CooLinkNet CooLinkNet PRM CooLinkNet Universal Interface Adapter for HVAC Split Systems

Size: px
Start display at page:

Download "CooLinkNet CooLinkNet PRM CooLinkNet Universal Interface Adapter for HVAC Split Systems"

Transcription

1 CooLinkNet Universal Interface Adapter for HVAC Split Systems Document Revision 0.4 /5/06

2 Contents Table of Contents Document Revision History 4 Acronyms 5 3 Outlines 6 3. Layout Models Connectivity 4. HVAC Lines Connection Diagrams... 9 CooLinkNet FJ CooLinkNet ST CooLinkNet MT RS3 Port Ethernet... IP Server. 4.5 RS USB Power General Protocol... 3 Definitions Messaging Exit Code UID Commands Reference... 4 Configuration Commands. set line ifconfig boot HVAC Status and Control. Commands on off cool heat fan dry auto temp fspeed

3 filt stat ls query swing iset feed eco 6 ModBus RTU Contents ModBus Address... 8 Map

4 Document Revision History 4 Document Revision History CooLinkNet FJ Rev 0.3 CooLinkNet DK CooLinkNet ST Rev 0. Meitav-tec models supported: CTU BT, CTU4500 H3 WS, CTU450 CP IRD 05, CTU450 IRD 05, FMH4850 Rev 0. Preliminary

5 DTE GPIO HVAC N.C. TBD Acronyms 5 Acronyms Data Terminal Equipment General Purpose Input/Output Heating Ventilation and Air Conditioning Not Connected To Be Defined

6 3 Outlines 6 Outlines 3. Layout () - Mini USB Device Connector Used to connect CooLinkNet to PC USB Host for FW Update and maintenance. () - RS3/IO Connector Pin Number Pin Name RS3_TX RS3_RX VDCGPIO GPIO Function RS3 Transmit RS3 Receive Ground General Purpose IO General Purpose IO (3) Power, HVAC, ModBus Connector Pin Number Pin Name VDC+ VDCHVAC HVAC MOD_A MOD_B Function Input Voltage Ground HVAC Line L / L4 ModBus A(+) Terminal / HVAC Line L3 ModBus B(-) Terminal / HVAC Line L3

7 Outlines 7 (4) I/F Connector RJ Interface connector (5) ETH Connector RJ45 Ethernet connector 3. Models Model HVAC Manufacturer CooLinkNet ME Mitsubishi Electric CooLinkNet DK Daikin CooLinkNet ST Daikin CooLinkNet FJ Fujitsu/General CooLinkNet TD Tadiran CooLinkNet MT Meitav Lines Number Name L4 L3 L L4 L3 L L4 L3 L4 L3 L L4 L3 L L3 MM ModBus* MAC PP ModBus* KRP ST ModBus* FUS/GEN ModBus* TI (Inverter) TAD (Split) ModBus* MT(Meitav-tec) ModBus* ModBus* - Modbus RTU Slave for DTE integration.

8 4 Connectivity 8 Connectivity 4. HVAC Lines Depending on the specific CooLinkNet model it supports up to four HVAC Lines denoted as L, L, L3, L4. Below tables describes relation between physical connections and HVAC Line numbers. CoolLinkNet ME CooLinkNet ME Indoor Unit Manufacturer Mitsubishi Electric HVAC Line Connectors Terminals RS3 /IO VDC+ TB6 No Polarity CN05 VDC- HVAC HVAC MOD A MOD B I/F (RJ) wires Name L4 (TB6) L (CN05) MM MAC CoolLinkNet DK CooLinkNet ME Indoor Unit Manufacturer Daikin HVAC Line Connectors Terminals RS3 /IO VDC+ P P No Polarity S VDC- HVAC HVAC MOD A MOD B I/F (RJ) wires Name L4 (P P) L (S) PP KRP CoolLinkNet ST CooLinkNet ME Indoor Unit Manufacturer Terminals Daikin Siesta HVAC Line Connectors RS3 /IO VDC+ VDC- HVAC HVAC MOD A MOD B I/F Name (RJ) BRC5A6 RCV GND +5V TX Indoor Socket L4 ST CooLinkNet FJ CooLinkNet FJ Indoor Unit Manufacturer Fujitsu/ General Terminals RS3 /IO RED BLACK WHITE HVAC Line Connectors VDC+ VDC- HVAC HVAC MOD A MOD B I/F (RJ) Name L4 FUS/GEN CooLinkNet TD

9 Terminals RS3 /IO 9 CooLinkNet TD Indoor Unit Manufacturer Connectivity HVAC Lines Connectors VDC+ VDC- HVAC HVAC MOD A MOD B I/F (RJ) Name Tadiran Inverter RED BLUE YELLOW GREEN L TI Tadiran Split RJ L4 TAD CooLinkNet MT CooLinkNet ME Indoor Unit Manufacturer Meitav-tec Terminals RS3 /IO HVAC Line Connectors VDC+ VDC- HVAC HVAC MOD A MOD B I/F (RJ) A(+) B(-) Name L MT 4. Connection Diagrams 4.. CooLinkNet FJ Connection of the original Fujitsu/General wired remote controller is optional. Connection of the CooLinkNet with APG or compatible wired remote controller Connection of the CooLinkNet with EZ-099CWSEFR or compatible wired remote controller

10 Connectivity 0 Indoor Unit power reset required after connecting CooLinkNet or wired remote controller. 4.. CooLinkNet ST Connection of the original BRC5A6 wired remote controller is optional 4..3 CooLinkNet MT Meitav-tek controllers are operated via Modbus interface. In this case CooLinkNet acts as a Modbus master. On CooLinkNet side connection should be done via HVAC and HVAC terminals. CooLinkNet Terminal Meitav-tek Terminal HVAC A HVAC B

11 Connectivity CooLinkNet MT supported models: Meitav-tec Model CooLinkNet FW version CTU BT CTU4500 H3 WS CTU450 CP IRD 05 CTU450 IRD 05 FMH485-0 CTU450 C H3 0 BT CTU450 CP H3 0 BT CTU4500 3S FC SUPER CTU4500 H CTU450/CTU80-CP-HP (via scan 3) 0..0 (via scan 4) 4.3 RS3 Port RS3 Interface in CooLinkNet is available from the RS3/IO connector. Adapter cable (if provided) will route RS3 signals to DB9 connector according to the table below RS3/IO Pin DB9 Pin Signal Lvel Description ±V ±V GND TxD Data from CooLinkNet RxD Data to CooLinkNet Ground Maximal length of the RS3 Cable should not exceed 5m. The default CooLinkNet RS3 Port settings are: Baud Rate Data Bits Parity Control Stop Bits Flow Control None None By default RS3 Interface is dedicated for protocol.

