MG - Supported Nortel/Avaya Media Gateway Controllers
|
|
- Liliana Adams
- 6 years ago
- Views:
Transcription
1 Published on Documentation ( Home > MG - Supported Nortel/Avaya Media Gateway Controllers MG - Supported Nortel/Avaya Media Gateway Controllers Only MGC card, MGXPEC card, Digital Line Cards (DLC) and Analog Line Cards (ALC) are allowed in the chassis or cabinet. The system will not be supported if there are any other cards present in the chassis or cabinet, e.g. Universal line card. Media Gateway Controller (MGC) MGC Loadware MGC loadware is contained on the MGCs compact flash. A UCx MGC pre-programmed compact flash containing the correct loadware must be purchased from E-Metrotel in order to be supported. Supported combination of DSP daughterboards The following marking is present on MGC circuit board for daughterboard placement. Page: 1
2 DSP daughterboard slot 1: D/B 1 SLOT 11 LOW OR HIGH DENSITY DSP daughterboard slot 2: D/B 2 SLOT 0 LOW DENSITY ONLY 32-port DSP daughterboard NTDW62xx is supported in DB SLOT 1 and SLOT2 96-port DSP daughterboard NTDW64xx is supported only in DB SLOT port DSP daughterboard NTDW78xx is supported only in DB SLOT 1 A minimum of 96 DSP ports is required for MGC to be supported with UCx MGC Serial connections Meridian Option 11C Cabinet (10 card, NTAK11) The serial cable connector can be found on the bottom left front of the Meridian Option 11C Cabinet (10 card, NTAK11)>. The NTBK48AA - DB9F to 3/DB25M - 3 Port SDI Cable for the Option 11 is required and plugs into the connector labelled SDI. Page: 2
3 MG 1000E Chassis (4 card, NTDU14) The serial cable connector can be found on the back of the MG 1000E Chassis (4 card, NTDU14). The NTBK48AA - DB9F to 3/DB25M - 3 Port SDI Cable for the Option 11 is required. Page: 3
4 MG 1010 Chassis (10 card, NTC310) The serial cable connectors can be found on the front of the MG 1010 Chassis (10 card, NTC310). The NTC325AAE6 serial cable kit is required. It contains a N RJ45 to DB25 (male) adapter which is intended to connect the MG1010 to a DCE device and two RJ45 to DB9 (female) N adapters which have an integrated null modem and are intended to connect the MG1010 to DTE devices. Page: 4
5 Media Gateway extended Peripheral Equipment Controller (MGXPEC) MGXPEC offers the option of converting a TDM based CS1000M system to CS1000E, an IP softswitch solution. MGXPEC transforms a single IPE shelf into 2 IPMG shelves and allows reuse of existing peripheral equipment. Please refer to the document CS1000M IPE Shelf Conversion to CS1000E IP Media Gateway (MG XPEC) Installation Method , March 10, 2010, Standard Issue: for instructions on converting CS1000M to CS1000E. MGXPEC Loadware A UCx MGC pre-programmed compact flash containing the correct loadware must be purchased from E-Metrotel in order to be supported. See Installing Compact Flashcards On An MGXPEC for instructions on how to replace the compact flash on your MGXPEC. Page: 5
6 MGXPEC Hardware NTDW20AAE6 MGXPEC (Media Gateway Extended Peripheral Equipment Controller) NTDW25AAE6 MGXPEC cable kit 2 new IO Panels 2 NTDW26ABE6 TTY Cables (Pin out same as MG1010) 8 Cat-5e ethernet cables 12 RJ45 couplers 1 Card Slot label Extended System Monitor (XSM) UCx does not support the XSM module (NTDW22AEE5) which connects to the Page: 6
