RC954 Series Modular Inverse Multiplexer User Manual

Size: px
Start display at page:

Download "RC954 Series Modular Inverse Multiplexer User Manual"

Transcription

1 RC954 Series Modular Inverse Multiplexer User Manual

2 Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Raisecom Technology Co., Ltd shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Warranty. A copy of the specific warranty terms applicable to your Raisecom product and replacement parts can be obtained from Service Office. Restricted Rights Legend. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Raisecom Technology Co., Ltd. The information contained in this document is subject to change without notice. Copyright Notices. Copyright 2007 Raisecom. All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in Writing from Raisecom Technology Co., Ltd. Trademark Notices is the trademark of Raisecom Technology Co., Ltd. Java is a U.S. trademark of Sun Microsystems, Inc. Microsoft is a U.S. registered trademark of Microsoft Corporation. Windows NT is a U.S. registered trademark of Microsoft Corporation. Windows 2000 is a U.S. registered trademark of Microsoft Corporation. Windows XP is a U.S. registered trademark of Microsoft Corporation. Windows and MS Windows are U.S. registered trademarks of Microsoft Corporation.

3 Contact Information Technical Assistance Center The Raisecom TAC is available to all customers who need technical assistance with a Raisecom product, technology, or, solution. You can communicate with us through the following methods: Address: 2 nd Floor, South Building of Rainbow Plaza, No.11 Shangdi Information Road, Haidian District, Beijing Tel: Fax: World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL: Feedback Comments and questions about how the RC954 series devices work are welcomed. Please review the FAQ in the related manual, and if your question is not covered, send by using the following web page: If you have comments on the specification of RC954 series devices, instead of the web page above, please send comments to: export@raisecom.com We hope to hear from you!

4 CONTENTS General Safety Instructions Chapter 1 Overview Main features Device naming rules Device exterior and size Chapter 2 Technical Parameters Product basic configuration Ethernet interface property Electrical interface Optical interface E1 interface property Power supply Operating environment Chapter 3 Structure and Indicator Definition Structure and indicator definition Dip switch instruction Chapter 4 Application mode Chapter 5 Installation and Testing Cautions Installation process Setup dip switch Connect service Ethernet interface Connect E1 cable Electrify Configure services Cable preparation Chapter 6 Troubleshooting Appendix A DB37 Connector E1 Cable Pin Definition Appendix B RJ45 Connector E1 Cable Pin Definition Appendix C Specialized Vocabulary and Acronyms

5 Preface Who Should Read This Manual This document is for professionals who have the knowledge of configuring RC954 series devices. It introduces the principle and properties of function modules of RC954 series devices systematically. It is also a configuration guide of the modules. Relevant Manuals RC954-FE(FX)4E1 User Manual Organization The core content of this user manual is composed of six chapters: Chapter 1 Overview Chapter 2 Technical parameters Chapter 3 Structure and indicator definition Chapter 4 Application mode Chapter 5 Installation and testing Chapter 6 Troubleshooting Compliance The RC series products developed by Raisecom are strictly complied with the following standards as well as ITU-T, IEEE, IETF and related standards from other international telecommunication standard organizations: YD/T SDH Equipment Technical Requirements - Clock YD/T SDH 155Mb/s and 622Mb/s Technical conditions of optical transmitter module and receiver module YD/T Network node interface for the Synchronous Digital Hierarchy (SDH) YD/T Requirement of synchronous digital hierarchy (SDH) equipment function YD/T SDH Transmission Network Technique Requirements-Interworking of Network Protection Architectures YD/T Technical Requirements of SDH Optical Transmitter/Optical Receiver Modules Gb/s Optical Receiver Modules YD/T Technical Requirements of SHD Optical Transmitter/Optical Receiver Modules Gb/s Optical Transmitter Modules 5

6 YD/T Technical Specification of Ethernet over SDH G.703 Physical/electrical characteristics of hierarchical digital interfaces G.704 Synchronous frame structures used at 1544, 6312, 2048, 8448 and kbit/s hierarchical levels G.707 Network node interface for the synchronous digital hierarchy (SDH) G.774 Synchronous digital hierarchy (SDH) - Management information model for the network element view G.781 Synchronization layer functions G.783 Characteristics of synchronous digital hierarchy (SDH) equipment functional blocks G.784 Synchronous digital hierarchy (SDH) management G.803 Architecture of transport networks based on the synchronous digital hierarchy (SDH) G.813 Timing characteristics of SDH equipment slave clocks (SEC) G.823 The control of jitter and wander within digital networks which are based on the 2048 kbit/s hierarchy G.825 The control of jitter and wander within digital networks which are based on the synchronous digital hierarchy (SDH) G.826 End-to-end error performance parameters and objectives for international, constant bit-rate digital paths and connections G.828 Error performance parameters and objectives for international, constant bit-rate synchronous digital paths G.829 Error performance events for SDH multiplex and regenerator sections G.831 Management capabilities of transport networks based on the synchronous digital hierarchy (SDH) G.841 Types and characteristics of SDH network protection architectures G.842 Interworking of SDH network protection architectures G.957 Optical interfaces for equipments and systems relating to the synchronous digital hierarchy G.691 Optical interfaces for single channel STM-64 and other SDH systems with optical amplifiers G.664 Optical safety procedures and requirements for optical transport systems I.731 ATM Types and general characteristics of ATM equipment I.732 ATM Functional characteristics of ATM equipment IEEE 802.1Q Virtual Local Area Networks (LANs) IEEE 802.1p Traffic Class Expediting and Dynamic Multicast Filtering IEEE CSMA/CD Access Method and Physical Layer Instruction 6

7 General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel. Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines. Protective earth: the marked lug or terminal should be connected to the building protective earth bus. Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached. Please observe the following precautions: Before turning on the chassis with optic module, make sure that the fiber optic cable is intact and is connected to the transmitter. Do not attempt to adjust the laser drive current. Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam. The use of optical devices with the equipment will increase eye hazard. Use of controls, adjustments or performing procedures other than those specified herein, may result in hazardous radiation exposure. ATTENTION: The laser beam may be invisible! Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user. All extension slots are not hot-swappable Before operating modules in the electricity conditions, please be noticed that optical modules shall be connected with optical fiber wires or shield with optical module cover for fear that laser light harms to operator s eyes. Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is 7

