Barriers. Automation & Sensing.

Size: px
Start display at page:

Download "Barriers. Automation & Sensing."

Transcription

1 Automation & Sensing Selection Guide Discrete Input EB3C Discrete Input EB3 Discrete Input Barrier Discrete Output EB3 Discrete Output Switches and Pilot Devices General Information OI Touchscreens PCs Automation Software Power Supplies Sensors Communication Table of Contents ED ighting - Pg. 1 Automation & Sensing - Pg. 21 Safety - Pg. 281 Switching & Controls - Pg. 483 Index - Pg. 1039

2 Selection Guide OI Touchscreens Discrete Input Barrier Selection Guide Model EB3C-**A EB3C-**D EB3-**D Appearance Sensors Power Supplies Automation Software PCs Page Ratings U: Class I, II, III Div1 / Group A, B, C, D, E, F, and G Class I, Zone 0 / [AExia] II C FM: Class I, II, III Div1 / Group A, B, C, D, E, F, and G Class I, Zone 0 / [AExia] II C PTB (ATEX): II(1)G [Exia] IIC: Gas vapor II(1) D[Exia] IIIC: Dust PTB (IECEx) [Exia]IIIC IEC Ex: [Exia] II C CQST: [Ex ia Ga] IIC TIIS: Discrete input barrier [Exia] IIC Switch (EB9Z-A) Exia IICT6 Switch (EB9Z-A1) Exia IIBT6 K: [Exia] II C KCs: [Exia] II C, [Exia D] KR: [Exia] IIC, [Exia] III C (pending) Degree of Protection IP20 IP20 IP20 umber of Channels Relay Output: 1,2,3,5,6,8,10 Transistor Output: 1,2,3,5,6,8,10,16 Relay Output: 1,2,3,5,6,8,10 Transistor Output: 1,2,3,5,6,8,10,16 Power Voltage 100 to 240V AC (U rating: VAC) 24V DC 24V DC Output Relay Transistor (Sink/Source) Relay Transistor (Sink/Source) U: Class I, II, III, Div. 1, Groups A, B, C, D, E, F and G Class I, Zone 0, [AExia] II C PTB (IECEx): [Exia] II C PTB (ATEX): II (1) G [Exia] II C II (1) D [ExiaD] CQST: [Exia] II C TIIS: [Exia] II C EB3-2D: EB3-2R5D: Connection Screw Terminal Screw Terminal, Connector Screw Terminal Mounting Size (excluding projections) 35-mm-wide DI rail Panel mounting 42W 75H 77.5D (1 channel) 65W 75H 77.5D (2, 3 channels) 110.5W 75H 77.5D (5, 6, 8 channels (common)) 171.5W 75H 77.5D (8, 10 channels) 35-mm-wide DI rail Panel mounting Weight (approx.) 380g (EB3C-R10A) 390g (EB3C-R16CD) 42W 75H 77.5D (1 channel) 65W 75H 77.5D (2, 3 channels) 110.5W 75H 77.5D (5, 6, 8 channels (common)) 171.5W 75H 77.5D (8, 10, 16 channels (common)) Relay 2 safety circuits 2 safety circuits, 5 auxiliary circuits 35-mm-wide DI rail / Panel mounting 65.0W 75.0H 77.5D (EB3-2D) 110.5W 75.0H 77.5D (EB3-2R5D) 220g (EB3-2D) 300g (EB3-2R5D) Communication 242

3 Selection Guide Discrete Output Barrier Model EB3-**A EB3-**D Appearance Page 259 Ratings U: Class I, II, III Div1 / Group A, B, C, D, E, F, and G Class I, Zone 0 / [AExia] II C FM: Class I, II, III Div1 / Group A, B, C, D, E, F, and G Class I, Zone 0 / [AExia] II C PTB (ATEX): II(1)G [Exia] IIC: Gas vapor II(1)D [Exia] IIIC: Dust PTB (IEC-Ex) [Exia] IIC [Exia] IIIC CQST: Ex ia Ga IEC Ex: [Exia] II C TIIS: Discrete output barrier [Exia] II C K: [Exia] II C KCS: [Exia] II C, [Exia D] KR: [Exia] IIC, [Exia] III C (pending) Degree of Protection IP20 IP20 umber of Channels 1, 2, 3, 5, 6, 8, 10 1, 2, 3, 5, 6, 8, 10, 16 Power Voltage 100 to 240V AC (U rating: 100 ~ 120V AC) 24V DC Input Transistor input (sink) Transistor input (source) Transistor input (sink) Transistor input (source) Connection Screw Terminal Screw Terminal, Connector Mounting Size (excluding projections) 35-mm-wide DI rail Panel mounting 42W 75H 77.5D (1 channel) 65W 75H 77.5D (2, 3 channels) 110.5W 75H 77.5D (5, 6, 8 channels) 171.5W 75H 77.5D (8, 10 channels) 35-mm-wide DI rail Panel mounting Weight (approx.) 360g (EB3-S10SA) 360g (EB3-S16CSD) Switches and Pilot ights Page 267 Pilot ight and Miniature Pilot ight IP65 (IEC60529) (except for terminals) EB3P-U/I: IP40 Illuminated Switch IP65 (IEC60529) (except for terminals) EB3P-SAW**: IP54 Buzzer IP20 (IEC60529) (except for terminals) 42W 75H 77.5D (1 channel) 65W 75H 77.5D (2, 3 channels) 110.5W 75H 77.5D (5, 6, 8 channels) 171.5W 75H 77.5D (8, 10, 16 channels (common)) OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 243

4 Sensors Power Supplies Automation Software PCs OI Touchscreens EB3C Intrinsically Safe: EB3C Discrete Input Key features: Applicable Standards IEC60079 compliant Dry-contact switches can be connected to the EB3C 8- and 16-circuit types are available in common wiring types, ideal for connection to PCs (DC voltage only) Universal AC power voltage (100 to 240V AC) or 24V DC power (U rating: 100 ~ 120V AC) o grounding required IDEC s original spring-up terminals minimize wiring time Installation: 35-mm-wide DI rail mounting or direct screw mounting Global usage USA: U/FM Europe: CE marking, Global: IECEx ATEX Japan: TIIS China: CQST Korea: KCs Ship class: K (Japan), KR (Korea pending) Entity Barrier Parameters Ta= 60 C, Um= 250V, (Um=125V U only), Uo=13.2V, Io= 14.2mA, Pn-n Io=227.2mA, Po= 750mW at max 16 channels Pn-n Connector Type Po= 46.9mW at each channel Io(mA) Po(mW) Co(μF) ote 1 Added to above table, the next values combined o and Co are allowable; Io(mA) o(mh) 175* * Co(µF) 0.90* * TIIS, K only Ta=60 C, Um=250V * * Combined o(mh) ch 16 ch Seperate Common 16 Uo Io Po Co o 13.2V 14.2mA 46.9mW 0.47μF 87.5mH 13.2V 227.2mA 750mW 0.365μF 0.425mH ote 2 The intrinsic safe apparatus and wirings shall be accordance to following formulas; for example: Ui Uo Ii Io Pi Po Ci+Cc Co i+c o *: Therefore, the values are allowable only at i 1%o and Ci 1%Co of the intrinsic safe apparatus. (In the case of 50% of Co and o parameters are applicable,the maximum capacitance allowed shall not be more than Co = 1 µf for IIB and Co= 600 nf for IIC.) Dry Contact Switches Spring-up Fingersafe Terminals Reduce Wiring Time Dry-contact switches can be connected to the EB3C. Communication Finger-safe B Series CW Series Connector Type MI connector on the non-hazardous side Easy connection to PCs Wiring reduced Various 20-pin MI connectors can be connected 244 HW Series Common Wiring for PC Inputs 8- and 16-circuit types are available in common wiring types, ideal for connection to PCs (DC voltage only).

5 EB3C EB3C Electrical Specifications Ratings Degree of Protection Installation ocation Discrete Input Barrier on-intrinsically Safe Circuit Maximum Voltage (Um) Intrinsically Safe Circuits on-intrinsically Safe Circuits See Certification umbers table below IP20 (IEC60529) Safe indoor place (non-hazardous area) 1-channel Wiring Method Separate Wiring Rated Operating Voltage 12V DC ±10% Rated Operating Current 10 ma DC ±20% Contact Configuration 1O Rated Insulation Voltage (Ui) Relay Output Transistor Output 250V AC 50/60Hz, 250V DC 125V AC 50/60Hz, 125V DC (U rating) 16-channel Common Wiring 250V AC (U rating: 125V AC), 125V DC Thermal Current (lth) 3A (common terminal: 8A) Contact Resistive AC: 750 VA, DC: 72W Allowable AC: 750 VA (cos ø = 0.3 to 0.4) Power Inductive DC: 48W (/R = 7 ms) Rated Resistive Inductive Minimum Applicable Contact Resistance O Time OFF Time Mechanical ife Electrical ife Short-circuit Protection Rated Voltage Maximum Voltage Maximum Current eakage Current Voltage Drop Clamping Voltage Inrush Current O Time OFF Time Short-circuit Protection EB3C General Specifications AC Rated Voltage 100 to 240V AC (U rating: 100 ~ 120V AC) Allowable Voltage Range 85 to 264V AC (U rating: 85 ~ 125V AC) Rated Frequency 50/60 Hz (allowable range: 47 to 63 Hz) Inrush Current 10A (100V AC) 20A (200V AC) 250V AC 3A, 24V DC 3A 250V AC 3A (cos ø = 0.3 to 0.4) 24V DC 2A (/R = 7 ms) 0.1V DC, 0.1 ma (reference value) 50 mω maximum (initial value) 12 ms maximum (rated voltage) 10 ms maximum (rated voltage) 20,000,000 operations minimum (at 18,000 operations/hour, without load) 100,000 operations minimum (at 1,800 operations/hour, rated load) one 24V DC 30V DC 100 ma (connector type: 15 ma) 0.1 ma maximum 1.5V maximum 33V (1W) 0.5A maximum (1 sec) 0.1 ms maximum (resistive load) 0.4 ms (typical) (resistive load) one DC 24V DC 21.6 to 26.4V DC 10A Specifications Dielectric Strength (1 minute, 1 ma) Operating Temperature Storage Temperature Operating Humidity Atmosphere Pollution Degree Insulation Resistance Vibration Resistance Shock Resistance Terminal Style Mounting Damage imits Operation Extremes (relay output only) Damage imits Power Consumption (approx.) Weight (approx.) Between intrinsically safe circuit and nonintrinsically safe circuit: V AC Between AC power and output terminal: 1500V AC Between DC power and transistor output terminal: 1000V AC 20 to +60 C (no freezing) 20 to +60 C (no freezing) 45 to 85% RH (no condensation) 800 to 1100 hpa 2 (IEC60664) 10 MΩ minimum (500V DC megger, between the same poles as the dielectric strength) Panel mounting: 10 to 55 Hz, amplitude 0.75 mm DI rail mounting: 10 to 55 Hz, amplitude 0.35 mm Panel mounting: 10 to 55 Hz, amplitude 0.5 mm DI rail mounting: 10 to 55 Hz, amplitude 0.35 mm Panel mounting: 500 m/s² (3 times each on X, Y, Z) DI rail mounting: 300 m/s² (3 times each on X, Y, Z) M3 screw terminal 35-mm-wide DI rail or panel mounting (M4 screw) 9.6 VA (EB3C-R10A at 200V AC) 4.8 W (EB3C-R16CD at 24V DC) 390g (EB3C-R16CD) EBC3 Certification umbers Certification Certification Ratings Organization umber Class I, II, III Div. 1 U Group A, B, C, D,E, F, and G E Class I, Zone 0 / [AExia] II C FM Class I, II, III Div. 1 Group A, B, C, D,E, F, and G Class I, Zone 0 / [AExia] II C PTB (ATEX) II(1)G [Exia] II C: Gas Vapour, II(1)D [Exia] III C: Dust PTB09 ATEX2046 PTB (IEC-EX) [Exia] II C: Gas, Vapour [Exia] III C: Dust IECEx PTB TIIS Japan Relay barrier: [Exia] II C Switch (EB9Z-A) : Exia II C T6 Switch (EB9Z-A1) : Exia II B T6 TC TC15758 TC15961 Class K [Exia] II C TYPE TEST o. 13T606 CQST [Exia Ga] II C CEx KCs Relay Barrier : [Exia] II C 14-AV4BO-0373 KR [Exia] IIC Pending Class K is Japan Shipping agency approval, Class KR is Korean shipping agency approval. OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 245

