1 2016 Product Catalogue v 1.0

2

3 CINERGIA develops and supplies AC and Regenerative Power Converters for Industrial, R&D and Academic applications Who we are CINERGIA is the result of more than ten years of experience in the conception, design, manufacture and commissioning of customized power electronics solutions. Our core competencies are the development of power electronics converters, DSP-based digital control, industrial communications and process automation. Our know-how is the result of continuous R+D in the fields of electrical conversion, electromobility, renewable resources and smart grids. Our products CINERGIA supplies high-technology products based on an industrial hardware platform designed to work 24/7. By using different DSP firmware, developed by CINERGIA, our standard product portfolio includes, AC and &AC power sink/sources. Regenerative Thanks to its bidirectional topology all our products can regenerate the test energy back to the grid, reducing the energy consumption and optimizing the electrical installation. Our value We provide cutting edge technology at costcompetitive prices thanks to the combination of a robust industrial platform with CINERGIA s proprietary control system. We can adapt our solutions to your specific needs and provide the engineering support to achieve the desired result thanks to the knowledge and experience of our engineering team.

4 SOLUTIONS ELECTROMOBILITY Electromomobility needs expertise in energy storage, batteries, battery charging, traction converters, power supplies, communications and its control. CINERGIA supplies power electronics equipments and platforms for test in production lines, prototype validation, burn-in and R&D. Grid Emulator Grid Battery Charger AC/ Battery Emulator Bms + Batteries Vsc Inverter Traction Converter Motor Test Bench Generator Electronic Load AC/AC SMART GRIDS IEC defines the smart grid as an electricity network that intelligently integrate the actions of all its users- generators, consumers and those that do both. It is related with electrical vehicles, energy storage systems (ESS), renewable generation (DER), consumers, grid.tied/islanded systems, communication and energy management. CINERGIA can provide complete test solutions for Smartgrid Labs and Original Equipment Manufacturers. Grid Emulator Grid Battery Emulator Microgrid Manager Batteries Battery Charger (B2C) Electrical Vehicle Wind Turbine Emulator AC/AC Battery Charger Electrical Vehicle Pv Emulator /AC Ac Load u. DER e. Electronic Load platform ACADEMIC AND R&D CINERGIA is your partner in Academic and R&D applications by adapting our standard products to the specific coming from academic and research requirements. Grid Emulator Grid programmable source AC/ Customer equipment Device Under test Electronic load (regenerative) /AC AC platform TEST PLATFORMS CINERGIA offers power electronics equipments, marked in green colour in the diagrams, as well as complete turn key solutions, for your testing needs: at the laboratory, production line, prototype and pre-series validation, burn-in, quality and R&D. Grid Emulator Grid AC programmable source AC/AC Customer equipment Device Under test Electronic load (regenerative) AC/AC

5 SELECTION GUIDE Voltage Source AC Grid Emulator GE-AC AC Electronic Load EL-AC High Frequency AC Electronic Load (EL-AC) AC& Voltage Source GE-AC& AC& Current Source EL-AC& Current Source Harmonics Grid disturbances 10 to 400Hz 360 to 800Hz PAGE Contact us for further information Constant Voltage Constant Current Constant Power Constant Resistance Battery Charge Battery Emulation PAGE 13 Power Supply PS Electronic Load EL Bidirectional Battery Charger B2C Battery Emulator BE AC& Voltage Source GE-AC& AC& Current Source EL-AC& 33 37

6 GEAC_2016_v1 GE-AC Grid Emulator CINERGIA s Grid Emulators are AC programmable voltage sources specially designed to create AC grids and emulate its disturbances. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid. FUNCTIONAL DESCRIPTION Generation of AC grid systems: -Three-phase system (3F+N) up to 480Vrms line-line -Single-phase system (F+N) up to 277Vrms line-neutral -Programmable frequency from 10 to 400Hz -Programmable phase angle -Programmable internal resistance Generation of grid disturbances: -Voltage harmonics up to 780Hz (except 8,10, 12 and 14th) -Flicker -Over and Undervoltage -Interruptions -Voltage dips symetric and unsymetric (types A, B, C, D). -Frequency fluctuations. -Automatic test files (*.csv) All disturbances can be configured in amplitude, duration and repetition time. Applications: Test of UPS, Photovoltaic and Eolic Inverters, EV Quick Battery Chargers, Vehicle to Grid (V2G), Energy Storage Systems (ESS) and other AC devices. KEY FEATURES 7.5 kva 200 kva 4 Quadrant Power Supply Regenerative up to 100% rated power AC Output: 25 to 277 Vrms, phase-neutral 43 to 480 Vrms, phase-phase up to 230Arms per phase Hz Independent configuration per phase: - Voltage magnitude - Phase angle - Harmonics (up to 780Hz) Disturbance generation: Interruptions and voltage dips, Flicker, Over and Undervoltage, Frequency Fluctuation AC& version available CINERGIA Pintor Roig i Soler, , Badalona, BARCELONA cinergia@cinergia.coop T

7 GEAC_2016_v1 GE-AC Grid Emulator CONCEPTUAL SCHEMATIC Grid Emulator GRID AC AC EQUIPMENT UNDER TEST (EUT) BACK-TO-BACK TOPOLOGY Optional The equipment is formed by two IGBT-based power stages: a grid-side Active Rectifier producing sinusoidal currents with low harmonic distortion and close to unity power factor; and an output side AC Inverter generating three independent AC voltages with programmable amplitude, phase angle and harmonic content by using a digital resonant control algorithm. Thanks to the bidirectionality of this topology the test energy can be injected back to the grid. TECHNICAL DIAGRAM OF GE AC IN (GRID side) AC OUT (EUT side) 3 P + N 3 P + N EMC filter -U -U EMC filter Current Drivers x 6 Voltage Drivers x 6 sensor x 2 Current Voltage DSP control CAN DSP control Voltage HMI MODBUS/TCP ETHERNET AC Input is connected to the grid (neutral wire or DYn isolation transformer is required) AC Output is connected to the Equipment Under Test (EUT) and can be used as: - Three-phase AC system - Three independent Single-phase AC systems (same frequency) - One parallelized Single-phase AC system (3 times rated current per phase) 2

8 GEAC_2016_v1 Balanced voltage dips GE-AC Grid Emulator FUNCTIONALITIES Undervoltage Voltage interruptions Balanced voltage dips Unbalanced voltage dips Voltage Harmonics Independent phase harmonics 400Hz Aeronautics Grid Frequency fluctuation Flicker Transient time 2-5ms 3

9 GEAC_2016_v1 GE-AC Grid Emulator USER INTERFACE Local 3.2 Touchscreen panel Remote Control port: LAN Ethernet with Modbus/TCP protocol. SOFTWARE FEATURES Windows 7/10 user interface for remote operation and data acquisition. Digital IO port: -4 digital inputs -3 relay outputs -1 Emergency stop Optional analog port: -1 analog input 0-10V -3 analog outputs 0-10V Optional communications: RS485, RS232, CAN, LabView Configuration of harmonics Configuration of disturbances Cooling The power supply is air-cooled internally. Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. Options Galvanic Isolation Isolation monitor High Voltage (up to 295Vrms, p-n) Analog Input/Output Port RS485, RS232, CAN Labview drivers 4

10 GEAC_2016_v1 GE-AC Grid Emulator RANGE AND SPECIFICATIONS MAGNITUDE VALUE Power 7.5kVA-200kVA Input side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power 0.99 Configurable by user 0-1 (capacitive/inductive) Efficiency (at rated power) >92% Overload 125% for 10 min / % for 60 s Output side (EUT side) AC Voltage Phase-neutral Vrms (10-100Hz) Vrms ( Hz) 25-Vrms ( Hz) Rated AC Current1 Depends on model (see table) Arms Frequency Fundamental voltage Hz (0.1Hz resolution) Harmonics Per phase 1st - 15th at 50Hz (except 8,10,12 & 14) 1st - 13th at 60Hz (except 8,10&12) 1st above 100Hz Harmonic content Maximum % 1st: 100% 2nd-11th: 50%, 13th-15th:10% Modes of operation Constant Voltage Range2 Resolution3 Ripple % <0.1% <1% Disturbance Generation Voltage dip and interruptions Over and Undervoltage Frequency variation Flicker Harmonic sequence General Measurements User interface Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures 3.2 Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP 10-90% (Absolute maximum, without condensation) 5-35 ºC (Absolute maximum) Forced air Over Current, Over Voltage, Shortcircuit, Overtemperature Humidity Temperature Cooling Protections Standards CE Marking Safety EN , EN EMC EMC: EN Rated AC Current depends on model (see table) and defines the maximum permanent current allowed. Minimum current is 0A. 2 Range is related to rated values of each model as defined in table MODELS 3 Resolution and ripple are related to the FS of each model. Contact us for further information. All specifications are subject to change without notice. 5

