1 JUNCTION BOXES
2 FEATURES Allows easy and safe device connections to the fieldbus (Fo u n d at i o n fieldbus TM, PROFIBUS) HART and even for standard instrumentation wiring 4-20 ma; Ideal for coupling sensors, actuators and measuring instruments in safe and hazardous areas; Prevents short-circuiting to the entire bus during maintenance; Permits disconnecting one device without disrupting the bus; Reduces wiring costs as well as minimizes design costs of the process control system; Reduces stops, start-up time, and simplifies electrical maintenance; The weather proof housing prevents water, oil and dust from reaching the connections; 4 input/output connections used according to the application convenience; Easy internal bus terminator accommodation; The cables can be handled separately without interference from their wires; The bus trunk is separated from spurs, so any intervention in spurs not interferes in the operation of the trunk bus; Housing in aluminum or stainless steel. Cover gasket allows the use in watertight or wash-down applications; Locking mechanism; External grounding termina; Does not require lugs; Easy bus terminator accommodation Easy and safe connection DESCRIPTION The JM400 is a junction box especially designed for fieldbus and conventional instrumentation connections, for sensor and actuators connections. in case of device maintenance. This arrangement makes possible the disconnection of devices keeping the continuity of the whole bus, and also avoiding short-circuits. The IP66/68 rated enclosure combined with appropriate cable glands, protects the wire connections from dust, water and moisture. The IP66/68 rating matched with the adequate cable glands prevents water, oil, dust, and other mixtures from reaching the connections. It may be used indoors or outdoors and can withstand the most severe environments. The cover with internal threads allows an easy access to the terminals, without the use of special tools. The terminals are twin type at the four ends. They can be used as the input and output of the bus according to the application convenience, keeping apart the wires that should be disconnested 2
3 FIELDBUS OPTIMIZED THROUNGH JUNCTION BOXES Fieldbus presents several benefits, like cable reduction and installation flexibility. Several topologies can be used; the cable reduction will depend on the chosen topology. But what really happens when we build a Fo u n d at i o n fieldbus TM or PROFIBUS PA installation. Most installations will not benefit from this reduction, due to the use of conventional junction boxes that distributes wires to several field devices. When using conventional junction boxes, the topology used will most likely be the star topology. With this topology many devices will be derived from the same junction box, with each device requiring a pair of wires. Star Topology To really optimize cable amount a bus topology must be used. A true cost-effective bus topology can only be achieved using distributed junction boxes. Specially designed for Fieldbus topology JM400 improves the cable reduction allowing Fieldbus installations to reach their maximum savings and flexibility. These features make this type of junction box perfect for Fieldbus installations, reducing wiring and make easier maintenance. The installations used in conventional instrumentation also can be benefited by JM400 features. The JM400 junction boxes can be placed nearby the devices and do not require special supports to be mounted on. Bus Topology 3
4 TECHNICAL CHARACTERISTICS Functional Specifications Service Fieldbus (Fo u n d at i o n fieldbus TM, PROFIBUS), HART and conventional instrumentation wiring (4-20 ma), for sensor and actuators connections in safe and hazardous areas. C Hazardous Area Certification Certificate Nº: CEPEL- EX-0899/05X Explosion proof Ex d II C T T6 (-20 C < Tamb < 40 I=16 A; I= 23 A) T6 (-20 C < Tamb < 60 I=16 A) T5 (-20 C < Tamb < 40 I=23 A) T4 (-20 C < Tamb < 85 I=16 A; I= 23 A) Máx. Nominal Voltage: 750 V Máx. Nominal Current: 16 and 23 A Enclosure IP66/68 (Aluminum SAE 336 or A356) IP66/68W (AISI 316) Temperature Limits Ambient: -40 to 85 C (-40 to185 F). Humidity Limits 0-100% RH. Physical Specifications Electrical Connection ½ - 14 NPT, Pg 13,5 or M20 x 1,5 metirc. Rated Voltage: 750 V Rated Current: 23 A Housing Material Aluminum or stainless steel housing, saline environment included. Mounting Can be fixed on wall or panel. Weight Approximately 0.7 Kg (Aluminum) and 1.8 kg (Stainless Steel). ORDERING CODE JM400 FUNCTION BOXES COD. Electrical Connections 0 A B 1/2-14 NPT M20 x 1.5 Pg 13.5 DIN COD. H0 C H1 I H2 H3 Housing Material Aluminum Stainless Steel Aluminum for saline enviromenment Stainless Steel 316 for saline environment COD. Connections Types C1 C2 Spring* Screw JM400 A H0 C2 * Spring Connector (previous version) 4
