RT2E Compact temperature switch Explosion proof

Size: px
Start display at page:

Download "RT2E Compact temperature switch Explosion proof"

Transcription

1 ompact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2, 21, 22 pplications Power generation safety equipment Water treatment Valve and compressor control Technical Data Temperature range to Temperature Process : mbient : (T5) (T6) torage : Repeatability E conformity ± 1% F.. / constant temperature cycle Low Voltage Directive 2014/35/EU TEX Directive 2014/34/EU Protection rating IP 66 (EN 60529) Process Bulb cale Weight Housing Mounting Ground tainless steel (316L) tainless steel (316L) bulb Ø 9.5 mm Internal graduated scale 2.00 kg + transmission Grey painted aluminum housing Explosion proof Wall mounting 2 x M6 x 16 screws Via internal or external terminal block Electrical Via internal terminal block with cable gland 3/4 NPT certified TEX/IEEx for Ø7 to 12 mm cable Electrical function ee ordering code details page 5 djustment Internal adjustment possible for set point and dead band TEX/IEEx ertificate LIE 02 TEX 6219X IEEx LIE X lassification II 2 G D Ex d II T6 or T5 Gb Ex tb III T80 or T95 Db Options ustomer specific set point adjustment ode ETP Mounting on 2" pipe ode 0407 tainless steel tag plate and wire ode 9941 Page 1 / 5

2 ompact temperature switch Explosion proof Principle vapour filled flexible sensing element actuates a microswitch by means of a piston. The set point is adjusted by means of a compressible spring installed in opposition. P T et point and reset point must be between 10% and 90% of the selected scale. tandard factory adjustment etpoint at 50% of the scale on falling temperature ustomer speciffic factory adjustment (option ETP) The following specifications have to be given with the order: etpoint value djustment on falling or raising temperature Dead band value (as needed) when using an adjustable dead band switch djustable ranges Micro-switch dead band 1) cale T max ode djustable dead band Fixed dead band R L M - P U (2 x PDT) 10% 90% 10% 90% 10% 90% 10% 90% ) The value of the dead band is depending on the value of the set point. This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value correspond to the dead band spring totally released and the higher correspond to the dead band spring fully tensed. For other set points the dead band value can be calculated by linear interpolation between the values at 10% and 90%. Page 2 / 5

3 ompact temperature switch Explosion proof Micro switches characteristics witch code R L M P U Type djustable dead band Fixed dead band tandard Gold contact Ultra sensitive Double 6 Vdc N/ m Vdc N/ m Vdc N/ m Vdc N/ m Vdc N/ m N/ Vdc N/ m N/ Vdc N/ m N/ Vac m N/ Vac N/ N/ Dielectric rigidity between contacts and ground 2000 V 2000 V 2000 V 1000 V 2000 V Electrical s OM 1 PDT Yellow / green OM OM 2 PDT Yellow / green Hazardous areas : zone 1, 2, 21, Ta +70 Dust IP6x Gases T surface lass Ta = T6 Ta = T5 Important : Maximum power dissipated inside enclosure does not exceed 5 W ll necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's temperature to such that it reaches the self-ignition temperature of the gas in which it is used. Page 3 / 5

4 ompact temperature switch Explosion proof Dimensions (mm) Direct mount temperature switches Temperature switches with capillary = Bulb length (temperature sensitive part) = dditional stem length (min. 25 mm) 2 fixing holes for M6 screw P = Immersion length (P = + ) K = apillary length (only TD1, TD2, TD3) E = Extension between process and housing only TRDE1 and TRDE2 TEX/IEEx certified able gland (not mounted) For version TD1 there is no additional stem length ( = 0). The sliding is mounted on the capillary. K ±2% Ø 44 E K ±2% Ø 8 Ø 2,6 Ø 8 Ø 8 P ±3 P ±3 Ø 9,5 Ø 9,5 TRDE TD1 TD2 TD3 tainless steel sliding male (TD2/3, TRDE1/2) tainless steel sliding male (TD1) lamping nut Thread and sizes F G 1/2 1/2 NPT lamping nut Thread and sizes F G 1/2 1/2 NPT ring F B H L H L /flat 17/flat B 23/flat 23/flat Tightness fittings B H L H L /flat 27/flat B 27/flat 27/flat fter tightening of the clamping nut, the stem is fixed in the process. Tight up to 40 bar. F Waterproof after tightening mounted on the capillary. Bulb length () according to the capillary length (K) and the temperature range (code) apillary ode TRDE1 n/a / mm n/a 100 n/a n/a TRDE2 n/a / mm TD1, TD2, TD3 K = m / mm TD1, TD2, TD3 K = m / mm TD1, TD2, TD3 K = m / mm Versions with = 150 mm or = 200 mm are not feasible with P = 150 mm Page 4 / 5

