1 INSTRUCTION MANUAL PSU-RS2 Issue 7A 14 Dec. 05 Proton Instruments Pvt. Ltd. India

2 Table of contents Introduction...4 DeviceNet and Ethernet IP...5 Installation Mechanical...6 Connection...7 Installation - Software...10 USB Driver...10 Installation - Electrical...12 Earth connections & Cable Screens...12 CANBUS Connections between Modules...12 PSU-RS2 configuration Procedure...14 Serial Communications for Diameter Gauge...18 CANBUS...18 RS Parameter Lists...23 Modbus Communications for Diameter Gauge...28 PSU-RS2 RS232 Port...28 ModBus Protocol...28 Serial Communication Data Standard...30 Introduction...30 Proton Standard RS232 Page Access Mode...30 Proton Standard RS232 Parameter Access Protocol...31 PROFIBUS Master to Gauge and RS232 Input List...33 PROFIBUS Gauge to Master and RS232 Output List...34 Specifications

3 Introduction Proton PSU-RS2 is a compact unit which provide adapter function between connection between Proton products and other device. It provides 24VDC power to gauge head via CANBUS; but as default configuration, it will not provide power to DeviceNet network. PSU-RS2 itself can be powered via universal AC power or +24VDC power. The connection to Proton products side is CAN BUS. The connections to user side are as below: USB RS232 RS485 (reserved) DeviceNet (Optional) Industrial IP (Optional) 4

4 DeviceNet and Ethernet IP DeviceNet: eds file is provided in CDROM with the unit. IO package size: 32 bytes. EthernetIP: eds file is provided in CDROM with the unit. IO package size: 32 bytes. Assembly Instance in = 100. Assembly Instance out = 150 Refer to PROFIBUS Master to gauge output list on page 33 for the data that gauge sends to your PLC. Refer to PROFIBUS Gauge to Master input list on page 34 for the data your PLC sends to gauge. DeviceNet and Ethernet IP IO package format (from Byte 0 to Byte 31): Word MSB LSB DW[0] Byte 0 Byte 1 DW[1] Byte 2 Byte 3 DW[2] Byte 4 Byte 5 DW[3] Byte 6 Byte 7 DW[4] Byte 8 Byte 9 DW[5] Byte 10 Byte 11 DW[6] Byte 12 Byte 13 DW[7] Byte 14 Byte 15 DW[8] Byte 16 Byte 17 DW[9] Byte 18 Byte 19 DW[10] Byte 20 Byte 21 DW[11] Byte 22 Byte 23 DW[12] Byte 24 Byte 25 DW[13] Byte 26 Byte 27 DW[14] Byte 28 Byte 29 DW[15] Byte 30 Byte 31 DW[ ]=2 Bytes=16 bits; For DW [ ] detail description please refer to Page 33 and 34. 5

5 Installation Installation Mechanical 6

6 Connection RS485 Connection DIP Switch DIP Setting n 0ff 0ff 0ff Parameter Setting Mode All other state Normal Mode USB Connection Description 7

7 RS232 Connection Ethernet Connection The Ethernet connection on this unit is DTE, not DCE. So when connect to a PC Ethernet card directly, crossover cable should be used; when connect to network via DCE device, straight forward cable should be used. There are the pin number designations for standards 568A/B: T-568B Pin Pair Descrtipion 1 2 TxData TxData RecvData Unused 5 1 Unused 6 3 RecvData Unused 8 4 Unused T-568A Pin Pair Description 1 3 RecvData RecvData TxData Unused 5 1 Unused 6 2 TxData Unused 8 4 Unused Note: Odd pin numbers are always the striped wires. 8

8 DC Power Input Connection CAN bus Connection DeviceNet Connection Pin 4: CANH Pin 1: Earth Pin 3: 0V Pin 5: CANL Pin 2: 24V 9

9 Installation - Software USB Driver System Requirements IBM PC 486DX4-100 MHz CPU or higher or compatible system Available USB port CD-ROM drive Windows 2000,Windows 98,Windows XP Driver Installation (WIN2000) Follow the steps below to install Window 2000 driver of USB-Serial cable: 1. Power on your computer and make sure that the USB port is enabled and working properly. 2. Plug in the USB-Serial cable into the USB port and run the Found New Hardware Wizard to assist you in setting up the new device. Click Next to continue. 3. Insert the USB-Serial cable software driver into the CD-ROM drive and click next to continue. For Windows 98, click Search for a suitable driver for my device (recommend) and click to search driver from the CD-ROM drive \Proton\USB Driver for PSU-RS2. 10

10 4. Windows will detect the driver and Click Next to continue installation. 5. Click Finish to continue and let Windows copy the needed files to your hard disk. 6. You can to check the Device Manager and see the Prolific USB to Serial Comm Port) 11

11 Installation - Electrical Earth connections & Cable Screens Any unit with a mains supply input must have a separate earth wire of at least 6mm 2 attached, this is in addition to the earth wire within the mains lead, do not rely on the mounting bolts to provide an earth path. Use screened cable for all signal connections. Ensure that the cable screens are properly clamped in the glands on the PSU-RS2 units. Ensure that screens of cables connecting to the customer s equipment are clamped to earth at their destination. CANBUS Connections between Modules Cable types A cable with a characteristic impedance of 120 ohms is required when rewireable connectors are used and it is advisable to use DEVICENET standard cable to achieve this, also the cable overall diameter must fit the connector sealing gland. Where the cable length is very short [less than three metres], the cable impedance becomes less important and almost any screened cable can be used. Using pre-wired TURCK connectors [ is generally the best but the most expensive solution. Termination resistors The CANBUS must have termination resistors at each end of the bus, the configuration diagrams show that the gauge are always at the end of the bus therefore these units are supplied with termination resistors connected internally. The PSU-RS2 forms a node on the network when used with the PLED1 therefore the termination resistor is not connected but, if the PLED1 is not used, the termination on the PSU-RS2 is connected by linking the terminal marked 120R to CANH through the dip switch. Isolation The bus driver, 24V supply and the shield pin are isolated from earth at the gauge head but referenced to earth at the PSU-RS2 modules, the cable screen must be connected to the EMC gland on these modules. 12

12 Cable CANBUS/DeviceNet connection to PSU-RS2 The PSU-RS2 has one CANBUS port and one optional DeviceNet port, CANBUS is for connection to gauge head and the other is to DeviceNet. Pre wired female mating connector for gauge to free cable end: Pin designations: Pin 1 Bare = Shield Pin 2 Red = +24V Pin 3 Black = 0V Pin 4 White = CANH Pin 5 Blue = CANL Standard cable lengths = 2, 3, 4, 5, 6, 8, 10, 15, 20, 25, 30, 35, 40, 50 metres. Rewireable female mating connector for gauge Pin designations: Pin 1 = Shield Pin 2 = +24V Pin 3 = 0V Pin 4 = CANH Pin 5 = CANL 13

