D&I Breakout Panel Installation and Operation Manual. Part Number MN/D-I.IOM Revision 0

Size: px
Start display at page:

Download "D&I Breakout Panel Installation and Operation Manual. Part Number MN/D-I.IOM Revision 0"

Transcription

1 D&I Breakout Panel Installation and Operation Manual Part Number Revision 0

2

3 D&I Breakout Panel Installation and Operation Manual Comtech EF Data is an ISO 900 Registered Company. Part Number Revision 0 August 9, 005. Copyright Comtech EF Data, 005. All rights reserved. Printed in the USA. Comtech EF Data, 4 West th Street, Tempe, Arizona 858 USA, , FAX: 480..

4 Warranty Policy This Comtech EF Data Corporation product is warranted against defects in material and workmanship for a period of one year from the date of shipment. During the warranty period, Comtech EF Data will, at its option, repair or replace products that prove to be defective. For warranty service, the product must be returned to Comtech EF Data, shipping prepaid by the buyer. Return shipping charges for normal surface delivery within the continental U.S. will be paid by Comtech EF Data. For equipment under warranty, the customer is responsible for freight to Comtech EF Data and all related custom, taxes, tariffs, insurance, etc. Comtech EF Data is responsible for the freight charges only for return of the equipment from the factory to the customer. Comtech EF Data will return the equipment by the same method (i.e., Air, Express, Surface) as the equipment was sent to Comtech EF Data. Limitations of Warranty The foregoing warranty shall not apply to defects resulting from improper installation or maintenance, abuse, unauthorized modification, or operation outside of environmental specifications for the product, or, for damages that occur to improper repackaging of equipment for return to Comtech EF Data. No other warranty is expressed or implied. Comtech EF Data Corporation specifically disclaims the implied warranties of merchantability and fitness for particular purpose. Exclusive Remedies The remedies provided herein are the buyer's sole and exclusive remedies. Comtech EF Data Corporation shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contact, tort, or any other legal theory. Disclaimer Comtech EF Data has reviewed this manual thoroughly in order that it will be an easy-touse guide to your equipment. All statements, technical information, and recommendations in this manual and in any guides or related documents are believed reliable, but the accuracy and completeness thereof are not guaranteed or warranted, and they are not intended to be, nor should they be understood to be, representations or warranties concerning the products described. Further, Comtech EF Data reserves the right to make changes in the specifications of the products described in this manual at any time without notice and without obligation to notify any person of such changes. If you have any questions regarding your equipment or the information in this manual, please contact the Comtech EF Data Customer Service Department. (For more information, refer to the preface.)

5 Preface About this Manual This manual provides installation and operation information for the EFData D&I breakout panel. This is a technical document intended for earth station engineers, technicians, and operators responsible for the operation and maintenance of the D&I breakout panel. Organization This manual includes the following chapters: Chapter provides an introduction. Chapter provides connector and switch information. Revision Numbering Scheme The following table identifies the revision numbering scheme utilized for EFData installation and operation manuals, addenda, and supplements: Part # Revision Level Description MN/D&I Rev. 0 st edition of the manual. MN/D&I Rev. st revision (nd edition) of the manual. MN/D&I_A Rev. Addendum A Addendum A to Rev. of the manual. MN/D&I_B Rev. Addendum B Addendum B to Rev. of the manual. MN/D&I Rev. nd revision (rd edition) of the manual (includes information from Addenda A and B). MN/D&I_SA Supplement A Supplement A to the manual. (The S in SA designates Supplement. ) Note: This is a limited distribution document. i

6 Preface Conventions Used in this Manual Caution and Warning CAUTION CAUTION indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. CAUTION may also be used to indicate other unsafe practices or risks of property damage. WARNING indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury. WARNING Note NOTE This is the style for a note. European EMC Directive In order to meet the European Electro-Magnetic Compatibility (EMC) Directive (EN550, EN5008-), properly shielded cables for DATA I/O are required. More specifically, these cables must be double-shielded from end-to-end, ensuring a continuous ground shield. The following information is applicable for the European Low Voltage Directive (EN0950): <HAR>! Type of power cord required for use in the European Community. CAUTION: Double-pole/Neutral Fusing ACHTUNG: Zweipolige bzw. Neutralleiter-Sicherung International Symbols: Alternating Current. Fuse. Safety Ground. Chassis Ground. NOTE For additional symbols, refer to Caution and Warning listed earlier in this preface. ii

7 Preface Reporting Comments or Suggestions Concerning this Manual Comments and suggestions regarding the content and design of this manual will be appreciated. To submit comments, please contact the EFData Customer Service Department according to the following information. Customer Service Contact the EFData Customer Service Department for: Product support Information on returning a product Information on upgrading a product Product training Reporting comments or suggestions concerning manuals An EFData Customer Service representative may be reached at: EFData Corporation Attention: Customer Service Department 05 West 5th Place Tempe, Arizona 858 USA (0) (0) 9-90 FAX or, can be sent to the Customer Service Department at: service@efdata.com To return an EFData product (in-warranty and out-of-warranty) for repair or replacement:. Request a Return Material Authorization (RMA) number from the EFData Customer Service Department. Be prepared to supply the Customer Service representative with the model number, serial number, and a description of the problem.. To ensure that the product is not damaged during shipping, pack the product in its original shipping carton/packaging.. Ship the product back to EFData. (Shipping charges should be prepaid.) For more information regarding the warranty policies, refer to the disclaimer page located behind the title page. iii

