JUNE 2013

Size: px
Start display at page:

Download "JUNE 2013"

Transcription

1 JUNE 2013 Technical application guide BackLED S, M, L Plus BackLED MB and LB

2 CONTENT Content 1. Product overview BackLED modules BackLED S Plus BA01SB BackLED M Plus BA03MA BackLED L Plus BA03LA BackLED MB BB03MA and BackLED LB BB03LA 6 6. Application overview Selection table for BackLED in light boxes Selection table for BackLED in channel letters Product/application matrix Luminance selection aid BackLED mounting profi le BA03-MP Technical data at a glance 8 7. Thermal properties Casing temperature at the T c point Product overview OPTOTRONIC power supplies Measuring the T c temperature Dimming matrix Power output rating Installation instructions For channel letters System combinations LED modules power supplies For BackLED L Plus (with mounting profi le) For BackLED S Plus termination unit System information Nomenclature and marking LED designer Electrical properties Standards and regulations for LED modules and power supplies Electrical connections Electrical connectors General Overview of connectors Notes General notes Safety information Tools and links 29 Disclaimer: All the information in this guide has been produced with the utmost care. However, OSRAM does not accept any liability for possible errors, changes and/or omissions. Please check to see whether a more recent version of this guide is available, or get in touch with your sales contact. 2

3 PRODUCT OVERVIEW BackLED MODULES 1. Product overview BackLED modules 1.1. BackLED S Plus BA01SB General features One BackLED S Plus module chain comprises 90 individual white LED modules (blue version: 45 modules) Specially designed optics with Flat-Ray technology for best application efficiency One LED per module Full encapsulation of the LED modules with ingress protection IP66 Light colors: white 6500 K, 4000 K, 3000 K, blue Fully integrated heat sink Mounting holes and pre-mounted adhesive tape allow for easy mounting Optimal operation on OPTOTRONIC 12 V power supplies (15 W, 30 W, 60 W, 120 W) BackLED S Plus BackLED S Plus 7 Applications Signage and illuminated advertising Backlighting of small and flat channel letters BackLED S Plus termination unit BA01SB-TERM Termination unit for the operation of either individual LED modules or groups of two LED modules Suitable only for BackLED S Plus (white and blue) Special rugged encapsulation for long-term outdoor use in closed light boxes Type of protection: IP66 Ambient temperature range (T a ): C Operating temperature at the T c point: max. 75 C Storage temperature range: C ø3.8 All figures in mm Light distribution 30 Function of termination unit BackLED S Plus module chains are divided into operating units of three LED modules. For the operation of a single LED module or a group of two LED modules, the BackLED S Plus termination unit is required. BackLED S Plus termination unit ø White/red If a termination unit is used, only a dimming range from 100 % to 30 % is permitted White White/black BackLED S Plus termination unit suitable only for BackLED S Plus! All figures in mm 3

4 PRODUCT OVERVIEW BackLED MODULES 1.2. BackLED M Plus BA03MA General features One BackLED M Plus module chain comprises 40 individual LED modules Specially designed optics with Flat-Ray technology for best application efficiency Three LEDs per module Full encapsulation of the LED modules with ingress protection IP66 Light colors: white 6500 K, 4000 K, 3000 K, red, orange Fully integrated heat sink Mounting holes and pre-mounted adhesive tape allow for easy mounting Optimal operation on OPTOTRONIC 12 V power supplies (15 W, 30 W, 60 W, 120 W) New cutting resolution = one module Accessory: BackLED mounting profile BA03-MP for simplified installation in light boxes BackLED M Plus BackLED M Plus ø Applications Signage and illuminated advertising Backlighting of standard-size channel letters Backlighting of flat light boxes All figures in mm 55 Light distribution 4

5 PRODUCT OVERVIEW BackLED MODULES 1.3. BackLED L Plus BA03LA General features One BackLED L Plus module chain comprises 32 individual LED modules Specially designed optics with Flat-Ray technology for best application efficiency Three LEDs per module Full encapsulation of the LED modules with ingress protection IP66 Light colors: white 6500 K, 4000 K, 3000 K Fully integrated heat sink Mounting holes and pre-mounted adhesive tape allow for easy mounting Optimal operation on OPTOTRONIC 12 V power supplies (15 W, 30 W, 60 W, 120 W) New cutting resolution = one module Accessory: BackLED mounting profile BA03-MP for simplified installation in light boxes BackLED L Plus BackLED L Plus ø Applications Signage and illuminated advertising Backlighting of large and deep channel letters Backlighting of light boxes All figures in mm Light distribution 5

6 PRODUCT OVERVIEW BackLED MODULES 1.4. BackLED MB BB03MA and BackLED LB BB03LA General features Flexible chain comprising 36 LED (BackLED LB) or 40 LED (BackLED MB) modules Full encapsulation of the LED modules (including LEDs) for durable use in outdoor signage applications Accessory: BackLED mounting profile BA03-MP for simplified installation in light boxes BackLED MB ø4.2 All figures in mm Applications Signage and illuminated advertising BackLED MB: Backlighting of standard-size channel letters BackLED LB: Backlighting of large and deep channel letters Backlighting of light boxes Light distribution BackLED LB 10.6 ø BackLED MB 76 All figures in mm Light distribution BackLED LB 6

7 PRODUCT OVERVIEW BackLED MODULES 1.5. BackLED mounting profile BA03-MP General features Universally applicable mounting profile for single or double-sided light boxes Overall length: 2000 mm Integrated 50-mm mounting grid for simple positioning of the LED modules Integrated fixing option for cables Benefits Can be easily shortened to any length Quick and easy mounting of the profile with self-tapping screws or pop rivets Quick and simple snap-in fixing of the LED modules, no tools required Robust aluminum profile Applications Signage and illuminated advertising Backlighting of single and double-sided light boxes BackLED mounting profile suitable only for BackLED M/L Plus and BackLED MB/LB! BackLED mounting profi le Total length: 2000 mm All figures in mm Slot holes for the mounting of the profile on the rear board or side board of the light box. Holes for the easy installation of a mounting grid. The constant hole spacing of 50 mm provides consistent pitches of LED modules without measuring. Square holes for simple fixing of electrical cables with cable ties. Embossings/edges for the easy click-in of the individual LED modules (Click & Play). 7

8 PRODUCT OVERVIEW BackLED MODULES 1.6. Technical data at a glance Product reference Product number Light color No. of LED modules per chain (no. of LEDs per module) Rated output per chain (per module) [W] 1) Luminous flux per chain (per module) [lm] 1) Beam angle [ ] 1) Color temperature [K] 1) Wavelength [nm] 1) Standard pack/ pcs. BackLED S Plus 2) BA01SB- W4F-765 BA01SB- W4F-840 BA01SB- W4F-830 BA01SB- B White 90 (1) 28.8 (0.32) 2790 (31) chains White 90 (1) 28.8 (0.32) 2340 (26) chains White 90 (1) 28.8 (0.32) 2070 (23) chains Blue 45 (1) 14.4 (0.32) 270 (6) chains BackLED S Plus termination unit BA01SB- TERM BackLED M Plus BA03MA- W4F-765 BA03MA- W4F-840 BA03MA- W4F-830 BA03MA- R2 BA03MA- O White 40 (3) 28.8 (0.72) 3000 (75) chains White 40 (3) 28.8 (0.72) 2520 (63) chains White 40 (3) 28.8 (0.72) 2200 (75) chains Red 40 (3) 28.8 (0.72) 720 (18) chains Orange 40 (3) 28.8 (0.72) 960 (24) chains BackLED L Plus BA03LA- W4F-765 BA03LA- W4F-840 BA03LA- W4F White 32 (3) 57.6 (1.8) 4800 (150) chains White 32 (3) 57.6 (1.8) 4000 (125) chains White 32 (3) 57.6 (1.8) 4000 (125) chains BackLED MB BB03MA- W4F White 40 (3) 28.8 (0.72) 3000 (75) chains BackLED LB BB03LA- W4F White 36 (3) 52.6 (1.56) 5000 (125) chains BackLED mounting profile 3) L x W x H [mm] Mounting grid pitch [mm] BA03-MP x 20 x Modules are perfectly matched to 12 V OSRAM OPTOTRONIC power supplies (see chapter 3. System combinations LED modules power supplies). The maximum overall lengths of the entire chains are: BackLED S Plus: m (BA01SB-B3 with blue light color: 5.62 m); BackLED M Plus: 8.00 m; BackLED L Plus: 9.60 m; BackLED MB: 8.00 m; BackLED LB: 9.00 m. For current photometric data and important safety, installation and application information, see 1) In view of the complex manufacturing process for light-emitting diodes, the specified typical values for the technical LED parameters are merely statistical values that do not necessarily correspond to the actual technical parameters of an individual product; individual products may vary from the typical values. 2) Minimum operating unit after cutting the chain is one module or two modules with termination unit (two termination units at each chain included in delivery, also available as accessory) and three modules without termination unit. 3) Can only be used with BackLED M/L Plus and BackLED MB/LB. 8

