FEATURES DESCRIPTION

Size: px
Start display at page:

Download "FEATURES DESCRIPTION"

Transcription

1 JUNCTION BOXES

2 FEATURES Allows easy and safe device connections to the fieldbus (Fo u n d at i o n fieldbus TM, PROFIBUS) HART and even for standard instrumentation wiring 4-20 ma; Ideal for coupling sensors, actuators and measuring instruments in safe and hazardous areas; Prevents short-circuiting to the entire bus during maintenance; Permits disconnecting one device without disrupting the bus; Reduces wiring costs as well as minimizes design costs of the process control system; Reduces stops, start-up time, and simplifies electrical maintenance; The weather proof housing prevents water, oil and dust from reaching the connections; 4 input/output connections used according to the application convenience; Easy internal bus terminator accommodation; The cables can be handled separately without interference from their wires; The bus trunk is separated from spurs, so any intervention in spurs not interferes in the operation of the trunk bus; Housing in aluminum or stainless steel. Cover gasket allows the use in watertight or wash-down applications; Locking mechanism; External grounding termina; Does not require lugs; Easy bus terminator accommodation Easy and safe connection DESCRIPTION The JM400 is a junction box especially designed for fieldbus and conventional instrumentation connections, for sensor and actuators connections. in case of device maintenance. This arrangement makes possible the disconnection of devices keeping the continuity of the whole bus, and also avoiding short-circuits. The IP66/68 rated enclosure combined with appropriate cable glands, protects the wire connections from dust, water and moisture. The IP66/68 rating matched with the adequate cable glands prevents water, oil, dust, and other mixtures from reaching the connections. It may be used indoors or outdoors and can withstand the most severe environments. The cover with internal threads allows an easy access to the terminals, without the use of special tools. The terminals are twin type at the four ends. They can be used as the input and output of the bus according to the application convenience, keeping apart the wires that should be disconnested 2

3 FIELDBUS OPTIMIZED THROUNGH JUNCTION BOXES Fieldbus presents several benefits, like cable reduction and installation flexibility. Several topologies can be used; the cable reduction will depend on the chosen topology. But what really happens when we build a Fo u n d at i o n fieldbus TM or PROFIBUS PA installation. Most installations will not benefit from this reduction, due to the use of conventional junction boxes that distributes wires to several field devices. When using conventional junction boxes, the topology used will most likely be the star topology. With this topology many devices will be derived from the same junction box, with each device requiring a pair of wires. Star Topology To really optimize cable amount a bus topology must be used. A true cost-effective bus topology can only be achieved using distributed junction boxes. Specially designed for Fieldbus topology JM400 improves the cable reduction allowing Fieldbus installations to reach their maximum savings and flexibility. These features make this type of junction box perfect for Fieldbus installations, reducing wiring and make easier maintenance. The installations used in conventional instrumentation also can be benefited by JM400 features. The JM400 junction boxes can be placed nearby the devices and do not require special supports to be mounted on. Bus Topology 3

4 TECHNICAL CHARACTERISTICS Functional Specifications Service Fieldbus (Fo u n d at i o n fieldbus TM, PROFIBUS), HART and conventional instrumentation wiring (4-20 ma), for sensor and actuators connections in safe and hazardous areas. C Hazardous Area Certification Certificate Nº: CEPEL- EX-0899/05X Explosion proof Ex d II C T T6 (-20 C < Tamb < 40 I=16 A; I= 23 A) T6 (-20 C < Tamb < 60 I=16 A) T5 (-20 C < Tamb < 40 I=23 A) T4 (-20 C < Tamb < 85 I=16 A; I= 23 A) Máx. Nominal Voltage: 750 V Máx. Nominal Current: 16 and 23 A Enclosure IP66/68 (Aluminum SAE 336 or A356) IP66/68W (AISI 316) Temperature Limits Ambient: -40 to 85 C (-40 to185 F). Humidity Limits 0-100% RH. Physical Specifications Electrical Connection ½ - 14 NPT, Pg 13,5 or M20 x 1,5 metirc. Rated Voltage: 750 V Rated Current: 23 A Housing Material Aluminum or stainless steel housing, saline environment included. Mounting Can be fixed on wall or panel. Weight Approximately 0.7 Kg (Aluminum) and 1.8 kg (Stainless Steel). ORDERING CODE JM400 FUNCTION BOXES COD. Electrical Connections 0 A B 1/2-14 NPT M20 x 1.5 Pg 13.5 DIN COD. H0 C H1 I H2 H3 Housing Material Aluminum Stainless Steel Aluminum for saline enviromenment Stainless Steel 316 for saline environment COD. Connections Types C1 C2 Spring* Screw JM400 A H0 C2 * Spring Connector (previous version) 4