13 PSU-RS2 configuration Procedure Enter parameter setting mode: Power off PSU-RS2 and connect it to computer via RS232 cable. Set Hyper terminal as (ANSIW, 9600, 8, N, 1, N) Set DIP switch as: 1=ON; 2=OFF; 3=OFF; 4=OFF; Power on the unit, it will go to parameter setting main menu as below. Or In normal mode, enter command config to enter setting mode; Press ESC key to exit current menu and return to upper level menu. Parameter will be stored automatically after modification; new parameters only take effect after restart. Configuration menu Levels: Level 1 (Main Menu) =========================== 1 - PSU-RS2 Function selection 2 - RS232 configuration 3 - ModBus setting 4 - DeviceNet setting 5 - EthernetIP setting 6 - Proton CAN setting Reset to default =========================== Please enter option: Level 1-1 Current Setting: Diameter Gauge 1 Diameter Gauge 2 Length Gauge Please enter option for current Gauge is connected: Level Current Setting: Diameter Gauge 1 - RS232 output mode 2 - Miscellaneous for UART Please enter option: Level Current Setting: Proton HyperTerminal 1 - Proton HyperTerminal 2 - Beta Protocol Please enter option for RS232 output: 14

14 Level Current Setting: EthernetIP 1 - ModBus 2 - DeviceNet 3 - EthernetIP 4 - None Please enter option for UART: Level Current Setting: Length Gauge 1 - UART output mode Please enter option: Level 1-2 Current Setting: N N N N N N N N N N N-1 Please enter option: Level 1-3 Current Setting: Modbus HyperTerminal= N Please enter option: Level 1-4 DeviceNet Setting Current Setting: DeviceNet ID=15 Current Setting: DeviceNet Baudrate=125k 1 - ID 2 - Baudrate 15

15 Please enter option: Level DeviceNet Setting Current Setting: ID =15 Current Setting: Baudrate=125k 1 - ID 2 - Baudrate Please enter option: 1 ID [0...63]: Level DeviceNet Setting Current Setting: Baudrate=125k 1-125k 2-250k 3-500k Please enter option: Level 1-5 EthernetIP Setting Current Setting: IP = Current Setting: SubMask= Current Setting: GateWay= : IP 2: SubMask 3: GateWay Please enter option: Level EthernetIP Setting Current Setting: IP = Current Setting: SubMask= Current Setting: GateWay= : IP 2: SubMask 3: GateWay Please enter option: 1 IP[ ]: Level

16 EthernetIP Setting Current Setting: IP = Current Setting: SubMask= Current Setting: GateWay= : IP 2: SubMask 3: GateWay Please enter option: 2 SubMask[ ]: Level EthernetIP Setting Current Setting: IP = Current Setting: SubMask= Current Setting: GateWay= : IP 2: SubMask 3: GateWay Please enter option: 3 GateWay[ ]: Level 1-6 Proton CAN Setting Current Setting:Baudrate=1000k 1: 250k 2: 500k 3: 750k 4: 1000k Please enter option: Level 1-7 <Default Setting: Connect to Diameter Gauge. RS232 setting=ansiw, N-1, Proton HyperTerminal protocol. UART output mode: None. DeviceNet ID = 15. DeviceNet CAN baud rate = 125k. EthernetIP_ip = EthernetIP_submask= EthernetIP_gateway=

17 Serial Communications for Diameter Gauge CANBUS This is used to communicate between the gauge heads and the other Proton modules. The gauge automatically recognises that it is connected to a module and configures the bus appropriately. It is the only way that the modules and gauge head can be interconnected. The customer cannot use the CANBUS for any other purpose! It is not intended for use with an external CAN network and cannot be used to connect several gauge heads together. Reading FFT Data There are 1024 useful FFT results, these are the amplitudes of the frequency components starting from FFT sample rate / 4096 and ending at FFT sample rate 1024 / 4096, the frequency step is FFT sample rate / The gauge output buffer holds 8 results, the PROFIBUS master must send the Address index of FFT results to the gauge which defines which group of 8 from the 1024 results, is placed into the output buffer. These are updated after the PROFIBUS transmission therefore the new values cannot be read until the next PROFIBUS transmission. The FFT data is read as follows: Set the FFT Run / Hold state to Run. Set the FFT sample rate, this will clear the input buffer and start a new data collection period. A new set of results only becomes available when the Time remaining to update FFT result reaches zero therefore this must be tested before reading the results, the FFT results available bit only means that old results are available. Set Address index of FFT results to 0. On the next transmission increment Address index of FFT results by 8 and read the first 8 results together with the True address index of FFT results [the index will still be the previous value [0] since it is not updated until the transmission is finished. Increment the Address index of FFT results by 8 and read again, repeat this process until all the results are read. If the FFT Run / Hold state is left in the Run state then data will remain stable until a new set of data is collected [this time is 4096s / sampling rate], if the data cannot be read in this time then set the state to Hold until reading is finished. RS232 This is available on the PSU-RS2-AR and PSU-RS2 module and allows for data transmission to standard PCs and any PLC with an RS232 interface. It can work with two protocols as follows: Proton Standard RS232 Page access mode Proton Standard RS232 Parameter Access Protocol 18

18 Beta Standard RS232 Parameter Access Protocol The data format is as follows: No parity No flow control Data bits = 7 Stop bits = 2 Parameter Mode This shows the access codes for individual parameters or blocks of consecutive parameters, these are normally used in a production line environment where the gauge is connected to a PLC or similar device. The parameters are sub-divided into Input and Output parameters which mimic the PROFIBUS Master to Gauge and Gauge to Master pages. Page Mode This is used typically with a Hyper Terminal PC program where each code generates a page of data that is normally used for demonstration purposes. The data can be accessed by typing the Numerical or Alphabetical code followed by the enter key, it is then possible to change presets etc on the page. 19

19 RS232 Input Protocol Request value once for one or a range of Input parameters Note that the parameter value has the appropriate number of digits and includes the sign, as needed but not the decimal point [0.5mm = 500]. Request format 1:? Parameter number Request format 2:? First parameter number Space Number of parameters Reply format 1: Parameter value Reply format 2: First output parameter value Second output parameter value Third output parameter and so on, until the end of the range. RS232 Input Protocol Write a value to single Input parameter. Note that no decimal points are sent. Write format: & Input Parameter number Space Value without decimal point [0.5mm = 500] 20

20 RS232 Output Protocol Request continuously repeating values for one or a range of Output parameters Notes: The repartition rate is approximately 10 per second for a single parameter at a baud rate of at least 1200; if several parameters are sent then the baud rate must be increased otherwise the repartition rate falls. The parameter value has the appropriate number of digits and includes the sign, as needed but not the decimal point [0.5mm = 500]. Request format 1: # Parameter number Request format 2: # First parameter number Space Number of parameters Reply format 1: Parameter value Reply format 2: First output parameter value Second output parameter value Third output parameter and so on, until the end of the range. RS232 Output Protocol Request value once for one or a range of Output parameters Notes: The request and reply format is identical to the # format except that # is replaced by ~. The maximum request rate is 37.5Hz assuming a baud rate of at least 9600 is used. 21