11 GEAC_2016_v1 GE-AC Grid Emulator GE MODELS REFERENCE GE7.5-AC GE10-AC GE15-AC GE20-AC GE30-AC GE40-AC GE50-AC GE60-AC GE80-AC GE100-AC GE120-AC GE160-AC GE200-AC RATED kva kw All specifications are subject to change without notice. GALVANIC ISOLATION (optional) RATED CURRENT AC rms / phase AC rms/ global Independent mode Parallel mode 10A 30A 15A 45A 20A 60A 25A 75A 40A 120A 50A A 65A 195A 80A 240A 105A 315A 130A 390A 155A 465A 185A 555A 230A 690A WEIGHT kg DIMENSIONS DxWxH (mm) 770x450x x590x x900x2000 REFERENCE RECOMMENDED CIRCUIT BREAKER WEIGHT kg DIMENSIONS DxWxH (mm) IT7.5 IT10 IT15 IT20 IT30 IT40 IT50 IT60 IT80 IT100 IT120 IT160 IT200 Type C - 25A Type C - 25A Type C - 32A Type C - 40A Type D - 80A Type D - 100A Type D - 125A Type D - 160A Type D - 200A Type D - 250A Type D - 315A Type D - 400A Type D - 500A (*) The transformer is delivered in a stand-alone cabinet IP23 All specifications are subject to change without notice Inside the cabinet 595x415x708 (*) 789x490x865 (*) 964x684x1252 (*) 1192x744x1430 (*) 6

12 ELAC_2016_v1 EL-AC Electronic Load AC Electronic Loads are power electronics devices that behave as an AC electrical load. While most electronic loads are dissipative, CINERGIA offers a comprehensive range of, AC and AC& full 4Q and full regenerative electronic loads. FUNCTIONAL DESCRIPTION KEY FEATURES Operation modes: -Constant Current (CC) -Constant Power (CP) -Constant Impedance (CI) -Automatic test from csv file 7.5 kva 200 kva 4 Quadrant Power Supply Applications: R&D, production and reliability tests for applications requiring linear and non-linear AC loads. Test of AC voltage sources, UPS, AC generators and electrical devices (as fuses, circuit breakers and connectors). In Smartgrid applications it can be used to emulate domestic appliances, a house, a building as well as grid-coupled generators: PV and eolic plants, Energy Storage Systems, Electrical Vehicles, V2G-Vehicle to Grid and other AC distributed generators. 80% typical energy and power saving: GRID 11.1 kw η=90% 19.1kW kW Equipment Under Test (EUT) 92 kw 100 kw AC Electronic Load AC 8 kw η = 92% 92 kw Regenerative up to 100% rated power Full 4Q: pure capacitive and inductive current AC Output: up to 230Arms per phase 25 to 277 Vrms, phase-neutral Hz Independent configuration per channel: - Fundamental current up to 400Hz - Harmonics up to 780Hz - Phase angle (-1 < cos < 1) - Non-linear currents - Crest factor <3 - Active / Reactive Power AC& version available CINERGIA Pintor Roig i Soler, , Badalona, BARCELONA cinergia@cinergia.coop T

13 ELAC_2016_v1 EL-AC Electronic Load CONCEPTUAL SCHEMATIC Electronic Load GRID AC AC EQUIPMENT UNDER TEST (EUT) BACK-TO-BACK TOPOLOGY Optional The equipment is formed by two IGBT-based power stages: a grid-side Active Rectifier producing sinusoidal currents with low harmonic distortion and close to unity power factor; and an output side AC Inverter generating three independent AC currents with programmable amplitude, phase angle and harmonic content by using a digital resonant control algorithm. Thanks to the bidirectionality of this topology the test energy can be injected back to the grid. TECHNICAL DIAGRAM OF EL-AC AC IN (GRID side) AC OUT (EUT side) 3 P + N 3 P + N EMC filter - - EMC filter Current Drivers x 6 Voltage Drivers x 6 sensor x 2 Current Voltage DSP control CAN DSP control Voltage HMI MODBUS/TCP ETHERNET AC Input is connected to the grid (neutral wire or DYn isolation transformer is required) AC Output is connected to the Equipment Under Test (EUT) and can be used as: - Three-phase AC Wye load (balanced or unbalanced) - Three independent Single-phase AC systems (different voltage/frequency is possible) - One parallelized Single-phase AC system (3 times rated current per phase) 8

14 ELAC_2016_v1 EL-AC Electronic Load FUNCTIONALITIES Resistive load Pure capacitive load Pure inductive load Harmonics Single-phase rectifier Three-phase rectifier Phase delay Phase delay + harmonics Independent phase control In previous oscilloscope captures: AC source under test (yellow), EL currents phase A, B and C (green, magenta, blue) 9

15 ELAC_2016_v1 EL-AC Electronic Load USER INTERFACE Local 3.2 Touchscreen panel Remote Control port: LAN Ethernet with Modbus/TCP protocol. SOFTWARE FEATURES Windows 7/10 user interface for remote operation and data acquisition. Digital IO port: -4 digital inputs -3 relay outputs -1 Emergency stop Optional analog port: -1 analog input 0-10V -3 analog outputs 0-10V Optional communications: RS485, RS232, CAN, LabView Configuration of harmonics Configuration of disturbances Cooling The power supply is air-cooled internally. Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. Options Galvanic Isolation Isolation monitor Low Current Ripple High Voltage (up to 295Vrms, p-n) Analog Input/Output Port RS485, RS232, CAN Labview drivers 10

16 ELAC_2016_v1 EL-AC Electronic Load RANGE AND SPECIFICATIONS MAGNITUDE VALUE Power 7.5kVA-200kVA Input side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power 0.99 Configurable by user 0-1 (capacitive/inductive) Efficiency (at rated power) >92% Overload 125% for 10 min / % for 60 s Output side (EUT side) AC Voltage Rated maximum, ch-neutral Vrms (10-100Hz) Vrms ( Hz) 25-Vrms ( Hz) Rated AC Current1 Independent mode Arms per channel Parallel mode Arms global Frequency Fundamental current Hz Power factor Configurable by user 0-1 (capacitive/inductive) Harmonic Configurable by user 1st - 15th at 50Hz (except 8,10,12 & 14) 1st - 13th at 60Hz (except 8,10&12) 1st at 400Hz Harmonic content Maximum % 1st-9th: 100% 11th: 50%, 13th-15th:10% Crest factor <3 Modes of operation Range2 Resolution3 Ripple3 Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Constant Impedance (R,L,C) min.-100% <±0.1% <1% General Measurements User interface Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage (Vrms) and Current (Irms) Temperatures 3.2 Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP 10-90% (Absolute maximum, without condensation) 5-35 ºC (Absolute maximum) Forced air Over Current, Over Voltage, Shortcircuit, Overtemperature Humidity Temperature Cooling Protections Standards CE Marking Safety EN , EN EMC EMC: EN Rated AC Current depends on model (see table) and defines the maximum permanent current allowed. Minimum current is 0A. 2 Range is related to rated values of each model as defined in table MODELS 3 Resolution and ripple are related to the FS of each model. Contact us for further information. All specifications are subject to change without notice. 11

17 ELAC_2016_v1 EL-AC Electronic Load EL-AC MODELS REFERENCE EL7.5-AC EL10-AC EL15-AC EL20-AC EL30-AC EL40-AC EL50-AC EL60-AC EL80-AC EL100-AC EL120-AC EL160-AC EL200-AC RATED kva kw All specifications are subject to change without notice. RATED CURRENT AC rms / phase AC rms/ global Independent mode Parallel mode 10A 30A 15A 45A 20A 60A 25A 75A 40A 120A 50A A 65A 195A 80A 240A 105A 315A 130A 390A 155A 465A 185A 555A 230A 690A WEIGHT kg DIMENSIONS DxWxH (mm) 770x450x x590x x900x2000 GALVANIC ISOLATION (optional) REFERENCE RECOMMENDED CIRCUIT BREAKER WEIGHT kg DIMENSIONS DxWxH (mm) IT7.5 IT10 IT15 IT20 IT30 IT40 IT50 IT60 IT80 IT100 IT120 IT160 IT200 Type C - 25A Type C - 25A Type C - 32A Type C - 40A Type D - 80A Type D - 100A Type D - 125A Type D - 160A Type D - 200A Type D - 250A Type D - 315A Type D - 400A Type D - 500A (*) The transformer is delivered in a stand-alone cabinet IP23 All specifications are subject to change without notice Inside the cabinet 595x415x708 (*) 789x490x865 (*) 964x684x1252 (*) 1192x744x1430 (*) 12

18 PS_2016_v1 PS Programmable Power Supply CINERGIA s converters are power electronics devices designed to generate a constant voltage, current, power, resistance or IU battery charge profile. Our products (PS, EL-, B2C) differ in the possible operation modes. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid. FUNCTIONAL DESCRIPTION Operation modes: -Constant Voltage (CV) -Constant Current (CC) -Constant Power (CP) -Automatic test from csv file Three channels in each unit: The three channels can be controlled independently allowing different voltage, current or power setpoints. In standard units the Operation mode will be the same for the three channels. Optionally, each channel could be operated in different mode (if interested, please ask for option Independent Channels Operation). 2Q or 4Q applications: -In 2Q applications, the EUT will be connected between one channel and the common negative. -In 4Q applications, the EUT will be connected between two channels KEY FEATURES kw 2/4 Quadrant Power Supply Regenerative up to 100% rated power 1 channel Output: 20 to 750V, 0 to ±555A 3 channels Output: 20 to 750V, 0 to ±185A/ch Bipolar Output -350 to +350V, 0 to ±185A +270V/0/-270V Output for Avionics applications CV, CC, CP modes Option for Independent Channels Operation CINERGIA Pintor Roig i Soler, , Badalona, BARCELONA cinergia@cinergia.coop T