5 ORDERING CODE Identification Plates I5 I6 IL Spare Parts CEPEL Centro de Pesquisas de Energia Elétrica Without Certification CEPEL: (Exd) + IP66/ Aluminum Cover Stainless Steel Cover Locking mechanism screw O-ring ¾ female NPT to ½ male NPT reduction sleeve, 316 SST Ex d ½ NPT internal hexagon plug, plated CS BR Ex d ½ NPT, internal hexagon plug, 304 SST BR Ex d M20 X 1.5 external hexagon plug, 316 SST BR Ex d PG 13.5 external hexagon plug, 316 SST BR Ex d ½ NPT internal hexagon plug, plated CS SAE ½ NPT internal hexagon plug, 304 SST GROUNDING The housing grounding must be done via ground screw, external, next to the identification plate. DIMENSIONS Dimensions are mm. 5
6 DIMENSIONS Mensagem smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: Copyright Smar International - all rights reserved. - September/2009 E 6
CURRENT TO PROFIBUS PA CONVERTER
PROFIBUS PA преобразователь тока в Profibus www.esma-rt.ru IF303 CURRENT TO PROFIBUS PA CONVERTER Features 0.03% accuracy. Three 4-20 ma input channels. Configuration and Parameterization all through configuring
More informationOn-field visualization up to 8 variables received cyclically via PROFIBUS-DP master. Ideal for applications with any PROFIBUS-PA device
On-field visualization up to 8 variables received cyclically via PROFIBUS-DP master Ideal for applications with any PROFIBUS-PA device Compatible with any PROFIBUS-DP class 1 master Easy-to-use compact
More informationDiscrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field
Discrete I/O connected direct onto Profibus-PA Input and Output Function Blocks Two built-in Solid State Relay Outputs Discrete Function Blocks in the field Integrated I/O on the same hardware Two dry
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationTFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5
EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on
More informationTechnical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B
Model Number Cable pull rotary encoder with PROFI- NET interface Features Robust aluminum drum housing Drum travel when cable retracted using threaded spindle Bellows with steel tip Comprehensive accessories
More informationSafety instructions Overvoltage protection B81-35
Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application
More informationProfiHub A5. 5 Channel DP Repeater
ProfiHub A Channel DP Repeater The well-known ProfiHub A is a robust network component for PROFIBUS DP installations. It allows long multi-device spur lines and backbone structures with star/tree segments
More informationOperating Instructions
Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on
More informationPROFIBUS-DP/MODBUS RTU REPEATER
RP303 PROFIBUS-DP/MODBUS RTU REPEATER USER S MANUAL JAN/15 RP303 R P 3 0 3 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available
More informationTABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches
TABLE OF CONTENTS IEC-309-1 and IEC-309- Pin and Sleeve Devices Introduction... - Material Specifications... 6-7 North American Ratings (0 to 100 Amp)... 8-16 Accessories... 17-18 International Ratings
More information± 0.02% Accuracy Single Unit and Several Options for Sensors and Connections Input Signal Isolation Advanced Diagnostics Supported by DD, EDDL and
± 0.02% Accuracy Single Unit and Several Options for Sensors and Connections Input Signal Isolation Advanced Diagnostics Supported by DD, EDDL and FDT/D Sensor Backup SIL 2 Safety Certified to IEC 61508
More informationFieldLink process networking
FieldLink process networking Enclosures Junction module (JM) StoneL s Junction Module (JM) enclosure is an environmetally hardened platform which is suitable for use in the most extreme corrosive and hazardous
More informationCombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.
EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced
More informationIndicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator
Hazardous-Area 830 X R Loop-Powered 16 830 X S1 Loop-Powered 16 830 X S2 Loop-Powered 16 15 Loop-Powered Digital 830 X Loop-Powered 830 X R 830 X S1 830 X S2 The 830 X loop-powered digital indicators are
More informationMinimum cross sectional area of Conductor mm²
Selection Overview Hawke International connectors are ideal for use in hazardous areas commonly found in Oil and Gas exploration, production and process plants. Their features, however, also offer numerous
More informationFP300 Series. Available for both FOUNDATION fieldbus and PROFIBUS PA communication protocols. 3 to 15 psi or 3 to 30 psi output. Low air consumption
Available for both FOUNDATION fieldbus and PROFIBUS PA communication protocols 3 to 15 psi or 3 to 30 psi output Low air consumption Field calibration Auto diagnosis Extensive capacity for Function Blocks
More informationFieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)
Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field
More informationTechnical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX
Connectors, Plugs & s Technical Datasheet Table of Contents Selection Guide 2 16A Range (ELCX 0251..) 3 32A Range (ELCX 0252..) 5 63A Range (ELCX 0253..) 7 125A Range (ELCX 0254..) 9 Elecex Ltd, Unit 9,
More informationIndication and Adjustment Product Information VEGADIS 61. Level Switching Pressure
Indication and Adjustment Product Information VEGADIS 61 Level Switching Pressure 2 VEGADIS 61 Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2 Principle of operation... 4 1.3 Adjustment...
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof
More information4110 HART Level Encoder
4110 HART Level Encoder Precision encoding instrument for transmission of level measurement from mechanical float gauges Features Universal connection - mounts to all standard float gauges Low maintenance
More informationF101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS
F101, F102, F104 Fieldbus Power Supply F101-PS Installation Instructions Relcom www.mtl-fieldbus.com CONTENTS PAGE 1 OVERVIEW 2 2 DESCRIPTION 2 3 COMPONENTS AND ACCESSORIES 2 4 MECHANICAL 3 4.1 Mounting
More informationSENSOR-ACTUATOR-INTEGRATOR (SAI) SERIES
SAI Products SENSOR-ACTUATOR-INTEGRATOR (SAI) SERIES Industrial automation products (junction boxes) designed to be installed directly into your machine application Choice of metal or plastic housing protects
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationTechnical Information Promonitor NRF560
TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo
More informationExplosion-Proof Gauge Pressure Transmitter
Technology Solutions T EK-B AR 3120A Explosion-Proof Gauge Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar
More informationMechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems
Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the
More informationTechnical Information Fieldgate SFG500
TI00029S/04/EN/10.16 71324508 Products Solutions Services Technical Information Fieldgate SFG500 Smart Ethernet/PROFIBUS gateway Parallel access to PROFIBUS networks Monitoring of PROFIBUS and HART device
More informationIEEE Mb/s single twisted pair Ethernet for Process Industry
IEEE 802.3 10 Mb/s single twisted pair Ethernet for Process Industry Harald Mueller, Markus Wucher, Dr. Joerg Haehniche Endress+Hauser Page 1 Purpose Scope Initiate discussion/understanding on typical
More informationTRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS
TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS Flexibility Data configuration with HART configurator Measuring of gauge and absolute pressure Reliability Continuous self-diagnostic
More informationStandard PROFINET IO. RoHS. High shaft load capacity. High protection level. Flexible
The encoders Sendix 5868 and 5888 with PROFINET interface and optical sensor technology are ideal for use in all applications with PROFINET technology. The encoder supports the isochronous (IRT) mode and
More informationDistributed Intrinsically Safe Fieldbus Applications
Application Note FB01-1 - Distributed Intrinsically Safe Fieldbus Applications Emerson Process Management DeltaV DCS System Pepperl+Fuchs June 2003 Application Note FB01-2 - c Pepperl+Fuchs Inc. All rights
More informationERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012
ERNG-X DERNG2108X012 Description The ERNG-X is a steady state no bleed engineered system for accurate and reliable control of Natural Gas. The ERNG-X includes a pressure regulator, preconditioning filters,
More informationFlow Measurement SITRANS F US Inline
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationFlow Measurement SITRANS F US Inline
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationRT2Y Compact temperature switch intrinsic safety
ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications
More informationTemperature process values at a glance
Temperature process values at a glance PERFORMANCE MADE SMARTER COMMUNIC AT I ON F OUND AT I O N TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY 7501 Field mounted
More informationJM - Junction Enclosure Modules for Communication Networks
Pub #110014revB, Part 1-12/2002 JM - Junction Enclosure Modules for Communication etworks Installation & Adjusting Instructions for JMT, JMP, JMS, JMD, JMB series The JM provides a watertight / explosion
More informationEmergency Luminaire for Fluorescent Lamps Series EXLUX 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationAbsolute Encoders Multiturn
The multiturn encoders 5868 and 5888 with interface and optical sensor technology are ideal for use in all applications with a interface. The encoder supports the isochronous (IRT) mode and is therefore
More informationInCos-P Pressure sensor 20 Pa Pa
InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.
