Position transmitter SDAT-MHS e [ ]

Size: px
Start display at page:

Download "Position transmitter SDAT-MHS e [ ]"

Transcription

1 Position transmitter SDAT-MHS en Manual e [ ]

2 Translation of the original instructions SDAT-MHS This documentation refers to the following version: From Revision R04. Identification of dangers and instructions on how to avoid them: Warning Dangers which can lead to death or serious injuries. Other symbols: Note Material damage or loss of function. Text designations: Activities which can be carried out in any sequence. 1. Activities which should be carried out in the specified sequence. General lists. 2 Festo SDAT-MHS 1612e

3 1 Product description Overview Characteristics Function and application Analogue output function Switching functions and switching logic Window comparator Cylinder switch function Hysteresis comparator Normally open (NO) and normally closed (NC) contacts Switching output operating mode (SIO) IO-Link operating mode Requirements for product use Installation Electrical Mechanical Commissioning Set set-up mode Scale analogue signal Program switching output Set window comparator Set cylinder switch function Set hysteresis comparator Invert switching logic (NO or NC) Block / unblock operating key Program IO-Link output Operation LED indicators Reset position transmitter to factory setting Disassembly Festo SDAT-MHS 1612e English 3

4 8 Fault clearance Diagnostics via LED General malfunctions Accessories Technical data General IO-Link I-Port Appendix Festo SDAT-MHS 1612e English

5 1 Product description 1.1 Overview Connecting cable 2 Mounting screw 3 Plug M8, rotatable 4 Red LED: Status display Fig. 1 Control sections and connections 5 Green LED: Ready status display 6 Yellow LED: Switching status display 7 Operating key 1.2 Characteristics Feature Order Specification code Position transmitter SDAT- Mounting M Insertable in slot Sensing HS- Hall sensor Sensing range Mxx- Range in mm, xx = 50/80/100/125/160 Operating voltage 1 24 V DC Display L- LED Electrical output SA- PNP or IO-Link and analogue output 4 20 ma Cable characteristic E- Energy chain + robot Cable length 0.3- Cable length 0.3 m Electrical connection M8D M8 rotatable (threaded sleeve) Tab. 1 Overview of variants Festo SDAT-MHS 1612e English 5

6 2 Function and application The position transmitter SDAT-MHS is intended for contactless recording of the piston position of magnetically detectable drives. It is appropriate for use with Festo drives with T-slot (profile slot 8) as well as round cylinders and tie-rod cylinders with mounting kits. The position transmitter SDAT-MHS records the magnetic field of the piston magnet and continuously senses the piston movement in the sensing range. Available output signals include: analogue current signal (4 20 ma) programmable switching output (24 V), IO-Link communication mode ( Chapter 2.3). 6 Festo SDAT-MHS 1612e English

7 2.1 Analogue output function The analogue output provides a path-proportional output signal 4 20 ma in the sensing range of the piston stroke. The analogue output signal can be scaled. The direction of increase of the analogue output signal can be inverted. In the switching output operating mode, the analogue position signal is made available parallel and independent of the position value output of the switching output. The analogue output is switched off in the operating mode IO-Link. A B C 20 ma 4 ma 2 ma 0 mm x mm x = Maximum length of the sensing range (type-dependent) Fig. 2 Characteristic curve, analogue output Signal Description Area 1) 0 ma IO-Link operation error (e.g. broken cable, parameter error) 2 ma piston outside of the sensing range after the operating voltage is A, C switched on 4 ma the piston has left the sensing range in the direction of the falling A output current > 4 ma... < 20 ma piston within the sensing range B 20 ma the piston has left the sensing range in the direction of the rising output current C 1) Area LEERER MERKER., Area A and C: Red LED illuminated Tab. 2 Output signal, analogue output Note With active IO link communications, the analog output is switched off (output current = 0 ma). Festo SDAT-MHS 1612e English 7

8 Scaling of the analogue signal The analogue output signal 4 20 ma is assigned as standard to the complete sensing range. If only a part of the sensing range is used, the analogue value output can be scaled to the sensing range actually used. Resolution and repetition accuracy are not improved through scaling. 20 ma 1 2 Analogue signal Scaled Not scaled 4 ma 2 ma 0 mm 60 mm 120 mm 160 mm 1 Teach point 1 2 Teach point 2 Fig. 3 Scaling of the analogue signal (example SDAT-MHS-M160) 2.2 Switching functions and switching logic Window comparator OUT 1 2 Switching travel hysteresis 1 Teach point 1 2 Teach point 2 Fig. 4 Window comparator IN The teach points (1,2) are linked to the window comparator function. The position of the teach points determines the window width. Hysteresis is not selectable or preset. 8 Festo SDAT-MHS 1612e English

9 2.2.2 Cylinder switch function OUT 1 Switching travel hysteresis IN 1 Teach point Fig. 5 Cylinder switch function The cylinder switch function consists of the switching travel and hysteresis. Hysteresis serves to suppress switching signals in the event of fluctuations around the switching point. The teach value is the middle of the switching travel. Switching travel and hysteresis are not adjustable. For switching travel and hysteresis, values are stored that correspond to a typical electronic cylinder switch in a typical drive Hysteresis comparator OUT 2 1 Switching travel IN 1 Teach point 1 2 Teach point 2 Fig. 6 Hysteresis comparator The teach points (1,2) are linked to the hysteresis comparator function. Teach point 1 (ON) is the switch-on point, teach point 2 (OFF) is the reset point. Teach point 2 establishes the size of the hysteresis Normally open (NO) and normally closed (NC) contacts The switching logic normally open (NO) is set as standard. The function of the switching output is inverted through selection of the normally closed function (NC). Festo SDAT-MHS 1612e English 9