6 EB3C Part umbers Communication Sensors Power Supplies Automation Software PCs OI Touchscreens Discrete Input Power Voltage 100 to 240V AC (U rating: 100 ~ 120V AC) 24V DC Connection to on-intrinsically Safe Circuit Screw Terminal Connector Input Wiring Method Separate/Common Wiring Compatible Output Relay umber of Channels Part umber Weight (approx) g 1 EB3C-R01A EB3C-R02A EB3C-R03A EB3C-R05A EB3C-R06A EB3C-R08A EB3C-R10A 380 Common Wiring Only 8 EB3C-R08CA 280 Separate/Common Wiring Compatible Common Wiring Only Separate/Common Wiring Compatible Common Wiring Only Separate/Common Wiring Compatible Common Wiring Only Common Wiring Transistor (Sink/Source) Transistor Relay Sink Source Transistor (Sink/Source) Transistor Sink Source 1 EB3C-T01A EB3C-T02A EB3C-T03A EB3C-T05A EB3C-T06A EB3C-T08A EB3C-T10A EB3C-T08CKA EB3C-T16CKA EB3C-T08CSA EB3C-T16CSA EB3C-R01D EB3C-R02D EB3C-R03D EB3C-R05D EB3C-R06D EB3C-R08D EB3C-R10D EB3C-R08CD EB3C-R16CD EB3C-T01D EB3C-T02D EB3C-T03D EB3C-T05D EB3C-T06D EB3C-T08D EB3C-T10D EB3C-T08CKD EB3C-T16CKD EB3C-T08CSD EB3C-T16CSD 350 Sink EB3C-T16CKD-C Source EB3C-T16CSD-C 330 Accessories Item Part umber Description DI Rail BA000 Steel (1m long, 7.5mm high) BAA1000 Aluminum (1m long, 10.5mm high) End Clip B6 Medium DI rail end clip Static Electricity Caution Plate EB9Z-1 Polyester 20 (W) x 6 (H) mm 246

7 EB3C Internal Circuit Block Diagrams AC Power, Relay Output Type Green ~ 1 P2 2 P3 3 Yellow Yellow Yellow A1 C1 A2 C2 A3 C3 External Wiring Examples DC Power, Transistor Output Type + Green ~ 1 P2 2 P3 3 Yellow Yellow Yellow A1 C1 A2 C2 A3 C3 Circuit Diagrams Connector Wiring, Sink Output Type Green ~ Wiring Examples Yellow Yellow + A1 A16 C1 C2 Hazardous Area on-hazardous Area Transistor Output Type (Ex.: EB3C-T06A) Transistor Sink Output Type (Ex.: EB3C-T08CKD) Transistor Source Output Type (Ex.: EB3C-T08CSD) 1 P2 2 P3 3 P4 4 P5 5 P6 6 A1 C1 A2 C2 A3 C3 A4 C4 A5 C5 A6 C6 100 to 240V AC ote: On the sink/source transistor output type, ter minals A can be used as a positive common line. Relay Output Type (Ex.: EB3C-R06A) 1 P2 2 P3 3 P4 4 P5 5 P6 6 A1 C1 A2 C2 A3 C3 A4 C4 A5 C5 A6 C6 100 to 240V AC Power AC/DC Power 24V DC + 24V DC P2 P3 P4 P5 P6 P7 P8 1 2 A1 A2 A3 A4 A5 A6 A7 A8 C1 C2 Power 24V DC Relay Output Common Wiring Type (Ex.: EB3C-R016CD) 24V DC P2 P3 P4 P5 P6 P7 P8 1 2 P2 P3 P4 P5 P6 P7 P A1 A2 A3 A4 A5 A6 A7 A8 C1 C2 24V DC P A1 A2 A3 A4 A5 A6 A7 A8 C1 C2 A9 A10 A11 A12 A13 A14 A15 A16 C3 C4 Power AC/DC Power 24V DC OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 247

8 EB3C Dimensions (mm) OI Touchscreens Screw Terminal EB3C *05 EB3C *08 EB3C *02 EB3C *06 EB3C *10 EB3C *01 EB3C *03 EB3C *08C EB3C *16C EB3C *05 EB3C * EB3C *01 EB3C *02 EB3C *03 EB3C *06 EB3C *08C EB3C *10 EB3C *16C ø4.4 ø4.4 PCs ø6 hole ø6 hole Communication (4) 65 (4) 65 Automation Software Power Supplies Sensors Mounting Hole Hole ayout ayout (Screw (Screw Mounting) Mounting) 2-M4 tapped or 2-ø4.5 mounting holes 2-M4 tapped or 2-ø4.5 mounting holes Connector Connector Type EB3C T16C -C M4 tapped or 2-ø4.5 mounting holes 2-M4 tapped or 2-ø4.5 mounting holes M4 tapped or 2-ø4.5 mounting holes 2-M4 tapped or 2-ø4.5 mounting holes ø M4 tapped or 4-ø4.5 mounting holes 4-M4 tapped or 4-ø4.5 mounting holes Applicable 3 max. Crimping Crimping Terminal 5.4 Terminal min. ø3.2 min. 3 max. 5.4 min. 6 (4) ø4.5 holes 65 4-M4 or 4-ø4.5 holes 97 Mounting Hole ayout 65 Applicable Crimping Terminal Applicable Crimping Terminal ø3.2 min. ø3.2 min. 6 max. 6 max. 6 max. Stripping the Wire End 3 max. Stripping Solid the Wire Wire End Solid Wire 6 to 8 mm 5.4 min. Solid Wire - Strip wire end Stripping the Wire 6 to 8 End mm Stranded Wire Wire (Ferrule) 6 to - use 8 mma ferrule Stranded Wire (Ferrule) 6 to 8 mm Stranded Wire 6 to (Ferrule) 8 mm to 8 mm 248

9 EB3C Connector Wiring Terminal Arrangement EB3C-T16CKD-C (Sink) CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH1 6 A9 A1 0 A11 A1 2 A13 A1 4 A15 A1 6 C C A1 A2 A3 A4 A5 A6 A7 A8 C1 C2 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 +V COM Internal Circuit EB3C EB3C-T16CSD-C (Source) V (C1) A1-A1 6 COM (C2) CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH1 6 CO M Input I0-I15 A9 A1 0 A11 A1 2 A13 A1 4 A15 A1 6 C C A1 A2 A3 A4 A5 A6 A7 A8 C1 C2 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 V COM Internal Circuit EB3C COM (C2) A1-A16 Input I0-I15 CO M PC CHn An COM PC 1 2 Internal Circui t CHn + An COM Internal Circuit EB3C-T16CKD-C FC4A-16B3 Terminal Output Input Terminal 20 A1 I A9 I A2 I A10 I A3 I A11 I A4 I A12 I A5 I A13 I A6 I A14 I A7 I6 8 7 A15 I A8 I7 6 5 A16 I V COM 4 3 C COM 3 2 COM C 2 1 C C 1 EB3C-T16CSD-C FC4A-16B3 Terminal Output Input Terminal 20 A1 I A9 I A2 I A10 I A3 I A11 I A4 I A12 I A5 I A13 I A6 I A14 I A7 I6 8 7 A15 I A8 I7 6 5 A16 I V COM 4 3 C COM 3 2 COM C 2 1 C C 1 ote: The wiring in dashed line does not affect the operation of the EB3C. Applicable connector is IDEC JE1S-201. Output power for PC outputs is supplied by the EB3C, therefore the PC output does not need an external power supply. OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 249