12 Connectivity 4.4 Ethernet CooLinkNet incorporates an IEEE 80.3 compatible 0/00 Mb/s Ethernet port supported via RJ45 connector. Below are main port features. Parameter Value Notes Max Ethernet Cable Length 37m CAT5 twisted pair cable Bit Rate 0/00 Mb/s Supported Ethernet Protocols 0BASE-T/00BASE-TX Protocol Auto-Negotiation Enabled Against Link Partner RJ45 connector comprises Link and Activity indication LEDs used as specified below. LED Color Function Link Led Green ON for good link OFF for no link Activity Led Orange BLINK for Tx/Rx Activity Ethernet interface is used by a number of protocol modules available in CooLinkNet (via IP Server) CoolRemote Network setting of the CooLinkNet are controlled with ifconfig command IP Server IP Server referenced as aserver is a classic TCP/IP socket server. Aserver has the following default characteristics: Maximal number of simultaneous connections Default TCP/IP port RS485 By default terminals MOD A and MOD B (Line L3) are used as an RS485 Interface line for DTE connection. CooLinkNet supports the following RS485 based protocols: ModBus RTU (Slave mode) 4.6 USB CooLinkNet incorporate USB Device port. USB Device port is used for maintenance operations. 4.7 Power CooLinkNet depending on the specific model type can be powered from different power sources: AC/DC adapter via VDC+ and VDC- terminals -4V DC from HVAC or other equipment via VDC+ and VDC- terminals USB Device port

13 5 3 CooLinkNet provides simple and comprehensive Protocol, based on text (ASCII) strings, representing verbal commands and responses. implemented in CooLinkNet is fully backward compatible with previous versions of CooLink products line, but has a number of significant extensions and improvements mainly aimed to support additional CooLinkNet functionality. can be utilized via RS3 interface (see RS3 Port) or TCP/IP ASCII Server. 5. General Protocol Definitions 5.. Messaging Communication between DTE and CooLinkNet via is based on text (ASCII) strings. Communication example is shown below çcommand ls L L.0 OFF 0C 7C Auto Cool L.03 OFF 0C 4C Low Auto çresponse çexit code çprompt DTE to CooLinkNet CooLinkNet to DTE Command string sent to CooLinkNet must be terminated with <CR (carriage return 0x0D) <LF (line feed 0x0A) sequence or a single <CR character. Strings from CooLinkNet (except prompt character) are always terminated with <CR <LF. Commands are case sensitive and should not contain leading or trailing spaces. The only separator between command name and command parameter(s) is space (0x0) character. Configuration parameter echo (see set command), defines if characters sent to CooLinkNet via RS3 interface are echoed back or not. If echo is not zero - characters are echoed. In case of RS3 interface, prompt character '' is unconditionally sent by CooLinkNet. In case of ASCII Server prompt sending is configurable. 5.. Exit Code CooLinkNet provides Exit Code in verbose or numeric form. Numeric form format is ERROR:N where N is a number in range If verbose format is not specified in table below it means error has only numeric format. Numeric Verbose Bad Format Failed Line Unused Unknown Command Bad Parameter, Boot Required! Description Command executed successfully UID not found UID must be precise Command format is wrong Command execution failed Line is unused Command is unknown Line number is wrong Wrong function Command parameter is wrong Command execution will be effective after reboot

14 UID UID is used to identify Indoor Unit or a set of Indoor Units. UID has the following format: Line LN Dot. Indoor Number X YY Line is a CooLinkNet HVAC Line number in range L..L4. L* means "any line". In some cases to provide backward compatibility Line can be omitted from the UID. Dot is a separator between Line and Indoor Number. If Line is omitted or has a L* form, dot must also be omitted. Indoor Number is an Indoor Unit number in HVAC system. Indoor Number can be '*' that means "any" Examples: L.0 L.003 L*00 L3.* L4 L* 03 Indoor Unit 0 on line L Indoor Unit 003 on line L Set of Indoor Units 00 on all lines Set of Indoor Units xx on line L3 (L3.00, L3.0,... ) All Indoors on line L4 All Indoors on all lines Similar to L*03 (for backward compatibility only) 5. Commands Reference Synopsis and description of the commands listed below have the following notation: Parameters or parameters group in angle brackets < are mandatory. Parameters or parameters group in square brackets [ ] are optional and can be omitted. The curly braces ( ) are used to denote group inside braces The character between parameters inside brackets means OR. 5.. Configuration Commands set line ifconfig set set [<SETTING <VALUE] set defaults Query or change CooLinkNet setting(s). Without parameters set command will list all supported settings and their values. To change setting use format with <SETTING and <VALUE. Some settings are read only (RO) and can not be changed. set defaults will load default values to all settings <SETTING S/N version Mode RO RO Printed as S/N version Value* X.Y.Z Description CooLinkNet Serial Number CooLinkNet Firmware Version

15 RW app baud echo verbose aserver port aserver prompt deg RW RW RW RW RW RW application baud rate echo verbose aserver port aserver prompt deg C/F 5 string CooLinkNet Application RS3 Interface baud rate. Default: or RS3 Interface echo control. 0 - disabled, - enabled 0 0r Exit Code format. 0 - numeric, - verbose integer aserver TCP port. Default: 00 0 or aserver prompt control C or F Temperature scale Celsius or Fahrenheit * - Bold values are defaults. Disable echo: set echo 0 Change aserver TCP port: set aserver port 345 Load defaults: set defaults line line line <PROPERTY <Ln <VAL Query or change HVAC Lines status and configuration. In format without parameters line command will provide information about current Lines status. Second format is used to change write enabled properties. <PROPERTY master Mode Value R/W simul R/W myid R/W baud R/W Tx Rx TO CS Col NAK RO RO RO RO RO RO Description 0 or CooLinkNet acts as a Master device Notes FUS,MM only integer Simulate given number of Indoor Units. To disable simulation use "0". Simulation is persistent (not disabled after power reset) CooLinkNet Own address on given HVAC Line. For ModBus RTU Line myid is a "Slave Device Address" Configure UART parameters for given Line. Value format is: <BAUD <8 9<N E O< For example: N integer Transmitted messages counter Received messages Timeout errors Checksum errors Collision errors NAK errors string Where applicable Printed as Total/Last Last means since previous print