9 PRODUCT OVERVIEW OPTOTRONIC POWER SUPPLIES 2. Product overview OPTOTRONIC power supplies 12 V range for BackLED S, M, L Plus and BackLED MB, LB Power supply OT 15/ /12 P OT 30/ /12 P OT 60/ /12 P OTe 60/ /12 E OT 120/ /12 P AC voltage, nominal V AC V AC V AC V AC V AC Output voltage 12.5 V DC ± 0.5 V 12.5 V DC ± 0.5 V 12.5 V DC ± 0.5 V 12.5 V DC ± 0.5 V 12.5 V DC ± 0.5 V Protection class and IP rating (type of protection) Class II, IP66 Class II, IP66 Class II, IP67 Class I, IP64 Class I, IP67 Maximum load 15 W 30 W 60 W 60 W 120 W Power factor > 0.5 full 230 V AC > 0.95 full 230 V AC > 0.90 half 230 V AC > 0.98 full 230 V AC > 0.93 half 230 V AC > 0.95 full 230 V AC > 0.90 half 230 V AC > 0.98 full 230 V AC > 0.95 half 230 V AC Ambient temperature range -25 to +55 C -25 to +55 C -25 to +55 C -25 to +55 C -25 to +55 C Surge capability L-N: 4 kv L-N: 4 kv L-N: 3 kv L-N: 2 kv, L/N PE: 3 kv L-N: 3 kv, L/N PE: 6 kv No-load proof Yes Yes Yes Yes Yes Overload/short-circuit protection Automatic, reversible Automatic, reversible Automatic, reversible Automatic, reversible Automatic, reversible Overheating protection Automatic, reversible Automatic, reversible Automatic, reversible Automatic, reversible Automatic, reversible Cable length Input side/output side ~ 300 mm/~ 300 mm Input side/output side ~ 300 mm/~ 300 mm Input side/output side ~ 500 mm/~ 500 mm Input side/output side ~ 300 mm/~ 300 mm Input side/output side ~ 500 mm/~ 500 mm Dimensions (L x W x H) 237 x 20 x 22 mm 220 x 40 x 22 mm 180 x 50 x 34 mm 241 x 43 x 30 mm 250 x 60 x 39 mm Conformity CE, ENEC, CB CE, ENEC, CB CE, ENEC, CB CE CE, ENEC, CB Product number

10 PRODUCT OVERVIEW OPTOTRONIC POWER SUPPLIES OT 15/ /12 P All figures in mm OT 30/ /12 P All figures in mm OT 60/ /12 P All figures in mm OTe 60/ /12 E All figures in mm OT 120/ /12 P All figures in mm

11 PRODUCT OVERVIEW OPTOTRONIC POWER SUPPLIES 2.1. Dimming matrix Output voltage Maximum output power Dimming devices OT DIM 1)2) OTi DALI DIM 1)2) OTi DALI DIM LI 1)2)3) OPTOTRONIC EAN V/max. 5 A max. 60 W 12 V/max. 4 A max. 48 W 1 10 V DALI DALI Non-dim version OT 15/ /12 P V 15 W OT 30/ /12 P V 30 W OT 60/ /12 P V 60 W OTe 60/ /12 E V 60 W OT 120/ /12 P V 120 W ) For outdoor applications, the dimming device has to be protected by an appropriate IP box. 2) If a termination unit is used, only a dimming range from 100 % to 30 % is permitted. 3) For the OTi DALI DIM LI, OSRAM recommends the use of a protective housing such as the OSRAM OUTKIT (EAN: ) Power output rating The Φ-U c characteristic curve in the diagram below shows a general definition of the power output depending on the control voltage of an OT DIM or OT DALI DIM (LI) dimming device Power output rating [%] Control voltage U c [V] Operation without applied control voltage (shorted) Operation without applied control voltage (floating) 0 % power output 100 % power output 11

12 SYSTEM COMBINATIONS LED MODULES POWER SUPPLIES 3. System combinations LED modules power supplies Maximum number of LED chains and modules per control gear Product BackLED S Plus BackLED M Plus BackLED L Plus Chains Modules Chains Modules Chains Modules OT 15/ /12 P 1/2 45 1/2 20 1/4 8 OT 30/ /12 P /2 16 OT 60/ /12 P OTe 60/ /12 E OT 120/ /12 P Maximum number of LED chains and modules per control gear Product BackLED S Plus blue (BA01SB-B3) BackLED MB (BB03MA-W4F-765) BackLED LB (BB03LA-W4F-765) Chains Modules Chains Modules Chains Modules OT 15/ /12 P /2 20 1/4 9 OT 30/ /12 P /2 18 OT 60/ /12 P OTe 60/ /12 E OT 120/ /12 P BackLED S Plus Installation with more than 90 modules (one full chain, white) on one OPTOTRONIC 120 W or OPTOTRONIC 60 W requires a power feed to the center or a splitting of the power feed to contact groups of LED modules. Installation with more than 45 modules (one full chain, blue) on one OPTOTRONIC 120 W, OPTOTRONIC 60 W or OPTOTRONIC 30 W requires a power feed to the center or a splitting of the power feed to contact groups of LED modules. BackLED M Plus Installation with more than 40 modules (one full chain) on one OPTOTRONIC 120 W or OPTOTRONIC 60 W requires a power feed to the center or a splitting of the power feed to contact groups of LED modules. BackLED L Plus Installation with more than 32 modules (one full chain) on one OPTOTRONIC 120 W requires a power feed to the center or a splitting of the power feed to contact groups of LED modules. BackLED MB Installation with more than 40 modules (one full chain) on one OPTOTRONIC 120 W or OPTOTRONIC 60 W requires a power feed to the center or a splitting of the power feed to contact groups of LED modules. BackLED LB Installation with more than 36 modules (one full chain) on one OPTOTRONIC 120 W requires a power feed to the center or a splitting of the power feed to contact groups of LED modules. 12

13 SYSTEM INFORMATION 4. System information 4.1. Nomenclature and marking BackLED Plus for white light BA: BackLED Plus, BB: BackLED 01: 1 LED per LED module 03: 3 LEDs per LED module S: Small M: Medium L: Large A: Version A W4F: White/4th generation/fine binning 765: CRI + CCT: CRI K 830: CRI + CCT: CRI K BA 01MA-W4F-765 (white) 840: CRI + CCT: CRI K BackLED Plus for colored light BA: BackLED Plus, BB: BackLED 01: 1 LED per LED module 03: 3 LEDs per LED module S: Small M: Medium L: Large A: Version A R2: Red/2nd generation O2: Orange/2nd generation BA 01 S A-B2 (colors) B2: Blue/2nd generation 13

14 SYSTEM INFORMATION BackLED S Plus termination unit BA: BackLED Plus 1 termination unit per 1 or 2 LED module(s) S: Small B: Version B TERM: Termination unit BA 01SB-TERM OPTOTRONIC power supplies OT: OPTOTRONIC 15: 15 W output power 30: 30 W output power 60: 60 W output power 120: 120 W output power Input voltage range: V Output voltage: 12 V P: Protect; IP65 OT 60/ /12 P 14