8 blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist. Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts. Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is provided on the product, it should be connected to the protective earth at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and cabinets. Always make the ground connection first and disconnect it last. Do not connect telecommunication cables to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the ground. Connection of AC Mains Make sure that the electrical installation complies with local codes. Always connect the AC plug to a wall socket with a protective ground. Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation. Connection of DC Mains Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded. Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards. DC units should be installed in a restricted access area, i.e. an area where access is authorized only to qualified service and maintenance personnel. Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes. Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation. Preventing Electrostatic Discharge Damage Modules which can be plugged into chassis are sensitive to damage from static electricity. Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper electrostatic discharge (ESD) precautions can result in intermittent or complete component failures. To minimize the potential for ESD damage, observe the following guidelines: Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good skin contact. When removing or installing a component, make sure the equipment end of your antistatic strap leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal surface on the chassis. Avoid contact between the component and your clothing. The wrist strap only protects the component from ESD voltages on the body; ESD voltages on your clothing can still cause component damage. Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a static shielding bag. If you are returning the item to the factory, immediately place it in a static shielding bag. Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector pins. 8

9 Chapter 1 Overview RC954 series products are E1 protocol converters with inverse multiplexer function. They are designed to be applied to RC002 chassis of Raisecom. RC954 series products are equipped with 1 or 2 user Ethernet interfaces and 4 or 8 E1 interfaces. They are mainly used to transmit or receive Ethernet operations with band width range from 2Mbps to 16Mbps. At this stage, RC954 series products include RC954-FE/FX4E1, RC954-FE/FX4E1-BL, RC954-2FE4E1-BL and RC954-2FE8E1-BL. Ethernet interface can be chosen from electrical interface and optical interface. RC954-FE/FX4E1-BL occupies one slot and can be plug into RC002 series single-slot or multi-slot chassis. RC954-FE/FX4E1, RC954-2FE4E1-BL or RC954-2FE8E1-BL occupies two slots and can be plug into RC002 series dual-slot or multi-slot chassis. 1.1 Main features 1.2 Device naming rules 4 or 8 E1 interfaces 1 or 2 Ethernet interfaces Electrical interface: AUTO-NEGOTIATION, AUTO-MIDX, 10M/100M, Full/Half Duplex, 802.3x supported under full-duplex mode, back-pressure flow control supported under half-duplex mode. Optical interface: 100FX E1 inverse multiplexer mode: Transmit Ethernet frame to multiplex E1 using inter-frame interpolation. Auto-recognition of E1 link pin arrangement Maximal relative time delay of E1 link is +/-16ms Automatic setup and removal of E1links. Only framed mode is supported by E1 port; FAS+CRC4 PCM31 format is adopted; user-configurable CRC self-adaptation. HDLC frame format encapsulation for Ethernet data E1 loop-back testing Error detector supported Rich E1 circuit information displaying on the panel E1 interface type: balanced and unbalanced. Users can select a type using dip switch or by selecting different modules. All-around network management supported Card device for RC002 single-slot or multi-slot chassis Power consumption < 5W, stable and reliable operating. Operating temperature: -5~50 All devices are composed of circuit board and power supply board. RC954 series devices naming rule: RC954 A B C Explanation: RC954: E1 protocol converters with inverse multiplexer function which are designed for RC002 series chassis. A: FE type and the number of E1 interface, could be FE4E1, FX4E1, 2FE4E1, 2FE8E1 FE4E1: Electrical FE interface, 4E1 9

10 FX4E1: Optical FE interface, 4E1 2FE4E1: 1 electrical FE interface and 1 optical FE interface, 4 E1 2FE8E1: 1 electrical FE interface and 1 optical FE interface, 8 E1 B: E1 interface type. BL indicates that the interface is a balanced interface. No specification of this term indicates that the interface is unbalanced or the type can be selected using dip switch. C: Ethernet optical interface type. Only applicable to Ethernet optical interface, could be M, S1, S2, S3, SS13, SS15, SS23, SS25, S15, and etc. Type Wavelength Distance M Multi Mode, 1310nm [1] 0-2km S1 Single Mode, 1310nm 0-25km S2 Single Mode, 1310nm 10-60km S3 Single Mode, 1550nm km SS13 Single Mode, Transmit, 1310nm Single Mode, Receive, 1550nm 0-25km SS15 Single Mode, Transmit, 1550nm Single Mode, Receive, 1310nm 0-25km SS23 Single Mode, Transmit, 1310nm Single Mode, Receive, 1550nm 10-50km SS25 Single Mode, Transmit, 1550nm Single Mode, Receive, 1310nm 10-50km S15 Single Mode, 1550nm 0-25km [1] For multi mode optical emitter, both wavelength 850nm and 1310nm are available. The default wavelength is 1310nm. 850nm multi mode optical emitter will only be made to order. For detailed available product list, please refer to product ordering information. 1.3 Device exterior and size RC954-FE/FX4E1-BL: occupies one slot, 25.2nm(Width) 91mm(Height) 172mm(Depth) RC954-FE/FX4E1, RC954-2FE4E1-BL, RC954-2FE8E1-BL: occupies two slots (one for master card, the other for E1 interface sub card), 50.5nm(Width) 91mm(Height) 172mm(Depth) 10

11 Chapter 2 Technical Parameters 2.1 Product basic configuration Master card: a FE electrical interface or a FE optical interface or an integral electro-optical interface; a chassis backboard interface Sub card: 4 or 8 E1 interfaces 2.2 Ethernet interface property Electrical interface Optical interface Rate: 10/100M self-adaptation Interface: RJ-45 Compliant to IEEE x flow control Pin arrangement as host mode; AUTO-MIDX supported Rate: 100M Interface: SC 2.3 E1 interface property 4 or 8 E1 interface; can be configured to single channel mode or inverse multiplexer mode E1 inverse multiplexer mode: Transmit Ethernet frame to multiplex E1 using inter-frame interpolation. Auto-recognition of E1 link pin arrangement Maximal relative time delay of E1 link is +/-16ms Automatic setup and removal of E1links. Only framed mode is supported by E1 port; FAS+CRC4 PCM31 format; user-configurable CRC self-adaptation. HDLC frame format encapsulation for Ethernet data E1 loop-back testing Error detector supported 512K Bytes buffer for every channel in the direction from Ethernet to E1 Bit rate: 2048Kbps±50ppm Code pattern: HDB3 Input impedance: 75Ω unbalanced or 120Ω balanced; can be selected using dip switch Interface: DB37 male connector or RJ-45 balanced interface Electrical characteristics: compliant to ITU-T G 703 Frame structure: compliant to ITU-T G704 Jitter: compliant to ITU-T G823 1 or 2 panel indicator for every E1 link (different definition for different device, please check silk printing on the panel and correspond it to the instructions below) LAR: Local total alarms, includes LOS (Loss of Signal), AIS (Alarm Indication Signal), LOF (Loss of Frame), CRC (Cyclic Redundancy Check). RAL: Remote total alarms, includes LOS, AIS, LOF, CRC LOS: Local LOS alarm, loss of local signal Dip switch on the master card realizes the following control operation: Master/Slave management setting Enable/Disable loop-back control Remote/Local loop back selection Error detector setting 11