16 ambtemp WO 0 or Ambient temperature in Slave mode is taken from: 0 - Master device - Indoor return air 6 MM only line L: Unused Tx:0/0 Rx:0/0 TO:0/0 CS:0/0 Col:0/0 NAK:0/0 L: TI U00/G00 Tx:40/40 Rx:0/0 TO:39/39 CS:0/0 Col:0/0 NAK:0/0 L3: CLMB Address:0x50(80) 9600_8N Tx:0/0 Rx:0/0 TO:0/0 CS:0/0 Col:0/0 NAK:0/0 L4: FUS Slave U00/G00 Not Connected Tx:0/0 Rx:0/0 TO:0/0 CS:0/0 Col:0/0 NAK:0/0 Become Slave on Line L4 line master L4 0, Boot Required! Set Line L3 baud rate to 900, 8 data bits, even parity, stop bit line baud L E, Boot Required! ifconfig ifconfig ifconfig <PROPERTY <VALUE ifconfig enable disable Query or configure Ethernet network settings. Without parameters, ifconfig command will list current configuration. To change configuration use format with <PROPERTY and <VALUE. Parameter IP can be set to DHCP (DHCP client) or fixed IP number. In case of DHCP - Netmask and Gateway values are provided by DHCP server. By default CooLinkNet is configured for DHCP client operation. CooLinkNet Ethernet module can be enabled or disabled with corresponding command. Query ifconfig MAC : 8:3B:96:FF:FF:FE Link : Up IP : (DHCP) Netmask: Gateway:

17 7 Configure fixed IP and Gateway ifconfig IP , Boot Required! ifconfig Gateway , Boot Required! Configure DHCP client operation ifconfig IP DHCP Disable Ethernet ifconfig disable, Boot Required! boot boot boot [N] <N omitted - Enter Boot Mode <N = - Reset CooLinkNet 5.. HVAC Status and Control Commands on off cool heat fan dry auto temp fspeed swing filt stat ls query iset feed eco on on [UID] Turn on Indoor Unit(s).

18 8 Turn on Indoor Unit 0 on line L on L.0 Turn on all Indoor Units on Line L on L* off off [UID] Turn off Indoor Unit(s). Turn on Indoor Unit 0 on line L off L.0 Turn on all Indoor Units on line L off L* cool cool [UID] Set Indoor Unit(s) operation mode to cool. Set Indoor Unit 0 on line L to cool mode cool L.0 Set all Indoor Units on line L to cool mode cool L*

19 9 heat heat [UID] Set Indoor Unit(s) operation mode to heat. Set Indoor Unit 0 on line L to heat mode heat L.0 Set all Indoor Units on line L to heat mode heat L* fan fan [UID] Set Indoor Unit(s) operation mode to fan. Set Indoor Unit 0 on line L to fan mode fan L.0 Set all Indoor Units on line L to fan mode fan L* dry dry [UID] Set Indoor Unit(s) operation mode to dry. Set Indoor Unit 0 on line L to dry mode dry L.0 Set all Indoor Units on line L to dry mode

20 0 dry L* auto auto [UID] Set Indoor Unit(s) operation mode to auto. Set Indoor Unit 0 on line L to auto mode auto L.0 Set all Indoor Units on line L to auto mode auto L* temp temp [UID] [±]<TEMP temp [UID] <TEMP.d Change Indoor Unit(s) Set Temperature. In form temp <UID [±]<TEMP <TEMP parameter must be decimal natural number. Command can work in relative or absolute manner. If plus '+' or minus '-' sign precedes <TEMP parameter it's value will be added to or substituted from current Set Temperature value. Otherwise Set Temperature will be set to the given <TEMP value. In form temp <UID <TEMP.d Set Temperature parameter <TEMP.d is a fractal number with 0. precision. (In this case preceding + - are not allowed). If HVAC System does not support 0. precision for the Set Temperature (see table below), the final value will be nearest supported value. AC Type DK ME Set Temperature Precision 0.ºC 0.ºC The deg setting (see set command) defines which temperature scale Celsius or Fahrenheit is used for <TEMP and <TEMP.d parameters value. Set Indoor Unit 0 on line L Set Temperature to 3º

21 temp L.0 3 Decrease all Indoor Units on line L Set Temperature by º temp L* - Set all Indoor Units on line L Set Temperature to 4.5º temp L* 4.5 fspeed fspeed [UID] <l m h t a Set Indoor Unit(s) Fan Speed to: l - low m - medium h - high t - top a - auto Not all Indoor Units support Fan Speed options listed above. Specific Fan Speeds support depend on specific Indoor Unit capabilities. If requested Fan Speed is not supported by Indoor Unit(s) fspeed command will have no effect. Set Indoor Unit 0 on line L Fan Speed to low fspeed L.0 l Set all Indoor Units on Line L Fan Speed to high fspeed L* h filt filt <UID Reset Filter Sign. Reset Filter Sign on Indoor Unit 0 0n line L on L.0

22 Reset Filter Sign on all Indoor Units on Line L on L* stat stat [UID] stat [UID] stat3 [UID] stat4 [UID] Get Indoor Unit(s) status list. These commands are deprecated and are not recommended for use in CooLinkNet. They are implemented for backward compatibility only. Detailed description of these commands can be found in the PRM of previous CooLink versions. ls ls [UID] Get Indoor Unit(s) status list. If UID is omitted all Indoor Units connected to CooLinkNet will be listed. Indoor Unit status line has strict format, so that every status field is printed in fixed position. Indoor Unit status line with Celsius temperature scale L.0 OFF 0C 7C High Cool - 0 Indoor Unit status line with Fahrenheit temperature scale L.0 OFF 0F 7F High Cool - 0 Field UID On/Off Set Temperature Room Temperature Fan Speed Operation Mode Indoor Failure Code Filter Sign Demand Position in string Celsius Fahrenheit Values LN.XYY ON,OFF nnc or nnnf nnc or nnnf Low, Med, High, Top, Auto Cool, Heat, Fan, Dry, Auto - no failure, else Indoor Failure Code - or # (Filter Sign) 0 or ls L