10 EB3C Wiring Example of Intrinsically Safe External Inputs OI Touchscreens 1. Common Wiring (Maximum 16 circuits) All input lines are wired to a common line inside the intrinsically safe switch (one common line per intrinsically safe circuit). 1. Common Wiring (Maximum 16 circuits) All input lines are wired to a common line inside the intrinsically safe switch (one common line per intrinsically safe circuit). A1 A1 A2 P2 A2 P2 A3 P3 A3 P3 A4 P4 A4 P4 A5 P5 A5 P5 A6 P6 A6 P6 A7 P7 A7 P7 A8 P8 A8 P8 C1 1 C1 1 C2 2 C2 2 A9 P9 A9 P9 A10 0 A10 0 A11 1 A11 1 A12 2 A12 2 A13 3 A13 3 A14 4 A14 4 A15 5 A15 5 A16 6 A16 6 C3 3 C3 3 C4 4 C4 4 PCs Some input lines are wired to a common line inside the intrinsically safe switches, while others are outside switches (one common line per intrinsically safe circuit). Some input lines are wired to a common line inside the intrinsically safe switches, while others are outside switches (one common line per intrinsically safe circuit). Automation Software All input lines are wired to a common line outside the intrinsically safe switch (one common line per intrinsically safe circuit). All input lines are wired to a common line outside the intrinsically safe switch (one common line per intrinsically safe circuit). Power Supplies Sensors Communication A1 A1 C1 1 C1 1 C2 2 C2 2 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A4 P4 A4 P4 C4 4 C4 4 A5 P5 A5 P5 C5 5 C5 5 A6 P6 A6 P6 C6 6 C6 6 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A4 P4 A4 P4 C4 4 C4 4 A5 P5 A5 P5 C5 5 C5 5 A6 P6 A6 P6 C6 6 C6 6 A7 P7 A7 P7 C7 7 C7 7 A8 P8 A8 P8 C8 8 C8 8 A9 P9 A9 P9 C9 9 C9 9 A10 0 A10 0 C10 10 C10 10 A1 A1 A2 P2 A2 P2 A3 P3 A3 P3 A4 P4 A4 P4 A5 P5 A5 P5 A6 P6 A6 P6 A7 P7 A7 P7 A8 P8 A8 P8 C1 1 C1 1 C2 2 C2 2 A1 A1 A2 P2 A2 P2 A3 P3 A3 P3 A4 P4 A4 P4 A5 P5 A5 P5 A6 P6 A6 P6 A7 P7 A7 P7 A8 P8 A8 P8 C1 1 C1 1 C2 2 C2 2 A9 P9 A9 P9 A10 0 A10 0 A11 1 A11 1 A12 2 A12 2 A13 3 A13 3 A14 4 A14 4 A15 5 A15 5 A16 6 A16 6 C3 3 C3 3 C4 4 C4 4 A1 A1 A2 P2 A2 P2 A3 P3 A3 P3 A4 P4 A4 P4 A5 P5 A5 P5 A6 P6 A6 P6 A7 P7 A7 P7 A8 P8 A8 P8 C1 1 C1 1 C2 2 C2 2 A9 P9 A9 P9 A10 0 A10 0 A11 1 A11 1 A12 2 A12 2 A13 3 A13 3 A14 4 A14 4 A15 5 A15 5 A16 6 A16 6 C3 3 C3 3 C4 4 C4 4 A1 A1 C1 1 C1 1 C2 2 C2 2 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A1 A1 C1 1 C1 1 C2 2 C2 2 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A4 P4 A4 P4 C4 4 C4 4 A5 P5 A5 P5 C5 5 C5 5 A6 P6 A6 P6 C6 6 C6 6 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A4 P4 A4 P4 C4 4 C4 4 A5 P5 A5 P5 C5 5 C5 5 A6 P6 A6 P6 C6 6 C6 6 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A4 P4 A4 P4 C4 4 C4 4 A5 P5 A5 P5 C5 5 C5 5 A6 P6 A6 P6 C6 6 C6 6 A7 P7 A7 P7 C7 7 C7 7 A8 P8 A8 P8 C8 8 C8 8 A9 P9 A9 P9 C9 9 C9 9 A10 0 A10 0 C10 10 C10 10 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A4 P4 A4 P4 C4 4 C4 4 A5 P5 A5 P5 C5 5 C5 5 A6 P6 A6 P6 C6 6 C6 6 A7 P7 A7 P7 C7 7 C7 7 A8 P8 A8 P8 C8 8 C8 8 A9 P9 A9 P9 C9 9 C9 9 A10 0 A10 0 C10 10 C10 10 A1 A1 A2 P2 A2 P2 A3 P3 A3 P3 A4 P4 A4 P4 A5 P5 A5 P5 A6 P6 A6 P6 A7 P7 A7 P7 A8 P8 A8 P8 C1 1 C1 1 C2 2 C2 2 A1 A1 A2 P2 A2 P2 A3 P3 A3 P3 A4 P4 A4 P4 A5 P5 A5 P5 A6 P6 A6 P6 A7 P7 A7 P7 A8 P8 A8 P8 C1 1 C1 1 C2 2 C Separate Wiring Each input line of the EB3C makes up one independent intrinsically safe circuit. A1 A1 C1 1 C1 1 C2 2 C2 2 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A4 P4 A4 P4 C4 4 C4 4 A5 P5 A5 P5 C5 5 C5 5 A6 P6 A6 P6 C6 6 C6 6 A1 A1 C1 1 C1 1 A2 P2 A2 P2 C2 2 C2 2 A3 P3 A3 P3 C3 3 C3 3 A4 P4 A4 P4 C4 4 C4 4 A5 P5 A5 P5 C5 5 C5 5 A6 P6 A6 P6 C6 6 C6 6 A7 P7 A7 P7 C7 7 C7 7 A8 P8 A8 P8 C8 8 C8 8 A9 P9 A9 P9 C9 9 C9 9 A10 0 A10 0 C10 10 C10 10 Diagram Symbols Serial-Parallel Connection of Switches Contacts in one switch Diagram Symbols (EB9Z-A or EB9Z-A1) Serial-Parallel Connection of Switches Contacts in one switch (EB9Z-A or EB9Z-A1) One intrinsically safe circuit (maximum 16 circuits) One intrinsically safe circuit (maximum 16 circuits) 1 2 A1 C1 C2 1 2 A1 C1 C2 otes As shown in the diagram on the left, the required number of contacts in one switch (3 contacts in the example at left) can be added to the contacts in one switch connected to one input channel. Similarly, a required number of contacts in one switch can be added to a common line connected to multiple input channels. The capacitance and inductance of the added contacts in one switch must be included in the calculation of the wiring capacitance and inductance in Precautions for Operation, 5. Wiring for Intrinsic Safety, (7). In addition, a required number of contacts can be added in the enclosure of contacts in one switch. In this case, however, do not include the capacitance and inductance in the calculation of the wiring capacitance and inductance. Instead, make sure that the internal capacitance (Ci) and internal inductance (i) are within the values shown in the table Switch Explosion-Protection Specifications (Japan only)

11 EB3C Recommended Connector Cable for Connector Types Description o. of Poles ength (m) Part umber Shape Applicable Type I/O Terminal Cable With Shield Without Shield Cable with Crimping Terminal 40-pin Cable for PC FC9Z-H A, FC9Z-H B Internal Connection Fujitsu Connector FC-367J024-AU/F B A (Connection Side) BX9Z-H B Internal Connection Connector A IDEC JE1S Fujitsu Connector FC-367J040-AU/F B A IDEC Connector JE1S C (Connection Side) 0.5 FC9Z-H050A20 1 FC9Z-H100A20 2 FC9Z-H200A20 3 FC9Z-H300A FC9Z-H050B20 1 FC9Z-H100B20 2 FC9Z-H200B20 3 FC9Z-H300B20 1 BX9Z-H100E4 2 BX9Z-H200E4 3 BX9Z-H300E4 1 BX9Z-H100B 2 BX9Z-H200B 3 BX9Z-H300B FC9Z-H E4 Internal Connection IDEC Connector JE1S (Connection Side) Connector B IDEC JE1S (Connection Side) (Connection Side) (Connection Side) Y-shaped Compresion Terminal (Marking Tube o.) Connector B Connector A IDEC MicroSmart I/O Module IDEC MicroSmart I/O Module Screw Terminal Mitsubishi A Series Input Module (positive common) EB3C-T16CKD-C OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 251

12 EB3C Communication Sensors Power Supplies Automation Software PCs OI Touchscreens Installing the EB3C Intrinsically Safe 1. The EB3C can be installed in any direction. 2. Install the EB3C intrinsically safe barrier in a safe area (non-hazardous area) in accordance with intrinsic safety ratings and param eters. To avoid mechanical shocks, install the EB3C in an enclosure which suppresses shocks. 3. When installing or wiring the EB3C, prevent electromagnetic and electrostatic inductions in the intrinsically safe circuit. Also prevent the intrinsically safe circuits from contacting with another intrinsically safe circuit and any other circuits. Maintain at least 50mm clearance, or provide a metallic separating board between the intrinsically safe circuit and non-intrinsically safe circuit. When providing a metallic separating board, make sure that the board fits closely to the enclosure (top, bottom, and both sides). Allowable clear ance between the enclosure and board is 1.5mm at the maximum. The clearance of 50mm between the intrinsically safe cir cuit and non-intrinsically safe circuit may not be sufficient when a motor circuit or high-voltage circuit is installed nearby. In this case, provide a wider clearance between the circuits referring to 5 (3) Minimum Parallel Distance between the Intrinsically Safe Circuit and Other Circuits. 4. In order to prevent contact between intrinsically safe circuits and non-intrinsically safe circuits, mount EB3C units with terminals arranged in the same direction. on-intrinsically Safe Circuit EB3C EB3C EB3C Intrinsically Safe Circuit 5. Maintain at least 6mm (or 3mm according to IEC : 1999) clearance between the terminal of an intrinsically safe circuit and the grounded metal part of a metal enclosure, and between the relay terminal block of an intrinsically safe circuit and the grounded metal part of a metal enclosure. 6. For installing the EB3C, mount on a 35mm-wide DI rail or directly on a panel using screws. Make sure to install securely to withstand vibration. When mounting on a DI rail, push in the clamp completely. Use the B6 end clips on both sides of the EB3C to prevent from moving sideways. 7. Excessive extraneous noise may cause malfunction and damage to the EB3C. When extraneous noise activates the voltage limiting circuit (thyristor), remove the noise source and restore the power. Terminal Wiring 1. Using a ø5.5mm or smaller screw driver, tighten the termi nal screws (including unused terminal screws) to a torque of 0.6 to 1.0 m (recommended value). 2. Make sure that IP20 is achieved when wiring. Use insulation tubes on bare crimping terminals. 3. To prevent disengaged wires from contacting with other intrinsically safe circuits, bind together the wires of one intrinsically safe circuit. 4. When the adjacent terminal is connected to another intrinsi cally safe circuit, provide an insulation distance of at least 6mm. Switches in the Hazardous Area 1. A switch contains the switch contact, enclosure, and internal wiring. A switch contact refers to an ordinary switching device which consists of contacts only, such as a pushbut ton switch. See below. EB3C EB3C Intrinsically Safe Circuit Applicable Switches Control Switches Sensing Switches ote: Push-pull Switches Twisting Switches ever and Slide Switches Displacement Switches Pushbutton, Foot, Trigger, Rocker, Grip Rotary, Selector, Cam, Drum, Thumb wheel Toggle, Multidirectional, Wobble stick, ever, Slide switch Microswitch, imit, Magnetic proximity, Door, Reed, Mercury iquid level Pressure, Temperature evel Switches Others For installation in hazardous areas and connection to the EB3C, use switches which are certified, approved, or considered to be simple apparatus in relevant standards in each country. 2. When the switch has internal wiring or lead wire, make sure that the values of internal inductance (i) and capacitance (Ci) are within the certified values. 3. Enclose the switch contact s bare, live part in an enclosure of IP20 or higher protection. 4. Depending on the explosion-protection specifications according to TIIS, the exposed area of the plastic switch opera tor is limited as follows: Exia II CT6 (EB9Z-A): 20cm 2 maximum Exia II BT6 (EB9Z-A1): 100cm 2 maximum 5. Attach the certification mark supplied with the EB3C on the EB9Z-A or EB9Z- A1 switch (for Japanese applications). 6. When the switch operator of the plastic enclosure has a wider exposed area than the following limits, attach a caution label. II C: 20 cm 2 maximum II B: 100 cm 2 maximum Caution To prevent electrostatic charges, do not rub the switch surface during operation. Use a soft cloth dipped with water for cleaning. Caution abel Example 7. For the 1-circuit separate wiring, a resistor to prevent reed switch contact welding and an ED miniature pilot light can be connected in series with the contact. See below. Use the terminal screw of M3 or larger. Applicable Resistor Ratings Resistance 100Ω maximum Rated Wattage 0.5 to 3W Type Metal (oxide) film resistors R Reed Switch Terminal Block EB3C I series ED miniature pilot lights Output Specifications 1. When wiring the output from the EB3C, connect the non-intrinsically safe circuit to terminals A and C. The EB3C out put circuit is not equipped with short-circuit protection. If required, provide a protection in the external circuit. 2. Relay Output Some types of loads generate reverse emf (such as sole noids) or cause a large inrush current (incandescent lamps), resulting in a shorter operation life of output relay contacts. The operation life of contacts can be extended by preventing the reverse emf using a diode, RC, or varistor, or by suppressing the inrush current using a resistor or R. Contacts are made of gold-clad silver. When using at a small current and a low voltage (reference value: 0.1mA, 0.1V), test the contact on the actual circuit in advance

