RC E User Manual

Size: px
Start display at page:

Download "RC E User Manual"

Transcription

1 RC E

2 Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Raisecom Technology Co., Ltd shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Warranty. A copy of the specific warranty terms applicable to your Raisecom product and replacement parts can be obtained from Service Office. Restricted Rights Legend. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Raisecom Technology Co., Ltd. The information contained in this document is subject to change without notice. Copyright Notices. Copyright 2007 Raisecom. All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in Writing from Raisecom Technology Co., Ltd. Trademark Notices is the trademark of Raisecom Technology Co., Ltd. Java is a U.S. trademark of Sun Microsystems, Inc. Microsoft is a U.S. registered trademark of Microsoft Corporation. Windows NT is a U.S. registered trademark of Microsoft Corporation. Windows 2000 is a U.S. registered trademark of Microsoft Corporation. Windows XP is a U.S. registered trademark of Microsoft Corporation. Windows and MS Windows are U.S. registered trademarks of Microsoft Corporation.

3 Contact Information Technical Assistance Center The Raisecom TAC is available to all customers who need technical assistance with a Raisecom product, technology, or, solution. You can communicate with us through the following methods: Address: 2 nd Floor, South Building of Rainbow Plaza, No.11 Shangdi Information Road, Haidian District, Beijing Tel: Fax: World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL: Feedback Comments and questions about how the RC E device works are welcomed. Please review the FAQ in the related manual, and if your question is not covered, send by using the following web page: If you have comments on the device specification, instead of the web page above, please send comments to: export@raisecom.com We hope to hear from you!

4 CONTENTS Release Notes General Safety Instructions Safety Symbols Handling Energized Products General Safety Practices Connection of AC Mains Connection of DC Mains Preventing Electrostatic Discharge Damage Chapter 1 Product Overview Overview Function Features Ordering information Chapter 2 Technical Specifications Technical specifications of E1 interface Technical specifications of the optical interface The properties of the Agent network management interface Power supply Operating environment Storing environment Outline and structure Chapter 3 Device Appearance and Descripiton Device front panel Device rear panel Indicator Description Interface description Expansion slot description Chapter 4 Device Settings DIP switch description The location of the DIP switches DIP switch description Default settings Chapter 5 Basic Connection and Typical Application Basic Connection Connect the optical interface Connect the Agent network management interface Connect to the power supply Typical application Chapter 6 Network Management Features Network management platform Network management query Network management configuration Chapter 7 Device Installation Preparation and Connection Pre-installation checking and preparing Make sure that the cable applied matches the sub-cards on the device Make sure that the fiber applied matches the requirement of the device Confirm the fiber cable type applied Installation procedures Device installation Cable connection Device electrifying Appendix A Cable Making A.1 PC-Agent network management cable making Appendix B FAQ

5

6 Release Notes Date of Release Manual Version Revisions REV.A

7 General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel. Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines. Protective earth: the marked lug or terminal should be connected to the building protective earth bus. Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached. Please observe the following precautions: Before turning on the chassis with optic module, make sure that the fiber optic cable is intact and is connected to the transmitter. Do not attempt to adjust the laser drive current. Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam. The use of optical devices with the equipment will increase eye hazard. Use of controls, adjustments or performing procedures other than those specified herein, may result in hazardous radiation exposure. ATTENTION: The laser beam may be invisible! Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user. All extension slots are not hot-swappable Before operating modules in the electricity conditions, please be noticed that optical transceivers shall be connected with optical fiber wires or shield with optical transceiver cover for fear that laser light harms to operator s eyes. Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages may

8 be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist. Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts. Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is provided on the product, it should be connected to the protective earth at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and cabinets. Always make the ground connection first and disconnect it last. Do not connect telecommunication cables to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the ground. Connection of AC Mains Make sure that the electrical installation complies with local codes. Always connect the AC plug to a wall socket with a protective ground. Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation. Connection of DC Mains Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded. Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards. DC units should be installed in a restricted access area, i.e. an area where access is authorized only to qualified service and maintenance personnel. Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes. Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation. Preventing Electrostatic Discharge Damage Modules which can be plugged into chassis are sensitive to damage from static electricity. Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper electrostatic discharge (ESD) precautions can result in intermittent or complete component failures. To minimize the potential for ESD damage, observe the following guidelines: Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good skin contact. When removing or installing a component, make sure the equipment end of your antistatic strap leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal surface on the chassis. Avoid contact between the component and your clothing. The wrist strap only protects the component from ESD voltages on the body; ESD voltages on your clothing can still cause component damage. Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a static shielding bag. If you are returning the item to the factory, immediately place it in a static shielding bag. Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector pins.

9 Chapter 1 Product Overview 1.1 Overview RC E series multi-service standalone PDH multiplexer is a fiber optic transmission device applicable to point-to-point network or network with small or medium capacity, like wireless communication base station, private networks, switch network and etc. RC E series multi-service PDH multiplexer realizes the transmission of at most 8 lines of E1 service on 1 line of fiber. For the E1 tributary interface, RC E provides 4 expansion slots. Together with Raisecom s E1 service sub-card, V.35 service sub-card, Ethernet service sub-card or other services sub-cards, various multi-service configuration solutions can be flexibly realized with RC E to meet customers requirements. RC E multi-service PDH multiplexer can be deployed in a point-to-point application with other PDH devices, like RC831/2 series devices, developed by Raisecom. 1.2 Function Features 8*2Mbps (E1, V.35, Fast-Ethernet and etc.) transmission capability Provides 4 expansion slots Provides multi-service interfaces with V.35 sub-card, Fast Ethernet sub-card and E1 sub-card in the expansion slots. Indication for both local and remote site alarm information and status information. Optical interface alarm information and the working status of all E1s of both local and remote devices can be displayed at the same time Remote device power-off detection and alarm notification At most 8 E1 interfaces working at 2048Kbps transparent transmission mode ALS function is supported to effectively control the output of optical signal in no connection status Local and remote E1 tributary loopback testing function makes fault removal and maintenance easier Local and remote network management In support of SNMP network management In support of software online upgrade Adopt grand-scale ASIC chip Low power consumption 4-layer circuit board design guarantees high reliability. 1.3 Ordering information Device Model RC E-S1 Description Stand-alone device, 8 lines of E1 service provided by 4 expansion slots in which sub-cards like E-SUBM-FV35, E-SUBM-2FV35, E-SUBM-2FE, E-SUBM-FE4E1, E-SUBM-2E1, E-SUBM-4E1-BL, and etc. can be inserted, 1 optical interface, dual-strand, single-mode (DSC/PC), transmission distance 0~25km, single power supply, AC 1