8 Preface This page is intentionally left blank. iv

9 Table of Contents PREFACE... i About this Manual...i Organization...i Revision Numbering Scheme...i Conventions Used in this Manual...ii Caution and Warning...ii Note...ii European EMC Directive...ii Reporting Comments or Suggestions Concerning this Manual...iii Customer Service...iii CHAPTER. INTRODUCTION... CHAPTER. CONNECTORS AND SWITCHES.... Drop Data Input, Insert Data Output, and Ext. Ref CLK.... Drop Data Output (J).... Insert Data Input (J)....4 Insert Data Output (J4)....5 Drop Data Input (J5) Drop Data Output (J)... 8 v

10 Preface. Insert Data Input (J) Insert Data Output (J8) External Reference Clock (J9) ESC Channel (J0) Faults (J) Data Interface (J)... 0 Figures Figure -. D&I Breakout Panel... Figure -. D&I Daughter Card Schematic... Figure -. D&I Breakout Panel Schematic... 4 Figure -. D&I Breakout Panel Schematic (Cont d)... 5 Tables Table -. D&I Breakout Panel Connectors... Table -. D&I Breakout Panel Switch Selections... vi

11 Chapter. INTRODUCTION The D&I (B-08-5) breakout panel provides standardized interfaces for the D&I capabilities of the modem. The balanced and unbalanced interfaces for drop DATA I/O and insert DATA I/O are provided and are selectable with rear panel DIP switches. This breakout panel is used in : or M:N switching configurations. The D&I breakout panel supports the use of the D&I channel unit in the modem. Refer to Chapter for connector and switch information.

12 Introduction This page is intentionally left blank.

13 Chapter. CONNECTORS AND SWITCHES The locations of the connectors and D&I switches S through S5 are shown in Figure -. Refer to Table - for D&I breakout panel connector information. Refer to Table - for the D&I breakout panel switch selections. The D&I PCB schematic is shown in Figure -. Refer to Figure - for the D&I breakout panel schematic.

14 Connectors ans Switches FRONT VIEW J J DROP INPUT DROP OUTPUT INSERT INPUT J INSERT OUTPUT J4 DROP IN INSERT IN OUT J5 J J OUT J8 EXT REF CLK J9 J0 ESC CHANNEL C G C O N N N ON N MC O D MC O J FAULTS PRI SEC REAR VIEW S OPEN J LOOP 4 NORM S4 S CLOSED OPEN OPEN CLOSED S CLOSED DCE DTE S5 Figure -. D&I Breakout Panel Table -. D&I Breakout Panel Connectors Ref Desig. Connector Type Name J 5-pin D Drop Data Input J 5-pin D Drop Data Output J 5-pin D Insert Data Input J4 5-pin D Insert Data Output J5 BNC Drop Data Input J BNC Drop Data Output J BNC Insert Data Input J8 BNC Insert Data Output J9 BNC Ext. Ref Clock J0 5-pin D ESC Channel J Terminal Block Faults J 50-pin D Data Interface

15 Connectors ans Switches Table -. D&I Breakout Panel Switch Selections Signal Function Name Switch Switch # Position Unbalanced Drop Data Input DDI S, /, 4 ON/OFF Balanced Drop Data Input DDI S, /, 4 OFF/ON Unbalanced Drop Data Output DDO S 5, /, 8 OFF/ON Balanced Drop Data Output DDO S 5, /, 8 ON/OFF Unbalanced Insert Data Input IDI S, /, 4 OFF/ON Balanced Insert Data Input IDI S, /, 4 ON/OFF Unbalanced Insert Data Output IDO S 5, /, 8 OFF/ON Balanced Insert Data Output IDO S 5, /, 8 ON/OFF Unbalanced Ext. Reference Clock EXC S, /, 4 OFF/ON Balanced Ext. Reference Clock EXC S, /, 4 ON/OFF Drop Output/Insert Input Loopback DDO/IDI S4 N/A UP Normal S4 N/A DOWN Drop Data Output DCE/DTE Select DDO S5 N/A UP DCE/DTE S5 N/A DOWN NOTE S through S5 are ON in the down position (toward PCB). J DB5 INSERT INPUT DATA JP J HEADER 8X DB5 DROP DATA INPUT/ INSERT DATA OUTPUT/ EXT REF CLK Figure -. D&I Daughter Card Schematic