19 PS_2016_v1 PS Programmable Power Supply CONCEPTUAL SCHEMATIC Power Supply GRID AC EQUIPMENT UNDER TEST (EUT) BACK-TO-BACK TOPOLOGY Recommended The equipment is formed by two IGBT-based power stages: a grid-side Active Rectifier producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output converters generating three independent channels. Thanks to the bidirectionality of this topology the test energy can be injected back to the grid. TECHNICAL DIAGRAM AC IN (GRID side) OUT (EUT side) 3P+ N 3CH-COM EMC filter -U -U EMC filter CH1 CH2 CH3 Com_neg Current Drivers x 6 Voltage Drivers x 6 sensor x 2 Current Voltage DSP control CAN DSP control Voltage HMI MODBUS/TCP ETHERNET AC Input is connected to the grid (isolation transformer with neutral is recommended) Output is connected to the Equipment Under Test (EUT) and can be used as: - Independent channels mode: three 2Q channels with a common negative - Parallel channels mode: one 2Q channel (3 times rated current per phase) - One 4Q bipolar channel (connecting the load between two channels) - One +270/0/-270V channels for avionics applications 14

20 PS_2016_v1 0.0 PS Programmable Power Supply USER INTERFACE Local 3.2 Touchscreen panel Remote Control port: LAN Ethernet with Modbus/TCP protocol. SOFTWARE FEATURES Windows 7/10 user interface for remote operation and data acquisition. Digital IO port: -4 digital inputs -3 relay outputs -1 Emergency stop Optional analog port: -1 analog input 0-10V -3 analog outputs 0-10V Optional communications: RS485, RS232, CAN, LabView OPERATION AREA: UNIPOLAR OPERATION AREA: BIPOLAR Output voltage (V) Minimum voltage at rated power Independent channels mode Parallel channels mode Output voltage (V) -Bipolar Bipolar Minimum output voltage Output current (A) Output current (A) In UNIPOLAR the equipment under test is connected between a channel and the common negative. Two possible configurations: Independent channels: CH1, CH2 and CH3 are available and can be parametrized with different voltage, current or power setpoint. In BIPOLAR the equipment under test is connected between channels CH1, CH2 and CH3. The common negative is not connected and CH2 is used as 0V reference for CH1 and CH3. This connection will be used to create +270V/0/-270V avionics bus system. Parallelized channels: the three channels are shortcircuited internally to provide three times the current. Maximum voltage in bipolar connection is ±350V. Ask for further information if ±750V are needed. Cooling The power supply is air-cooled internally. Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. Options Galvanic Isolation (recommended) Isolation monitor Independent Channels Operation Analog Input/Output Port RS485, RS232, CAN Labview drivers 15

21 PS_2016_v1 PS Programmable Power Supply RANGE AND SPECIFICATIONS MAGNITUDE VALUE Power (grid side) 7.5kVA-200kVA Input side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power 0.99 Configurable by user 0-1 (capacitive/inductive) Efficiency (at rated power) >92% Overload 125% for 10 min / % for 60 s Output side (EUT side) Voltage Channel-Com_neg 20 to 750V ( 60kVA) Channel-Com_neg 40 to 750V (>60kVA) Channel-Channel -350 to 350V Minimum voltage at rated power1 320V Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Bipolar output 0 to ±185A per channel Overcurrent 110% during 1 min Operation Modes Range2 Resolution3 Ripple3 Constant Voltage 0-100% <±0.1% <1% Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Response time Rated resistance load 1-5ms (10-90%) General Measurements User interface Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures 3.2 Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP 10-90% (Absolute maximum, without condensation) 5-35 ºC (Absolute maximum) Forced air Over Current, Over Voltage, Shortcircuit, Overtemperature Humidity Temperature Cooling Protections Standards CE Marking Safety EN , EN EMC EMC: EN Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail 2 Range is related to rated values of each model as defined in table MODELS 3 Resolution and ripple are related to the FS of each model. Contact us for further information. All specifications are subject to change without notice. 16

22 PS_2016_v1 PS Programmable Power Supply MODELS REFERENCE PS7.5 PS10 PS15 PS20 PS30 PS40 PS50 PS60 PS80 PS100 PS120 PS160 PS200 RATED kva kw All specifications are subject to change without notice. RATED CURRENT Independent Parallel Bipolar 0-750v 0-750v -350 to 350V ±10A ±15A ±20A ±25A ±30A ±38A ±47A ±57A ±105A ±130A ±130A ±155A ±185A ±30A ±45A ±60A ±75A ±90A ±115A ±140A ±180A ±315A ±390A ±390A ±465A ±555A ±10A ±15A ±20A ±25A ±30A ±38A ±47A ±57A ±105A ±130A ±130A ±155A ±185A WEIGHT kg DIMENSIONS DxWxH (mm) 770x450x x590x x900x2000 GALVANIC ISOLATION (recommended) REFERENCE RECOMMENDED CIRCUIT BREAKER WEIGHT kg DIMENSIONS DxWxH (mm) IT7.5 IT10 IT15 IT20 IT30 IT40 IT50 IT60 IT80 IT100 IT120 IT160 IT200 Type C - 25A Type C - 25A Type C - 32A Type C - 40A Type D - 80A Type D - 100A Type D - 125A Type D - 160A Type D - 200A Type D - 250A Type D - 315A Type D - 400A Type D - 500A (*) The transformer is delivered in a stand-alone cabinet IP23 All specifications are subject to change without notice Inside the cabinet 595x415x708 (*) 789x490x865 (*) 964x684x1252 (*) 1192x744x1430 (*) 17

23 EL_2016_v1 EL- Electronic Load CINERGIA s converters are power electronics devices designed to generate a constant voltage, current, power, resistance or IU battery charge profile. Our products (PS, EL-, B2C) differ in the possible operation modes. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid. FUNCTIONAL DESCRIPTION Operation modes: -Constant Current (CC) -Constant Power (CP) -Constant Resistance (CR) Three channels: -The three channels can be controlled independently, allowing different setpoints on each channel -The three channels can be controlled in parallel, sharing the same setpoint and providing 3 times the current -In Unipolar 2Q applications, the sources will be connected between one channel and the common negative. -In Bipolar 4Q applications, the source will be connected between two channels 80% typical energy saving by regenerating to the grid: GRID 11.1 kw η=90% 19.1kW kW Equipment Under Test (EUT) 92 kw 100 kw -Constant Voltage (CV) -Automatic test from csv file Electronic Load AC 8 kw η = 92% 92 kw KEY FEATURES kw 2/4 Quadrant Power Supply Regenerative up to 100% rated power 1 channel Output: 20 to 750V, 0 to ±555A 3 channels Output: 20 to 750V, 0 to ±185A/ch Bipolar Output -350 to +350V, 0 to ±185A +270V/0/-270V Output for Avionics applications CV, CC, CP, CV modes Option for Independent Channels Operation AC& version available CINERGIA Pintor Roig i Soler, , Badalona, BARCELONA cinergia@cinergia.coop T

24 EL_2016_v1 EL- Electronic Load CONCEPTUAL SCHEMATIC Electronic Load GRID AC EQUIPMENT UNDER TEST (EUT) BACK-TO-BACK TOPOLOGY Recommended The equipment is formed by two IGBT-based power stages: a grid-side Active Rectifier producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output converters generating three independent channels. Thanks to the bidirectionality of this topology the test energy can be injected back to the grid. TECHNICAL DIAGRAM AC IN (GRID side) OUT (EUT side) 3P+ N 3CH-COM EMC filter -U -U EMC filter CH1 CH2 CH3 Com_neg Current Drivers x 6 Voltage Drivers x 6 sensor x 2 Current Voltage DSP control CAN DSP control Voltage HMI MODBUS/TCP ETHERNET AC Input is connected to the grid (isolation transformer with neutral is recommended) Output is connected to the Equipment Under Test (EUT) and can be used as: - Independent channels mode: three 2Q channels with a common negative - Parallel channels mode: one 2Q channel (3 times rated current per phase) - One 4Q bipolar channel (connecting the load between two channels) - One +270/0/-270V channels for avionics applications 19