5 ORDERING CODE Identification Plates I5 I6 IL Spare Parts CEPEL Centro de Pesquisas de Energia Elétrica Without Certification CEPEL: (Exd) + IP66/ Aluminum Cover Stainless Steel Cover Locking mechanism screw O-ring ¾ female NPT to ½ male NPT reduction sleeve, 316 SST Ex d ½ NPT internal hexagon plug, plated CS BR Ex d ½ NPT, internal hexagon plug, 304 SST BR Ex d M20 X 1.5 external hexagon plug, 316 SST BR Ex d PG 13.5 external hexagon plug, 316 SST BR Ex d ½ NPT internal hexagon plug, plated CS SAE ½ NPT internal hexagon plug, 304 SST GROUNDING The housing grounding must be done via ground screw, external, next to the identification plate. DIMENSIONS Dimensions are mm. 5

6 DIMENSIONS Mensagem smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: Copyright Smar International - all rights reserved. - September/2009 E 6

CURRENT TO PROFIBUS PA CONVERTER

CURRENT TO PROFIBUS PA CONVERTER PROFIBUS PA преобразователь тока в Profibus www.esma-rt.ru IF303 CURRENT TO PROFIBUS PA CONVERTER Features 0.03% accuracy. Three 4-20 ma input channels. Configuration and Parameterization all through configuring

More information

On-field visualization up to 8 variables received cyclically via PROFIBUS-DP master. Ideal for applications with any PROFIBUS-PA device

On-field visualization up to 8 variables received cyclically via PROFIBUS-DP master. Ideal for applications with any PROFIBUS-PA device On-field visualization up to 8 variables received cyclically via PROFIBUS-DP master Ideal for applications with any PROFIBUS-PA device Compatible with any PROFIBUS-DP class 1 master Easy-to-use compact

More information

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field Discrete I/O connected direct onto Profibus-PA Input and Output Function Blocks Two built-in Solid State Relay Outputs Discrete Function Blocks in the field Integrated I/O on the same hardware Two dry

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B Model Number Cable pull rotary encoder with PROFI- NET interface Features Robust aluminum drum housing Drum travel when cable retracted using threaded spindle Bellows with steel tip Comprehensive accessories

More information

Safety instructions Overvoltage protection B81-35

Safety instructions Overvoltage protection B81-35 Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application

More information

ProfiHub A5. 5 Channel DP Repeater

ProfiHub A5. 5 Channel DP Repeater ProfiHub A Channel DP Repeater The well-known ProfiHub A is a robust network component for PROFIBUS DP installations. It allows long multi-device spur lines and backbone structures with star/tree segments

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

PROFIBUS-DP/MODBUS RTU REPEATER

PROFIBUS-DP/MODBUS RTU REPEATER RP303 PROFIBUS-DP/MODBUS RTU REPEATER USER S MANUAL JAN/15 RP303 R P 3 0 3 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available

More information

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches TABLE OF CONTENTS IEC-309-1 and IEC-309- Pin and Sleeve Devices Introduction... - Material Specifications... 6-7 North American Ratings (0 to 100 Amp)... 8-16 Accessories... 17-18 International Ratings

More information

± 0.02% Accuracy Single Unit and Several Options for Sensors and Connections Input Signal Isolation Advanced Diagnostics Supported by DD, EDDL and

± 0.02% Accuracy Single Unit and Several Options for Sensors and Connections Input Signal Isolation Advanced Diagnostics Supported by DD, EDDL and ± 0.02% Accuracy Single Unit and Several Options for Sensors and Connections Input Signal Isolation Advanced Diagnostics Supported by DD, EDDL and FDT/D Sensor Backup SIL 2 Safety Certified to IEC 61508

More information

FieldLink process networking

FieldLink process networking FieldLink process networking Enclosures Junction module (JM) StoneL s Junction Module (JM) enclosure is an environmetally hardened platform which is suitable for use in the most extreme corrosive and hazardous

More information

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor.   Operating Instructions: EN. EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced

More information

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator Hazardous-Area 830 X R Loop-Powered 16 830 X S1 Loop-Powered 16 830 X S2 Loop-Powered 16 15 Loop-Powered Digital 830 X Loop-Powered 830 X R 830 X S1 830 X S2 The 830 X loop-powered digital indicators are

More information

Minimum cross sectional area of Conductor mm²

Minimum cross sectional area of Conductor mm² Selection Overview Hawke International connectors are ideal for use in hazardous areas commonly found in Oil and Gas exploration, production and process plants. Their features, however, also offer numerous

More information

FP300 Series. Available for both FOUNDATION fieldbus and PROFIBUS PA communication protocols. 3 to 15 psi or 3 to 30 psi output. Low air consumption

FP300 Series. Available for both FOUNDATION fieldbus and PROFIBUS PA communication protocols. 3 to 15 psi or 3 to 30 psi output. Low air consumption Available for both FOUNDATION fieldbus and PROFIBUS PA communication protocols 3 to 15 psi or 3 to 30 psi output Low air consumption Field calibration Auto diagnosis Extensive capacity for Function Blocks

More information

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field

More information

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX Connectors, Plugs & s Technical Datasheet Table of Contents Selection Guide 2 16A Range (ELCX 0251..) 3 32A Range (ELCX 0252..) 5 63A Range (ELCX 0253..) 7 125A Range (ELCX 0254..) 9 Elecex Ltd, Unit 9,

More information

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure Indication and Adjustment Product Information VEGADIS 61 Level Switching Pressure 2 VEGADIS 61 Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2 Principle of operation... 4 1.3 Adjustment...

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

4110 HART Level Encoder

4110 HART Level Encoder 4110 HART Level Encoder Precision encoding instrument for transmission of level measurement from mechanical float gauges Features Universal connection - mounts to all standard float gauges Low maintenance

More information

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

F101, F102, F104. Relcom  Installation Instructions. Fieldbus Power Supply F101-PS F101, F102, F104 Fieldbus Power Supply F101-PS Installation Instructions Relcom www.mtl-fieldbus.com CONTENTS PAGE 1 OVERVIEW 2 2 DESCRIPTION 2 3 COMPONENTS AND ACCESSORIES 2 4 MECHANICAL 3 4.1 Mounting

More information

SENSOR-ACTUATOR-INTEGRATOR (SAI) SERIES

SENSOR-ACTUATOR-INTEGRATOR (SAI) SERIES SAI Products SENSOR-ACTUATOR-INTEGRATOR (SAI) SERIES Industrial automation products (junction boxes) designed to be installed directly into your machine application Choice of metal or plastic housing protects

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

Explosion-Proof Gauge Pressure Transmitter

Explosion-Proof Gauge Pressure Transmitter Technology Solutions T EK-B AR 3120A Explosion-Proof Gauge Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

Technical Information Fieldgate SFG500

Technical Information Fieldgate SFG500 TI00029S/04/EN/10.16 71324508 Products Solutions Services Technical Information Fieldgate SFG500 Smart Ethernet/PROFIBUS gateway Parallel access to PROFIBUS networks Monitoring of PROFIBUS and HART device

More information

IEEE Mb/s single twisted pair Ethernet for Process Industry

IEEE Mb/s single twisted pair Ethernet for Process Industry IEEE 802.3 10 Mb/s single twisted pair Ethernet for Process Industry Harald Mueller, Markus Wucher, Dr. Joerg Haehniche Endress+Hauser Page 1 Purpose Scope Initiate discussion/understanding on typical

More information

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS Flexibility Data configuration with HART configurator Measuring of gauge and absolute pressure Reliability Continuous self-diagnostic

More information

Standard PROFINET IO. RoHS. High shaft load capacity. High protection level. Flexible

Standard PROFINET IO. RoHS. High shaft load capacity. High protection level. Flexible The encoders Sendix 5868 and 5888 with PROFINET interface and optical sensor technology are ideal for use in all applications with PROFINET technology. The encoder supports the isochronous (IRT) mode and

More information

Distributed Intrinsically Safe Fieldbus Applications

Distributed Intrinsically Safe Fieldbus Applications Application Note FB01-1 - Distributed Intrinsically Safe Fieldbus Applications Emerson Process Management DeltaV DCS System Pepperl+Fuchs June 2003 Application Note FB01-2 - c Pepperl+Fuchs Inc. All rights