10 or DC power supply RC E-S2 RC E-S3 RC E-SS13 RC E-SS15 RC E-SS23 RC E-SS25 Stand-alone device, 8 lines of E1 service provided by 4 expansion slots in which sub-cards like E-SUBM-FV35, E-SUBM-2FV35, E-SUBM-2FE, E-SUBM-FE4E1, E-SUBM-2E1, E-SUBM-4E1-BL, and etc. can be inserted, 1 optical interface, dual-strand, single-mode (DSC/PC), transmission distance 10~60km, single power supply, AC or DC power supply Stand-alone device, 8 lines of E1 service provided by 4 expansion slots in which sub-cards like E-SUBM-FV35, E-SUBM-2FV35, E-SUBM-2FE, E-SUBM-FE4E1, E-SUBM-2E1, E-SUBM-4E1-BL, and etc. can be inserted, 1 optical interface, dual-strand, single-mode (DSC/PC), transmission distance 15~120km, single power supply, AC or DC power supply Stand-alone device, 8 lines of E1 service provided by 4 expansion slots in which sub-cards like E-SUBM-FV35, E-SUBM-2FV35, E-SUBM-2FE, E-SUBM-FE4E1, E-SUBM-2E1, E-SUBM-4E1-BL, and etc. can be inserted, 1 optical interface, single-strand, single-mode (SC/PC), TX wavelength 1310nm, RX wavelength 1550nm, transmission distance 0~25km, single power supply, AC or DC power supply Stand-alone device, 8 lines of E1 service provided by 4 expansion slots in which sub-cards like E-SUBM-FV35, E-SUBM-2FV35, E-SUBM-2FE, E-SUBM-FE4E1, E-SUBM-2E1, E-SUBM-4E1-BL, and etc. can be inserted, 1 optical interface, single-strand, single-mode (SC/PC), TX wavelength 1550nm, RX wavelength 1310nm, transmission distance 0~25km, single power supply, AC or DC power supply Stand-alone device, 8 lines of E1 service provided by 4 expansion slots in which sub-cards like E-SUBM-FV35, E-SUBM-2FV35, E-SUBM-2FE, E-SUBM-FE4E1, E-SUBM-2E1, E-SUBM-4E1-BL, and etc. can be inserted, 1 optical interface, single-strand, single-mode (SC/PC), TX wavelength 1310nm, RX wavelength 1550nm, transmission distance 10~50km, single power supply, AC or DC power supply Stand-alone device, 8 lines of E1 service provided by 4 expansion slots in which sub-cards like E-SUBM-FV35, E-SUBM-2FV35, E-SUBM-2FE, E-SUBM-FE4E1, E-SUBM-2E1, E-SUBM-4E1-BL, and etc. can be inserted, 1 optical interface, single-strand, single-mode (SC/PC), TX wavelength 1550nm, RX wavelength 1310nm, transmission distance 10~50km, single power supply, AC or DC power supply 2

11 Note: The factual models of the stand-alone devices should have suffixes that describe the power supply of the devices. For example: RC E-S1-AC indicates device with 220V AC power supply, while RC E-S1-DC indicates device with -48V DC power supply. The devices that can communicate with RC E series devices are listed in the table below. Client Site Device RC E-S1 CO Site Device RC E-S1 RC831/2-240-S1 RC E-S2 RC E-S2 RC831/2-240-S2 RC E-S3 RC E-S3 RC831/2-240-S3 RC E-SS13 RC E-SS15 RC831/2-240-SS15 RC E-SS15 RC E-SS13 RC831/2-240-SS13 RC E-SS23 RC E-SS25 RC831/2-240-SS25 RC E-SS25 RC E-SS23 RC831/2-240-SS23 3

12 Chapter 2 Technical Specifications 2.1 Technical specifications of E1 interface Bit rate: 2048Kbps±50ppm Coding: HDB3 Frame format: comply with ITU-T G.704 recommendations Physical characteristic: comply with ITU-T G.703 recommendations Transfer characteristic: comply with ITU-T G.823 recommendations Jitter tolerance: comply with ITU-T G.823 recommendations 2.2 Technical specifications of the optical interface Bit rate: 150Mbps Line coding: scrambled NRZ Interface type: SC interface Optical transmission parameter: different optical transceivers have different optical interface parameters, please see the table below. Optical transceiver Wavelength (nm) LASER Type Receiver Transmitting Optical Power (dbm) Overload (dbm) Receiving Sensibility (dbm) Transmission Distance (Km) S FP PIN -15, -8 > -8 < ~ 25 S FP PIN -5, 0 > -8 < ~ 60 S DFB PIN -5, 0 > -10 < ~ 120 SS FP PIN -12, -3 > -8 < ~ 25 SS FP/DFB PIN -12, -3 > -8 < ~ 25 SS FP PIN -5, 0 > -8 < ~ 50 SS DFB PIN -5, 0 > -8 < ~ 50 Note: The transmission distance in the table indicates the maximal transmission distance in typical optical fiber condition. The transmission distance that can be realized depends on the factual status of the network. 2.3 The properties of the Agent network management interface Interface type: RJ-45 Standard Compliance: RS232 Bit rate: 19200bps 4