7 MGXPEC through a serial connection. This has no affect on call processing or features. The MGXPEC supports all features supported by the MGC in a UCx system. MGXPEC Card Slots The MGXPEC card has to be seated in the Cont slot in the center of the shelf. Install new slot label on right side of shelf. The slots on right side are slots 0-7. MGXPEC DSP Daughterboards The MGXPEC card has two 96-port (NTDW64xx) DSP daughterboards mounted in slot 1 and slot 2 on both motherboard (MB) and daughterboard (DB) cards. The card slots assigned for DB-96 in DB slot 1 are 11, 12, 13. The card slots assigned for DB-96 in DB slot 2 are 8, 9, 10. MGXPEC Serial connections On the back of IPE shelf, NTDW26ABE6 cables are to be connected between the rear SL1 and SL3 connectors, and RJ-45 couplers. These connections provide TTY0 and TTY1 for each half of MGXPEC. From the back of shelf, the right side is shelf 0 (SL1) and the left side is shelf 1 (SL3). Page: 7
8 *pictures shown above are from pbxbook.com website. Page: 8
Corrections in Fiber Remote Multi-IPE Interface NTP
Corrections in Fiber Remote Multi-IPE Interface NTP Customer Service Report Number Q00352134 NTP Number 553-3001-022 Software Release Meridian 25.40 In the Fiber Remote Multi-IPE Interface NTP (553-3001-022),
More informationCommunication Server 1000E Upgrade Hardware Upgrade Procedures
Title page Nortel Communication Server 1000 Nortel Communication Server 1000 Release 6.0 Communication Server 1000E Upgrade Hardware Upgrade Procedures Document Number: NN43041-464 Document Release: 03.06
More informationCommunication Server 1000E Upgrade
Communication Server 1000E Upgrade Avaya Communication Server 1000 Release 7.5 Document Status: Standard Document Number: NN43041-464 Document Version: 05.04 Date: December 2011 2011 Avaya Inc. All Rights
More informationNortel Communication Server 1000 Fiber Remote Multi-IPE Interface Fundamentals. Release: 7.0 Document Revision:
Fiber Remote Multi-IPE Interface Fundamentals Release: 7.0 Document Revision: 04.01 www.nortel.com NN43021-556. . Release: 7.0 Publication: NN43021-556 Document release date: 4 June 2010 While the information
More informationCommunication Server 1000E Software Upgrades
Communication Server 1000E Software Upgrades Avaya Communication Server 1000 Release 7.6 Document Status: Standard Document Version: 06.01 Document Number: NN43041-458 Date: March 2013 2013 Avaya Inc.
More informationMeridian 1 Fiber Remote Multi-IPE Interface Description, installation, and maintenance
Meridian 1 Description, installation, and maintenance Document Number: 553-3001-022 Document Release: Standard 3.00 Date: April 2000 Year Publish FCC TM Copyright 1996-2000 Nortel Networks All Rights Reserved
More informationReissue Reason: Adding minimum compatible release (rls 5.0) and minimum MGC loadware (AP01) information to the bulletin.
.. >TECHNICAL SUPPORT. TECHNICAL BULLETIN. MG1010 Media Gateway Introduction Notice: This bulletin replaces bulletin 2010009993.1. This update has been issued to communicate some new information regarding
More informationICP PANEL-TEC PEX3000 II
ICP PANEL-TEC PEX3000 II MODBUS PORT EXPANDER INSTALLATION AND OPERATION GUIDE REVISION HISTORY Revision Date Author Comments 000 29 Aug 2008 Keira Majors Initial release. 001 16 Sep 2008 David Walker
More informationNortel Communication Server 1000 Communication Server 1000E Overview. Release: 6.0 Document Revision:
Communication Server 1000E Overview Release: 6.0 Document Revision: 03.04 www.nortel.com NN43041-110. . Release: 6.0 Publication: NN43041-110 Document release date: 23 October 2009 While the information
More informationOverview of the Cisco VG224 Voice Gateway
CHAPTER 1 This chapter provides a brief description of the Cisco VG224 voice gateway (VG) and contains the following sections: Overview, page 1-1 Cisco VG224 Voice Gateway Deployment, page 1-4 Interfaces
More informationAppendix A Cable Pinouts
Appendix A Cable Pinouts This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module 163 CT1 and CE1 I/O Modules