10 2.3 Switching output operating mode (SIO) If the IO-Link/switching output is operated as a switching output, only 1 binary channel can be programmed. The switching output operating mode must be programmed actively via set-up mode (key) ( Chapter 5.3). Either window comparator or cylinder switch function or hysteresis comparator programmable. Switching logic normally closed (NC) or normally open (NO) selectable. Programming via IO-Link protocol (channel BDC1) or operating key on the device. Display switching output ON: Yellow LED illuminated. Output signal 24 V DC (PNP). Note Even if the analogue output has been scaled, the switching output can still be programmed over the entire sensing range. 2.4 IO-Link operating mode In the IO-Link operating mode, programmed switching signals and the continuous position values (digitally coded analogue values) are transferred. There are 4 binary channels available, which can be programmed individually as window comparator or cylinder switch or hysteresis comparator. The continuous position values are always transferred parallel and independent of the position value output of the binary channels. Each channel is adjustable as normally closed (NC) or normally open (NO). Data transmission is serially and digitally coded in the IO-Link protocol. Process data: 12 bit for position data and 4 bit for binary channels ( Chapter 10). Usage of unscreened standard cables of up to 20 m in length is possible. Device description file IODD for every device length Parameters and functions in accordance with Smart-Sensor profile. Support of optional functions Block Parameterisation and Data Storage. Display IO-Link operation: Green LED flashes (1 Hz). Inversion of direction of process data values (PDV). PDV is minimally (standard) or maximally (inverted) at the cable end of the sensor. 10 Festo SDAT-MHS 1612e English

11 3 Requirements for product use Use the product in its original status, without any unauthorised product modifications. Use the SDAT-MHS only for the suitable drives from Festo ( Avoid having magnetic bodies near the position transmitter. These could influence the magnetic field and thereby the behaviour of the sensor. Do not exceed the limit values (e.g. voltages, forces, temperatures). Take into consideration the ambient conditions at the location of use. The device is intended for use in an industrial environment. Measures for interference suppression may need to be implemented in residential areas. Observe the regulations which apply in your location (e.g. from trade associations or from national institutions). Remove all transport packaging. The material used in the packaging has been specifically chosen for its recyclability (with the exception of the oil-impregnated paper which is residual waste). Areas of application and approval by authorities In connection with the UL marking on the product, the information of this section is applicable for compliance with the certification conditions of Underwriters Laboratories Inc. (UL) for the U.S.A. and Canada. Observe the following remarks from UL: UL approval information Product category code File number NRKH, NRKH7 E Considered standards UL and UL , C22.2 No UL mark Product category Control Number Ind. Cont. EQ. (Industrial Control Equipment) 2MD1 Festo SDAT-MHS 1612e English 11

12 Only for connection to a NEC Class 2 supply. Raccorder Uniquement a un circuit de Classe 2. This device is intended to be used with a Class 2 power source or Class 2 transformer in accordance with UL1310 or UL1585. As an alternative a LV/C (Limited Voltage/Current) power source with one of the following properties can be used: This device shall be used with a suitable isolating source such that the maximum open circuit voltage potential available to the product is not more than 30 V DC and the current is limited to a value not exceeding 8 amperes measured after 1 minute of operation. This device shall be used with a suitable isolating source in conjunction with a fuse in accordance with UL248. The fuse shall be rated max. 3.3 A and be installed in the 30 V DC power supply to the device in order to limit the available current. Note that, when more than one power supply or isolating device is used, connection in parallel is not permitted. Electrical and environmental ratings Input voltage Max. 30 V DC, Class 2 Input current 160 ma / max. 4.8 W Analog output 4 20 ma Transistor output max. 30 V DC, 100 ma G.P. Maximum Ambient Temperature 70 C / 158 F Enclosure Type Rating Type 1 12 Festo SDAT-MHS 1612e English

13 4 Installation Installation and commissioning must be carried out only by properly qualified personnel in accordance with these operating instructions. 4.1 Electrical Warning Use only power sources which guarantee reliable electrical isolation of the operating voltage as per IEC/EN Observe also the general requirements for PELV power circuits as per IEC/EN Switched-mode power supplies are permitted, provided that they ensure reliable separation in accordance with EN 60950/VDE Make sure that the operating voltage is switched off. 2. Connect the M8 plug to the connecting cable of the higher-order controller. The tightening torque for the union nut of the plug: Max. 0.3 Nm. Fig. 7 Circuit diagram Pin Allocation Plug 1 Operating voltage +24 V DC M8x1, 4-pin 2 Analogue output 0 20 ma 3 0 V 4 IO-Link/switching output (C/Q line) Tab. 3 Pin allocation of plug connection Festo SDAT-MHS 1612e English 13

14 4.2 Mechanical The mounting position is any desired. ß Nm Nm Internal hexagon socket key 2 Mounting screw Fig. 8 Mechanical installation 3 T-slot (profile slot 8) 4 M8 plug 1. Insert the SDAT-MHS into the T-slot of the drive. 2. Move the piston into an end position of the application. 3. Push the SDAT-MHS in the direction of the piston until the red LED goes out. 4. Tighten the mounting screws hand-tight. max. tightening torque 0.5 Nm. tool: Internal hexagon socket key (size 1.5 mm). 14 Festo SDAT-MHS 1612e English

15 5 Commissioning Installation and commissioning may only be performed in accordance with these instructions by technicians with appropriate qualifications. 1. Switch on the operating voltage. The LEDs illuminate (dependent on the piston position Tab. 4). The device is ready for operation. 5.1 Set set-up mode 1. Press the operating key 3 times within 3 s. Set-up mode: Green and yellow LED flash simultaneously. Note After entry into the set-up mode, if programming is not completed within 60 s, the SDAT-MHS automatically switches into the operating mode 5.2 Scale analogue signal 20 ma 1 2 Analogue signal Scaled Not scaled 4 ma 2 ma 0 mm 60 mm 120 mm 160 mm 1 Teach point 1 2 Teach point 2 Fig. 9 Scaling of the analogue signal (example SDAT-MHS-M160) Requirement: The piston is in the sensing range (red LED off ). 1. Change into the set-up mode ( Chapter 5.1). 2. Press the operating key 5 times in succession. Scale analogue output: The green LED flashes (5 times briefly in succession within 2 s). 3. Move the piston to the starting point of the desired sensing range. 4. Press the operating key. Teach point 1 (starting point of the sensing range) is established (4 ma). Green LED continues to flash, yellow LED flashing at 1 Hz. 5. Move the piston to the end point of the desired sensing range. Festo SDAT-MHS 1612e English 15