13 2.4 Power supply AC power supply Voltage: 220V Allowance: 175 ~ 265V Frequency: 50Hz or: Voltage: 110V/230V Allowance: 85 ~ 265V Frequency: 50Hz/60Hz DC power supply Voltage: -48V Allowance: -36 ~ -72V OR: Voltage: +24V Allowance: +18 ~ +36V Power consumption: < 3W (without sub-card) Note: The device power consumption in the table indicates the maximal power consumption of the device when it is operating with no modules. The factual power consumption of the device depends on the model and number of modules applied. 2.5 Operating environment Operating temperature: 0 ~ 60 Operating humidity: 90% (25 ) 2.6 Storing environment Storing temperature: -40 ~ 80 Storing humidity: 5% ~ 90%, no condensation 2.7 Outline and structure Physical outline: 19 stand-alone device, 1U in height Dimension: 43.6mm (Height) x 440mm (Width) x 300mm (Depth) Net Weight: < 4Kg 5

14 Chapter 3 Device Appearance and Descripiton 3.1 Device front panel Figure 3-1 The front panel of RC E with AC power supply Figure 3-2 The front panel of RC E with DC power supply 3.2 Device rear panel Figure 3-3 The rear panel of RC E 3.3 Indicator Description Power supply and system working status indicator: PWR (Green): ON: the power supply is working properly OFF: the power supply for the device is cut off LPR (Red): ON: remote device power down OFF: the power supply for the remote device is operating in order Optical interface alarm indicator: L-LOS (Red): ON: loss of receiving signal (LOS) alarm at the local optical interface R-LOS (Red): ON: loss of receiving signal (LOS) alarm at the remote optical interface 6

15 L-LOF (Red): ON: loss of frame (LOF) alarm at the local optical interface R-LOF (Red): ON: loss of frame (LOF) alarm at the remote optical interface L-E-3 (Red): ON: the receiving signal bit error rate (BER) at the local optical interface exceeds 1E-3 R-E-3 (Red): ON: the receiving signal BER at the remote optical interface exceeds 1E-3 L-E-6 (Yellow): ON: the receiving signal BER at the local optical interface exceeds 1E-6 R-E-6 (Yellow): ON: the receiving signal BER at the remote optical interface exceeds 1E Interface description E1 signal connection status indicator: L-E1 USED (1~8) (Green): ON: the local E1 tributary 1~8 are well connected OFF: loss of receiving signal alarm occurs at the local E1 tributary 1~8 R-E1 USED (1~8) (Green): ON: the remote E1 interface 1~8 are well connected OFF: loss of receiving signal alarm occurs at the remote E1 tributary 1~8 Optical interface: For device models with optical transceivers using dual-strand optical transceivers, the optical interface is DSC/PC interface. TX indicates optical signal output. RX indicates optical signal input. For device models with optical transceivers using signal-strand optical transceivers, the optical interface is SC/PC interface. Network management interface: LNK-UP Local network management interface or cascade interface. Connect to the serial port of the PC for network management or connect to the LNK-DWN interface of the device on the higher level in the cascade. It is a RJ-45 interface. Comply with RS232 electrical level standard. The port will be working at the rate of 19200bps. LNK-DWN Cascade interface. Connect to the LNK-UP interface of the device on the lower level of the cascade. Comply with RS232 electrical level standard. The port will be working at the rate of 19200bps. Note: 1. When the software online upgrade function is enabled, the connection of the LNK-UP interface and the serial port of the PC or the connection of the LNK-UP interface with the LNK-DWN interface on the device on the higher level is only for the use of software online upgrade. In this circumstance, the network 7

16 management function is inapplicable. 2. For the pin arrangement of the cable connecting the LNK-UP interface and the serial port of the PC, please refer to Appendix A For the connection of an LNK-UP interface and an LNK-DWN interface, please use RJ-45-RJ-45 flat straight-through cable. Power supply interface: AC power supply interface The AC power supply interface is a 3-phase AC power supply interface. Please make sure that the power supply of the device is well earthed. For AC power supply without grounding terminal, please connect the grounding terminal on the right of the device with the protection earth of the device room. DC power supply interface The DC power supply interface has 3 terminals: -48V, PGND and BGND. Please make sure that the PGND terminal is connected to the protection earth. Note that the grounding terminal on the right of the device and the PGND terminal of the DC power supply are connected in the device, and please be sure that one of them is well connected to the protection earth. 3.5 Expansion slot description RC E has 4 expansion slots, and they are titled SLOT1, SLOT2, SLOT3 and SLOT4. Various expansion sub-cards can be inserted into these expansion slots to provide excellent configuration flexibility, and to meet different requirements from customers. The table below lists some typical configurations: Slot Number SLOT1 SLOT2 SLOT3 SLOT4 Maximum Transmission Capacity 4 E1 2 E1 4 E1 2 E1 E1 Line Occupation E1 1~4 E1 3~4 E1 5~8 E1 7~8 Multi-service Configuration Example E-SUBM-FV35 (occupies E1 1) E-SUBM-FV35 (occupies E1 3) E-SUBM-FV35 (occupies E1 5) E-SUBM-FV35 (occupies E1 7) E-SUBM-2FV35 E-SUBM-2FV35 E-SUBM-2FV35 E-SUBM-2FV35 (occupies E1 1~2) (occupies E1 3~4) (occupies E1 5~6) (occupies E1 7~8) E-SUBM-2E1 E-SUBM-2E1 E-SUBM-2E1 E-SUBM-2E1 (occupies E1 1~2) (occupies E1 3~4) (occupies E1 5~6) (occupies E1 7~8) E-SUBM-2FE E-SUBM-2FE E-SUBM-2FE E-SUBM-2FE (occupies E1 1~2) (occupies E1 3~4) (occupies E1 5~6) (occupies E1 7~8) E-SUBM-FE4E1 E-SUBM-FE4E1 8

17 (occupies E1 1~4) (occupies E1 5~8) E-SUBM-4E1-BL (occupies E1 1~4) E-SUBM-4E1-BL (occupies E1 5~8) Note: When the sub-cards in the expansion slot SLOT1 and SLOT3 are sub-cards that occupy 4 lines of E1, the expansion slot SLOT2 and SLOT4 can not be used. 9