12 2.4 Power supply Configuration of self-adaptation/rate/full-duplex function for Ethernet electrical interface Clock selection Accept local management through backboard communication; execute in-band management on remote side through E1 Voltage of power supply: DC 5V, allowance range from 4.5V to 5.5V Power consumption: <5W 2.5 Operating environment Temperature: -5 ~50 Relative humidity: 90%(35 ) 12

13 Chapter 3 Structure and Indicator Definition 3.1 Structure and indicator definition Figure 5-1 RC954-FE4E1 Structure Figure 5-2 RC954-FX4E1 Structure Table 5-1 is an instruction of the panel of RC954-FE/FX4E1. Table 5-1 RC954-FX4E1 panel instructions Serial number Title Color of indicator Description 1 PWR indicator Green The nether indicator on the left of Ethernet electrical interface Power supply indicator PWR 13

14 2 Ethernet electrical interface 3 Ethernet optical interface Green Green On: the power supply is working normally Only applicable to Ethernet electrical interface. RJ-45 interface; 3 indicator LNK/ACT: The upper indicator on the left of Ethernet electrical interface On: link has been connected successfully Flickering: data transmitting or receiving Off: Link has not been set up 100M: The upper indicator on the right of Ethernet electrical interface On: Link is working at 100M Off: Link is working at 10M FDX: The nether indicator on the right of Ethernet electrical interface On: Link is working in full-duplex mode Off: Link is working in half-duplex mode Only applicable to Ethernet optical interface. SD interface; 2 indicator LNK/ACT: The upper indicator on the right of Ethernet optical interface On: link has been connected successfully Flickering: data transmitting or receiving Off: Link has not been set up SD: The nether indicator on the right of Ethernet optical interface On: optical signal has been detected Off: optical signal has not been detected 4 E1 interface - E1 interface is a DB37 male connector Special cable should be applied to convert DB37 male connector to DNC or RJ-45 connector. 5 E1 indicator Red or Yellow For every E1, there is an L indicator and an R indicator. L: Local total alarms Red On: LOS alarm 14

15 Red Flickering: AIS alarm Yellow On: LOF alarm Yellow Flickering: CRC alarm OFF: No alarm R: remote total alarm Red On: LOS alarm Red Flickering: AIS alarm Yellow On: LOF alarm Yellow Flickering: CRC alarm Off: No alarm In addition: Both L and R indicators are turned on indicates GID alarm Figure 5-3 RC954-FE4E1-BL structure Table 5-2 is an instruction of the panel of RC954-FE/FX4E1. Table 5-2 RC954-FE/FX4E1 panel instructions Serial number Title Color of indicator Description 1 A, B, C, D four E1 line indicators Three colors A, B, C, D four E1 line indicator Every E1 has a local total alarm indicator E1 LAL: Red On: LOS alarm Red Flickering: AIS alarm Yellow On: LOF alarm Yellow Flickering: CRC alarm OFF: No alarm 15

16 2 A, B, C, D four E1 balanced interface 3 Ethernet electrical interface indicator 4 Ethernet electrical interface - Green - Provide four lines of E1, 120Ω balanced signal by the combination of 2 RJ-45 sockets A, B common RJ-45 interface A: core 1 and 2 output core 4 and 5 input B: core 3 and 6 input core 7and 8 output C, D common RJ-45 interface C: core 1and 2 output core 4 and 5 input D: core 3and 6 input core 7 and 8 output Before making balanced cable, please read pin arrangement instruction with caution to ensure correct pin arrangement. LNK/ACT: the left indicator on the top of Ethernet electrical interface On: link has been connected successfully Off: Link has not been connected Flickering: data transmitting or receiving 100M: the right indicator on the top of Ethernet electrical interface On: link is working at 100M Off: link is working at 10M FDX: the upper indicator on the right of Ethernet electrical interface On: Link is working in full-duplex mode Off: link is working in half-duplex mode RJ-45 interface; 3 indicators 5 PWR Green Power supply indicator PWR: the nether indicator on the right of Ethernet electrical interface On: the power supply is working properly 16

17 Figure 5-4 RC954-FX4E1-BL structure Table 5-3 is an instruction of the panel of RC954-FX4E1-BL. Table 5-3 RC954-FX4E1-BL panel instructions Serial number Title Color of indicator Description 1 PWR Green Power supply indicator PWR On: the power supply is working properly 2 E1 indicator Red On the top of the four E1 interface Red On: LOS occurs on E1 3 4 E1 interface - RJ-45 interface Red Off: E1 is working properly 2 RJ-45 interfaces make up of 4 E1 interfaces Every RJ-45 interface comprises 2 E1 4 Ethernet optical interface - 100M FX SC interface TX: optical signal output RX: optical signal input 5 Ethernet optical interface indicator Green SC interface, 2 indicators LNK/ACT: the upper indicator on the right of Ethernet optical interface On: link has been connected successfully Flickering: data transmitting or receiving Off: Link has not been connected SD: the nether indicator on the right of 17

18 Ethernet optical interface On: optical signal has been detected Off: optical signal has not been detected Figure 5-5 RC954-2FE4E1-BL Structure Figure 5-6 RC954-2FE8E1-BL structure Table 5-4 is an instruction of the panel of RC954-2FE4E1-BL and RC954-2FE8E1-BL Table 5-4 RC954-2FE4E1-BL and RC954-2FE8E1-BL panel instructions Serial number Title Color of indicator Description 1 PWR Green Power supply indicator PWR On: the power supply is working properly 2 Ethernet optical interface Green SC interface, 1 indicator LNK/ACT: the upper indicator on the left of Ethernet optical interface 18