23 L.0 ON L.0 OFF ls L.0 L.0 ON ls L.0 ON L.0 ON L.0 ON L.0 OFF 5C 7C Low Cool 0C 7C High Cool C 7C Low Cool - 5C C 5C 0C Cool Cool Cool Cool - 4C 3C 7C 7C Low Med Low High query query <UID_STRICT <o m f t h e a s Query one of the operation conditions of given Indoor Unit. <UID_STRICT parameter must define single Indoor Unit in form LN.XYY or XYY (see UID). Resulting value is printed as alpha-numeric value according to the table below. Query o m Operation Condition On/Off Operation Mode f Fan Speed t e Set Temperature Failure Code a h s Ambient Temperature Set Temperature Louver Position Value 0 - Off, - On 0 - Cool - Heat - Auto 3 - Dry 4 - Haux 5 - Fan 0 - Low - Medium - High 3 - Auto 4 - Top Natural 0 - No failure, otherwise failure code same as in ls command Natural 0.0º Precision 0 - No Louver Control a - auto (swing) h - horizontal 3-30º 4-45º 6-60º v - vertical query L.00 o

24 query 0 query 5 query 7 query query U4 query 0 query L.00 m L.00 t L.00 a L.00 f L.00 e L.00 e L.00 h swing swing <UID <h v a Set Indoor Unit(s) louver position to: h - horizontal v - vertical a - auto (swing) 3-30º 4-45º 6-60º Not all Indoor Units support louver position options listed about or have louver position control at all. Louver control is capability of the specific Indoor Unit type. If requested louver position is not supported by Indoor Unit(s), swing command will have no effect. Set Indoor Unit 0 on line L louver to horizontal position swing L.0 h iset iset <UID <SETN iset <UID <SETN <VAL

25 5 Read/Write Indoor Unit internal parameter (setting). If value not specified the parameter is read otherwise it is written with <VAL and read back. Below is the list of the most useful settings. <SETN 0 Function Ambient Temperature 05 Auto Mode Mode Value Description MM (Mitsubishi Electric) Average R/W Indoor Unit return air sensor 3 Wired Thermostat sensor Enabled R/W Disabled FUS (Fujitsu) 4 Ambient Temperature R/W 48 Ambient Temperature with Wired Thermostat R/W 0 0 Indoor Unit sensor only Depends on setting 48 Indoor Unit and Wired Thermostat sensors Wired Thermostat sensor only The complete up-to-date information about internal parameters and their values should be taken from related manual of the specific HVAC system and Indoor Unit type. Information in above table is provided only for reference. COMPATIBILITY MM TAD FUS Yes N.A. Yes feed feed <Ln [±]<TEMP[.d] This command defines CooLinkNet Own Ambient Temperature (as if it were measured by CooLinkNet itself). Command can work in relative or absolute manner. If plus '+' or minus '-' sign precedes <TEMP parameter it's value will be added to or substituted from current value. Otherwise Own Ambient Temperature will be set to the given <TEMP value. <TEMP can be provided with 0. precision. If <TEMP is zero CooLinkNet will not use Own Ambient Temperature for it's operation. CooLinkNet keeps separate Own Ambient Temperature for each HVAC Line. If <Ln is omitted the first not "Unused" HVAC Line will be taken. Own Ambient Temp usage depends on HVAC Line type. HVAC Line Own Ambient Temp usage MM If non zero, sent to Indoor Unit as Wired Thermostat temperature sensor value FUS TAD Temperature sent to Indoor Unit in i-feel message feed 4.5 L

26 6 eco eco [UID]<0 Turns off - 0 or on - ECO (economy) mode on Indoor Unit(s). Turn on ECO mode on Indoor Unit 0 on line L eco L.0 COMPATIBILITY MM TAD FUS N.A. N.A. Yes

27 6 ModBus RTU 7 ModBus RTU CooLinkNet is fully compliant with following ModBus specifications: MODBUS over Serial Line Specification and Implementation Guide V.0 MODBUS application protocol specification V.b ModBus Interface Physical Layer CooLinkNet physical connection to ModBus is Two-Wire EIA/TIA-485 standard interface via 485-A and 485-B terminals, recommended by ModBus specification. On such W-bus, at any time only one driver has the right for transmitting thus a ModBus communication is always initiated by the master. CooLinkNet will never transmit without receiving a request from master. A number of CooLinkNet devices can be connected to single W-bus. Each CooLinkNet in this case must have unique ModBus slave address (command line myid <Ln <VAL). ModBus RTU Frame Format CooLinkNet by default supports ModBus RTU Transmission Mode with following frame format: Baud Rate Start Bits Data Bits Parity Stop Bits No Frame format can be changed with line baud <Ln <VAL command. Supported MODBUS Functions Function Code 03 (0x03) 06 (0x06) 6 (0x0) 43 4 (0xB 0x0E) Function Description Read Holding Registers Write Single Register Write Multiple registers Read Device Information

28 ModBus RTU 8 6. ModBus Address Map Holding Reg Address* Description Read Write Hex Dec CooLinkNet Internals CooLinkNet Version CooLinkNet S/N CooLinkNet Model ModBus Address Reset W R Internal State 0 - Not Connected to RC line - Connecting - Connected as single RC 3 - Connected as Master RC. Detected Slave RC 4 - Connected as Slave RC 0 - Master Mode (default) - Slave Mode UID Indoor Status and Control On/Off 0-Off, -On Operation Mode (see Mode Encoding ) Fan Speed (see Fan Speed Encoding ) Set Point C Failure Code Indoor Ambient Temperature C 00 7 Feed Temperature C Required** R R R RW RW R R R R R Notes Version Model Major*00 + Minor*0 + SubMinor Lower 6 bit Two ASCII characters ModBus Address change is effective only after reset - Enter Boot mode CooLinkNet does not respond to the write request into this register - Reset MSB - X, LSB - YY W W W W R R MSB - Integer Part LSB - Fraction Part * 0.0 RW *On the ModBus wire registers address range starts from 0 and thus register address is sent decremented (-). ** If Version or Model is not specified, it means that register is supported in any CooLinkNet version and/or model. N.A. means future option. Mode Encoding Cool 0 Heat Auto Dry 3 Haux 4 Fan 5 Fan Speed Encoding Low 0 Medium High Auto 3 Top 4