More informationCable Pinouts. SRP I/O Module
Cable Pinouts A This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module A-1 CT1 and CE1 I/O Modules A-4
More informationLANCNC FTP Data Server for CNC Controls Machine Mount instructions
LANCNC FTP Data Server for CNC Controls Machine Mount instructions 2008-2016 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311 www.calmotion.com Introduction This
More informationCommunication Server 1000 to Rls. 6.0 Upgrades for Technicians
1 Nortel - 922-111 Communication Server 1000 to Rls. 6.0 Upgrades for Technicians Question: 1 A customer with a Communication Server (CS) 1000E Rls. 5.5 HA system with two IPMGs and dual CPPM Signaling
More informationipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide
ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications 2003 Control Technology
More informationCable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB
APPENDIXB This appendix lists the cable specifications for supported modules on the Cisco 7600 series router. The following signal summaries are contained in this appendix: Interface Specifications, page
More informationMeridian 1 Carrier Remote IPE Description, installation, and maintenance
Meridian Description, installation, and maintenance Document Number: 553-3-2 Document Release: Standard 4. Date: April 2 Year Publish FCC TM Copyright 995 2 Nortel Networks All Rights Reserved Printed
More informationPB600/H1 BASIC SYSTEM
PB600/H1 Embedded & Industrial PCs INTERNATIONAL PRODUCTS AND CONFIGURATIONS PB600/H1 BASIC SYSTEM PB600/H1 basic configuration Intel Celeron M 1.5GHz 256 MB RAM kit HDD 40GB 2.5" SATA No FDD Power supply
More informationSitePORTAL Lite TA-SPL32-R48
SitePORTAL Lite TA-SPL32-R48 Quick Connect Guide The TA-SPL32-R48 is a 19 inch, 2 RU rack mountable siteportal Lite (spl). It comes with 8 analog inputs, 8 temperature inputs (sensors sold separately),
More informationDMC DECT Fundamentals Avaya Communications Server 1000
DMC DECT Fundamentals Avaya Communications Server 1000 Release 7.6 NN43120-114 Issue 03.01 Standard March 2013 2013 Avaya Inc. All Rights Reserved. Notice While reasonable efforts have been made to ensure
More informationCisco AS5400 Series Universal Gateways
Cisco AS5400 Series Universal Gateways How to Order a Cisco AS5400 Universal Gateway ORDERING GUIDE PRODUCT OVERVIEW The Cisco AS5400 Universal Gateway offers high-density data services. The rich set of
More informationNetCom Plus 411 (NetCom 411, NetCom 411 PRO)
VS Vision Systems GmbH / Part Number 6670 Main Features Ethernet to serial 4 port RS232 Virtual Com Port driver for Windows Secure Server with latest SSL/AES-256 encryption Operation in Driver Mode, TCP/IP
More informationToolVox Media Gateway *BEFORE YOU BEGIN* Quick Start Guide. Items INCLUDED with your ToolVox Server: Items NOT INCLUDED that you may need:
*BEFORE YOU BEGIN* Items INCLUDED with your ToolVox Server: Software Documentation License key certificate Server power cord/s Front server door keys Spare server drive cables Anti -Static strap Items
More informationCommunication Server 1000E Overview Nortel Communication Server 1000
Communication Server 1000E Overview Nortel Communication Server 1000 7.0 NN43041-110, 04.02 April 2011 2011 Avaya Inc. All Rights Reserved. Notice While reasonable efforts have been made to ensure that
More informationJob Aid: Replacing the Field Replaceable Units (FRUs) for the Avaya G430 Media Gateway
Job Aid: Replacing the Field Replaceable Units (FRUs) for the Avaya G430 Media Gateway! Important: Important: Always check the Avaya Support Website for Product Support Notices at http:// support.avaya.com