21 RS232 Output Protocol Request a continuously repeating XY average diameter Note that the repartition rate is once per second and includes a decimal point but no spaces. Request format: con1sec Reply format: Two digits Decimal point Three digits RS232 Page Access Codes Numerical Code Alphabetical Code Comments 1 List Command list 2 Mode Diameter measurement mode 3 Stu Measuring status 4 Dia X & Y measured diameter values 5 Cont Continuously updated diameter values 6 Sta Statistics 7 Pre Preset overall & core diameter plus upper & lower limits 8 Fft FFT sampling rate 9 Cor Number of cores in helix mode 10 to 15 Not used 16 Time Gauge running time 17 Cntr Controller presets and operating mode 19 Language Modify the current language rs232 Modify baud rate for RS232 can Modify baud rate for CANBUS 22

22 Parameter Lists PROFIBUS Master to Gauge and RS232 Input Parameter List Note that the Word column defines the PROFIBUS word address or the RS232 parameter number. Word Parameter name Resolution Range 0 Parameter defined as bits, see below 1 Parameter defined as bits, see below 2 Reserved Must be 0 3 Reserved Must be 0 4 Outer diameter preset 1=1um 0~25000 / Core diameter preset 1=1um 0~25000 / Error positive limit 1=1um 0~999 7 Error negative limit 1=1um 0~999 8 Pitch For Helix & Corrugation 10=1mm 2~ Averaging for X & Y diameter 75 = 1sec 1~ Statistics data collection time 10s 10~1000s (Must be set in increments of 10.) 11 Line Speed 1=1m/min 0~3000m/min 12 Address index of FFT results 0, 8, Flaw Detection positive limit 1=1um 0~ Flaw Detection negative limit 1=1um 0~ Reserved Any value 16 Reserved Any value 17 Reserved Any value 18 Parameter defined as bits, see table Controller output range limit 0~50 20 Extruder response delay 0~999s 21 Controller start speed 9999m/min 22 Extruder to Gauge Head distance 0~9999m 23 I & P Gain: I Gain in the high byte 0~ Analogue output 1 full scale value 0~25000 / Analogue output 1 response 0=Fast, >0 =Slow 26 Analogue output 1 type 0 = X, >0 = XY 27 Analogue output 2 full scale value 0~25000 / Analogue output 2 response 0 = fast, >0 = slow 29 Analogue output 2 type 0 = Y, >0 = Error 23

23 PROFIBUS Master to Gauge and RS232 Input Parameter Bit Definition Parameter 0 Bit No. Bit definition Comments 0.0 Solid measurement mode 0.1 Glass measurement mode 0.2 Helix measurement mode 0.3 Corrugation straight measurement mode 0.4 Reserved Must be Reserved Must be Reserved Must be Reserved Any state 0.8 Helix core number = Helix core number = Helix core number = Helix core number = Helix core number = Helix core number = Helix core number > Reserved Any state 1 = select. Select one measurement mode only! 1 = select. Select one core number only! Parameter 1 Bit No. Bit definition Comments 1.0 Statistics Run / Hold state 0 = Run, 1 = Hold 1.1 SPC adaptive preset control 0 = OFF, 1 = ON 1.2 Reserved Any state 1.3 Reserved Any state 1.4 Voltage or pulse speed input for PINT1 or PIND1 0 = Pulse, 1 = Analogue 1.5 Line speed preset on the display 1.6 Line speed measured by PINT1 or PIND1 1.7 Line speed from PROFIBUS 1 = select. Select one source only! 1.8 FFT Run / Hold state 0 = Run, 1 = Hold 1.9 FFT sample rate = 1Hz 1 = select FFT sample rate = 3Hz Select one frequency 1.11 FFT sample rate = 10Hz only! 1.12 FFT sample rate = 30Hz 1.13 FFT sample rate = 100Hz 1.14 FFT sample rate = 300Hz 1.15 FFT sample rate = 600Hz Parameter 18 Bit No. Bit definition Comments 18.0 Controller HOLD 18.1 Controller ON 18.2 Controller RESET 1 = select. Select one state only! 18.3 Controller polarity 0 = Rev, 1 = Normal Reserved Any state 24

24 PROFIBUS Gauge to Master and RS232 Output Parameter List Word Parameter name Resolution Range 0 Parameter defined as bits, see below 1 Parameter defined as bits, see below 2 SSFD Flaw 1 = fault 3 SSFD Last flaw value 1 =1um +/- 0~ Controller Output 1=1% - -50~50 Solid mode diameter XY average value 1=1um 0~25000 / Glass mode diameter XY average value 1=1um 0~25000 / Helix mode envelop 1=1um 0~25000 / Straight corrugation mode maximum 1=1um 0~25000 / Diameter error value 1=1um +/- 0~25000 Solid mode diameter value for X-axis 1=1um 0~25000 / Glass mode diameter value for X-axis 1=1um 0~25000 / Helix mode envelop 1=1um 0~25000 / Straight corrugation mode minimum 1=1um 0~25000 / Solid mode diameter value for Y-axis 1=1um 0~25000 / Glass mode diameter value for Y-axis 1=1um 0~25000 / Helix mode pitch 1=1um 0~65535 Straight Corrugation mode pitch 1=1um 0~ Cable position % X-axis 1 =1% -100~ Cable position % Y-axis 1 =1% -100~ Line speed value in use 1 =1m/min 0~ Standard deviation 1=1um 0~ Maximum diameter 1=1um 0~25000 / Minimum diameter 1=1um 0~25000 / Chi 2 of diameter values in % compared 0~999% to normal distribution. 16 Time remaining to update SPC result 1 = 1s 9990~0 s 17 Time remaining to update FFT result 1 = 1s 4096~0 s 18 Cp 1 = 1% 0~999% 19 Cpk 1 = 1% 0~999% 20 to 23 Reserved for future use 0 will be sent 24 True address index of FFT results 0, 8, Amplitude of FFT result 0 + index 1= 0.1um 0~999.9um 26 Amplitude of FFT result 1 + index 27 Amplitude of FFT result 2 + index 28 Amplitude of FFT result 3 + index 29 Amplitude of FFT result 4 + index 30 Amplitude of FFT result 5 + index 31 Amplitude of FFT result 6 + index 32 Amplitude of FFT result 7 + index 33 Largest amplitude FFT result 1= 0.1um 0~999.9um 34 Frequency of the largest amplitude FFT 1 = ~150Hz 35 result [32 bit word] Hz 36 to 51 Statistical graph data; 16 points covering the range + to -3.2 sigma in 0.4 sigma steps; each data point represents the percentage of data set in that group. 10 = 1% 0 to 99.99% FFT Data for RS232 The FFT amplitude results for the 1024 frequency increments are not available via RS232 because the very large amount of data involved would take too long to send so blocking other data. The following output parameters are deleted: 20 to 32 & 35; parameter 34 alone defines the frequency and sends up to 7 digits. 25