PRELIMINARY. CoolMasterNet PRM. CoolMasterNet Universal Interface Adapter for HVAC Systems. Document Revision /11/2014

PRELIMINARY. CoolMasterNet PRM. CoolMasterNet Universal Interface Adapter for HVAC Systems. Document Revision /11/2014 CoolMasterNet PRM CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.4 12/11/2014 CoolMasterNet PRM Contents 2 Table of Contents 1 Document Revision History 4 2 Acronyms 5 3

More information

CooLinkHub PRM. CooLinkHub Universal Interface Adapter for HVAC Split Systems. Document Revision /09/2017

CooLinkHub PRM. CooLinkHub Universal Interface Adapter for HVAC Split Systems. Document Revision /09/2017 CooLinkHub PRM CooLinkHub Universal Interface Adapter for HVAC Split Systems Document Revision 1.0 23/09/2017 www.coolautomatiom.com 2017 Contents Table of Contents 1 Revision History... 4 2 ACRONYMS...

More information

CoolMaster Programmers Reference Manual (PRM)

CoolMaster Programmers Reference Manual (PRM) CoolMaster Programmers Reference Manual (PRM) CoolMaster Interface Adapter for VRV, VRF Air Conditioning Systems Cool Master 1000D Cool Master 2000S Cool Master 3000T Cool Master 4000M Version 3.0 8/12/2009

More information

CoolMasterNet CooLinkNet CooLinkHub CooLinkBridge. BACnet Integration Guidelines. BACnet Integration Guidelines

CoolMasterNet CooLinkNet CooLinkHub CooLinkBridge. BACnet Integration Guidelines. BACnet Integration Guidelines BACnet Integration Guidelines CoolMasterNet CooLinkNet CooLinkHub CooLinkBridge BACnet Integration Guidelines Document Revision 0.2 Thursday, June 14, 2018 BACnet Integration Guidelines Contents 2 Table

More information

ThermoPad Reference Manual

ThermoPad Reference Manual ThermoPad Reference Manual Revision 0.6 www.coolautomation.com 2/18/2015 2 Table of Contents 1 Revision History 3 2 Specification 4 3 Thermopad Models 5 4 Terminals 6 5 MODBUS Map 7 6 Special Features

More information

CoolMasterNet CooLinkNet. HDL Integration Guidelines. HDL Integration Guidelines

CoolMasterNet CooLinkNet. HDL Integration Guidelines. HDL Integration Guidelines HDL Integration Guidelines CoolMasterNet CooLinkNet HDL Integration Guidelines Document Revision 0.1 12/27/2015 HDL Integration Guidelines Contents 2 Table of Contents 1 Connection 3 2 Configuration 4

More information

KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems

KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems Document Revision 0.5 5/30/2018 Attention 1. During the HVAC system automatic operations the CoolMasterNet must be disconnected

More information

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide CoolPlug CooLinkHub HVAC Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in

More information

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning Installation and User Guide www.microtrol.co.uk Contents 1. Supplied Parts...2 2. Important Information...3 3. Product Overview...4

More information

Venstar Thermostat Adapter

Venstar Thermostat Adapter Developer Venstar Thermostat Adapter v001 Developer Venstar Thermostat Adapter Version 001 May 23, 2013 Revision History Rev Date Comments 001 05/23/13 Initial Release Page 1 of 13 Table of Contents 1

More information

KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems

KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems Document Revision 0.4 9/8/2017 Attention 1. During the HVAC system automatic operations the CoolMasterNet must be disconnected

More information

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation. Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4

More information

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4

More information

CAN / RS485. Product Description. Technical Reference Note. Interface Adapter. Special Features

CAN / RS485. Product Description. Technical Reference Note. Interface Adapter. Special Features CAN / Interface Adapter For SHP Series Total Power: < 1 Watts Input Voltage: 5V Internal Outputs: CAN,, USB, I 2 C Special Features Input Protocols: 1) using Modbus 2) CAN using modified Modbus Output

More information

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017

More information

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng IntesisBox Modbus Server LG Air Conditioning User s Manual Issue Date: 06/2016 r1 eng Intesis Software S.L. 2016 All Rights Reserved. Information in this document is subject to change without notice. The

More information

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter Bluetooth V4.1 BLE RS-232 Serial Adapter 1. Package content: BLE RS-232 adapter Model: BLE-232B Package Contents: BLE RS-232 adapter x 1 Screw x2, Screw nut x 2 A4 User manual x 1 Mini USB Cable x 1 White

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide. MXM-50 Modbus Interface for Mitsubishi Air-Conditioning Installation and User Guide www.innon.co.uk 1. Product Overview The Black Pear MXM-50 unit allows a Modbus building management system (BMS) to monitor

More information

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in injury or death. This equipment

More information

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter 1. Package content: BLE RS-232 adapter Bluetooth V4.2 BLE RS-232 Serial Adapter Model: BLE-232D-E Package Contents: BLE RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box: 11 x 6 x 5 (cm)

More information

EGW1-IA3-MB User s Manual

EGW1-IA3-MB User s Manual www.exemys.com Rev. 0 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information

More information

Winsonic MODBUS Remote IO user manual Rev. 1.0

Winsonic MODBUS Remote IO user manual Rev. 1.0 Winsonic MODBUS Remote IO user manual Rev. 1.0 Model: LEGAL NOTICE Warranty All products manufactured by Winsonic are under warranty regarding defective materials for a period of one year, beginning from

More information

Modbus Server - Mitsubishi Electric G50

Modbus Server - Mitsubishi Electric G50 IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel )

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

Installation Manual. DZK BACnet

Installation Manual. DZK BACnet Installation Manual DZK BACnet InterfacepbilCodarPageNumber TABLE OF CONTENTS Page Overview... 5 Outline and Features... 5 System outline... 5 Specifications and device elements... 6 Functional specifications...