18 Chapter 4 Device Settings 4.1 DIP switch description The location of the DIP switches DIP switch description The DIP switches are placed on the front panel of RC E, please see the figures that shows the device front panel. There are 2 DIP switches on the front panel of the device: SW1 and SW2. For SW1, the 8 bits from the left to the right are bit 1~8. When a bit of the switch is turned to the lower side, it means that the bit is turned ON. When a bit of the switch is turned to the upper side, it means that the bit is turned OFF. Function setting switch SW1: Definition OFF ON Bit 1 Bit 2 Bit 3 Bit 4 LOOP1 LOOP2 LOOP3 LOOP4 Loopback control switch Bit 5 Loopback point Remote E1 loopback Local E1 loopback Bit 6 Reserved Default status Bit 7 ALS function Disable Enable Bit 8 Software online upgrade Disable Enable Bit 1~4: loopback control switch Bit 1 Bit 2 Bit 3 Bit 4 Loopback control OFF OFF OFF OFF No E1 loopback OFF OFF OFF ON E1 1 loopback OFF OFF ON OFF E1 2 loopback OFF OFF ON ON E1 3 loopback 10

19 OFF ON OFF OFF E1 4 loopback OFF ON OFF ON E1 5 loopback OFF ON ON OFF E1 6 loopback OFF ON ON ON E1 7 loopback ON OFF OFF OFF E1 8 loopback ON ON ON ON All E1 loopback Note: The loopback control function provides two ways of loopback testing: single E1 loopback or all E1 loopback. When conducting single loopback testing, the communication of other E1 lines will not be affected. For the status combinations of Bit 1~4 that are not listed in the table above, there will be no E1 loopback. Bit 5: loopback point selection switch When setting loopback testing using the first 4 bits of SW1, Bit 5 of SW1 is used for selecting the loopback point, that is, deciding whether the loopback is a remote loopback or a local one. The loopback point of the remote E1 loopback and local E1 loopback are shown in the Figure 4-1 and Figure 4-2, respectively. Bit 5 OFF ON Loopback point selection Remote E1 loopback Local E1 loopback Figure 4-1 The settings of remote loopback on the local PDH multiplexer BER Tester E1 Sid e Fiber Remot Local e Figure 4-2 The settings of the local loopback on the local PDH multiplexer E1 Sid e 11

20 Note: 1. Before setting up the remote E1 loopback testing, please make sure that there is no alarm at the optical interface. 2. To set up any loopback on the local PDH multiplexer, the loopback settings of the remote device must by NO loopback. Bit 6: Reserved Bit 7: Auto-Laser-Shutdown (ALS) function switch Bit 7 OFF ON ALS function Disable Enable When the Auto-Laser-Shutdown function is enabled, the TX of the optical transceiver will be shut down if loss of receiving signal alarm occurs at the optical interface. Bit 8: software online upgrade function switch Bit 8 OFF ON Software online upgrade function Disable Enable When the software online upgrade function is enabled, users can upgrade the software on the device at the local site via serial COM port of a PC. The software online upgrade function makes device maintenance and upgrade easier. For a RC E device under regular use, please do not change the status of the switch and keep its default setting (OFF). Otherwise, the improper setting of the switch may lead to operation abnormity. Note: Before electrifying the device, please make sure that the status of SW1 Bit 8 is OFF. Otherwise, the device can not start properly. Address code setting switch SW2: When the 4 bits of the address code setting switch SW2 are all OFF, the device can be managed as a remote device. Otherwise, the device can be managed by the serial port of a local PC via the LNK-UP interface on the device. Different device in the cascade of one serial port must have different address code. For the 4-bit DIP switch SW2, the 4 bits from the left to the right are bit 1~4. At most 15 devices are allowed to be in one local cascade. The table below lists the relationship between the settings of SW2 and the address code of the device. 12

21 Bit 1 Bit 2 Bit 3 Bit 4 Address Code OFF OFF OFF OFF Remote device OFF OFF OFF ON Local device 1 OFF OFF ON OFF Local device 2 OFF OFF ON ON Local device 3 OFF ON OFF OFF Local device 4 OFF ON OFF ON Local device 5 OFF ON ON OFF Local device 6 OFF ON ON ON Local device 7 ON OFF OFF OFF Local device 8 ON OFF OFF ON Local device 9 ON OFF ON OFF Local device 10 ON OFF ON ON Local device 11 ON ON OFF OFF Local device 12 ON ON OFF ON Local device 13 ON ON ON OFF Local device 14 ON ON ON ON Local device Default settings The factory settings of all DIP switches are OFF. This default setting of the device indicates that: The device is a remote device. The ALS function is disabled. No E1 local/remote loopback. The software online upgrade function is disabled. 13

22 Chapter 5 Basic Connection and Typical Application 5.1 Basic Connection Connect the optical interface Insert the well-prepared fiber patch cord into the optical interface on the front panel of the device. The optical interface connection pattern is shown in Figure 5-1. Figure 5-1 The connection of the optical interface Connect the Agent network management interface When connecting the device with the PC for network management, please connect the RJ-45 connector of the CBL-PCAGENT-DB9F/RJ45 cable to the LNK-UP interface of the device and connect the DB-9 connector of the cable to the serial port of the PC Connect to the power supply For device adopting 220V AC power supply, please plug the provided 220V AC power supply cable to a 220V standard 3-phase power supply socket. For device adopting -48V DC power supply, please connect the device with DC power supply using -48V DC power supply (connect the BGND terminal of the DC power supply interface of the device to the earth of the power supply, connect the -48V terminal to the -48V power supply, and connect the PGND terminal to protection earth). For device using +24V or -24V DC power supply, the connecting is similar to that of the -48V DC power supply. 14

