting 4 power ranges with 3, 6, 12 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise EMI complies
More informationAS-i Safety Analog Input Module, IP20
2 safe inputs in one module: 4... 20 ma or 0... 10 V or Pt100 or thermocouple (type J / K / N / R / S) Applications up to category 4/PLe/SIL 3 (figure similar) The AS-i Safety Input Module for analog inputs
More informationElectronic timer CT-AHD.22
2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationData Sheet Rev DALLIS Serial Data
Lawo AG, Germany Phone: +9 00-0 Web: www.lawo.de Data Sheet Rev. 00-0-0 DALLIS Serial Data Port serial multi-format data converter 9/ Serial Data bidirectional data Ports, data rates up to 00 bps Supports
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationATV320U04N4C variable speed drive ATV kW V - 3 phase - compact
Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product
More informationMINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:
Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration
More informationVariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.
Universal Isolation Amplifiers The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply. The Housing At a width of just 12.5 mm, the modular housing with pluggable
More informationProgrammable Dual-Range DC Power Supplies 9170B & 9180B Series
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Data sheet Programmable Dual-Range DC Power Supplies 9170B & 9180B Series Outstanding performance combined
More informationDINALOG A 144 x 36 A1400 Light-Strip Indicator
DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet GM24A-MOD Communicative damper actuator for adjusting dampers in technical building installations orque motor 40 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion
More informationIndustrial Power Supplies
50-600 Watt Features Switch mode power supplies for DIN-rail mounting 6 power ranges with 2, 3, 6, 12, 20 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise
More informationVersaPoint I/O Module
Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm
More information4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus
4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output
More informationATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink
Product datasheet Characteristics ATV12H075M3 variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - with heat sink Complementary Main Range of product Altivar 12 Product or component type Product
More informationData sheet CC 03, Commander Compact (603-1CC21)
Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:
More informationABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011
Technical data 2CDC508136D0202 ABB i-bus KNX Product description The device is a modular installation device (MDRC) in Pro M design. It is intended for installation in distribution boards on 35 mm mounting
More information