25 PROFIBUS Gauge to Master and RS232 Output Parameter Bit Definition Parameter 0 Bit No. Bit definition Comments 0.0 Solid measurement mode 0.1 Glass measurement mode 0.2 Helix measurement mode 0.3 Straight corrugation measurement mode 1 = mode in use Only one bit will be set at any one time. 0.4 Reserved 0 will be sent 0.5 Diameter distribution not normal 1 = not normal 0.6 Statistic results available 1 = available 0.7 FFT results available 1 = available 0.8 Normal gauge operation 1 = normal 0.9 Diameter above positive error limit 1 = beyond limit 0.10 Diameter below negative error limit 1 = beyond limit 0.11 Controller HOLD 0.12 Controller ON 0.13 Controller RESET 0.14 Controller READY 1 = mode in use Only one bit will be set at any one time Voltage or pulse speed input for PINT1 or PIND1 0 = Pulse, 1 = Analogue Parameter 1 Bit No. Bit definition Comments 1.0 Diameter value not available due to Bits 1.1, 2, 3, 4, 1 = not available 5, 8, 9, 12, Laser or motor fault 1 = fault 1.2 Lens very dirty 1 = dirty 1.3 No cable 1 = no cable 1.4 Internal communication fault 1 = fault 1.5 No reading 1 = no reading 1.6 Wrong parameter sent on CANBUS 1 = wrong 1.7 SPC Effective operating state 1 = ON 1.8 Speed too low in helix or corrugation mode 1 = too low 1.9 Speed too high in helix or corrugation mode 1 = too high 1.10 CANBUS error 1 = error 1.11 PROFIBUS error 1 = error 1.12 DSP error 1 = error 1.13 No meaning 0 will be sent 1.14 No meaning 0 will be sent 1.15 No meaning 0 will be sent 26

26 Beta Lasermike RS232 Single Letter Identifier Protocol Notes No decimal points used Resolution metric = mm, Imperial = inch To request: Send upper case letter Send or or both. Reply to read: Receive upper case letter Receive correct number of digits Receive plus. To write, style 1: Send lower case letter Send the correct number of digits To write, style 2: Send lower case letter Send between one and the correct number of digits Send carriage return or line feed or both Beta Lasermike RS232 Access Codes, Table 5 Req st Write Digits Comments A 5 Actual diameter, single axis only B 5 Position in gate, single axis only C 5 XY Average diameter D 5 X Diameter E 5 Y Diameter F 2 X Position in gate G 2 Y Position in gate H 0 Enable continuous mode I 0 Disable continuous mode J 1 Status: 0 = OK, 1 = Fault K k 1 Control mode: 6 = Reset, 7 = Hold, 8 = Run, 9 = Ready [read only] N n 5 Preset positive error limit O o 5 Preset diameter Q q 3 Number of samples to average [1 to 500] S s 5 Preset negative error limit V 5 Ovality, the absolute value of the difference between X and Y Beta Lasermike RS232 Continuous Data Format Reply, Table 5.1 Data string received Comments $ Start character Gauge head type 7 = PD25, 8 = PD50 Actual diameter Five digits, no decimal point. Status 0 = OK, 1 = No object, 3 = Gate dirty, 5 = No reading Position Sign plus Two digits Cariage return Units M = Metric, I = Imperial Axis X = X axis reading, Y = Y axis reading 27

27 Modbus Communications for Diameter Gauge PSU-RS2 RS232 Port Note that the 0V terminal is referenced to earth and the RTS & CTS not used. The maximum baud rate depends on the cable capacitance and length; for overall screened cable with total screen to core plus core to core capacitance of 300pF per metre, the maximum rate is as follows: Cable length Baud rate 0 to 10m 38K4 10 to 20m 19K2 20 to 40m 9K6 40 to 80m 4K8 Set baud rate through Proton protocol. Set DIP code 0001, enter baudrate to modify baud rate or set baud rate through display on the gauge. And then set DIP code New baud rate will be effective after PSU-RS2 restarted. ModBus Protocol Request values for one or a range of Output parameters Request Command Offset address Data length Error Check! Xx xx Xx Error Check = Command XOR Offset address XOR Data length Reply Command Offset address Data length Data(1) Data(length) Error Check! Xx xx xx xx xx Error Check = Command XOR Offset address XOR Data length XOR Data(1) XOR Data(length) Request values for one or a range of Input parameters Request Command Offset address Data length Error Xx xx xx Error Check = Command XOR Offset address XOR Data length Reply Command Offset address Data length Data(1) Data(length) Error xx xx xx xx xx Error Check = Command XOR Offset address XOR Data length XOR Data(1) XOR Data(length) 28

28 Set values for one or a range of Input parameters Request Command Offset address Data length Data(1) Data(length) Error Check $ Xx xx xx xx xx Error Check = Command XOR Offset address XOR Data length XOR Data(1) XOR Data(length) Reply Command Offset address Data length Error Check $ xx xx xx Error Check = Command XOR Offset address XOR Data length 29

29 Serial Communication Data Standard Introduction CANBUS This is only used to communicate between the gauge head and the other Proton modules; the customer has no control over the data on this bus. PROFIBUS The length gauge head is configured as a PROFIBUS slave. Its operation is totally independent of the CANBUS & RS232 and can operate simultaneously with them. The data that is transferred is described in the PROFIBUS Master to Gauge and RS232 Input Parameter List. This bus is optional and must be fitted during manufacture; it is not possible to add it afterwards. RS232 This is only available on the PSU-RS2-ARQ module and allows for data transmission to standard PCs and any PLC with an RS232 interface. It works independently of the PROFIBUS but the PSU-RS2-ARQ must be connected to the SL1016 to enable the RS232 to function. It can work with two protocols as follows: Proton Standard RS232 Page access mode Proton Standard RS232 Parameter Access Protocol The data format is as follows: No parity No flow control Data bits = 8 Stop bits = 1 Proton Standard RS232 Page Access Mode This is typically used with a Hyper Terminal PC program where each code generates a page of data that is normally used for Demonstration, Test and Calibration purposes. The data can be accessed by typing the Numerical or Alphabetical code followed by the enter key, it is then possible to change presets etc on the page. RS232 Page Access Codes Numerical Alphabetical Comments Code Code 1 list Command list 2 length Continuously updated speed & length value 3 prel1 Preset limit length 1 4 prel2 Preset limit length 2 5 state Display gauge state 6 time Gauge running time canid Set CAN ID 30

30 Proton Standard RS232 Parameter Access Protocol This uses a protocol to access individual parameters or blocks of parameters and is typically used in a production line environment where the gauge is connected to a PLC or similar device. Notes The parameters are split into Input and Output groups, the Input parameters can be both read and written, the Output parameters can only be read The parameter number is the same as the word address used for Profibus data except for the special code con1sec ; refer to the PROFIBUS Master to Gauge and RS232 Input Parameter List for the parameter numbers For Input data: when a word is defined as bits then four hexadecimal characters are required to form the bits 15~0; when a word is defined as a data value then only sufficient characters to define the value in decimal format, with the decimal point where appropriate, are needed; where the data is of double word length then only the first word address is used For Output data: when a word is defined as bits then four hexadecimal characters will be sent; when a word is defined as a data value it is converted to a decimal number with the decimal point but without leading zeros; where a double word is used then only the first word address is used to request the data, the data in both words is automatically converted to a single value If a PC keyboard is being used to enter the codes then the carriage return plus line feed are replaced by the Enter key Set the value of an Input parameter Write Format: & Input Parameter number Space Value without decimal point [0.5m = 50] Request value once for one or a range of Input parameters The request and reply format is identical to the # format given below for output data except that # is replaced by? Request value once for one or a range of Output parameters The request and reply format is identical to the # format given below except that # is replaced by ~. 31