16 6. Press the operating key. Teach point 2 (end point of the sensing range) is established (20 ma). Change into the operating mode. Note To invert the direction of increase of the analogue signal: Set teach point 2 (20 ma) on the cylinder axis before teach point 1 (4 ma). 5.3 Program switching output Set window comparator OUT 1 2 Switching travel hysteresis IN 1 Teach point 1 2 Teach point 2 Fig. 10 Window comparator Requirement: The piston is in the sensing range (red LED off ). 1. Change into the set-up mode ( Chapter 5.1). 2. Press the operating key 1 time. Green LED flashes (1 time within 2 s). 3. Move the piston to the 1st switching point (teach point 1). 4. Press the operating key 1 time. Switching point 1 is established. Green LED continues to flash, yellow LED flashing at 1 Hz. 5. Move the piston to the 2nd switching point (teach point 2). 6. Press the operating key 1 time. Switching point 2 is established. Change into the operating mode. 16 Festo SDAT-MHS 1612e English

17 5.3.2 Set cylinder switch function OUT 1 Switching travel hysteresis IN 1 Teach point Fig. 11 Cylinder switch function Requirement: The piston is in the sensing range (red LED off ). 1. Change into the set-up mode ( Chapter 5.1). 2. Press the operating key 2 times. Green LED flashes (2 times briefly in succession within 2 s). 3. Move the piston to the switching point (teach point 1). 4. Press the operating key 1 time. The switching point is established. Change into the operating mode. Festo SDAT-MHS 1612e English 17

18 5.3.3 Set hysteresis comparator OUT 2 1 Switching travel IN 1 Teach point 1 2 Teach point 2 Fig. 12 Hysteresis comparator Requirement: The piston is in the sensing range (red LED off ). 1. Change into the set-up mode ( Chapter 5.1). 2. Press the operating key 3 times. Green LED flashes (3 times briefly in succession within 2 s). 3. Move the piston to the switch-on point (teach point 1). 4. Press the operating key 1 time. The switch-on point is established. Green LED continues to flash, yellow LED flashing at 1 Hz. 5. Move the piston to the reset point (teach point 2). 6. Press the operating key 1 time. The reset point is established. Change into the operating mode Invert switching logic (NO or NC) 1. Change into the set-up mode ( Chapter 5.1). 2. Press the operating key 4 times. Green LED flashes (4 times briefly in succession within 2 s). Yellow LED illuminated: Currently set switching logic is NC. Yellow LED not illuminated: Currently set switching logic is NO. 3. Press the operating key. The switching logic is inverted. Change into the operating mode. 18 Festo SDAT-MHS 1612e English

19 5.4 Block / unblock operating key In the IO-Link mode, the operating key is automatically and always blocked. In the switching output operating mode, the operating key is unlocked as standard. But it can be blocked in the IO-Link mode for the switching output operating mode: 1. Produce IO-Link mode. 2. Select key block for switching output operating mode in the IO-Link parameter menu: device access block, local user interface block. LED display with blocked operating key: If the operating key is pressed: Green LED flashes 3 seconds at 3 Hz. Yellow LED displays the current status of the switching output. Red LED is illuminated only when the piston is outside the sensing range. 5.5 Program IO-Link output The IO-Link function cannot be set via the operating keys on the device. All settings for set-up, commissioning and parameterisation are made in the higher-level controller of the IO-Link master. 1. Load the device description file IODD ( belonging to the device into the interpreter of the IO-Link masters. 2. Connect the IO-Link/switching output to the IO-Link master. 3. Program the device. Observe the instructions on this in the operating instructions of the IO-Link masters. Note If the device detects an error during commissioning, it is displayed on the user interface of the IO-Link master and the programming option is closed. Festo SDAT-MHS 1612e English 19

20 6 Operation 6.1 LED indicators Status signals in normal operation LED indicator Yellow Green Red Description Green LED illuminated: Ready status (yellow: Any, red: Off ). Analogue output function or switching output operating mode. Piston within the sensing range. Green LED flashing at 1 Hz: Ready status. IO-Link operating mode. Yellow and green LEDs illuminated: Ready status. Switching output switched. Piston in the range of a programmed function. Green LED flashing 3 seconds at 3 Hz while the operating key is pressed: Operating key blocked. Red LED illuminated: Status display. Piston outside the sensing range. Tab. 4 LED displays in normal operation 20 Festo SDAT-MHS 1612e English

21 Interrogate configuration The currently set configuration can be interrogated in the set-up mode. 1. Change into the set-up mode ( Chapter 5.1). 2. Press the operating key 6 times. Yellow, green and red LED flash cyclically according to the current configuration ( Tab. 5). Another keystroke ends the interrogation and the SDAT-MHS changes into the operating mode. Without a keystroke, the SDAT-MHS automatically changes into the operating mode after 60 s. LED display Description Green Function No display Disabled 1 x flashing Window comparator 2 x flashing Cylinder switch function 3 x flashing Hysterisis comparator Yellow Switching logic 1 x flashing Normally closed (NC) 2 x flashing Normally open (NO) Red Scaling 1 x flashing User-configured 2 x flashing Total sensing range Tab. 5 Status displays in the set-up mode 6.2 Reset position transmitter to factory setting Parameter Switching function Switching logic Scaling Factory setting None Normally open (NO) Total sensing range Tab. 6 Factory settings SDAT-MHS Calll factory setting 1. Change into the set-up mode ( Chapter 5.1). 2. Press the operating key 10 times. Yellow, green and red LED flash at 1 Hz. 3. Press the operating key. The position transmitter is reset to factory settings. Change into the operating mode. Festo SDAT-MHS 1612e English 21

22 7 Disassembly 1. Switch off the operating voltage. 2. Separate the connections from the SDAT-MHS. 3. Loosen the mounting screws ( Fig. 8). 4. Take the SDAT-MHS out of the T-slot of the drive. 8 Fault clearance 8.1 Diagnostics via LED LED display Yellow Green Red Possible cause Voltage supply defective Remedy Secure the power supply. All LEDs off Connecting cable defective Replace the connecting cable. Sensor defective Replace device. Sensor defective Switch power supply on/off. Replace device. Red LED flashing Short circuit/overload at the Eliminate short circuit/overload. switching output Yellow LED flashing at 3 Hz Parameter error Reset device to factory setting ( Chapter 6.2). Yellow LED flashing at 3 Hz Green LED flashing at 1 Hz Communication error in the IO-Link mode Check IO-Link master. Restart communication. Check C/Q line. Tab. 7 LED indicators with malfunctions 22 Festo SDAT-MHS 1612e English