More informationCable and Port Specifications
Send documentation comments to mdsfeedback-doc@cisco.com APPENDIXC This appendix includes the cables and connectors used with the Cisco MDS 9100 Series Fixed Configuration Fabric Switch, and it includes
More informationMicrotronix Access 1000/4000 MWI Gateway SIP/SMDI Router and Translator Quick Start Guide
Microtronix Access 1000/4000 MWI Gateway SIP/SMDI Router and Translator Quick Start Guide 0.11.1 Table of Contents 1. Overview...3 1.1 MWI Routing...4 1.2 SMDI to SIP Translation...4 1.3 SIP to SMDI Translation...4
More informationNetCom Plus 113 (NetCom 113, NetCom 113 PRO)
VS Vision Systems GmbH / Part Number 6645 Main Features Ethernet to serial 1 port RS232/422/485 Virtual Com Port driver for Windows Secure Server with latest SSL/AES-256 encryption Operation in Driver
More informationD/ESAM Installation Guide
D/ESAM 8000 Installation Guide Revision 1.6a December 12, 2002 Table of Contents Introduction...1 Overview...1 System...2 Dimensions...3 Control Panel...3 CPU Controller...4 Vadis Chassis...4 System Interconnection...5
More informationStorage/Control I/O Module
CHAPTER 4 The performs two functions: to connect outside interfaces to the system controller and to house the hard disk drive. It plugs into the back of the VCO/4K system and provides the I/O interfaces
More informationModbus Server SIEMENS Algorex (printer port)
IntesisBox Server SIEMENS (printer port) Gateway for the integration of Siemens fire detection panels into enabled control systems. Monitor your fire panels remoy from your Control Center using any commercial
More informationAudio Integration Note
ELAN Home Systems Life Just Got Better Audio Integration Note Manufacturer: Model Number(s): SpeakerCraft MZC-64, MZC-66, MZC-88 Software & Firmware Versions: See table below for tested software and firmware
More informationNetCom Plus 413 (NetCom 413, NetCom 413 PRO)
VS Vision Systems GmbH / Part Number 6675 Main Features Ethernet to serial 4 port RS232/422/485 Virtual Com Port driver for Windows Secure Server with latest SSL/AES-256 encryption Operation in Driver
More informationMICROGATE SERIAL COMMUNICATIONS RUN TIME KIT WINDOWS GUIDE
MICROGATE SERIAL COMMUNICATIONS RUN TIME KIT WINDOWS GUIDE MicroGate Systems, Ltd http://www.microgate.com MicroGate and SyncLink are registered trademarks of MicroGate Systems, Ltd. Copyright 2012-2016
More information1. Carefully unpack the um260 s shipping carton and check the contents for damage.
um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing
More informationCable and Port Specifications
APPENDIXC This appendix provides cable and port specifications, and includes the following sections: Cables and Adapters Provided, page C-1 Console Port, page C-2 COM1 Port, page C-3 MGMT 10/100/1000 Ethernet
More informationNetCom Plus 111 (NetCom 111)
VS Vision Systems GmbH / Part Number 6640 Main Features Ethernet to serial 1 port RS232 Virtual Com Port driver for Windows Secure Server with latest SSL/AES-256 encryption Operation in Driver Mode, TCP/IP
More informationIntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng
IntesisBox Modbus Server KILSEN KSA-7xx User s Manual 08/2013 r1.2 eng Intesis Software S.L. 2013 All rights reserved. Information in this document is subject to change without notice. The software described
More informationWS600/H1 BASIC SYSTEM
WS600/H1 Embedded & Industrial PCs INTERNATIONAL PRODUCTS AND CONFIGURATIONS WS600/H1 BASIC SYSTEM WS600/H1 basic configuration LCD TFT 12.1" Touch-Screen 12.1" Intel Celeron M 1.5GHz 256 MB RAM kit HDD
More informationDisplayport, as shown, has 20 pins and can be used for audio, video, or both audio and video transmission.