31 Request continuously repeating values for one or a range of Output parameters The repartition rate is the maximum possible and only limited by the data length and baud rate. The parameters must be consecutive when requesting multiple parameters. Request Format 1: # Parameter number Request Format 2: # First parameter number Space Number of parameters Reply Format 1: Parameter value Reply Format 2: First output parameter value Second output parameter value Third output parameter and so on, until the end of the range. Request continuously repeating output of length and speed This uses the code con1sec in place of the parameter number. The repartition rate is once per second with decimal point but no spaces. Request Format: con1sec Reply Format: NNNNN.N (length metres) NNNN.NN (speed m/min) 32

32 PROFIBUS Master to Gauge and RS232 Input List Notes: The Word column defines the PROFIBUS word address or the RS232 parameter number The Profibus page uses words 0~15 [bytes 0~31; the lower byte of each word contains the upper data bits 15~8; where the data is a double word length then the lower word contains the upper bits 31~16] The RS232 protocol uses words 0 ~10, 12, 16, 17 Word Parameter function Units Range 0 Parameter defined as bits, see below 1 Not used 2 Averaging number 1 = 5ms 1~ Hold time 1 = 0.1s 1~100 4 Relay closure time in batch mode 1 = 10ms 1 ~ Preset length 1 1 = 1m {ft} {yds} 0~ Normal mode: Preset length 2 Batch mode: Batch count limit 1 = 1m {ft} {yds} 1 = 1 Count 0~ ~ Pulse per unit length O/P1 1 = 1p/m {p/ft} 0~ Pulse per unit length O/P2 1 = 0.1p/m {p/ft} 0~ Pulse per unit length O/P3 1 = 0.1p/m {p/ft} 0~ Analogue o/p full-scale speed 1 = 1m/min {ft/min} 100~ Minimum speed limit 1 = 0.1m/min {ft/min} 0~ Parameter defined as bits 13 Not Used 14 Length offset 1 = 0.1m {ft} {yds} 0~ Not used Word 0: Bit definitions Bit No. Bit function Comments 0 Measuring mode 0 = Normal, 1 = Batch 1 Reset / accumulate length 1 = Accumulate length 2 Not used 3&4 Measurement units 00 (bit 3 shown first) = Metres 01 = Feet 5 Speed signal source used to generate analogue & pulse outputs 6-15 Not used 10 = Yards (length only, speed in ft/min) 0 = Use average speed value 1 = Use immediate speed value Word 12: Bit definitions Bit No. Bit function Comments 0 Internal or external direction signal source 0 = Internal (bit 12.1) 1 = External (Interface input) 1 Direction for internal source 1 = Down; 0 = Up 2 External direction I/P logic sense For the external signal in a high state then: 1 = Down, 0 = Up 3-15 Not Used 33

33 PROFIBUS Gauge to Master and RS232 Output List Notes: The Word column defines the PROFIBUS word address or the RS232 parameter number The Profibus page uses words 0~15 [bytes 0~31; the lower byte of each word contains the upper data bits 15~8; where the data is a double word length then the lower word contains the upper bits 31~16] The RS232 protocol uses words 1, 2, 4, 9 Word Parameter name Units Range 0 Parameter defined as bits, see below 1 Not Used 2&3 Average Line Speed 1 = 0.01m/min {ft/min} 10~ &5 Immediate Line Speed 1 = 0.01m/min {ft/min} 10~ &7 Length 1 = 0.1m {ft} {yds} 0~ Parameter defined as bits, see below 9 Batch count 1 = 1 10~15 Not used Word 0: Bit definitions Bit No. Bit function Comments 0 Measuring mode 0 = Normal, 1 = Batch 1 Not used 2 Not used 3 Measured length > Preset 1 1 = Length > preset 4 Normal mode: Measured length > P2 Batch mode: Batch count > = limit 1 = Length > preset 1 = Count > = limit 5 Reset / accumulate length 1 = Accumulate length 6&7 Measurement units 00 (bit 3 shown first) = Metres 10 = Feet 8 Speed signal source used to generate analogue & pulse outputs 9 Not used 10 Laser ON 1 = ON 11 Gauge OK 1 = OK 12 No speed measurement available 1 = No signal 13 PROFIBUS communication fault 1 = Fault 14 CANBUS communication fault 1 = Fault 15 RS232 communication fault 1 = Fault Word 8: Bit definitions Bit No. Bit function Comments 0 Internal or external direction signal source 0 = Internal 1 = External 1 Direction for internal source 1 = Down; 0 = Up 2~15 Not used 01 = Yards (length only, speed in ft/min) 0 = Average speed value used 1 = Immediate speed value used 34

34 Specifications CANBUS connection to the gauge head Signals CANH, CANL, Bus 0V, Bus +V output, Shield These are only to be connected to the identical signals on the gauge head. Bus supply output specification Voltage = 24Vdc, referenced to earth. Current = 1.8A RS232 port Signals TX, RX, RTS, CTS, 0V Referenced to earth. Baud rate 1200, 2400, 4800, 9600, & USB Port Signals +5v,D-,D+,GND USB Specification 2.0 compliant; full-speed (12 Mbps) Mains Power Input Voltage = 85 to 264Vac rms Current = 1 A rms maximum Frequency = 47 to 65Hz Power = 35W maximum Environment Ambient temperature range = 0 to +45 C 35

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO DeviceNet/PROFIBUS-DP Adapter - User Manual REV 4.0 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail:gt@sibotech.net Table of Contents 1 ABOUT THIS DOCUMENT...2 1.1 GENERAL... 2

More information

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to

More information

Product Specification for CANbus to DeviceNet Transducer Gateway

Product Specification for CANbus to DeviceNet Transducer Gateway XG CANbus to DeviceNet Transducer Gateway April, 00 Product Specification for CANbus to DeviceNet Transducer Gateway The XG CANbus to DeviceNet Temposonics Gateway gathers position information from as

More information

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T PCIe Card Selection Guide PCIe-CAN Card Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T Channels I/O Isolation Voltage Baud Rate Terminator Resistor I/O PIN Type 2 Max. 1 Mbps Jumper for 120

More information

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to

More information

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide 8 DIGITAL INPUTS INCLUDING 6 X REGISTRATION INPUTS AND 4 BI-DIRECTIONAL I/O 2 ANALOGUE INPUTS AND 2 VOLTAGE OUTPUT AND WDOG RELAY CAN PORT FOR TRIO CAN I/O, DEVICENET SLAVE, CANOPEN OR USER PROGRAMMABLE

More information

Manual and Protocol Description

Manual and Protocol Description Communication Module MSR240 1 Manual and Protocol Description Overview The MSR240 Communication Module serves as an interface between a MSR210 or MSR211 Basic Module and a standard serial data communication

More information

High Performance FieldBus cards

High Performance FieldBus cards Profibus card VLT 5000/6000...2 Interbus card VLT 5000... 4 DeviceNet card VLT 5000... 6 Modbus+ card VLT 5000...8 Lonworks card VLT 5000/6000 Free Topology... 10 Lonworks cards VLT 5000/6000 78 kbps and

More information

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual VirtualSCADA USB to RS422/485 Isolated Converter User Manual Revision 1.01.00 Page 1 (15) Table of contents Warranty and support... 3 Product return... 3 1 About the VirtualSCADA USB to RS422/485 Converter...

