PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

Size: px
Start display at page:

Download "PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX"

Transcription

1 PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

2 OUR COMPONENTS... CONFIGURABLE TO YOUR NEEDS No application is like the others; every application always places new requirements on the properties and configuration of a fieldbus junction box. We bear witness to this fact with the new modular Field Junction Box System for our familiar FieldConnex products. Besides the housing size, you can customize your Field Junction Box to your own personal needs, from the cable glands to the electronics to overvoltage protection. Besides a custom-fit solution for your application, the Field Junction Box allows the fastest possible installation on location, reducing engineering costs at the same time. STAINLESS STEEL HOUSING SS36L/.444 ELECTRONICS S 28 mm x 7 mm x mm Protection class IP68/Type 6-5 C + 8 C Field barrier RD-FB-EX4 Connection of highest number of intrinsically safe field devices to a modern field bus Installation in Zone /Class I, Div. 2 Galvanic isolation and overload protection at the spur Reduced wiring S2 3 mm x 2 mm x 2 mm Protection class IP68-5 C +8 C Segment Protector R-JBSC- / R-SP-N Connection of field devices to modern fieldbus Installation in Zone 2/Class I, Div. 2 Increased reliability due to protection from short-circuits and overload Fast, efficient fault finding and correction using LED display S2 377 mm x 377 mm x 6 mm Protection class IP68-5 C +8 C S3 48 mm x 4 mm x 6 mm Protection class IP68-5 C +8 C Temperature Multi-input RD-TI-EX8.FF.ST Efficient integration of eight different analogue signals into the fieldbus communications Intrinsic safety: Installation in Zone /Class I, Div. High flexibility, large selection of sensors can be connected Reliable systems operation due to continuous monitoring of sensors and connection lines Excellent data quality due to potential isolation of inputs and very short update cycles Valve coupler FD-VC-EX4.FF Efficient control of four solenoid valves with end position sensing via one fieldbus address Intrinsic safety: Installation in Zone /Class I, Div. Line break and short-circuit monitoring of inputs and outputs Power supply through the fieldbus cable

3 Ex-tested installation solutions for fieldbus in zones /2/2/22 and Div. /Div. 2 Customer-oriented availability Customer- and industry-specific solutions for fieldbus distribution (non-ex, too) CABLE GLANDS TERMINALS Dummy plugs M2 M2 cable gland, plastic Screw terminal EEx e II G D,2 mm 2 4 mm 2, 24 AWG AWG M2 cable gland Nickel-plated brass M2 cable gland Stainless steel Screw terminal with disconnector EEx ia,2 mm 2 2,5 mm 2, 24 AWG 2 AWG M2 cable gland for reinforced cable, brass, nickel-plated M2 cable gland for reinforced cable, Stainless steel Spring terminal EEx e II G D,2 mm 2 2,5 mm 2, 24 AWG 2 AWG Plug connector 7/8", Nickel-plated brass EEx e II GD Plastic IP66/Type 4X UL certificate -3 C +7 C Metal IP68/Type 6 UL certificate -4 C +8 C Spring terminal with blade insulation terminal EEx ia,8 mm 2 2,5 mm 2, 28 AWG 2 AWG

4 OVERVOLTAGE PROTECTION TERMINAL RESISTANCE DB-LB-I/DP-LBF-I According to FISCO or Entity Installation in Zone Two-part structure, base module DB-LB-I is mounted on DIN rail and serves as socket for the protection module DP-LBF-I KMD-FT-E Bus terminator for installation on DIN rails Reliable fieldbus communications by damping line reflections According to FISCO and Entity Field Junction Box the trusted F2 aluminium housing Field Junction Box also available in polyester (GRP) housing