13 EB3C 3. Transistor Output When connecting a small load, the load may not turn off because of a leakage current, even though the transistor output is turned off. If this is the case, connect a resistor in parallel with the load to bypass the leakage current. When an excessively high voltage (clamps at 33V, 1W) or a reverse voltage is applied to the output terminals, the clamping circuit or output transistor may be damaged. When driving an inductive load, be sure to connect a diode across the load to absorb reverse emf. Cn *: Surge Absorber Example of Overvoltage Absorption Circuit 4. In the common wiring only types, the output terminals are not isolated from each other. 5. When connecting the connector type EB3C s in parallel, use one power supply to power the EB3C s. Do not connect any wiring to the C1 and C2 terminals. Wiring for Intrinsic Safety 1. The voltage applied on the general circuit connected to the non-intrinsically safe circuit terminals of the EB3C relay bar rier must be 250V AC, 50/60Hz, or 250V DC at the maxi mum under any conditions, including the voltage of the input power and the internal circuit. 2. When wiring, take into consideration the prevention of elec tromagnetic and electrostatic charges on intrinsically safe circuits. Also, prevent intrinsically safe circuits from contact ing with other circuits. 3. The intrinsically safe circuits must be separated from non-intrinsically safe circuits. Contain intrinsically safe circuits in a metallic tube or duct, or separate the intrinsically safe cir cuits referring to the table below. ote: Cables with a magnetic shield, such as a metallic sheath, prevent electromagnetic induction and electrostatic induction, however, a non-magnetic shield prevents electrostatic induction only. For non-magnetic shields, take a preventive measure against electro magnetic induction. Finely twisted pair cables prevent electromagnetic induc tion. Adding shields to the twisted pair cables provides pro tection against electrostatic induction. Minimum Parallel Distance between the Intrinsically Safe Circuit and Other Circuits (mm) Voltage and Current of Other Circuits An Over 100A * 100A or less 50A or less 10A or less Over 440V V or less V or less V or less V or less When identifying intrinsically safe circuits by color, use light blue terminal blocks and cables. 5. When using two or more EB3C s to set up one intrinsically safe circuit in the common wiring configuration, interconnect two neutral terminals (1 through 10) on each EB3C between adjacent EB3C s in parallel. 6. Make sure that the power of the EB3C and contact are turned off before starting inspection or replacement. 7. When wiring the intrinsically safe circuit, determine the dis tance to satisfy the wiring parameters shown below. ote that parameters are different between separate wiring and common wiring. a. Wiring capacitance Cw Co (Ci + 2 nf) Co: Maximum external capacitance of the EB3C Ci: Internal capacitance of the switch : The number of switches connected in series or parallel (the number is infinite) b. Wiring inductance w o (i + 5 µh) o: Maximum external inductance of the EB3C i: Internal inductance of the switch : The number of switches connected in series or parallel (the number is infinite) c. Wiring resistance Rw Rw: Allowable wiring resistance d. Allowable wiring distance D (km) is the smallest value of those calculated from the capacitance, inductance, and resistance. D Cw/C C (nf/km): Capacitance of cable per km D w/ (mh/km): Inductance of cable per km D Rw/2R R (Ω/km): Resistance of cable per km ote: For the details of wiring the intrinsically safe circuits, refer to a rel evant test guideline for explosion-proof electric equipment in each country. 8) Applicable Wire Size 0.5 to 2.0mm 2 (AWG20 to AWG14): two wires However, one wire for 2.0 mm 2 (AWG14) Mounting Bracket The following mounting brackets can be used to install the EB3C relay barriers and EB3 lamp barriers on the mounting holes of IBRC contact signal transducer, IBP pilot relay barrier, and IBZ buzzer. o. of Channels Part o. Dimension (mm) A B C 1 EB9Z-K EB9Z-K EB9Z-K EB9Z-K EB9Z-K EB9Z-K Dimensions C B A ø5 (four) M4 (two or four) : EB9Z-K10 only 7 All dimensions in mm. OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 253

14 EB3 EB3 Discrete Input Barrier with Redundant Output Communication Sensors Power Supplies Automation Software PCs OI Touchscreens Build a safety system in an explosive atmosphere. Key features: Safety Performance Performance level e Category 4 [Exia] II C Ensures safety and machine safety in an explosive atmosphere Machine safety system can be built in compliance with ISO Category 4, Performance level e. Safety input devices applicable in any explosive gas and hazardous areas are available. Available with auxiliary inputs (5 points) used to monitor the operating status of safety input devices Global usage USA (U), Global IEC-Ex, Europe (ATEX), Japan (TIIS), China (CQST) Machine safety: TÜV Rheinland o grounding required Entity Barrier Parameters Ta= 60 C, Um= 250V, (Um=125V U only), Uo=13.2V, Io= 14.2mA, Po= 46.9mW at each channel Pn-n Io=227.2mA, Po= 750mW at max 16 channels Pn-n Io(mA) Combined Po(mW) o(mh) TIISI only Ta=60 C, Um=250V 1 ch Seperate 5 ch Common Uo 13.2V 13.2V Co(μF) Io 14.2mA 227.2mA Po 46.9mW 750mW Co 0.47μF 0.28μF ote 1 Added to above table, the next values combined o and Co are allowable; o 87.5mH 0.56mH Io(mA) o(mh) 175* * * Co(µF) 0.90* * * ote 2 The intrinsic safe apparatus and wirings shall be accordance to following formulas; for example: Ui Uo Ii Io Pi Po Ci+Cc Co i+c o *: Therefore, the values are allowable only at i 1%o and Ci 1%Co of the intrinsic safe apparatus. (In the case of 50% of Co and o parameters are applicable,the maximum capacitance allowed shall not be more than Co = 1 µf for IIB and Co= 600 nf for IIC.) Discrete Input Barrier with Redundant Output 2 2O Without Without 2 2O 5 (1 common) 5O (1 common) Auto reset (Auto start) Manual reset (Manual start) Auto reset (Auto start) Manual reset (Manual start) EB3-A2D EB3-M2D EB3-A2R5D EB3-M2R5D 1. A maximum of five monitor contacts from safety input devices can be connected to the auxiliary input terminals. In addition, non-safety input devices can also be connected to the auxiliary input terminals. 2. On auto reset (auto start) models, when the safety condition is met (two safety inputs are both on), safety outputs are turned on automatically. Connect the reset (start) input terminals Y1 and Y2 together except for the following cases: When connecting a contactor or force guided relay to the safety output of the EB3, connect the C contacts of the contactor or force guided relay to the reset (start) input terminals Y1 and Y2 of the EB3 for use as a backcheck input signal. 3. On manual reset (manual start) models, while the safety condition is met (two safety inputs are both on), safety outputs are turned on at the falling edge of the reset switch (start switch) signal (OFF O OFF) (start off check). Manual reset (manual start) models have a monitoring function of reset switch contacts (detection of welded contacts). Use O contacts of a momentary switch for the reset (start) input. When connecting a contactor or force guided relay to the safety output of the EB3, connect the C contacts of the contactor or force guided relay to the reset (start) input terminals Y1 and Y2 of the EB3 for use as a backcheck input signal

15 EB3 Selection Guide 1. Selecting the reset (start) function Auto reset (auto start): Select this model when connecting safety control devices, such as safety relay modules or safety controllers, to the EB3 safety outputs to set up a safety system, using the reset (start) function of the safety control device. Select this model when connecting contactors or force guided relays to the EB3 safety outputs to set up a safety system, and a risk assessment on the entire system has not found any safety problem in using auto reset (auto start). Manual reset (manual start): Select this model when connecting contactors or force guided relays to the EB3 safety outputs to set up a safety system, and a risk assessment on the entire system has found that manual reset (manual start) is necessary. 2. Selecting the auxiliary outputs Without auxiliary outputs: Select this model when the operating status of safety input devices are not monitored. With auxiliary outputs: Select this model when the operating status of safety input devices are monitored or when non-safety input devices are also connected. Specifications EB3 General Specifications Rated Power Voltage 24V DC EB3 Safety Specifications Category 4 Power Voltage Range 20.4 to 26.4V DC Performance evel (P) e 20 to +60 C (no freezing) Mean Time to Dangerous Failure (MTTFd) 100 years Operating Temperature U: 20 to +40 C (no freezing) Diagnostic Range 99% minimum Operating Humidity 45 to 85% RH Calculation conditions for MTTFd (no condensation) t cycle : Mean operation cycle = 1 hour h Power Without auxiliary output 5.5W maximum op : Mean operation hours per day = 24 hours d op : Mean operation days per year = 365 days Consumption With auxiliary output 7.0W maximum ote: When t cycle is shorter than 1 hour, MTTFd will decrease Contacts 13-14, O Resistive 30V DC, 1A Safety Rated Inductive DC-13, 24V, 1A Output Response Turn on 100 ms maximum (rated voltage) Turn off 20 ms maximum Contacts A* - C1 5O/1 common Auxiliary Output Mounting Rated Response (rated voltage) *: Channel umbers: 1 to 5 Resistive Turn on Turn off 24V DC, 3A, common terminal 5A max. 15 ms maximum 10 ms maximum DI rail or panel mounting EB3 Certifications Certification Organization Ratings Certification umber U Class I, Zone 0, [AExia] II C Class I, II, III, Div. 1, Groups A, B, C, D, E, F and G E PTB (IEC-Ex) [Exia] II C, [Exia D] IEC Ex PTB PTB (ATEX) II (1) G [Exia] II C II (1) D [Exia D] PTB 09 ATEX 2046 Discrete Input with Redundant Output [Exia] II C TC18753 TIIS Switch (EB9Z-A) Exia II CT6 TC15758 Switch (EB9Z-A1) Exia II BT6 TC15961 CQST [Exia] IIC CEx OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 255

16 EB3 Dimensions (mm) OI Touchscreens EB3-A2D EB3-M2D 65.0 EB3-A2R5D EB3-M2R5D Terminal Functions 24V DC Power Y1-Y2 Reset input (Start input) Safety input Safety input 2 1, 2 Signal ground P*-3 Auxiliary input PCs Mounting Hole ayout EB3-A2D EB3-M2D EB3-A2R5D EB3-M2R5D Safety output Safety output 2 A*-C1 Auxiliary output *: 1 to 5 2-M4 tapped or 2-ø4.5 drilled holes 65 2-M4 tapped or 2-ø4.5 drilled holes 65 Automation Software Power Supplies Sensors 51 EB3 System Configuration Examples 1:1 connection with a safety input device, compliant with Category 4 Safety Input Device Safety Input Device EB3-A2D EB3-M2D 97 Barrier Safety Output Barrier Safety Output Safety Control Device Safety Contactor Safety Control Device PC Safety Contactor PC Safety Output Backcheck Input Safety Contactor Connection with multiple safety input devices, capable of monitoring up to 5 contact operations, compliant with Category 3 For monitoring operating statuses of safety input devices located in a non-hazardous area Safety Input Devices Connected in Series Safety Input Devices Connected in Series Hazardous Area Hazardous Area Monitor on-hazardous Area on-hazardous Area EB3-A2R5D EB3-M2R5D Backcheck Input Reset (Start) Input Barrier Safety Output Auxiliary Output (Monitor Output) Barrier Safety Output Backcheck Input Reset (Start) Input Reset (Start) Input Safety Output Backcheck Input Reset (Start) Input Safety Contactor A safety relay module or safety controller is used to set up a safety circuit, using the reset (start) function of the safety relay module or safety controller. The reset (start) function is used to set up a safety circuit, without using a safety relay module or safety controller. Communication A safety relay module or safety controller is used to set up a safety circuit, using the reset (start) function of the safety relay module or safety controller. The manual reset (manual start) function of the EB3 is used to set up a safety circuit, without using a safety control device. Monitor Auxiliary Output (Monitor Output) 256