More information

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-422/485 Serial Adapter. Model: BLE-485C. 1. Package content: BLE RS-422/485 adapter

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-422/485 Serial Adapter. Model: BLE-485C. 1. Package content: BLE RS-422/485 adapter Bluetooth V4.2 BLE RS-422/485 Serial Adapter 1. Package content: BLE RS-422/485 adapter Model: BLE-485C Package Contents: BLE 422/485 adapter x 1 Screw x2, Screw nut x 2 A4 User manual x 1 Mini USB Cable

More information

Installation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC

Installation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC Installation Instructions Procon IP-32M 2371-wir-1_2-0204 MITSUBISHI ELECTRIC Procon IP-32M Overview The Procon IP-32M unit provides an interface between a Mitsubishi City-Multi G50A controller with up

More information

ABLELink. Modbus Gateway MB5000 Series User s Manual

ABLELink. Modbus Gateway MB5000 Series User s Manual ABLELink MB5000 Series User s Manual Version 1.1 Updated in March, 2010 TEL: 886-3-5508137 FAX: 886-3-5508131 http://www.atop.com.tw Table of Contents Table of Contents... 2 Introduction... 4 Features...

More information

RTD-NET Installation Instructions

RTD-NET Installation Instructions LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND

More information

Ethernet to RS-232/485 Gateway

Ethernet to RS-232/485 Gateway Ethernet to RS-232/485 Gateway (Mode: IP-S) Feature: Operation voltage : DC 7V ~ 20V. RS232 Interface Meets or Exceeds TIA/EIA-232-F and ITU Recommendation V.28 Interface : ±12V levels compatibility. Data

More information

Specifications Manual

Specifications Manual TCS-NET MODBUS Model name: TCB-IFMB640TLE Contents 1 System Overview... 2 2 RS 485 Communication Parameters... 3 3 Applied Function Codes... 3 4 Exception Response... 4 5 Counters and Registers... 4 6

More information

Application Note: Using Modbus With the Conext CL Series. Important Safety Instructions

Application Note: Using Modbus With the Conext CL Series. Important Safety Instructions : Using Modbus With the Conext CL Series 976-0317-01-01 Rev A Important Safety Instructions READ AND SAVE THESE INSTRUCTIONS - DO NOT DISCARD This document contains important safety instructions that must

More information

INTERFACE SPECIFICATION

INTERFACE SPECIFICATION INTERFACE SPECIFICATION MODBUS CONVERTOR UTY-VMGX PART NO. 9708438030 Modbus is registered trademarks of Schneider Electric SA. LONWORKS is registered trademark of Echelon Corporation in the United States

More information

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232C

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232C Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232C Package content: BLE RS-232 adapter x 1 Screws for DB9 connector x 2 Nuts for DB9 connector x 2 User

More information

Revision 1.2. July 24, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA

Revision 1.2. July 24, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA Revision 1.2 July 24, 2017 COM Protocol Manual for MDC and ADC www.mountztorque.com - 1080 N 11th St - San Jose CA 95112-408.292.2214 1 1 Overview and Communication Specifications 1.1 Overview If the PC

More information

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners. IntesisBox FJ-RC-MBS-1 v.2.5 Modbus RTU (EIA-485) Interface for Fujitsu air conditioners. User Manual Issue Date: 12/2017 r1.9 EN Order Codes: FJ-RC-MBS-1: Modbus RTU Interface for Fujitsu air conditioners

More information

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway User s Manual www.icpdas.com 1 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one

More information

IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML. User Manual Issue Date: 01/2018 r1.0 EN

IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML. User Manual Issue Date: 01/2018 r1.0 EN IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML User Manual Issue Date: 01/2018 r1.0 EN Intesis Software S.L.U. 2018 All Rights Reserved. Information in this document is

More information

PF MODBUS REGISTER MAP. v1.4 Revised Nov 29, 2016

PF MODBUS REGISTER MAP. v1.4 Revised Nov 29, 2016 PF3107-00 MODBUS REGISTER MAP v1.4 Revised TRADEMARKS AND COPYRIGHT All content is subject to copyright and may not be reproduced in any form without the express written consent of the author. 2016 Profire

More information

Ethernet to Serial Port Module RS-232/422/485 to Internet Gateway

Ethernet to Serial Port Module RS-232/422/485 to Internet Gateway Ethernet to Serial Port Module RS-232/422/485 to Internet Gateway (Model: IPM-S) Wireless Gateway: Active RFID Gateway Bluetooth to Internet Application: Energy Meter Networks Motor Control Industrial

More information

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2 Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2 Package content: BLE RS-232 adapter x 1 Screws for DB9 connector x 2 Nuts for DB9 connector x 2 User

More information

Modbus Server - Mitsubishi Electric G50

Modbus Server - Mitsubishi Electric G50 IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel )

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

WiFi to RS-232 adapter user manual

WiFi to RS-232 adapter user manual WiFi to RS-232 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm) Total Package Weight: 126

More information

IntesisBox ModBus RTU Fujitsu Air Conditioning

IntesisBox ModBus RTU Fujitsu Air Conditioning IntesisBox ModBus RTU Fujitsu Air Conditioning Compatible with Domestic and VRF line air conditioners commercialized by Fujitsu User Manual 03/2019 r1.0 eng Intesis Software S.L.U. 2019 All Rights Reserved.

More information

TRP-C37M User s Manual

TRP-C37M User s Manual TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed May. 2011 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

WiFi to RS-422/485 adapter user manual

WiFi to RS-422/485 adapter user manual WiFi to RS-422/485 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-422/485 adapter x 1 2 dbi dipole antenna x 1 A4 User manual x 1 USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm)

More information

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6. Section Mounting Dimensions / Viewing 2 Mounting Options 3 Section 2 Wiring Configuration 4 Section 3 Quick Set up Procedure 5 Section 4 Changing Intensity 6 Section 5 Option Summary 7 Section 6 Option

More information

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.3 3/23/2015 Attention 1. During the HVAC system automatic operations the CoolMasterNet must be

More information

OEM API Specification

OEM API Specification OEM API Specification For Wasatch Photonics OEM Spectrometers WasatchDevices.com Revised 2016-08-26 Page 1 Revision Log Revision Date By Reason 1.0 2016-08-29 J. Traud Initial Release Contents General

More information

F4T Touch Screen Controller Cascade Control Addendum

F4T Touch Screen Controller Cascade Control Addendum F4T Touch Screen Controller Cascade Control Addendum Revision 3.06 and higher Firmware TestEquity LLC 6100 Condor Drive Moorpark, CA 93021 Support: 877-512-3457 Toll Free 805-480-0638 Corporate: 800-732-3457