23 8.2 General malfunctions Note If the device detects an error during the IO-Link operation a status signal is emitted on the IO-Link master. The IO-Link/switching output is not blocked. Malfunction Possible cause Remedy Incorrect or unexpected Inappropriate drive Use an appropriate drive. signals at the analogue output Device defective Replace device. Switching output does not switch corresponding to the settings No operating voltage or impermissible operating voltage Short circuit or overload at the output Magnetic objects in close proximity to the position transmitter Short circuit or overload at the output Device defective Comply with operating voltage range. Eliminate short circuit/overload. Prevent magnetic objects being in close proximity. Remedy short circuit / overload. Replace device. Settings cannot be edited Access protection active Release key (only possible via IO-Link). Tab. 8 Possible malfunctions 9 Accessories Accessories Festo SDAT-MHS 1612e English 23

24 10 Technical data 10.1 General SDAT-MHS Approval certificate RCM, c UL us - Listed (OL) CE marking ( Declaration of conformity) In accordance with EU EMC Directive Note on materials RoHS-compliant Input signal/measuring element Sensing range 1) [mm] Signal processing Typical sampling interval [ms] 1 Max. speed of travel [m/s] 3 Output, general Displacement resolution [mm] 0.05 Switching output Switching output PNP Repetition accuracy of switching point [mm] 0.1 Hysteresis [mm] 0.3 Analogue output Analogue output [ma] 4 20 Sensitivity [ma/mm] Typical linearity error [mm] ± 0.25 Repetition accuracy [mm] 0.1 Max. load resistance of current output [Ω] 500 Electronics Operating voltage DC [V] Typical signal running time [ms] < 2 Electromechanical Cable length [m] 0.3 Conductor nominal cross section [mm 2 ] 0.1 Mechanical system Max. tightening torque [Nm] 0.5 Housing material information PA reinforced, polyester, high-alloy stainless steel, nickel-plated brass Immission/emission Ambient temperature [ C] Ambient temperature flexible cable installation [ C] Degree of protection (as per EN 60529) IP65/IP68 (condition IP68: Test duration 24 h) 1) Type-dependent Tab. 9 Technical data SDAT-MHS 24 Festo SDAT-MHS 1612e English

25 10.2 IO-Link SDAT-MHS Protocol version Device V1.1 Profile Smart Sensor Profile Function classes 0x8000: Identification 0x8001: Binary Data Channel 0x8002: Process Data Variable 0x8003: Diagnosis 0x8004:Teach Channel Communication mode COM3 (230,4 kbaud) Process data length IN 2 Byte Port class A, 4-pin Device-ID 0x x x x x Tab. 10 Physical layer Process data record: 2 bytes Bit Process data Process Data Variable (PDV) Tab. 12 BDC4 1) BDC3 1) BDC2 1) BDC1 1) Data Position switch 4 switch 3 switch 2 switch 1 Type Unsigned Integer Boolean 1) BDC = Binary Data Channel Tab. 11 Process data content Raw data Device length Sensing range [mm] PDV Min. OoR 1) PDV Minimum value of nominal sensing range PDV Maximum value of nominal sensing range PDV max. OoR 2) PDV OoR after Power ON 3) -M M M M M ) Min OoR (OoR = Out of range): Minimum value of the sensing range 2) Max OoR (OoR = Out of range): Maximum value of the sensing range 3) OoR after Power ON: Outside of the sensing range when operating voltage is applied Tab. 12 Range of values of the process data variables (PDV) for the device lengths Festo SDAT-MHS 1612e English 25

26 Process data with use of IODD Device length Sensing range [mm] PDV Min. OoR 1) PDV Minimum value of nominal sensing range PDV Maximum value of nominal sensing range PDV max. OoR 2) PDV OoR after Power ON 3) -M M M M M ) Min OoR (OoR = Out of range): Minimum value of the sensing range 2) Max OoR (OoR = Out of range): Maximum value of the sensing range 3) OoR after Power ON: Outside of the sensing range when operating voltage is applied Tab. 13 Range of values of the process data variables (PDV) with use of IODD for the device lengths Index Subindex Name Default value (example M50) Access 1) Length Format U M S 0x System Command 0x000C 0 Device Access Locks 2) Tab. 15 W W 1 byte Unsigned Integer 0 = Unlocked R R/W R/W 2 bytes Record 1 = Locked 0x Vendor Name Festo AG & Co.KG R R R 64 bytes String 0x Vendor Text R R R 64 bytes String 0x Product Name SDAT-MHS- R R R 64 bytes String M50-1L-SA-E-0.3-M8 0x Product ID 3) R R R 64 bytes String 0x Product Text Position transmitter R R R 64 bytes String 0x Serial-Number R R R 16 bytes String 0x Hardware REVxy R R R 64 bytes String Revision 0x Firmware REVxy R R R 64 bytes String Revision 0x Application *** R/W R/W R/W 32 bytes String Specific Tag 4) 0x Process Data Input Tab. 11 R R R 2 bytes Record 1) Authorisation group U = user, M = maintenence, S = specialist; Access W = write, R = read, R/W = read and write, = no access 2) Bit 0: Lock parameter write access; Bit1: Lock data storage; Bit3: Lock local user interface (operating key) 3) Festo part number 4) Value defined by user Tab. 14 Service data 26 Festo SDAT-MHS 1612e English

27 Value Access 1)2) Length Format Comment U M S 128 W 1 byte Unsigned Integer Reset Device 130 W Restore Factory Settings 176 W Reset Warnings 160 W W Teach SP1 BDC1 3) 161 W W Teach SP2 BDC1 3) 162 W W Teach SP1 BDC2 3) 163 W W Teach SP2 BDC2 3) 164 W W Teach SP1 BDC3 3) 165 W W Teach SP2 BDC3 3) 166 W W Teach SP1 BDC4 3) 167 W W Teach SP2 BDC4 3) 168 W W Teach scale start analogue output 169 W W Teach scale end analogue output 1) Authorisation group U = user, M = maintenence, S = specialist; access W = write, = no access 2) If access = write, an attempted read access causes the error code 0x8101 to be returned 3) Access also possible through the standard function class 0x8004 Teach Channel of the Smart Sensor Profile Tab. 15 System commands Festo SDAT-MHS 1612e English 27