15 SYSTEM INFORMATION BackLED S Plus XXX XXXXX 12 V DC XXX Module code CCT Voltage Date code BackLED S Plus termination unit BA01SB-TERM* XXX t c =75 C max. IP66 E Product description T C IP Date code CE mark BackLED M Plus XXX XXXXX XXX 0.72 W/module 12 V DC Module code CCT Date code Power Voltage BackLED L Plus XXX XXXXX XXX 1.8 W/module 12 V DC Module code CCT Date code Power Voltage 15

16 SYSTEM INFORMATION BackLED MB XXX XXXXX XXX 1.56 W/module 12 V DC Module code CCT Power Voltage Date code BackLED LB XXX XXXXX XXX 1.56 W/module 12 V DC Module code CCT Date code Power Voltage OPTOTRONIC power supplies Input voltage Output voltage Standards and regulations OSRAM ident code Line current, nominal Power factor IP rating European norms electrical certification Casing temperature at the T c point Primary side Input side Conformity mark of the European Community Max. casing temperature in the case of fault Secondary side Output side 16

17 ELECTRICAL PROPERTIES 5. Electrical properties 5.1. Electrical connections We recommend the following cable lengths and cable cross-sections (see page 18) for the electrical connections between the LED chains and the connection to the OPTOTRONIC power supplies. BackLED S Plus (white) BackLED S Plus (blue) Maximum secondary cable length [m] W 45 modules 1/2 chain W 66 modules 3/4 chain 28.8 W 90 modules 1 chain AWG16/1.23 mm 2 AWG14/2.08 mm 2 AWG13/2.62 mm mm mm 2 Maximum secondary cable length [m] W 24 modules 1/2 chain W 36 modules 3/4 chain 14.4 W 48 modules 1 chain AWG16/1.23 mm 2 AWG14/2.08 mm 2 AWG13/2.62 mm mm mm 2 LED module power [W] LED module power [W] BackLED M Plus BackLED L Plus Maximum secondary cable length [m] W 30 modules 3/4 chain 30 W 40 modules 1 chain LED module power [W] AWG20/0.57 mm 2 AWG18/0.79 mm 2 AWG16/1.23 mm 2 AWG14/2.08 mm 2 AWG13/2.62 mm mm mm 2 Maximum secondary cable length [m] W 8 modules 1/4 chain 30 W 16 modules 1/2 chain 45 W 24 modules 3/4 chain 60 W 32 modules 1 chain AWG16/1.23 mm 2 AWG14/2.08 mm 2 AWG13/2.62 mm mm mm 2 LED module power [W] BackLED MB BackLED LB Maximum secondary cable length [m] 100 AWG16/1.23 mm W 10 modules 1/4 chain 14.4 W 20 modules 1/2 chain 21.6 W 30 modules 3/4 chain 28.8 W 40 modules 1 chain AWG14/2.08 mm 2 AWG13/2.62 mm mm mm 2 LED module power [W] Maximum secondary cable length [m] 70 AWG16/1.23 mm W 9 modules 1/4 chain 28.1 W 18 modules 1/2 chain W 27 modules 3/4 chain 56.2 W 36 modules 1 chain AWG14/2.08 mm 2 AWG13/2.62 mm mm mm 2 LED module power [W] 17

18 ELECTRICAL PROPERTIES Power supply LED module LED module LED module Max. secondary length = power supply first LED module + wire extension LED module LED module +... Recommended cable cross-sections Product Type of cable AWG A [mm 2 ] Recommended cable cross-section for connecting an LED chain to other LED modules [mm²] BackLED S Plus BackLED M Plus BackLED L Plus BackLED MB BackLED LB Multi-wire (stranded) Multi-wire (stranded) Multi-wire (stranded) Multi-wire (stranded) Multi-wire (stranded) Electrical connectors General Electrical connectors are manufactured in many different versions, including screw-type terminals, wire nuts, plug connectors and joining terminals (connectors). Use only appropriate cables and connectors to link the LED modules to the OPTOTRONIC power supplies. Electrical terminals must not be used where they may be directly exposed to the weather without adequate protection. For outdoor applications, plug connectors (without moisture protection) must therefore be protected by IP junction boxes or light boxes. Disclaimer: In terms of electromagnetic compatibility (EMC), the maximum permitted cable length is 10 meters (please refer to the technical data sheet of the applied OSRAM OPTOTRONIC power supply). Users are responsible to ensure EMC. Channel letter BackLED module Wrong: The terminal is on the fl oor Please note: We recommend to use the LED modules only in combination with OSRAM OPTOTRONIC power supplies. The maximum secondary length is the maximum cable length between the power supply and the first LED module of a chain plus the wire extensions between the LED modules (see illustration above). Channel letter BackLED module Correct: The terminal is raised by bending both cables up If you are using plug connectors that do not have IP protection (moisture protection), make sure that the openings are always pointing downwards. 18

19 ELECTRICAL PROPERTIES Overview of connectors Among others, the following standard terminals are suitable for the electrical connections between the LED chains and the connections to the OPTOTRONIC power supplies: Manufacturer Reference Type of cable* Maximum outer diameter AWG cable cross-section Operating temperature Special property BackLED Plus BackLED S M L MB LB 3M UY2 Single-wire 0.155" (3.94 mm) AWG26 18 ( mm 2 ) ºC ( ºF) Sealed against moisture 3M UR2 Single-wire 0.082" (2.08 mm) AWG26 18 ( mm 2 ) ºC ( ºF) Sealed against moisture 3M 314 Single-wire/ multi-wire 0.082" (2.08 mm) AWG22 14 ( mm 2 ) Max. 105 ºC (221 ºF) Sealed against moisture 3M UB Single-wire 0.050" (1.27 mm) AWG26 18 ( mm 2 ) ºC ( ºF) Sealed against moisture WAGO Series 222 Single-wire/ multi-wire AWG28 12 ( mm 2 ) Max. 85 ºC (185 ºF) PHOENIX JBC 2.5/X Single-wire/ multi-wire AWG20 14 ( mm 2 ) * Not all connectors are suitable for multi-wire and fine-wire conductors. In some cases, therefore, end sleeves must be provided. Please read the manufacturer s instructions. 19

20 APPLICATION OVERVIEW 6. Application overview 6.1. Selection table for BackLED in light boxes 1) Depth of light box [mm] Single-sided light boxes BackLED M Plus 125 2) 200 2) 200 2) 200 2) BackLED L Plus 210 2) 275 2) 300 2) 300 2) 300 2) BackLED MB 100 2) 150 2) 175 2) 200 2) 200 2) BackLED LB 175 2) 200 2) 225 2) 250 2) 250 2) Double-sided light boxes BackLED M Plus 125 2) 160 2) 200 2) 200 2) 200 2) BackLED L Plus 210 2) 275 2) 300 2) 300 2) 300 2) BackLED MB 100 2) 150 2) 175 2) 200 2) 200 2) BackLED LB 175 2) 200 2) 225 2) 6.2. Selection table for BackLED in channel letters 1) Depth of channel letter [mm] BackLED S Plus ) 95 2) 125 2) 125 2) BackLED M Plus 95 2) 125 2) 200 2) 200 2) 200 2) BackLED L Plus 210 2) 275 2) 300 2) 300 2) 300 2) BackLED MB 100 2) 150 2) 175 2) 200 2) 200 2) BackLED LB 175 2) 200 2) 225 2) 250 2) Optimal product performance at maximum distance between module centers Good product performance at maximum distance between module centers Good product performance at reduced distance between module centers Limited performance risk of non-uniform backlighting Limited performance reduced effi ciency 1) The selection can vary depending on the special characteristics of the illuminated sign, e.g. concerning front material or type of application. 2) Maximum distance between module centers in mm. 20