16 Connectors ans Switches J5 DROP INPUT DATA T Cont. next page R : XF8 A J DROP DATA OUTPUT T J R : XF8 S5 SW DPDT DROP DATA OUTPUT DCE/DTE SELECT S SW DIP-8 S SW DIP DDI-A DDI-B DDO-A DDO-B EXC-A EXC-B DB5 DROP OUTPUT DATA S4 IDI-A IDI-B J9 EXT REF CLOCK T5 DDO-A R DDO-B : XF8 JP SW DPDT DROP OUTPUT/ INSERT INPUT LOOP HEADER 8X J INSERT INPUT DATA T R : XF8 J8 INSERT OUTPUT DATA T4 R : XF8 J IDO-A IDO-B S SW DIP IDI-A IDI-B IDO-A IDO-B DB5 INSERT OUTPUT DATA Figure -. D&I Breakout Panel Schematic 4

17 Connectors ans Switches 5 PRI_COM A PRI_NO PRI_NC J 8POSTERMBLK TERTXDAT TERRXDAT J0 DB5 ESC DDI-A DDI-B EXC-A P0 P4 4 P8 8 P0 P5 5 P9 9 P0 P P0 0 P04 4 P P P05 5 P8 8 P P0 P9 9 P P0 P40 40 P4 4 P08 8 P4 4 P5 5 P09 9 P4 4 P P0 0 P4 4 P P P44 44 P8 8 P P45 45 P9 9 P P4 4 P0 0 P4 4 P4 4 P P5 5 P48 48 P P P49 49 P P P50 50 J DB50 DDO-A DDO-B IDI-A IDI-B IDO-A IDO-B EXC-B TERTXDAT TERRXDAT DSR RTS/CTS SEC_COM SEC_NO SEC_NC PRI_COM PRI_NC PRI_NO SEC_COM SEC_NO SEC_NC DSR Cont. from previous page Figure -. D&I Breakout Panel Schematic (Cont d)

18 Connectors ans Switches. Drop Data Input, Insert Data Output, and Ext. Ref CLK This signal connection is a 5-pin female D connector (J) located at the front of the breakout panel. Screw locks are provided for mechanical security of the mating connector. Signal Function Name Pin # Ground GND, 4 Insert Data Out IDO A IDO B External Clock EXC A EXC B 8 Drop Data Input DDI A DDI B 9 For J selections, use S, S, and S, located at the rear of the breakout panel. Signal Function Name Switch Switch # Position Balanced Insert Data Output IDO S 5, /, 8 ON/OFF Balanced Drop Data Input DDI S, /, 4 ON/OFF Balanced External Clock EXC S, /, 4 ON/OFF. Drop Data Output (J) The balanced drop data output connection is a 5-pin female D connector located at the front of the breakout panel. Screw locks are provided for mechanical security of the mating connector. Signal Function Name Pin # Ground GND, 4 Drop Data Output DDO A DDO B 9 Drop Data Output DDO A DDO B For J selections, use S and S5 located at the rear of the panel. Signal Function Name Switch Switch # Position Balanced Drop Data Output DDO S5 N/A UP (DCE/DTE Select) Unbalanced Drop Data Output DDO S 5, /, 8 OFF/ON Balanced Drop Data Output DDO S 5, /, 8 ON/OFF NOTE S is ON in the down position (toward PCB).

19 Connectors ans Switches. Insert Data Input (J) The balanced insert data input connection is a 5-pin female D connector located at the front of the breakout panel. Screw locks are provided for mechanical security of the mating connector. Signal Function Name Pin # Ground GND, 4 Insert Data Input IDI A IDI B For J selections, use S located at the rear of the panel. Signal Function Name Switch Switch # Position Unbalanced Insert Data Input IDI S, /, 4 OFF/ON Balanced Insert Data Input IDI S, /, 4 ON/OFF NOTE S is ON in the down position (toward PCB)..4 Insert Data Output (J4) The balanced insert data output connection is a 5-pin female D connector located at the front of the breakout panel. Screw locks are provided for mechanical security of the mating connector. Signal Function Name Pin # Ground GND, 4 Insert Data Output IDO A IDO B For J4 selections, use S located at the rear of the panel. Signal Function Name Switch Switch # Position Unbalanced Insert Data Output IDO S 5, /, 8 OFF/ON Balanced Insert Data Output IDO S 5, /, 8 ON/OFF NOTE S is ON in the down position (toward PCB).

20 Connectors ans Switches.5 Drop Data Input (J5) The unbalanced and balanced drop data input connection is a BNC connector located at the front of the breakout panel. For J5 selections, use S located at the rear of the panel. Signal Function Name Switch Switch # Position Unbalanced Drop Data Input DDI S, /, 4 ON/OFF Balanced Drop Data Input DDI S, /, 4 OFF/ON NOTE S is ON in the down position (toward PCB).. Drop Data Output (J) The unbalanced and balanced drop data output connection is a BNC connector located at the front of the breakout panel. For J selections, use S located at the rear of the panel. Signal Function Name Switch Switch # Position Unbalanced Drop Data Output DDO S 5, /, 8 OFF/ON Balanced Drop Data Output DDO S 5, /, 8 ON/OFF NOTE S is ON in the down position (toward PCB).. Insert Data Input (J) The unbalanced and balanced insert data input connection is a BNC connector located at the front of the breakout panel. For J selections, use S located at the rear of the panel. Signal Function Name Switch Switch # Position Unbalanced Insert Data Input IDI S, /, 4 OFF/ON Balanced Insert Data Input IDI S, /, 4 ON/OFF NOTE S is ON in the down position (toward PCB). 8