28 Index Subindex Name Default value (example M50) 1) Access 2) Length Format 3) U M S BDC1 0x003C 1 Setpoint SP1 175 R R/W R/W 2 bytes Unsigned 2 Setpoint SP bytes integer 0x003D 1 Switchpoint logic 0 1 byte 2 Switchpoint mode 0 1 byte 3 Switchpoint hysteresis 5 2 bytes BDC2 0x003E 1 Setpoint SP1 275 R R/W R/W 2 bytes Unsigned 2 Setpoint SP bytes integer 0x003F 1 Switchpoint logic 0 1 byte 2 Switchpoint mode 0 1 byte 3 Switchpoint hysteresis 5 2 bytes Analogue current output 0x Scale start 1 R R/W R/W 2 bytes Unsigned 2 Scale end bytes integer PDV 0: Normal, 1: Inverted, not for analogue current output 0x PDV inversion 0 R R/W R/W 1 byte Unsigned integer BDC3 0x Setpoint SP1 375 R R/W R/W 2 bytes Unsigned 2 Setpoint SP bytes integer 0x Switchpoint logic 0 1 byte 2 Switchpoint mode 0 1 byte 3 Switchpoint hysteresis 5 2 bytes BDC4 0x Setpoint SP1 475 R R/W R/W 2 bytes Unsigned 2 Setpoint SP bytes integer 0x Switchpoint logic 0 1 byte 2 Switchpoint mode 0 1 byte 3 Switchpoint hysteresis 5 2 bytes 1) Raw data without use of IODD 2) Authorisation group U = user, M = maintenence, S = specialist; access R = read, R/W = read and write 3) Code BDC1 BDC4 Tab. 17 Tab. 16 Parameters 28 Festo SDAT-MHS 1612e English

29 Name Code Setpoint SP1/SP bit position values Switchpoint logic 0 = output signal not inverted; 1 = output signal inverted Switchpoint mode 0 = deactivated; 1 = cylinder switch, 2 = window comparator, 3 = hysteresis comparator Switchpoint hysteresis Fix: 5 1) Range of values LEERER MERKER Tab. 17 Code switch point parameter Error code Mode Type Comment 0x4000 (Dis)appear Error Temperature error 0x5000 (Dis)appear Error Hardware defective 0x5111 (Dis)appear Warning Voltage too low 0x6320 (Dis)appear Error Parameter error 0x8CA0 (Dis)appear Error Magnetic field too weak, inappropriate drive 0xFF91 SingleShot Notification Data storage upload request Tab. 18 Error codes Festo SDAT-MHS 1612e English 29

30 10.3 I-Port Note In principle, the data of the IO-Link specification apply ( chap.10.2). For specifications on the process data contents Tab. 11. Index Name Default value Access 1) Length 0x0040 Device attributes 0x00 R/W 1 byte 0x0041 Extended parameters 0x0000 R/W 2 bytes 0x0042 Diagnosis parameter 0x0000 R 2 bytes 0x0043 Device specific parameters Tab. 20 R/W 8 bytes 0x00FE I-Port Revision 0x0101 R/W 2 bytes 1) Access R = read, R/W = read and write Tab. 19 Additionally supported parameters in accordance with I-Port specification Byte IO-Link Index 0x003C 0x003D Subindex Function 1) SP1 SP2 Logic Mode HY Byte high low high low high low Default value 0x00 0xAF 0x00 0xFA 0x00 0x00 0x00 0x05 1) Parameter coding Tab. 17 Tab. 20 Device Specific Parameters 30 Festo SDAT-MHS 1612e English

31 11 Appendix SIO operation Switching output status ON ON, if OoR 3 x Key combination invalid Abort Yellow + Green ON for 0.5 s 3 s t > 60 s From each status in the diagram Errors Yellow OFF Green OFF Red flash 3 Hz Set-up mode Yellow + Green flash simultaneously ON, if OoR 1 x Window comparator Yellow OFF 1 x flash briefly / 2 s Red OFF, if in range 1) 1 x Teach point 1 Flashes 1 x flash briefly / 2 s Red OFF, if in range 1) 1 x Teach point 2 2 x Cylinder switch function Yellow OFF 2 x flash briefly / 2 s Red OFF, if in range 1) 1 x Teach point 3 x Hysterisis comparator Yellow OFF 3 x flash briefly / 2 s Red OFF, if in range 1) 1 x Teach point 1 Flashes 3 x flash briefly / 2 s Red OFF, if in range 1) 1 x Teach point 2 4 x Switching logic NO/NC ON if NO / OFF if NC 4 x flash briefly / 2 s Red OFF, if in range 1) 1 x Inverting NO or NC 5 x Scale Yellow OFF 5 x flash briefly / 2 s Red OFF, if in range 1) 1 x Teach point 1 (4 ma) Flashes 5 x flash briefly / 2 s Red OFF, if in range 1) 1 x Teach point 2 (20 ma) Display configuration: Cyclical flash signals in the sequence green - yellow - red 6 x Switching logic: 1 x - normally closed (NC), 2 x - normally open (NO) Function: 0 x - deactivated, 1 x - window comparator, 2 x - cylinder switch function, 3 x - hysteresis comparator Scaling: 1 x - user-configured, 2 x - total sensing range 10 x Reset Yellow + green + red flash simultaneously at 1 Hz 1 x Factory setting Switching function: None Switching logic: Normally open (NO) Scaling: Total sensing range 1 x = Press operating key (e.g.: 1 x) = LED illuminated / LED flashing / LED OFF (e.g.: Green LED) 1) Teaching of a position out-of-range (OoR) causes the red LED to flash until the magnet is back in the sensing range (in range). Fig. 13 Settings via the operating key and LED indicators (not IO-Link operation) Festo SDAT-MHS 1612e English 31

32 Copyright: Festo AG & Co. KG Postfach Esslingen Germany Phone: Fax: Reproduction, distribution or sale of this document or communication of its contents to others without express authorization is prohibited. Offenders will be liable for damages. All rights reserved in the event that a patent, utility model or design patent is registered. service_international@festo.com Internet: Original: de

Position transmitters SDAT-MHS for T-slot

Position transmitters SDAT-MHS for T-slot Key features General Position transmitters are used to provide feedback on piston movement in pneumatic drives. They are situated between simple cylinder switches and expensive displacement encoders, both

More information

Proximity sensors SME-8M, for T-slot Technical data Magnetic reed

Proximity sensors SME-8M, for T-slot Technical data Magnetic reed Function e.g., 3-wire, with cable e.g., 3-wire, with plug Magnetic reed measuring principle Insertable in the slot from above, does not protrude over the cylinder profile Cable clip and inscription labels

More information

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ]