21 APPLICATION OVERVIEW 6.3. Product/application matrix Application Light boxes Channel letters Type Single-sided Double-sided Height [m] Small ( ) Small to medium ( ) Large (> 2.0) Small ( ) Small to medium ( ) Large (> 2.0) All sizes All sizes All sizes All sizes Depth [mm] BackLED S Plus x x BackLED M Plus x x x x x BackLED L Plus x x x x x BackLED MB x x x x x x BackLED LB x1 x1 x2 x2 x1 x x x1 x2 applicable applicable, depth 150 mm applicable, depth 300 mm 6.4. Luminance selection aid Recommended luminance L (cd/m 2 ) in relation to different color applications Red Orange Yellow Green Blue White L low L medium L high These recommendations apply to typical diffuse light-emitting surfaces. The table only serves as a recommendation. The user should by all means test his own configuration to adapt it to his specific requirements. 21

22 THERMAL PROPERTIES 7. Thermal properties 7.1. Casing temperature at the T c point The casing temperature is the temperature at a defined point on the LED casing, the T c point. The maximum T c temperature is the highest permitted temperature that may occur at the T c point under the planned ambient and operating conditions in the thermally steady state. If the maximum permitted T c temperature is exceeded, the LED module may go into a state in which the load limits on the module (LED, casing, chip, encapsulation materials) are reached. A thermal link between BackLED (Plus) modules and the mounting surface is not absolutely essential. Thermo-wire NiCr Ni Mini connector K 1000±15 All figures in mm Temperature sensors Description Temperature range Length [mm] Diameter [mm] T90 Powerful sensor with a magnetic holding force of 90 N Tube sensor with fl exible hook-and-loop tape -30 to +550 C x to +100 C 2000 For m 25 mm 40 x 25 mm Velcro fastener for mm 2 m Foil sensor, self-adhesive -50 to +250 C x Flexible Tefl on wire L 1.2 x 0.8 mm 10 x 20 mm Possible suppliers of such temperature sensors include OMEGA: and B+B Thermo-Technik: 22

23 THERMAL PROPERTIES 7.2. Measuring the T c temperature The indicated lifetime can only be achieved if the permitted operating temperatures at the T c point are maintained. After the LED modules have been installed in a channel letter, the T c temperature must be measured under the planned ambient and operating conditions in the thermally steady state. To do this, attach a temperature sensor to the T c point with suitable adhesive (cyanoacrylate-free). The illustrations below show the T c reference point, marked by a small circle on the front/back of the LED modules and on the side of the termination unit. BackLED S Plus BackLED M Plus BackLED L Plus Front T c Back T c Front T c BackLED S Plus termination unit BackLED MB BackLED LB Side T c Back T c Back T c Permitted T c temperatures Operating temperature at the T c point* [ C] BackLED S Plus BackLED S Plus termination unit max. 75 BackLED M Plus (white) BackLED M Plus (R2/O2) BackLED L Plus BackLED MB BackLED LB * If the maximum temperature limits are exceeded, the lifetime of the module will be greatly reduced or the module may be destroyed. The temperature of the LED module at the T c point should be measured in the thermally steady state by means of a temperature sensor or temperature-sensitive sticker in accordance with EN For the precise position of the T c point, see the illustrations above. 23

24 INSTALLATION INSTRUCTIONS 8. Installation instructions 8.1. For channel letters 1. Clean the surface of the back panel board of the channel letter with a solvent (e.g. ethanol). 2. Screw the power supply into the channel letter. The power supply has pre-drilled fixing holes. 3. Remove the insulation from the cable ends of the LED modules and the power supply using a suitable tool. 4. Connect the secondary side of the power supply to the LED modules. 5. Now remove the protective film from the adhesive pad on the back of the LED modules. 6. Place the LED module in the appropriate position in the channel letter and carefully press it down. 7. The LED modules must also be screwed in place so they can better withstand transportation or vibration. 8. Connect the primary side of the power suppy to the power cables See the general safety instructions on page 28 24

25 INSTALLATION INSTRUCTIONS 8.2. For BackLED L Plus (with mounting profile) 1. Clean the inside of the mounting profile with a solvent (e.g. ethanol) to provide the best possible adhesion surface for the LED module. 2. Now remove the protective film from the adhesive pad on the back of the LED modules. 3. Snap the LED modules (BackLED L Plus) into the mounting profile. 4. Form a cable loop between the individual LED modules and fix it to the mounting profile with a cable tie to avoid shadows. 1 2 Please note: All exposed metal parts (such as the mounting profile) must be grounded in accordance with the latest safety requirements. Please also read the general safety instructions on page 28. 3a 3b 4a 4b 8.3. For BackLED S Plus termination unit BackLED S Plus module chains are divided into operating units of three LED modules. For the operation of a single LED module or a group of two LED modules, the BackLED S Plus termination unit is required. Connect the termination unit to the last LED module or the last two LED modules of the module chain. Please connect the wires accordingly: white/red to white/red, white to white and white/black to white/black. Please note: The termination unit is only suitable and necessary for BackLED S Plus modules! 25

26 LED designer 9. LED designer Now with new functions for even greater ease of use By entering just a few data in the user-friendly LED designer online software, you can automatically see which components and how many of these components are needed for your particular application and also the correct arrangement of the LED modules. To make it even easier for you to enter this data, you can download our checklist. LED designer has been upgraded with the following new functions: When you select a text with a defined font, you will now instantly see a preview. Entering and evaluating the luminance value (brightness) has been simplified and made more transparent. From now on, calculations for the LED modules and power supplies can be made for each individual letter. The type and number of power supplies can be selected either manually or automatically. 26

27 STANDARDS AND REGULATIONS FOR LED MODULES AND POWER SUPPLIES 10. Standards and regulations for LED modules and power supplies The OSRAM LED modules are perfectly matched to the electronically stabilized OSRAM OPTOTRONIC power supplies, which are protected against short-circuit, overload and overtemperature. OSRAM LED modules and OPTOTRONIC power supplies comply with all the relevant standards (see below) and ensure safe and reliable operation. LED modules Photobiological safety IEC Infl ammability IEC Protection class EN Safety requirements EN 62031, IEC Radio interference EN EMC/immunity EN CE Yes OPTOTRONIC power supplies Safety EN Radio interference EN Immunity EN Harmonic content EN CE Yes 27

28 NOTES 11. Notes General notes Each LED module is equipped with a pre-mounted double-sided adhesive tape which allows for optional or additional mounting. Due to varying properties of adherends and multiple external influences during the operation of the modules, OSRAM assumes no liability and provides no guarantee for a permanent adherence of the modules to the surface. OSRAM recommends fixation of the modules by means of suitable screws. Safe operation is ensured only if the LED chains are connected in parallel. Connecting the LED chains in series is NOT recommended. Unbalanced voltage drops may lead to serious overloads and destruction of individual modules. Make sure to take suitable ESD (electrostatic discharge) precautions when installing the modules. If drivers other than OSRAM OPTOTRONIC power supplies are used, the output voltage must be 12.5 V ± 0.5 V for 12 V DC to ensure safe operation of the modules. The LED chains must only be shortened by cutting the connecting cables between the LED modules. The LED chains must not be used where they may be directly exposed to the weather without adequate protection. In outdoor applications, the LED chains must therefore be protected by suitable housings or covers. The LED chains cannot be operated in or under water Safety information Before you start assembly, please read this information carefully. Caution: There is a risk of an electric shock. Disconnect the power supply before installing or maintaining the product. To avoid mechanical damage due to vibration, the LED modules must be connected flush with the mounting surface. Avoid exposing the equipment to strong vibrations. The LED modules, including the power supply, may only be installed by a qualified electrician in accordance with all the valid regulations and standards. Ensure that the poles are connected correctly. No light will be emitted if the polarity is incorrect. In this case, simply reverse the polarity. Recommended properties of light boxes To ensure uniform illumination, a reflective matt white surface is generally recommended for all internal frame walls and back panels for light boxes. 28

29 TOOLS AND LINKS 12. Tools and links The following materials and tools relating to signage are available on various web pages: BackLED Plus BackLED MB and LB BoxLED Back Plus BoxLED Side and BoxLED Side Plus Technical application guides Product data sheets > > LED designer for applications with channel letters LED designer Checklist signage application > OPTOTRONIC Product data sheets Technical guide Operating instructions > Note: Please also read the product data sheets for the BackLED Plus and BackLED MB/LB modules. These data sheets contain important information regarding safety and installation. The latest data sheets are available at Please also read the OPTOTRONIC technical guide and product data sheets, which are available at For conditions and details, go to Others Technical application guide ESD protection for LED systems Technical application guide IP codes in accordance with IEC Signage brochure including pocket guide New standards for LED control gear 29

30 OSRAM GmbH Head Office Marcel-Breuer-Strasse Munich Germany Phone +49 (0) Fax +49 (0) /13 Subject to change without notice. Errors and omissions excepted.