21 Connectors ans Switches.8 Insert Data Output (J8) The unbalanced and balanced insert data output connection is a BNC connector located at the front of the breakout panel. For J8 selections, use S located at the rear of the panel. Signal Function Name Switch Switch # Position Unbalanced Insert Data Output IDO S 5, /, 8 OFF/ON Balanced Insert Data Output IDO S 5, /, 8 ON/OFF NOTE S is ON in the down position (toward PCB)..9 External Reference Clock (J9) The unbalanced and balanced external reference clock input is a BNC connector located at the front of the breakout panel. For J9 selections, use S, located at the rear of the panel. Signal Function Name Switch Switch # Position Unbalanced External EXC S, /, 4 OFF/ON Reference Clock Balanced External Reference Clock EXC S, /, 4 ON/OFF NOTE S is ON in the down position (toward PCB)..0 ESC Channel (J0) The ESC Channel interface is a 5-pin female D connector located at the front of the breakout panel. Screw locks are provided for mechanical security of the mating connector. Signal Function Name Pin # Ground GND, Terrestrial Tx Data Terrestrial Rx Data TER TXDAT TER RXDAT Request To Send RTS 4 Clear To Send CTS 5 Data Set Ready DSR NOTE RTS and CTS are looped together on the connector. 9

22 Connectors ans Switches. Faults (J) The Faults connection is an 8-position terminal block located at the front of the breakout panel. Signal Function Name Pin # Ground GND, 5 Primary Common Primary Norm/Open Primary Norm/Closed PRI COM PRI NO PRI NC 4 Secondary Common Secondary Normally Open Secondary Normally Closed SEC COM SEC NO SEC NC 8. Data Interface (J) The data interface connection is a 50-pin female D connector located at the rear of the breakout panel. Screw locks are provided for mechanical security of the mating connector. Signal Function Name Pin # Ground GND, Drop Data Input DDI A DDI B 4 8 External Clock EXC A EXC B 5 9 Insert Data Output IDO A IDO B 0 Drop Data Output DDO A DDO B 8 Terrestrial Tx Data Terrestrial Rx Data TER TXDAT TER RXDAT 5 Insert Data Input IDI A IDI B 9 40 Primary Common Primary Normally Open Primary Normally Closed PRI COM PRI NO PRI NC 0 4 Secondary Common Secondary Normally Open Secondary Normally Closed SEC COM SEC NO SEC NC 44 8 Data Set Ready DSR 48 Terrestrial ESC DSR TER ESC DSR 4 0

23 METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter centimeter x inch x foot x yard x meter x 0-4 mile.09 x 0 5. x x 0.0 x 0.09 x 0.09 mm 0.09 kilometer 0. Temperature Conversions Unit Fahrenheit Centigrade Formulas Fahrenheit 0 (water freezes) C = (F - ) * Fahrenheit 00 (water boils) F = (C *.8) Fahrenheit. (absolute 0) Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoir. Pound Troy Kilogram gram oz. avoir oz. troy lb. avoir lb. Troy kilogram.0 x

24 4 WEST TH STREET TEMPE ARIZONA 858 USA PHONE 480 FAX

CiM-25. Quick Start Guide. IP-Enabled M&C Part Number CD/CIM25QSG.IOM Rev. 0

CiM-25. Quick Start Guide. IP-Enabled M&C Part Number CD/CIM25QSG.IOM Rev. 0 CiM-25 Quick Start Guide IP-Enabled M&C Part Number Rev. 0 CiM-25 Quick Start Guide Comtech EF Data is an ISO 9001 Registered Company. IP Enabled M&C Part Number REV. 0 March 3, 2004 Copyright Comtech

More information

CiM. Quick-Start Guide

CiM. Quick-Start Guide CiM Quick-Start Guide For IP-Enabled Satellite Modems Part Number: Rev. 1 Sept. 9, 2002 CiM Quick-Start Guide Comtech EF Data is an ISO 9001 Registered Company. For IP Enabled Satellite Modems Part Number

More information

CIC-35 LVDS to ASI. Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EF Data CDM-600 Modems)

CIC-35 LVDS to ASI. Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EF Data CDM-600 Modems) CIC-35 LVDS to ASI Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EF Data CDM-600 Modems) Part Number Revision 0 August 22, 2003 Copyright Comtech EF

More information

UB-530. Breakout Panel Installation and Operation Manual. Part Number MN/UB530.IOM Revision 2

UB-530. Breakout Panel Installation and Operation Manual. Part Number MN/UB530.IOM Revision 2 UB-530 Breakout Panel Installation and Operation Manual Part Number Revision 2 UB-530 Breakout Panel Installation and Operation Manual Comtech EF Data is an ISO 9001 Registered Company. Part No. Revision

More information

M&C Software. for Windows. Windows-Based Monitor and Control Software for Comtech EF Data Satellite Terminals User s Guide

M&C Software. for Windows. Windows-Based Monitor and Control Software for Comtech EF Data Satellite Terminals User s Guide M&C Software for Windows Windows-Based Monitor and Control Software for Comtech EF Data Satellite Terminals User s Guide Part Number IO Revision 4 IMPORTANT NOTE: The information contained in this document