5 ompact temperature switch Explosion proof Ordering details RT2E RT2.. / Model ompact temperature switch RT2 pprovals TEX/IEEx Explosion proof E Pressure switches 1 PDT standard change over switch L 1 PDT gold contact change over switch M 1 PDT hermetically ultra sensitive change over switch P 1 PDT change over switch with adjustable dead band R 2 PDT double change over switch U. Temperature range ( ) (not for TRDE1) (not for TRDE1) (not for TRDE1) 48. Type of transmission TD1 tainless steel capillary without protection 1 TD2 tainless steel capillary with stainless steel protection 2 TD3 tainless steel capillary with stainless steel protection and PV coating 3 TRDE1 Rigid transmission with E=65 mm for temperature measurement below 120 TRDE2 Rigid transmission with E=120 mm for all temperature measurement D apillary length (K) Direct mounting (for TRDE1 and TRDE2) 0 1 meter 1 2 meters 2 3 meters 3 4 meters 4 5 meters 5 6 meters 6 7 meters 7 8 meters 8 9 meters 9 10 meters Immersion length (P) Immersion length (P) = Bulb length () + additional stem length () P = + 25 mm (minimum additional stem length = 25 mm, for see table on page 4) 0 P = 150 mm (not for TD1) 3 P = 250 mm (not for TD1) 4 P = 400 mm (not for TD1) 5 P = 600 mm (not for TD1) 6 P = 1000 mm (not for TD1) D Bulb diameter Ø 9.5 mm Process Without 0 G1/2 male (standard) 3 1/2 NPT male 6 Options to be added behind the / (see example below) / Ordering example with options ompact temperature switch TEX/IEEx Explosion proof 1 PDT standard change over switch Temperature range Transmission TD2 apillary 1 meter Immersion length 150 mm Bulb Ø 9.5 mm Process G 1/2 Option : tainless steel tag plate and wire RT2 E L / 9941 Page 5 / 5

RT2Y Compact temperature switch intrinsic safety

RT2Y Compact temperature switch intrinsic safety ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications

More information

Gas-actuated thermometer Stainless steel version Model 73

Gas-actuated thermometer Stainless steel version Model 73 Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical

More information

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves 66, 87, /, 5/ & 5/ > > Port size: G/ & G/ > > Compact design > > Easily interchangeable solenoid > > tandard manual override > > ll valves available with Ex protected coils (TEX or other international

More information

Solenoid Valves PN16 for gas flow interception

Solenoid Valves PN16 for gas flow interception s 7 684 INTELLIGAS Solenoid Valves PN16 for gas flow interception E... 2 way solenoid valves, threaded or flanged connections, brass or bronze body. 12V DC or 230V AC coil with manual reset. Normally Open

More information

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6012/5 > For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination

More information

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual Your Global Flow Control Partner Series 50 Valve Status Monitor Table of Contents 1. Definition of Terms... 2 2. Safety... 2 3. Storage... 3 4. Commissioning... 3 4.1. Mounting your VSM... 3 4.2. Wiring

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Linear Luminaire with LED Series 6412/5

Linear Luminaire with LED Series 6412/5 > For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

Threaded resistance thermometer Miniature design Model TR10-D

Threaded resistance thermometer Miniature design Model TR10-D Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion

More information

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 ) The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed

More information

Level limit switch Series RF 3000 Selection list. Overview 2

Level limit switch Series RF 3000 Selection list. Overview 2 Table of content Overview 2 Page Applications 4 ------------------------------------------------------------------------------------------------------------- RF 3100 6 Standard version -------------------------------------------------------------------------------------------------------------

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product

More information

Standard enclosure for Remote I/O Series 8150

Standard enclosure for Remote I/O Series 8150 > Stainless steel enclosure for installation in Zone 1 > Standard versions - available in max. 3 weeks > Prepared for the installation of IS1+ Remote I/O > For up to 112 analog or 224 digital signals >

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview. Overview onfiguration 2-wire, 78 GHz FMW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft). enefits rugged stainless steel design for industrial applications

More information

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06 PRODUCT MANUAL Rotork YTC Limited VERSION 1.06 Contents 1 Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 1.3 Explosion Proof Warning... 4 2 Product Description...