MAY 2013 Technical application guide BoxLED Side and BoxLED Side Plus

MAY 2013 Technical application guide BoxLED Side and BoxLED Side Plus www.osram.com/boxled MAY 2013 Technical application guide BoxLED Side and BoxLED Side Plus CONTENT Content 1. Product overview BoxLED Side and BoxLED Side Plus 3 1.1. General features 3 1.2. Applications

More information

Turns innovation into fascination signage with OSRAM LEDs

Turns innovation into fascination signage with OSRAM LEDs www.osram.com/signage Turns innovation into fascination signage with OSRAM LEDs New 03 One-stop solution provider for signage One-stop solution provider for signage Thanks to an efficient overall system,

More information

BoxLED ECO M Plus G3. Product family datasheet. LED modules for light advertising and backlighting

BoxLED ECO M Plus G3. Product family datasheet. LED modules for light advertising and backlighting BoxLED ECO M Plus G3 LED modules for light advertising and backlighting Areas of application _ Signage and illuminated advertising _ Illumination of single and double-sided light boxes _ Permanent outdoor

More information

LINEARLIGHT FLEX ADVANCED LF06A TECHNICAL DATASHEET

LINEARLIGHT FLEX ADVANCED LF06A TECHNICAL DATASHEET www.osram.com/flex LINEARLIGHT FLEX ADVANCED LF06A TECHNICAL DATASHEET Key Features & Benefits Linear separable LED strip on flexible printed circuit board with self-adhesive back High quality single PCB

More information

No. of. Voltage. Power

No. of. Voltage. Power Value Flex Eco VFEG1 Data Sheet Benefits Energy saving low-power LED flexible strip for decorative, shelf and hospitality lighting. Self-adhesive tape on the back for easy and fast installation. Consistent

More information

) Forward voltage (V f. Typ. Max. Typ. [V] [V]

) Forward voltage (V f. Typ. Max. Typ. [V] [V] LZ-492A Linear LED Module, LZ Series High value 490 mm linear module, high efficacy up to max. 164 lm/w at Tc = 65 C Homogenous light distribution, pitch only 15.3 mm between single LEDs Accurate initial

More information

DRAGON-X. Technical Operating Data DATA SHEET

DRAGON-X. Technical Operating Data DATA SHEET DATA SHEET DRAGON-X DX1 RoHS Compatible Benefits Featuring High Flux GOLDEN DRAGON LED on Metal-Core PCB Thermally managed for almost immediate application Secondary Optics Options of 12 o, 30 o and 60

More information

LX-562A. Linear LED Module, LX Series. 450 ma, 62.7 V. Electrical specifications. Lifetime specifications. Operating Conditions and Characteristics

LX-562A. Linear LED Module, LX Series. 450 ma, 62.7 V. Electrical specifications. Lifetime specifications. Operating Conditions and Characteristics LX-562A Linear LED Module, LX Series High lumen output 560 mm linear module, very high efficacy up to max. 179 lm/w at Tc = 65 C Extremely homogenous light distribution, pitch only 6,4 mm between single

More information

HPML AD G13B Street Lighting High Power Modular Lamp Constant Current

HPML AD G13B Street Lighting High Power Modular Lamp Constant Current HPML AD G13B Street Lighting High Power Modular Lamp Constant Current Datasheet The HPML AD is a high power LED module with integrated heat sink for optimal thermal management and tailored optical design.

More information

L-iC-282. Tunable White Linear LED Module, L-iC Series. 450 ma, 14.9 V. Electrical specifications. Lifetime specifications

L-iC-282. Tunable White Linear LED Module, L-iC Series. 450 ma, 14.9 V. Electrical specifications. Lifetime specifications L-iC-282 Tunable White Linear LED Module, L-iC Series 280 mm Tunable White module, adjustable colour temperature between 2700K and 6500 K High efficacy up to 165 lm/w at Tc = 50 C Accurate initial colour

More information

ALULED IP66/IP V System WHITE, BLUE AND RGB LED MODULES IN FLAT ALUMINIUM PROFILE ALULED IP66/IP67

ALULED IP66/IP V System WHITE, BLUE AND RGB LED MODULES IN FLAT ALUMINIUM PROFILE ALULED IP66/IP67 ALULED IP66/IP67 WHITE, BLUE AND RGB LED MODULES IN FLAT ALUMINIUM PROFILE ALULED IP66/IP67 is ideal for outdoor protected applications under humid conditions (excluding direct UV exposure) and the slim

More information

) Forward voltage (V f. Typ. Typ. Typ. Max. Typ. Typ. Typ. [K] [lm] [lm] [V] [V] [lm/w] [lm/w] Operating Tc. current Temp

) Forward voltage (V f. Typ. Typ. Typ. Max. Typ. Typ. Typ. [K] [lm] [lm] [V] [V] [lm/w] [lm/w] Operating Tc. current Temp Linear LED Module, LS20 Series Slim 280 mm linear module, high efficacy up to 182 lm/w at Tc = 25 C Narrow width of 20 mm to suit various applications Homogenous light distribution, 30 LED packages with

More information

) Forward voltage (V f. Typ. Typ. Typ. Max. Typ. Typ. Typ. [K] [lm] [lm] [V] [V] [lm/w] [lm/w] Operating Tc. current Temp

) Forward voltage (V f. Typ. Typ. Typ. Max. Typ. Typ. Typ. [K] [lm] [lm] [V] [V] [lm/w] [lm/w] Operating Tc. current Temp Linear LED Module, LS20 Series Slim 140 mm linear module, high efficacy up to 182 lm/w at Tc = 25 C Narrow width of 20 mm to suit various applications Homogenous light distribution, 15 LED packages with

More information

Duris E5 PowerFlex LED Strips 25mm LED Pitch

Duris E5 PowerFlex LED Strips 25mm LED Pitch Duris E5 PowerFlex LED Strips 25mm LED Pitch ILX-E525-xx08-6000-SD2xx Product Overview The PowerFlex range are densely populated, high bright, flexible LED strips using the Osram Duris E5 LED at its heart.