More informationV88 series Redundant valve manifold systems - Semi modular 2oo2 Availability
oo Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil housing > > International approvals > > Stainless
More informationSafety Instructions Cerabar S PMP71, PMP75
/00/EN/01.14 71249311 Products Solutions Services Safety Instructions PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex d IIC T* Gb TÜV 13.0902X Segurança TÜV INMETRO OCP 0004 Document: Safety
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More informationFOSTEN AUTOMATION SÉRIE F500-A
FOSTEN AUTOMATION SÉRIE F500-A Absolute Pressure Capacitive Transmitter Absolute Pressure Capacitive Transmitter Low maintenance, quick calibration and configuration. Installation directly into pressurized
More informationselos The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail
The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail selos DIN rail terminal blocks with screw connection Reliable connection, proven concept!
More informationPROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX
PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX OUR COMPONENTS... CONFIGURABLE TO YOUR NEEDS No application is like the others; every application always
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationEngineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O
Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process
More informationRT2E Compact temperature switch Explosion proof
ompact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2,
More informationUSB INTERFACE FOR PROFIBUS PA
USER MANUAL USB INTERFACE FOR PROFIBUS PA MAR / 12 PBI-PLUS P B I P L U S M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available
More informationOPERATION AND MAINTENANCE, INSTRUCTION MANUAL. PROFIBUS-PA Remote Indicator
OPERATION AND MAINTENANCE, INSTRUCTION MANUAL PROFIBUS-PA Remote Indicator I R 3 0 3 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationLinear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2
> For use in hazardous areas with gas group IIB+H 2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationInstruction Manual. T3110 T3110L T3110Ex
www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,
More information3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based
More informationVALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationGrounding Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationTechnical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10
Model Number Features Solid shaft 0 Bit multiturn Free of wear magnetic sampling High resolution and accuracy Mechanical compatibility with all major encoders with fieldbus interface Status LEDs Description
More informationKOBOLD TDA Series Digital Temperature Transmitter
KOBOLD TDA Series Digital Temperature Transmitter TDA-15 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com
More informationProduct Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11
Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.
More informationElectromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)
7 818 Actuators SQM9... Electromotoric actuators Torques up to 60 Nm Running times ¹) 30...120 s ¹) Predefined by the basic unit (LMV5...) The SQM9... and this Data Sheet are intended for use by OEMs which
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99
More informationDiscrete I/O connected direct onto. Input and Output Function Blocks, including Flexible Function Block (FFB) for logic execution
Discrete I/O connected direct onto Profibus-PA Input and Output Function Blocks, including Flexible Function Block (FFB) for logic execution Power, Control and I/O integrated in the same hardware Mix Profibus
More informationIECEx Certificate of Conformity
Certificate : IECEx PTB 04.0005 http://iecex.iec.ch/iecex/iecexweb.nsf/certificatesajax/iecex%20ptb%2004.0005%... Seite 1 von 4 10.01.2013 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme
More informationThermocouples Model TC200, for Additional Thermowell
Electrical Temperature Measurement Thermocouples Model TC200, for Additional Thermowell WIKA Data Sheet TE 65.10 Applications T Machinery, plant and tank construction T Energy and power plant technology
More informationsmar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.
smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp Introduction INTRODUCTION
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More informationSUBCON-PLUS-PROFIB...
Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationPROFIBUS-PA Positioner Type 3785
PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,
More informationSPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS
SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS THERMOWELL & REPLACEABLE GENERAL PURPOSE PT100CB/TP C20 C21 C24 C26-1 1 C26-2 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded
More informationGrounding Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More information4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection
4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection Product ID: ICUSB234854I Add four extra COM ports to your laptop or desktop computer, quickly and easily. This USB to RS232/422/485
More informationSpare Parts for RM71 SmartLine Guided Radar Level Meter
Spare Parts f RM71 SmartLine Guided Radar Level Meter XM71 All but 2mm F 2mm probe style see MSG 36-RM-16-06 (XM72) 36-RM-16U-05 Page 1 of 8 Model Selection Guide Supply the iginal instrument model code
More informationEFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS
EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS Table of Contents EFP Introduction 4 Connector Features 5-7 Code Logic 8 Inline Plug w Threaded Entry Metric 9 Inline Plug w Mechanical
More informationFB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description
Block device couplers Data sheet 3177_en_A 1 Description PHOENX CONTACT 2015-01-20 2 Features The and block couplers provide an interface between the fieldbus trunk cable and field devices on Foundation
More informationgesis IP+ Installation System in IP IP 68 For use in rough environments Excerpt from the product range MC 04/07
gesis IP+ Installation System in IP 6... IP 68 For use in rough environments Excerpt from the product range 0162.6 MC 04/07 Areas gesis IP+ For electrical installations with increased requirements for
More informationDual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.
2 The integrates position sensing, communication electronics, power outputs, auxiliary inputs and wire termination into a fully sealed compact package. The module also integrates a terminal strip directly
More informationAvailable for the communication protocols: 4 to 20 ma, HART, FOUNDATION fieldbus and PROFIBUS PA Automatic Setup Single Action or Double Action
Available for the communication protocols: 4 to 20 ma, HART, FOUNDATION fieldbus and PROFIBUS PA Automatic Setup Single Action or Double Action Non-contact position measurement Valve position reading from
More information97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7
90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators
More informationExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)
Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC
More informationSupplementary Components WirelessHART products
Overview Application The connects wireless HART field devices by radio to the Ethernet. On the radio side, the supports the WirelessHART standard and on the Ethernet side the TCP/IP and Modbus TCP communication.
More information10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM
10-Port Industrial USB 3.0 Hub - ESD and Surge Protection StarTech ID: ST1030USBM This 10-port USB 3.0 hub gives you the scalability you need in harsh industrial environments. It s designed to meet the
More informationOperating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern
Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents
More informationArmorConnect Power and Control Media
Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with
More informationCLIPLINE complete. The modular terminal block system for all applications
CLIPLINE complete The modular terminal block system for all applications CLIPLINE complete All connection technologies, one system With CLIPLINE complete, the unique modular terminal block system from
More informationCable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof
757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP
More informationFieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway
Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety
More informationLevel measurement CleverLevel LBFI Point level detection
Product highlights User benefi ts Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status
More informationLevel measurement CleverLevel LBFI Point level detection
User Product benefits highlights Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status
More informationDIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi
V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors
More informationNew Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications
New Product Bulletin PB 327 Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications These 16 digital I/O channels with universal input/output functionality for direct connections
More informationsmar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.
T P 3 0 1 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp INTRODUCTION
More informationIHP24. Intelligent Hydraulic Positioner D HP- PL
IHP24 Intelligent Hydraulic Positioner D HP- PL- 0 0 3-01 IHP24 Intelligent Hydraulic Positioner Val Controls A/S Intelligent valve control based on the latest know-how concerning digital technology for
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More information