25 EL_2016_v1 0.0 EL- Electronic Load USER INTERFACE Local 3.2 Touchscreen panel Remote Control port: LAN Ethernet with Modbus/TCP protocol. SOFTWARE FEATURES Windows 7/10 user interface for remote operation and data acquisition. Digital IO port: -4 digital inputs -3 relay outputs -1 Emergency stop Optional analog port: -1 analog input 0-10V -3 analog outputs 0-10V Optional communications: RS485, RS232, CAN, LabView OPERATION AREA: UNIPOLAR OPERATION AREA: BIPOLAR Output voltage (V) Minimum voltage at rated power Independent channels mode Parallel channels mode Output voltage (V) -Bipolar Bipolar Minimum output voltage Output current (A) Output current (A) In UNIPOLAR the equipment under test is connected between a channel and the common negative. Two possible configurations: Independent channels: CH1, CH2 and CH3 are available and can be parametrized with different voltage, current or power setpoint. In BIPOLAR the equipment under test is connected between channels CH1, CH2 and CH3. The common negative is not connected and CH2 is used as 0V reference for CH1 and CH3. This connection will be used to create +270V/0/-270V avionics bus system. Parallelized channels: the three channels are shortcircuited internally to provide three times the current. Maximum voltage in bipolar connection is ±350V. Ask for further information if ±750V are needed. Cooling The power supply is air-cooled internally. Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. Options Galvanic Isolation (recommended) Isolation monitor Independent Channels Operation Analog Input/Output Port RS485, RS232, CAN Labview drivers 20

26 EL_2016_v1 EL- Electronic Load RANGE AND SPECIFICATIONS MAGNITUDE VALUE Power (grid side) 7.5kVA-200kVA Input side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power 0.99 Configurable by user 0-1 (capacitive/inductive) Efficiency (at rated power) >92% Overload 125% for 10 min / % for 60 s Output side (EUT side) Voltage Channel-Com_neg 20 to 750V ( 60kVA) Channel-Com_neg 40 to 750V (>60kVA) Channel-Channel -350 to 350V Minimum voltage at rated power1 320V Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Bipolar output 0 to ±185A per channel Overcurrent 110% during 1 min Operation Modes Range2 Resolution3 Ripple3 Constant Voltage 0-100% <±0.1% <1% Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Constant Resistance Min.-100% <±0.1% <1% Response time Rated resistance load 1-5ms (10-90%) General Measurements User interface Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures 3.2 Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP 10-90% (Absolute maximum, without condensation) 5-35 ºC (Absolute maximum) Forced air Over Current, Over Voltage, Shortcircuit, Overtemperature Humidity Temperature Cooling Protections Standards CE Marking Safety EN , EN EMC EMC: EN Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail 2 Range is related to rated values of each model as defined in table MODELS 3 Resolution and ripple are related to the FS of each model. Contact us for further information. All specifications are subject to change without notice. 21

27 EL_2016_v1 EL- Electronic Load MODELS REFERENCE EL7.5- EL10- EL15- EL20- EL30- EL40- EL50- EL60- EL80- EL100- EL120- EL160- EL200- RATED kva kw All specifications are subject to change without notice. RATED CURRENT Independent Parallel Bipolar 0-750v 0-750v -350 to 350V ±10A ±30A ±10A ±15A ±45A ±15A ±20A ±60A ±20A ±25A ±75A ±25A ±30A ±90A ±30A ±38A ±115A ±38A ±47A ±140A ±47A ±57A ±180A ±57A ±105A ±315A ±105A ±130A ±390A ±130A ±130A ±390A ±130A ±155A ±465A ±155A ±185A ±555A ±185A WEIGHT kg DIMENSIONS DxWxH (mm) 770x450x x590x x900x2000 GALVANIC ISOLATION (recommended) REFERENCE RECOMMENDED CIRCUIT BREAKER WEIGHT kg DIMENSIONS DxWxH (mm) IT7.5 IT10 IT15 IT20 IT30 IT40 IT50 IT60 IT80 IT100 IT120 IT160 IT200 Type C - 25A Type C - 25A Type C - 32A Type C - 40A Type D - 80A Type D - 100A Type D - 125A Type D - 160A Type D - 200A Type D - 250A Type D - 315A Type D - 400A Type D - 500A (*) The transformer is delivered in a stand-alone cabinet IP23 All specifications are subject to change without notice Inside the cabinet 595x415x708 (*) 789x490x865 (*) 964x684x1252 (*) 1192x744x1430 (*) 22

28 B2C Bidirectional Battery Charger CINERGIA s converters are power electronics devices designed to generate a constant voltage, current, power, resistance or IU battery charge profile. Our products (PS, EL-, B2C) differ in the possible operation modes. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid. FUNCTIONAL DESCRIPTION Operation modes: -Battery Charge (BC) -Constant Voltage (CV) -Constant Current (CC) -Constant Power (CP) -Constant Resistance (CR) -Automatic test from csv file Three channels in each unit: The three channels can be controlled independently allowing different voltage, current or power setpoints. In standard units the Operation mode will be the same for the three channels. Optionally, each channel can be operated in different mode (option Independent Channels Operation). 2Q or 4Q applications: For testing bipolar current applications and bipolar voltage applications. Battery charge is controlled with an IUoU algorithm. Battery discharge can be done at constant current, power or resistance. Battery cycling is possible by programming a sequence in a csv file. KEY FEATURES kw 2/4 Quadrant Power Supply Regenerative up to 100% rated power 1 channel Output: 20 to 750V, 0 to ±555A 3 channels Output: 20 to 750V, 0 to ±185A/ch Bipolar Output -350 to +350V, 0 to ±185A +270V/0/-270V Output for Avionics applications BC, CV, CC, CP, CR modes IUoU and Equalization battery charge modes Constant current or power battery discharge B2C_2016_v2 23 CINERGIA Pintor Roig i Soler, , Badalona, BARCELONA cinergia@cinergia.coop T

29 B2C Bidirectional Battery Charger CONCEPTUAL SCHEMATIC B2C GRID AC EQUIPMENT UNDER TEST (EUT) BACK-TO-BACK TOPOLOGY Recommended The converter is formed by a grid-side Active Rectifier and an output converter sharing a -link. The Active Rectifier allows sinusoidal current consumption with low harmonic distortion and unity power factor. The converter generates three independent voltages controlling the voltage, current or power. TECHNICAL DIAGRAM AC IN (GRID side) OUT (EUT side) 3P+ N 3CH-COM EMC filter -U -U EMC filter CH1 CH2 CH3 Com_neg Current Drivers x 6 Voltage Drivers x 6 sensor x 2 Current Voltage DSP control CAN DSP control Voltage HMI MODBUS/TCP ETHERNET AC Input is connected to the grid (isolation transformer with neutral is recommended) B2C_2016_v2 Output is connected to the Equipment Under Test (EUT) and can be used as: - Independent channels mode: three 2Q channels with a common negative - Parallel channels mode: one 2Q channel (3 times rated current per phase) - One 4Q bipolar channel (connecting the load between two channels) - One +270/0/-270V channels for avionics applications 24

30 B2C Bidirectional Battery Charger USER INTERFACE SOFTWARE FEATURES Local 3.2 Touchscreen panel Remote Control port: LAN Ethernet with Modbus/TCP protocol. Windows 7/10 user interface for remote operation and data acquisition. Digital IO port: -4 digital inputs -3 relay outputs -1 Emergency stop Optional analog port: -1 analog input 0-10V -3 analog outputs 0-10V Optional communications: RS485, RS232, CAN, LabView OPERATION AREA: UNIPOLAR OPERATION AREA: BIPOLAR Output voltage (V) Independent channels mode Parallel channels mode Output voltage (V) -Bipolar Output current (A) Output current (A) In UNIPOLAR the equipment under test is connected between a channel and the common negative. Two possible configurations: Independent channels: CH1, CH2 and CH3 are available and can be parametrized with different voltage, current or power setpoint. In BIPOLAR the equipment under test is connected between channels CH1, CH2 and CH3. The common negative is not connected and CH2 is used as 0V reference for CH1 and CH3. This connection will be used to create +270V/0/-270V avionics bus system. Parallelized channels: the three channels are shortcircuited internally to provide three times the current. Maximum voltage in bipolar connection is ±350V. Ask for further information if ±750V are needed. B2C_2016_v2 Cooling The power supply is air-cooled internally. Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. 25 Options Galvanic Isolation (recommended) Isolation monitor Independent Channels Operation Analog Input/Output Port RS485, RS232, CAN Labview drivers

31 B2C Bidirectional Battery Charger RANGE AND SPECIFICATIONS MAGNITUDE VALUE Power (grid side) 7.5kVA-200kVA Input side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power 0.99 Configurable by user 0-1 (capacitive/inductive) Efficiency (at rated power) >92% Overload 125% for 10 min / % for 60 s Output side (EUT side) Voltage Channel-Com_neg 20 to 750V ( 60kVA) Channel-Com_neg 40 to 750V (>60kVA) Channel-Channel -350 to 350V Minimum voltage at rated power1 320V Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Bipolar output 0 to ±185A per channel Overcurrent 110% during 1 min Operation Modes Range2 Resolution3 Ripple3 Constant Voltage 0-100% <±0.1% <1% Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Constant Resistance Min.-100% <±0.1% <1% Battery Charge 0-±100% <±0.1% <1% Response time Rated resistance load 1-5ms (10-90%) General Measurements User interface Humidity Temperature Cooling Protections Standards CE Marking Safety EMC Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures 3.2 Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP 10-90% (Absolute maximum, without condensation) 5-35 ºC (Absolute maximum) Forced air Over Current, Over Voltage, Shortcircuit, Overtemperature EN , EN EMC: EN B2C_2016_v2 1 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail 2 Range is related to rated values of each model as defined in table MODELS 3 Resolution and ripple are related to the FS of each model. Contact us for further information. All specifications are subject to change without notice. 26