More information

LED MODULES FOR MAINS VOLTAGE

LED MODULES FOR MAINS VOLTAGE LED MODULES FOR MAINS VOLTAGE DRIVER-ON-BOARD TECHNOLOGY LED MODULES READYLINE S With so-called Driver-on-Board technology (DoB), the control gear unit is directly integrated into the LED module, which

More information

CCT (K) BL G > BL G >

CCT (K) BL G > BL G > www.osram.com 770 lm, 1100 lm on 280 mm 1550 lm, 2200 lm on 560 mm 4400 lm on 1120 mm Features efficacy: up to 151 lm/w Color temperature: 3000 K, 4000 K, 6500 K Luminous flux: 770 lm, 1100 lm on 280 mm

More information

OTi DALI 75/ /700 D LT2 UF L

OTi DALI 75/ /700 D LT2 UF L OTi DALI 75/220 240/700 D LT2 UF L OPTOTRONIC Intelligent Ultraflat Dimmable DALI Areas of application _ Linear lighting for office, education, industry, storage areas and retail _ Installation in emergency

More information

OSLON IR 72 PowerFlood

OSLON IR 72 PowerFlood OSLON IR 72 PowerFlood ILF-IO72-xxxx-SD40 series Product Overview At the heart of each Flood are 72 OSRAM IR OSLON Black Series which is today s smallest infrared LED with more than one watt of optical

More information

Colour Luminous flux Φv Forward voltage Power consumption Tc= 65 C Tc= 25 C Tc= 65 C Tc= 65 C Tc= 65 C

Colour Luminous flux Φv Forward voltage Power consumption Tc= 65 C Tc= 25 C Tc= 65 C Tc= 65 C Tc= 65 C LS-282A Linear LED Module, LS Series Gen 2, high efficacy up to 163 lm/w Homogenous light distribution, 11.5 mm pitch between LEDs Accurate colour matching (SDCM), 3-step MacAdam High colour rendering

More information

LED LINE CSP TUNEABLE

LED LINE CSP TUNEABLE LED LINE CSP TUNEABLE L28/56 W4 LED LINE CSP TUNEABLE L28/56 W4 WU-M-522 / -523 Typical Applications Built-in luminaires/general illumination Office lighting Retail, corridor and shelf lighting T5/T8 replacement

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

Colour Luminous flux Φv Forward voltage Power consumption Tc= 65 C Tc= 25 C Tc= 65 C Tc= 65 C Tc= 65 C

Colour Luminous flux Φv Forward voltage Power consumption Tc= 65 C Tc= 25 C Tc= 65 C Tc= 65 C Tc= 65 C LS-562A Linear LED Module, LS Series Gen 2, high efficacy up to 163 lm/w Homogenous light distribution, 11.5 mm pitch between LEDs Accurate colour matching (SDCM), 3-step MacAdam High colour rendering

More information

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-542-G (270X540) LED MODULES FOR OFFICE LIGHTING WU-M-542-G

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-542-G (270X540) LED MODULES FOR OFFICE LIGHTING WU-M-542-G LED LIGHT PANEL SMD WU-M-542-G (270X540) LED LIGHT PANEL SMD LED MODULES FOR OFFICE LIGHTING WU-M-542-G Typical Applications Built-in luminaires/general illumination Office lighting, especially grid luminaires

More information

LED LINE SMD LIGHTBAR

LED LINE SMD LIGHTBAR LED LINE SMD LIGHTBAR WU-M-594 LED LINE SMD LIGHTBAR WU-M-594 Typical Applications Built-in luminaires/general illumination: Office lighting Retail lighting T5/T8 replacement as built-in module Furniture

More information

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-520 (250X250) WU-M-537 (270X270) LED MODULES FOR OFFICE LIGHTING

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-520 (250X250) WU-M-537 (270X270) LED MODULES FOR OFFICE LIGHTING LED LIGHT PANEL SMD WU-M-520 (250X250) WU-M-537 (270X270) LED LIGHT PANEL SMD LED MODULES FOR OFFICE LIGHTING WU-M-520/-537 Typical Applications Built-in luminaires/general illumination Office lighting,

More information

Dragon Oval 72 LED PowerFlood White

Dragon Oval 72 LED PowerFlood White Dragon Oval 72 LED PowerFlood White ILF-GO72-ULWH-SD401 Product Overview z Very powerful, low profile LED light engine z Oval photometrics pattern z Available in 6500K white z Even lighting over illuminated

More information

LED LIGHT PANEL QUADRANT SMD

LED LIGHT PANEL QUADRANT SMD LED LIGHT PANEL QUADRANT SMD WU-M-573 LED LIGHT PANEL QUADRANT SMD LED MODULES FOR HIGH-END RESIDENTIAL LIGHTING WU-M-573 Typical Applications Built-in luminaires/general illumination Large round ceiling

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

Datasheet. Dragon1IR PowerStars. LED Solutions. ILH-ID01-xxxx-SC201-xx series. Product Overview. Applications. Technical Features:

Datasheet. Dragon1IR PowerStars. LED Solutions. ILH-ID01-xxxx-SC201-xx series. Product Overview. Applications. Technical Features: Datasheet Osram Oslon LEDs employed Dragon1IR PowerStars LED Solutions ILH-ID01-xxxx-SC201-xx series Product Overview Dragon1IR PowerStars employ the new Osram Opto Semiconductors Dragon Infrared LEDs.

More information

LED MODULES FOR MAINS VOLTAGE

LED MODULES FOR MAINS VOLTAGE LED MODULES FOR MAINS VOLTAGE DRIVER-ON-BOARD TECHNOLOGY LED MODULES READYLINE C Built-in LED modules with integrated driver for direct connection to mains voltage With so-called Driver-on-Board technology

More information

Duris P5 32 Strip Deep Blue

Duris P5 32 Strip Deep Blue Duris P5 32 Strip Deep Blue ILS-P532-0300-DEBL-SC201-W2. Product Overview At the heart of each Duris P5 Strip are 32 Duris P5 family LEDs from OSRAM Opto Semiconductors. These are new low and mid-power

More information

OSLON IR 17 PowerFlood

OSLON IR 17 PowerFlood OSLON IR 17 PowerFlood ILF-IO17-xxxx-SC201 Product Overview At the heart of each Flood are 17 OSRAM IR OSLON Black Series which is today s smallest infrared LED with more than one watt of optical power.

More information

DUALdrive AC, 50W, DALI-2, 2 control channels, constant current, 2x 55V outputs, long metal, side feed

DUALdrive AC, 50W, DALI-2, 2 control channels, constant current, 2x 55V outputs, long metal, side feed 50W DALI-2 'Dim to Dark' LED Driver DUALdrive DUALdrive is perfect for dynamic white lighting applications or for luminaires that combine task and ambient lighting. DUALdrive excels in configurability

More information

LED LINE SMD EASY L14/28/56 W2

LED LINE SMD EASY L14/28/56 W2 LED LINE SMD EASY L14/28/56 W2 350 lm, 700 lm, 1400 lm LED LINE SMD EASY L14/28/56 W2 350 lm, 700 lm, 1400 lm WU-M-622, WU-M-601/602, WU-M-603/604 Typical Applications Built-in luminaires/general illumination

More information

Bridgelux Vero 10 Array Series

Bridgelux Vero 10 Array Series Bridgelux Vero 10 Array Series Product Data Sheet DS30 BXRC-27x1000 30x1000 35x1000 40x1000 50x1000 Introduction Vero Vero represents a revolutionary advancement in chip on board (COB) light source technology

More information

LED LINE SMD KIT GEN. 3

LED LINE SMD KIT GEN. 3 LED LINE SMD KIT GEN. 3 WU-M-480/-481-S WU-M-501/-502-S LED LINE SMD KIT GEN. 3 WU-M-480/-481-S and WU-M-501/-502-S Typical Applications Built-in luminaires/general illumination Office lighting Retail,

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

LED LINE SMD SLIM GEN. 2

LED LINE SMD SLIM GEN. 2 LED LINE SMD SLIM GEN. 2 LED LIGHTING MODULES WITH COVER LED LINE SMD SLIM GEN. 2 Lighting modules with cover Consisting of one energy-efficient LED Line SMD Slim, a thermo-conductive resin adhesive tape

More information

LED LINE SMD KIT 3R CSP TUNEABLE

LED LINE SMD KIT 3R CSP TUNEABLE LED LINE SMD KIT 3R CSP TUNEABLE L28/56 W5.5 LED LINE SMD KIT 3R CSP TUNEABLE WU-M-567 / -568 Typical Applications Built-in luminaires/general illumination Office lighting Retail, corridor and shelf lighting

More information

Bridgelux Vero 18 Array Series

Bridgelux Vero 18 Array Series Bridgelux Vero 18 Array Series Product Data Sheet DS32 BXRC-27x4000 30x4000 35x4000 40x4000 50x4000 Introduction Vero Vero represents a revolutionary advancement in chip on board (COB) light source technology