More information

MRUC-20 Modul-R CAN Bus Network

MRUC-20 Modul-R CAN Bus Network MRUC-20 Modul-R CAN Bus Network BALOGH This manual is based on information available at the time if its publication. Every effort has been made to provide accurate and up-to-date information. This document

More information

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE

More information

HRM-0800 Instruction Manual

HRM-0800 Instruction Manual HRM-0800 Instruction Manual Table of Contents 1 Highway Addressable Remote Transducer (HART ) 4 2 General Specifications 5 3 Dimensions: 6 4 General Description 7 4.1 Introduction 7 4.2 Purpose 8 4.3 Functions

More information

3.1 I-7560 Pin Assignment and Specifications: Introduction

3.1 I-7560 Pin Assignment and Specifications: Introduction 3.1 I-7560 Pin Assignment and Specifications: Introduction The I-7560 adds a Windows serial Com port via its USB connection and is compatible with new & legacy RS-232 devices. USB Plug and Play allows

More information

USER MANUAL FOR FIOA-0402-U-16

USER MANUAL FOR FIOA-0402-U-16 USER MANUAL FOR FIOA-0402-U-16 COPYRIGHT NOTICE This manual is a publication of Renu Electronics Pvt. Ltd. and is provided for use by its customers only. The contents of the manual are copyrighted by Renu

More information

I/O EXPANSION MODULES

I/O EXPANSION MODULES 4 Trio Motion Technology 4-2 Hardware Reference Manual General Description of I/O Modules Trio Motion Technology s range of digital and analogue input/output expansion modules are designed to enable simple

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway User s Manual www.icpdas.com 1 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one

More information

PROFIBUS Interface WM : PD

PROFIBUS Interface WM : PD ふ PROFIBUS Interface WM : PD4000303 This is a hazard alert mark. This mark informs you about the operation of the product. Note This manual is subject to change without notice at any time to improve the

More information

MOTION COORDINATOR MC405 Quick Connection Guide

MOTION COORDINATOR MC405 Quick Connection Guide CAN PORT FOR TRIOCAN I/O, DEVICENET SLAVE, CANOPEN OR USER PROGRAMMABLE INPUTS INCLUDING REGISTRATION INPUTS BI-DIRECTIONAL I/O ANALOGUE INPUTS AND ANALOGUE OUTPUTS, WDOG RELAY PANEL MOUNT AND DIN RAIL

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

8 PNP or NPN inputs including 8 registration inputs

8 PNP or NPN inputs including 8 registration inputs CAN port for trio CAN i/o, DEVICENET slave, canopen or user programmable 8 PNP or NPN inputs including 8 registration inputs 8 PNP or NPN inputs Backlit Display and status LEDs 8 Digital Outputs RS232

More information

Modbus/ PROFIBUS DP Gateway PM-160

Modbus/ PROFIBUS DP Gateway PM-160 Modbus/ PROFIBUS DP Gateway PM-160 REV 3.2 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail: support@sibotech.net Table of Contents 1 About This Document... 3 1.1 General... 3 1.2

More information

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to

More information

1.5 axis motion controller

1.5 axis motion controller Ver. CHARGE POWER CN3 CN CN SERVOPACK RUN RD MCW5 STS SD 6 +4V SGDH- Ver. CHARGE CN CN3 CN SERVOPACK POWER 0 MCW5 RUN STS RD SD 6 +4V R88A-MCW5-@.5 axis motion controller Advanced motion made perfectly

More information

TABLE OF CONTENTS. Communication Functions

TABLE OF CONTENTS. Communication Functions TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

Interface WM : PD

Interface WM : PD ふ Interface WM : PD4000301 This is a hazard alert mark. This mark informs you about the operation of the product. Note This manual is subject to change without notice at any time to improve the product.

More information

iopro Mirrored IO System

iopro Mirrored IO System Ph: (877) 343-8467 Fax: (800) 303-5381 Email: info@ioselect.com iopro Mirrored IO System Quick Start Guide (Ver. 6) www.ioselect.com Page 1 Introduction This document will cover how to use the iopro family

More information

Characteristics and functioning

Characteristics and functioning Characteristics and functioning 1/27 enod4-c Characteristics and functioning NU-eNod4C-ETH-E-1014_216706-A 1 ENOD4 PRODUCT RANGE... 4 1.1 General presentation... 4 1.2 Versions and options... 4 1.2.1 Versions...

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

Characteristics and functioning

Characteristics and functioning Characteristics and functioning 1/1 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 2/2 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 1 ENOD4 PRODUCT RANGE...

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

VPGate Manual PROFIBUS to serial

VPGate Manual PROFIBUS to serial VPGate Manual PROFIBUS to serial Important information Purpose of the Manual This user manual provides information how to work with the VPGate PROFIBUS to serial. Document Updates You can obtain constantly

More information

DeviceNet Drive Profile CFW-09

DeviceNet Drive Profile CFW-09 Motors Automation Energy Transmission & Distribution Coatings DeviceNet Drive Profile CFW09 Communication Manual DeviceNet Drive Profile Communication Manual Serie: CFW09 Language: English Software Version:

More information

Trajexia motion controller

Trajexia motion controller TJ1- Trajexia motion controller Stand-alone advanced motion controller using MECHATROLINK-II motion bus 16 axes advanced motion controller over a robust and fast motion link MECHATROLINK-II Supports position,

More information

PROFIBUS DP/CAN Gateway PCA-100. User Manual

PROFIBUS DP/CAN Gateway PCA-100. User Manual PCA-100 REV 4.0 SiboTech Automation Co., Ltd. Technical Support: 021-5102 8348 E-mail: support@sibotech.net Catalog 1 Introduction... 2 1.1 About This Instruction... 2 1.2 Copyright... 2 1.3 Related Products...

More information

FEATURES DESCRIPTION FEATURES

FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs 24 Sinking or Sourcing Inputs 16 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate

More information

VLT 5000 DeviceNet and Allen Bradley Control logix 5550

VLT 5000 DeviceNet and Allen Bradley Control logix 5550 Foreword... 2 VLT 5000 DeviceNet card... 2 Configuring the VLT 5000 with RS Networx... 4 I/O communication with RS Logix 5000... 6 Explicit messages with RS Logix 5000... 8 1 Foreword This application

More information

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check Product Description Revision Letter: BA Firmware version: 1.10 Firmware upgrades: DeviceNet Certification: Product Name: None Certificate available upon request. DeviceNet Network Control Module (NCM)

More information

Modular controllers CECX

Modular controllers CECX Key features At a glance Versatile The controller is functionally designed as a master and motion controller. It is a powerful control unit that can Economical simultaneously execute both comprehensive

More information

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual USB to RS-232/RS422/485 US-101-I USB To Serial Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description

More information

Ocean Controls KT-5193 Modbus Programmable Stepper Motor Controller

Ocean Controls KT-5193 Modbus Programmable Stepper Motor Controller Ocean Controls KT-5193 Modbus Programmable Stepper Motor Controller The Ocean Controls Modbus Programmable Stepper Motor Controller is a four axis multifunction programmable stepper motor controller which

More information

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module Installation and Setup 1 2 In This Chapter.... Installing the H0 PSCM The Profibus Network Configuring the Module 2 2 Installing the H0 PSCM Remove the Slot Cover The first step in installing the option