More information

DK-AC-KNX-1. Specifications. Main features. Info

DK-AC-KNX-1. Specifications. Main features. Info IntesisBox 2015 DK-AC-KNX-1 IntesisBox DK-AC-KNX-1 allows monitoring and control, fully bi-directionally, all the operational parameters of DAIKIN air conditioners from KNX installations. Compatible with

More information

BMS Interface for Panasonic Air-Conditioning

BMS Interface for Panasonic Air-Conditioning BMS Interface for Panasonic Air-Conditioning Installation and User Guide www.microtrol.co.uk BACnet TM is a registered trademark of ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning

More information

MODBUS COMMUNICATION INSTRUCTIONS

MODBUS COMMUNICATION INSTRUCTIONS SYNC-MODB Rev A MODBUS COMMUNICATION INSTRUCTIONS SYNC Models: 1.0-1.3-1.5 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including

More information

HRM-0800 Instruction Manual

HRM-0800 Instruction Manual HRM-0800 Instruction Manual Table of Contents 1 Highway Addressable Remote Transducer (HART ) 4 2 General Specifications 5 3 Dimensions: 6 4 General Description 7 4.1 Introduction 7 4.2 Purpose 8 4.3 Functions

More information

IntesisBox PA-AW-MBS-1 v.2.0

IntesisBox PA-AW-MBS-1 v.2.0 IntesisBox PA-AW-MBS-1 v.2.0 Modbus RTU (EIA485) Interface for Panasonic Aquarea series. User Manual Issue Date: 08/2014 r2.0 Order Code: PA-AW-MBS-1: Modbus RTU Interface for Panasonic Aquarea series

More information

VPGate Manual PROFIBUS to serial

VPGate Manual PROFIBUS to serial VPGate Manual PROFIBUS to serial Important information Purpose of the Manual This user manual provides information how to work with the VPGate PROFIBUS to serial. Document Updates You can obtain constantly

More information

IntesisBox Modbus Server - BACnet/IP Client

IntesisBox Modbus Server - BACnet/IP Client IntesisBox Modbus Server - BACnet/IP Client Gateway for integration of devices into Modbus (RTU and TCP) systems. Integrate Daikin VRV Air Conditioners into your Modbus system (SCADA, BMS, PLC ). For this,

More information

Ethernet to RS-422/485 adapter user manual

Ethernet to RS-422/485 adapter user manual Ethernet to RS-422/485 adapter user manual Ethernet to RS-485 adapter Package Contents: Ethernet RS-485 adapter x 1 A4 User manual x 1 USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm) Total Package Weight:

More information

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS 1 Introduction... 2 1.1 Scope of this document... 2 2 Abbreviations... 2 3 Context... 3 4 General description... 3 4.1 Protocol description...

More information

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual CAS-2700-42 IKS to Modbus RTU Gateway CAS 2700-42 IKS Gateway (Modbus RTU/TCP and HTML) Manual CAS 2700-42 IKS Gateway Manual Page 1 of 34 BLANK PAGE CAS 2700-42 IKS Gateway Manual Page 2 of 34 Contents

More information

TRP-C37M User s Manual

TRP-C37M User s Manual TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed OCT. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

Serial Connection of HC900 Hybrid Controller to 900CS Control Station Note: Ethernet connections will provide faster performance than RS-485 HC900 1. Remove HC900 CPU and set S2 Dip Switches for RS-485 unterminated Replace CPU & follow instructions per Installation and User

More information

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232DEXA

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232DEXA Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232DEXA Package content: BLE RS-232 adapter x 1 User manual x 1 Mini USB Cable x 1 DB9 (male) Reset to

More information

Integration Note OVERVIEW AND SUPPORTED FEATURES

Integration Note OVERVIEW AND SUPPORTED FEATURES Manufacturer: Model Number(s): KNX Climate (Various) Minimum Core Module g! 5.4 Version: g! 6.2 Minimum for Fan Coil Climate Modes Document Revision Date: 10/8/2015 OVERVIEW AND SUPPORTED FEATURES Integration

More information

WiFi to RS-232 adapter user manual

WiFi to RS-232 adapter user manual User Manual V1.2 Date: 2015.01.28 WiFi to RS-232 adapter user manual Package Contents: WiFi RS-232 adapter x 1 WiFi to RS-232 adapter 2 dbi dipole antenna x 1 A4 User manual x 1 USB Cable x 1 Power cable

More information

Modbus Server - Mitsubishi Electric G50

Modbus Server - Mitsubishi Electric G50 IntesisBox Server - Mitsubishi Electric G50 This communication gateway allows you to supervise and control Mitsubishi Electric City Multi Air Conditioning systems from any modbus master device TCP or RTU,

More information

For more information Contact with details of the application.

For more information Contact with details of the application. Eaton Corporation Telecommunications Power Solutions Email: dc.info@eaton.com www.eaton.com/telecompower Application Note AN0107 SC200 Modbus Server Last updated 20 January 2017 Applicable products SC200

More information

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH485Ex1 Doc No: PH485Ex1-UM-001 #1 RS-485 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation HART / EtherNet/IP Gateway GT200-HT-EI V 1.0 REV A SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 Product Overview... 4 1.1 Product Function...4 1.2 Product Features... 4 1.3 Technical

More information

IntesisBox TO-RC-MBS-1

IntesisBox TO-RC-MBS-1 IntesisBox TO-RC-MBS-1 v.1.5 MODBUS RTU (EIA485) Interface for Toshiba air conditioners from the Digital Inverter & VRF lines. User Manual Issue Date: 01/2014 Order Codes: TO-RC-MBS-1 Intesis Software

More information

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS 1 Introduction... 2 1.1 Scope of this document... 2 2 Abbreviations... 2 3 Context... 3 4 General description... 3 4.1 Protocol description...