More information

LED LINE SMD KIT 3R GEN. 3

LED LINE SMD KIT 3R GEN. 3 LED LINE SMD KIT 3R GEN. 3 WU-M-526-S (280 MM) WU-M-536-S (566 MM) LED LINE SMD KIT 3R GEN. 3 WU-M-526-S / WU-M-536-S Typical Applications Built-in luminaires/general illumination Office lighting Retail,

More information

Bridgelux Vero 13 Array Series. Product Data Sheet DS31

Bridgelux Vero 13 Array Series. Product Data Sheet DS31 Bridgelux Vero 13 Array Series Product Data Sheet DS31 BXRC-27x2000 30x2000 35x2000 40x2000 50x2000 Introduction Vero Vero represents a revolutionary advancement in chip on board (COB) light source technology

More information

50W 0-10V LED Driver with Smooth Dimming to 1%

50W 0-10V LED Driver with Smooth Dimming to 1% 50W 0-10V LED Driver with Smooth Dimming to 1% ECOdrive Programmable digital ECOdrive LED driver providing standard LED fixtures with the smoothest flicker-free dimming to 1% light output, delivering value

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

VALUE Flex Protect 1200S

VALUE Flex Protect 1200S VALUE Flex Protect 1200S Linear LED modules for flexible and individualized lighting solutions Areas of application _ Wet or damp areas _ General illumination _ Hospitality _ Display cabinet lighting _

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

LED INDUSTRY KIT. LED Industry Kit LED Modules for Industry Lighting WU-M-564 LED INDUSTRY KIT WU-M-564

LED INDUSTRY KIT. LED Industry Kit LED Modules for Industry Lighting WU-M-564 LED INDUSTRY KIT WU-M-564 LED Modules for Industry Lighting LED INDUSTRY KIT WU-M-564 LED INDUSTRY KIT WU-M-564 Typical Applications Built-in luminaires/general illumination Industry lighting for: Production halls Warehouses Lighting

More information

FLEXESSORIES SLIMCONNECT SYSTEM 08 G2 TECHNICAL DATASHEET

FLEXESSORIES SLIMCONNECT SYSTEM 08 G2 TECHNICAL DATASHEET www.osram.com/flex FLEXESSORIES SLIMCONNECT SYSTEM 08 G2 TECHNICAL DATASHEET Enjoy full flexibility in lighting design. Connect easily modules without any need of tools. The SLIMCONNECT SYSTEM is made

More information

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable

More information

LFP200C -G3-RGB-06. Product datasheet. LINEARlight Colormix Flex Protect Flexible colored / color change LED modules

LFP200C -G3-RGB-06. Product datasheet. LINEARlight Colormix Flex Protect Flexible colored / color change LED modules LFP200C -G3-RGB-06 LINEARlight Colormix Flex Protect Flexible colored / color change LED modules Areas of application _ Facade accent lighting _ Effect lighting in architecture _ Edge coupling _ Path lighting

More information

OSLON 1 PowerStar IR. ILH-IO01-xxxx-SC201-xx Series. Product Overview. Applications. Technical Features

OSLON 1 PowerStar IR. ILH-IO01-xxxx-SC201-xx Series. Product Overview. Applications. Technical Features OSLON 1 PowerStar IR ILH-IO01-xxxx-SC201-xx Series Product Overview At the heart of each PowerStar is an OSRAM IR OSLON Black Series LED, which is today s smallest infrared LED with more than one watt

More information

LINEAR LED BUILT-IN MODULES

LINEAR LED BUILT-IN MODULES LINEAR LED BUILT-IN MODULES T5/T8 REPLACEMENT LUGA LINE RX GEN. 2 LED MODULES COB FOR LINEAR LIGHTING DML068***GR (280 mm) DML028***GR (93 mm) Typical Applications Built-in luminaires/general illumination

More information

Product Data Sheet DS32 BXRC-27x x x x x4000

Product Data Sheet DS32 BXRC-27x x x x x4000 Bridgelux Vero 18 Array Series Product Data Sheet DS32 BXRC-27x4000 30x4000 35x4000 40x4000 50x4000 Introduction Vero Vero represents a revolutionary advancement in chip on board (COB) light source technology

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

PrevaLED Core Z3 for Spot & Downlighting

PrevaLED Core Z3 for Spot & Downlighting www.osram.com/prevaled-core preliminary information PrevaLED Core Z3 for Spot & Downlighting Product information Sept 2013 Upgrade of PrevaLED Core Z2 in price, performance and ease of use What we keep

More information

LED FlatPanel Gen. 2 DALI

LED FlatPanel Gen. 2 DALI LED FlatPanel Gen. 2 DALI ULTRA FLAT LIGHT PANEL LED Recessed Mounted FlatPanels The use of state-of-the-art LED technology in conventional office and hall illumination provides a lot of advantages like

More information

TM42SQ12XX-2X2. Constant Current LED Square Module

TM42SQ12XX-2X2. Constant Current LED Square Module TM42SQ12XX2X2 Constant Current Square Module High Density, high brightness chip array for use in Class 2 square applications Constant current for maximum efficacy Available in standard CCT's Dimmable when

More information

SIGNAL OSLON 1 PowerStar

SIGNAL OSLON 1 PowerStar SIGNAL OSLON 1 PowerStar ILH-SO01-####-SC2#1- Product Overview At the heart of each PowerStar is an OSLON Signal ThinGan (UX:3) LED. OSLON SSL can be driven up to 1000mA. OSLON Signal LEDs support cutting

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

OSLON IR 27 PowerFlood

OSLON IR 27 PowerFlood OSLON IR 27 PowerFlood ILF-IO27-xxxx-SC201 series Product Overview At the heart of each PowerFlood are 27 OSRAM IR OSLON Black Series which is today s smallest infrared LED with more than one watt of optical

More information

LED LINE SMD EASY L28/56 W2

LED LINE SMD EASY L28/56 W2 LED LINE SMD EASY L28/56 W2 700 lm, 1400 lm LED LINE SMD EASY L28/56 W2 700 lm, 1400 lm WU-M-601/602, WU-M-603/604 Typical Applications Built-in luminaires/general illumination Office lighting Retail,

More information

FLEXESSORIES SLIMCONNECT SYSTEM 08 G2 TECHNICAL DATASHEET

FLEXESSORIES SLIMCONNECT SYSTEM 08 G2 TECHNICAL DATASHEET www.osram.com/flex FLEXESSORIES SLIMCONNECT SYSTEM 08 G2 TECHNICAL DATASHEET Enjoy full flexibility in lighting design. Connect easily modules without any need of tools. The SLIMCONNECT SYSTEM is made

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

Specification Data Sheet

Specification Data Sheet Specification Indoor Light : T8T Series Standard Standard Specification Data Sheet T8 Series ( Standard ) Product Picture : T8T-4ft Features 3 Years Warranty Specified Beam Angle CE / UL / DLC / RoHS Certificated

More information

LED-Strip B12. Product Sheet

LED-Strip B12. Product Sheet LED-Strip B12 Product Sheet schnick-schnack-systems Introduction features System compatible with other series from Schnick-Schnack-Systems Free patch, colour change and scroll text control software Made

More information

LED LINEAR ALLROUND GEN. 3

LED LINEAR ALLROUND GEN. 3 LED LINEAR ALLROUND GEN. 3 IP00 BUILT-IN MODULES LED LINEAR ALLROUND GEN. 3 WU-M-541/xx-C/D, xx-aw, xx-822 These modules were designed for built-in into luminaire casings. They enable a modular luminaire

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Linear LED system with matching light engines and drivers in one

Linear LED system with matching light engines and drivers in one LLS EaseSelect 1150 mm 4500 lm HV2 Datasheet Linear LED system with matching light engines and drivers in one CertaFlux LLS EaseSelect is a linear driver-on-board solution, light engines and corresponding

More information

Generation 3 CXM-22 COB Arrays White LED

Generation 3 CXM-22 COB Arrays White LED CXM-22 Product Datasheet Generation 3 CXM-22 COB Arrays White LED Features: High lumen output and efficacy typical Table of Contents Over 8,280 lm, 148 LPW @ 3000K, 80 CRI, Tj = 85ºC Technology Overview......