19 3 E1 interface - RJ-45 interface On: Link has been connected successfully Flickering: data transmitting or receiving Off: link has not been connected RC954-2FE4E1-BL: 2 RJ-45 interfaces make up of 4 E1 interfaces Every RJ-45 interface comprises 2 E1 RC954-2FE8E1-BL: 4 RJ-45 interfaces make up of 8 E1 interfaces Every RJ-45 interface comprises 2 E1 4 Ethernet electrical interface 5 Ethernet electrical interface indicator - Green RJ-45 interface, 2 indicators RJ-45 interface, 2 indicators LNK/ACT: the left indicator on the top of Ethernet electrical interface On: link has been connected successfully Off: link has not been connected Flickering: data transmitting or receiving 100M: the right indicator on the top of Ethernet electrical interface On: link is working at 100M Off: link is working at 10M 6 E1 indicator Red LOS indicator: Red On: LOS alarm Red Off: normal 3.2 Dip switch instruction On the motherboard of RC954-FE/FX4E1, a dip switch SW3 is available to control the operation mode of the device (can be adjusted to user need). 19

20 Switch serial number Switch digit Serial number Definition Title Function ON OFF SW3 1 MMD Management mode setting Master device Slave device 2 LPEN Loop-back enabling setting Enable back loop Disable back loop 3 LPMD Loop-back mode setting Local loop back when loop back is enabled Remote loop back when loop back is enabled 4 BERT Error detector function setting Turn on E1 error testing function Turn off E1 error testing function 5 AN Ethernet electrical interface auto-negotiation setting Disable Ethernet self-adaptation Enable Ethernet self-adaptation 6 SPD Ethernet electrical interface setting rate Force Ethernet to work at 10Mbps when self-adaptation is forbidden. Force Ethernet to work at 100Mbps when self-adaptation is forbidden. 7 DPX Ethernet electrical interface duplex setting Force Ethernet to work under half-duplex mode when self-adaptation is disabled Force Ethernet to work under full-duplex mode when self-adaptation is disabled 8 TMD E1 clock mode setting Slave clock Master clock On the motherboard of other RC954 series devices (exclude RC954-FE/FX4E1), a dip switch SW3 is available to control the operation mode of the device (can be adjusted to user need). Switch serial number Switch digit Serial number Definition Title Function ON OFF 20

21 SW3 1 MMD Management mode setting Force to slave device Self-adapta tion 2 LPEN Loop-back enabling setting Enable back loop Disable loop back 3 LPMD Loop-back mode setting Local loop back when loop back is enabled Remote loop back when loop back is enabled 4 BERT Error detector function setting Turn on E1 error testing function Turn off E1 error testing function 5 AN Ethernet electrical interface auto-negotiation setting Disable Ethernet self-adaptation Enable Ethernet self-adaptat ion 6 SPD Ethernet electrical interface setting rate Force Ethernet to work at 10Mbps when self-adaptation is forbidden. Force Ethernet to work at 100Mbps when self-adaptat ion is forbidden. 7 DPX Ethernet electrical interface duplex setting Force Ethernet to work under half-duplex mode when self-adaptation is disabled Force Ethernet to work under full-duplex mode when self-adaptat ion is disabled 8 TMD E1 clock mode setting Slave clock Master clock On the motherboard of RC954 series devices, a SW4 dip switch is available to start up E1 links. (can be adjusted to user need) 21

22 Switch serial number Switch digit serial number Definition ON OFF SW4 1 Do not start up the first E1 2 Do not start up the second E1 3 Do not start up the third E1 4 Do not start up the fourth E1 Start up the first E1 Start up the second E1 Start up the third E1 Start up the fourth E1 RC954-2FE8E1-BL has 8 SW4 dip switch digits; they correspond to the startup of the fifth, sixth, seventh and eighth E1. For devices with Ethernet optical interface, a SW1 dip switch is available on the motherboard to inform the optical interface type to the software. (Please keep SW1 factory setting. User modification is not recommended.) Switch serial number Switch digit serial number Optical emitter type SW1 ON ON ON ON M ON ON ON OFF S1 ON ON OFF ON S2 ON ON OFF OFF S3 ON OFF ON ON SS13 ON OFF ON OFF SS15 ON OFF OFF ON SS23 ON OFF OFF OFF SS25 OFF x x x Reserved On the motherboard of RC954-2FE8E1-Bl, there is a special function dip switch SW1 (Other RC954 series devices do not have this dip switch). Its function is shown is the following table: 22

23 Switch serial number Switch digit Serial number Definition Title Function ON OFF SW1 1 UPD Program renewal setting On-line upgrade mode Normal working mode 2 ALS Optical interface ALS (Automatic Laser Shutdown) enabling setting Enable optical interface ALS function Disabler optical interface ALS function On the face of RC954-FE/FX4E1 sub card, a 4 digit dip switch is available for every E1 to select from balanced mode and unbalanced mode. (SW1 corresponds to the first E1; SW2 corresponds to the second E1; SW3 correspond to the third E1; SW4 correspond to the fourth E1) Switch serial number Switch digit serial number Optical emitter type SW1/2/3/4 ON ON ON OFF Unbalanced OFF OFF OFF ON Balanced Others Forbidden 23

24 Chapter 4 Application mode As is shown in the figure above, place a RC953-FE4E1 at the access node of user branch, place a RC954-FE4E1 at user center, and transmit service from each branch access node to user center, a service channel with capability of 2M~8M will be established between user center and each branch access node. As is shown in the figure above, place RC5/6 series media converter at the access node of user branch, place RC954-FX4E1 at user access node in the carrier s computer room, place RC954-FX4E1 at user centre, and transmit services from each branch access node to user center, a service channel with capability of 2M~8M will be established between user center and each branch access node. 24