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ] System CPX-E IO-Link master module CPX-E-4IOL- Description Protocol IO-Link Function Parameterisation 877 27-7 [879] IO-Link master module CPX-E-4IOL- Original instructions CPX-E-4IOL- -E N IO-Link is

More information

Pressure sensors SPAN

Pressure sensors SPAN Features At a glance Communication interface Convenient design Compact design 30x30 mm Degree of protection IP40 Reduced weight with QS4 Universal pressure measurement Pressure and vacuum 13 pressure measuring

More information

IO-Link parameter description

IO-Link parameter description Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure

More information

Motion Terminal VTEM. Description. Motion App #02. Proportional directional control valve [ ]

Motion Terminal VTEM. Description. Motion App #02. Proportional directional control valve [ ] Motion Terminal VTEM Description Motion App #02 Proportional directional control valve 8071736 2017-12 [8071738] VTEM Translation of the original instructions VTEM-MA02-EN Firefox is a registered trademark

More information

Pressure sensors SPAE

Pressure sensors SPAE Key features Function The SPAE is an electronic pressure sensor with piezoresistive pressure measuring cell, integrated signal processing, numerical percentage pressure indicator, control keys and a switching

More information

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-... Positioner CMSX-...-C-U-F-.... CMSX-SE-... (linear) 5 Festo AG & Co. KG Postfach Esslingen Germany +9-0 www.festo.com (en) Operating instructions 80595 0a [80595] aj 9 8 Housing cover Inspection window

More information

Pressure sensors SPAE

Pressure sensors SPAE Key features At a glance Single-button operation 7-segment display Various pneumatic connection options Switching status indication Choice of pressure ranges Function The SPAE is an electronic pressure

More information

Controller CMXH. Description STO. Safe Torque Off (STO) [ ]

Controller CMXH. Description STO. Safe Torque Off (STO) [ ] Controller CMXH Description STO Safe Torque Off (STO) 8062612 1603 [8062614] CMXH Translation of the original instructions CMXH-STO-EN Identification of hazards and instructions on how to prevent them:

More information

IO-Link parameter description

IO-Link parameter description Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure

More information

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ] Compact performance Brief description CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8 English 8080251 2017-11e [8080244] Translation of the original instructions Documentation on the

More information

Motion Terminal VTEM. Description. Motion App #04. Model-based proportional pressure regulation [ ]

Motion Terminal VTEM. Description. Motion App #04. Model-based proportional pressure regulation [ ] Motion Terminal VTEM Description Motion App #04 Model-based proportional pressure regulation 8086805 2018-05 [8086807] VTEM Translation of the original instructions VTEM-MA04-E N Firefox is a registered

More information

Proximity sensors SME-8, for T-slot Technical data Magnetic reed

Proximity sensors SME-8, for T-slot Technical data Magnetic reed Function e.g. N/O contact, with cable, 3-wire Magnetic reed measuring principle Insertable in the slot lengthwise e.g. N/O contact, with plug, 3-pin SME-8-SL Sturdy thanks to long guides Plug directly

More information

Vacuum generator. Operating instructions b [ ]

Vacuum generator. Operating instructions b [ ] Vacuum generator OVEM- -LK en Operating instructions 8079732 2017-10b [8079734] Original instructions OVEM- -LK-DE Identification of hazards and instructions on how to prevent them: Warning Hazards that

More information

Flow sensors SFAB Key features

Flow sensors SFAB Key features Key features At a glance Quick and secure installation thanks to QS fitting Display can be rotated 270 Manifold assembly of the sensor via H-rail or individual assembly via adapter plate for wall mounting

More information

Proximity sensors, block design

Proximity sensors, block design Proximity sensors, block design Proximity sensors, block design Product range overview Measuring principle Version Type Mounting Switching element function Switching Electrical connection N/O contact N/C

More information

Proximity sensors, round design

Proximity sensors, round design Proximity sensors, round design Proximity sensors, round design Product range overview Measuring principle Magnetoinductive Version Type Assembly Switching element function Switch output Electrical connection

More information

Fork light barriers SOOF

Fork light barriers SOOF Product range overview Method of measurement Size Min. object diameter Max. switching frequency Switching output Type of light Page/ Internet [mm] [mm] [Hz] Metal light barrier SOOF-M- -C30 30x35 0.5 4,000

More information

IO-Link parameter description

IO-Link parameter description Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure

More information

Terminal CPX. Electrical interface CPX CTEL 4 M12 5POL. Description. CTEL master module. I-Port a [ ]

Terminal CPX. Electrical interface CPX CTEL 4 M12 5POL. Description. CTEL master module. I-Port a [ ] Terminal CPX Electrical interface CPX CTEL 4 M12 5POL Description CTEL master module I-Port 574601 1411a [8041791] Electrical interface CPX CTEL 4 M12 5POL Translation of the original instructions P.BE-CPX-CTEL-EN

More information

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-... Positioner CMSX-...-C-U-F-.... CMSX-SE-... (linear) Festo AG & Co. KG Postfach Esslingen Germany +9-0 www.festo.com aj 9 8 (en) Operating instructions 8088 09NH [8080] Original: de Positioner CMSX... English

More information

Pressure sensors SPAW with display

Pressure sensors SPAW with display Key features At a glance 9 pressure ranges from 1 +1 bar up to 0 +100 bar 4-digit LED display, easy to read, robust Protection class IP67 320 rotatable display 1% accuracy, 0.15% repetition accuracy Temperature

More information

Connecting cables for valves, plug pattern ZC, metric screw Type codes

Connecting cables for valves, plug pattern ZC, metric screw Type codes Type codes NEBV Z4 WA 2 L R E 5 N M8 G 3 S1 Function NEBV Connecting cables for valves Connection technology on left, field device side Z4 Socket, plug pattern ZC, metric screw Cable outlet left WA Angled

More information

Proximity sensors SMT/SME-10, for C-slot

Proximity sensors SMT/SME-10, for C-slot Proximity sensors SMT/SME-10, for C-slot q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ] CPX-Terminal Brief description CPX analogue I/O modules CPX-2AE CPX-4AE CPX-2AA English 8080173 2017-11e [8080175] Translation of the original instructions Documentation on the product For all available

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

CPX-E-CEC-... Controller. Description Function, Parameterisation [ ]

CPX-E-CEC-... Controller. Description Function, Parameterisation [ ] CPX-E-CEC-... Controller Description Function, Parameterisation 8071235 8071235 2018-09 [8071237] Translation of the original instructions CODESYS, EtherCAT, MODBUS are registered trademarks of the respective