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340 Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340 Previous Configuration: BY240 Synchronous Controller Option: Parallel interface PS240 and BCD thumbwheel switch set BY106-5

More information

Flex+Drive II and MintDrive II Brushless AC Servo. Controls. Product Characteristics Overview

Flex+Drive II and MintDrive II Brushless AC Servo. Controls. Product Characteristics Overview Flex+Drive II and MintDrive II Brushless AC Servo The Flex+Drive II and MintDrive II Series of Brushless AC Servo are a very flexible, versatile range to suit every application whether this is a simple

More information

NF760 Batch Controller

NF760 Batch Controller NF760 Batch Controller Overview The NF760 Batch Controller is suited to flow applications where precise measurement and control of batch quantities is required. Batch total, flow rate, accumulated total

More information

3G3FV SI-P Option Card for Profibus-DP Instructions 02/16/00

3G3FV SI-P Option Card for Profibus-DP Instructions 02/16/00 SI-P Option Card for Profibus-DP Instructions 02/16/00 - Contents - 1 Instruction... 3 1.1 Background... 3 2. Card Installation and set-up... 3 2.1 Option board overview. 3 2.2 Profibus-DP BUS connectors

More information

DN120 DeviceNet Gateway User Manual

DN120 DeviceNet Gateway User Manual DN120 DeviceNet Gateway User Manual DN120 PN 84-210010 Rev A Table of Contents CHAPTER 1 OVERVIEW... 4 CHAPTER 2 INSTALLATION... 5 MOUNTING... 5 WIRING... 6 DeviceNet Interface... 6 Serial Channel Interface...

More information

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation Webinar Organizers Joe Ryan Product Manager Precision Digital Corporation Ryan Shea Applications Specialist Precision Digital Corporation Bruce McDuffee Webinar Moderator Precision Digital Corporation

More information

MEV Limited USB232/485 INSTRUCTION MANUAL

MEV Limited USB232/485 INSTRUCTION MANUAL MEV Limited USB232/485 INSTRUCTION MANUAL USB TO RS232 / RS485 SERIAL COMMUNICATIONS INTERFACE WITH ISOLATION OPTION Issue 5 LIST OF CONTENTS 1 INTRODUCTION 1 1.1 The Products Described in this Manual

More information

High Performance FieldBus cards

High Performance FieldBus cards Profibus card VLT 5000/6000... 2 Interbus card VLT 5000... 4 DeviceNet card VLT 5000... 6 Modbus+ card VLT 5000... 8 Lonworks cards VLT 5000/6000 Free Topology... 10 Lonworks cards VLT 5000/6000 78 kbps

More information

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter Document Name : User Manual for SC10EJ Serial to Ethernet Converter Page 1 of 10 INDEX 1. Technical Specifications 1 2. Modes of Operation 1 3. Configuring the SC10 EJ : Through Serial Port 2 a. Configuring

More information

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2 TRP-C08S USB To 1* RS232 and 1*RS422/485 Isolated Converter User s Manual Printed Jun. 2007 Rev 1.2 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,

More information

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication. 3-3 Wiring NQ-Series models have, besides one power connector, a number of communication ports. Please refer to Table 2.2: Common specifications for NQ-Series and Table 2.3: Specifications per NQ-Series

More information

GRAPHIC DIGITAL INDICATOR

GRAPHIC DIGITAL INDICATOR GRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912-70 Instruction Manual Minebea Co., Ltd. Measuring Components Business Unit EN294-1425 Forwards Thanks you very much for your purchasing MINEBEA

More information

Copyright Extract from Conditions of Sale Safety Warning

Copyright Extract from Conditions of Sale Safety Warning KD420 User Manual Copyright 2004-2013 KK Systems Ltd. No reproduction of any part of this document, in any form, is allowed without prior written permission from KKSystems Ltd. All other copyrights and

More information

1782-JDC DeviceNet/Serial Gateway User s Manual

1782-JDC DeviceNet/Serial Gateway User s Manual 1782-JDC DeviceNet/Serial Gateway User s Manual Western Reserve Controls, Inc. Although every effort has been made to insure the accuracy of this document, all information is subject to change without

More information

Trajexia motion controller

Trajexia motion controller SP IM G AC SERVO DRIVER ADR 0 0 X10 X1 COM 1 3 3 2 9 8 6 7 5 1 4 2 SW1 SW2 CN2 CN1 A/B GRT1-ML2 TJ Trajexia motion controller Motion controllers Stand-alone advanced motion controller over MECHATROLINK-II

More information

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling MATERIAL HANDLING MANIFOLDS WITH DeviceNet INTERFACE 01348(N or G) MH** -- Material Handling 01351(N or G) MH** -- Material Handling Note: N = NPT ports G = BSPP ports SOL 14 SOL 12 Station #3 SOL 14 SOL

More information

USB/PPI+ Programming Cable Driver Procedure. Setting Guideline

USB/PPI+ Programming Cable Driver Procedure. Setting Guideline USB/PPI+ Programming Cable Driver Procedure Setting Guideline Introduction 2 Functions....4 System requirement. 5 The setting of driver procedure. 6 The deletion of driver procedure.10 How to change COM

More information

Product Specification for SAB-S-MODBUS

Product Specification for SAB-S-MODBUS SAB-S-MODBUS May 9, 2011 Product Specification for SAB-S-MODBUS The SAB-S-MODBUS is a two-channel module that measures single or multiple magnet transducer position and returns this information to a host

More information

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Vorne Industries. Model 77/232 Serial Input Numeric 3 Display User's Manual Vorne Industries Model 77/232 Serial Input Numeric 3" Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 Page 2 Model 77/232 Serial Input Numeric 3"

More information

QUICK START GUIDE MC508

QUICK START GUIDE MC508 TECHNOLOGY MICRO SD CARD ETHERNET PORT SERIAL PORT BACKLIT DISPLAY CAN / DEVICENET SLAVE / USER PROGRAMMABLE (5 WAY CONNECTOR) ALALOGUE IN 16 PNP OR NPN INPUTS INC 8 REGISTRATION (I-O CONNECTOR 1) 8 DIGITAL

More information

SI3300. user and installation manual. 4-20mA/DC-Digital Display

SI3300. user and installation manual. 4-20mA/DC-Digital Display SI3300 4-20mA/DC-Digital Display The SI3300 is a member of the SI3000 Readout Family. All members of the family are marked SI3000 on the front panel. This manual is specifically for the SI3300 Model with

More information

Gateway 1400 Reference Manual

Gateway 1400 Reference Manual Profibus-DP Gateway 1400 Reference Manual Copyright All Rights Reserved. No part of this document may be copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

G3 Series DeviceNet TM Technical Manual

G3 Series DeviceNet TM Technical Manual G3 Series DeviceNet TM Technical Manual Table of Contents G3 Series DeviceNet Technical Manual PAGE About DeviceNet... 3 Overview... 3 G3 DeviceNet Features... 3 Cabling and Drop Line Lengths (as defined

More information

Supply Voltage V dc Supply is fully isolated internally, and protected against transients. Internal power modules are CE certified.