25 Chapter 5 Installation and Testing 5.1 Cautions Firstly, please check the model and the number of the device and spare parts according to the packing list. Please be sure that the appearance of the device is intact. If there is any evidence that the device has been affected by damp, please dry it before installation. To insure that the device can operate properly, please install and setup the device follow the steps listed below: Read this manual with caution. Fix and install the device Connect Ethernet cable, fiber and E1 cable. Electrify and configure the device. Please refer to network management user manual for steps for configuration. Operate properly 5.2 Installation process Setup dip switch Setup dip switch according to user need and the definition of dip switch in chapter 3. Plug the device into RC002 chassis. Note: The setting of Master/Slave management mode and E1 channel startup will be obedient to the status of the corresponding dip switch when the device is being electrified. Any operation to these two dip switches is invalid afterward. Other dip switches are valid for operating after electrifying Connect service Ethernet interface Connect E1 cable Electrify For device with Ethernet electrical interface, connect one end of the Ethernet cable to the Ethernet interface of this device, and connect the other end of the Ethernet cable to router or Ethernet switch. For device with Ethernet optical interface, connect one end of the fiber to the Ethernet optical interface, and connect the other end of the fiber to router or Ethernet switch. For device with unbalanced E1 interface, use the DB37 connector on E1 cable to connect to E1 interface on local device, and use BNC connector to connect to transmission devices or congener devices. For device with balanced E1 interface, apply cable with two RJ-45 connectors and two E1 link to connect. After turn on the power, the PWR indicator should be on. At the same time, please check the Ethernet interface indicator and E1 interface indicator, they should be working in order. (For the meanings of the indicators, please refer to the indicator definition in chapter 3) Configure services If RC954 is used as master management device, user PC can be connected to the management module in RC002 chassis to manage RC954 and remote devices. For detailed configuration operation, please refer to 25

26 relevant command line notebook and network management manual. 5.3 Cable preparation Table 7-1 Connecting cable specification for RC954 device interface Interface 10/100Mbps Ethernet electrical interface Cable specification One Only for devices with Ethernet electrical interface 100Base-T CAT-5 UTP (User self-prepare) Fiber with SC connector Two Only for devices with Ethernet optical interface Single/Multiple mode, correspond to devices (User self-prepare) DB37 BNC Cable (75Ω unbalanced) One Only for unbalanced E1 interface (Additional item) DB37 RJ45 Cable (120Ω balanced) One Only for balanced E1 interface (Additional item) RJ-45 E1 Cable Two or Four Only for RC954-XXXX-BL series devices (User self-prepare) 26

27 Chapter 6 Troubleshooting For some problems you may meet during installation and operation, please try to solve them following the suggestions below. For the problems can not be solved using the following suggestions, please contact with distributors for technical support. PWR indicator wouldn t turn on after power supply has been connected. Firstly, please check whether the device has been plugged in properly. Then, please make sure that power supply of the chassis is working properly. LOS alarm occurs at E1 interface LOS alarm indicates lost of receiving signals Firstly, please check whether the E1 cable has been connected properly. If alarm occurs when the E1 cable has been connected correctly, please replace the cable and check whether the device on the other side is operating properly. Ethernet interface LINK indicator wouldn t turn on Firstly, please check whether the cable is broken down. Secondly, please check whether the network device connected to the Ethernet interface is working properly. Please make sure that the cable is correctly made. 27

28 Appendix A DB37 Connector E1 Cable Pin Definition E1 interface for RC954 devices applies DB37 connector. DB37 female connector is provided in standard accessory list. Users can make cable by complying with the following pin definition. Pin Definition Pin Definition OUT1-21 IN1+ 4 OUT1+ 22 IN OUT2-25 IN2+ 8 OUT2+ 26 IN OUT3-29 IN3+ 12 OUT3+ 30 IN OUT4-33 IN4+ 16 OUT4+ 34 IN Note: For unbalanced cable, + for signal, - for shielded layer 28

29 Appendix B RJ45 Connector E1 Cable Pin Definition Using E1 balanced data cable Pin 1 Pin 8 For E1 120Ω balanced interface, pin definition is shown in the table below: RJ-45 Pin definition with A, B channel identifier Pin Data ATD+ ATD- BRD+ ARD+ ARD- BRD- BTD+ BTD- Definition Channel A Channel A Channel B Channel A Channel A Channel B Channel B Channel B Output + Output - Input + Input + Input - Input - Output + Output - Using 120Ω balanced interface to connect to other device, please be clear of the pin definition of the device. For twisted pair, the connecting rule of pins on the two ends is shown in the figure below: Please note that when connecting twisted pairs, please connect the two from TD+ and TD- that are twisted together. The same rule applies to RD+ and RD-. 29

30 Appendix C Specialized Vocabulary and Acronyms EoPDH Ethernet over PDH:Bear Ethernet data services over PDH. Mainly indicates bearing Ethernet service over E1 in this document. PDH FAS LOS LOF AIS CRC LAL RAL SD GID Pseudo-synchronous Digital Hierarchy Frame Alignment Signaling Loss of Signal Loss of Frame Alarm Indication Signal Cyclic Redundancy Check Local Alarm: Mainly indicates reverse alarms received on E1 excluding LOS alarm in this document. Include AIS, LOF, and CRC alarm. Remote Alarm: Mainly indicates LOS, AIS, LOF, and CRC alarms from remote devices in this manual. Signal Detect: Indicates whether light has been detected by the receiving part of optical module or not in this manual. Group Identification: E1 belonged to one inverse multiplexer group should share one ID. Different group uses different ID. 30

31 Address: 2 nd Floor, South Building of Rainbow Plaza, No.11 Shangdi Information Road, Haidian District, Beijing Postcode: Tel: Fax: export@raisecom.com 31

RC952-FEDS3/E3 Modular DS3/E3 Interface Converter User Manual

RC952-FEDS3/E3 Modular DS3/E3 Interface Converter User Manual RC952-FEDS3/E3 Modular DS3/E3 Interface Converter Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties

More information

RC832-30(-BL) User Manual

RC832-30(-BL) User Manual RC832-30(-BL) Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for

More information

RC E User Manual

RC E User Manual RC831-240E Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for

More information

RC702-FX Ethernet over SDH User Manual

RC702-FX Ethernet over SDH User Manual RC702-FX Ethernet over SDH User Manual Raisecom Technology Co., Ltd 1. Caution Please carefully read the following precautions before installing and deploying RC702-FX equipment, and operate strictly according

More information

RC552-FE (A) User Manual

RC552-FE (A) User Manual www.raisecom.com RC552-FE (A) User Manual May, 2006 Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties

More information

RCMS Modular Optical Multiplexer Manual

RCMS Modular Optical Multiplexer Manual RCMS2404-240 Modular Optical Multiplexer Manual Beijing Raisecom science & technology Co. Ltd Content Chapter 1 Overview... 1 Chapter 2 Technical characteristic... 2 Chapter 3 Instruction... 3 Chapter

More information

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd. Multi-Service Access Platform OPCOM3500E-12 OPCOM3500E-12 Feature Overview OPCOM3500E MSAP is carrier-class Multi-Service Access Platform, and designed to enable establishment of service-integrated for

More information

RC905-EE1. Ethernet to E1 Interface Converter (REV.B) User Manual

RC905-EE1. Ethernet to E1 Interface Converter (REV.B) User Manual RC905-EE1 Ethernet to E1 Interface Converter (REV.B) User Manual 1 Contents Chapter 1 RC905-EE1(REV. B) Overview... 3 Chapter 2 Operating Instruction..... 4 Chapter 3 Connection..... 11 Chapter 4 Troubleshooting..