5 TYPE KEY FOR TECHNICAL INFORMATION FAMILY F B S P... T I V C Field barrier RD-FB-EX4 Segment Protector R-JBSC- / R-SP-N Temperature Multi-input RD-TI-EX8.FF.ST Valve coupler FD-VC-EX4.FF HOUSING TYPES S P EX CERTIFICATE 7 Stainless steel SS36L/.444 Polyester (GRP) Certificate NUMBER OF CHANNELS channels 6 channels 8 channels channels 2 channels 6 channels 24 channels 32 channels FIELDBUS F P TERMINALS 3 5 GLANDS & CONNECTIONS H H 2 H C G P 2 G B 2 G S 2 G N 2 G A 2 G C V 9 ACCESSORIES Foundation Fieldbus H + Profibus PA Foundation Fieldbus H Profibus PA No terminals Screw terminals Spring terminals Customer version Boring 2.5 mm Blind plugs M2 Hole for special diameter M2 cable gland, plastic M2 cable gland, nickel-plated brass M2 cable gland, stainless steel M2 cable gland for reinforced cable, nickel-plated brass M2 cable gland for reinforced cable, stainless steel Customer specified Plug connector 7/8", nickel-plated brass A B 2 3 T No plate for labelling Plastic plate for labelling, 2mm x 4mm Stainless steel plate for labelling, 2mm x 4mm Without grounding bar With grounding bar No overvoltage protection Overvoltage protection on spurs and trunk Overvoltage protection on spurs Overvoltage protection on trunk No terminating resistance Terminating resistance

6 TECHNICAL DATA VARIANT STAINLESS STEEL HOUSING General housing features SS36L/.444 high-gloss polish Condensate drain / ventilation M grounding screws Mounting brackets Door hinges DIN rail Variant with plastic gland Variant with metal gland Protection class IP66 per EN 6529/NEMA 4X IP68 per EN 6529/NEMA 6 Operating temperature 3 C +7 C 4 C +7 C Storage temperature 4 C +8 C 4 C +8 C Climatic conditions compliant with DIN IEC 72 DIN IEC 72 Shock resistance 7 Nm per EN 54 7 Nm per EN 54 Approvals In process In process Worldwide Headquarters Pepperl+Fuchs GmbH 6837 Mannheim Germany Tel info@de.pepperl-fuchs.com USA Headquarters Pepperl+Fuchs Inc. Twinsburg, Ohio 4487 USA Tel sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Singapore Company Registration No.9933E Tel sales@sg.pepperl-fuchs.com Subject to reasonable modifications due to technical advances Copyright PEPPERL+FUCHS Printed in Germany Part. No /6

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

PROCESS AUTOMATION. Installation Technology for FOUNDATION Fieldbus

PROCESS AUTOMATION. Installation Technology for FOUNDATION Fieldbus PROCESS AUTOMATION Installation Technology for FOUNDATION Fieldbus HOST Plant Communication with Fieldbus page 4 Benefit from the future proof, enabling technology page 10 Power Supply Power your field

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

FACTORY AUTOMATION. CONFIGURATION INSTRUCTIONS WCS3B-LS*** with RS485 interface

FACTORY AUTOMATION. CONFIGURATION INSTRUCTIONS WCS3B-LS*** with RS485 interface FACTORY AUTOMATION CONFIGURATION INSTRUCTIONS WCS3B-LS*** with RS485 interface Part. No. xxxxxx / DOCT-1277 / 2007/04/24 1 Configuration switches in the reading head (Base types)4 1.1 General..........................................

More information

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs Andreas Agostin Pepperl+Fuchs Abstract InfraServ Hoechst and Aventis Pharma of Germany performed a comparison study

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field

More information

PROCESS AUTOMATION INSTALLATION TECHNOLOGY FOR PROFIBUS PA

PROCESS AUTOMATION INSTALLATION TECHNOLOGY FOR PROFIBUS PA PROCESS AUTOMATION INSTALLATION TECHNOLOGY FOR PROFIBUS PA SYSTEM OVERVIEW AND CONTENT HOST Plant Communication page 4 with Fieldbus Benefit from the future proof, enabling technology page 12 Segment coupler

More information

Trusted Strategic Partners in Process Automation. Alliance Member

Trusted Strategic Partners in Process Automation. Alliance Member Trusted Strategic Partners in Process Automation Alliance Member Together with Pepperl+Fuchs, the Emerson Alliance Program provides a total automation solution Emerson and Pepperl+Fuchs have worked together