32 B2C Bidirectional Battery Charger MODELS REFERENCE B2C7.5 B2C10 B2C15 B2C20 B2C30 B2C40 B2C50 B2C60 B2C80 B2C100 B2C120 B2C160 B2C200 RATED kva kw All specifications are subject to change without notice. GALVANIC ISOLATION (recommended) RATED CURRENT Independent Parallel Bipolar 0-750v 0-750v -350 to 350V ±10A ±15A ±20A ±25A ±30A ±38A ±47A ±57A ±105A ±130A ±130A ±155A ±185A ±30A ±45A ±60A ±75A ±90A ±115A ±140A ±180A ±315A ±390A ±390A ±465A ±555A ±10A ±15A ±20A ±25A ±30A ±38A ±47A ±57A ±105A ±130A ±130A ±155A ±185A WEIGHT kg DIMENSIONS DxWxH (mm) 770x450x x590x x900x2000 REFERENCE RECOMMENDED CIRCUIT BREAKER WEIGHT kg DIMENSIONS DxWxH (mm) IT7.5 IT10 IT15 IT20 IT30 IT40 IT50 IT60 IT80 IT100 IT120 IT160 IT200 Type C - 25A Type C - 25A Type C - 32A Type C - 40A Type D - 80A Type D - 100A Type D - 125A Type D - 160A Type D - 200A Type D - 250A Type D - 315A Type D - 400A Type D - 500A (*) The transformer is delivered in a stand-alone cabinet IP23 All specifications are subject to change without notice Inside the cabinet 595x415x708 (*) 789x490x865 (*) 964x684x1252 (*) 1192x744x1430 (*) B2C_2016_v2 27

33 BE_2016_v1 BE Battery Emulator A Battery Emulator is a power electronics device that behaves as a real battery pack. CINERGIA s BE is based on a regenerative power supply. When emulating a battery charge, the energy will be injected back to the electrical grid consuming a sinusoidal current with unity power factor and low harmonic distortion. Using a BE will save space in the laboratory, avoiding safety issues of real batteries and allow a high flexibility in the tests. FUNCTIONAL DESCRIPTION Operation modes: -Constant Voltage (CV) -Static -Dynamic Three channels: The three channels can be configured independently, allowing emulation of different batteries at the same time The three channels can be configured in parallel, emulating one single battery with 3 times the rated current capabilityv Static mode: the emulated battery voltage will depend on the open-circuit voltage and internal charge and discharge virtual resistance. KEY FEATURES kw 2 Quadrant Power Supply Regenerative up to 100% rated power 1 channel Output: 0 to 750V, 0 to ±555A 3 channels Output: 0 to 750V, 0 to ±185A/ch Constant Voltage, Static, and Dynamic modes Dynamic mode: the emulated battery voltage will depend on the State Of Charge, rate of discharge and internal charge and discharge virtual resistance. CINERGIA Pintor Roig i Soler, , Badalona, BARCELONA cinergia@cinergia.coop T

34 BE_2016_v1 BE Battery Emulator CONCEPTUAL SCHEMATIC Battery Emulator GRID AC EQUIPMENT UNDER TEST (EUT) BACK-TO-BACK TOPOLOGY Recommended The equipment is formed by two IGBT-based power stages: a grid-side Active Rectifier producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output converters generating three independent channels. Thanks to the bidirectionality of this topology the test energy can be injected back to the grid. TECHNICAL DIAGRAM AC IN (GRID side) OUT (EUT side) 3P+ N 3CH-COM EMC filter -U -U EMC filter CH1 CH2 CH3 Com_neg Current Drivers x 6 Voltage Drivers x 6 sensor x 2 Current Voltage DSP control CAN DSP control Voltage HMI MODBUS/TCP ETHERNET AC Input is connected to the grid (isolation transformer with neutral is recommended) Output is connected to the Equipment Under Test (EUT) and can be used as: - Independent channels mode: three 2Q channels with a common negative - Parallel channels mode: one 2Q channel (3 times rated current per phase) 29

35 BE_2016_v1 BE Battery Emulator USER INTERFACE CABINET Local 3.2 Touchscreen panel Remote Control port: LAN Ethernet with Modbus/TCP protocol. Digital IO port: -4 digital inputs -3 relay outputs -1 Emergency stop Cooling The power supply is air-cooled internally. Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. Optional analog port: -1 analog input 0-10V -3 analog outputs 0-10V Optional communications: RS485, RS232, CAN, LabView SOFTWARE INTERFACE Windows 7/10 user interface for remote operation and data acquisition. STATIC MODE The battery is emulated through a simplyfied model based on fixed Voc and charge/discharge resistors. Voc Rch Rdisch + Vout - DYNAMIC MODE A model based on battery manufacturer data allows realistic voltage and SOC behaviour. OPERATION AREA: 1/3 CHANNELS Output voltage (V) Minimum voltage at rated power ch mode 0.0-3ch mode 0 3ch mode 1ch mode Output current (A) 30

36 BE_2016_v1 BE Battery Emulator RANGE AND SPECIFICATIONS MAGNITUDE VALUE ower (grid side) 7.5kVA-200kVA Input side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power 0.99 Configurable by user 0-1 (capacitive/inductive) Efficiency (at rated power) >92% Overload 125% for 10 min / % for 60 s Output side (EUT side) Voltage Channel-Com_neg 20 to 750V ( 60kVA) Channel-Com_neg 40 to 750V (>60kVA) Minimum voltage at rated power1 320V Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Overcurrent 110% during 1 min Operation Modes Range2 Resolution3 Ripple3 Constant Voltage 5-100% <±0.1% <1% Static 5-±100% <±0.1% <1% Dynamic 5-±100% <±0.1% <1% Response time Rated resistance load 1-5ms (10-90%) General Measurements User interface Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures 3.2 Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP 10-90% (Absolute maximum, without condensation) 5-35 ºC (Absolute maximum) Forced air Over Current, Over Voltage, Shortcircuit, Overtemperature Humidity Temperature Cooling Protections Standards CE Marking Safety EN , EN EMC EMC: EN Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail 2 Range is related to rated values of each model as defined in table MODELS 3 Resolution and ripple are related to the FS of each model. Contact us for further information. All specifications are subject to change without notice. 31

37 BE_2016_v1 BE Battery Emulator MODELS REFERENCE BE7.5 BE10 BE15 BE20 BE30 BE40 BE50 BE60 BE80 BE100 BE120 BE160 BE200 RATED kva kw All specifications are subject to change without notice. GALVANIC ISOLATION (recommended) RATED CURRENT Independent mode Parallel mode 0-750v 0-750v ±10A ±15A ±20A ±25A ±30A ±38A ±47A ±57A ±105A ±130A ±130A ±155A ±185A ±30A ±45A ±60A ±75A ±90A ±115A ±140A ±180A ±315A ±390A ±390A ±465A ±555A WEIGHT kg DIMENSIONS DxWxH (mm) 770x450x x590x x900x2000 REFERENCE RECOMMENDED CIRCUIT BREAKER WEIGHT kg DIMENSIONS DxWxH (mm) IT7.5 IT10 IT15 IT20 IT30 IT40 IT50 IT60 IT80 IT100 IT120 IT160 IT200 Type C - 25A Type C - 25A Type C - 32A Type C - 40A Type D - 80A Type D - 100A Type D - 125A Type D - 160A Type D - 200A Type D - 250A Type D - 315A Type D - 400A Type D - 500A (*) The transformer is delivered in a stand-alone cabinet IP23 All specifications are subject to change without notice Inside the cabinet 595x415x708 (*) 789x490x865 (*) 964x684x1252 (*) 1192x744x1430 (*) OPTIONS Galvanic Isolation (recommended) Isolation monitor Isolated analog inputs RS485, RS232, CAN Labview drivers 32

38 GE-AC& AC& Voltage Source GE-AC& is the combination of two products in a single cabinet:a GE-AC and a PS. The equipment can be used alternatively in AC or in providing the highest flexibility at a very competitive price. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid. FUNCTIONAL DESCRIPTION Two main modes: - AC mode: the three output channels work as AC Voltage Sources as a GE-AC - mode: the three output channels work as Voltage Sources (CV) or Current Sources (CC, CP) as a PS Three output channels: - Independent control - Parallel control AC mode: -Generation of AC 3-phase or 1-phase voltages -Configurable frequency from 10 to 400Hz -Configurable phase angle and internal resistance -Generation of disturbances See GE-AC datasheet for further information mode: -Operation modes: CV, CC and CP -Automatic test from Excel file -Unipolar 2Q or Bipolar 4Q applications See PS datasheet for further information KEY FEATURES kVA / kW 4 Quadrant Power Supply Regenerative up to 100% rated power AC Output: 25 to 277 Vrms, phase-neutral 43 to 480 Vrms, phase-phase up to 230Arms per phase Hz Output: 1 channel Output: 20 to 750V, 0 to ±555A 3 channels Output: 20 to 750V, 0 to ±185A/ch Bipolar Output -350 to +350V, 0 to ±185A +270V/0/-270V Output for Avionics applications GE_AC_v_v1 33 CINERGIA Pintor Roig i Soler, , Badalona, BARCELONA cinergia@cinergia.coop T