17 EB3 Installing a reset switch in a hazardous area, using auxiliary input and output Safety Input Devices Reset (Start) Switch Other Input Device Safety Input Devices Reset (Start) Switch Other Input Device Hazardous Area on-hazardous Area EB3-A2R5D EB3-M2R5D Barrier Safety Output Reset (Start) Output Other Output Barrier Safety Output Backcheck Input Reset (Start) Input Other Output Safety Control Device PC Safety Contactor PC Safety Output Backcheck Input Safety Input Devices Connectable to Safety Input Terminals (Examples) Emergency stop switch: Safety switch: otes for Operation (on-illuminated) XW1E-BV402M-R, X4E-B412MRH HS6B-02B05, HS1B-02R 1. Do not disassemble, repair, or modify the EB3 discrete input barrier with redundant output, otherwise the safety characteristics may be impaired. 2. Use the EB3 within its specification values. 3. The EB3 can be mounted in any direction. 4. Mount the EB3 on a 35-mm-wide DI rail or directly on a panel surface using screws. When mounting on a DI rail, push in the clamp and use end clips to secure the EB3. When mounting on a panel surface, tighten the screws firmly. 5. Excessive noise may cause malfunction or damage to the EB3. When the internal voltage limiting circuit (thyristor) has shut down the power due to noise, remove the cause of the noise before powering up again. 6. The internal power circuit contains an electronic fuse to suppress overcurrents. When the electronic fuse has tripped, shut down the power, remove the cause of the overcurrent before powering up again. 7. Use crimping terminals with insulation sheath for wiring. Tighten the terminal screws, including unused terminal screws, to a recommended tightening torque of 0.6 to m using a screwdriver of ø5.5 mm in diameter. 8. Before inspecting or replacing the EB3, turn off the power. Safety Contactor Instructions otes for Machine Safety 1. Operate the safety input device to check the EB3 functionality everyday. 2. For safety input devices, such as safety switches or emergency stop switches, connected to the EB3, use safety standard-compliant devices with direct opening action and 2C contacts. 3. Do not use the auxiliary input as a safety input. 4. For safety control devices connected with the EB3, use machine safety standard-compliant devices with a disparity detection function. 5. Use safety inputs and safety outputs in a circuit configuration compliant with safety requirements. 6. To calculate the safety distance, take into consideration the response time of all devices comprising the system, such as the EB3 and safety devices connected to the EB3. 7. Separate the input and output wiring from power lines and motor lines. 8. When using multiple EB3 discrete input barriers with redundant output, do not connect one switch to more than one EB3. Use separate switches for each EB3. 9. To ensure EMC, use shielded cables for safety inputs and auxiliary inputs. Connect the shield to the FG of the control panel on which the EB3 is mounted. 10. For protection against overcurrents, connect an IEC compliant 2A fast-blow fuse (5 20 mm). 11. Evaluate the ISO category and performance level in consideration of the entire system. OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 257

18 EB3 Sensors Power Supplies Automation Software PCs OI Touchscreens Safety otes 1. Install the EB3 in an enclosure capable of protecting against mechanical shocks at a hazardous location in accordance with intrinsic safety ratings and parameters. 2. Install and wire the EB3 so that the EB3 is not subject to electromagnetic and electrostatic induction and does not contact with other circuits. For example, keep a minimum spacing of 50 mm between intrinsically safe and non-intrinsically safe circuits, or provide a metallic separating board between the intrinsically safe circuit and non-intrinsically safe circuit. When providing a metallic separating board, make sure that the board fits closely to the enclosure (top, bottom, and both sides). Allowable clearance between the board and the enclosure is 1.5 mm at the maximum. When a motor circuit or high-voltage circuit is installed nearby, keep a wider spacing than 50 mm between intrinsically safe and non-intrinsically safe circuits. 3. Keep a minimum spacing of 3 mm between the terminal or relay terminal block of the intrinsically safe circuit and the grounded metal parts of the metal enclosure. 4. Connect the terminals so that IP20 is ensured. 5. To prevent disengaged wires from contacting with other intrinsically safe circuits, bind together the end of wires. 6. Make sure that the voltage of the power supply for the devices connected to the non-intrinsically safe circuit or the internal voltage of such devices does not exceed 250V AC/DC 50/60 Hz (U rating: 125V AC 50/60 Hz) or 250V DC (U rating: 200V DC) under any normal and abnormal conditions. 7. Make sure that the wiring of intrinsically safe circuits does not contact with other circuits or is not subject to electromagnetic and electrostatic inductions, otherwise protection from hazards is not ensured. 8. When identifying intrinsically safe circuits by color, use light blue terminal blocks and cables. 9. When wiring the intrinsically safe circuit, determine the distance to satisfy the wiring parameters shown below. a) Wiring capacitance Cw Co Ci Co: Intrinsically safe circuit allowable capacitance Ci: Internal capacitance of switches b) Wiring inductance w o i o: Intrinsically safe circuit allowable inductance i: Internal inductance of switches c) Wiring resistance Rw Rw: Allowable wiring resistance Switches in the Hazardous Area 1. A switch contains the switch contact, enclosure, and internal wiring. A switch contact refers to an ordinary switching device which consists of contacts only. 2. When the switch has internal wiring or lead wire, make sure that the values of internal capacitance (Ci) and inductance (i) are within the certified values. 3. Enclose the bare live part of the switch contact in an enclosure of IP20 or higher protection. Communication 258

19 EB3 EB3 Discrete Output 126 types of pilot lights and buzzers can be connected. Illuminated pushbuttons and illuminated selector switches can be connected by combining with the EB3C discrete input barrier. o grounding required. Key features: Discrete Output Barrier Pilot ight (separate wiring) Pilot ight (common wiring) Illuminated Pushbutton Illuminated Selector Switch Buzzer (separate wiring) Ratings [Exia] II C Exia II CT6 Exia II CT4 Exia II CT4 Exia II CT4 Exiab II CT6 IEC60079 compliant Compact and lightweight 8- and 16-channel types are available in common wiring types, ideal for connection to PCs. 16-circuit types are also available with a connector. Universal AC power voltage (100 to 240V AC or 24V DC power [U rating: 100 ~ 120V AC]) o grounding required IDEC s original spring-up terminal minimizes wiring time. Installation, 35-mm-wide DI rail mounting or direct screw mounting ø6, ø8, ø10, ø22 and ø30 pilot lights available Illuminated pushbuttons and illuminated selector switches can be connected by combining with the EB3C discrete input barrier. Illumination colors: Amber, blue, green, red, white, and yellow (pushlock turn reset type: red only) Continuous and intermittent sound types are available for buzz ers (ø30). Global usage USA: U/FM Europe: CE marking Global: IECEx, ATEX Japan: TIIS China: CQST Korea: KCs Ship class: K (Japan), KR (Korea) ISTED FM APPROVED Illuminated Pushbutton/Selector Switches Illuminated pushbutton/selector switches can be used with the combination of EB3C and EB3. Spring-up Fingersafe Terminals Reduce Wiring Time Entity Barrier Parameters Ta= 60 C, Um= 250V, (Um=125V U only), Uo=13.2V, Io= 14.2mA, Po= 46.9mW at each channel Pn-n Io=227.2mA, Po= 750mW at max 16 channels Pn-n Io(mA) Combined Po(mW) o(mh) Finger-safe TIIS, K only Ta=60 C, Um=250V 1 ch Seperate 16 ch Common Uo 13.2V 13.2V Co(μF) Io 14.2mA 227.2mA Po 46.9mW 750mW Co 0.47μF 0.365μF ote 1 Added to above table, the next values combined o and Co are allowable; o 87.5mH 0.425mH Io(mA) o(mh) 175* * * Co(µF) 0.90* * * ote 2 The intrinsic safe apparatus and wirings shall be accordance to following formulas; for example: Ui Uo Ii Io Pi Po Ci+Cc Co i+c o *: Therefore, the values are allowable only at i 1%o and Ci 1%Co of the intrinsic safe apparatus. (In the case of 50% of Co and o parameters are applicable,the maximum capacitance allowed shall not be more than Co = 1 µf for IIB and Co= 600 nf for IIC.) Common Wiring for PC Inputs 8- and 16-circuit types are available in common wiring types, ideal for connection to PCs (DC voltage only). Connector Type MI connector on the non-hazardous side Easy connection to PCs Wiring is reduced by 90% Various 20-pin MI connectors can be connected. OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 259

20 EB3 Sensors Power Supplies Automation Software PCs OI Touchscreens Electrical Specifications Ratings Degree of Protection Discrete Output Barrier Installation ocation Pilot ight, Illuminated Switch, Buzzer on-intrinsically Safe Circuit Maximum Voltage (Um) Intrinsic safety type (IEC compliant) [Exia] II C IP20 (IEC60529) Safe indoor place (non-hazardous area) For zone 0, 1, 2 hazardous areas For zone 1 and 2 hazardous areas Specifications General Specifications Communication 250V AC 50/60Hz, 250V DC U value: 125V AC Operation Input O, Output O (1:1) Certifications Certification Ratings Organization Class I, II, III Div. 1 U Group A, B, C, D, E, F, and G Class I, Zone 0 [AExia] II C Class I, II, III Div. 1 FM Group A, B, C, D, E, F, and G Class I, Zone 0 [AExia] II C E Certification o. PTB (IEC-Ex) [Exia] IIC: Gas vapor IECEx PTB PTB (ATEX) TIIS K II(1)G [Exia] IIC: Gas vapor II(1)D [Exia] IIIC: Dust Discrete output barrier: [Exia] II C Pilot light/miniature pilot light: (separate wiring): Exia II CT6 Pilot light/miniature pilot light: (common wiring): Exia II CT4 Illuminated switch: Exia II CT4 Buzzer: Exib II CT6 Discrete output barrier: [Exia] II C Buzzer: Exib II CT6 PTB09 ATEX2046 TC20541 TC16361 TC16360 TC16362 TC20797 Type Test o. 13T606 pending CQST [Exia Ga] IIC CEx KCs Discrete output barrier: [Exia] II C Buzzer: Exib II CT6 KR [Exia] IIC pending KCS14-AV4BO-0375 pending Power Voltage Type AC Power DC Power Rated Power Voltage 100 to 240V AC (U rating: 100 ~ 120V AC) 24V DC Allowable Voltage Range 85 to 264V AC (U rating: 85 ~ 125V AC) 21.6 to 26.4V DC Rated Frequency 50/60 Hz (allowable range: 47 to 63 Hz) Inrush Current 10A (100V AC) 20A (200V AC) 10A Dielectric Strength (1 minute, 1 ma) Operating Temperature Storage Temperature Operating Humidity Atmosphere Pollution Degree Insulation Resistance Vibration Resistance (damage limits) Shock Resistance (damage limits) Terminal Style Mounting Power Consumption (approx.) Between intrinsically safe circuit and non-intrinsically safe circuit: V AC Between AC power and signal input: 1500V AC 20 to +60 C (no freezing) 20 to +60 C (no freezing) 45 to 85% RH (no condensation) 800 to 1100 hpa 2 (IEC60664) 10 MΩ minimum (500V DC megger, between the same poles as the dielectric strength) Panel mounting: 10 to 55 Hz, amplitude 0.75 mm (2 hours each on X, Y, Z) DI rail mounting: 10 to 55 Hz, amplitude 0.35 mm (2 hours each on X, Y, Z) Panel mounting: 500 m/s 2 (3 times each on X, Y, Z) DI rail mounting: 300 m/s 2 (3 times each on X, Y, Z) M3 screw terminal 35-mm-wide DI rail or panel mounting (M4 screw) 8.8 VA (EB3-S10SA at 200V AC) 5.2 W (EB3-S16CSD at 24V DC) ote: Illuminated switches, pilot lights, and miniature pilot lights are certified by TIIS and K only. Other certification organizations, such as U, regard these units as simple apparatus, and require no certification