23 5.2 Typical application Figure 5-2 Point-to-point application 15

24 Chapter 6 Network Management Features 6.1 Network management platform The status information of RC E can be viewed on Raisecom s network management platform NView NNM V5.0. Users can also control and configure the device on the network management platform. 6.2 Network management query All indicator status information and expansion slot occupation status information of local/remote RC E can be displayed on the network management platform. Users can query the working status information and alarm information of the local/remote RC E and the sub-cards in the expansion slots of the device. 6.3 Network management configuration Users can change the function settings completed by DIP switches except for the local/remote device address code setting and software online upgrade function setting on the network management platform. Note: The latest configuring operation, whether it is completed by the network management system or a DIP switch, will always take effect. 16

25 Chapter 7 Device Installation Preparation and Connection 7.1 Pre-installation checking and preparing Firstly, please check the model and the number of the device and spare parts according to the packing list. Please be sure that the appearance of the device is intact. If there is any evidence that the device has been affected by damp, please dry it before installation. Please read this manual with caution before installing the device; please have all types of cables that are needed ready and make sure there are no short circuits and open circuits; please make sure that the power supply of the chassis works in the operating voltage range; please have the rack of the chassis device well earthed; please prepare bit error rate tester, optical power meter for line quality testing; please fix the device on to a 19-inch rack or place it on a safe and stable place, please be cautious of the environment requirement of the device Make sure that the cable applied matches the sub-cards on the device The 4 expansion slots on RC E support various service sub-cards. Before electrifying the device, please make sure that the cable applied matches the sub-card model on the device. For detailed information, please refer to the user manual of the corresponding sub-card Make sure that the fiber applied matches the requirement of the device For RC E-M, please use multi-mode fiber with SC/PC connector. For RC E-S1/S2/S3, please use single-mode fiber with SC/PC connector. For RC E-SS13/SS15/SS23/SS25, please use single-mode fiber with SC/PC connector Confirm the fiber cable type applied The cable type for the interface of multi-mode fiber: 62.5/125um multi-mode fiber or 50/125um multi-mode fiber The cable type for the interface of single-mode fiber: 9/125um single-mode fiber 7.2 Installation procedures Device installation Firstly, please set the DIP switches of the sub-cards according to need, insert the sub-cards into the expansion slots slowly and carefully and tighten the screws. Then, please fix the device onto a 19-inch rack or place it on a stable and safe place. Please make sure that the installation environment meets the requirement of the device Cable connection Optical interface: 17

26 Please insert the SC patch cord into the optical interface and make sure that the connector touches the bottom of the interface. If the TX and RX direction of the optical signal is not known, users can connect the optical interface after electrifying the device. Network management interface: Please connect the LNK-UP interface with the serial port of PC. If there are several PDH multiplexers in the cascade of the serial port, please connect the LNK-DWN interface of the device on the higher level in the cascade with the LNK-UP interface of the device on the lower level in the cascade, and the LNK-DWN interface on the last device in the cascade will have no connection. After connecting all the cables, please set the address code for all the devices in the cascade following the instructions for setting SW2. Different PDH multiplexer in the cascade of one serial port must have different address code. Service interfaces on sub-cards: For different sub-cards, please use cables corresponding to the sub-cards applied. For details, please refer to the user manuals of sub-cards Device electrifying For device using -48V DC power supply, please connect the PGND terminal to the protection earth first. Before electrifying the power supply cable, please connect the -48V terminal with power supply cable with lower electrical potential and connect the BGND terminal with power supply cable with higher electrical potential. Please tighten the connection and make sure there is no short circuit, and then turn on the power supply. For device using 220V AC power supply, please use the power supply cable provided with the device to connect the device to 220V AC power supply. After electrifying the device, the power supply status indicator PWR (Green) on the front panel of the device will turn ON to show that the power supply is working normally. The device will begin to initialize and self-check after electrifying. The process will take no more than 10 seconds. During the initialization and self-checking, the optical interface status indicator LOF and E-6 may flicker for one time, which is a normal phenomenon. The system will begin its normal operation after 10 seconds. During the operation, please make sure the optical interface is well connected. If the optical interface is correctly connected, there will be no LOS, LOF, E-3, and E-6 alarms. 18

27 Appendix A Cable Making A.1 PC-Agent network management cable making For PC-Agent network management, please use flat straight-through cable with RJ-45 connector. The RJ-45 connector and its pin arrangement are shown in Figure A-1, Table A-1 and Table A-2 respectively. Figure A-1 The pin arrangement of RJ-45 crystal connector (top view) Table A-2 Pin arrangement of LNK_UP interface Pin Number Definition NC NC IN GND NC NC OUT GND Table A-3 Pin arrangement of the LNK_DWN interface Pin Number Definition NC NC OUT GND NC NC IN GND Figure A-2 shows the connecting rule of the LNK-UP interface (RJ-45) and the serial port of PC (DB-9 female). Figure A-2 The connection of the device and the serial port of the PC For the connection of a LNK-DWN interface (RJ-45) to a LNK-UP interface (RJ-45), please use straight-through cable. 19

28 Appendix B FAQ For some problems you may meet during installation and operation, please try to solve them following the suggestions below. For the problems can not be solved using the following suggestions, please contact with distributors for technical support. The power supply indicator PWR (green) wouldn t turn ON. Please check whether the power supply cable of the device is well connected and whether the power supply switch has been turned on. The optical interface LOS indicator (red) turns ON. This indicates that loss of receiving signal (LOS) alarm occurs at the optical interface. Firstly, please check whether the fiber is well connected to the optical interface. Secondly, please form a self loop using the fiber (may need attenuation). If the alarm still exists, please replace the fiber and again form a self loop using the new fiber. If the optical interface LOS indicator is still ON, there is problem with the device. The optical interface LOF indicator (red) turns ON. Loss of frame alarm of the receiving signal at the optical interface occurs. Optical signal has been received, but the optical power may be around the critical receiving sensitivity. Please measure the receiving optical power and make sure that the TX interface of the optical interface of the remote device has been well connected. Optical interface indicator E-3 (red) turns ON. The bit error rate of the receiving signal at the optical interface exceeds 1E-3. Please check whether the optical interface has been well connected and please measure the receiving optical power as well. Optical interface indicator E-6 (yellow) turns ON. The bit error rate of the receiving signal at the optical interface exceeds 1E-6. The E-6 alarm may occur when the device is just electrified. This is a normal phenomenon and will last at most 10 seconds before the E-6 indicator turns OFF. If the E-6 alarm occurs during the normal operation of the device, please check whether the optical interface is well connected and please measure the optical power. 20