EXTERNAL PORTS AND CABLES A video port connects a monitor to a computer using a cable. Video ports and monitor cables transfer analog signals, digital signals, or both. Computers are digital devices that
More informationDomain 3000 Back Panel
Domain 3000 Back Panel The Domain 3000 has 25 I/O ports plus a connector for an external power supply (included) and an LED to indicate that the power is on. Typically, it is placed on a shelf or equipment
More informationRemote RMM-1400 Intelligent Remote Site Management Device. Installation Guide
Remote RMM-1400 Intelligent Remote Site Management Device Guide INSTALLATION GUIDE Westell Technologies Part # 030-300645 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox
More informationL2F Case Study Overview
L2F Case Study Overview Introduction This case study describes how one Internet service provider (ISP) plans, designs, and implements an access virtual private network (VPN) by using Layer 2 Forwarding
More informationGRAVIMETRIC GATEWAY PRE-SALES SUPPORT DOCUMENT. December 3, Computer Communications
GRAVIMETRIC GATEWAY PRE-SALES SUPPORT DOCUMENT December 3, 2003 Computer Communications Maguire Products Inc. 11 Crozerville Road Aston PA, 19014 610-459-4300 COPYRIGHT MAGUIRE PRODUCTS, INC. 2003 Table
More informationFreeNAS Mini and Mini XL Network Upgrade Kit
FreeNAS Mini and Mini XL Network Upgrade Kit June 2017 Edition For more information about the FreeNAS Mini product line and a digital download of this guide, visit www.ixsystems.com/freenas-mini/ Table
More informationIntegration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): MAXSYS Series
Manufacturer: DSC Integration Note Model Number(s): MAXSYS Series Core Module Versions: 4.0 (all builds) Comments: Document Revision Date: 1/30/2013 OVERVIEW AND SUPPORTED FEATURES The DSC MAXSYS Series
More informationCommunication Server 1000E Overview
Communication Server 1000E Overview NN43041-110 Document status: Standard Document version: 0102 Document date: 20 June 2007 All Rights Reserved Sourced in Canada The information in this document is subject
More informationInstallation and Configuration Guide
Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.
More information(Hardware and case keys are provided inside the chassis storage compartment.)
1. Motherboard installation...1 2. Install 3½ and 5¼ drives...3 3. Install PCI components...4 4. Fan installation and setup...5 5. Temperature probe setup...6 6. Connect case leads to motherboard...7 7.
More informationM40e and M160 CIP Installation Instructions
Part No. 530-005365-01 Revision 2 23 January 2002 CIP Description This document describes how to remove and replace the Connector Interface Panel (CIP) on a Juniper Networks M40e Internet router or M160
More informationControlBridge Processors, Touch Panels, and Accessories
CB-TOUCH7-T CB-CP200 CB-ACC-232DCE-30 CB-TOUCH12-T CB-ACC-IR-UNI CB-APP-LIC CB-CP100 CB-ACC-232DTE-30 CB-CP-RMK Product Data Sheet ControlBridge Processors, Touch Panels, and Accessories Overview Control
More informationSerial Data Interface Cards Description
Meridian 1 Serial Data Interface Cards Document Number: 553-3001-107 Document Release: Standard 7.00 Date: January 2002 Year Publish FCC TM Copyright 1994 2002 Nortel Networks All Rights Reserved Printed
More informationCommunication Server 1000S Upgrade Procedures
Title page Nortel Communication Server 1000 Nortel Communication Server 1000 Release 4.5 Communication Server 1000S Upgrade Procedures Document Number: 553-3031-258 Document Release: Standard 3.00 Date:
More informationFortel FRM-501 Compact System Frame User Manual
Fortel FRM-501 User Manual Document Number 81905906560, Rev A Original FortelDTV Text and Format December 2004 PESA Switching Systems 103 Quality Circle, Suite 210 Huntsville, AL 35806 USA Overview Fortel
More informationME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.