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Distributed Intrinsically Safe Fieldbus Applications

Distributed Intrinsically Safe Fieldbus Applications Application Note FB01-1 - Distributed Intrinsically Safe Fieldbus Applications Emerson Process Management DeltaV DCS System Pepperl+Fuchs June 2003 Application Note FB01-2 - c Pepperl+Fuchs Inc. All rights

More information

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE FACTORY AUTOMATION MANUAL WCS MODBUS RTU INTERFACE MODULE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and

More information

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90 FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90 . 1 System overview............................................. 5 2 Sensor versions..............................................

More information

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 With regard to the supply of products, the current issue of the following document is applicable: The General Terms

More information

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

FACTORY AUTOMATION QUICK START GUIDE IC-KP-* FACTORY AUTOMATION QUICK START GUIDE IC-KP-* IDENTControl units With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products

More information

QUICK START GUIDE IC-KP2-*

QUICK START GUIDE IC-KP2-* FACTORY AUTOMATION QUICK START GUIDE IC-KP2-* IDENTControl Compact control interfaces With regard to the supply of products, the current issue of the following document is applicable: The General Terms

More information

FACTORY AUTOMATION SAFETY LIGHT CURTAINS SLCS AND SLCT SERIES

FACTORY AUTOMATION SAFETY LIGHT CURTAINS SLCS AND SLCT SERIES FACTORY AUTOMATION SAFETY LIGHT CURTAINS SLCS AND SLCT SERIES 2 THE SERIES SLCS AND SLCT - SAFETY LIGHT CURTAINS OF THE SLIM MEST DIMENSION High resolution, ultra-slim profile safety light curtains are

More information

technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur

technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur For Foundation fieldbus networks in hazardous areas Complete enclosure systems for 6 or 12 intrinsically

More information

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES HOST INTERFACE MODULES With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0 FACTORY AUTOMATION MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0 SAFETY AT WORK With regard to the supply of products, the current issue of the following document is applicable: The General

More information

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description Block device couplers Data sheet 3177_en_A 1 Description PHOENX CONTACT 2015-01-20 2 Features The and block couplers provide an interface between the fieldbus trunk cable and field devices on Foundation

More information

FACTORY AUTOMATION TAILORED TO YOUR APPLICATION MODULAR SAFETY MONITORING UNIT

FACTORY AUTOMATION TAILORED TO YOUR APPLICATION MODULAR SAFETY MONITORING UNIT FACTORY AUTOMATION TAILORED TO YOUR APPLICATION MODULAR SAFETY MONITORING UNIT THE SUITABLE MONITORING UNIT FOR YOUR MACHINE PROTECTION The requirements on safety systems for today's machines and installations

More information

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div. Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function

More information

Enclosures for Remote I/O System I.S. 1

Enclosures for Remote I/O System I.S. 1 STAINLESS STEEL (V2A) STAINLESS STEEL (V4A) POLYESTER RESIN IP66 For Installation in II 2 G EEx e II Increased safety protection Certified according to 94/9EG (ATEX) For Installation in Zone 2 Declaration

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

BA414DF Fieldbus indicator Single variable

BA414DF Fieldbus indicator Single variable FIELDBUS DISPLAYS BA4xx Series BA6xx Series Hazardous area Safe area NEW BA414DF indicator Single variable Shown with optional stainless legend plate Power Supply & Segment Coupler Host Intrinsically safe

More information

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet FACTORY AUTOMATION INSTRUCTION MANUAL WCS-Interface Module, DeviceNet WCS-DG210 Part. No. 202340 / DOCT-1305 / 11. june 2007 1 Working principle............................ 6 2 Installation and commissioning.................