29 Address: 2 nd Floor, South Building of Rainbow Plaza, No.11 Shangdi Information Road, Haidian District, Beijing Postcode: Tel: Fax: export@raisecom.com

RC832-30(-BL) User Manual

RC832-30(-BL) User Manual RC832-30(-BL) Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for

More information

RC952-FEDS3/E3 Modular DS3/E3 Interface Converter User Manual

RC952-FEDS3/E3 Modular DS3/E3 Interface Converter User Manual RC952-FEDS3/E3 Modular DS3/E3 Interface Converter Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties

More information

RC702-FX Ethernet over SDH User Manual

RC702-FX Ethernet over SDH User Manual RC702-FX Ethernet over SDH User Manual Raisecom Technology Co., Ltd 1. Caution Please carefully read the following precautions before installing and deploying RC702-FX equipment, and operate strictly according

More information

RC954 Series Modular Inverse Multiplexer User Manual

RC954 Series Modular Inverse Multiplexer User Manual www.raisecom.com RC954 Series Modular Inverse Multiplexer User Manual 200704 Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited

More information

Datasheet RCMS2801 FE Series Multi-service PDH Optical Multiplexer

Datasheet RCMS2801 FE Series Multi-service PDH Optical Multiplexer RCMS2801 FE Series Multi-service PDH Optical Multiplexer RCMS2801 is a series ideal standalone transmission device of optical fiber for point-to-point networks, medium-sized and small capacity networks,

More information

RCMS Modular Optical Multiplexer Manual

RCMS Modular Optical Multiplexer Manual RCMS2404-240 Modular Optical Multiplexer Manual Beijing Raisecom science & technology Co. Ltd Content Chapter 1 Overview... 1 Chapter 2 Technical characteristic... 2 Chapter 3 Instruction... 3 Chapter

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

Datasheet RCMS2802 FE Series Multiservice PDH Optical Multiplexer

Datasheet RCMS2802 FE Series Multiservice PDH Optical Multiplexer RCMS2802 is a series ideal modular transmission device of optical fiber for point-to-point networks, medium-sized and small capacity networks, such as wireless communication base stations, private communication

More information

RC701/RC702-FE series Ethernet over SDH devices User Manual

RC701/RC702-FE series Ethernet over SDH devices User Manual RC701/RC702-FE series Ethernet over SDH devices User Manual Raisecom Technology Co., Ltd 1. Cautions Warning: Only trained and qualified personnel should be allowed to install, replace or service this

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd. Multi-Service Access Platform OPCOM3500E-12 OPCOM3500E-12 Feature Overview OPCOM3500E MSAP is carrier-class Multi-Service Access Platform, and designed to enable establishment of service-integrated for

More information

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide Industrial Serial RS-232 to Fiber Converter KSC-200 Series Installation Guide DOC.100803-KSC-200-1- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any

More information

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO F8016 Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO Description The fiber transmission platform is a fiber optic multiplexer with a fully new designing concept to challenge

More information

RC414 Universal Optical Converter/Repeater User Manual

RC414 Universal Optical Converter/Repeater User Manual RC414 Universal Optical Converter/Repeater User Manual Beijing Raisecom Science & Technology Co., Ltd 10/2005 1. Cautions Please read the following notices carefully before installing and using the device,

More information

RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter. User Manual. Raisecom Technology Co., Ltd.

RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter. User Manual. Raisecom Technology Co., Ltd. RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter User Manual Raisecom Technology Co., Ltd. Dec, 2005 CONTENT 1. SAFETY NOTICE...2 2. OVERVIEW...3 2.1. MODEL DESCRIPTION...3

More information

User Manual. RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter

User Manual. RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter User Manual Beijing Raisecom Science & Technology Co., Ltd Contents Chapter 1 RC511/RC512-FE-XX(Rev.A)Series

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Datasheet RCMS2802 GE series Multiservice PDH Optical Multiplexer

Datasheet RCMS2802 GE series Multiservice PDH Optical Multiplexer RCMS2802 is a series ideal transmission device of optical fiber for point-to-point networks, medium-sized and small capacity networks, such as wireless communication base stations, private communication

More information

Quick Start Guide. C-100 Series Switches

Quick Start Guide. C-100 Series Switches Quick Start Guide C-100 Series Switches C-100 SERIES QUICK START GUIDE Warnings and Cautionary Messages!! Warning: This product does not contain any serviceable user parts. Warning: Installation and removal

More information

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd V C ALIANT OMMUNICATIONS VCL-4 E1 + Ethernet PDH Optical Multiplexer Data Sheet U.K. Valiant Communications (UK) Ltd Central House Rear Office 124 High Street, Hampton Hill Middlesex, TW12 1NS, U.K. E-mail:

More information

16E1 + 1Ethernet Fiber Optical Multiplexer

16E1 + 1Ethernet Fiber Optical Multiplexer User s Manual To users: Thank you for using our products. Before using, please read this Reference Manual carefully, and keep properly. Alarm 1. This product cannot be caught in or be affected with damp,

More information

8 Chanel HD SDI Over Fiber. Transmitter and Reciever Extender. User Manual L-8SDI-FE-HD-TX/RX

8 Chanel HD SDI Over Fiber. Transmitter and Reciever Extender. User Manual L-8SDI-FE-HD-TX/RX 8 Chanel HD SDI Over Fiber Transmitter and Reciever Extender User Manual L-8SDI-FE-HD-TX/RX Contents CHAPTER 1. INTRODUCTION... 2 1.1 OVERVIEW...2 1.2 FEATURE...2 1.3 APPLICATION...3 CHAPTER 2. L-8SDI-FE-HD-TX/RX