More information

CMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1

CMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1 CMR-8500 Quick Start Guide CMR-8500 DVB IP Encapsulator Part Number MN-CMR68500-QSG REV. 1 Copyright Comtech EF Data, 2008. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street,

More information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR

More information

CRS-150. Part Number MN/CRS150.IOM Revision 2

CRS-150. Part Number MN/CRS150.IOM Revision 2 CRS-150 1:1 Redundancy Switch Installation and Operation Manual Accessory Product for use only with Comtech EF Data CDM-600 Modems (Requires Modem Firmware Version 1.1.0 or Higher) IMPORTANT NOTE: The

More information

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators USER MANUAL MODELS 1205 and 1205/34 Synchronous V.35 Modem Eliminators An ISO-9001 Certified Company Part #07M1205-D Doc #049021U, Rev. E Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 2012 SAFETY NOTICE Universal Interface Device 47 (UID46) connects

More information

Automated Tuner System Power Distribution Hub

Automated Tuner System Power Distribution Hub User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 202 SAFETY NOTICE Universal Interface Device 47 (UID47) connects two

More information

87421/22A Power Supply. Operating and Service Manual

87421/22A Power Supply. Operating and Service Manual 87421/22A Power Supply Operating and Service Manual Agilent Part Number: 87421-90001 Printed in USA April 2001 Supersedes: September 1998 Notice The information contained in this document is subject to

More information

MEC-COM-M154. User s Manual

MEC-COM-M154. User s Manual MEC-COM-M154 Mini PCI-e 2-port RS-232 and 2-port RS232/422/485 serial board with power input User s Manual Third Edition, February 2014 2014 Cervoz Co., Ltd. All rights reserved. Reproduction without permission

More information

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter USER MANUAL MODEL 011 High Speed Asynchronous to Synchronous Converter Part# 07M011-A Doc# 0601UA Revised 03/16/94 SALES ICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY

More information

Ethernet to J1939 Installation Guide AB7665. Part no. SP0863 Rev. 1.01

Ethernet to J1939 Installation Guide AB7665. Part no. SP0863 Rev. 1.01 Anybus X-gateway Ethernet to J1939 Installation Guide AB7665 Part no. SP0863 Rev. 1.01 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China + 49-721 - 96472-0 + 81-45 - 478-5340 +

More information

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 552 Series High Speed Telco Surge Protectors C E R T I F I E D An ISO-9001 Certified Company Part# 07M552-E Rev. G Revised 01/27/10 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)

More information

Release 1.1 NetVue Provisioning Guide

Release 1.1 NetVue Provisioning Guide Comtech EF Data is an AS9100 Rev B / ISO9001:2000 Registered Company Release 1.1 NetVue Provisioning Guide IMPORTANT NOTE: The information contained in this document supersedes all previously published

More information

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B User Guide DMXSM-H18 Splitter DMXSM-H81 Merger Document Release Aug. 2008 Revision B Warranty Leviton Manufacturing Co Inc. warrants this device to be free of material and workmanship defects for a period

More information

PV3500. Fuel Site Controller. Service Manual OPW Fuel Management Systems Manual M Rev. 1

PV3500. Fuel Site Controller. Service Manual OPW Fuel Management Systems Manual M Rev. 1 PV3500 Fuel Site Controller Service Manual 2002 OPW Fuel Management Systems Manual M11-00.03 Rev. 1 OPW Fuel Management Systems - System and Replacement Parts Warranty Statement Effective September 1,

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

MEC-COM-M114. User s Manual

MEC-COM-M114. User s Manual MEC-COM-M114 Mini PCI-e 4-port RS-232 serial board with power input User s Manual Third Edition, February 2014 2014 Cervoz Co., Ltd. All rights reserved. Reproduction without permission is prohibited Mini

More information

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

Integrated Stepper Drive & Motor

Integrated Stepper Drive & Motor SMD23 Integrated Stepper Drive & Motor Manual #: 940-0S050 User Manual AMCI Motion Control Products Important User Information The products and application data described in this manual are useful in a

More information

An ISO-9001 Certified Company

An ISO-9001 Certified Company USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS PRODUCT FEATURES MODELS: IIA SPRINT 310/510/710 200/250 2000 SERIES 3000 SERIES

More information

CRS :10 Redundancy Switch Installation and Operation Manual Part Number MN/CRS300.IOM Revision 4

CRS :10 Redundancy Switch Installation and Operation Manual Part Number MN/CRS300.IOM Revision 4 CRS-300 1:10 Redundancy Switch Installation and Operation Manual Part Number Revision 4 CRS-300 Comtech EF Data is an ISO 9001 Registered Company. 1:10 Redundancy Switch Installation and Operation Manual

More information

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Agilent Technologies E5339A 38-Pin Low-Voltage Probe Agilent Technologies E5339A 38-Pin Low-Voltage Probe Installation Note The 38-pin low-voltage probe provides a convenient way to connect two Agilent Technologies logic analyzer probe cables to a small

More information

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY MUX-2 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

User Guide. Control Box. RoscoLED TM.