39 GE-AC& AC& Voltage Source CONCEPTUAL SCHEMATIC Grid Emulator GRID AC AC or EQUIPMENT UNDER TEST (EUT) BACK-TO-BACK TOPOLOGY Recommended The equipment is formed by two IGBT-based power stages: a grid-side Active Rectifier producing sinusoidal currents with low harmonic distortion and close to unity power factor; and depending on the main mode, an output converter that can be configured either as an AC inverter or as a converter. TECHNICAL DIAGRAM AC IN (GRID side) AC OUT (EUT side) 3 P + N 3 P + N + COM EMC filter EMC filter Current Drivers x 6 Voltage Drivers x 6 sensor x 2 Current Voltage DSP control CAN DSP control Voltage HMI MODBUS/TCP ETHERNET GE_AC_2016_v1 AC Input is connected to the grid (isolation transformer with neutral is recommended ) AC Output is connected to the Equipment Under Test (EUT) and can be used as AC or output. The loads or EUT are connected between a phase and: - AC mode: the output neutral - mode: the common (COM) negative point for 2Q applications or to phase for 4Q applications The AC or mode is selected by manual switch. 34

40 GE-AC& AC& Voltage Source USER INTERFACE Local 3.2 Touchscreen panel Remote Control port: LAN Ethernet with Modbus/TCP protocol. SOFTWARE FEATURES Windows 7/10 user interface for remote operation and data acquisition. Digital IO port: -4 digital inputs -3 relay outputs -1 Emergency stop Optional analog port: -1 analog input 0-10V -3 analog outputs 0-10V Optional communications: RS485, RS232, CAN, LabView Cooling The power supply is air-cooled internally. Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. Options Galvanic Isolation Isolation monitor Battery Charge mode (BC) IAnalog Input/Output Port RS485, RS232, CAN Labview drivers Constant Voltage Harmonics Disturbances Constant Current Constant Power Constant Resistance AC mode mode RANGE AND SPECIFICATIONS Detailed data can be found in datasheets of GE-AC and PS GE_AC_2016_v1 35

41 GE-AC& AC& Voltage Source GE-AC& MODELS REFERENCE GE7.5-AC& GE10-AC& GE15-AC& GE20-AC& GE30-AC& GE40-AC& GE50-AC& GE60-AC& GE80-AC& GE100-AC& GE120-AC& GE160-AC& GE200-AC& RATED kva kw All specifications are subject to change without notice. RATED CURRENT Independent Mode Parallel mode Arms/ch Adc/ch Arms Adc 10A 15A 20A 25A 40A 50A 65A 80A 105A 130A 155A 185A 230A ±10A ±15A ±20A ±25A ±30A ±38A ±47A ±57A ±105A ±130A ±130A ±155A ±185A GALVANIC ISOLATION (recommended) 30A 45A 60A 75A 120A A 195A 240A 315A 390A 465A 555A 690A ±30A ±45A ±60A ±75A ±90A ±115A ±140A ±180A ±315A ±390A ±390A ±465A ±555A WEIGHT kg DIMENSIONS DxWxH (mm) 770x450x x590x x900x2000 REFERENCE RECOMMENDED CIRCUIT BREAKER WEIGHT kg DIMENSIONS DxWxH (mm) IT7.5 IT10 IT15 IT20 IT30 IT40 IT50 IT60 IT80 IT100 IT120 IT160 IT200 Type C - 25A Type C - 25A Type C - 32A Type C - 40A Type D - 80A Type D - 100A Type D - 125A Type D - 160A Type D - 200A Type D - 250A Type D - 315A Type D - 400A Type D - 500A (*) The transformer is delivered in a stand-alone cabinet IP23 All specifications are subject to change without notice Inside the cabinet 595x415x708 (*) 789x490x865 (*) 964x684x1252 (*) 1192x744x1430 (*) GE_AC_2016_v1 36

42 EL-AC& AC& Electronic Load EL-AC& is the combination of two products in a single cabinet: an EL-AC and an EL-. The equipment can be used alternatively in AC or in providing the highest flexibility at a very competitive price. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid. FUNCTIONAL DESCRIPTION KEY FEATURES Two main modes: - AC mode: the three output channels work as AC Current Sources (CC, CP, CI) as EL-AC - mode: the three output channels work as a Voltage Source (CV) or a Current Source (CC, CP, CR) as EL- Three output channels: - Independent control - Parallel control AC mode: -Consumption of AC 3-phase or 1-phase current -100% configurable power factor, inductive and capacitive -Configurable harmonics -Operation modes: CC, CP, CI -Automatic test from Excel file mode: -Operation modes: CV, CC, CP and CR -Automatic test from Excel file -Unipolar 2Q or Bipolar 4Q applications kVA / kW 4 Quadrant Power Supply Regenerative up to 100% rated power AC Output: 1-phase Output: up to 690Arms 3-phase Output: up to 230Arms per channel 1 channel Output: 20 to 750V, 0 to ±555A 3 channels Output: 20 to 750V, 0 to ±185A/ch Bipolar Output -350 to +350V, 0 to ±185A +270V/0/-270V Output for Avionics applications Allowed Voltage: 25 to 277Vrms,p-n in AC 20 to 750V in VEL_AC_2016_v1 37 CINERGIA Pintor Roig i Soler, , Badalona, BARCELONA cinergia@cinergia.coop T

43 EL-AC& AC& Electronic Load CONCEPTUAL SCHEMATIC Electronic Load GRID AC AC or EQUIPMENT UNDER TEST (EUT) BACK-TO-BACK TOPOLOGY Recommended The equipment is formed by two IGBT-based power stages: a grid-side Active Rectifier producing sinusoidal currents with low harmonic distortion and close to unity power factor; and depending on the main mode, an output converter that can be configured either as an AC inverter or as a converter. TECHNICAL DIAGRAM AC IN (GRID side) AC OUT (EUT side) 3 P + N 3 P + N + COM EMC filter EMC filter Current Drivers x 6 Voltage Drivers x 6 sensor x 2 Current Voltage DSP control CAN DSP control Voltage HMI MODBUS/TCP ETHERNET EL_AC_2016_v1 AC Input is connected to the grid (isolation transformer with neutral is recommended ) AC Output is connected to the Equipment Under Test (EUT) and can be used as AC or output. The loads or EUT are connected between a phase and: - AC mode: the output neutral - mode: the common (COM) negative point for 2Q applications or to phase for 4Q applications The AC or mode is selected by manual switch. 38

44 EL-AC& AC& Electronic Load USER INTERFACE Local 3.2 Touchscreen panel Remote Control port: LAN Ethernet with Modbus/TCP protocol. SOFTWARE FEATURES Windows 7/10 user interface for remote operation and data acquisition. Digital IO port: -4 digital inputs -3 relay outputs -1 Emergency stop Optional analog port: -1 analog input 0-10V -3 analog outputs 0-10V Optional communications: RS485, RS232, CAN, LabView Cooling The power supply is air-cooled internally. Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. Options Galvanic Isolation (recommended) Isolation monitor Analog Input/Output Port RS485, RS232, CAN Labview drivers Constant Current Harmonics Constant Voltage Constant Power Constant Impedance Constant Resistance AC mode mode RANGE AND SPECIFICATIONS Detailed data can be found in datasheets of EL-AC and EL- EL_AC_2016_v1 39

B2C Bidirectional Battery Charger

B2C Bidirectional Battery Charger CINERGIA s converters are power electronics devices designed to generate a constant voltage, current, power, resistance or IU battery charge profile. Our products (PS, EL-, B2C) differ in the possible

More information

BE Battery Emulator KEY FEATURES FUNCTIONAL DESCRIPTION kw. 2 Quadrant Power Supply. Regenerative up to 100% rated power

BE Battery Emulator KEY FEATURES FUNCTIONAL DESCRIPTION kw. 2 Quadrant Power Supply. Regenerative up to 100% rated power A is a power electronics device that behaves as a real battery pack. CINERGIA s is based on a regenerative power supply. When emulating a battery charge, the energy will be injected back to the electrical

More information

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY VFI TYPE PF= 0.9 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS Built In Inverter Transformer for DC-AC Galvanic Protection

More information

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva GE Critical Power Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS 3 5 6 8 10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91

More information

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY Three LEVEL UPS VFI TYPE PF=.0 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS True Three Level Rectifier and Inverter Technology

More information

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity - Next Generation UPS for protecting your Business Critical Systems AC Power Systems for Business-Critical Continuity Advanced UPS Technology Protects Modern IT Equipment Today s advanced digital computing,

More information

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,

More information

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems Power Supplies Modular THOR Modular Modular UPS system Online double-conversion Scalable Decentralized Parallel Modular 10, 20, 30, 40kVA modules 10-520kVA systems Power factor 1.0 at 10/20kVA/kW modules

More information

Features. Description. Applications

Features. Description. Applications Description Features The electronic loads of the ZSAC series are optimized for the practical use in laboratories, manufacturing and quality control. Power: Voltage: Current: 400W... 12600W 260V... 440V