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001 PROCESS AUTOMATION MANUAL Z-System Zener Barriers ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15 FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15 Inductive angle positioning system With regard to the supply of products, the current issue of the following document is applicable: The General Terms

More information

FACTORY AUTOMATION. Manual IVI-KHD2-4HD1. Control Unit

FACTORY AUTOMATION. Manual IVI-KHD2-4HD1. Control Unit FACTORY AUTOMATION Manual Control Unit With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical

More information

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail Switch Amplifier KCD-SR-Ex.LB Features Assembly -channel isolated barrier V DC supply (Power Rail) Dry contact or NAMUR inputs Usable as signal splitter ( input and outputs) Relay contact output Fault

More information

PROCESS AUTOMATION MANUAL F2-SP-IC*

PROCESS AUTOMATION MANUAL F2-SP-IC* R PROCESS AUTOMATION MANUAL F2-SP-IC* Segment Protector With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and

More information

Roxar CorrLog High Accuracy Corrosion Monitoring

Roxar CorrLog High Accuracy Corrosion Monitoring FA-T200-C Product Data Sheet 01.12.2016 High Accuracy Corrosion Monitoring Fast and reliable corrosion monitoring is a key for efficient corrosion management and control. In-line corrosion monitoring provides

More information

MANUAL Temperature Multi-Input Device

MANUAL Temperature Multi-Input Device R PROCESS AUTOMATION MANUAL Temperature Multi-Input Device F2D0-TI-Ex8.PA.* RD0-TI-Ex8.PA.* With regard to the supply of products, the current issue of the following document is applicable: The General

More information

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs Overview This document provides information relating to the use of THE BARRIER HiC2, the SMART universal barrier from Pepperl+Fuchs, a

More information

FACTORY AUTOMATION. Manual IVI-KHD2-4HD3. Control Unit with 8 Inputs/Outputs

FACTORY AUTOMATION. Manual IVI-KHD2-4HD3. Control Unit with 8 Inputs/Outputs FACTORY AUTOMATION Manual Control Unit with 8 Inputs/Outputs With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

SYSTEMS AND COMPONENTS

SYSTEMS AND COMPONENTS PROCESS AUTOMATION SYSTEMS AND COMPONENTS FOR HAZARDOUS EX-AREAS AND INDUSTRIAL APPLICATIONS You are cordially invited to make the acquaintance of a firm renowned for its innovative strengths and its deep-rooted

More information

MANUAL Multi-Input/Output Device

MANUAL Multi-Input/Output Device PROCESS AUTOMATION MANUAL Multi-Input/Output Device F2D0-MIO-Ex12.PA.* R8D0-MIO-Ex12.PA.* R With regard to the supply of products, the current issue of the following document is applicable: The General

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1 FACTORY AUTOMATION MANUAL VAA-2E-G4-SE Original Instructions Version 1.1 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30 Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30 - Ex zone 1 and 2, as well as 21 and 22 - Metal enclosure - Available in stainless steel enclosure - Reed contacts, coded - Actuation

More information

PROCESS AUTOMATION SIMPLIFY PROCESSES FIELDCONNEX INFRASTRUCTURE FOR PROFIBUS PA

PROCESS AUTOMATION SIMPLIFY PROCESSES FIELDCONNEX INFRASTRUCTURE FOR PROFIBUS PA PROCESS AUTOMATION SIMPLIFY PROCESSES FIELDCONNEX INFRASTRUCTURE FOR PROFIBUS PA SIMPLIFY PROCESSES The best solutions are usually very simple The fieldbus is a perfect example of simplicity at its best.

More information

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2 FACTORY AUTOMATION INSTRUCTION MANUAL AS-Interface Safety at Work VAA-2E-G4-SN Version 1.2 With regard to the supply of products, the current issue of the following document is applicable: The General

More information

FACTORY AUTOMATION MANUAL MAH* FIRMWARE UPGRADE INSTRUCTIONS

FACTORY AUTOMATION MANUAL MAH* FIRMWARE UPGRADE INSTRUCTIONS FACTORY AUTOMATION MANUAL MAH* FIRMWARE UPGRADE INSTRUCTIONS With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current

More information

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure Indication and Adjustment Product Information VEGADIS 61 Level Switching Pressure 2 VEGADIS 61 Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2 Principle of operation... 4 1.3 Adjustment...