More information

RC701/RC702-FE series Ethernet over SDH devices User Manual

RC701/RC702-FE series Ethernet over SDH devices User Manual RC701/RC702-FE series Ethernet over SDH devices User Manual Raisecom Technology Co., Ltd 1. Cautions Warning: Only trained and qualified personnel should be allowed to install, replace or service this

More information

OPCOM STM-1 High Capacity Terminal Multiplexer USER MANUAL. Raisecom Technology Co., Ltd (4/2005)

OPCOM STM-1 High Capacity Terminal Multiplexer USER MANUAL. Raisecom Technology Co., Ltd (4/2005) OPCOM3100-155 STM-1 High Capacity Terminal Multiplexer USER MANUAL Raisecom Technology Co., Ltd (4/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO F8016 Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO Description The fiber transmission platform is a fiber optic multiplexer with a fully new designing concept to challenge

More information

T3 Interface Converters

T3 Interface Converters MT1103A JULY 2003 MT1103A-DC T3 Interface Converters CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day,

More information

RC3000E Commands Notebook

RC3000E Commands Notebook RC3000E Notebook Legal Notices Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness

More information

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual (Version 1.1) Beijing Fibridge Co., Ltd. Content 1. Overview... 3 2. Features... 4 2.1. Hardware... 4 2.2. Software... 5 3. Applications...

More information

16E1 + 1Ethernet Fiber Optical Multiplexer

16E1 + 1Ethernet Fiber Optical Multiplexer User s Manual To users: Thank you for using our products. Before using, please read this Reference Manual carefully, and keep properly. Alarm 1. This product cannot be caught in or be affected with damp,

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual 1 10/100TX + 1 100FX w/ 1 PoE Injector Industrial Switch User Manual CE Mark Warning This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user

More information

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm 800xA Networks NE801 User Manual Power and productivity for a better worldtm 800xA Networks NE801 User Manual NOTICE This document contains information about one or more ABB products and may include a

More information

16 x E1 G x Ethernet optical multiplexer

16 x E1 G x Ethernet optical multiplexer 16 x E1 G.703 + 4 x Ethernet optical multiplexer Spot-light: 16E1+4Eth Optical multiplexer is state-of-art 16 x E1 G.703 + Ethernet 10/100BaseT fiber multiplexer with logical bandwidth control, QoS, and

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

TRP-C41 User s Manual

TRP-C41 User s Manual TRP-C41 User s Manual Ethernet To Fiber Media Converter User s Manual Printed Oct. 2013 Rev 1.2 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351

More information

FE1&10/100BASE-T Bridge

FE1&10/100BASE-T Bridge USER MANUAL F&10/100BASE-T Bridge Contents 1. Product description... 2 2. Main features... 2 3. Technical specifications... 3 4. Installation and panel description... 4 4.1 Unpacking(stand alone F&10/100BASE-T

More information

Preparing to Install the Cisco AS5350XM Universal Gateway

Preparing to Install the Cisco AS5350XM Universal Gateway CHAPTER 2 Preparing to Install the Cisco AS5350XM Universal Gateway This chapter describes the tasks you must perform before you begin to install the Cisco AS5350XM universal gateway and includes the following

More information

Smart IDU. Digital Microwave Radio SM Sygnus SHC. User s Manual

Smart IDU. Digital Microwave Radio SM Sygnus SHC. User s Manual Smart IDU Digital Microwave Radio SM Sygnus SHC User s Manual 1 CONTENTS Section Page 1 CONTENTS... 2 2 INTRODUCTION... 3 3 INSTALLATION... 4 3.1 PACKING LIST... 4 4 CONFIGURATION... 10 4.1 FUNCTIONAL

More information

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual Lantech IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

More information

Industrial 3-Port Fast Ethernet Media Converter Switches

Industrial 3-Port Fast Ethernet Media Converter Switches Industrial 3-Port Fast Ethernet Media Converter Switches KSD-103-A series KSD-103-B series Installation Guide DOC.081111 1/20 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation

More information

Perle Gigabit Media Converter Module. Installation Guide P/N

Perle Gigabit Media Converter Module. Installation Guide P/N Perle Gigabit Media Converter Module Installation Guide Unmanaged Managed C-1000-M2SC05 C-1000-M2LC05 C-1000-S2LC10 C-1000-S2SC10 C-1000-S2LC40 C-1000-S2SC70 C-1000-S2LC70 C-1000-S1SC10U C-1000-S1SC10D

More information

FE1/10&100Base-T Bridge

FE1/10&100Base-T Bridge FE1/10&100Base-T Bridge Version: V2.0.4 Date: 5.12.2005 Contents Chapter 1 Introduction...3 1.1 Description... 3 1.2 Characteristics... 3 1.3 Technical Parameters... 4 Chapter 2 Operation...5 2.1 Front

More information

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.6.S - 0 CMU 100 / 7.6.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.6.S - 0 User

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

E1/10&100Base-T Bridge (VLAN)

E1/10&100Base-T Bridge (VLAN) E1/10&100Base-T Bridge (VLAN) Version: 2.1.3 Date: 04.15.2005 Contents Chapter 1 Introduction...3 1.1 Description... 3 1.2 Characteristic... 3 1.3 Technical parameters... 3 Chapter 2 Operation...4 2.1

More information

User Manual. RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter

User Manual. RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter User Manual Beijing Raisecom Science & Technology Co., Ltd Contents Chapter 1 RC511/RC512-FE-XX(Rev.A)Series

More information

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.1.S - 0 CMU 100 / 7.1.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.1.S - 0 User manual CMUMU11S

More information

Gigabit Ethernet Media Converter. User Manual

Gigabit Ethernet Media Converter. User Manual Gigabit Ethernet Media Converter User Manual (Version 1.2) Beijing Fibridge Co., Ltd. Contents 1. Overview... 3 2. Features... 3 3. Application... 5 4. Specification... 5 4.1. Ethernet Port... 5 4.2. Fiber

More information

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch 12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:

More information

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed

More information

Industrial Ethernet Switch

Industrial Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the hardened Ethernet Switch. Capable of operating at temperature extremes of -10 C to +60 C, this is the switch of choice for

More information

PIX 535. PIX 535 Product Overview CHAPTER

PIX 535. PIX 535 Product Overview CHAPTER CHAPTER 7 PIX 535 This chapter describes the installation of the PIX 535, and includes the following sections: PIX 535 Product Overview Installing a PIX 535 PIX 535 Feature Licenses Installing Failover

More information

RC801-60B-FV35, RC803-60B-FV35, RC805-60B-FV35 Series Standalone V.35+E1 Dual Interface Fiber Optic Modem. User Manual REV.N

RC801-60B-FV35, RC803-60B-FV35, RC805-60B-FV35 Series Standalone V.35+E1 Dual Interface Fiber Optic Modem. User Manual REV.N RC801-60B-FV35, RC803-60B-FV35, RC805-60B-FV35 Series Standalone V.35+E1 Dual Interface Fiber Optic Modem User Manual REV.N Raisecom Technology Co., Ltd. (05/2006) 1. Cautions Please read the following

More information

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd V C ALIANT OMMUNICATIONS VCL-4 E1 + Ethernet PDH Optical Multiplexer Data Sheet U.K. Valiant Communications (UK) Ltd Central House Rear Office 124 High Street, Hampton Hill Middlesex, TW12 1NS, U.K. E-mail:

More information

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual Fourth Edition, DEC, 2007 www.korenix.com Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User

More information

Quick Start Guide. C-100 Series Switches

Quick Start Guide. C-100 Series Switches Quick Start Guide C-100 Series Switches C-100 SERIES QUICK START GUIDE Warnings and Cautionary Messages!! Warning: This product does not contain any serviceable user parts. Warning: Installation and removal

More information

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP TELECOMMUNICATION INTERNATIONAL, INC. 8F, NO. 8, HSIN ANN

More information

Hardened Media Converter

Hardened Media Converter Quick Start Guide This quick start guide describes how to install and use the hardened media converter. This is the media converter of choice for harsh environments constrained by space. Physical Description

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

Hardened PoE Ethernet Switch

Hardened PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description

More information

Copyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any CVT4K-S Fiber Converter Document Version: V1.0.1 Document Number: NS110100433 Copyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted

More information

Optimux-34 Fiber Optic Multiplexer

Optimux-34 Fiber Optic Multiplexer Data Sheet Optimux-34 Multiple E1, Ethernet, or High-speed Data over E3 or Fiber, up to 110 km (68 miles) Up to 16 E1 links, high-speed data, and Ethernet traffic multiplexed into one E3 copper or fiber

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual LNP-0602 series 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A

More information

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual 10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual v1.02 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to

More information

Fiber optic converter audio and CAN TA OPERATION MANUAL

Fiber optic converter audio and CAN TA OPERATION MANUAL Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.

More information

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001 Installation Guide DOC.050523-EM400X -1- The information contained in this document is subject to change without prior notice. Copyright (C) All

More information

DS-1H05 Ethernet-over-Coax Extender. User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,

More information

RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter. User Manual. Raisecom Technology Co., Ltd.

RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter. User Manual. Raisecom Technology Co., Ltd. RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter User Manual Raisecom Technology Co., Ltd. Dec, 2005 CONTENT 1. SAFETY NOTICE...2 2. OVERVIEW...3 2.1. MODEL DESCRIPTION...3

More information

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet V C ALIANT OMMUNICATIONS VCL-Ethernet over Multi E1 (4/8/16E1) 10/100Base-T / 100Base-FX to 4/8/16E1 Interface Converter Product Brochure & Data Sheet U.K. Valiant Communications (UK) Ltd 1, Acton Hill

More information

Read me first User's Manual Release Note

Read me first User's Manual Release Note Read me first User's Manual Release Note User's Manual Bridge Media Converter Fast Ethernet 10/100Base-TX (RJ-45) To 100Base-FX (ST/SC/LC or POF SC-RJ) 11. -Fiber Technical Specifications Standards :IEEE802.3u

More information

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide EL1142 Series IEC 61850 / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter User s Guide All Rights Reserved Dissemination or reproduction of this document, or its contents,

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual 4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

More information

Perle 10/100 Ethernet Media Converter Module. Installation Guide. P/N (Rev C)

Perle 10/100 Ethernet Media Converter Module. Installation Guide. P/N (Rev C) Perle 10/100 Ethernet Media Converter Module Installation Guide C-110-XXXXX CM-110-XXXXX Unmanaged Module Managed Module P/N 5500307-15 (Rev C) Overview This document contains instructions necessary for

More information

Agilent OBSAI Protocol Tester

Agilent OBSAI Protocol Tester Agilent OBSAI Protocol Tester Hardware Reference Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer Modularized 16E1/T1 Managed Multiplexer FMUX01 Modularized 16E1/T1 + 4x GbE Managed FMUX1 Modularized 16E1/T1 + 4x FE Managed The FMUX01/FMUX1 is a 1U, 19" rack mountable, PDH fiber optic multiplexer that

More information

F /100Mbps Ethernet to 8E1 Converter. Standalone/Module/Chassis User Manual

F /100Mbps Ethernet to 8E1 Converter. Standalone/Module/Chassis User Manual F5-8513 10/100Mbps Ethernet to 8E1 Converter Standalone/Module/Chassis User Manual (Version: V1.5) Beijing Fibridge Co., Ltd. Content 1. General...2 2. Features...2 3. Specification:...2 3.1. E1 Port...2

More information

Optimux-108, Optimux-106

Optimux-108, Optimux-106 Where to buy > Product page > Data Sheet Optimux-108, Multiplexer for 4E1/4T1 and Ethernet or Serial Data Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic link Various fiber

More information

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire

More information

FOMi-40 Fiber Optic Modem with Remote Management

FOMi-40 Fiber Optic Modem with Remote Management Data Sheet FOMi-40 Provides a secure and long-range data link of up to 100 km (62 mi) Selectable data rates from 56 to 2048 kbps Multimode or single mode operation Extended transmission range up to 100

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs VDSL LAN Extender Products LMC5220A (Standalone Set, AC) LMC5221A (Standalone, AC, CO Unit) LMC5222A (Standalone, AC, CPE Unit) LMC5223A (Standalone Set, Multi-Power) LMC5224A (Standalone, Multi-Power,