ME930C-RJ11 Line: RJ-11 ME930C-RJ11 MAIN MODULE Power -TD -RD INTERFACE MODULE (REAR CARD) TEST -Cntrl In -Cntrl Out Serial: DB25 CN. 7 8 SW1 JB2 1 2 3 RJ-11 CN. JB3 INTERFACE MODULE (REAR CARD) 1 2 3
More informationMix Rack Remote Conversion
Mix Rack Remote Conversion This guide shows how to convert your Mix Rack for remote operation with Stage 48 remote stage boxes. See the Stage 48 Guide in the Stage 48 package for information on how to
More informationFT600/H1-TE BASIC SYSTEM
FT00/H1-TE Embedded & Industrial PCs INTERNATIONAL PRODUCTS AND CONFIGURATIONS FT00/H1-TE BASIC SYSTEM FT00/H1-TE basic configuration LCD TFT 12.1" No Touch-Screen Intel Celeron M 1.5GHz 25 MB RAM kit
More informationCommunication Server 1000E Maintenance
Title page Nortel Communication Server 1000 Nortel Communication Server 1000 Release 4.5 Communication Server 1000E Document Number: 553-3041-500 Document Release: Standard 4.00 Date: April 2007 Year Publish
More informationIntegration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100
Manufacturer: DSC Integration Note Model Number(s): DSC POWER SERIES / IT-100 Core Module Version: 6.4.209 Comments: Document Revision Date: 9/11/2013 OVERVIEW AND SUPPORTED FEATURES The DSC Power Series
More informationAuxiliary Port, Console Port, and Adapter Pinouts for Cisco 1000, 1600, 2500, 2600, and 3600 Series Routers
Auxiliary Port, Port, and Adapter Pinouts for Cisco 1000, 1600, 2500, 2600, and 3600 Series Routers Document ID: 46789 Contents Introduction Prerequisites Requirements Components Used Conventions Auxiliary
More informationHardware Installation Guide Installation (x3350)
Title page Nortel Application Gateway 2000 Nortel Application Gateway Release 6.3 Hardware Installation Guide Installation (x3350) Document Number: NN42400-300 Document Release: Standard 04.03 Date: January
More informationI/O Expansion Board. Control Made Simple
? Control Made Simple I/O Expansion Board West Coast Office 1263 El Camino Real Menlo Park, CA 94025 Phone (650) 853-1444? Fax (650) 853-1405 www.flashcutcnc.com Midwest Office 444 Lake Cook Road, Suite
More informationModbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.
IntesisBox Server - M-Bus (EN 13757-3) Gateway for the integration of M-BUS meters with and based control systems. Integrate M-Bus meters into your master device or system (BMS, SCADA, PLC, HMI, TouchPanels
More informationNetwork audio encoder / decoder with I/O for professional and broadcast applications
Exstreamer 500 PRODUCT MANUAL Network audio encoder / decoder with I/O for professional and broadcast applications Document version 01.00 Release date 28. June 2012 Hardware Rev. 1.x 2010 Barix AG, all
More informationIntegration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401
Manufacturer: DSC Integration Note Model Number(s): Power Series / 5401 Core Module Version: 4.0 (all builds) Comments: Document Revision Date: 1/30/2013 OVERVIEW AND SUPPORTED FEATURES The DSC Power Series
More informationInstalling the DX LCD Display
DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and
More informationMeridian 1 Option 11C Mini Planning and Installation Guide
Meridian 1 Document Number: 553-3021-209 Document Release: Standard 3.00 Date: April 2000 Year Publish FCC TM Copyright 1999 2000 Nortel Networks All Rights Reserved Printed in Canada Information is subject
More informationWT-380 Automated Switching Solution For 48 Twisted Pairs or 40 Twisted Quad Cables
WT-380 defines multi-line, vectored performance testing of Gfast modems using profiles 106 or 212. This is done over 48 (or 40) short or long loops of twisted pair (or twisted quad) cables. The Telebyte
More informationHOW TO ORDER A CISCO AS5350 UNIVERSAL GATEWAY
ORDERING GUIDE HOW TO ORDER A CISCO AS5350 UNIVERSAL GATEWAY PRODUCT OVERVIEW The Cisco AS5350 Universal Gateway offers high-density voice, wireless, fax, and data services. Cisco Any Service for Any Port
More informationSierra Radio Systems. Digital Compass. Reference Manual. Version 1.0
Sierra Radio Systems Digital Compass Reference Manual Version 1.0 Contents Digital compass board RS485 power injector For more information, go to the Sierra Radio Systems web site at www.sierraradio.net
More informationPIX 535. PIX 535 Product Overview CHAPTER
CHAPTER 7 PIX 535 This chapter describes the installation of the PIX 535, and includes the following sections: PIX 535 Product Overview Installing a PIX 535 PIX 535 Feature Licenses Installing Failover
More informationQuick Guide. Extra Communication Card
Quick Guide Extra Communication Card Uninterruptible Power Supply System Version: 1.0 Table of Contents 1. Product Outlook... 3 2. Product Introduction... 3 2.2. RS232 port... 4 2.3. COMM. Slot... 4 2.4.