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Agilent OBSAI Protocol Tester

Agilent OBSAI Protocol Tester Agilent OBSAI Protocol Tester Hardware Reference Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

OPCOM STM-1 High Capacity Terminal Multiplexer USER MANUAL. Raisecom Technology Co., Ltd (4/2005)

OPCOM STM-1 High Capacity Terminal Multiplexer USER MANUAL. Raisecom Technology Co., Ltd (4/2005) OPCOM3100-155 STM-1 High Capacity Terminal Multiplexer USER MANUAL Raisecom Technology Co., Ltd (4/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

T3 Interface Converters

T3 Interface Converters MT1103A JULY 2003 MT1103A-DC T3 Interface Converters CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day,

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

RC801-60B-FV35, RC803-60B-FV35, RC805-60B-FV35 Series Standalone V.35+E1 Dual Interface Fiber Optic Modem. User Manual REV.N

RC801-60B-FV35, RC803-60B-FV35, RC805-60B-FV35 Series Standalone V.35+E1 Dual Interface Fiber Optic Modem. User Manual REV.N RC801-60B-FV35, RC803-60B-FV35, RC805-60B-FV35 Series Standalone V.35+E1 Dual Interface Fiber Optic Modem User Manual REV.N Raisecom Technology Co., Ltd. (05/2006) 1. Cautions Please read the following

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual (Version 1.1) Beijing Fibridge Co., Ltd. Content 1. Overview... 3 2. Features... 4 2.1. Hardware... 4 2.2. Software... 5 3. Applications...

More information

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.1.S - 0 CMU 100 / 7.1.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.1.S - 0 User manual CMUMU11S

More information

FOMi-40 Fiber Optic Modem with Remote Management

FOMi-40 Fiber Optic Modem with Remote Management Data Sheet FOMi-40 Provides a secure and long-range data link of up to 100 km (62 mi) Selectable data rates from 56 to 2048 kbps Multimode or single mode operation Extended transmission range up to 100

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Loop-O 9300 Fiber Optical Mux

Loop-O 9300 Fiber Optical Mux 300 Fiber Optical Mux U height unit U height unit 3U height unit Features Up to 6 E links on one fiber Support Quad RS3 to 6Kbps async (Optional) Support Quad V.35 (Optional) Support 0/00M Bridge (Optional)

More information

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm 800xA Networks NE801 User Manual Power and productivity for a better worldtm 800xA Networks NE801 User Manual NOTICE This document contains information about one or more ABB products and may include a

More information

Copyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any CVT4K-S Fiber Converter Document Version: V1.0.1 Document Number: NS110100433 Copyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted

More information

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch 12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:

More information

Installation Manual. Table of Contents

Installation Manual. Table of Contents Table of Contents Table of Contents... 4-1 4.1 Confirming the Installation Preparations... 4-1 4.2 Installation Flowchart... 4-1 4.3 Mounting the Switch to the Designated Position... 4-2 4.3.1 Mounting

More information

Perle Gigabit Media Converter Module. Installation Guide P/N

Perle Gigabit Media Converter Module. Installation Guide P/N Perle Gigabit Media Converter Module Installation Guide Unmanaged Managed C-1000-M2SC05 C-1000-M2LC05 C-1000-S2LC10 C-1000-S2SC10 C-1000-S2LC40 C-1000-S2SC70 C-1000-S2LC70 C-1000-S1SC10U C-1000-S1SC10D

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

KOM600/KOM600G Fiber Media Converter Hardware Installation Manual

KOM600/KOM600G Fiber Media Converter Hardware Installation Manual KOM600/KOM600G Fiber Media Converter Hardware Installation Manual Kyland Technology Co., LTD. Publication Date: Dec. 2012 Version: V1.1 Customer Service Hotline: (+8610) 88796676 FAX: (+8610) 88796678

More information

RC552-FE (A) User Manual

RC552-FE (A) User Manual www.raisecom.com RC552-FE (A) User Manual May, 2006 Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties

More information

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

FSM-510G Series Ethernet Management Switch Quick Start Guide

FSM-510G Series Ethernet Management Switch Quick Start Guide FSM-510G Series Ethernet Management Switch Quick Start Guide Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easily

More information

Optimux-108, Optimux-106

Optimux-108, Optimux-106 Where to buy > Product page > Data Sheet Optimux-108, Multiplexer for 4E1/4T1 and Ethernet or Serial Data Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic link Various fiber

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

16-SLOT IN-BAND MANAGEMENT CHASSIS

16-SLOT IN-BAND MANAGEMENT CHASSIS FCM-CHS2-XX 16-SLOT IN-BAND MANAGEMENT CHASSIS User's Guide. Version 1.6 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed

More information

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high order legacy traffic (TDM) over SDH/SONET networks Any Traffic Over Fiber Multiplexes up to three E3 or T3 data channels using

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

Optimux-34 Fiber Optic Multiplexer

Optimux-34 Fiber Optic Multiplexer Data Sheet Optimux-34 Multiple E1, Ethernet, or High-speed Data over E3 or Fiber, up to 110 km (68 miles) Up to 16 E1 links, high-speed data, and Ethernet traffic multiplexed into one E3 copper or fiber

More information

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.6.S - 0 CMU 100 / 7.6.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.6.S - 0 User

More information

Industrial 3-Port Fast Ethernet Media Converter Switches

Industrial 3-Port Fast Ethernet Media Converter Switches Industrial 3-Port Fast Ethernet Media Converter Switches KSD-103-A series KSD-103-B series Installation Guide DOC.081111 1/20 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation

More information

Optimux-34, Optimux-25

Optimux-34, Optimux-25 Data Sheet Optimux-34, Optimux-25 16-Channel E1/T1, Ethernet or Data over E3 or Fiber Multiplexers Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber opt7ic uplink E3 copper