21 EB3 Discrete Output Power Voltage 100 to 240V AC (U rating: 100 ~ 120V AC) 24V DC Accessories Connection to on-intrinsically Safe Circuit Screw Terminal Screw Terminal Connector Input Source Sink Source Sink ame Part umber Description DI Rail BAA1000 BA000 Part umbers Input Wiring Method Separate/Common Wiring Compatible umber of Channels Part umber Weight (g) 1 EB3-S01SA EB3-S02SA EB3-S03SA EB3-S05SA EB3-S06SA EB3-S08SA EB3-S10SA 360 Common Wiring Only 8 EB3-S08CSA 260 Separate/Common Wiring Compatible 1 EB3-S01KA EB3-S02KA EB3-S03KA EB3-S05KA EB3-S06KA EB3-S08KA EB3-S10KA 360 Common Wiring Only 8 EB3-S08CKA 260 Separate/Common Wiring Compatible Common Wiring Only Separate/Common Wiring Compatible Common Wiring Only 1 EB3-S01SD EB3-S02SD EB3-S03SD EB3-S05SD EB3-S06SD EB3-S08SD EB3-S10SD EB3-S08CSD EB3-S16CSD EB3-S01KD EB3-S02KD EB3-S03KD EB3-S05KD EB3-S06KD EB3-S08KD EB3-S10KD EB3-S08CKD EB3-S16CKD 350 Source 16 EB3-S16CSD-C 350 Common Wiring Only Sink 16 EB3-S16CKD-C 350 Aluminum (1m long, 10.5mm high) Steel (1m long, 7.5mm high) End Clip B6 Medium DI rail end clip OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 261

22 EB3 OI Touchscreens Internal Circuit Block Diagram AC Power Source Input 1 P2 2 P3 3 DC Power Sink Input 1 P2 2 P3 3 Connector Wiring Source Input Hazardous Area on-hazardous Area Green Yellow Yellow Yellow Green Yellow Yellow Yellow Green Yellow Yellow PCs ~ S1 C1 S2 C2 S3 C3 ~ + S1 C1 S2 C2 S3 C3 + ~ S1 S16 C1 C2 Dimensions (mm) Automation Software Terminal EB3 S01 EB3 S02 EB3 S03 EB3 S05 EB3 S06 EB3 S08C EB3 S08 EB3 S10 EB3 S16C Intrinsic Safety Side: ight Blue ø4.4 Power Supplies ø6 hole Communication on-intrinsic Safety Side: Yellow (4) Sensors Mounting Hole Hole ayout ayout (Screw (Screw Mounting) Mounting) 2-M4 tapped or 2-ø4.5 mounting holes 65 2-M4 tapped or 2-ø4.5 mounting holes 2-M4 tapped or 2-ø4.5 mounting holes 4-M4 tapped or 4-ø4.5 mounting holes

23 EB3 Connector (4) 6 EB3 S16C D ø ø4.5 holes 65 on-intrinsically Safe External Input Wiring Examples 6-channel Source 8-channel Common Wiring, Source (Ex.: EB3-S06SA) (Ex.: EB3-S08CSD) 100 to 240V AC 1 P2 2 P3 3 P4 4 P5 5 P S1 C1 S2 C2 S3 C3 S4 C4 S5 C5 S6 C6 16-channel Common Wiring, Source (Ex.: EB3-S16CSD) + 24V DC P2 P3 P4 P5 P6 P7 + 24V DC P8 1 2 P S1 S2 S3 S4 S5 S6 S7 S8 C1 C2 S9 S10 S11 S12 S13 S14 S15 S16 C3 C4 ote: Source input type can be connected to PC sink output type C terminal is the negative common line. All dimensions are in mm 4-M4 or 4-ø4.5 holes 97 Mounting Hole ayout P2 P3 P4 P5 P6 P7 P S1 S2 S3 S4 S5 S6 S7 S8 C1 C channel Common Wiring, Sink (Ex.: EB3-S16CKD) + 24V DC P2 P3 P4 P5 P6 Applicable Crimping Terminal 6 max. 3 max. ø3.2 min. 5.4 min. Solid Wire - Strip wire end 6 to 8 mm Stranded Wire - use a ferrule 6-channel Sink (Ex. EB3-S06KA) 100 to 240V AC P7 1 6 to 8 mm P2 2 P3 3 P4 4 P5 5 P S1 C1 S2 C2 S3 C3 S4 C4 S5 C5 S6 C6 P8 1 2 P S1 S2 S3 S4 S5 S6 S7 S8 C1 C2 S9 S10 S11 S12 S13 S14 S15 S16 C3 C4 ote: Sink input type can be connected to PC source output type C terminal is the positive common line. OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 263

24 EB3 Connector Wiring Terminal Arrangement OI Touchscreens EB3-S16CSD-C CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 S9 S10 S11 S12 S13 S14 S15 S16 C C S1 S2 S3 S4 S5 S6 S7 S8 C1 C2 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 COM +V 1 2 CHn Sn COM + Wiring Example with IDEC s MicroSmart PC Output Modules FC4A-T16K3 EB3-S16CSD-C FC4A-T16S3 EB3-S16CKD-C Terminal Output Input Terminal Terminal Output Input Terminal 20 Q0 S Q0 S Q10 S Q10 S9 19 EB3 PC 18 Q1 S Q1 S2 18 +V (C2) 17 Q11 S Q11 S10 17 PCs Automation Software + Internal Circuit EB3-S16CKD-C S1-S16 COM (C1) Power Supplies Sensors Communication Output Q0-Q15 COM CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 S9 S10 S11 S12 S13 S14 S15 S16 C C S1 S2 S3 S4 S5 S6 S7 S8 C1 C2 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 COM -V Internal Circuit 1 2 CHn Sn COM + 16 Q2 S Q12 S Q3 S Q13 S Q4 S Q14 S Q5 S Q15 S Q6 S Q2 S Q12 S Q3 S Q13 S Q4 S Q14 S Q5 S Q15 S Q6 S7 8 + Internal Circuit EB3 COM (C1) S1-S16 COM Output Q0-Q15 PC Internal Circuit 7 Q16 S Q7 S8 6 5 Q17 S COM COM 4 3 COM C 3 2 +V +V 2 7 Q16 S Q7 S8 6 5 Q17 S COM COM 4 3 COM C 3 2 V V 2 -V (C2) 1 +V C 1 1 V C 1 ote: The wiring in dashed line does not affect the operation of the EB3. Applicable connector is IDEC s JE1S-201. Output power for PC outputs is supplied by the EB3, therefore the PC output does not need an external power supply

25 EB3 Wiring Example of Intrinsically Safe External Outputs 1. Common Wiring (Maximum 16 circuits) (Buzzers cannot be wired in a common line.)* (+) ( ) (+) ( ) P2 S1 S1 S2 P2 S2 P3 S3 P3 S3 P4 S4 P4 S4 P5 S5 P5 S5 P6 S6 P6 S6 S7 S8 S7 S8 C1 C1 C2 2. Separate Wiring (+) ( ) S1 P7 P8 1 2 P C2 S9 S10 S11 S12 S13 S14 S15 S16 C3 C4 P7 P8 1 2 P P2 2 P3 3 C1 S2 C2 S3 S9 S10 S11 S12 S13 S14 S15 S16 C3 C4 C3 (+) ( ) 1 P2 2 P3 3 P4 4 P5 5 P6 6 S1 C1 S2 C2 S3 C3 S4 3. Wiring Illuminated Pushbuttons and Illuminated Selector Switches (A maximum of 16 channels of EB3 and EB3C can be wired to a common line.) (+) ( ) B1 B2 B3 S1 S2 S3 1 P2 2 P3 3 P4 4 P5 5 P6 6 S1 C1 S2 C2 S3 C3 S4 C4 S5 C5 S6 C6 (+) ( ) B1 B2 B3 C4 S5 C5 S1 S6 C6 (+) ( ) (+) ( ) (+) ( ) 1 P2 2 P3 3 S1 S1 C1 C1 S2 C2 S3 C3 1 P2 2 P3 3 1 P2 2 P3 3 P4 4 P5 5 P6 6 P7 7 P8 8 P A1 C1 A2 C2 A3 C3 A4 C4 A5 C5 A6 C6 A7 S2 C7 S2 C2 S3 C3 (+) ( ) (+) ( ) 1 P2 2 P3 3 P4 4 P5 5 P6 6 S1 C1 S2 C2 (+) ( ) S1 1 2 C1 C2 S3 C3 (+) ( ) 1 2 S1 C1 C2 S4 C4 (+) ( ) All output lines are wired to a common line inside the intrinsically safe equipment (one common line per intrinsically safe circuit) - DC input models only. All input lines are wired to a common line outside the intrinsically safe equipment (one common line per intrinsically safe circuit). S5 C5 S6 C6 1 P2 2 P3 3 P4 4 P5 5 P6 6 Each output line of the EB3 makes up one independent intrinsically safe circuit of a pilot light or buzzer. 1 2 S1 C1 C2 S1 C1 1 P2 2 P3 3 P4 4 P5 5 P6 6 P7 7 P8 8 P The following example illustrates the wiring for a total of 10 contacts used by three illuminated pushbuttons (B1 to B3) and three illuminated selector switches (S1 to S3). *This is permitted under TIIS approvals S1 A8 C1 C8 S2 A9 C2 S3 S3 C3 C9 A10 C10 S4 C4 S5 C5 S2 S6 C2 C6 S3 S7 C3 C7 S4 S8 C4 C8 S5 S9 C5 S6 C6 C9 S10 C10 (+) ( ) (+) ( ) 1 P2 2 P3 3 P4 4 P5 5 P6 6 P7 7 P8 8 P S1 C1 S2 C2 S3 C3 S4 C4 S5 C5 S6 C6 S7 C7 S8 C8 S9 C9 S10 C10 1 P2 2 P3 3 P4 4 P5 5 P6 6 P7 7 P8 8 P S1 C1 S2 C2 S3 C3 S4 C4 S5 C5 S6 C6 S7 C7 S8 C8 S9 C9 S10 C10 (+) ( ) (+) ( ) When using two or more EB3 s to set up one intrinsically safe circuit in the common wiring configuration, interconnect two neutral terminals (1 through 10) on each EB3 between adjacent EB3 s in a parallel. Diagram Symbols S1 S1 P2 S2 P2 S2 P3 S3 P3 S3 P4 S4 P4 S4 EB3P consisting of one enclosure P5 S5 P5 S5 P6 S6 P6 S6 One intrinsically safe circuit P7 S7 P7 S7 P8 1 2 S8 C1 S8 C1 C2 P8 1 2 One intrinsically safe circuit is a connection consisting of one or more illuminated units connected to a common line. C2 OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 265

26 EB3 Communication Sensors Power Supplies Automation Software PCs OI Touchscreens Recommended Connector Cable for Connector Types Description o. of Poles ength (m) Part umber Shape Applicable Type I/O Terminal Cable With Shield Without Shield Cable with Crimping Terminal 40-pin Cable for PC FC9Z-H A, FC9Z-H B Internal Connection IDEC Connector JE1S (Connection Side) FC9Z-H E4 Internal Connection IDEC Connector JE1S (Connection Side) 20 IDEC Connector JE1S (Connection Side) Y-shaped Compresion Terminal (Marking Tube umber) FC9Z-H050A20 1 FC9Z-H100A20 2 FC9Z-H200A20 3 FC9Z-H300A FC9Z-H050B20 1 FC9Z-H100B20 2 FC9Z-H200B20 3 FC9Z-H300B20 1 BX9Z-H100E4 2 BX9Z-H200E4 3 BX9Z-H300E4 1 BX9Z-H100B 2 BX9Z-H200B 3 BX9Z-H300B BX9Z-H B Internal Connection Connector A IDEC JE1S Fujitsu Connector FC-367J040-AU/F B A Connector B Connector A Connector B IDEC JE1S IDEC MicroSmart I/O Module IDEC MicroSmart I/O Module Screw Terminal Mitsubishi A Series Output Module (sink) EB3-S16CSD-C 266