More informationMultiConnect Adapters
MultiConnect Adapters Serial-to-Serial Adapter Serial-to-Ethernet Adapter Quick Start Guide 2 Multi-Tech Systems, Inc. Quick Start Guide Introduction This guide shows you how to setup your MultiConnect
More informationConnector and Cable Specifications
APPENDIX B This section describes the Catalyst 4224 Access Gateway Switch ports and the cables and adapters used to connect the switch to other devices. This section includes the following topics: Console
More informationSafety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationRapid28iXL PIC Prototyping PCB User Manual
Description Features This is a PCB designed to facilitate the rapid prototyping of a device based on a 28 pin Microchip PIC microcontroller. To allow users to focus on their application, we take care of
More informationEXAMGOOD QUESTION & ANSWER. Accurate study guides High passing rate! Exam Good provides update free of charge in one year!
EXAMGOOD QUESTION & ANSWER Exam Good provides update free of charge in one year! Accurate study guides High passing rate! http://www.examgood.com Exam : 6005.1 Title : Avaya Communication Server 1000 Implementation
More informationRapid40iXL PIC Prototyping PCB User Manual
Description This is a PCB designed to facilitate the rapid prototyping of a device based on a 40 pin Microchip PIC microcontroller. To allow users to focus on their application, we take care of key housekeeping
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationMiniature Asynchronous 4-Wire High Speed Modems
ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
More informationCONVERGE Pro 2 GPIO Expander A General Purpose Input and Output Expander unit for CONVERGE Pro 2. Quick-Start Guide
CONVERGE Pro 2 GPIO Expander A General Purpose Input and Output Expander unit for CONVERGE Pro 2 Quick-Start Guide Table of Contents CONVERGE PRO 2 GPIO EXPANDER... 1 UNPACKING... 1 Parts Included... 1
More informationPIX 515/515E. PIX 515/515E Product Overview CHAPTER
CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses
More informationFiber Remote IPE Description, Installation, and Maintenance
Title page Nortel Networks Communication Server 1000 Nortel Networks Communication Server 1000 Release 4.0 Description, Installation, and Maintenance Document Number: 553-3021-354 Document Release: Standard
More informationFLD2SA-1S FLD2SA-2S Manual
FLD2SA-1S FLD2SA-2S Manual Dual Port Fiber Optic Modem Standalone A00477-3 Rev. A For FLD2SA A00197-3 Rev. A and newer Serial numbers FLD-700084SA and up GDI FLD2SA-1S & FLD2SA-2S Manual A00477-3 Rev.
More informationCONTENTS. 1. Motherboard installation Install 3½ and 5¼ drives Install PCI components Connect case leads to motherboard...
CONTENTS 1. Motherboard installation... 1 2. Install 3½ and 5¼ drives... 3 3. Install PCI components... 4 4. Connect case leads to motherboard... 5 5. Case fan setup... 5 6. Optional device installation...
More informationP/N Operation & Installation Manual Serial Control Transfer Switch Model TM-STS
P/N 92 53626 000-11 Operation & Installation Manual Serial Control Transfer Switch Model TM-STS 92 53626 000 Table of Contents 1.0 SCOPE 1 2.0 INTRODUCTION 1 3.0 SPECIFICATIONS 2 4.0 EQUIPMENT DESCRIPTION
More informationRS-232 to Logic Level Adapter with DB9M Connector and Power LED
PCB-CB-232M RS-232 to Logic Level Adapter with DB9M Connector and Power LED Part Number: PCB-CB-232M (unpopulated PCB, no parts) Features RS-232 to logic level adapter with DB9M connector (DTE style) and
More informationCOPPER-T EXTENDER TABLE OF CONTENTS SECTION 1 - DESCRIPTION SECTION 2 - SPECIFICATIONS... SECTION 3 - INSTALLATION
COPPER-T EXTENDER TABLE OF CONTENTS SECTION - DESCRIPTION...... SECTION - SPECIFICATIONS...... 3 SECTION 3 - INSTALLATION...... SECTION - FRONT PANEL INDICATORS... 7 SECTION - INTERFACE SIGNALS AND CABLES...