User Guide. Control Box. RoscoLED TM. RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260

More information

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual Contents HP E1586A Rack Mount Terminal Panel User s Manual Description... 5 Connecting to VXIbus Instruments... 5 Interconnect Cables... 5 Terminal Block Connections... 6 Using the Terminal Panel for Reference

More information

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF Instruction Manual Model 2082-1972 Power Supply July 2012, Rev. B MODEL 2082 POWER SUPPLY CROSS TECHNOLOGIES INC. PRIMARY PWR AC BUC +48V AUX BUC TX SELECT 48V +18V/48V LNB RX +18V ANT CNTR +29V AC 18V

More information

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY MUX-485 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

BCD Interface for the 520 Indicator DISCONTINUED. Installation and Configuration Manual Rev A

BCD Interface for the 520 Indicator DISCONTINUED. Installation and Configuration Manual Rev A BCD Interface for the 520 Indicator Installation and Configuration Manual 76127 Rev A Contents About This Manual... 1 1.0 Introduction... 1 2.0 Installation... 2 2.1 BCD Option Card Installation.....................................................

More information

TH2683 Insulation Resistance Meter. User s Mannual

TH2683 Insulation Resistance Meter. User s Mannual TH2683 Insulation Resistance Meter User s Mannual 1 CONTENTS Chapter 1 Genernal Information... 3 1.1 Feature Overview... 3 1.2 Operating Environment... 3 1.3 Dimensions and Weight... 3 1.4 Unpacking Inspection...

More information

BCD Interface for the 520 Indicator. Installation and Configuration Manual

BCD Interface for the 520 Indicator. Installation and Configuration Manual BCD Interface for the 520 Indicator Installation and Configuration Manual 7627 Contents About This Manual....0 Introduction... 2.0 Installation... 2 2. BCD Option Card Installation.......................................................

More information

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch 12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:

More information

SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL

SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL REVISION: 7/02 COPYRIGHT (c) 1998-2002 CAMPBELL SCIENTIFIC, INC. This is a blank page. Warranty and Assistance The SC532A 9-PIN PERIPHERAL

More information

MiniModules. Reference Manual. Series R CT 3002 V 1.0 MiniModule USB Service Adapter and Software

MiniModules. Reference Manual. Series R CT 3002 V 1.0 MiniModule USB Service Adapter and Software Reference Manual R CT 3002 V 1.0 MiniModule USB Service Adapter and Software Series 3000 MiniModules LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany www.lynx-technik.com Information in this document

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

Universal Patch Platform Uni-Patch System Patch and Test Module User Manual

Universal Patch Platform Uni-Patch System Patch and Test Module User Manual Universal Patch Platform Uni-Patch System Patch and Test Module User Manual 2-42937-9758 Universal Patch Platform Uni-Patch System Patch and Test Module User Manual 2-42937-9758 1991, 1992, 1993, 1994,

More information

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001 INSTRUCTION MANUAL Sensoray Model 720RB/DIN Relay I/O Board (Rev A) October 12, 2001 For Technical Support contact Sensoray Co., Inc. 7313 SW Tech Center Dr., Tigard, Oregon 97223, USA Tel:(503) 684-8005

More information

Instruction Manual. CT-4 High-Current Transformer

Instruction Manual. CT-4 High-Current Transformer Instruction Manual CT-4 High-Current Transformer 070-6478-02 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information

More information

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 2014 Interface Powered RS-530 to V.35 Converter An ISO-9001 Certified Company Part #07M2014-C Doc. #070011UC Revised 4/22/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007

More information

P O W E R S U P P L Y M A N U A L

P O W E R S U P P L Y M A N U A L POWER SUPPLY MANUAL Congratulations on the purchase of your new Corsair power supply. This User Agreement (the Agreement ) is a legal agreement between you ( You ), and Corsair Memory, Inc. ( Corsair ).

More information

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL REVISION: 1/93 COPYRIGHT (c) 1987, 1993 CAMPBELL SCIENTIFIC, INC. WARRANTY AND ASSISTANCE The SC32A OPTICALLY ISOLATED RS232 INTERFACE is warranted

More information

Power Rack 58. EXT-PS5-8R User Manual.

Power Rack 58. EXT-PS5-8R User Manual. Power Rack 58 EXT-PS5-8R User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday

More information

PCM-7140 Pulsed Current Source Operation Manual

PCM-7140 Pulsed Current Source Operation Manual PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031

More information

Model VT120 Fast Timing Preamplifier Operating and Service Manual

Model VT120 Fast Timing Preamplifier Operating and Service Manual Model VT120 Fast Timing Preamplifier Operating and Service Manual Printed in U.S.A. ORTEC Part No. 740360 1202 Manual Revision C Advanced Measurement Technology, Inc. a/k/a/ ORTEC, a subsidiary of AMETEK,

More information

User Manual TLS HDMI Switch Splitter 3/2

User Manual TLS HDMI Switch Splitter 3/2 875224 User Manual TLS HDMI Switch Splitter 3/2 IR SW B A 3 2 1 HDMI IN HDMI OUT DC 5V 1 2 3 A B 8 875224 HDMI Switch Splitter 3/2 Thank you for purchasing this product. For optimum performance and safety,