More information

SOLOdrive AC, 20W, DALI-2, 1 control channel, constant current, 2x 55V output, side feed, long metal

SOLOdrive AC, 20W, DALI-2, 1 control channel, constant current, 2x 55V output, side feed, long metal 20W DALI 'Dim to Dark' LED Driver SOLOdrive SOLOdrive offers industry-best Natural Dimming to dark - LED dimming made beautiful! With any dimmer, in any application. Symbiosis on SOLOdrive stands for unity,

More information

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , , LINEAR LED DRIVERS PrimeLine DALI DIMMABLE 186445, 186446, 186575, 186576, 186577, 186578 Linear LED drivers with preset operating window or individual programming Typical Applications Built-in in linear

More information

Fortimo LED Line Gen3

Fortimo LED Line Gen3 LED Line 1 ft 1100 lm 1R HV3 Datasheet Fortimo LED Line Gen3 Fortimo LED Line systems are designed to produce pure white light for general lighting applications with high efficiency levels. The Fortimo

More information

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 103349_en_00 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic

More information

LED LIGHTING for Signage

LED LIGHTING for Signage LIGHTING for Signage signanddigital.com/shine-bright LIGHTING up your Signs s XS-1 A slim and compact design, this IP66 rated module gives up to 50,000 working hours and is easy and quick to install with

More information

OT EASY 60 II. LED control unit Operating instructions

OT EASY 60 II. LED control unit Operating instructions II LED control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions

More information

PRODUCT DATA SHEET. ColorBright Color Changing. RGB 150 Series. Year Warranty.

PRODUCT DATA SHEET. ColorBright Color Changing. RGB 150 Series. Year Warranty. PRODUCT DATA SHEET ColorBright Color Changing RGB 150 Series 5 Year Warranty www.flexfireleds.com Weatherproof Color Changing RGB 150 Series Product Datasheet Description The Outdoor ColorBright Color

More information

ROBLITZ Highbay SE Datasheet

ROBLITZ Highbay SE Datasheet Datasheet ROBLITZ Highbay SE series is highly efficient and reliable LED highbay. With very high system efficacy up to 130 lm/w thanks to the state-of-the-art LED technology. It offers flexible options

More information

Tunable White LED linear / area. Module QLE G2 PREMIUM QLE PREMIUM

Tunable White LED linear / area. Module QLE G2 PREMIUM QLE PREMIUM Module QLE G2 PREMIUM QLE PREMIUM Product description Square Tunable White LED module with 2,700 and 6,500 K SMT packages Ideal for linear and panel luminaires Optimal solution for Tunable White applications

More information

CHM-27 COB Arrays White LED

CHM-27 COB Arrays White LED CHM-27 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Part number nomenclature. 4 Ordering part number and flux spec... 5 Operating

More information

3 OSLON 80 SSL Power Linear Board Colours

3 OSLON 80 SSL Power Linear Board Colours 3 OSLON 80 SSL Power Linear Board Colours ILR-ON03-####-SC201-WIR200. Product Overview The Power ON03 from ILS is now the smallest linear strip in the ILS linear portfolio. Each ON03 contains 3 OSLON SSL

More information

CLARA AC CLARA AC 24LED 4W 6W 8W 10W 12W. (2 nd generation)

CLARA AC CLARA AC 24LED 4W 6W 8W 10W 12W. (2 nd generation) CLARA AC CLARA AC 24LED 4W 6W 8W 10W 12W (2 nd generation) A qualified solution to replace and exceed CFL and CDM solutions in Downlights or ambient luminaires. No Driver is required! Page 2 of 26 Designed

More information

Studio. CVM Studio COB Arrays LED Entertainment Lighting. CVM Product Datasheet Preliminary. Features: Table of Contents.

Studio. CVM Studio COB Arrays LED Entertainment Lighting. CVM Product Datasheet Preliminary. Features: Table of Contents. Studio CVM Product Datasheet CVM Studio COB Arrays LED Entertainment Lighting Features: Table of Contents Technology Overview.... 2 Test Specifications... 2 Chromaticity Bins.... 3 Product Ordering & Shipping

More information

OSLON + Square 27 LED PowerFlood Colours

OSLON + Square 27 LED PowerFlood Colours OSLON + Square 27 LED PowerFlood Colours ILF-OO27-xxxx-SC211 Product Overview At the heart of each PowerFlood are 27 OSLON SSL Square ThinGan (UX:3) LEDs. OSLON SSL can be driven up to 1000mA while OSRAM

More information

Generation 3 CIM-9 COB Arrays White LED

Generation 3 CIM-9 COB Arrays White LED Preliminary Generation 3 CIM-9 COB Arrays White LED Features: Table of Contents Technology Overview......2 Test Specifications.........2 Chromaticity Bins..........3 Product Ordering & Shipping Part Number

More information

Generation 3 CXM-9 COB Arrays White LED

Generation 3 CXM-9 COB Arrays White LED Generation 3 CXM-9 COB Arrays White LED Features: Table of Contents Technology Overview......2 Test Specifications.........2 Chromaticity Bins..........3 Product Ordering & Shipping Part Number nomenclature.4

More information

QUINT-PS-3x AC/24DC/10

QUINT-PS-3x AC/24DC/10 3-Phase Primary-Switched Power Supply Unit INTERFACE Data Sheet PHOENIX CONTACT - 12/2005 Description QUINT POWER devices are 60...960 W power supply units for universal use. This is ensured by the wide-range

More information

Generation 3 CLM-14 COB Arrays White LED

Generation 3 CLM-14 COB Arrays White LED Generation 3 CLM-14 COB Arrays White LED Features: Table of Contents Technology Overview......2 Test Specifications.........2 Chromaticity Bins..........3 Product Ordering & Shipping Part Numbers..............4

More information

OSLUX 1 PowerStar IR ILH-IX01-81SL-SC201-WIR200. Product Overview. Applications. Technical Features

OSLUX 1 PowerStar IR ILH-IX01-81SL-SC201-WIR200. Product Overview. Applications. Technical Features OSLUX 1 PowerStar IR ILH-IX01-81SL-SC201-WIR200. Product Overview At the heart of each PowerStar is an OSRAM IR OSLUX Series LED(SFH 4780S). The SFH 4780S offers extremely high radiant intensity for its

More information

CXM-9 COB Arrays White LED

CXM-9 COB Arrays White LED CXM-9 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Part Numbers AA00...5 Part Numbers

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1 Power Supply, Primary Switch Mode, arrow Design -PS-100-240AC/24/1 POWER provides: Extra narrow widths of 22.5, 45, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide range input A high

More information

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) , LINEAR LED DRIVERS ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) 186695, 186696 Typical Applications Built-in in linear luminaires for Industrial lighting ComfortLine with selectable current HIGH POWER

More information

Generation 2 CHM-9-XH20 LED High Density White COB Array

Generation 2 CHM-9-XH20 LED High Density White COB Array Generation 2 CHM-9-XH20 LED High Density White COB Array Features: High lumen output, density Table of Contents Technology Overview......2 Test Specifications.........2 Chromaticity Bins..........3 Product

More information

CC COMPACT DIP SWITCH

CC COMPACT DIP SWITCH CC COMPACT DIP SWITCH COMFORTLINE DIP SWITCH C-R5 186841, 186842, 186843 Typical Applications Built-in in compact luminaires for Shop lighting Downlights Panels ComfortLine DIP switch C-R5 SELECTABLE OUTPUT

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

CHM-11-XH00 LED High Density White COB Array

CHM-11-XH00 LED High Density White COB Array CHM-11 Product Datasheet CHM-11-XH00 LED High Density White COB Array Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part

More information

CXM-9 COB Arrays White LED

CXM-9 COB Arrays White LED CXM-9 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Part Numbers AA00...5 Part Numbers

More information