27 Switches and Pilot Devices Switches and Pilot Devices General Specifications for Pilot ight, Illuminated Pushbutton, Illuminated Selector Switch, and Buzzer Operating Temperature Operating Humidity Dielectric Strength (1 ma, 1 minute) Insulation Resistance Pilot ight and Miniature Pilot ight Degree of Protection ens/illumination Color Intrinsic Safety Ratings and Parameters 20 to +60 C (no freezing) 45 to 85% RH (no condensation) EB3P: 1000V AC I: 500V AC (between intrinsically safe circuit and dead parts) 10 MΩ minimum (500V DC megger, between the same poles as the dielectric strength) IP65 (IEC60529) (except for terminals) EB3P-U/I: IP40 Pilot light: Amber, blue, green, red, white, yellow Miniature pilot light: Amber, green, red, white, yellow 1-channel Separate Wiring Maximum input voltage (Ui): 13.2V Maximum input current (Ii): 14.2 ma Maximum input power (Pi): 46.9 mw Internal capacitance (Ci): 2 nf Internal inductance (i): 5 µh 16-channel Common Wiring Maximum input voltage (Ui): 13.2V Maximum input current (Ii): ma Maximum input power (Pi): 750 mw Internal capacitance (Ci): 32 nf Internal inductance (i): 80 µh ote: Connect buzzers in separate wiring. Buzzers cannot be used in com mon wiring. Illuminated Switch Buzzer Degree of Protection Illumination Color Contact Voltage/Current Intrinsic Safety Ratings and Parameters IP65 (IEC60529) (except for terminals) EB3P-SAW**: IP54 Amber, blue, green, red, white, yellow 12V DC ±10%, 10 ma ±20% (when connecting to the EB3C) 16-channel Common Wiring Maximum input voltage (Ui): 13.2V Maximum input current (Ii): ma Maximum input power (Pi): 750 mw Internal capacitance (Ci): 32 nf Internal inductance (i): 80 µh IP20 (IEC60529) (except for terminals) Degree of Protection Sound Volume 75 db minimum (at 1 m) Sound Source Piezoelectric oscillator (continuous or intermittent) 1-channel Separate Wiring Maximum input voltage (Ui): 13.2V Intrinsic Safety Maximum input current (Ii): 14.2 ma Ratings and Maximum input power (Pi): 46.9 mw Parameters Internal capacitance (Ci): 260 nf Internal inductance (i): 80 mh Weight Part umbers for Pilot ights, Illuminated Pushbuttons, Illuminated Selector Switches, and Buzzers Unit Size Series 1 Shape Operation Mode Contact Ordering umber Pilot ight Miniature Pilot ight ø30 ø22 ø10 ø8 ø6 TW HW W UP Dome EB3P-A1-* Square EB3P-U3B-* Rectangular w/metal Bezel EB3P-U4-* Dome w/diecast Sleeve EB3P-AD1-* Flush EB3P-AW1-* Flush(Marking Type) EB3P-AW1B-* Dome EB3P-AW2-* Square Flush (Marking Type) EB3P-UW1B-* Round Flush EB3P-HW1-* Dome EB3P-HW2-* Square Flush EB3P-HW4-* Round EB3P-W1-* Square EB3P-W2-* Round w/ Square Bezel EB3P-W3-* Extended I-18-* Dome I-19-* Flush I-87-* Extended I-88-* Dome I-89-* Flush I-67-* Extended I-68-* Dome I-69-* 100g ens Color/ Illumination Color Code* A: Amber G: Green R: Red S: Blue W: White 5 Y: Yellow A: Amber G: Green R: Red W: White 5 Y: Yellow Operation OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 267

28 Switches and Pilot Devices OI Touchscreens Part umbers for Pilot ights, Illuminated Pushbuttons, Illuminated Selector Switches, and Buzzers, con t Unit Size Series 1 Shape Operation Mode Contact Ordering umber 2 Illumination ens Color/ Color Code* ø30 Extended Momentary 1O-1C EB3P-BA211-* Maintained 1O-1C EB3P-BAO211-* A: Amber G: Green R: Red S: Blue W: White 5 Y: Yellow Operation Communication Sensors Power Supplies Automation Software PCs Illuminated Pushbutton Illuminated Selector Switch 3 Buzzer ø22 TW HW W Mushroom Pushlock Turn Reset 1O-1C EB3P-BAV311-R Red only Extended Momentary 1O-1C EB3P-BAW211-* Maintained 1O-1C EB3P-BAOW211-* A: Amber G: Green R: Red S: Blue W: White 5 Y: Yellow Mushroom Pushlock Turn Reset 1O-1C EB3P-BAVW411-R Red only Round Round Square ø30 Round ø22 TW HW W Round Round ø30 Momentary 1O EB3P-BH1W110-* Maintained 1O EB3P-BHA1W110-* Momentary DPDT EB3P-B1W1C2-* Maintained DPDT EB3P-BA1W1C2-* Momentary DPDT EB3P-B2W1C2-* Maintained DPDT EB3P-BA2W1C2-* 2-position 1O-1C EB3P-SA211-* Maintained 3-position 2O EB3P-SA320-* Maintained 2-position 1O-1C EB3P-SAW211-* A: Amber Maintained G: Green 2-position, return from 1O-1C EB3P-SAW2111-* R: Red Spring return from right right S: Blue 3-position 2O EB3P-SAW320-* W: White 5 Y: Yellow Maintained 3-position, return from right 2O EB3P-SAW3120-* Spring return from right 3-position,return from left 2O EB3P-SAW3220-* Spring return from left 3-position,2-way return 2O EB3P-SAW3320-* 2-way spring return 2-position 1O-1C EB3P-SHW211-* Maintained 3-position 2O EB3P-SHW320-* Maintained Round 2-position DPDT EB3P-S1W2C2-* Maintained Round w/square Bezel 3-position DPDT EB3P-S3W3C2-* Maintained 1. Codes, TW, HW, W, and UP are the series names of IDEC s control units. 2. Specify a color code in place of *. 3. Above parts are recommended for EB3 barriers. However, none of these parts are U recognized. 4. Buzzers are not rated for Zone 0, but only Zones 1 and Use PW (pure white) ED for yellow lenses Accessory Continuous sound EB3P-ZU12C Intermittent sound EB3P-ZU12F ame Ordering umber Package Quantity Remarks ED amp EB9Z-DS1-* 1 Static Electricity EB9Z Polyester 20(W) x 6(H) mm Caution Plate Above part is recommended for EB3 barriers. However, this part is not U recognized. Approx. 3 Hz Specify a color code in place of * in the ordering number. A: amber, G: green, R: red, S: blue, W: white, PW: pure white (for yellow use PW with yellow lens) Use PW (pure white) ED for yellow lenses 268

29 Switches and Pilot Devices Pilot ights ø30 EB3P-A1 Terminal Cover: AP-PV (sold separately) M3 Terminal Screw 21.5 Panel Thickness 0.8 to ø22 EB3P-AW1 ø35 Terminal Cover (supplied) APS-PV Panel Thickness 1 to 6 M3.5 Terminal Screw ø24 ø ø22 EB3P-HW1/EB3P-HW2/EB3P-HW4 Terminal cover attached. Panel Thickness 0.8 to 6 M3.5 Terminal Screw Gasket ocking Ring X2 X Flush Dome ø30 EB3P-U4 Terminal Cover: AP-PV (sold separately) M3 Terminal Screw ø22 EB3P-AW1B Round/Dome Miniature Pilot ights (Terminal cover not available) ø10 I-18 + Terminal 7 ø8 I-89 + Terminal M10.0 Panel Thickness 0.6 to ø M8 P0.75 Panel Thickness 0.6 to ø8.1 ø ø29 ø10 I-19 + Terminal 7 ø6 I-67 Panel Thickness 0.8 to 4.5 Square M10.0 Panel Thickness 0.6 to 4 M6 P Terminal ø9.9 ø Panel Thickness 0.6 to 4 ø ø30 EB3P-AD Terminal Cover: APD-PV (sold separately) M3.5 Terminal Screw 29.8 Panel Thickness 0.8 to ø22 EB3P-AW2 M3.5 Terminal Screw ø24.8 ø35 Terminal Cover (supplied) APS-PV Panel Thickness 1 to 6 ø23.6 ø ø40 ø22 EB3P-W1/EB3P-W2/EB3P-W3 Terminal cover attached. Gasket 7.2 ocking Ring ø8 I-87 + Terminal 6.1 ø6 I M3 Terminal Screw 7.7 M8 P0.75 Panel Thickness 0.6 to 4 M6 P Terminal ø Panel Thickness 0.6 to 4 ø ø30 EB3P-U3B Terminal Cover: AP-PV (sold separately) M3 Terminal Screw ø22 EB3P-UW1B M3.5 Terminal Screw Panel Thickness 0.8 to Terminal Cover (supplied) APS-PV Panel Thickness 1 to 6 9 ø Marking Plate: 22 Panel Thickness 0.8 to 6 Round ø8 I-88 + Terminal 6.1 ø6 I-69 Square 25.8 M8 P0.75 Panel Thickness 0.6 to 4 M6 P Terminal ø Panel Thickness 0.6 to 4 ø6 ø OI Touchscreens PCs Automation Software Power Supplies Sensors Communication IDEC (4332) USA & Canada 269

30 Switches and Pilot Devices OI Touchscreens Illuminated Pushbuttons ø30 EB3P-BA211/BAO211 Terminal cover: -V4 (2 pcs.) (sold separately) M3 Terminal Screw M3.5 Terminal Screw Panel Thickness 0.8 to 7.5 ø30 EB3P-BAV311-R Terminal cover: -V4 (2 pcs.) (sold separately) M3 Terminal Screw M3.5 Terminal Screw Panel Thickness 0.8 to 7.5 ø24 ø35 ø40 ø PCs ø22 EB3P-BAW211/BAOW211 Terminal cover attached. M3.5 Terminal Screw Adjustment Ring Panel Thickness 1 to 6 30 ø24 ø22 EB3P-BAVW411-R Terminal cover attached. M3.5 Terminal Screw Adjustment Ring Panel Thickness 1 to 6 30 Reset 75 ø22 EB3P-BH1W110/BHA1W110 Terminal cover attached. M3.5 Terminal Screw ocking Ring ever Stop Panel Thickness 0.8 to 6 OCK ø24 ø29 37 ø ø Automation Software ø22 EB3P-B1W1C2/BA1W1C2 Terminal cover: W-V2M (sold separately) M3 Terminal Screw 23.2 R18 OCK Panel Thickness 0.8 to 6 ø22 EB3P-B2W1C2/BA2W1C2 Terminal cover: W-V2M (sold separately) M3 Terminal Screw 23.2 R18 OCK Panel Thickness 0.8 to 6 Power Supplies 25.4 Illuminated Selector Switches ø30 EB3P-SA211/EB3P-SA320 Terminal cover: -V4 (2 pcs.) (sold separately) M3 Terminal Screw M3.5 Terminal Screw Panel Thickness 0.8 to ø ø22 EB3P-SAW*** Terminal cover attached M3.5 Terminal w Panel Thickness 1 to 6 All dimensions in mm. ø25 ø35 ø40 ø24 ø Sensors ø22 EB3P-SHW211/EB3P-SHW320 Terminal cover attached M3.5 Terminal Screw Panel Thickness 0.8 to 6 OCK ø29 ø22 EB3P-S1W2C2/EB3P-S3W3C2 Terminal cover: W-V2M (sold separately) M3 Terminal Screw R18 OCK Panel Thickness 0.8 to 6 ø Communication 25 Buzzer ø30 EB3P-ZU12C/ZU12F Terminal cover: AZ-V5 (sold separately) 29.4 EB9Z-DS Panel Thickness 0.8 to M3.5 Terminal Screw ø50 Illumination Color IDEC Exi 10.6 Intrinsic Safety Identification: ight Blue Illumination color is marked on the terminal

Barriers. Discrete Output Barrier

Barriers. Discrete Output Barrier EB3 EB3 Discrete Output 126 types of pilot lights and buzzers can be connected. Illuminated pushbuttons and illuminated selector switches can be connected by combining with the EB3C discrete input barrier.