More information

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2. Page 1 of 5 Model 282 Total Interface Isolation Module Reference Manual 0315-0169 Rev. A Print 08.01.01 1.0 General Description Table of Contents 2.0 Specifications 2.1 Interface 2.2 Connectors 2.3 Isolation

More information

SMD Series Integrated Stepper Driver and Motor Revision 1.3

SMD Series Integrated Stepper Driver and Motor Revision 1.3 The AMCI Integrated Stepper Motor and Microstepping Drive Combination represents the future of Stepper Motor Control applications. The SMD is a self-contained stepper motor and driver package, capable

More information

USER MANUAL MODEL 515 DB-15 Surge Protector

USER MANUAL MODEL 515 DB-15 Surge Protector USER MANUAL MODEL 515 DB-15 Surge Protector Part# 07M515-A Doc# 074220U, Rev. B Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY Patton Electronics

More information

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter USER MANUAL MODEL 2030 Bidirectional (IEEE-1284) Line Driver/Converter An ISO-9001 Certified Company Part # 07M2030-B Doc. #102121U, Rev. C Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

RS422 PORT SWITCHER REMOTE CONTROL PANEL

RS422 PORT SWITCHER REMOTE CONTROL PANEL 12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com Model No. SW32PS-RCP RS422 PORT SWITCHER REMOTE CONTROL PANEL User Manual Rev 1.01 TABLE OF

More information

Quick Start/Installation Guide

Quick Start/Installation Guide Agilent Technologies E5850A Time Correlation Fixture Quick Start/Installation Guide The Agilent E5850A time correlation fixture allows you to make time-correlated measurements between a 1680/90 or 16700

More information

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule User s Manual ISO9001 and AS9100 Certified BDM-610020066 Rev. E CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s Twisted

More information

OP8662 High Voltage and Current Probe User Guide.

OP8662 High Voltage and Current Probe User Guide. OP8662 High Voltage and Current Probe User Guide www.opal-rt.com Published by OPAL-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec, Canada H3K 1G6 www.opal-rt.com 2011 OPAL-RT Technologies,

More information

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1052 idsl Modem with RS-232 Interface An ISO-9001 Certified Company Part# 07M1052-B Doc# 058061UB Revised 5/24/02 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 TABLE OF

More information

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detection Relay And Probe Revision 8.1 Change Log: Rev 8.1 Apr 24 2012 JNesbitt@GPS-US.co GPS updates

More information

Model SPDT 5A Relays

Model SPDT 5A Relays Model 4048 48 SPDT 5A Relays 90900220 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics,

More information

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual 12843 Foothill Blvd., Suite D Sylmar, CA 91342 818 898 3380 voice 818 898 3360 fax www.dnfcontrolscom The Analyst RS422/RS232 Tester (Standard Model) User Manual Manual Revision 102506 Table of Contents

More information

Model SPDT Switch Module

Model SPDT Switch Module Model 4148 48 SPDT Switch Module 90900210 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics,

More information

Analog Interface Unit Operation Manual

Analog Interface Unit Operation Manual Analog Interface Analog Interface Unit Operation Manual WARRANTY Accurate Technology, Inc. warrants the product against defective parts and workmanship for 1 year commencing from the date of original purchase.

More information

HD-1X4-4K User Manual

HD-1X4-4K User Manual HD-1X4-4K User Manual Factor Electronics. Contact: info@factorelectronics.com 1 Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully before

More information

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual Series 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication, no guarantee

More information

DisplayPort Booster. EXT-DP-141B User Manual.

DisplayPort Booster. EXT-DP-141B User Manual. DisplayPort Booster EXT-DP-141B User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM

More information

Model 4001A Modular System Bin Operating and Service Manual

Model 4001A Modular System Bin Operating and Service Manual Model 4001A Modular System Bin Operating and Service Manual Printed in U.S.A. ORTEC Part No. 733740 0704 Manual Revision D $GYDQFHG0HDVXUHPHQW7HFKQRORJ\,QF a/k/a/ ORTEC, a subsidiary of AMETEK, Inc. WARRANTY

More information

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1225 ParaLink TM Parallel Short Range Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1225-B Doc. #104011UB Revised 9/12/97 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 - HOUSTON TX 77041-8943 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU MODEL DSU-56SA 56 Kbps Stand Alone CSU/DSU OPERATOR S MANUAL 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439 Tel: 775-345-8000 Fax: 775-345-8010 E-mail: support @sgdi.net DSU-56SA TABLE OF CONTENTS SECTION

More information

HDTVMT User Manual

HDTVMT User Manual HDTVMT0808140 User Manual HDTV Supply, Inc. Contact: support@hdtvsupply.com 1 Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully before

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

General and Copyright Notice Warranty OmniConverter Limitation of Warranty Environmental Notices User Manual

General and Copyright Notice Warranty OmniConverter Limitation of Warranty Environmental Notices User Manual OmniConverter GPoE+/Sx Unmanaged 8-Port PoE/PoE+ Switch User Manual General and Copyright Notice This publication is protected by U.S. and international copyright laws. All rights reserved. The whole or