More information

Uponor Smatrix Move PRO Controller X-159 Modbus RTU interface

Uponor Smatrix Move PRO Controller X-159 Modbus RTU interface Uponor Smatrix Move PRO Controller X-159 Modbus RTU interface PRODUCT INFORMATION The controller can be connected and integrated to a building management system (BMS) through a Modbus-RTU interface over

More information

SC168MBM 16x8 Characters MODBUS MASTER LCD

SC168MBM 16x8 Characters MODBUS MASTER LCD Product Description SC168MBM is a programmable LCD that serve as MASTER RTU MODBUS device. It reads and display registers values from MODBUS Slave devices through its RS485 port. The LCD can be configured

More information

Flex Series User Guide

Flex Series User Guide User Programmable Current 4..20mA Digital RS485 Dual & Single Axis Up to 360º 2016 Flex Series User Guide Sensor Installation, Wiring, Flexware App Instructions Page 1 of 33 Page 2 of 33 Table of Contents

More information

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8O Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the

More information

Ethernet Interface Module

Ethernet Interface Module Interface Manual 1 Ethernet Interface Module SignalFire Number: ENET-DIN The SignalFire Ethernet Gateway has the following features: - Wide range DC power input. 6 to 36VDC - Power Over Ethernet (POE)

More information

ETOR-4. Ethernet/Serial Gateway USER MANUAL

ETOR-4. Ethernet/Serial Gateway USER MANUAL ETOR-4 Ethernet/Serial Gateway USER MANUAL 1 TABLE OF CONTENTS SECTION 1 GENERAL INFORMATION...6 SECTION 2 INSTALLATION...9 2.1 Definitions on ETOR... 9 2.2 Configuring ETOR...10 2.3 Required Installations

More information

MODBUS AND BACNET COMMUNICATION INSTRUCTIONS

MODBUS AND BACNET COMMUNICATION INSTRUCTIONS 100275719_2000534455_Rev A MODBUS AND BACNET COMMUNICATION INSTRUCTIONS Power-Fin Models: 2500-5000 WARNING This manual must only be used by a qualified heating installer / service technician. Read all

More information

MSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays

MSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays ABB Application Note MSOC AN-64A-00 Substation Automation and Protection Division MSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays Introduction There seems to be some confusion with

More information

APPLICATION NOTE #xx. Modbus Installation and Troubleshooting for AP9635/AP9635CH Network Management Card By Gary Ware.

APPLICATION NOTE #xx. Modbus Installation and Troubleshooting for AP9635/AP9635CH Network Management Card By Gary Ware. [ APPLICATION NOTE #168 ] APPLICATION NOTE #xx Modbus Installation and Troubleshooting for AP9635/AP9635CH By Gary Ware PROJECT AT A GLANCE Project Type Modbus installation Applications Data centers with

More information

IntesisBox Modbus Server Panasonic

IntesisBox Modbus Server Panasonic IntesisBox Modbus Server - Panasonic Gateway for Panasonic ECO-i VRF and PAC-i system integration into Modbus Systems Master Up to 30 Outdoor units Up to 64 Indoor units Modbus TCP Master /EIA232 PA-AC-MBS-64/128

More information

EQ-DCM User Manual Revision 1.02 Sep 10, 2013

EQ-DCM User Manual  Revision 1.02 Sep 10, 2013 EQ-DCM User Manual www.equustek.com Revision 1.02 Sep 10, 2013 Contents INTRODUCTION...5 ABOUT THIS MANUAL... 5 INTENDED AUDIENCE... 5 HARDWARE SPECIFICATIONS...6 PHYSICAL SPECIFICATIONS... 6 HARDWARE

More information

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.6 4/25/20 20 CoolAutomation LTD. Attention 1. During the HVAC system automatic operations the CoolMasterNet must be disconnected

More information

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/ Rev. A 1/25/213 172 Contents Contents Temperature-Humidity Sensor Configuration Tool... 3 Read Sensor Screen... 3 Manual Calibration Screen... 4 Register View Screen... 5 Modbus Registers... 6 Reprogram

More information

IntesisBox Modbus Server - LON

IntesisBox Modbus Server - LON IntesisBox Server - LON Gateway for integration of LON devices into enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries,

More information

ICP PANEL-TEC PEX3000 II

ICP PANEL-TEC PEX3000 II ICP PANEL-TEC PEX3000 II MODBUS PORT EXPANDER INSTALLATION AND OPERATION GUIDE REVISION HISTORY Revision Date Author Comments 000 29 Aug 2008 Keira Majors Initial release. 001 16 Sep 2008 David Walker

More information

MGate 5111 Quick Installation Guide

MGate 5111 Quick Installation Guide MGate 5111 Quick Installation Guide Edition 1.0, December 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide VxI Power Ltd. IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide 01/12/2015 Document Number: 14970-020A Issue Number: 2 Contents 1.0 Device Overview... 2 2.0 Getting Started... 3 2.1 Connecting the Device...

More information

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017 DL-10 User Manual RS-485 Remote Temperature and Humidity English Ver. 1.0, Jul. 2017 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year from

More information

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc. MS1-2150 Protocol Converter User Manual Firmware version 2.0 ISI Instrumental Solutions, Inc. WWW.ISIDEV.NET Introduction The MS1-2150 protocol converter can take readings from 1 or more ModBus registers

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway Tiny Serial-to- Device Server & Modbus Gateway - Tiny Serial-to- Device Server & Modbus Gateway tds-00 Series NEW tds-12 tds-00 series Tiny Serial-to- Device Server Features Incorporates any /422/485 serial

More information

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server Fidelio IP IntesisBox Modbus Server Fidelio IP User Manual r1 eng Issue Date: 10/04/2014 Intesis Software S.L. All Rights Reserved. Information in this document is subject to change without notice. The software described

More information

W8735A1013 EnviraCOM Serial Adapter

W8735A1013 EnviraCOM Serial Adapter W8735A1013 EnviraCOM Serial Adapter INSTALLATION INSTRUCTIONS TABLE OF CONTENTS INSTALLATION... 2 When installing this product... 2 Selecting Location... 2 Mounting W8735A1013 EnviraCOM Serial Adapter...

More information

M1000 INTELLIGENT ZONE CONTROL SYSTEM

M1000 INTELLIGENT ZONE CONTROL SYSTEM HARDWARE GUIDE DIMENSIONS & SPECIFICATIONS REV. 5.2 M1000 INTELLIGENT ZONE CONTROL SYSTEM ROOFTOP CONTROLLER 2 Table of Contents GENERAL INFORMATION... 3 PL-M1000 Rooftop Controller...3 Description...3

More information

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...

More information