More information

ExCos-P Pressure sensor 20 Pa Pa

ExCos-P Pressure sensor 20 Pa Pa ExCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue output EC type-approved in acc. with ATEX

More information

Hazardous Location plug and receptacle

Hazardous Location plug and receptacle DX Hazardous Location plug and receptacle Main Advantages u u Rugged Construction, cost effective design Rated f Zone 1 and Zone 21 applications Features & Ratings p. 209 Certifications & Testing p. 210

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

G 1/2 30,5 A Brass NBR 0,8 3,

G 1/2 30,5 A Brass NBR 0,8 3, 4/2 way poppet valves electromagnetic actuated, directly controlled /4 & /2 Working from 0 bar up Suitable for vacuum range down.33 0-2 mbar l/s Protection class : IP 65, Ex em, Ex d TEX approved (see

More information

Resistance thermometer With spring-loaded tip Model TR55

Resistance thermometer With spring-loaded tip Model TR55 Temperature Resistance thermometer With spring-loaded tip Model TR55 WIKA data sheet TE 60.55 for further approvals see page 2 Applications Bearing temperature measurement on: Pumps Gears Motors Special

More information

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual

More information

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485 www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Grounding Monitoring Device Series 8485

Grounding Monitoring Device Series 8485 www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with

More information

Safety switches with manual mechanical delay and separate actuator

Safety switches with manual mechanical delay and separate actuator D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.

More information

PRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS.

PRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS. MESSKO MPreC PRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS. MESSKO MPreC -Series LARGE MESSKO PRESSURE RELIEF DEVICE (LMPRD) Operating pressure Project/Reference: Gasket material MPreC Typ 4 psi; 0.28

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection

Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection Page 1/6 Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection Brief description Surface-mounting thermostats control and monitor thermal processes. Thermostats

More information

Safety instructions Overvoltage protection B81-35

Safety instructions Overvoltage protection B81-35 Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

MPreC - Pressure Relief Device Order specification sheet

MPreC - Pressure Relief Device Order specification sheet - Pressure Relief Device Order specification sheet -Series LARGE MESSKO PRESSURE RELIEF DEVICE Complete the Order-N o by choosing the specific add-on s: e.g.: LMPRD 685-08-22-N01-00 Order-N o : Parameter

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC

More information

Threaded thermocouple Miniature design Model TC10-D

Threaded thermocouple Miniature design Model TC10-D Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology

More information

Polyester enclosures

Polyester enclosures Polyester enclosures Features Polyester enclosures hemical-resistant Temperature-resistant Flame-retardant Use in Ex areas with a surface resistance < 10 9 Ω, black enclosure orrosion-proof Seawater-proof

More information

Limit Switch Box YT-870/875 SERIES

Limit Switch Box YT-870/875 SERIES Limit Switch Box YT-870/875 SERIES PRODUCT MANUAL VERSION 1.01 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 3 2. Product

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS Flexibility Data configuration with HART configurator Measuring of gauge and absolute pressure Reliability Continuous self-diagnostic

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to

More information

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012 ERNG-X DERNG2108X012 Description The ERNG-X is a steady state no bleed engineered system for accurate and reliable control of Natural Gas. The ERNG-X includes a pressure regulator, preconditioning filters,

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Safety switches with separate actuator

Safety switches with separate actuator 4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC

More information

Pressure switch, Differential pressure switch RT

Pressure switch, Differential pressure switch RT Data sheet switch, Differential switch RT An RT switch contains a operated single-pole changeover contact, the position of which depends on the in the inlet connection and the set scale value. The RT series

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

DTB-1. Digital Thermometer Battery Powered

DTB-1. Digital Thermometer Battery Powered Digital Thermometer Battery Powered Battery powered 100mm stainless steel case (IP65) Direct mount, panel mount, or surface mount Clear 6 digit alphanumeric LCD display Configured C or F High accuracy

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Pressure switches and thermostats, types KP and KPI

Pressure switches and thermostats, types KP and KPI Features Wide regulating range Small dimensions Space-saving - easy to install in panels Ultra-short bounce time. Limits wear to an absolute minimum and increases reliability. Electrical connection at

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

FEATURES DESCRIPTION

FEATURES DESCRIPTION JUNCTION BOXES FEATURES Allows easy and safe device connections to the fieldbus (Fo u n d at i o n fieldbus TM, PROFIBUS) HART and even for standard instrumentation wiring 4-20 ma; Ideal for coupling sensors,

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC

More information

Flow. (l/min) (ms) N/en

Flow. (l/min) (ms) N/en 66, 87 Inline / & / spool valves electromagnetic actuated, indirectly controlled G / & G / For single and double operated actuators Manual override with and without detent imple design of soft seal spool

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity

More information

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS HART Non-HART Smart Temperature Transmitters with HART Protocol Universal Input: RTD, TC, Ohm & mv Program with PC or HART Communicator Low-Cost