More information

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter USER MANUAL MODEL 505M-CHC Surge Protected DB-25 to RJ-45 Modular Adapter C E R T I F I E D An ISO-9001 Certified Company Part# 07M505MCHC-A Doc# 074281U, Rev. B Revised 1/21/08 SALES OFFICE (301) 975-1000

More information

Broadband Automatic Disconnect Switch. User Manual

Broadband Automatic Disconnect Switch. User Manual Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction

More information

4x4 DVI Dual Link Matrix

4x4 DVI Dual Link Matrix 4x4 DVI Dual Link Matrix EXT-DVI-444DL User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to

More information

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual. BDM Rev. C

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual. BDM Rev. C CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule User s Manual BDM-610020066 Rev. C ISO9001 and AS9100 Certified CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s Twisted

More information

MEC-USB-M002. User s Manual

MEC-USB-M002. User s Manual MEC-USB-M002 Mini PCI-e 2-port USB 3.0 board User s Manual Third Edition, February 2014 2014 Cervoz Co., Ltd. All rights reserved. Reproduction without permission is prohibited Mini PCI-e USB Card User

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS TTL Driver Boards for 3200 & 3250 Series Programmable Attenuators (P/N 101-1704-000, 101-1705-000, 101-1798-000, 101-1798-001 & 101-1804-000) This documentation may

More information

PIM-Mini Pulsed Current Source Operation Manual

PIM-Mini Pulsed Current Source Operation Manual PIM-Mini Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0007

More information

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual SmartBoom Operating Manual PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U Thank You We at Pliant Technologies, LLC want to thank you for purchasing the SmartBoom PRO

More information

OPERATIONS MANUAL PCM-DOC

OPERATIONS MANUAL PCM-DOC OPERATIONS MANUAL PCM-DOC NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual

More information

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan SP-1009D 1x9 Dual Link DVI Distribution Amplifier User Manual Made in Taiwan Safety and Notice The SP-1009D 1x9 Dual Link DVI Distribution Amplifier has been tested for conformance to safety regulations

More information

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem USER MANUAL MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem An ISO-9001 Certified Company Part #07M1003-B Doc. #050021UB Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL

More information

USB HD Audio/Video Codec Model 2263 Hardware Manual Ver October 2013

USB HD Audio/Video Codec Model 2263 Hardware Manual Ver October 2013 USB HD Audio/Video Codec Model 2263 Hardware Manual Ver.1.0.1 October 2013 Table of Contents LIMITED WARRANTY...3 SPECIAL HANDLING INSTRUCTIONS...4 INTRODUCTION...5 SYSTEM REQUIREMENTS...5 BLOCK DIAGRAM...6

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 45

OPERATING AND SERVICE MANUAL. Universal Interface Device 45 OPERATING AND SERVICE MANUAL Universal Interface Device 45 MAGNA-POWER ELECTRONICS, INC. 81 FULTON STREET, BOONTON, NJ 07005 September 7, 2005 SAFETY NOTICE Universal Interface Device 45 (UID45) connects

More information

USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply

USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply 26 Ward Hill Ave., Bradford, MA 01835 Phone: 978-241-8260 Fax: 978-241-8262 USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply 02001235 Rev 1 CCHP-6000-XX User Manual Page 1 of 14 Table of

More information

User Guide DMX TESTER

User Guide DMX TESTER User Guide DMX TESTER Document Release Aug. 2006 Revision A Warranty Leviton Manufacturing Co Inc. warrants this control console to be free of material and workmanship defects for a period of two years

More information

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL REVISION: 01/05/03 COPYRIGHT (c) 1987-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The MD9 MULTIDROP INTERFACE is warranted by

More information

User Manual rev: Made in Taiwan

User Manual rev: Made in Taiwan SP-1014 1x4 DVI Splitter over Single Cat.X with HDCP Support User Manual rev: 111209 Made in Taiwan The SP-1014 1x4 DVI Splitter over Single Cat.X with HDCP Support has been tested for conformance to safety

More information

CRS :10 Redundancy Switch Installation and Operation Manual

CRS :10 Redundancy Switch Installation and Operation Manual CRS-300 1:10 Redundancy Switch Installation and Operation Manual IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product

More information

Thank you for selecting Instrument Technology, Inc. (ITI) to fulfill your remote viewing needs.

Thank you for selecting Instrument Technology, Inc. (ITI) to fulfill your remote viewing needs. INTRODUCTION Thank you for selecting Instrument Technology, Inc. (ITI) to fulfill your remote viewing needs. Since 1967, ITI has been the Leader in Remote Viewing. ITI consistently provides cutting edge

More information

FTC-200 X-ray Tube Controller Users Manual

FTC-200 X-ray Tube Controller Users Manual Tubes FTC-200 X-ray Tube Controller TUB-MAN-2101 Rev. A 09/09/2009TTUB Table of Contents List of Tables...3 List of Figures...3 Introduction...3 Manual Set...3 About this Manual...4 X-Ray Safety Information...4

More information

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849

More information