More information

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012 ERNG-X DERNG2108X012 Description The ERNG-X is a steady state no bleed engineered system for accurate and reliable control of Natural Gas. The ERNG-X includes a pressure regulator, preconditioning filters,

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

RT2Y Compact temperature switch intrinsic safety

RT2Y Compact temperature switch intrinsic safety ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications

More information

Temperature process values at a glance

Temperature process values at a glance Temperature process values at a glance PERFORMANCE MADE SMARTER COMMUNIC AT I ON F OUND AT I O N TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY 7501 Field mounted

More information

JM - Junction Enclosure Modules for Communication Networks

JM - Junction Enclosure Modules for Communication Networks Pub #110014revB, Part 1-12/2002 JM - Junction Enclosure Modules for Communication etworks Installation & Adjusting Instructions for JMT, JMP, JMS, JMD, JMB series The JM provides a watertight / explosion

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 5868 and 5888 with interface and optical sensor technology are ideal for use in all applications with a interface. The encoder supports the isochronous (IRT) mode and is therefore

More information

InCos-P Pressure sensor 20 Pa Pa

InCos-P Pressure sensor 20 Pa Pa InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.

More information

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability oo Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil housing > > International approvals > > Stainless

More information

Safety Instructions Cerabar S PMP71, PMP75

Safety Instructions Cerabar S PMP71, PMP75 /00/EN/01.14 71249311 Products Solutions Services Safety Instructions PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex d IIC T* Gb TÜV 13.0902X Segurança TÜV INMETRO OCP 0004 Document: Safety

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

FOSTEN AUTOMATION SÉRIE F500-A

FOSTEN AUTOMATION SÉRIE F500-A FOSTEN AUTOMATION SÉRIE F500-A Absolute Pressure Capacitive Transmitter Absolute Pressure Capacitive Transmitter Low maintenance, quick calibration and configuration. Installation directly into pressurized

More information

selos The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail

selos The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail selos DIN rail terminal blocks with screw connection Reliable connection, proven concept!

More information

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX OUR COMPONENTS... CONFIGURABLE TO YOUR NEEDS No application is like the others; every application always

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process

More information

RT2E Compact temperature switch Explosion proof

RT2E Compact temperature switch Explosion proof ompact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2,

More information

USB INTERFACE FOR PROFIBUS PA

USB INTERFACE FOR PROFIBUS PA USER MANUAL USB INTERFACE FOR PROFIBUS PA MAR / 12 PBI-PLUS P B I P L U S M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available

More information

OPERATION AND MAINTENANCE, INSTRUCTION MANUAL. PROFIBUS-PA Remote Indicator

OPERATION AND MAINTENANCE, INSTRUCTION MANUAL. PROFIBUS-PA Remote Indicator OPERATION AND MAINTENANCE, INSTRUCTION MANUAL PROFIBUS-PA Remote Indicator I R 3 0 3 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2 > For use in hazardous areas with gas group IIB+H 2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Instruction Manual. T3110 T3110L T3110Ex

Instruction Manual. T3110 T3110L T3110Ex www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,

More information

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based

More information

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485 www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10 Model Number Features Solid shaft 0 Bit multiturn Free of wear magnetic sampling High resolution and accuracy Mechanical compatibility with all major encoders with fieldbus interface Status LEDs Description

More information

KOBOLD TDA Series Digital Temperature Transmitter

KOBOLD TDA Series Digital Temperature Transmitter KOBOLD TDA Series Digital Temperature Transmitter TDA-15 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com

More information

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.

More information

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...) 7 818 Actuators SQM9... Electromotoric actuators Torques up to 60 Nm Running times ¹) 30...120 s ¹) Predefined by the basic unit (LMV5...) The SQM9... and this Data Sheet are intended for use by OEMs which

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Discrete I/O connected direct onto. Input and Output Function Blocks, including Flexible Function Block (FFB) for logic execution

Discrete I/O connected direct onto. Input and Output Function Blocks, including Flexible Function Block (FFB) for logic execution Discrete I/O connected direct onto Profibus-PA Input and Output Function Blocks, including Flexible Function Block (FFB) for logic execution Power, Control and I/O integrated in the same hardware Mix Profibus

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate : IECEx PTB 04.0005 http://iecex.iec.ch/iecex/iecexweb.nsf/certificatesajax/iecex%20ptb%2004.0005%... Seite 1 von 4 10.01.2013 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme

More information

Thermocouples Model TC200, for Additional Thermowell

Thermocouples Model TC200, for Additional Thermowell Electrical Temperature Measurement Thermocouples Model TC200, for Additional Thermowell WIKA Data Sheet TE 65.10 Applications T Machinery, plant and tank construction T Energy and power plant technology

More information

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

smar   Specifications and information are subject to change without notice. Up-to-date address information is available on our website. smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp Introduction INTRODUCTION

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS THERMOWELL & REPLACEABLE GENERAL PURPOSE PT100CB/TP C20 C21 C24 C26-1 1 C26-2 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded

More information

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485 www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with

More information

4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection 4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection Product ID: ICUSB234854I Add four extra COM ports to your laptop or desktop computer, quickly and easily. This USB to RS232/422/485

More information

Spare Parts for RM71 SmartLine Guided Radar Level Meter

Spare Parts for RM71 SmartLine Guided Radar Level Meter Spare Parts f RM71 SmartLine Guided Radar Level Meter XM71 All but 2mm F 2mm probe style see MSG 36-RM-16-06 (XM72) 36-RM-16U-05 Page 1 of 8 Model Selection Guide Supply the iginal instrument model code

More information

EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS

EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS Table of Contents EFP Introduction 4 Connector Features 5-7 Code Logic 8 Inline Plug w Threaded Entry Metric 9 Inline Plug w Mechanical

More information

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description Block device couplers Data sheet 3177_en_A 1 Description PHOENX CONTACT 2015-01-20 2 Features The and block couplers provide an interface between the fieldbus trunk cable and field devices on Foundation

More information

gesis IP+ Installation System in IP IP 68 For use in rough environments Excerpt from the product range MC 04/07

gesis IP+ Installation System in IP IP 68 For use in rough environments Excerpt from the product range MC 04/07 gesis IP+ Installation System in IP 6... IP 68 For use in rough environments Excerpt from the product range 0162.6 MC 04/07 Areas gesis IP+ For electrical installations with increased requirements for

More information

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed. 2 The integrates position sensing, communication electronics, power outputs, auxiliary inputs and wire termination into a fully sealed compact package. The module also integrates a terminal strip directly

More information

Available for the communication protocols: 4 to 20 ma, HART, FOUNDATION fieldbus and PROFIBUS PA Automatic Setup Single Action or Double Action

Available for the communication protocols: 4 to 20 ma, HART, FOUNDATION fieldbus and PROFIBUS PA Automatic Setup Single Action or Double Action Available for the communication protocols: 4 to 20 ma, HART, FOUNDATION fieldbus and PROFIBUS PA Automatic Setup Single Action or Double Action Non-contact position measurement Valve position reading from

More information

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7 90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators

More information

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview Application The connects wireless HART field devices by radio to the Ethernet. On the radio side, the supports the WirelessHART standard and on the Ethernet side the TCP/IP and Modbus TCP communication.

More information

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM 10-Port Industrial USB 3.0 Hub - ESD and Surge Protection StarTech ID: ST1030USBM This 10-port USB 3.0 hub gives you the scalability you need in harsh industrial environments. It s designed to meet the

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

ArmorConnect Power and Control Media

ArmorConnect Power and Control Media Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with

More information

CLIPLINE complete. The modular terminal block system for all applications

CLIPLINE complete. The modular terminal block system for all applications CLIPLINE complete The modular terminal block system for all applications CLIPLINE complete All connection technologies, one system With CLIPLINE complete, the unique modular terminal block system from

More information

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof 757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Level measurement CleverLevel LBFI Point level detection

Level measurement CleverLevel LBFI Point level detection Product highlights User benefi ts Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status

More information

Level measurement CleverLevel LBFI Point level detection

Level measurement CleverLevel LBFI Point level detection User Product benefits highlights Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status

More information

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors

More information

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications New Product Bulletin PB 327 Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications These 16 digital I/O channels with universal input/output functionality for direct connections

More information

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

smar  Specifications and information are subject to change without notice. Up-to-date address information is available on our website. T P 3 0 1 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp INTRODUCTION

More information

IHP24. Intelligent Hydraulic Positioner D HP- PL

IHP24. Intelligent Hydraulic Positioner D HP- PL IHP24 Intelligent Hydraulic Positioner D HP- PL- 0 0 3-01 IHP24 Intelligent Hydraulic Positioner Val Controls A/S Intelligent valve control based on the latest know-how concerning digital technology for

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information