More information

GEMÜ 1235 Electrical position indicator

GEMÜ 1235 Electrical position indicator Electrical position indicator Features Communication and programming interface IO-Link Adjustable switch point tolerances Speed-AP function for fast mounting and initialisation High visibility position

More information

Flow sensors SFAM Key features

Flow sensors SFAM Key features Key features At a glance Threaded mounting of individual device with stabilising zone Can be combined with MS6 or MS9 series service units Illuminated LCD display with blue background and white 9-segment

More information

Pressure transmitters SPTE

Pressure transmitters SPTE Key features At a glance Compact design Very lightweight Various pneumatic connection options Output signal: 0 10 V or 1 5 V Choice of pressure ranges Pneumatic connections Push-in sleeve Push-in connector

More information

Pressure sensors SDE1, with display

Pressure sensors SDE1, with display Product range overview Method of measurement Piezoresistive pressure sensor with display Operating voltage Measured variable Pressure measuring range Pneumatic connection Type of mounting Electrical output

More information

Pressure sensors SPAE

Pressure sensors SPAE Key features At a glance Single-button operation 7-segment display Various pneumatic connection options Switching status indication Choice of pressure ranges Function The SPAE is an electronic pressure

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing Dimensioned drawing en 2-214/2 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Largely surface-independent function, ideal for the detection of liquids,

More information

Pressure sensors SPAB, with display

Pressure sensors SPAB, with display Key features, product range overview At a glance Variants: Plug M8x1 with electric adapter SASC Plug, square design L1 Cable version with connecting cable NEBS Compact design 30 x 30 mm Multi-coloured,

More information

Sensor boxes SRBG Key features

Sensor boxes SRBG Key features Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn

More information

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide BNI IOL104002Z046 IOLink 1.1 Sensor hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL104002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing ADVANCED ultrasonic sensors with 2 switching outputs Dimensioned drawing en 4-214/12 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Function largely

More information

Fork light barriers SOOF

Fork light barriers SOOF Product range overview Method of measurement Size Min. object diameter Max. switching frequency Switching output Type of light Page/ Internet [mm] [mm] [Hz] Metal light barrier SOOF-M- -C30 30x35 0.5 4,000

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Operating instructions. ProcessLine analogue module AC / / 2012

Operating instructions. ProcessLine analogue module AC / / 2012 Operating instructions ProcessLine analogue module AC2916 739089 / 01 06 / 2012 Contents 1 Safety instructions... 3 2 Functions and features... 4 3 Operating and display elements... 4 4 Electrical connection...

More information

Controller CMXH-ST2 Key features

Controller CMXH-ST2 Key features Key features At a glance The controller controls two servo motors which drive an H-shaped rotating toothed belt. The toothed belt moves a slide, whose position is calculated by the controller from the

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide BNI IOL102002Z019 IOLink 1.1 sensor hub With extension port User s Guide Balluff Network Interface / IOLink BNI IOL102002Z019 Inhalt 1 Notes for the user 4 1.1. About this manual 4 1.2. Structure of the

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-... Positioner CMSX-...-C-U-F-... Festo AG & Co. KG Ruiter Straße 8 Esslingen Germany +9-0 www.festo.com Product overview. Function The CMSX digital electropneumatic positioner enables simple and efficient

More information

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status:

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status: OPT2041 Fiber Optic Cable Sensor Operating Instructions Available as PDF only Status: 18.06.2018 www.wenglor.com Index 1. Proper Use 3 2. Safety Precautions 3 3. General Information Regarding the Device

More information

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions Pressure switch Type HEDE10.../1/ RE 30276-B/10.10 Replaces: 06.10 Operating instructions 2/20 Bosch Rexroth AG HEDE10.../1/ RE 30276-B/10.10 Contents 1 Overview of menu...3 2 Safety note... 4 3 Operating

More information

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL322E12 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL322E12 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

Optical distance sensors. Dimensioned drawing

Optical distance sensors. Dimensioned drawing Optical distance sensors Dimensioned drawing We reserve the right to make changes DS_ODS10L1_25M8L_en_50129321.fm en 04-2016/08 50129321 100 25000mm Measurement range up to 25000mm on HighGain foil Analog

More information

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL302002Z046 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL302002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical

More information

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A User s Guide Table of contents 1 Safety 2 1.1. Installation and startup 2 1.2. General safety instructions 2 Hazardous

More information

BNI IOL-104-S01-Z012-C02

BNI IOL-104-S01-Z012-C02 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax

More information

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

FESTO. Документация. Датчики положения SRBS. По вопросам продаж и поддержки обращайтесь:

FESTO. Документация. Датчики положения SRBS. По вопросам продаж и поддержки обращайтесь: FESTO Документация Датчики положения SRBS По вопросам продаж и поддержки обращайтесь: Архангельск (8182)63-90-72 Астана +7(7172)727-132 Белгород (4722)40-23-64 Брянск (4832)59-03-52 Владивосток (423)249-28-31

More information

Retro-reflective photoelectric sensors with polarization filter. Dimensioned drawing

Retro-reflective photoelectric sensors with polarization filter. Dimensioned drawing Dimensioned drawing en 01-2016/07 50130059 1,5 khz 0 3.5m 10-30 V DC We reserve the right to make changes DS_PRK3CT_Flaschen_en_50130059.fm Polarized retro-reflective photoelectric sensor with autocollimation

More information

Operating instructions. UM18-2 Pro. Ultrasonic sensors

Operating instructions. UM18-2 Pro. Ultrasonic sensors Operating instructions UM18-2 Pro Ultrasonic sensors EN Copyright protection! This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing Optical laser distance sensors Dimensioned drawing We reserve the right to make changes DS_ODSL96BMLTOFS12_en_50117984-01.fm en 03-2013/01 50117984-01 18-30 V DC 0.3 10m Measurement range up to 10000mm

More information

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE Switch output and analog output Selectable sound lobe width Synchronization options

More information

Pressure sensors SDE3, with display

Pressure sensors SDE3, with display Pressure sensors SDE3 Key features At a glance SDE3- -M plug version, plug M8x1 and M12x1 SDE3- -FQ, cable with plug Fast H-rail, wall or surface mounting Fast front panel mounting High-contrast, two-colour

More information

Electronic Temperature Controller. Instruction Manual Version

Electronic Temperature Controller. Instruction Manual Version Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found