More information

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2 > For use in hazardous areas with gas group IIB+H 2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Product manual plug, sockets and coupler 16 A.- Z0251

Product manual plug, sockets and coupler 16 A.- Z0251 Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these

More information

8125 Series Terminal Boxes

8125 Series Terminal Boxes 8125 Series Terminal oxes TERMINTION Ready-Term 8125 Terminal oxes Features: Pre-onfigured with terminals mounted Materials: Stainless Steel or arbon Steel Six enclosure sizes with different depths For

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified

More information

Approx. 4 s, measured in oil, with a probe Ø of 10 mm made of stainless steel. Influential effect of the ambient temperature

Approx. 4 s, measured in oil, with a probe Ø of 10 mm made of stainless steel. Influential effect of the ambient temperature sales@jumo.co.uk info.us@jumo.net Page/6 Dial Thermometer Type 608225 Special features Class Display ranges from -40 C to +600 C Temperature indicator as built-in or add-on device Stainless steel case

More information

Viamaster LED Series Luminaires For NEC and CEC Governed Hazardous Locations

Viamaster LED Series Luminaires For NEC and CEC Governed Hazardous Locations Class I, Division, Groups A, B, C, D Class I, Zone, Group IIC Class II, Division, Groups F, G Zone, Group IIIB Type R,, X Applications For use in locations where: Flammable gases, vapors and dusts are

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

DR7100 SERIES Supplementary instructions

DR7100 SERIES Supplementary instructions DR700 SERIES Supplementary instructions Guided Radar (TDR) Level Instrument for 2-wire control systems Supplementary Instructions for ATEX applications AMETEK Drexelbrook - EDO -0-2, DR700-LM ATEX, Issue

More information

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER Datasheet ECHOMX XPS-10 ULTRSONIC TRNSDUCER Supplied by.com Call us on + (0)118 916 920 Email info@27able.com Overview transducers use ultrasonic technology to measure level in a wide range of liquids

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Control Switches for Panel Mounting Series 8003

Control Switches for Panel Mounting Series 8003 > Switch function many switching arrangements ( or spring-return) possible via coding easy change of the coding possible on site max. 2 pole > For > With flexible lead or spring cage terminal www.stahl.de

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Operating pressure (bar) kv factor (m 3 /h) *3)

Operating pressure (bar) kv factor (m 3 /h) *3) / way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar

More information

Instruction Manual. T3110 T3110L T3110Ex

Instruction Manual. T3110 T3110L T3110Ex www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

red-y industrial series Thermal Mass Flow Meters and Controllers for Gases

red-y industrial series Thermal Mass Flow Meters and Controllers for Gases Thermal Mass Flow Meters and ontrollers for Gases High accuracy for heavy duties: Mass Flow Meters & ontrollers with IP67 & x Protection Reliable technology and industry standard interfaces for rough environments:

More information

21023, 21025, 2/2 Direct solenoid actuated poppet valves

21023, 21025, 2/2 Direct solenoid actuated poppet valves 03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap

More information

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Control Stations & Switches: Switches, Circuit Breakers and Break Glass Call Points SWE Series: 16 and 20 A Switches Increased Safety SWE Series: 16 and 2 A Switches Increased Safety 16 A Version - Type 1 16 A Version - Type 2 2 A Version Compliance Data: ATEX - IEC: Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T6 Ex td A21 T8 C IP66 -

More information

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview Overview The combination of sensor SONO 3300 sensor and FUS060 transmitter is ideal for applications within the general industry. Measurements are independent of liquid temperature, density, pressure and

More information

Bimetal spiral. Graduation: Scale angle Over-temperatures (occasionally allowed) Pointer. Dial. Accuracy (according to EN 13190) Class 1

Bimetal spiral. Graduation: Scale angle Over-temperatures (occasionally allowed) Pointer. Dial. Accuracy (according to EN 13190) Class 1 Technical Datasheet GB Series With rigid or every angle stem Watertight casing stainless steel execution NS 100-125 - 150 Indication ranges included between -50 to + C Execution B made with traditional

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety Applications Designed for use in Zone 1 or 2 areas where flammable gases or vapors are present either continuously or intermittently. Ideal for use in wet or corrosive atmospheres. Petroleum, chemical,

More information

SMARTLINE RM76 Supplementary instructions

SMARTLINE RM76 Supplementary instructions SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the

More information

Pressure switch, Differential pressure switch RT

Pressure switch, Differential pressure switch RT Data sheet switch, Differential switch RT An RT switch contains a operated single-pole changeover contact, the position of which depends on the in the inlet connection and the set scale value. The RT series

More information