More information

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance

More information

Technical Data SINVERT PVS2000

Technical Data SINVERT PVS2000 Technical Data SINVERT PVS2000 The solar inverter is used in PV systems to convert the direct current from the PV generators into a three-phase current. This three-phase current is then fed into the connected

More information

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application MUST900 Modular UPS 30-300 kva modular UPS - up to 900 Datacenter & servers Internet centers Local Area Networks (LAN) Telecommunication devices Emergency application Smart Energy Solutions HOT SWAP 0.9

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

REGENERATIVE LOAD ERI SERIES

REGENERATIVE LOAD ERI SERIES Electronic DC Loads REGENERATIVE LOAD ERI SERIES The electronic loads of the ERI series feed the absorbed energy back into the local supply network. This protects the environment and reduces electricity

More information

Dynamic AC Emulator Testing charging technology and power electronics efficiently

Dynamic AC Emulator Testing charging technology and power electronics efficiently Dynamic AC Emulator Testing charging technology and power electronics efficiently Highlights Emulation of global grids The Dynamic AC Emulator (ACE) permits flexible, functional testing of any electrical

More information

Programmable laboratory power supplies direct from the manufacturer

Programmable laboratory power supplies direct from the manufacturer Programmable laboratory power supplies direct from the manufacturer is the perfect partner for standard solutions, system integrations and customer specific requirements Industry 4.0 compatible DC Sources

More information

2U/5U. AC + DC Power Solutions. Transient Generation for Disturbance Tests. only. High Performance Programmable AC Power Source

2U/5U. AC + DC Power Solutions. Transient Generation for Disturbance Tests. only. High Performance Programmable AC Power Source AFV-P series High Performance Programmable AC Power Source only 2U/5U i Output Frequency up to 15-1000Hz Intuitive Touch Screen HMI AC Source with DC output AC & DC Transient Generation for Disturbance

More information

Tel: AC Power for Business-Critical Continuity TM

Tel: AC Power for Business-Critical Continuity TM Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise

More information

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL 200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant

More information

Modular UPS S KVA

Modular UPS S KVA Scalable 3 - phase, double conversion UPS system with hot-plug design up to 220 KVA (n + 1). The modular design with 20 KVA modules makes any system up or downgrade flexible and avoids high inv estment

More information

REGENERATIVE LOAD ERI SERIES

REGENERATIVE LOAD ERI SERIES Electronic DC Loads REGENERATIVE LOAD ERI SERIES ERI Series Brief Profile The electronic loads of the ERI series feed the absorbed energy back into the local supply network. This protects the environment

More information

MP7. Uninterruptible Power Supply

MP7. Uninterruptible Power Supply Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3) MasterNOVA MasterNOVA 30-100 (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro 250-800 3/3) MasterNOVA The MasterNOVA UPS is one of the best performing and reliable UPS from GTEC, providing power protection

More information

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Distributed by Keor T UPS THREE-PHASE UPS from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES T THREE-PHASE UPS T has been designed with advanced technologies and the

More information

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT30KX Highlights On-line double-conversion topology, VFI operation

More information

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY OF CONTINUOUS SERVICE YEARS WARRANTY B8000 FXS 10-40kVA BORRI B8000 FXS With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS system is regarded as the most critical

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management. RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels 20 Channel Branch Circuit Monitoring Device with RCM Interfaces / communication RS485 RTU Accuracy of measurement

More information

InteliPro. Protection Relay for Parallel Applications. Technical Specification

InteliPro. Protection Relay for Parallel Applications. Technical Specification InteliPro Protection Relay for Parallel Applications Product description InteliPro is a highly flexible interconnection/mains decoupling protective relay with extensive protective functions. It meets the

More information

LAB-SCUBI SINGLE CHANNEL BIDIRECTIONAL PSU

LAB-SCUBI SINGLE CHANNEL BIDIRECTIONAL PSU ELECTRONIC TEST & POWER SYSTEMS LAB-SCUBI SINGLE CHANNEL BIDIRECTIONAL PSU POSITIVE PROBLEM SOLVING The LAB-SCUBI is a series of high power single channel Bidirectional PSUs. Each system is able to operate

More information

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION ALL PSU Ltd Unit D6 Laser Quay, Culpeper Close Medway City Estate, Rochester, Kent, ME2 4HU Phone: 01634-725527 Fax: 01634-739111 E-mail: sales@allpsu.co.uk Web: www.allpsu.co.uk ROTATION+ 6kVA - 10kVA

More information

MUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA

MUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA MUST 900 3 Phase Modular UPS Hot swappable, scalable 30kVA to 900kVA Finally the benefits of Modular ups are for all MUST 900 The MUST 900 series is an uninteruptible power supply, three phase input/output,

More information

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) MODEL NUMBER: SU80KX Description Tripp Lite's SU80KX (80kVA) SmartOnline Modular 3-Phase

More information

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3) MasterNOVA MasterNOVA 30-100 (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro 250-800 3/3) MasterNOVA The MasterNOVA UPS is one of the best performing and reliable UPS from GTEC, providing power protection

More information

JUNXY Series DC Load Banks

JUNXY Series DC Load Banks JUNXY Series DC Load Banks It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, AC & DC generator, rectifier, transformers, inverter etc working in good

More information

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity Galaxy VM 160/200 kva Parallel capable up to 800 kva Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that

More information

LAB-HPP COMPACT HIGH POWER DC SOURCES

LAB-HPP COMPACT HIGH POWER DC SOURCES ELECTRONIC TEST & POWER SYSTEMS LAB-HPP COMPACT HIGH POWER DC SOURCES POSITIVE PROBLEM SOLVING The LAB-HPP family can be used as a stand alone power supply or as component in a wider automated test system.

More information

Est ComPower Mini. Compact UPS kva

Est ComPower Mini. Compact UPS kva Est.1968 ComPower Mini Compact UPS 7.5 40 kva Cabinet A: Up to 15kVA with 10 min. Cabinet B: Up to 40kVA with 10 min. Cabinet C: Up to 40kVA with 20 min. ComPower Mini The Beauty of Power Protection Simplicity

More information

SG Series UPS kva three phase 400 Vac

SG Series UPS kva three phase 400 Vac GE Critical Power SG Series UPS 10-600 kva three phase 400 Vac with ultra-high efficiency eboost TM technology imagination at work From protecting assets such as generators, transmission lines and motors,

More information

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System MODEL NUMBER: SVX120KL Highlights 120kVA / 120kW modular, scalable, 3-phase, Large-Frame tower

More information

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM Liebert NXr Series 30kVA to 160kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across

More information

the Centric 300 An advanced modular UPS up to 1800kVA/kW

the Centric 300 An advanced modular UPS up to 1800kVA/kW the Centric 300 An advanced modular UPS up to 1800kVA/kW 1 Gamatronic, Israel s Leading Power Electronics Company True to the exceptional reputation earned by Israeli technology companies, Gamatronic has

More information

AFQevo Active Multi-Function Filter. AFQevo. Active Multi-Function Filter. Technology for energy efficiency

AFQevo Active Multi-Function Filter. AFQevo. Active Multi-Function Filter. Technology for energy efficiency Active Multi-Function Filter Active Multi-Function Filter Technology for energy efficiency HARMONICS More than just a simple problem In recent years, substantial growth in the number of electronic devices

More information

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications Modular three-phase UPS system Conceptpower DPA 10 250 kva True modular UPS system for critical applications A UPS designed to meet the needs of today and tomorrow The Conceptpower DPA is a high-power,

More information

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU40K Description Tripp Lite's SU40K (40kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

PRODUCT PRESENTATION PROTECT 1. April 2012 DATA&IT, SBU C-UPS, PM/SR

PRODUCT PRESENTATION PROTECT 1. April 2012 DATA&IT, SBU C-UPS, PM/SR PRODUCT PRESENTATION PROTECT 1. April 2012 DATA&IT, SBU C-UPS, PM/SR CONTENTS A CLASSIFICATION 3 B PRODUCT HIGHLIGHTS 8 C SUMMARY 25 2 A- CLASSIFICATION CLASSIFICATION ACC. TO -AEG S UPS PRODUCT PORTFOLIO

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

DPS SERIES DC POWER SUPPLIES

DPS SERIES DC POWER SUPPLIES DPS SERIES: 15kW - 60kW Key features: 15kW to 60kW Models Higher Power Configurations Available 3U Compact Form Factor Voltage Ranges up to 1200 Vdc Current Ranges up to 3000 Adc High-Speed Precision Metering

More information

aentron Energy System 1 to 900 Vdc

aentron Energy System 1 to 900 Vdc aentron Energy System 1 to 900 Vdc The aentron lithium-ion energy system enables the realisation of a modular and scalable lithium-ion battery solution. The management of large lithium-ion batteries systems

More information

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules MODEL NUMBER: SVX90KM3P5B Highlights 90kVA/90kW Modular, Scalable,

More information

SLI 15 INVERTER SERIES, 1500 W

SLI 15 INVERTER SERIES, 1500 W SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with

More information

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups Galaxy VX Highly efficient, scalable, three-phase power protection with flexible operating modes and ECOnversion for large facilities, data centers, and business-critical applications. From 500 to 1500

More information

SMARTONLINE E3 UPS SYSTEMS

SMARTONLINE E3 UPS SYSTEMS SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,