More information

FACTORY AUTOMATION TAMING THE POWER F99 SERIES INCLINATION AND ACCELERATION SENSORS

FACTORY AUTOMATION TAMING THE POWER F99 SERIES INCLINATION AND ACCELERATION SENSORS FACTORY AUTOMATION TAMING THE POWER F99 SERIES INCLINATION AND ACCELERATION SENSORS F99 SERIES INCLINATION AND ACCELERATION SENSORS Do you want to monitor the inclination angle of your machine components

More information

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital Design Benefits The Future is Digital Teo Puay Yong Pepperl+Fuchs On Behalf of FF Marketing Society 1 The Future is Digital Design Benefits from Applying Foundation Fieldbus Bus structure and Wiring Loop

More information

QUICK START GUIDE 2-D Laser Scanner

QUICK START GUIDE 2-D Laser Scanner FACTORY AUTOMATION QUICK START GUIDE 2-D Laser Scanner DE OMD0M-R2000-B2 OMD0M-R2000-B2 OMD2M-R2000-B2 OMD0M-R2000-B2 OMD0M-R2000-B2 OMD2M-R2000-B2 DE With regard to the supply of products, the current

More information

DC Power Considerations for Intrinsically Safe Applications

DC Power Considerations for Intrinsically Safe Applications Chapter 3 Intrinsically Safe Fieldbus Applications This chapter provides information about fieldbus applications that provide Intrinsically Safe (IS) power to fieldbus devices located in hazardous areas.

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

FACTORY AUTOMATION EASY DETECTION OF SMALL PARTS SLOT AND SLOT GRID SENSORS

FACTORY AUTOMATION EASY DETECTION OF SMALL PARTS SLOT AND SLOT GRID SENSORS FACTORY AUTOMATION EASY DETECTION OF SMALL PARTS SLOT AND SLOT GRID SENSORS 2 SLOT AND SLOT GRID SENSORS Slot and slot grid sensors work according to the familiar principle of thru-beam sensors and are

More information

PROCESS AUTOMATION. MANUAL Compact Fieldbus Power Hub, Common Interface

PROCESS AUTOMATION. MANUAL Compact Fieldbus Power Hub, Common Interface PROCESS AUTOMATION MANUAL Compact Fieldbus Power Hub, Common Interface With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for

More information

About the FLEX Ex I/O Systems

About the FLEX Ex I/O Systems Section 2.1 About the FLEX Ex I/O Systems 1797 FLEX Ex I/O Overview FLEX Ex I/O offer: Adapter Terminal base I/O module Bus connectors Keyswitch FlexBus connectors 24V DC field power Terminal strips FLEX

More information

FOUNDATION. Product Overview. Foundation Fieldbus

FOUNDATION. Product Overview. Foundation Fieldbus FOUNDATION Product Overview Foundation Fieldbus PROFIBUS PA Process Fieldbus wired infrastructure Control cabinet The Fieldbus (FB ) line of modular fieldbus components offers connectivity from the process

More information

PROCESS AUTOMATION MANUAL FIELDBUS POWER HUB INVENSYS

PROCESS AUTOMATION MANUAL FIELDBUS POWER HUB INVENSYS PROCESS AUTOMATION MANUAL FIELDBUS POWER HUB INVENSYS Advanced high performance power supplies and conditioner With regard to the supply of products, the current issue of the following document is applicable:

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

FACTORY AUTOMATION MANUAL VISION CONFIGURATOR

FACTORY AUTOMATION MANUAL VISION CONFIGURATOR FACTORY AUTOMATION MANUAL VISION CONFIGURATOR Software With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

07. har-link INTERFACE CONNECTORS

07. har-link INTERFACE CONNECTORS . INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

SOLUTIONS FOR THE PHARMACEUTICAL INDUSTRY Solutions for the Pharmaceutical Industry

SOLUTIONS FOR THE PHARMACEUTICAL INDUSTRY Solutions for the Pharmaceutical Industry Planning and construction of super skids Solutions for the Pharmaceutical Industry Comprehensive know-how on fieldbus technology for USA TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Phone: (763)