More informationWith the use of Mini-Circuits low cost Hand-Flex interconnect cables, multiple matrix configurations can be easily created by the user.
50Ω The Big Deal Flexible mechanical switch system USB and Ethernet Control Full software support All configurations shipped in 2-3 weeks! Typical Applications Automated production testing Laboratory testing
More information09/03/2016. Copyright Amlex Associates Ltd. Notes
09/03/2016 Copyright Amlex Associates Ltd 1 Notice of Rights All rights reserved. No part of this manual, including interior design, may be reproduced or translated into any language in any form, or transmitted
More informationConettix D6690 SafeCom System Guide Conettix DX4020 Installation Guide. Conettix D6600/D6100i Quick Start (this
Quick Start.0 Parts List Conettix /i Communications Receiver/Gateway Table : Conettix System Components Table : Conettix Documentation Qty. Description Conettix Communications Receiver/Gateway AC power
More informationMX ASI-IP & MX IP-ASI
User s Manual MX ASI-IP & MX IP-ASI DVB-ASI Over Ethernet Network Adapters Installation and User Guide T A B L E O F C O N T E N T S MX ASI-IP Network Adapter... 2 Command Line Description... 4 MX IP-ASI
More informationOverview. Port Adapter Overview CHAPTER
CHAPTER This chapter describes the PA-H port adapter and contains the following sections: Port Adapter, page - Interface Specifications, page - LEDs, page - Cables, Connectors, and Pinouts, page - Port
More informationIntesisBox Modbus Server - Honeywell XLS 80
IntesisBox Server - Honeywell XLS 80 Gateway for integration of Honeywell XLS 80 fire panels into (RTU and TCP) enabled control systems. Integrate your Honeywell fire panels into your master device or
More informationCommunication Docks. Communication Dock Accessories
Communication Docks Multi-Dock (Charge Only), 871-020-002 Requires Power Supply 851-075-003 and country-specific AC power cord. Multi-Dock (Ethernet), 871-021-002 Requires Power Supply 851-075-003 and
More informationZEUS Series: microzeus with Flying Bus Boards
ZEUS Series: microzeus with Flying Bus Boards Zeus Series: microzeus with Flying Bus Boards The uzeus is a 4HP power supply module for Eurorack format synthesizers. This version comes with two (2) flying
More informationSerial Link Generic Tank Mode Installation Manual. Pro Fuel Management System. RE Rev C July 00
Serial Link Generic Tank Mode Installation Manual Pro Fuel Management System RE260-337 Rev C July 00 Serial Link Generic Tank Mode Installation Manual RE260-337 Rev C July 00 Certifications and Listings
More informationxin 4, xio 4x4 and xout 4
Data Sheets xin 4, xio 4x4 and xout 4 T +1.425.778.7728 F +1.425.778.7727 www.symetrix.co xin 4 xin 4 Audio input (A/D) expander for SymNet systems that capitalizes on the surplus DSP of a Dante-enabled
More informationCONTENTS. 1. Motherboard installation Install 5¼ and 3½ drives Install PCI components Case fan setup...5
USER S MANUAL CONTENTS 1. Motherboard installation...1 2. Install 5¼ and 3½ drives...3 3. Install PCI components...4 4. Case fan setup...5 5. Connect case leads to motherboard...6 6. Identify the power
More informationDLM. Data Line Monitor. Copyright Advanced Relay Corporation Page 1 of 7. LayGO DLM Description
DLM Data Line Monitor If the Telecom customer decides replacing a legacy network, such as an X.25 PSDN (Packet Switching Data Network), with an IP network, we have to verify the existing physical and protocols
More information