More information

CPS kVA TRIFASE EN50171

CPS kVA TRIFASE EN50171 PRINCIPLES OF WORKING The loads can be divided into two types: 1) Users always powered (SA). the users are always fed both in the presence and absence of the mains. 2) Users powered emergency service only

More information

LP 33 Series UPS. Digital Energy. GE Digital Energy

LP 33 Series UPS. Digital Energy. GE Digital Energy GE Digital Energy Digital Energy LP 33 Series UPS 40/60/80/100/120 kva three phase 400 Vac Active IGBT Rectifier & Active IGBT Rectifier Clean Input Module Uninterruptible Power Supply (UPS) imagination

More information

EMISSION MEASUREMENT Power Frequency Testing

EMISSION MEASUREMENT Power Frequency Testing EMISSION MEASUREMENT Power Frequency Testing This document has been optimized for electronic media POWER FREQUENCY TESTING QUALITY AND RELIABILITY OF THE POWER NETWORK The power network is an essential

More information

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A 3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A 2 Electronic Energy Recycling Load ERI Series Syntax Interface Overview RS-232 USB LAN GPIB O CAN Analog Analog isolated O Standard O Option /not available

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

MODULAR GRID-TIE SOURCE/SINK

MODULAR GRID-TIE SOURCE/SINK TopCon TC.GSS MODULAR GRID-TIE SOURCE/SINK SYSTEMS BY REGATRON Preliminary data V06_2010.2.e REGATRON AG Kirchstrasse 11 CH-9400 Rorschach / Switzerland 0041 846 67 67 Fone 0041 846 67 77 Fax www.regatron.ch

More information

SMART GRID POWER SOLUTIONS OFFICE AND DATACENTER

SMART GRID POWER SOLUTIONS OFFICE AND DATACENTER SMART GRID POWER SOLUTIONS OFFICE AND DATACENTER AEG PS OFFERS A RANGE OF COMPACT UPS PRODUCTS FOR SMALL AND HOME OFFICE APPLICATIONS AEG PS compact UPS product portfolio (extract) Home, SoHo PROTECT HOME.

More information

GE Critical Power. Single Phase UPS Overview. 1 Gabriele Andrighetti

GE Critical Power. Single Phase UPS Overview. 1 Gabriele Andrighetti GE Critical Power Single Phase UPS Overview 1 PRODUCT PORTFOLIO Line-Interactive True On-Line Double Conversion New Product Portfolio VCL Series CE 0.5-1.5kVA OEM range with GE protocol True entry-level

More information

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications. MGE Galaxy 5000 20/30/40/60/80/100/120 kva The recommended power protection for all critical applications. 20 120 kva state-of-the-art, threephase power protection designed to meet a wide range of requirements

More information

AI561 Analog Input Module

AI561 Analog Input Module Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968

More information

Est FlexiPower Maxi UPS FPX Maxi kVA

Est FlexiPower Maxi UPS FPX Maxi kVA Est.1968 FlexiPower Maxi UPS FPX Maxi 50 250kVA True modular UPS system for critical applications Designed and Published by Thycon. A UPS DESIGNED TO MEET THE NEEDS OF TODAY AND TOMORROW The FlexiPower

More information

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) MODEL NUMBER: SU80KX Highlights 80,000 VA (80kVA) 3-phase tower UPS N+1 redundant modular

More information

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd. Quality Power Supply SENTRY MPS is an on-line double conversion (VFI SS 111 in accordance with IEC EN 620406-3) with a transformer isolated inverter. With a compact footprint and high power quality output,

More information

DC561, digital input/output module,

DC561, digital input/output module, Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,

More information

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact Characteristics variable speed drive ATV320-0.75kW - 200...240V - 1 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

LOW POWER PLA SERIES. Interfaces. Electronic DC Loads

LOW POWER PLA SERIES. Interfaces. Electronic DC Loads Electronic DC Loads LOW POWER PLA SERIES The electronic loads of PLA series combine the classic design of large, easy-to-read displays with modern interfaces and a wide range of functions. The devices

More information

MODULAR DC POWER SUPPLY MODEL 62000B SERIES MODEL 62000B SERIES. Modular DC Power Supply. Ethernet. Key Features :

MODULAR DC POWER SUPPLY MODEL 62000B SERIES MODEL 62000B SERIES. Modular DC Power Supply. Ethernet. Key Features : Modular DC Power Supply MODEL 62000B SERIES Key Features : Voltage range: 1 ~ 150V Current range: Up to 2000A (System) Power range up to 1.5KW per module up to 120KW per system High Power Density (464

More information

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

AO561 Analog Output Module

AO561 Analog Output Module Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal

More information

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw Unique, fully modular and redundant solution The solution for > Computer rooms > Data centres > Banks > Healthcare facilities > Insurance > Telecom Advantages > Ensures absolute business continuity > Aligns

More information

Energy Management Modular Energy meters Type EM2-96

Energy Management Modular Energy meters Type EM2-96 Energy Management Modular Energy meters Type EM2-96 Product Description µp-based modular energy meter with a built-in configuration key-pad. The energies are both partial and total counted. The housing

More information

Kohler EW 6000TX. Transformer-based. (UPS kVA)

Kohler EW 6000TX. Transformer-based. (UPS kVA) (UPS 10 600kVA) Three-phase UPS for computer rooms, data centres, precision instruments, and industrial processes. 10 200 kva PF = 0.9 Small footprint High effciency 92% All series touchscreen design Galvanic

More information

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU40K Highlights 40,000 VA (40kVA) tower UPS with 2 hot-swappable power modules N+1 redundant

More information

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6 Product Description LanPro 31 Contents: 1. Introduction...2 2. Functional explanation...2 2.1 Principles of Operation...2 2.2 Normal Conditions...3 2.3 Mains Failure...3 2.4 Bypass operation...4 3. External

More information

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY COMPREHENSIVE INSTRUMENT FOR MEASUREMENT AND CONTROL OF POWER SYSTEMS CENTRAX CU-SERIES CENTRAX CU3000 CENTRAX CU5000 PAGE 2 Comprehensive instrument for measurement

More information

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module MODEL NUMBER: SV20KS1P0B Highlights Scalable capacity up

More information

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions Online UPS 1,2,3,6,10,20 kva single/single-phase and three/single-phase High Power Intensity STRONGEST PERFORMANCE Flexibility High efficiency with low heat dissipation EXTENDABLE AUTONOMY Smart Energy

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9) Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 370 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application

More information

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES FEATURES 2kW output power Output voltages from 20V to 300V High Packing Density - 2kW in 1U Parallel/series operation Stackable, cooling is front to rear Active Power Factor Correction Custom options available

More information

ATV1200A kv kva

ATV1200A kv kva Characteristics medium voltage variable speed drive ATV1200-10 kv - 5000 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application

More information

ATV1200A kv kva

ATV1200A kv kva Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 3500 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application

More information

Multi Power x 42 kw up to 1 MW + redundancy 3:3 VFI TYPE. Utmost Availability Ultimate Scalability Unmatching Power Density

Multi Power x 42 kw up to 1 MW + redundancy 3:3 VFI TYPE. Utmost Availability Ultimate Scalability Unmatching Power Density DATACENTRE TRANSPORT Multi Power VFI TYPE ONLINE 3:3 Modular 1-28 x 42 kw up to 1 MW + redundancy 6 USB plug SmartGrid ready HIGHLIGHTS Utmost Availability Ultimate Scalability Unmatching Power Density

More information

DC562, digital input/output module,

DC562, digital input/output module, Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE

More information

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W Characteristics motion servo drive - Lexium 28 - single and three phase 200...230 V - 750 W Main Range of product Lexium 28 Product or component type Device short name Format of the drive Line current

More information

AI531 Analog Input Module

AI531 Analog Input Module Ordering Data DATA SHEET AI531 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 600 R0001 AI531, analog input module, 8 AI, U/I/Pt100, TC, 15 bits + sign, 4-wires

More information

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model). SCEE AR 3 - Smart Analyzer 485/Ethernet with web visualization Three-phase electricity meter with instantaneous reading of electrical variables. System variables: V, A, kw, kva, kvar, PF and Hz. Variables

More information

Liebert GXT MT kva

Liebert GXT MT kva Liebert GXT MT+ 10-20 kva Liebert GXT MT+ UPS, 10 kva - 20 kva Intelligent, Reliable UPS Protection Liebert GXT MT+ is a true on-line UPS that delivers continuous, high-quality AC power to connected equipment

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) A55-00017 SEC PLUS 8-10 KVA MAREKTING SPECS REV. A 9/10 8kVA, 10kVA POWERVAR Isolated On-Line UPS Specifications Index 1.0 General

More information

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America MODEL NUMBER: SU80KTV Highlights 80,000 VA (80kVA) tower UPS with 4 hot-swappable power

More information

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES SD700 SERIES is the core of the family, available from 1.5kW to 2200kW [1], a voltage range from 230VAC to 690VAC and available 6, 12, 18 and

More information

Series Watt DC Power Supplies

Series Watt DC Power Supplies Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Series 2268 850-Watt DC Power Supplies Specifications SPECIFICATION CONDITIONS This document contains