More information

Controller CECC-X-M1. Brief description. Controller CECC X M1 CECC X M1 MV CECC X M1 MV S a [ ]

Controller CECC-X-M1. Brief description. Controller CECC X M1 CECC X M1 MV CECC X M1 MV S a [ ] Controller CECC-X-M1 Brief description Controller CECC X M1 CECC X M1 MV CECC X M1 MV S1 8079349 2017-09a [8074647] PI PROFIBUS PROFINET, CANopen, CODESYS, EtherCAT, EtherNet/IP, IO-Link, and MODBUS are

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042 BNI IOL102000Z012 BNI IOL104000Z012 BNI IOL104S01Z012 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302000Z012 BNI IOL302S01Z012 BNI IOL302000Z042 User s Guide Inhalt 1 Notes for the user 2 1.1. About

More information

Proximity sensors, block-shaped Product range overview

Proximity sensors, block-shaped Product range overview Proximity sensors, block-shaped Product range overview Measuring Version Type Assembly Switching element function Switch output Electricalconnection principle N/C contact Cable Plug Magneto- Operating

More information

Pressure sensors SDE5

Pressure sensors SDE5 q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide BNI IOL302000Z013 BNI IOL302S01Z013 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ013 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

Your Global Automation Partner. Teachable Capacitive Sensors. Operating Instructions

Your Global Automation Partner. Teachable Capacitive Sensors. Operating Instructions Your Global Automation Partner BCT- Teachable Capacitive Sensors Operating Instructions 2 Hans Turck GmbH & Co. KG T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com 1 About These Instructions

More information

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx EU Directive 2004/108/EC (EMC Directive) and EMC Law Generic Standards: EN 61000-6-4 (Emissions), EN 61000-6-2 (Interference Immunity) Emissions testing: Radio interference emissions EN 55011 Group 1,

More information

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date: Documentation Fan cartridge for EtherCAT and Bus Terminals Version: Date: 1.5 2017-08-07 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

Proximity sensors SMT/SME-8, for T-slot

Proximity sensors SMT/SME-8, for T-slot Proximity sensors SMT/SME-8, for T-slot q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions Optical distance sensor O1D / / 2012 Operating instructions Optical distance sensor O1D106 UK 704204 / 01 08 / 2012 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...4 3 Functions and

More information

Laser retro-reflective photoel. sensors with polariz. filter for bottles. Dimensioned drawing

Laser retro-reflective photoel. sensors with polariz. filter for bottles. Dimensioned drawing Technical data and description PRK3CL Laser retro-reflective photoel. sensors with polariz. filter for bottles Dimensioned drawing en 01-2016/07 50132447 3 khz 0 500mm 10-30 V DC We reserve the right to

More information

Proximity sensors SMT/SME-8, for T-slot

Proximity sensors SMT/SME-8, for T-slot Proximity sensors SMT/SME-8, for T-slot q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

BTL6-U101-M -A/B/Y/Z-S4 User s Guide

BTL6-U101-M -A/B/Y/Z-S4 User s Guide User s Guide english www.balluff.com 1 Notes to the user 5 1.1 Validity 5 1.2 Symbols and conventions 5 1.3 Scope of delivery 5 1.4 Approvals and markings 5 1.5 Abbreviations 5 2 Safety 6 2.1 Intended

More information

Capacitive Proximity Switches BCS R08RRE MicroBox

Capacitive Proximity Switches BCS R08RRE MicroBox Capacitive Proximity Switches BCS R08RRE MicroBox User's Guide english www.balluff.com english 1 Content Validity... 3 Notes to the user... 3 Symbols and conventions... 3 Downloading further instructions...

More information

Electronic Level Switch ENS 3000

Electronic Level Switch ENS 3000 Electronic Level Switch ENS 3000 Description: The ENS 3000 is an electronic level switch with integrated display. The instrument has 1, 2 or 4 switching outputs and an analogue output signal is available

More information

Pressure sensors SDE5

Pressure sensors SDE5 Key features At a glance SDE5- -M8 Plug version, plug M8x1, 3-pin SDE5- -K Cable version, 2.5 m long, 3-wire Linkable wall bracket with clip-in facility for sensors (included in the scope of delivery)

More information

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: CU8860-0000 USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: 2006-02-20 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

Super universal modules

Super universal modules s 8 174 TX-I/O Super universal modules TXM1.8X TXM1.8X-ML Two fully compatible versions: TXM1.8X: 8 inputs/outputs with LED signal / fault indication TXM1.8X-ML: As TXM1.8X, but with additional local override

More information

Manual LioN-P - IO-Link Device - I/O Hub

Manual LioN-P - IO-Link Device - I/O Hub Manual LioN-P - IO-Link Device - I/O Hub 0960 IOL 381-001 0960 IOL 385-001 0960 IOL 380-021 Technical Support support-automation@belden.com Contents Contents 1 About this Manual 6 1.1 General Information

More information

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1 Dimensions. 9.9 6 Model Number 6.7 Ref. 6. 5. 5.8 7 7.7.6 ø. 9 50 78.5 Receiver Emitter M x..7 sensor with -pin, M x connector Electrical connection Features Medium design with versatile mounting options

More information

CMC III Universal Sensor

CMC III Universal Sensor CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

Motor controllers CMMO-ST

Motor controllers CMMO-ST q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

Pressure sensors SPAN

Pressure sensors SPAN q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Pressure sensors SDE1, with display

Pressure sensors SDE1, with display Product range overview Method of measurement Piezoresistive pressure sensor with display Operating voltage Measured variable Pressure measuring range Pneumatic connection Type of mounting Electrical output

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

UM18-2 Pro Ultrasonic sensors OPERATING INSTRUCTIONS

UM18-2 Pro Ultrasonic sensors OPERATING INSTRUCTIONS UM18-2 Pro Ultrasonic sensors OPERATING INSTRUCTIONS Described product Manufacturer Legal information UM18-2 Pro SICK AG Erwin-Sick-Str. 1 79183 Waldkirch Germany This work is protected by copyright. Any

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

Operating instructions Pressure sensor. PE30xx / / 2010

Operating instructions Pressure sensor. PE30xx / / 2010 Operating instructions Pressure sensor PE30xx UK 704884 / 00 08 / 2010 Contents 1 Preliminary note3 1. ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 5 4.1 Processing of the

More information