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

Loop-O9330 Fiber Optical Mux

Loop-O9330 Fiber Optical Mux Loop-O9330 Fiber Optical Mux Features Up to 16 E1 links and one 100Mbps ethernet link on one fiber Auto Laser Shutdown function is user configurable Supports 10/100M Ethernet Bridge plug-in card (Optional)

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

F /100Mbps Ethernet to 8E1 Converter. Standalone/Module/Chassis User Manual

F /100Mbps Ethernet to 8E1 Converter. Standalone/Module/Chassis User Manual F5-8513 10/100Mbps Ethernet to 8E1 Converter Standalone/Module/Chassis User Manual (Version: V1.5) Beijing Fibridge Co., Ltd. Content 1. General...2 2. Features...2 3. Specification:...2 3.1. E1 Port...2

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable. LGC010A-R2 LGC011A-R2 LGC012A-R2 LGC013A-R2 LGC014A-R2 LGC015A-R2 LGC016A-R2 LGC017A-R2 Gigabit Miniature Media Converters Connect Gigabit Ethernet copper ports to fiber optic cable. FCC and IC RFI Statements

More information

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011 An Expert in Optical Communications User Manual AN5506-01-A GPON Optical Network Unit Version: A Code: MN000000943 Date: December 2011 FiberHome Telecommunication Technologies Co., Ltd. Version Version

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

F9-480 Series 4/8/16E1 Plus Ethernet Multi-service Multiplexer User Manual

F9-480 Series 4/8/16E1 Plus Ethernet Multi-service Multiplexer User Manual F9-480 Series 4/8/16E1 Plus Ethernet Multi-service Multiplexer User Manual (Version 2.1) Beijing Fibridge Co., Ltd Table of Content 1. Overview...3 2. Features...3 2.1. Hardware Features...3 2.2. Software

More information

4 E1-4 x 10/100 Ethernet converter with VLAN

4 E1-4 x 10/100 Ethernet converter with VLAN 4 E1-4 x 10/100 Ethernet converter with VLAN dot1q support and professional GUI NMS Spot-light: 4 E1-4 x 10/100 Ethernet converter with GFP-F, VC (Virtual Concatenation), LCAS support and professional

More information

Industrial Ethernet Switch

Industrial Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the hardened Ethernet Switch. Capable of operating at temperature extremes of -10 C to +60 C, this is the switch of choice for

More information

Fiber optic converter audio and CAN TA OPERATION MANUAL

Fiber optic converter audio and CAN TA OPERATION MANUAL Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.

More information

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-022 2017A-0330 4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System SYSTEM INSTALLATION INFORMATION Description The 4 Channel

More information

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP TELECOMMUNICATION INTERNATIONAL, INC. 8F, NO. 8, HSIN ANN

More information

Media Converters. Media Converters. Product Selection Guides

Media Converters. Media Converters. Product Selection Guides Product Selection Guides Media Converters Serial-to-Fiber Converter Selection Guide....................................-2 Serial-to-Serial Converter Selection Guide...................................-3

More information

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual KIEN2204S Industrial Ethernet Switch Hardware Installation Manual Kyland Technology Co., Ltd. Publication Date: Mar. 2013 Version: V1.0 FAX: +86-10-88796678 Website: http://www.kyland.com E-mail: support@kyland.com

More information

IMC-21 Quick Installation Guide

IMC-21 Quick Installation Guide IMC-21 Quick Installation Guide Moxa Industrial Media Converter Edition 5.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

FB-10/100MMC Series Managed/Unmanaged. 10/100Mbps Fiber Media Converter User Manual

FB-10/100MMC Series Managed/Unmanaged. 10/100Mbps Fiber Media Converter User Manual FB-10/100MMC Series Managed/Unmanaged 10/100Mbps Fiber Media Converter User Manual (Version 1.5) Beijing Fibridge Co., Ltd. Content 1. Overview... 3 2. Features... 3 2.1. Hardware Features... 3 2.2. Software

More information

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel VCL-TP, Teleprotection Equipment With Trip Counter Display Panel Data Sheet Copyright: Valiant Communications Limited. 2008-2014 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable

More information

Preparing to Install the Cisco AS5350XM Universal Gateway

Preparing to Install the Cisco AS5350XM Universal Gateway CHAPTER 2 Preparing to Install the Cisco AS5350XM Universal Gateway This chapter describes the tasks you must perform before you begin to install the Cisco AS5350XM universal gateway and includes the following

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

Gigabit Ethernet Media Converter. User Manual

Gigabit Ethernet Media Converter. User Manual Gigabit Ethernet Media Converter User Manual (Version 1.2) Beijing Fibridge Co., Ltd. Contents 1. Overview... 3 2. Features... 3 3. Application... 5 4. Specification... 5 4.1. Ethernet Port... 5 4.2. Fiber

More information

PTC-101 Quick Installation Guide

PTC-101 Quick Installation Guide PTC-101 Quick Installation Guide Moxa Industrial Media Converter Edition 5.1, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

RS-422/485 to Fiber Industrial Converter

RS-422/485 to Fiber Industrial Converter RS-422/485 to Fiber Industrial Converter (IRF-612) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

Bridge Module. Installation Guide and Users Reference Manual

Bridge Module. Installation Guide and Users Reference Manual Bridge Module Installation Guide and Users Reference Manual This manual contains information to help with the installation and operation of Black Box Corporation's Bridge Modules and 100-Mbps Modules.

More information

IMC-21GA Quick Installation Guide

IMC-21GA Quick Installation Guide IMC-21GA Quick Installation Guide Moxa Industrial Media Converter Edition 4.0, June 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM Document No. 101052 Rev. 01 PAGE 2 INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF

More information

Rugged MediaConverter

Rugged MediaConverter Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006

More information

Preface. Media Converter

Preface. Media Converter Preface This manual describes how to install and use the Ethernet Media Converter with the link-fault-pass-through function. The Converter introduced here provides one channel media conversion between

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide First Edition, February 2012 2012 Moxa Inc. All rights reserved. P/N: 1802001016020 Overview Moxa Industrial Media Converter, which

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information