Supply Voltage V dc Supply is fully isolated internally, and protected against transients. Internal power modules are CE certified. Features Precision closed loop inertial sensor with optical position feedback and fluid damping Single axis measurement range ±5 to ±45 High resolution measurement

More information

M260 Load Cell Amplifiers

M260 Load Cell Amplifiers E L 4 - + 2-3 1-2 M260 Load Cell Amplifiers Description. This fast start guide shows basic installation, setup, and calibration for most applications. For more specific information contact Minsterport.

More information

Manual Fiber Optic Interfaces

Manual Fiber Optic Interfaces Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it

More information

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0 TRP-C08M USB To 4 RS232/422/485 Isolated Converter User s Manual Printed Jun. 2013 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,

More information

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions. Drawings SD PD-EN Model A Digital Indicating Controller (A-NNN-xx-xx/x) [Style: S] External Dimensions Unit: mm (approx. inch) 96 (.78) (.) 6 (.6) Bracket Terminal cover (.79) 96 (.78) 9.6 (.6) 9.6 (.7).

More information

PCI Express 4-Port Industrial Serial I/O Cards

PCI Express 4-Port Industrial Serial I/O Cards PCI Express 4-Port Industrial Serial I/O Cards The PCIe-400i and PCIe-400i-SI PCI Express 4-port industrial serial I/O cards are plug & play high-speed serial I/O expansion cards for the PCI Express bus.

More information

KTA-250 Anemometer Alarm Card

KTA-250 Anemometer Alarm Card Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments

More information

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation. Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4

More information

Addendum for 125B Bushealth Measurements

Addendum for 125B Bushealth Measurements Addendum for 125B Bushealth Measurements Introduction This Addendum contains information to extend the information presented in the Fluke 125B Users Manual. The purpose of this Addendum is to give more

More information

INTEGRATED MICROSTEPPING MOTOR DRIVER AND HIGH PERFORMANCE MACHINE/PROCESS CONTROLLER

INTEGRATED MICROSTEPPING MOTOR DRIVER AND HIGH PERFORMANCE MACHINE/PROCESS CONTROLLER Sold by Servo Systems Co. 115 Main Road, P.O. Box 97, Montville, NJ 07045-0097 Toll Free: (800) 922-1103 Phone: (973) 335-1007 Fax: (973) 335-1661 www.servosystems.com INTEGRATED MICROSTEPG MOTOR DRIVER

More information

Masibus Automation And Instrumentation Pvt. Ltd.

Masibus Automation And Instrumentation Pvt. Ltd. Operator s Manual DIGITAL CONTROLLER 5006H Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

GRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912B-70. Instruction Manual EN

GRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912B-70. Instruction Manual EN GRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912B-70 Instruction Manual EN294-1796 II Introduction Thanks you very much for your purchasing the Graphic Digital Indicator with PROFIBUS interface

More information

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE 13022001 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS CDN220 PRODUCT OVERVIEW 1 CDN220 INSTALLATION 2 POWER

More information

PCI-SIO8BXS-SYNC. Features:

PCI-SIO8BXS-SYNC. Features: PCI-SIO8BXS-SYNC Eight Channel High Performance Serial I/O PCI Card Featuring /RS232/RS423 Software Configurable Transceivers and 32K Byte Buffers (512K Byte total) The PCI-SI08BXS-SYNC is an eight channel

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps supported Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary

More information

BL compact Multiprotocol Station for Industrial Ethernet 8 Analog Current or Voltage Inputs BLCEN-8M12LT-4AI-VI-4AI-VI

BL compact Multiprotocol Station for Industrial Ethernet 8 Analog Current or Voltage Inputs BLCEN-8M12LT-4AI-VI-4AI-VI On-Machine compact fieldbus I/O blocks EtherNet/IP, Modbus TCP or PROFINET slave Integrated Ethernet switch 10 Mbps/100 Mbps supported Two 4-pin, D-coded M12 connectors for fieldbus connection 2 rotary

More information

MIST Version 2.0 USER S GUIDE. Preliminary Version. INTRODUCTION...2 General Description...2 Models Available...2

MIST Version 2.0 USER S GUIDE. Preliminary Version. INTRODUCTION...2 General Description...2 Models Available...2 1 MIST Version 2.0 USER S GUIDE Preliminary Version INTRODUCTION...2 General Description...2 Models Available...2 INSTALLATION...2 Unpacking...2 Mechanical Installation...3 Electrical Wiring...3 Stand-alone

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

Your complete guide to building an NMEA 2000 network. Issue 1.1

Your complete guide to building an NMEA 2000 network. Issue 1.1 Your complete guide to building an NMEA 2000 network Issue 1.1 Contents Who are the NMEA and What is NMEA 2000? 3 3 Who are the NMEA? 3 What is NMEA 2000? 3 The Network That CAN 3 DeviceNet 3 Certification

More information

Introduction & Specifications of Hi-Speed USB to Serial Adapters

Introduction & Specifications of Hi-Speed USB to Serial Adapters Introduction & Specifications of Hi-Speed USB to Serial Adapters The USB Serial Adapters consist of the following models: USB Single Serial Adapter (ES-U-1001, ES-U-1001-A) USB Single Serial Adapter (ES-U-1001-M,

More information

QUICK START. ATEQ F620 Version 1.0. Reference: MR-28300A-U. (Photo no contractual)

QUICK START. ATEQ F620 Version 1.0. Reference: MR-28300A-U. (Photo no contractual) QUICK START ATEQ F620 Version 1.0 (Photo no contractual) Reference: MR-28300A-U REVISIONS OF THE ATEQ F620 USER MANUAL Due to continuing improvements, the information contained in this user manual, the

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary switches

More information

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation GT200-DP-RS V6.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Gateway...4 1.1 Product Function...4 1.2 Product Features... 4 1.3 Technical Specifications... 4 1.4 Related

More information

Features. IDS : Inclinometer Display System with RS232 Output

Features. IDS : Inclinometer Display System with RS232 Output Graphic Dual Axis Mode Dual Axis Mode Features Single Axis Mode Description Features The IDS is a high quality display system for use with many of our inclinometer sensors. It has a sturdy Aluminium housing

More information

LM058 Bluetooth Serial Adapter

LM058 Bluetooth Serial Adapter LM058 Bluetooth Serial Adapter with external antenna The LM058 Bluetooth Serial Adapter eliminates your conventional RS232 serial cables, providing an easy-to-use, invisible connection with freedom of

More information

Fieldbus Gateway Type ME43

Fieldbus Gateway Type ME43 Fieldbus Gateway Type ME43 Gateway for Industrial Ethernet and Fieldbus standards Up to 128 input and 128 output variables can be assigned Easy integration in the process control system ensured through

More information

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4

More information

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features: Features: Receive all LSI standard radio communications Configurable to be the master of up to 30 sensors, or to listen to unlimited number of devices. Input power supply: 9 to 30V, or USB port, or other

More information

G5 Weighing Instrument

G5 Weighing Instrument G5 Weighing Instrument Program version 1.4.X Fieldbus Option Manual PM and RM types CONTENTS 1. Introduction... 1-1 General... 1-1 Module installation... 1-2 Ordering information... 1-3 2. Modules...

More information

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8O Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the

More information