More information

Barriers. EB3N Discrete Input Barrier with Redundant Output

Barriers. EB3N Discrete Input Barrier with Redundant Output EB3N Discrete Input Barrier with Redundant Output s Build a safety system in an explosive atmosphere. Key features: Safety Performance Performance level e Category 4 [Exia] II C Ensures safety and machine

More information

Barriers. Intrinsically Safe: EB3C Discrete Input Barriers

Barriers. Intrinsically Safe: EB3C Discrete Input Barriers Sensors Power Supplies Automation Software PLCs OI Touchscreens Intrinsically Safe: Discrete Input Key features: Applicable Standards IEC60079 compliant Dry-contact switches can be connected to the 8-

More information

Input contacts can be used in any explosive gas and Zone 0/Class I Div. 1 areas. Input Wiring Method

Input contacts can be used in any explosive gas and Zone 0/Class I Div. 1 areas. Input Wiring Method Relay Barriers Input contacts can be used in any explosive gas and Zone 0/Class I Div. 1 areas. Relay Barrier: [Exia] II C Explosion Switch (EB9Z-A): Exia II CT6 protection Switch (EB9Z-A1): Exia II BT6

More information

Intrinsically Safe Explosion Proof Barriers

Intrinsically Safe Explosion Proof Barriers Safety Intrinsically Safe Explosion Proof For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos &

More information

EB3C Relay Barriers EB3L Lamp Barriers EB3N Safety Relay Barriers

EB3C Relay Barriers EB3L Lamp Barriers EB3N Safety Relay Barriers EB3C Relay Barriers EB3 amp Barriers EB3 Safety Relay Barriers EB3C Relay Barriers EB3 Safety Relay Barriers EB3 amp Barriers Intrinsically Safe Explosion-proof System In order to establish an intrinsically

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

Communication & Networking

Communication & Networking MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators

More information

Communications & Networking

Communications & Networking 8-Point Source Input & 8-Point Transistor Sink Output odule () Key features include: Communicate with network 8-point source input and 8-point sink output module Removable terminal blocks Use as remote

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Control Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. Switching Power Supplies The offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. With U 508 isting, additional savings in space and cost can be realized

More information

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W Selection Guide Selection Guide PS5R Slim Line PS5R PS3L Operator Interfaces Communication & Networking PLCs NEW Models Appearance Automation Software Page 107 113 118 Housing Plastic Metal Mounting DIN

More information

AS-Interface Safety at Work

AS-Interface Safety at Work Safety Emergency Stop Switches... 478 Operating Instructions... 482 www.idec.com/safety AS-Interface Safety at Work Light Curtains Table of Contents LED Lighting - Pg. 1 Automation & Sensing - Pg. 21 Safety

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications RSC Series RSC Series Solid State Relays Key features of the RSC series include: Slim design allows for DIN rail or panel mounting Built-in heat sink maximizes current output capability Epoxy-free design

More information

Series Panel Mounted Control Devices

Series Panel Mounted Control Devices E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Timers. GT5Y Series ON Delay Timers. ±3% maximum (over 10 to 50 C, reference temperature 20 C) Setting Error. ±10% maximum

Timers. GT5Y Series ON Delay Timers. ±3% maximum (over 10 to 50 C, reference temperature 20 C) Setting Error. ±10% maximum GT5Y GT5Y Series ON Delay Key features: 4PDT, 3A or DPDT, 5A contacts 4 time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED indicators Uses the same

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: 21/64 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action

More information

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit. Selectable safety circuits The light curtain unit has a built-in monitoring function for external devices (such as fused relay monitoring). This supports the construction of light curtain peripheral safety

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines! 1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible

More information

One step ahead in performance and mounting ease

One step ahead in performance and mounting ease 95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~

More information

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC

More information

Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours

Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours GT3W Key features: Sequential start, sequential interval, on-delay, recycler, and interval ON timing functions 2 time settings in one timer 8 selectable operation modes on each model Mountable in sockets

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost. 811 Compact & ow Price Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.176~ guide... P.781~ General precautions... P.179~ PHOTO PHOTO MEASURE

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices LED and Incandescent ilot Lights (Sub-Assembled) Removable Terminal* + Operator + Lamp + Lens = Completed Unit * Removable terminals are applicable for CB terminated types only. art Numbers: ilot Light

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

GT3F Series True OFF Delay Timers

GT3F Series True OFF Delay Timers TF Series TF Series True OFF Delay Key features of the TF series include: Mountable in sockets or flush panel True power OFF-delay up to 10 minutes No external control switch necessary Available with reset

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

FX1N JAPANESE SPECIFICATION UNITS

FX1N JAPANESE SPECIFICATION UNITS FX1N JAPANESE SPECIFICATION UNITS HARDWARE MANUA JY997D071A This manual contains safety information, associated manual listings, specifications and terminal layouts and wiring for Japanese specification

More information

DIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C

DIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C RTE Series DIN Rail Mounting Accessories Part Numbers: DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Applicable Hold-Down Springs Style Appearance Use with Part No. Appearance

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

T imers Timers Selection Guide Timing Diagrams Overview RTE Series Analog Timers Instructions onlinecomponents.com IDEC.

T imers Timers Selection Guide Timing Diagrams Overview RTE Series Analog Timers Instructions onlinecomponents.com IDEC. Industrial Automation Catalog Section - U906 imers Selection uide iming Diagrams Overview RE Series Analog imers Instructions imers For up-to-date information, or to request a full copy of this catalog,

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation

More information

E2Q4 Square Proximity Sensor

E2Q4 Square Proximity Sensor Inductive Square Slim, compact size M2 Plug-in connection Integrated short circuit and reverse polarity protection Active face positioning: Y-axis 5, X-axis 90 incremets Ordering Information DC type Connection

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.

More information

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product

More information

RM84 miniature relays

RM84 miniature relays RM84 miniature relays RM84 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 DC1 DC13 Motor load acc. to

More information

Relays & Sockets RR Series Power Relays. Part Number Selection

Relays & Sockets RR Series Power Relays. Part Number Selection RR Series Power Relays Key features: SPDT through PDT, A contacts Midget power type relays Available in pin and blade terminal styles. Options include an indicator, check button for test operations and

More information

Communications & Networking

Communications & Networking is a type of field bus that is primarily intended to be used to control sensors and actuators. is a network system that is compatible with the IEC62026 standard. A master device can communicate with slave

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability 82 PHOTO PHOTO Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.86~ Sensor selection guide... P.757~ General precautions...

More information

Optimum sensing capability for LCD manufacturing

Optimum sensing capability for LCD manufacturing SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent

More information

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D D080D INSTRUCTI MANUAL Flammable Liquid Presence Detector Interface Relay Output DINRail Model D080D D080 Flammable Liquid Presence Detector Interface Relay Output ISM00559 Characteristics General Description:

More information

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable 44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in

More information

S8VE (60/90/120/180/240-W Models)

S8VE (60/90/120/180/240-W Models) Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

Suitable for detecting transparent films or transparent bottles

Suitable for detecting transparent films or transparent bottles Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16

More information

MACX MCR-EX-SD LP(-SP)

MACX MCR-EX-SD LP(-SP) Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices ø22mm - LW Series Oiltight LED and Incandescent Illuminated ushbuttons (Assembled) art Numbers: LW1L/LW2L Illuminated ushbuttons (LED and Incandescent) art Number Contact Style Contact Momentary Maintained

More information

SolConeX extra-low voltage flange socket

SolConeX extra-low voltage flange socket SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3

More information

Twido Programmable Controllers Discrete I/O Modules

Twido Programmable Controllers Discrete I/O Modules Twido Programmable Controllers Discrete I/O Modules Hardware Guide 03/2007 www.telemecanique.com 2 Table of Contents Safety Information....................................5 About the Book.......................................9

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

FS1A Safety Controller

FS1A Safety Controller FS1A ler New (11 logics), introducing new logics! circuit logics compliant international standards ISO 1389-1 PLe International Standard Compliant Cost Saving No Programming Required Compact 2 logics 11

More information

MACX MCR-EX-SL-NAM-R(-SP)

MACX MCR-EX-SL-NAM-R(-SP) Intrinsically safe NAMUR isolating amplifier with relay output INTERFACE Data sheet 03463_en_00 PHOENIX CONTACT - 08/2008 Description The NAMUR MACX MCR-EX-SL-NAM-R(-SP) isolating amplifier has been designed

More information

RTE Series Analog Timers. UL Listed File No. E kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)

RTE Series Analog Timers. UL Listed File No. E kPa to 110kPa (Operating), 70kPa to 110kPa (Transport) Analog Key features of the RE series include: 0 time ranges and 0 timing functions ime delays up to 600 hours Space-saving package High repeat accuracy of ± 0.% ON and timing LED indicators Standard 8-

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

MACX MCR-EX-SL-NAM-2RO(-SP)

MACX MCR-EX-SL-NAM-2RO(-SP) Intrinsically safe NAMUR isolating amplifier with two relay outputs INTERFACE Data sheet 03465_en_00 PHOENIX CONTACT - 08/008 Description The NAMUR MACX MCR-EX-SL-NAM-RO(-SP) isolating amplifier has been

More information

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global 8 PHOTO PHOTO MEASURE Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F- Glossary of terms... P.576~ panasonic.net/id/pidsx/global guide... P.78~ General

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in 1 Ultra-small Micro Photoelectric PM- SERIES Related Information General terms and conditions... F-17 Glossary of terms / General precautions... P.19~ / P.10 Amplifier Built-in selection guide... P.1~

More information

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2 Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering

More information

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs 19 Ultra-small Micro Photoelectric Sensor PM- SERIES Related Information General terms and conditions...p.1 Glossary of terms / General precautions...p.98~ / P.98~ Amplifier Built-in Sensor selection guide...p.11~

More information

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect VX Miniature Snap Action Switch Compact snap action switch with low force operation Internal mechanism assures outstanding contact reliability Models available for micro load up through 5 Amps ROHS Compliant

More information

HR1S-AC Safety Relay Modules

HR1S-AC Safety Relay Modules HRS-AC Relay Modules Transistor output provided. Removable terminal block (HRS-AC52P) allows for easy module replacement. Fault diagnosis function with dual safety circuits. Internal relay operations can

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

MINI MCR-SL-CVS NC

MINI MCR-SL-CVS NC Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

FS1A Safety Controller

FS1A Safety Controller FS1A ler New (11 logics), introducing 4 new logics! circuit logics compliant international standards ISO 13849-1 PLe International Standard Compliant Cost Saving No Programming Required Compact 24 logics

More information

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

Analog Voltage Combination Module

Analog Voltage Combination Module Analog Voltage Combination Module T1F-8AD4DA-2 8-channel analog voltage input 4-channel analog voltage output The combination 8-in and 4-out voltage module uses a T1K-8B or T1K-8B-1 base, which is purchased

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays FEATURES/BENEFITS Zero-cross models with system diagnostics Very low zero-cross turn-on voltage Input and output protection and control LED standard IP20 protection by flaps on terminals With double removable

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver C 57W 8-5mA flexc lp ACED series Product description Built-in constant current ED Driver ew version DC operating with E marking Adjustable output current between 8 and,5 ma Max. output power 57

More information