More information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Safety instructions. IECEx TUN Ex ia IIC T6 Gb Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions

More information

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3 FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3 Bluetooth modem for data matrix/rfid handhelds With regard to the supply of products, the current issue of the following document is applicable: The General Terms

More information

Roxar SandLog High Accuracy Sand/Erosion Monitoring

Roxar SandLog High Accuracy Sand/Erosion Monitoring FA-T201-C Product Data Sheet 01.12.2016 High Accuracy Sand/Erosion Monitoring The effective management of sand is important for the integrity of oil and gas assets and for optimizing production. Together

More information

80265 series, 3/2 Indirect solenoid actuated poppet valve

80265 series, 3/2 Indirect solenoid actuated poppet valve > > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,

More information

FACTORY AUTOMATION. M18 Threaded light beam switches

FACTORY AUTOMATION. M18 Threaded light beam switches FACTORY AUTOMATION M18 Threaded light beam switches M12-VarioQuick connectors Rapid connection method reduces installation and service costs Clear control panel with special bright LED indicators Green

More information

process automation protecting your process

process automation protecting your process process automation protecting your process PROCESS AUTOMATION For over a half century, Pepperl+Fuchs has provided new concepts for the world of process automation. Our company sets standards in quality

More information

SERVING THE WORLD S INFRASTRUCTURE PRODUCTS AND SOLUTIONS FOR THE POWER AND UTILITY INDUSTRIES

SERVING THE WORLD S INFRASTRUCTURE PRODUCTS AND SOLUTIONS FOR THE POWER AND UTILITY INDUSTRIES PROCESS AUTOMATION SERVING THE WORLD S INFRASTRUCTURE PRODUCTS AND SOLUTIONS FOR THE POWER AND UTILITY INDUSTRIES FIELDBUS INFRASTRUCTURE SIGNAL CONDITIONING SAFETY BARRIERS REMOTE I/O SYSTEMS WIRELESS

More information

FACTORY AUTOMATION. QUICK START GUIDE VBP-HH1-V3.0-V1 AS-Interface Handheld

FACTORY AUTOMATION. QUICK START GUIDE VBP-HH1-V3.0-V1 AS-Interface Handheld FACTORY AUTOMATION QUICK START GUIDE VBP-HH1-V.0-V1 AS-Interface Handheld With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

07. har-link Interface Connectors

07. har-link Interface Connectors . Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

QUICK START GUIDE ODT-HH-MAH300 Handheld

QUICK START GUIDE ODT-HH-MAH300 Handheld FACTORY AUTOMATION QUICK START GUIDE ODT-HH-MAH300 Handheld Laser Class 2M EN 60825-1 The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association

More information

Pepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power

Pepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power Pepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power The Fieldbus Power Hub connects to one or two +24 VDC input power supplies and provides redundant fieldbus power to up to four fieldbus segments.

More information

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001 PROCESS AUTOMATION MANUAL Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The general terms of delivery

More information

MANUAL SEGMENT CHECKER

MANUAL SEGMENT CHECKER PROCESS AUTOMATION MANUAL SEGMENT CHECKER A UNIVERSAL AND EASY-TO- USE SEGMENT DESIGN TOOL FOR FIELDBUS NETWORKS With regard to the supply of products, the current issue of the following document is applicable:

More information

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P Type designation Ident-No. 6811073 Nominal system voltage System power supply Admissible range V+ Nominal current V+ Max. current V+ Electrical isolation Via DeviceNet 18 30VDC 430 ma 4 A The 8XSG I/O

More information

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D FACTORY AUTOMATION Manual Speed Monitor KFU8-DW-.D With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services

More information

HERION SERIES Indirect solenoid actuated spool valves

HERION SERIES Indirect solenoid actuated spool valves HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: A-14038 File No: 899.60 Job Id: 262.1-017581-1 This is to certify: That the Peripheral Equipment with type designation(s) Fieldbus devices Issued to Pepperl+Fuchs

More information