More information

Rugged MediaConverter

Rugged MediaConverter Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006

More information

F9-480 Series 4/8/16E1 Plus Ethernet Multi-service Multiplexer User Manual

F9-480 Series 4/8/16E1 Plus Ethernet Multi-service Multiplexer User Manual F9-480 Series 4/8/16E1 Plus Ethernet Multi-service Multiplexer User Manual (Version 2.1) Beijing Fibridge Co., Ltd Table of Content 1. Overview...3 2. Features...3 2.1. Hardware Features...3 2.2. Software

More information

FSM-510G Series Ethernet Management Switch Quick Start Guide

FSM-510G Series Ethernet Management Switch Quick Start Guide FSM-510G Series Ethernet Management Switch Quick Start Guide Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easily

More information

Industrial Ethernet Optical Fiber Link Adapter FIB-IE-S User Manual

Industrial Ethernet Optical Fiber Link Adapter FIB-IE-S User Manual http://www.fourstar-dy.com Industrial Ethernet Optical Fiber Link Adapter FIB-IE-S User Manual FOURSTAR Electronic Technology Co., Ltd. All rights reserved Contents Preface.... 3 Copyright....3 Version

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide 1 INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER Installation Guide October 2008 VERSITRON, Inc. 83C Albe Drive Newark, DE 19702 800-537-2296 2 PROPRIETARY DATA All data in this manual is proprietary

More information

Bridge Module. Installation Guide and Users Reference Manual

Bridge Module. Installation Guide and Users Reference Manual Bridge Module Installation Guide and Users Reference Manual This manual contains information to help with the installation and operation of Black Box Corporation's Bridge Modules and 100-Mbps Modules.

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter ClearCube FO-065-1200 series 12-Port Media Converter ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter User s Manual 1 ClearCube Connectivity Systems F6151 Media Converter

More information

Atrie WireSpan 620. User's Manual

Atrie WireSpan 620. User's Manual Atrie WireSpan 620 User's Manual WireSpan 620 Fractional E1/Ethernet Access Unit Installation and Operation Manual (Version 1.00) CONTENTS CHAPTER 1 Introduction.. 1-1 CHAPTER 2 Installation and Setup..

More information

RION ORION TELECOM NETWORKS INC. TELECOM NETWORKS. Optical Multiplexer Product Brochure. Orion Telecom Networks Inc.,

RION ORION TELECOM NETWORKS INC. TELECOM NETWORKS. Optical Multiplexer Product Brochure. Orion Telecom Networks Inc., RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. 16 E1 + Gigabit Ethernet (Wire-Speed) Optical Multiplexer Product Brochure Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. Address: 20100, N

More information

8~14-Port Managed Ethernet Switch

8~14-Port Managed Ethernet Switch 8~14-Port Managed Ethernet Switch Quick Installation Guide Overview The Managed Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easier to prioritize,

More information

F Series 10/100Mbps to 4E1 Converter F User Manual (Version: 3.2)

F Series 10/100Mbps to 4E1 Converter F User Manual (Version: 3.2) F5-4511 Series 10/100Mbps to 4E1 Converter F5-4513 User Manual (Version: 3.2) Beijing Fibridge Co., Ltd. Content 1. Overview...3 2. Features...3 3. Specification...4 3.1 E1 Port...4 3.2 Ethernet Port...4

More information

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the

More information

PIX 520. PIX 520 Product Overview CHAPTER

PIX 520. PIX 520 Product Overview CHAPTER CHAPTER 5 PIX 520 This chapter guides you through the installation of the PIX 520, and includes the following sections: PIX 520 Product Overview, page 5-1 Installing the PIX 520, page 5-4 PIX 520 Feature

More information

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual 8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual Version 1.1 Content Overview... 1 Introduction... 1 Features... 2 Technical Specifications... 3 Packing List... 5 Safety Precaution...

More information

AC Series Fast Ethernet Media Converters AC100SC AC100ST AC100SFP AC100SC.20 AC120SC.20. User Manual

AC Series Fast Ethernet Media Converters AC100SC AC100ST AC100SFP AC100SC.20 AC120SC.20. User Manual AC Series Fast Ethernet Media Converters AC100SC AC100ST AC100SFP AC100SC.20 AC120SC.20 User Manual Version: 1.0.1 October 2016 Caution Electronic Circuit devices are sensitive to static electricity. Dry

More information

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter Lantech IGC-0101DSFP IPGC-0101DSFP 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter User Manual Dec 2016 Recommendation for Shielded network cables STP cables have additional shielding

More information

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA V C ALIANT OMMUNICATIONS Product Brochure U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3 9QN, United Kingdom U.S.A. Valcomm Technologies Inc. 4000 Ponce de Leon,

More information

GYM Bilgi Teknolojileri

GYM Bilgi Teknolojileri www.fibridge-tr.com bilgi@gym-tech.net GYM Bilgi Teknolojileri E1 and V.35 Modem User Manual (Version 1.0) Beijing Fibridge Co., Ltd Table of Content 1. Overview... 1 2. Features... 1 3. Specification...

More information

Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter

Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter Copyright 2008, American Fibertek, Inc. 1107JD Table of Contents Functional Description... 3 Installation... 3 MX2

More information

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide First Edition, February 2012 2012 Moxa Inc. All rights reserved. P/N: 1802001016020 Overview Moxa Industrial Media Converter, which

More information

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters KC-351 Series Installation Guide -1- DOC.070820-KC-351 (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS KC-300DM Series Installation Guide -1- DOC.060215-KC-300D (C) 2003 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in

More information

XPress-Pro SW User Guide

XPress-Pro SW User Guide XPress-Pro SW 92000 User Guide Part Number 900-505 Revision A May 2007 Copyright & Trademark Contacts 2005, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced

More information

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high order legacy traffic (TDM) over SDH/SONET networks Any Traffic Over Fiber Multiplexes up to three E3 or T3 data channels using

More information

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide Copyright January 2004 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 A010430357 The information contained in this document

More information

TVAC25100 TVAC25110 User manual

TVAC25100 TVAC25110 User manual TVAC25100 TVAC25110 User manual Version 11/2010 Original user manual. Keep for future use. 12 Introduction Dear Customer, Thank you for purchasing this product. This product meets the requirements of the

More information

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP. Manual Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T, 1x SFP Ports MICROSENS General The IP protocol has already left the in-house environment and is going to take all remaining communication

More information